Specifications
Accuracy
±0.3 %
Average sensing
Sine wave
Connection
M3 screw terminals (torque 0.8 N•m)
Construction
Plug-in
Dielectric strength
2000 V AC @1 minute (input to output 1 to output 2 to power to ground)
Housing material
Flame-resistant resin (black)
Insulation resistance
Greater than 100 M Omega with 500 V DC
Isolation
Input to output 1 to output 2 to power
Line voltage effect
±0.1 % over voltage range
Mounting
Surface or DIN rail
Operating humidity
30 to 90 %RH (non-condensing)
Operating temperature
-5 to +55°C (23 to 131°F)
Over-range output
0 to 120% at 1–5 V
Power Consumption AC
Approx. 4 VA at 100 V; Approx. 5 VA at 200 V; Approx. 6 VA at 240 V
Power Consumption DC
Approx. 3 W
Response time
Less than 0.5 sec. (0 – 90 %)
Ripple
0.5 %p-p max. (100/120 Hz)
Span adjustment
95 to 105% (front)
Temp. coefficient
±0.015 %/°C (±0.008 %/°F)
Weight
200 g (0.44 lbs)
Zero adjustment
-5 to +5% (front)
Features
- 2000V AC isolation
- Base socket included with modules
- CE marking and UL/C-UL Class 1 Div 2 approval
- Converts alternating current from a current transformer into a standard process signal
- CT Protector provided for open-circuit protection
- Fixed range or PC programmable models selectable
- Minimum ripple
- Rerouted input signal does not pass through the base socket in order to protect it from melting caused by rush current of a motor
- Selectable 100-240V AC/24V DC power input
- Standard DIN rail or surface mounting
- W2 use a compact-size, plug-in socket base for quick installation or replacement of modules without disturbing wiring.
Datasheet
Extracted Text
Model ZERO SPAN ZERO SPAN MODEL: W2CA Space-saving Dual Output Signal Conditioners [2] OUTPUT 1 Current Mini-MW Series A: 4 – 20 mA DC (Load resistance 750 Ω max.) B: 2 – 10 mA DC (Load resistance 1500 Ω max.) CT TRANSMITTER C: 1 – 5 mA DC (Load resistance 3000 Ω max.) (Average sensing, RMS calibrated) D: 0 – 20 mA DC (Load resistance 750 Ω max.) Functions & Features E: 0 – 16 mA DC (Load resistance 900 Ω max.) • Converts alternating current from a current transformer F: 0 – 10 mA DC (Load resistance 1500 Ω max.) into a standard process signal G: 0 – 1 mA DC (Load resistance 15 kΩ max.) • Minimum ripple Z: Specify current (See OUTPUT SPECIFICATIONS) • Rerouted input signal does not pass through the base Voltage socket in order to protect it from melting caused by rush 1: 0 – 10 mV DC (Load resistance 10 kΩ min.) current of a motor 2: 0 – 100 mV DC (Load resistance 100 kΩ min.) • CT Protector provided for open-circuit protection 3: 0 – 1 V DC (Load resistance 1000 Ω min.) • CE marking 4: 0 – 10 V DC (Load resistance 10 kΩ min.) • UL approval 5: 0 – 5 V DC (Load resistance 5000 Ω min.) 6: 1 – 5 V DC (Load resistance 5000 Ω min.) Typical Applications 4W: -10 – +10 V DC (Load resistance 10 kΩ min.) • Centralized monitoring and control of motors, pumps or 5W: -5 – +5 V DC (Load resistance 5000 Ω min.) heaters by DCS 0: Specify voltage (See OUTPUT SPECIFICATIONS) • Monitoring power line and power supply current [3] OUTPUT 2 29.5 (1.16) Y: None Current A: 4 – 20 mA DC (Load resistance 350 Ω max.) B: 2 – 10 mA DC (Load resistance 700 Ω max.) 89 C: 1 – 5 mA DC (Load resistance 1400 Ω max.) (3.51) D: 0 – 20 mA DC (Load resistance 350 Ω max.) E: 0 – 16 mA DC(Load resistance 430 Ω max.) F: 0 – 10 mA DC (Load resistance 700 Ω max.) 124 (4.88) G: 0 – 1 mA DC (Load resistance 7000 Ω max.) mm (inch) Z: Specify current (See OUTPUT SPECIFICATIONS) Voltage Same range availability as Output 1 MODEL: W2CA–[1][2][3]-[4][5] [4] POWER INPUT ORDERING INFORMATION AC Power • Code number: W2CA-[1][2][3]-[4][5] M2: 100 – 240 V AC (Operational voltage range 85 – 264 V, Specify a code from below for each [1] through [5]. 47 – 66 Hz) (e.g. W2CA-5AA-M2/CE/Q) (90 – 264 V for UL) • Special output ranges (For codes Z & 0) DC Power • Specify the specification for option code ‘Q.’ R: 24 V DC (e.g. /C01/S01) (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) Note: If one of the outputs should be a current range, R2: 11 – 27 V DC specify it for the Output 1 to allow a greater load. (Operational voltage range 11 – 27 V, ripple 10 %p-p max.) (Select ‘/N’ for ‘Standards & Approvals’ code.) [1] INPUT (sine wave) P: 110 V DC Current (Operational voltage range 85 – 150 V, ripple 10 %p-p max.) 1: 0 – 1 A AC (110 V ±10 % for UL) 5: 0 – 5 A AC http://www.m-system.co.jp/ W2CA SPECIFICATIONS ES-5537 Rev.7 Page 1/3 MODEL: W2CA [5] OPTIONS (multiple selections) INSTALLATION Standards & Approvlas (must be specified) Power Consumption /N: Without CE or UL •AC: /CE: CE marking Approx. 4 VA at 100 V /UL: UL approval, CE marking Approx. 5 VA at 200 V Other Options Approx. 6 VA at 240 V blank: none •DC: Approx. 3 W /Q: Option other than the above (specify the specification) Operating temperature: -5 to +55°C (23 to 131°F) (UL not available) Operating humidity: 30 to 90 %RH (non-condensing) Mounting: Surface or DIN rail Weight: 200 g (0.44 lbs) SPECIFICATIONS OF OPTION: Q (multiple selections) COATING (For the detail, refer to M-System's web site.) /C01: Silicone coating PERFORMANCE in percentage of span /C02: Polyurethane coating Accuracy: ±0.3 % /C03: Rubber coating Temp. coefficient: ±0.015 %/°C (±0.008 %/°F) TERMINAL SCREW MATERIAL Response time: ≤ 0.5 sec. (0 – 90 %) /S01: Stainless steel Ripple: 0.5 %p-p max. (100/120 Hz) Line voltage effect: ±0.1 % over voltage range Insulation resistance: ≥ 100 MΩ with 500 V DC GENERAL SPECIFICATIONS Dielectric strength: 2000 V AC @1 minute (input to output Construction: Plug-in 1 to output 2 to power to ground) Connection: M3 screw terminals (torque 0.8 N·m) Housing material: Flame-resistant resin (black) Isolation: Input to output 1 to output 2 to power STANDARDS & APPROVALS Input waveform CE conformity: Average sensing: Sine wave EMC Directive (2004/108/EC) Overrange output: 0 to 120 % at 1 – 5 V EMI EN 61000-6-4: 2007 Zero adjustment: -5 to +5 % (front) EMS EN 61000-6-2: 2005 Span adjustment: 95 to 105 % (front) Low Voltage Directive (2006/95/EC) EN 61010-1: 2001 Installation Category II INPUT SPECIFICATIONS Pollution Degree 2 Frequency: 50 or 60 Hz Input or output 1 or output 2 to power input: Input burden: Reinforced insulation (300 V) ≤ 0.1 VA (input 0 – 1 A) Input to output 1 to output 2: Basic insulation (300 V) ≤ 0.5 VA (input 0 – 5 A) Approval: Overload capacity: 500 % of rating for 5 sec., 120 % UL/C-UL nonincendive Class I, Division 2, continuous Groups A, B, C, and D hazardous locations Operational range: 0 – 120 % of rating (UL 1604:2004, CAN/CSA-C22.2 No.213:1987) UL/C-UL general safety requirements OUTPUT SPECIFICATIONS (UL 61010B-1:2003, CAN/CSA-C22.2 No.61010-1:1992) ■ DC Current: 0 – 20 mA DC Minimum span: 1 mA Offset: Max. 1.5 times span Load resistance: Output drive 15 V max. for Output 1; 7 V max. for Output 2 ■ DC Voltage: -10 – +12 V DC (up to 10 V for Output 2) Minimum span: 5 mV Offset: Max. 1.5 times span Load resistance: Output drive 1 mA max.; at ≥ 0.5 V http://www.m-system.co.jp/ W2CA SPECIFICATIONS ES-5537 Rev.7 Page 2/3 MODEL: W2CA EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch) CT PROTECTOR (model: CTM2) 6 (.23) approx. 200 (7.9) (total of both sides) DIN RAIL 3 2 1 35mm wide 6 5 4 2–4.2x5 (.17x.20) MTG HOLE 6 (.24) deep 9 8 7 11–M3 SCREW 11 10 22 (.87) 29.5 (1.16) 23 (.91) 10 (.39) 84 (3.31) 114 (4.49) [4 (.16)] • When mounting, no extra space is needed between units. SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM SOURCE Z S INPUT K k TRANSFORMER RMS / Ave. Output + 1 7 Operation Driver CT OUTPUT 1 – 2 8 l L Z S Isolation 4 Output LOAD 3 + Driver 5 OUTPUT 2 6 – 9 10 U(+) POWER CT PROTECTOR 11 V(–) model: CTM2 Base Socket Remark: The section enclosed by broken line is only with 2nd output option. Specifications are subject to change without notice. http://www.m-system.co.jp/ W2CA SPECIFICATIONS ES-5537 Rev.7 Page 3/3 89 (3.50) 53 (2.09) 59 (2.32) 72 (2.83) 28 (1.10)
Frequently asked questions
What makes Elite.Parts unique?

What kind of warranty will the W2CA have?

Which carriers does Elite.Parts work with?

Will Elite.Parts sell to me even though I live outside the USA?

I have a preferred payment method. Will Elite.Parts accept it?

Why buy from GID?

Quality
We are industry veterans who take pride in our work

Protection
Avoid the dangers of risky trading in the gray market

Access
Our network of suppliers is ready and at your disposal

Savings
Maintain legacy systems to prevent costly downtime

Speed
Time is of the essence, and we are respectful of yours
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods