M-SYSTEMS W2AP
Specifications
Accuracy
±0.1 %
Connection
M3 screw terminals (torque 0.8 N•m)
Construction
Plug-in
DC
Approx. 3 W
Dielectric strength
2000 V AC @1 minute (input to output 1 to output 2 to power to ground)
Housing material
Flame-resistant resin (black)
Insulation resistance
Greater than 100 M OMega with 500 V DC
Isolation
Input to output 1 to output 2 to power
Line voltage effect
±0.1 % over voltage range
Mounting
Surface or DIN rail
Operating humidity
30 to 90 %RH (non-condensing)
Operating temperature
-5 to +55°C (23 to 131°F)
Power Consumption AC
Approx. 4 VA at 100 V; Approx. 5 VA at 200 V; Approx. 6 VA at 240 V
Response time
Approx. 3 sec. (0 – 90 %)
Span adjustment
95 to 105 % (front)
Temp. coefficient
±0.015 %/°C (±0.008 %/°F)
Weight
200 g (0.44 lbs)
Zero adjustment
0 – 5 % (front)
Features
- 2000V AC isolation
- Base socket included with modules
- CE marking and UL/C-UL Class 1 Div 2 approval
- Fixed range or PC programmable models selectable
- Provides a pulse rate output in proportion to DC input signal
- Selectable 100-240V AC/24V DC power input
- Standard DIN rail or surface mounting
- W2 use a compact-size, plug-in socket base for quick installation or replacement of modules without disturbing wiring.
Datasheet
Extracted Text
Model ZERO SPAN MODEL: W2AP ( 0 % input must be 0 V.) Space-saving Dual Output Signal Conditioners Mini-MW Series [2] OUTPUT 1 1: Open collector (max. frequency 10 kHz) DC/FREQUENCY CONVERTER (When the dry contact AC/DC switch is selected as Functions & Features one of the outputs, the frequency of the other output • Provides a pulse rate output in proportion to DC input is limited to max. 30 Hz.) signal 2: 5 V pulse (max. frequency 10 kHz) • CE marking (When the dry contact AC/DC switch is selected as • UL approval one of the outputs, the frequency of the other output is limited to max. 30 Hz.) Typical Applications 3: Dry contact AC/DC switch (max. frequency 30 Hz) • Totalizing applications in combination with a counter 29.5 (1.16) [3] OUTPUT 2 Same range availability as Output 1 Y: None 89 (3.51) [4] POWER INPUT AC Power M2: 100 – 240 V AC (Operational voltage range 85 – 264 V, 124 47 – 66 Hz) (4.88) mm (inch) (90 – 264 V for UL) DC Power R: 24 V DC MODEL: W2AP–[1][2][3]-[4][5] (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) R2: 11 – 27 V DC (Operational voltage range 11 – 27 V, ripple 10 %p-p max.) ORDERING INFORMATION (Select ‘/N’ for ‘Standards & Approvals’ code.) • Code number: W2AP-[1][2][3]-[4][5] P: 110 V DC Specify a code from below for each [1] through [5]. (Operational voltage range 85 – 150 V, ripple 10 %p-p max.) (e.g. W2AP-612-M2/CE/Q) (Select ‘/N’ for ‘Standards & Approvals’ code.) • Special input ranges (For codes Z & 0) • Output frequency range (e.g. 0 – 500 Hz) Frequencies of Output 1 and 2 are the same. [5] OPTIONS (multiple selections) • Specify the specification for option code ‘Q.’ Standards & Approvlas (must be specified) (e.g. /C01/S01) /N: Without CE or UL /CE: CE marking /UL: UL approval, CE marking [1] INPUT Other Options Current blank: none A: 4 – 20 mA DC (Input resistance 250 Ω) /Q: Option other than the above (specify the specification) D: 0 – 20 mA DC (Input resistance 50 Ω) (UL not available) G: 0 – 1 mA DC (Input resistance 1000 Ω) H: 10 – 50 mA DC (Input resistance 100 Ω) Z: Specify current (See INPUT SPECIFICATIONS) SPECIFICATIONS OF OPTION: Q (multiple selections) ( 0 % input must be 0 mA.) COATING (For the detail, refer to M-System's web site.) Voltage /C01: Silicone coating 3: 0 – 1 V DC (Input resistance 1 MΩ min.) /C02: Polyurethane coating 4: 0 – 10 V DC (Input resistance 1 MΩ min.) /C03: Rubber coating 5: 0 – 5 V DC (Input resistance 1 MΩ min.) TERMINAL SCREW MATERIAL 6: 1 – 5 V DC (Input resistance 1 MΩ min.) /S01: Stainless steel 0: Specify voltage (See INPUT SPECIFICATIONS) http://www.m-system.co.jp/ W2AP SPECIFICATIONS ES-5535 Rev.6 Page 1/4 MODEL: W2AP GENERAL SPECIFICATIONS OUTPUT PULSE WIDTH Construction: Plug-in � Frequency less than 500 Hz at 100% input Connection: M3 screw terminals (torque 0.8 N·m) � See the figure below. Housing material: Flame-resistant resin (black) • Open Collector • Voltage Pulse Isolation: Input to output 1 to output 2 to power OFF H Level Zero adjustment: 0 – 5 % (front) ON L Level Span adjustment: 95 to 105 % (front) 20% 80% 20% 80% 1 / f 1 / f INPUT SPECIFICATIONS � Frequency greater than 500 Hz at 100% input ■ DC Current: � See the figure and equation below. Shunt resistor attached to the input terminals (0.5 W) • Open Collector • Voltage Pulse Specify input resistance value for code Z. OFF H Level ■ DC Voltage: 0 – 300V DC ON L Level Minimum span: 1V Input resistance: 1 MΩ min. Pulse Width Pulse Width 1 OUTPUT SPECIFICATIONS Pulse Width [millisec.] = 2.09 × 100% Frequency [kHz] • Open Collector: 30 V DC @100 mA (resistive load) Frequency range: 0 – 10 pulses/hour through 10 kHz � When the dry contact AD/DC switch is selected Saturation voltage: 0.6 V DC as one of the outputs: � See the figure below. ON or L pulse width ■ 5 V Pulse is limited within 75 ±25 ms when the output Frequency range: 0 – 10 pulses/hour through 10 kHz frequency is low. Hi level: 3.0 – 5.5 V • Open Collector • Voltage Pulse Lo level: ≤ 0.5 V Dry Contact AC/DC Switch Load resistance: 250 Ω min. OFF H Level ■ Dry Contact AC/DC Switch ON L Level Frequency range: 0 – 10 pulses/hour through 30 Hz 20% 80% 20% 80% Timer: Limits ON time ≤75 ±25 millisec. 1 / f 1 / f Rated load: 132 V AC @200 mA (cos ø = 1) 30 V DC @200 mA (resistive load) Saturation voltage: 3 V DC INSTALLATION Power Consumption •AC: Approx. 4 VA at 100 V Approx. 5 VA at 200 V Approx. 6 VA at 240 V •DC: Approx. 3 W Operating temperature: -5 to +55°C (23 to 131°F) Operating humidity: 30 to 90 %RH (non-condensing) Mounting: Surface or DIN rail Weight: 200 g (0.44 lbs) PERFORMANCE in percentage of span Accuracy: ±0.1 % Temp. coefficient: ±0.015 %/°C (±0.008 %/°F) Response time: Approx. 3 sec. (0 – 90 %) Line voltage effect: ±0.1 % over voltage range Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 2000 V AC @1 minute (input to output 1 to output 2 to power to ground) http://www.m-system.co.jp/ W2AP SPECIFICATIONS ES-5535 Rev.6 Page 2/4 MODEL: W2AP STANDARDS & APPROVALS CE conformity: EMC Directive (2004/108/EC) EMI EN 61000-6-4: 2007 EMS EN 61000-6-2: 2005 Low Voltage Directive (2006/95/EC) EN 61010-1: 2001 Installation Category II Pollution Degree 2 Input or output 1 or output 2 to power input: Reinforced insulation (300 V) Input to output 1 to output 2: Basic insulation (300 V) Approval: UL/C-UL nonincendive Class I, Division 2, Groups A, B, C, and D hazardous locations (UL 1604:2004, CAN/CSA-C22.2 No.213:1987) UL/C-UL general safety requirements (UL 61010B-1:2003, CAN/CSA-C22.2 No.61010-1:1992) DIMENSIONS unit: mm (inch) 6 (.23) DIN RAIL 3 2 1 35mm wide 6 5 4 2–4.2x5 (.17x.20) MTG HOLE 6 (.24) deep 9 8 7 11–M3 SCREW 11 10 22 (.87) 29.5 (1.16) 23 (.91) 10 (.39) 84 (3.31) 114 (4.49) [4 (.16)] When mounting, no extra space is needed between units. TERMINAL ASSIGNMENTS unit: mm (inch) INPUT RESISTOR (model: REM2) 3 2 1 6 5 4 9 8 7 11 10 Input shunt resistor attached for current input. http://www.m-system.co.jp/ W2AP SPECIFICATIONS ES-5535 Rev.6 Page 3/4 89 (3.50) 53 (2.09) 19 (.75) 59 (2.32) 72 (2.83) 4 (.16) MODEL: W2AP SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM Z S Isolation ** Low Drift Volt. / Freq. Output + Divider Timer + 1 7 * Amplifier Converter Driver INPUT R OUTPUT 1 – – 2 8 4 Output + 3 Driver OUTPUT 2 5 – 6 9 10 U(+) POWER 11 V(–) Base Socket * Input shunt resistor attached for current input. **Provided only when the dry contact AC/DC switch is selected as one of the outputs. Remark: The section enclosed by broken line is only with 2nd output option. Output Connection Examples � Open Collector � Dry Contact AC/DC Switch • AC Powered Relay or Counter Coil 7 + + 7 Varistor or Spark Quenching Circuit 8 – – 8 LOAD � Voltage Pulse • DC Powered Relay or Counter Coil + + 7 7 Spark Quenching Diode – – LOAD 8 8 Specifications are subject to change without notice. http://www.m-system.co.jp/ W2AP SPECIFICATIONS ES-5535 Rev.6 Page 4/4
Frequently asked questions
What makes Elite.Parts unique?

What kind of warranty will the W2AP have?

Which carriers does Elite.Parts work with?

Will Elite.Parts sell to me even though I live outside the USA?

I have a preferred payment method. Will Elite.Parts accept it?

Why buy from GID?

Quality
We are industry veterans who take pride in our work

Protection
Avoid the dangers of risky trading in the gray market

Access
Our network of suppliers is ready and at your disposal

Savings
Maintain legacy systems to prevent costly downtime

Speed
Time is of the essence, and we are respectful of yours
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods