M-SYSTEMS W2SP
Specifications
Accuracy
±0.1 % (output 10 – 100 %)
Approx. 0.5 sec. with 0 – 10 kHz;
Performance
Connection
M3 screw terminals (torque 0.8 N•m)
Construction
Plug-in
Dielectric strength
2000 V AC @1 minute (input to output 1 to output 2 to power to ground)
Housing material
Flame-resistant resin (black)
Input filter
Provided with input range
Input pulse sensing
DC coupled; detecting pulse rise
Insulation resistance
Greater than 100 M Omega with 500 V DC
Isolation
Input to output 1 to output 2 to power
Line voltage effect
±0.1 % over voltage range
Low-end cutout
2 to 5 %
Mounting
Surface or DIN rail
Operating humidity
30 to 90 %RH (non-condensing)
Operating temperature
-5 to +55°C (23 to 131°F)
Over-range output
0 to 120 % at 1 – 5 V
Power Consumption AC
Approx. 5 VA at 100 V; Approx. 6 VA at 200 V; Approx. 7 VA at 240 V
Power Consumption DC
Approx. 3 W
Response time
(0 – 90%) Approx. 1.8 sec. with 0 – 50 Hz; Approx. 0.7 sec. with 0 – 100 Hz; Approx. 0.5 sec. with 0 – 500 Hz
Ripple
0.2 %p-p max. With input = 10 %
Span adjustment
95 to 105 % (front)
Temp. coefficient
±0.015 %/°C (±0.008 %/°F)
Weight
200 g (0.44 lbs)
Zero adjustment
-5 to +5 % (front)
Features
- 2000V AC isolation
- Base socket included with modules
- CE marking and UL/C-UL Class 1 Div 2 approval
- Converts the output from a pulse-type transducer into a standard process signal
- Fixed range or PC programmable models selectable
- Selectable 100-240V AC/24V DC power input
- Standard DIN rail or surface mounting
- W2 use a compact-size, plug-in socket base for quick installation or replacement of modules without disturbing wiring.
Datasheet
Extracted Text
Model ZERO SPAN ZERO SPAN MODEL: W2SP E: 0 – 16 mA DC (Load resistance 900 Ω max.) Space-saving Dual Output Signal Conditioners F: 0 – 10 mA DC (Load resistance 1500 Ω max.) Mini-MW Series G: 0 – 1 mA DC (Load resistance 15 kΩ max.) Z: Specify current (See OUTPUT SPECIFICATIONS) LOW FREQUENCY TRANSMITTER Voltage (50 Hz minimum) 1: 0 – 10 mV DC (Load resistance 10 kΩ min.) Functions & Features 2: 0 – 100 mV DC (Load resistance 100 kΩ min.) • Converts the output from a pulse-type transducer 3: 0 – 1 V DC (Load resistance 1000 Ω min.) into a standard process signal 4: 0 – 10 V DC (Load resistance 10 kΩ min.) • CE marking 5: 0 – 5 V DC (Load resistance 5000 Ω min.) • UL approval 6: 1 – 5 V DC (Load resistance 5000 Ω min.) 4W: -10 – +10 V DC (Load resistance 10 kΩ min.) Typical Applications 5W: -5 – +5 V DC (Load resistance 5000 Ω min.) • Positive displacement flowmeters, turbine flowmeters and 0: Specify voltage (See OUTPUT SPECIFICATIONS) vortex flowmeters • Proximity switches [3] OUTPUT 2 Y: None 29.5 (1.16) Current A: 4 – 20 mA DC (Load resistance 350 Ω max.) B: 2 – 10 mA DC (Load resistance 700 Ω max.) 89 C: 1 – 5 mA DC (Load resistance 1400 Ω max.) (3.51) D: 0 – 20 mA DC (Load resistance 350 Ω max.) E: 0 – 16 mA DC(Load resistance 430 Ω max.) F: 0 – 10 mA DC (Load resistance 700 Ω max.) 124 (4.88) G: 0 – 1 mA DC (Load resistance 7000 Ω max.) mm (inch) Z: Specify current (See OUTPUT SPECIFICATIONS) Voltage Same range availability as Output 1 MODEL: W2SP–[1][2][3]-[4][5] [4] POWER INPUT ORDERING INFORMATION AC Power • Code number: W2SP-[1][2][3]-[4][5] M2: 100 – 240 V AC (Operational voltage range 85 – 264 V, Specify a code from below for each [1] through [5]. 47 – 66 Hz) (e.g. W2SP-1AA-M2/CE/Q) (90 – 264 V for UL) • Frequency range (e.g. 0 – 10 kHz) DC Power • Special output ranges (For codes Z & 0) R: 24 V DC • Specify the specification for option code ‘Q.’ (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) (e.g. /C01/S01) R2: 11 – 27 V DC Note: If one of the outputs should be a current range, (Operational voltage range 11 – 27 V, ripple 10 %p-p max.) specify it for the Output 1 to allow a greater load. (Select ‘/N’ for ‘Standards & Approvals’ code.) P: 110 V DC [1] INPUT (Operational voltage range 85 – 150 V, ripple 10 %p-p max.) 1: Dry contact (110 V ±10 % for UL) 2: Voltage pulse [5] OPTIONS (multiple selections) [2] OUTPUT 1 Standards & Approvlas (must be specified) Current /N: Without CE or UL A: 4 – 20 mA DC (Load resistance 750 Ω max.) /CE: CE marking B: 2 – 10 mA DC (Load resistance 1500 Ω max.) /UL: UL approval, CE marking C: 1 – 5 mA DC (Load resistance 3000 Ω max.) Other Options D: 0 – 20 mA DC (Load resistance 750 Ω max.) blank: none http://www.m-system.co.jp/ W2SP SPECIFICATIONS ES-5502 Rev.7 Page 1/3 MODEL: W2SP /Q: Option other than the above (specify the specification) INSTALLATION (UL not available) Power Consumption •AC: Approx. 5 VA at 100 V SPECIFICATIONS OF OPTION: Q (multiple selections) Approx. 6 VA at 200 V COATING (For the detail, refer to M-System's web site.) Approx. 7 VA at 240 V /C01: Silicone coating •DC: Approx. 3 W /C02: Polyurethane coating Operating temperature: -5 to +55°C (23 to 131°F) /C03: Rubber coating Operating humidity: 30 to 90 %RH (non-condensing) TERMINAL SCREW MATERIAL Mounting: Surface or DIN rail /S01: Stainless steel Weight: 200 g (0.44 lbs) GENERAL SPECIFICATIONS PERFORMANCE in percentage of span Construction: Plug-in Accuracy: ±0.1 % (output 10 – 100 %) Connection: M3 screw terminals (torque 0.8 N·m) Temp. coefficient: ±0.015 %/°C (±0.008 %/°F) Housing material: Flame-resistant resin (black) Response time: (0 – 90%) Isolation: Input to output 1 to output 2 to power Approx. 1.8 sec. with 0 – 50 Hz Overrange output: 0 to 120 % at 1 – 5 V Approx. 0.7 sec. with 0 – 100 Hz Zero adjustment: -5 to +5 % (front) Approx. 0.5 sec. with 0 – 500 Hz Span adjustment: 95 to 105 % (front) Approx. 0.5 sec. with 0 – 10 kHz Input pulse sensing: DC coupled; detecting pulse rise Ripple: 0.2 %p-p max. with input ≥ 10 % Input filter: Provided with input range <100 Hz Line voltage effect: ±0.1 % over voltage range (time constant approx. 1 msec.) Insulation resistance: ≥ 100 MΩ with 500 V DC Low-end cutout: 2 to 5 % Dielectric strength: 2000 V AC @1 minute (input to output 1 to output 2 to power to ground) INPUT SPECIFICATIONS Excitation: 12 V DC @30 mA; shortcircuit protection STANDARDS & APPROVALS Frequency range: 0 – 50 Hz through 10 kHz CE conformity: ■ Dry Contact: Mechanical contact or open collector EMC Directive (2004/108/EC) Pulse width time requirement: 20 μsec. min. for ON and OFF EMI EN 61000-6-4: 2007 Sensing: Approx. 12 V DC @3 mA EMS EN 61000-6-2: 2005 ON/OFF level: ≤ 200 Ω / 0.6 V for ON, ≥ 100 kΩ / 6 V for OFF Low Voltage Directive (2006/95/EC) ■ Voltage Pulse: Square or sine waveforms EN 61010-1: 2001 Pulse width time requirement: 20 μsec. min. for high and Installation Category II low levels Pollution Degree 2 Hi level: 2 – 50 V Input or output 1 or output 2 to power input: Lo level: ≤ 1 V Reinforced insulation (300 V) Input impedance: 10 kΩ min. Input to output 1 to output 2: Basic insulation (300 V) Approval: OUTPUT SPECIFICATIONS UL/C-UL nonincendive Class I, Division 2, ■ DC Current: 0 – 20 mA DC Groups A, B, C, and D hazardous locations Minimum span: 1 mA (UL 1604:2004, CAN/CSA-C22.2 No.213:1987) Offset: Max. 1.5 times span UL/C-UL general safety requirements Load resistance: Output drive 15 V max. for Output 1; (UL 61010B-1:2003, CAN/CSA-C22.2 No.61010-1:1992) 7 V max. for Output 2 ■ DC Voltage: -10 – +12 V DC (up to 10 V for Output 2) Minimum span: 5 mV Offset: Max. 1.5 times span Load resistance: Output drive 1 mA max.; at ≥ 0.5 V http://www.m-system.co.jp/ W2SP SPECIFICATIONS ES-5502 Rev.7 Page 2/3 MODEL: W2SP DIMENSIONS unit: mm (inch) 6 (.23) DIN RAIL 3 2 1 35mm wide 6 5 4 2–4.2x5 (.17x.20) MTG HOLE 6 (.24) deep 9 8 7 11–M3 SCREW 11 10 22 (.87) 29.5 (1.16) 23 (.91) 10 (.39) 84 (3.31) 114 (4.49) [4 (.16)] When mounting, no extra space is needed between units. SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM Z S Isolation Waveform Output + 1 One-Shot Smoother 7 + Shaper Driver INPUT OUTPUT 1 – 2 8 – SENSOR EXC. Z S + 4 12V Supply Output + 3 Driver 5 OUTPUT 2 – 6 9 10 U(+) POWER 11 V(–) Base Socket Remark: The section enclosed by broken line is only with 2nd output option. Input Connection Examples � Dry Contact � Voltage Pulse + + 1 1 – – 2 2 – – +12V +12V PWR PWR + + 4 4 4kΩ Specifications are subject to change without notice. http://www.m-system.co.jp/ W2SP SPECIFICATIONS ES-5502 Rev.7 Page 3/3 89 (3.50) 53 (2.09) 59 (2.32) 72 (2.83) 4 (.16)
Frequently asked questions
What makes Elite.Parts unique?

What kind of warranty will the W2SP have?

Which carriers does Elite.Parts work with?

Will Elite.Parts sell to me even though I live outside the USA?

I have a preferred payment method. Will Elite.Parts accept it?

Why buy from GID?

Quality
We are industry veterans who take pride in our work

Protection
Avoid the dangers of risky trading in the gray market

Access
Our network of suppliers is ready and at your disposal

Savings
Maintain legacy systems to prevent costly downtime

Speed
Time is of the essence, and we are respectful of yours
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods