Elite.Parts chervon right Manufacturers chervon right M chervon right MAC VALVES chervon right 111B-871JB
About product Specifications Features Datasheet FAQ

MAC VALVES 111B-871JB

Image of MAC VALVES 111B-871JB

Description

Mac Valves 111B-871JB Valve. 1/8" NPTF | 24 V DC | 17.1 Watts | Non-locking | Rectangular connector | Modif: CLSF | VAC TO 150 PSI

Part Number

111B-871JB

Price

Request Quote

Manufacturer

MAC VALVES

Lead Time

Request Quote

Category

PRODUCTS - 1

Specifications

Coil

General purpose class A, continuous duty, encapsulated

Filtration

40 µ

Flow (at 6 bar, ?P-1bar)

0.18 Cv

Fluid

Compressed air, vacuum, inert gases

Lubrication

Not required, if used select a medium aniline point lubricant (between 180°F and 210°F)

Port Size

1/8” NPTF

Power

Inrush : 14.8 VA

Pressure range

Vacuum to 150 PSI

Protection

Consult factory

Temperature range

0°F to 140°F (-18°C to 60°C)

Voltage range

-15% to +10% of nominal voltage

Features

Datasheet

pdf file

Mac-Valves-111B-111CAAA-Solenoid-Valve-datasheet1-199944764.pdf

521 KiB

Extracted Text

Direct solenoid and solenoid pilot operated valves Series 100 Individual mounting Series inline 35 Manifold mounting sub-base stacking non “plug-in” 10 100 0 Manual operator 200 55 56 Sealed solenoid enclosure 57 58 59 Armature 45 Solenoid push pin 2 1 Spring biased moveable pole piece 700 CYL N.C. Poppet 3 N.O. 900 Valve spring 82 6300 SERIES FEATURES 6500 ® • The patented MACSOLENOID with its non-burn out feature on AC service. 6600 • Six valve functions with one individual valve. • Individual, stacking body & add-a-unit manifold base capability. 1300 • Use on lube or non-lube service. • Extremely rapid response and cycle rate. 800 • Various types of manual operators and electrical enclosures. • Extremely long service life. ISO 1 • Optional low wattage DC solenoids down to 1 watt. ISO 2 ISO 3 MAC 125A MAC 250A MAC 500A 23 Consult “Precautions” page 364 before use, installation or service of MAC Valves W WARRANTY ARRANTY 100% 100% 100% 100% OF OF PRODUCTION PRODUCTION TESTED TESTED 18 18 18 18 100% 100% 100% 100% MONTHS MONTHS Series 100 APPLICATION CONVERSION PROCEDURE: function plate is used for both N.C. and N.O. When "3-NC" is visible on the plate, the function will be N.C. When "3-NO" is visible, the function is N.O. On 2-way applications, INDIVIDUAL MODELS two separate plates are used-one for N.C., marked "2-NC"; the other for N.O., marked The balanced poppet design facilitates using the same valve for 6 functions with any port "2-NO". The 2-way plates block the exhaust at the valve, permitting the mixing in a being connected to vacuum, pressure or plugged. Piping is shown in the chart below. stack of 3-ways and 2-ways. Changes within a stack from one function to another can be made without disturbing the plumbing. STACKING BODY MODELS The interchangeable function plate between the valve bodies permits selection of either N.C. ONLY MODELS 3-way Normally Closed or 3-way Normally Open operation. A single purpose Normally Closed Only model is available for those applications where a greater tolerance for heavy concentrations of water, compressor products and other air MANIFOLD BASE MODELS line contaminants is desired. The interchangeable function plate between the valve bodies and base permits selection for 2- or 3-way, Normally Closed or Normally Open operation. On 3-way applications, one PIPING CHART FOR INDIVIDUAL MODELS 21 21 21 X 3 3 3 PLUGGED 3 Way 2 Way Selector Normally Closed Normally Closed P L 21 21 U 21 X G G E D 3 3 3 3 Way 2 Way Divertor Normally Open Normally Open Supply Operator De-Energized Operator Energized 24 24 Consult “Precautions” page 364 before use, installation or ser Consult “Precautions” page 364 before use, installation or service of MAC V vice of MAC Valves alves Direct solenoid and solenoid pilot operated valves Series 100 Function Port size Flow (Max) Individual mounting Series 3/2 NO-NC, 2/2 NO-NC 1/8” - 1/4” 0.18 C inline v OPERATIONAL BENEFITS 1. Balanced poppet, immune to variations of 35 pressure. 2. Short stroke with high flow. 3. The patented solenoid develops high shifting forces. 10 100 0 4. Powerful return spring. 5. Manual operator standard on all valves. 6. Burn-out proof solenoid on AC service. 200 55 56 HOW TO ORDER 57 58 Port size Universal valve NC only valve 59 2 2 13 13 1/8” NPTF 111B-XXYZZ 161B-XXYZZ 1/4” NPTF 113B-XXYZZ 163B-XXYZZ 45 * SOLENOID OPERATOR ³ XX Y ZZ XX Voltage Y Manual operator ZZ Electrical connection 700 11 120/60, 110/50 1 Non-locking JB Rectangular connector 12 240/60, 220/50 2 Locking JD Rectangular connector with light 22 24/60, 24/50 JA Square connector 900 59 24 VDC (2.5 W) JC Square connector with light 87 24 VDC (17.1 W) BA Flying leads (18”) 61 24 VDC (8.5 W) CA Conduit 1/2” NPS 82 * Other options available, see page 357. Notes: 6300 CHANGING FROM NORMALLY CLOSED TO NORMALLY OPEN Individual inline valves can be changed from normally closed to normally open by connecting the inlet to port 3 instead of port 1. NORMALLY CLOSED ONLY MODELS 6500 A single purpose Normally Closed only model is available for those applications where a greater tolerance for heavy concentrations of water, compressor products and other air line contaminants is desired. Model numbers are indicated above. 6600 1300 800 ISO 1 ISO 2 ISO 3 MAC 125A MAC 250A MAC 500A 25 Consult “Precautions” page 364 before use, installation or service of MAC Valves GARANTIE 100% 100% D E L A P R O D U C T I O N T E S T É E 18 18 100% 100% M O I S WARRANTY 100% 100% O F P R O D U C T I O N T E S T E D 18 18 100% 100% M O N T H S Series 100 technical data Fluid : Compressed air, vacuum, inert gases Pressure range : Vacuum to 150 PSI Lubrication : Not required, if used select a medium aniline point lubricant (between 180°F and 210°F) Filtration : 40 µ temperature range : 0°F to 140°F (-18°C to 60°C) Flow (at 6 bar, ∆P=1bar) : 0.18 C v Leak rate : Coil : General purpose class A, continuous duty, encapsulated Voltage range : -15% to +10% of nominal voltage Protection : Consult factory Power : ∼ Inrush : 14.8 VA Holding : 10.9 VA = 1 to 17 W response times : 24 VDC (8.5 W ) Energize : 7 ms De-energize : 2 ms 120/60 Energize : 3-8 ms De-energize : 2-7 ms Spare parts : • Solenoid operator (power ≥ 4 W) : D1-XXAA, cover mounting screws 32184 and seal 16234. Options : • BSPP threads. Dimensions shown are metric (mm) dimensions 89,0 72,4 24,6 Ø 5 mm 56,0 16,8 F #2 #1 ~48 17,8 G 3 4,1 H 2 1 #3 C D ø 18 24,9 B 22,2 21,2 33,0 A Ø 4,4 mm PORT SIZE A B C D E F G H 1/8” 28.4 12.7 14.0 8.0 40.1 64.9 60.1 23.2 1/4” 29.8 13.3 12.7 9.9 40.9 65.8 60.9 24.1 26 Consult “Precautions” page 364 before use, installation or service of MAC Valves Direct solenoid and solenoid pilot operated valves Series 100 Function Port size Flow (Max) Manifold mounting Series 3/2 NO-NC, 2/2 NO-NC 1/8” - 1/4” 0.18 C stacking v OPERATIONAL BENEFITS 1. Balanced poppet, immune to variations of 35 pressure. 2. Short stroke with high flow. 3. The patented solenoid develops high shifting forces. 10 100 0 4. Powerful return spring. 5. Manual operator standard on all valves. 6. Burn-out proof solenoid on AC service. 200 55 56 HOW TO ORDER 57 Port size Universal valve NC only valve 58 59 2 2 13 13 1/8” NPTF 181B-XXYZZ 184B-XXYZZ 1/4” NPTF 183B-XXYZZ 185B-XXYZZ 45 * ³ SOLENOID OPERATOR XX Y ZZ XX Voltage Y Manual operator ZZ Electrical connection 700 11 120/60, 110/50 1 Non-locking JB Rectangular connector 12 240/60, 220/50 2 Locking JD Rectangular connector with light 22 24/60, 24/50 BA Flying leads (18”) 59 24 VDC (2.5 W) MB Common conduit 1” NPS 900 87 24 VDC (17.1 W) 61 24 VDC (8.5 W) 82 * Other options available, see page 357. End plate kit required (Port size 1/4”) : M-01001-01 “MB” option also requires end plate kit: M-01002-01 6300 Notes: 6500 CHANGING FROM NORMALLY CLOSED TO NORMALLY OPEN In the case of stacking valves a reversible plate, complete with indicator, is placed between each valve body assembly. This determines whether the valve is N.C. or N.O. 6600 NORMALLY CLOSED ONLY MODELS A single purpose Normally Closed only model is available for those applications where a greater tolerance for heavy concentrations of water, 1300 compressor products and other air line contaminants is desired. Model numbers are indicated above. 800 ISO 1 ISO 2 ISO 3 MAC 125A MAC 250A MAC 500A 27 Consult “Precautions” page 364 before use, installation or service of MAC Valves GARANTIE 100% 100% D E L A P R O D U C T I O N T E S T É E 18 18 100% 100% M O I S WARRANTY 100% 100% O F P R O D U C T I O N T E S T E D 18 18 100% 100% M O N T H S Series 100 technical data Fluid : Compressed air, vacuum, inert gases Pressure range : Vacuum to 150 PSI Lubrication : Not required, if used select a medium aniline point lubricant (between 180°F and 210°F) Filtration : 40 µ temperature range : 0°F to 140°F (-18°C to 60°C) Flow (at 6 bar, ∆P=1bar) : 0.18 C v 3 Leak rate : 100 cm /min Coil : General purpose class A, continuous duty, encapsulated Voltage range : -15% to +10% of nominal voltage Protection : Consult factory Power : ∼ Inrush 14.8 VA Holding : 10.9 VA DC : 1 to 17.1 W response times : 24 VDC (8.5 W) Energize : 7 ms De-energize : 2 ms 120/60 Energize : 3-8 ms De-energize : 2-7 ms Spare parts : •-Solenoid operator (power ≥ 4 W) : D1-XXAA, cover mounting screws 35206 and seal 16234. • Function plate : N-01002. • Tie-rod (x2) : 19674. • Inlet isolator plate : N01003. • Exhaust isolator plate : N01004. Options : • BSPP threads. • Bottom inlet (Mod. 0210). Dimensions shown are metric (mm) dimensions 1/4” INLET & EXHAUST PORTS EACH END CYL. PORT 1/8” OR 1/4” MT’G SLOT Ø 6,6 mm 1/8” - OPTIONAL BOTTOM INLET PORTS 28 Consult “Precautions” page 364 before use, installation or service of MAC Valves Direct solenoid and solenoid pilot operated valves Series 100 Function Port size Flow (Max) Manifold mounting Series sub-base 3/2 NO-NC, 2/2 NO-NC 1/8” 0.14 C v non “plug-in” OPERATIONAL BENEFITS 1. Balanced poppet, immune to variations of 35 pressure. 2. Short stroke with high flow. 3. The patented solenoid develops high shifting forces. 10 100 0 4. Powerful return spring. 5. Manual operator standard on all valves. 6. Burn-out proof solenoid on AC service. 200 55 56 HOW TO ORDER 57 Port size Universal valve NC only valve 58 59 2 2 13 13 Valve less base 130B-XXYZZ 170B-XXYZZ 1/8” base NPTF 132B-XXYZZ 172B-XXYZZ 45 * ³ SOLENOID OPERATOR XX Y ZZ XX Voltage Y Manual operator ZZ Electrical connection 700 11 120/60, 110/50 1 Non-locking JB Rectangular connector 12 240/60, 220/50 2 Locking JD Rectangular connector with light 22 24/60, 24/50 BA Flying leads (18”) 900 59 24 VDC (2.5 W) MA Common conduit 1” NPS 87 24 VDC (17.1 W) RA Conduit 3/8” NPS 61 24 VDC (8.5 W) 82 * Other options available, see page 357. End plate kit required (Port size : 1/4” ) : A2-5004-01 “MA” option also requires end plate kit : M-01002-01 6300 OPTIONS 6500 12XB-XXYZZ 2-way N.C. 6600 14XB-XXYZZ 1300 2-way N.O. 102 800 (Base only) Notes: ISO 1 CHANGING FROM NORMALLY CLOSED TO NORMALLY OPEN For manifold base mounted valves a plate is provided between the valve and the base. Three plates are available; a reversible plate for 3 Way valves (N.C. & ISO 2 N.O.), one plate for 2 Way N.C. and one for 2 Way N.O. Appropriate plates, determined by the valve model number, are supplied automatically with the valve. ISO 3 NORMALLY CLOSED ONLY MODELS A single purpose Normally Closed only model is available for those applications where a greater tolerance for heavy concentrations of water, compressor MAC 125A products and other air line contaminants is desired. Model numbers are indicated above. MAC 250A MAC 500A 29 Consult “Precautions” page 364 before use, installation or service of MAC Valves GARANTIE 100% 100% D E L A P R O D U C T I O N T E S T É E 18 18 100% 100% M O I S WARRANTY 100% 100% O F P R O D U C T I O N T E S T E D 18 18 100% 100% M O N T H S Series 100 technical data Fluid : Compressed air, vacuum, inert gases Pressure range : Vacuum to 150 PSI Lubrication : Not required, if used select a medium aniline point lubricant (between 180°F and 210°F) Filtration : 40 µ temperature range : 0°F to 140°F (-18°C to 60°C) Flow (at 6 bar, ∆P=1bar) : 0.14 C v Leak rate : Coil : General purpose class A, continuous duty, encapsulated Voltage range : -15% to +10% of nominal voltage Protection : Consult factory Power : ∼ Inrush : 14.8 VA Holding : 10.9 VA = 1 to 17 W response times : 24 VDC (8.5 W) Energize : 7 ms De-energize : 2 ms 120/60 Energize : 3-8 ms De-energize : 2-7 ms Spare parts : •-Solenoid operator (power ≥ 4 W) : D1-XXAA, cover mounting screws 32184 and seal 16234. • Function plate : A2-7009. • Seal between manifold bases : 16226. • Tie-rod (x2) : 19546. Options : • BSPP threads. • Isolation of inlet : Mod. 313P. • Isolation of exhaust : Mod. 313E. • Additional bottom inlet : Mod. 0210. • Bottom cyl. port : Mod. 0009. • All bottom & side ports : Mod. 0004. Note : • Specify mod. number after valve model number (i.e. 132B-111BA Mod. 0210) Dimensions shown are metric (mm) dimensions 1/8” CYL. PORT OPTIONAL 1/8” BOTTOM PORTS 1/4” INLET & EXHAUST PORTS EACH END MT’G SLOT Ø 6,6 mm 30 Consult “Precautions” page 364 before use, installation or service of MAC Valves Intrinsically Safe Valves Series 100 HOW TO ORDER BODY OPTIONS 1 X X B - (XXYZZ) - FM - SOLENOID OPTIONS SEE BELOW SERIES REVISION LEVEL VALVE FUNCTION PORT SIZE/BODY STYLE 6 N.C. only ind. inline 0 Manifold valve less base 7 N.C. only manifold 1 1/8" NPTF ind.inline 8 Stacking body 2 1/8" NPTF manifold 3 1/4" NPTF ind.inline 4 1/8" NPTF stacking, 3-way N.C. only 5 1/4" NPTF stacking, 3-way N.C. only 6 1/8" BSPP inline 7 1/4" BSPP inline 8 1/8" BSPP stacking, 3-way N.C. only 9 1/4" BSPP stacking, 3-way N.C. only SOLENOID OPTIONS EXAMPLE : XX Y ZZ - FM XX DC VOLTAGE Y MANUAL OPERATOR ZZ ENCLOSURE AA JIC w/1/2" NPS Conduit A5 12 VDC (0.6 W) 0 No operator A6 24 VDC (0.6 W) 1 Non-locking Recessed (std.) BA Grommet CA Conduit 1/2" NPS 2 Locking Recessed 3 Non-locking Extended CC Conduit 1/2" NPT (CSA threads) JB Rectangular Plug-in 4 Locking Extended JM Rectangular Male only NA Conduit 1/2" NPS w/ground wire RA Conduit 3/8" NPS for Manifold models MA Com. Conduit 1" NPS (Manifold models) MB Com. Conduit 1" NPS (Stacking models) (MA & MB common conduit covers require 1#M-01002-01 conduit end plate kit per stack) STACKING BODY ACCESSORIES : 100 SERIES-SUPPLEMENTAL TECHNICAL DATA STACKING END PLATE KIT- For each gang one kit is required. MOD. NO. DESCRIPTION MODEL AVAILABILITY TO ORDER- Specify number M-01001-01 0004 All bottom and side ports Manifold models only (1/4" NPTF) 0009 Bottom and side cylinder ports with Manifold models only or M-01001-01P side only inlet and exhaust ports (1/4" BSPP). 0210 Additionnal bottom inlet Manifold & stacking models INLET ISOLATOR PLATE N-01003 313P For isolating the common inlet Manifold models only EXHAUST ISOLATOR PLATE N-01004 passage between manifold bases 313E For isolating the common exhaust Manifold models only MANIFOLD ACCESSORIES : passage between manifold bases MANIFOLD END PLATE KIT- For each gang one kit is required. TO ORDER Add the appropriate modification number from the table above after the valve number, TO ORDER- Specify number A2-5004-01 EXAMPLE : 172B-A51BA-FM MOD 0004. (1/4" NPTF) or A2-5004-01P (1/4" BSPP). 343 Consult “Precautions” page 364 before use, installation or service of MAC Valves O p t i o n s OPTIONS Codification table for voltages / Manual operator / Electrical connection / Wire length ³ VALVE CODE - XX Y ZZ (-VV) 1 2 3 4 OPTIONS AVAILABLE FOR OPTIONS AVAILABLE FOR - valves type 100 Series - valves type 200 Series - pilot valves "CNOMO" - Pilot operated valves with pilots type 100 Series - pilot operated valves with pilots type 200 Series Series : 55 - 56 - 700 - 800 - 900 Series : 200 - 57 - 58 - 59. - 6300 - 6500 - 6600 - 1300 - ISO 1 - ISO 2 - ISO 3. - MAC 125 - MAC 250 - MAC 500 - Pilot operated valves with pilots "CNOMO" Series : ISO1 - ISO2 - ISO3 357 Consult “Precautions” page 364 before use, installation or service of MAC Valves OPTIONS Used on valve series: 100, 55, 56, 700, 800, 900, 6300, 6500, 6600, 1300, MVA1C, Used on valve series: 200, 57, 58, 59. MVA2B, MVA3B, MAC125, MAC250, MAC500. 1. VOLTAGE (100 Serie type coil) 1. VOLTAGE (200 Serie type coil) - XX Y ZZ VOLTAGE - XX Y ZZ VOLTAGE 11 120/60, 110/50 11 120/60, 110/50, 24 VDC (6 W) 12 240/60, 220/50 12 240/60, 220/50 13 100/60, 100/50 13 100/60, 100/50 15 200/60, 200 /50 14 200/60, 200/50 16 10/60 20 6/60 20 6/60 21 12/60 21 12/50, 12/60 22 24/60, 24/50 22 24/60, 24/50 23 32/60, 32/50 23 32/60, 32/50 24 48/60, 42/50 24 48/60, 42/50 25 240/50 26* 380/50, 440/50, 440/60, 480/60 26 480/60, 440/50 29 220/60 27 127/60 34 127/50, 120/50 28 415/50 35 48/50 29 220/60 36 16/60 30 380/50 B1 24/50 31 550/60, 550/50 50 24 VDC (6 W) 32 120/60, 110/50 51 24 VDC (4 W) 33 600/60 54 12 VDC (4 W) 34 127/50 55 12 VDC (6 W) 35 48/50 57 12 VDC (2.5 W) 50 24 VDC (6 W) 59 24 VDC (2.5 W) 51 24 VDC (4.5 W) 60 12 VDC (8.5 W) 52 24 VDC (2.5 W) 61 24 VDC (8.5 W) 53 24 VDC (1.0 W) 64 6 VDC (6 W) 55 12 VDC (6 W) 65 32 VDC (7 W) 57 12 VDC (2.5 W) 66 48 VDC (5.8 W) 58 48 VDC (2.5 W) 67 64 VDC (7.5 W) 60 12 VDC (9.5 W) 68 120 VDC (6.4 W) 61 24 VDC (8.5 W) 69* 220 VDC (8.7 W), 250 VDC (11.2 W) 64 6 VDC (8.5 W) 75 90 VDC (8.8 W) 65 32 VDC (10 W) 76* 100 VDC (6.9 W) 66 48 VDC (11.5 W) 84* 125 VDC (10.9 W) 67 64 VDC (10.5 W) 87* 24 VDC (17.1 W) 68 120 VDC (12.3 W) 88* 12 VDC (17.4 W) 69 250 VDC (9.2 W) 89* 36 VDC (18.8 W) 71 8 VDC (8.2 W) 90 28 VDC (8.2 W) 72 24 VDC (12 W) 91* 6 VDC (10.6 W) 73 198 VDC (10 W) 92 190 VDC (6.5 W) 74 72 VDC (11.3 W) 94 3 VDC (7 W) 75 90 VDC (11.3 W) 95 38 VDC (6.4 W) 76 100 VDC (9 W) A1 24 VDC (1 W) 77 220 VDC (10 W), 230 VDC (11.6 W) A2 12 VDC (1 W) 78* 24 VDC (24 W) A3 9 VDC (1 W) 80 55 VDC (10.6 W) MOD. DD01 : Protection diode (DC) - MAX. 8.5W 82 170 VDC (11.1 W) MOD. MOV1 : Protection varistor (AC) - MAX. 8.5W 83 15 VDC (8.1 W) * Voltages are CLSF only 84 125 VDC (10 W) 86 36 VDC (11 W) 93* 12 VDC (24 W) 358 Consult “Precautions” page 364 before use, installation or service of MAC Valves O p t i o n s OPTIONS 2. MANUAL OPERATOR (Common options for 100 & 200 Series type coils) - XX Y ZZ MANUAL OPERATOR 0 No operator 5* No Operator with Light 1 Non-locking recessed 6* Non-Locking Recessed with Light 2 Locking recessed 7* Locking Recessed with Light 3 Non-locking extended 8* Non-Locking Extended with Light 4 Locking extended 9* Locking Extended with Light * Lights used with “AA” electrical connection 3. ELECTRICAL CONNECTION (100 Serie type coil) 3. ELECTRICAL CONNECTION (200 Serie type coil) - XX Y ZZ ELECTRICAL CONNECTION - XX Y ZZ ELECTRICAL CONNECTION AA Wiring box with 1/2" NPS conduit AA Wiring box with 1/2" NPS conduit BA Flying leads BA Flying leads CA 1/2" NPS conduit CA 1/2" NPS conduit CC 1/2" NPT conduit CC 1/2" NPT conduit FA Military type 2 PIN EA Explosion proof (200 Series) GA Military type 3 PIN EA Explosion proof (57, 58 & 59 Series) HA AA with ground wire FA Military type 2 PIN JA* Square connector GA Military type 3 PIN JB Rectangular connector HA AA with ground wire JC* Square connector with light JA* Square connector JD Rectangular connector with light JC Square connector with light JE Square connector on top JJ Square connector, male only (ISO2, ISO3) NA CA with ground wire JF Rectangular connector on top NC CC with ground wire (ISO1, ISO2, ISO3) JG JE with light JH JF with light JJ Square connector, male only JM Rectangular connector, male only MA Electrical common conduit (100 Series-Manifold/900 Series) MB Electrical common conduit (100 Series-Stacking/700 Series) NA CA with ground wire NC CC with ground wire RA 3/8" NPS conduit * Not to be used with 100, 800 and 900 Series manifold mounting 359 Consult “Precautions” page 364 before use, installation or service of MAC Valves OPTIONS 4. COIL WIRE LENGTH (Common options for 100 & 200 Serie type coils) - XX Y ZZ (-VV) WIRE LENGTH AA 18” AB 24” AD 36” AE 48” AF 72” AG 6” AR 12” AU 120” BA 60” BB 144” Series 6000 : wire length, from the base MOD L024 24” MOD L036 36” MOD L048 48” MOD L060 60” MOD L072 72” MOD L120 120” 360 Consult “Precautions” page 364 before use, installation or service of MAC Valves

Frequently asked questions

What makes Elite.Parts unique?

chervon down
At GID Industrial (Elite.Parts' parent company), we specialize in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

What kind of warranty will the 111B-871JB have?

chervon down
Warranties differ by part and by which suppliers we use to procure it for you. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carriers does Elite.Parts work with?

chervon down
Elite.Parts can ship via FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Will Elite.Parts sell to me even though I live outside the USA?

chervon down
Absolutely! We are happy to serve customers regardless of location. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

I have a preferred payment method. Will Elite.Parts accept it?

chervon down
All major credit cards are accepted: Visa, MasterCard, Discover, and American Express. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

Mac Valves 100 Series Direct Solenoid and Solenoid Pilot Operated Valves, 3/2 - 2/2 Function, G1/8” ...

product

MAC Valves 1113A111 Valve - 3WAY Pneumatic Valve

product

Mac Valves 111B-111BAAA Valve - VALVE AIR SOLENOID 120VAC 150PSI

product

Mac Valves 111B111CA Valve 120/60 110/50VAC non-locking operator

product

Mac Valves 111B-111CAAA Solenoid Valve. 120V AC

product

Mac Valves 111B-111JA Series 100 Solenoid Pilot Operated Valve, 1/8” NPTF 120/60, 110/50 Non-locking...