M-SYSTEMS W2RS
Specifications
AC Power input
Approx. 4 VA at 100 V; Approx. 5 VA at 200 V; Approx. 6 VA at 240 V
Accuracy
±0.2 %
Burnout
Upscale standard; downscale optional
Burnout response
Greater than 10 sec.
Connection
M3 screw terminals (torque 0.8 N•m)
Construction
Plug-in
DC Power input
Approx. 3 W
Dielectric strength
2000 V AC @1 minute (input to output 1 to output 2 to power to ground)
Housing material
Flame-resistant resin (black)
Insulation resistance
Greater than 100 M Omega with 500 V DC
Isolation
Input to output 1 to output 2 to power
Line voltage effect
±0.1 % over voltage range
Linearization
Standard (not available for the input code C)
Mounting
Surface or DIN rail
Operating humidity
30 to 90 %RH (non-condensing)
Operating temperature
-5 to +55°C (23 to 131°F)
Over-range output
Approx. -10 to +120 % at 1 – 5 V
Span adjustment
95 to 105 % (front)
Temp. coefficient
±0.015 %/°C (±0.008 %/°F)
Weight
200 g (0.44 lbs)
Zero adjustment
-5 to +5 % (front)
Features
- “Active bridge” circuit containing two constant current sources allows large leadwire resistances up to 200 O
- 2000V AC isolation
- Accepts direct input from an RTD
- Base socket included with modules
- Burnout
- CE marking and UL/C-UL Class 1 Div 2 approval
- Fast response type available
- Fixed range or PC programmable models selectable
- Linearization
- Selectable 100-240V AC/24V DC power input
- Standard DIN rail or surface mounting
- W2 use a compact-size, plug-in socket base for quick installation or replacement of modules without disturbing wiring.
Datasheet
Extracted Text
Model ZERO SPAN ZERO SPAN MODEL: W2RS Space-saving Dual Output Signal Conditioners [1] INPUT RTD (2- or 3-wire) 1: JPt 100 (JIS'89) Mini-MW Series (Usable range: -200 to +500°C, -328 to +932°F; min.span: 50°C, 90°F) 3: Pt 100 (JIS'89) RTD TRANSMITTER (Usable range: -200 to +650°C, -328 to +1202°F; min.span: 50°C, 90°F) Functions & Features 4: Pt 100 (JIS'97, IEC) • Accepts direct input from an RTD (Usable range: -200 to +650°C, -328 to +1202°F; min.span: 50°C, 90°F) • Linearization 5: Pt 50 Ω (JIS'81) • Burnout (Usable range: -200 to +500°C, -328 to +932°F; min.span: 100°C, 180°F) • “Active bridge” circuit containing two constant current 6: Ni 508.4 Ω sources allows large leadwire resistances up to 200 Ω (Usable range: -50 to +200°C, -58 to +392°F; min.span: 30°C, 54°F) • Fast response type available C: Cu (Refer to ‘Cu INPUT’.) • CE marking 0: Specify • UL approval [2] OUTPUT 1 Typical Applications Current • Long distance transmission between the RTD and the A: 4 – 20 mA DC (Load resistance 750 Ω max.) transmitter B: 2 – 10 mA DC (Load resistance 1500 Ω max.) • Combination with intrinsic safety barriers C: 1 – 5 mA DC (Load resistance 3000 Ω max.) D: 0 – 20 mA DC (Load resistance 750 Ω max.) 29.5 (1.16) E: 0 – 16 mA DC (Load resistance 900 Ω max.) F: 0 – 10 mA DC (Load resistance 1500 Ω max.) G: 0 – 1 mA DC (Load resistance 15 kΩ max.) 89 Z: Specify current (See OUTPUT SPECIFICATIONS) (3.51) Voltage 1: 0 – 10 mV DC (Load resistance 10 kΩ min.) 2: 0 – 100 mV DC (Load resistance 100 kΩ min.) 124 (4.88) 3: 0 – 1 V DC (Load resistance 1000 Ω min.) mm (inch) 4: 0 – 10 V DC (Load resistance 10 kΩ min.) 5: 0 – 5 V DC (Load resistance 5000 Ω min.) 6: 1 – 5 V DC (Load resistance 5000 Ω min.) MODEL: W2RS–[1][2][3]-[4][5] 0: Specify voltage (See OUTPUT SPECIFICATIONS) ORDERING INFORMATION [3] OUTPUT 2 • Code number: W2RS-[1][2][3]-[4][5] Y: None Specify a code from below for each [1] through [5]. Current ((e.g. W2RS-4A6-M2/BL/CE/Q) A: 4 – 20 mA DC (Load resistance 350 Ω max.) • Temperature range (e.g. 0 – 500°C) B: 2 – 10 mA DC (Load resistance 700 Ω max.) • Special output ranges (For codes Z & 0) C: 1 – 5 mA DC (Load resistance 1400 Ω max.) • Specify the specification for option code ‘Q.’ D: 0 – 20 mA DC (Load resistance 350 Ω max.) (e.g. /C01/V01) E: 0 – 16 mA DC(Load resistance 430 Ω max.) For the input code C, specify also the following. If not F: 0 – 10 mA DC (Load resistance 700 Ω max.) specified, Cu 10 Ω @25°C (usable range -200 – +260°C) will G: 0 – 1 mA DC (Load resistance 7000 Ω max.) be used. Z: Specify current (See OUTPUT SPECIFICATIONS) • Input type (e.g. Cu 10 Ω) Voltage • Resistance range (e.g. 9.038 – 12.891 Ω) Same range availability as Output 1 Note: If one of the outputs should be a current range, specify it for the Output 1 to allow a greater load. [4] POWER INPUT AC Power M2: 100 – 240 V AC (Operational voltage range 85 – 264 V, 47 – 66 Hz) http://www.m-system.co.jp/ W2RS SPECIFICATIONS ES-5513 Rev.10 Page 1/4 MODEL: W2RS (90 – 264 V for UL) INPUT SPECIFICATIONS DC Power Input: 2- or 3-wire RTD (Refer to 'Cu Input' for the input R: 24 V DC code C.) (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) Maximum leadwire resistance: 200 Ω per wire (3-wire) R2: 11 – 27 V DC Sensing current: 2 mA (Pt);1 mA (Ni 508.4 Ω) (Operational voltage range 11 – 27 V, ripple 10 %p-p max.) (Select ‘/N’ for ‘Standards & Approvals’ code.) OUTPUT SPECIFICATIONS P: 110 V DC ■ DC Current: 0 – 20 mA DC (Operational voltage range 85 – 150 V, ripple 10 %p-p max.) Minimum span: 1 mA (110 V ±10 % for UL) Offset: Max. 1.5 times span Load resistance: Output drive 15 V max. for Output 1; [5] OPTIONS (multiple selections) 7 V max. for Output 2 Response Time (0 – 90 %) ■ DC Voltage: -10 – +12 V DC (up to 10 V for Output 2) blank: Standard (≤ 0.5 sec.) Minimum span: 5 mV /K: Fast Response (Approx. 25 msec.) Offset: Max. 1.5 times span Burnout Load resistance: Output drive 1 mA max.; at ≥ 0.5 V blank: Upscale burnout /BL: Downscale burnout INSTALLATION Standards & Approvlas (must be specified) Power Consumption /N: Without CE or UL •AC Power input: /CE: CE marking Approx. 4 VA at 100 V /UL: UL approval, CE marking Approx. 5 VA at 200 V Other Options Approx. 6 VA at 240 V blank: none •DC power input: Approx. 3 W /Q: Option other than the above (specify the specification) Operating temperature: -5 to +55°C (23 to 131°F) (UL not available) Operating humidity: 30 to 90 %RH (non-condensing) Mounting: Surface or DIN rail SPECIFICATIONS OF OPTION: Q (multiple selections) Weight: 200 g (0.44 lbs) COATING (For the detail, refer to M-System's web site.) /C01: Silicone coating PERFORMANCE in percentage of span /C02: Polyurethane coating Accuracy: ±0.2 % /C03: Rubber coating Refer to ‘Cu INPUT’ for the input code C. ADJUSTMENT Temp. coefficient: ±0.015 %/°C (±0.008 %/°F) /V01: Multi-turn fine adjustment Refer to ‘Cu Input’ for the input code C. TERMINAL SCREW MATERIAL Burnout response: ≤ 10 sec. /S01: Stainless steel Line voltage effect: ±0.1 % over voltage range Insulation resistance: ≥ 100 MΩ with 500 V DC GENERAL SPECIFICATIONS Dielectric strength: 2000 V AC @1 minute (input to output Construction: Plug-in 1 to output 2 to power to ground) Connection: M3 screw terminals (torque 0.8 N·m) Housing material: Flame-resistant resin (black) Cu INPUT Isolation: Input to output 1 to output 2 to power ■ INPUT Overrange output: Approx. -10 to +120 % at 1 – 5 V • Sensing current (resistance span): Zero adjustment: -5 to +5 % (front) 140 Ω ≤ Span ≤ 300 Ω : 1 mA Span adjustment: 95 to 105 % (front) 12 Ω ≤ Span < 140 Ω : 2 mA Burnout: Upscale standard;downscale optional 8 Ω ≤ Span < 12 Ω : 3 mA Linearization: Standard (not available for the input code C) 3.5 Ω ≤ Span < 8 Ω : 5 mA • Max. leadwire resistance: 200 Ω or the value calculated using the equation below, whichever is smaller. http://www.m-system.co.jp/ W2RS SPECIFICATIONS ES-5513 Rev.10 Page 2/4 MODEL: W2RS Leadwire resistance(Ω) = (2500 - 100% resistance(Ω) × Sensing current(mA)) ÷ (3 × Sensing current(mA)) • Usable range: 3.5 Ω ≤ Resistance span(Ω) ≤ 300Ω 100 % resistance(Ω) < (2500 – 3 × Leadwire resistance (Ω) × Sensing current (mA)) ÷ Sensing current (mA) ■ PERFORMANCE • Accuracy Resistance span ≥ 20 Ω: ±0.2 % Otherwise use the equation below: Accuracy(%) = 0.02(Ω) ÷ Resistance span(Ω) × 100 + 0.1(%) × 40(mV) ÷ (Resistance span(Ω) × Sensing current(mA)) • Temperature coefficient Resistance span(Ω) × Sensing current(mA) ≥ 40(mV): ±0.015 %/°C Otherwise use the equation below: Temperature coefficient(%/°C) = 0.015(%/°C) × 40(mV) ÷ (Resistance span(Ω) × Sensing current(mA)) STANDARDS & APPROVALS CE conformity: EMC Directive (2004/108/EC) EMI EN 61000-6-4: 2007 EMS EN 61000-6-2: 2005 Low Voltage Directive (2006/95/EC) EN 61010-1: 2001 Installation Category II Pollution Degree 2 Input or output 1 or output 2 to power input: Reinforced insulation (300 V) Input to output 1 to output 2: Basic insulation (300 V) Approval: UL/C-UL nonincendive Class I, Division 2, Groups A, B, C, and D hazardous locations (UL 1604:2004, CAN/CSA-C22.2 No.213:1987) UL/C-UL general safety requirements (UL 61010B-1:2003, CAN/CSA-C22.2 No.61010-1:1992) http://www.m-system.co.jp/ W2RS SPECIFICATIONS ES-5513 Rev.10 Page 3/4 MODEL: W2RS DIMENSIONS unit: mm (inch) 6 (.23) DIN RAIL 3 2 1 35mm wide 6 5 4 2–4.2x5 (.17x.20) MTG HOLE 6 (.24) deep 9 8 7 11–M3 SCREW 11 10 22 (.87) 29.5 (1.16) 23 (.91) 10 (.39) 84 (3.31) 114 (4.49) [4 (.16)] When mounting, no extra space is needed between units. SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM Burnout RTD A 1 Z S Isolation Reference + Resistor Differential Output B 2 – 7 + Amplifier Driver Constant OUTPUT 1 Current B 4 – 8 Constant Z S Current 5 Linearizer Output + 3 Driver 9 OUTPUT 2 – 6 10 U(+) POWER 11 V(–) Base Socket Remark: The section enclosed by broken line is only with 2nd output option. Specifications are subject to change without notice. http://www.m-system.co.jp/ W2RS SPECIFICATIONS ES-5513 Rev.10 Page 4/4 89 (3.50) 53 (2.09) 59 (2.32) 72 (2.83) 4 (.16)
Frequently asked questions
What makes Elite.Parts unique?

What kind of warranty will the W2RS have?

Which carriers does Elite.Parts work with?

Will Elite.Parts sell to me even though I live outside the USA?

I have a preferred payment method. Will Elite.Parts accept it?

Why buy from GID?

Quality
We are industry veterans who take pride in our work

Protection
Avoid the dangers of risky trading in the gray market

Access
Our network of suppliers is ready and at your disposal

Savings
Maintain legacy systems to prevent costly downtime

Speed
Time is of the essence, and we are respectful of yours
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods