M-SYSTEMS W2DYS
Specifications
Accuracy
±0.1 %
Connection
M3 screw terminals (torque 0.8 N•m)
Construction
Plug-in
Dielectric strength
2000 V AC @1 minute (input to output 1 to output 2 to power to ground)
Housing material
Flame-resistant resin (black)
Insulation resistance
Greater than 100 M Omega with 500 V DC
Isolation
Input to output 1 to output 2 to power
Mounting
Surface or DIN rail
Operating humidity
30 to 90 %RH (non-condensing)
Operating temperature
-5 to +55°C (23 to 131°F)
Output signal
±0.1 % over voltage range
Overrange output
Approx. -10 to +120 % at 1 – 5 V
Power Consumption AC
Approx. 5 VA at 100 V; Approx. 6 VA at 200 V; Approx. 7 VA at 264 V
Power Consumption DC
Approx. 3 W
Response time
= 0.5 sec. (0 – 90 %)
Span adjustment
95 to 105 % (front)
Supply output
±3 % over voltage range
Temp. coefficient
±0.015 %/°C (±0.008 %/°F)
Weight
200 g (0.44 lbs)
Zero adjustment
-5 to +5 % (front)
Features
- 2000V AC isolation
- Applicable to smart transmitters
- Base socket included with modules
- CE marking and UL/C-UL Class 1 Div 2 approval
- Fixed range or PC programmable models selectable
- Powers a 4 – 20 mA DC current loop
- Selectable 100-240V AC/24V DC power input
- Short circuit protection
- Standard DIN rail or surface mounting
- W2 use a compact-size, plug-in socket base for quick installation or replacement of modules without disturbing wiring.
Datasheet
Extracted Text
Model ZERO SPAN ZERO SPAN MODEL: W2DYS B: 2 – 10 mA DC (Load resistance 1500 Ω max.) Space-saving Dual Output Signal Conditioners C: 1 – 5 mA DC (Load resistance 3000 Ω max.) Mini-MW Series D: 0 – 20 mA DC (Load resistance 750 Ω max.) E: 0 – 16 mA DC (Load resistance 900 Ω max.) CURRENT LOOP SUPPLY F: 0 – 10 mA DC (Load resistance 1500 Ω max.) Functions & Features G: 0 – 1 mA DC (Load resistance 15 kΩ max.) • Powers a 4 – 20 mA DC current loop Z: Specify current (See OUTPUT SPECIFICATIONS) • Short circuit protection Voltage • Applicable to smart transmitters 1: 0 – 10 mV DC (Load resistance 10 kΩ min.) • CE marking 2: 0 – 100 mV DC (Load resistance 100 kΩ min.) • UL approval 3: 0 – 1 V DC (Load resistance 1000 Ω min.) 4: 0 – 10 V DC (Load resistance 10 kΩ min.) Typical Applications 5: 0 – 5 V DC (Load resistance 5000 Ω min.) • Various 2-wire transmitters 6: 1 – 5 V DC (Load resistance 5000 Ω min.) • Isolation application (4 – 20 mA input) 0: Specify voltage (See OUTPUT SPECIFICATIONS) 29.5 (1.16) [2] OUTPUT 2 Y: None Current 89 A: 4 – 20 mA DC (Load resistance 350 Ω max.) (3.51) B: 2 – 10 mA DC (Load resistance 700 Ω max.) C: 1 – 5 mA DC (Load resistance 1400 Ω max.) D: 0 – 20 mA DC (Load resistance 350 Ω max.) 124 (4.88) E: 0 – 16 mA DC(Load resistance 430 Ω max.) mm (inch) F: 0 – 10 mA DC (Load resistance 700 Ω max.) G: 0 – 1 mA DC (Load resistance 7000 Ω max.) Z: Specify current (See OUTPUT SPECIFICATIONS) MODEL: W2DYS–24[1][2]-[3][4] Voltage Same range availability as Output 1 ORDERING INFORMATION • Code number: W2DYS-24[1][2]-[3][4] [3] POWER INPUT Specify a code from below for each [1] through [4]. AC Power (e.g. W2DYS-24A6-M2/CE/Q) M: 85 – 264 V AC (Operational voltage range 85 – 264 V, • Special output ranges (For codes Z & 0) 47 – 66 Hz) • Specify the specification for option code ‘Q.’ (e.g. /C01 (Select ‘/N’ for ‘Standards & Approvals’ code.) /S01) M2: 100 – 240 V AC (Operational voltage range 85 – 264 V, Note: If one of the outputs should be a current range, 47 – 66 Hz) specify it for the Output 1 to allow a greater load. (90 – 264 V for UL) DC Power R: 24 V DC SUPPLY OUTPUT (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) 24: 24 V DC R2: 11 – 27 V DC (Operational voltage range 11 – 27 V, ripple 10 %p-p max.) (Select ‘/N’ for ‘Standards & Approvals’ code.) INPUT P: 110 V DC Current (Operational voltage range 85 – 150 V, ripple 10 %p-p max.) 4 – 20 mA DC (110 V ±10 % for UL) [1] OUTPUT 1 [4] OPTIONS (multiple selections) Current Standards & Approvlas (must be specified) A: 4 – 20 mA DC (Load resistance 750 Ω max.) /N: Without CE or UL http://www.m-system.co.jp/ W2DYS SPECIFICATIONS ES-5525 Rev.5 Page 1/3 MODEL: W2DYS /CE: CE marking INSTALLATION /UL: UL approval, CE marking Power Consumption Other Options •AC: blank: none Approx. 5 VA at 100 V /Q: Option other than the above (specify the specification) Approx. 6 VA at 200 V (UL not available) Approx. 7 VA at 264 V •DC: Approx. 3 W Operating temperature: -5 to +55°C (23 to 131°F) SPECIFICATIONS OF OPTION: Q (multiple selections) Operating humidity: 30 to 90 %RH (non-condensing) COATING (For the detail, refer to M-System's web site.) Mounting: Surface or DIN rail /C01: Silicone coating Weight: 200 g (0.44 lbs) /C02: Polyurethane coating /C03: Rubber coating TERMINAL SCREW MATERIAL PERFORMANCE in percentage of span /S01: Stainless steel Accuracy: ±0.1 % Temp. coefficient: ±0.015 %/°C (±0.008 %/°F) Response time: ≤ 0.5 sec. (0 – 90 %) GENERAL SPECIFICATIONS Line voltage effect Construction: Plug-in Supply output: ±3 % over voltage range Connection: M3 screw terminals (torque 0.8 N·m) Output signal: ±0.1 % over voltage range Housing material: Flame-resistant resin (black) Insulation resistance: ≥ 100 MΩ with 500 V DC Isolation: Input to output 1 to output 2 to power Dielectric strength: 2000 V AC @1 minute (input to output Overrange output: Approx. -10 to +120 % at 1 – 5 V 1 to output 2 to power to ground) Zero adjustment: -5 to +5 % (front) Span adjustment: 95 to 105 % (front) STANDARDS & APPROVALS CE conformity: SUPPLY OUTPUT EMC Directive (2004/108/EC) (across the terminals 1 – 5) EMI EN 61000-6-4: 2007 Output voltage: 24 – 28 V DC with no load EMS EN 61000-6-2: 2005 18 V DC min. at 20 mA Low Voltage Directive (2006/95/EC) Current rating: ≤ 22 mA DC EN 61010-1: 2001 • Shortcircuit Protection Installation Category II Current limited: 30 mA max. Pollution Degree 2 Protected time duration: No limit Input or output 1 or output 2 to power input: Reinforced insulation (300 V) INPUT SPECIFICATIONS Input to output 1 to output 2: Basic insulation (300 V) ■ DC Current: Input resistors incorporated Approval: Approx. 300 Ω (50 Ω as receiving resistor, 250 Ω across the UL/C-UL nonincendive Class I, Division 2, monitor terminals) Groups A, B, C, and D hazardous locations (ANSI/ISA-12.12.01:2007, CAN/CSA-C22.2 No.213:1987) UL/C-UL general safety requirements OUTPUT SPECIFICATIONS (UL 61010B-1:2003, CAN/CSA-C22.2 No.1010-1:1992) ■ DC Current: 0 – 20 mA DC Minimum span: 1 mA Offset: Max. 1.5 times span Load resistance: Output drive 15 V max. for Output 1; 7 V max. for Output 2 ■ DC Voltage: 0 – 12 V DC (up to 10 V for Output 2) Minimum span: 5 mV Offset: ≤ 1.5 times span Load resistance: Output drive 1 mA max.; at ≥0.5 V http://www.m-system.co.jp/ W2DYS SPECIFICATIONS ES-5525 Rev.5 Page 2/3 MODEL: W2DYS DIMENSIONS unit: mm (inch) 6 (.23) DIN RAIL 3 2 1 35mm wide 6 5 4 2–4.2x5 (.17x.20) MTG HOLE 6 (.24) deep 9 8 7 11–M3 SCREW 11 10 22 (.87) 29.5 (1.16) 23 (.91) 10 (.39) 84 (3.31) 114 (4.49) [4 (.16)] When mounting, no extra space is needed between units. SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM Z S Isolation Low Drift Output + 1 7 + Amplifier Driver 50Ω INPUT OUTPUT 1 – 2 8 – 2-WIRE XMTR Z S PWR SUPPLY + 5 Output 250Ω + – 3 Current Driver MONITOR V 4 OUTPUT 2 Limiter + 1 – 5V DC – 6 U(+) 10 POWER V(–) 11 Base Socket Remark: The section enclosed by broken line is only with 2nd output option. � When Used as DC Supply � When Used as Isolator 2-WIRE TRANSMITTER – + + 1 + 1 50Ω 50Ω INPUT – 2 – 2 + + 5 5 250Ω 250Ω 4 4 Specifications are subject to change without notice. http://www.m-system.co.jp/ W2DYS SPECIFICATIONS ES-5525 Rev.5 Page 3/3 89 (3.50) 53 (2.09) 59 (2.32) 72 (2.83) 4 (.16)
Frequently asked questions
What makes Elite.Parts unique?

What kind of warranty will the W2DYS have?

Which carriers does Elite.Parts work with?

Will Elite.Parts sell to me even though I live outside the USA?

I have a preferred payment method. Will Elite.Parts accept it?

Why buy from GID?

Quality
We are industry veterans who take pride in our work

Protection
Avoid the dangers of risky trading in the gray market

Access
Our network of suppliers is ready and at your disposal

Savings
Maintain legacy systems to prevent costly downtime

Speed
Time is of the essence, and we are respectful of yours
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods