M-SYSTEMS W2AC
Specifications
AC Power input
Approx. 4 VA at 100 V; Approx. 5 VA at 200 V; Approx. 6 VA at 240 V
Accuracy
±0.4 %
Connection
M3 screw terminals (torque 0.8 N•m)
Construction
Plug-in
DC Power input
Approx. 3 W
Dielectric strength
2000 V AC @1 minute (input to output 1 to output 2 to power to ground)
Housing material
Flame-resistant resin (black)
Insulation resistance
Greaten Than 100 M Omega with 500 V DC
Isolation
Input to output 1 to output 2 to power
Line voltage effect
±0.1 % over voltage range
Mounting
Surface or DIN rail
Operating humidity
30 to 90 %RH (non-condensing)
Operating temperature
-5 to +55°C (23 to 131°F)
Over-range output
0 to 120 % at 1 – 5 V
Response time
Less than 0.7 sec. (0 – 90 %)
Ripple
0.5 %p-p max. (50/60 Hz)
RMS sensing
Up to 15 % of 3rd harmonic content
Span adjustment
95 to 105 % (front)
Temp. coefficient
±0.05 %/°C (±0.03 %/°F)
Weight
Approx. 200 g (0.44 lbs)
Zero adjustment
-5 to +5 % (front)
Features
- 2000V AC isolation
- Base socket included with modules
- CE marking and UL/C-UL Class 1 Div 2 approval
- Converts an alternating current/voltage input into a standard process signal
- Fixed range or PC programmable models selectable
- Selectable 100-240V AC/24V DC power input
- Standard DIN rail or surface mounting
- True RMS sensing
- Two independent output ranges
- W2 use a compact-size, plug-in socket base for quick installation or replacement of modules without disturbing wiring.
Datasheet
Extracted Text
Model ZERO SPAN ZERO SPAN MODEL: W2AC A5: 0 – 10 V AC (Input resistance Approx. 100 kΩ min.) Space-saving Dual Output Signal Conditioners A6: 0 – 120 V AC (Input resistance Approx. 100 kΩ min.) Mini-MW Series A7: 0 – 150 V AC (Input resistance Approx. 100 kΩ min.) A8: Specify voltage (Input resistance Approx. 100 kΩ min.) AC TRANSMITTER ( 0 % input must be 0 V.) Functions & Features • Converts an alternating current/voltage input into a [2] OUTPUT 1 standard process signal Current • True RMS sensing A: 4 – 20 mA DC (Load resistance 750 Ω max.) • Two independent output ranges B: 2 – 10 mA DC (Load resistance 1500 Ω max.) • CE marking C: 1 – 5 mA DC (Load resistance 3000 Ω max.) • UL approval D: 0 – 20 mA DC (Load resistance 750 Ω max.) E: 0 – 16 mA DC (Load resistance 900 Ω max.) Typical Applications F: 0 – 10 mA DC (Load resistance 1500 Ω max.) • Converting high AC current in combination with a shunt G: 0 – 1 mA DC (Load resistance 15 kΩ max.) resistor, or narrow span AC voltage Z: Specify current (See OUTPUT SPECIFICATIONS) Voltage 29.5 (1.16) 1: 0 – 10 mV DC (Load resistance 10 kΩ min.) 2: 0 – 100 mV DC (Load resistance 100 kΩ min.) 3: 0 – 1 V DC (Load resistance 1000 Ω min.) 89 4: 0 – 10 V DC (Load resistance 10 kΩ min.) (3.51) 5: 0 – 5 V DC (Load resistance 5000 Ω min.) 6: 1 – 5 V DC (Load resistance 5000 Ω min.) 4W: -10 – +10 V DC (Load resistance 10 kΩ min.) 124 (4.88) 5W: -5 – +5 V DC (Load resistance 5000 Ω min.) mm (inch) 0: Specify voltage (See OUTPUT SPECIFICATIONS) [3] OUTPUT 2 MODEL: W2AC–[1][2][3]-[4][5] Y: None Current ORDERING INFORMATION A: 4 – 20 mA DC (Load resistance 350 Ω max.) • Code number: W2AC-[1][2][3]-[4][5] B: 2 – 10 mA DC (Load resistance 700 Ω max.) Specify a code from below for each [1] through [5]. C: 1 – 5 mA DC (Load resistance 1400 Ω max.) (e.g. W2AC-A1AA-M2/CE) D: 0 – 20 mA DC (Load resistance 350 Ω max.) • Special output ranges (For codes AZ, A8, Z & 0) E: 0 – 16 mA DC(Load resistance 430 Ω max.) If one of the outputs should be a current range, specify it for F: 0 – 10 mA DC (Load resistance 700 Ω max.) the Output 1 to allow a greater load. G: 0 – 1 mA DC (Load resistance 7000 Ω max.) Z: Specify current (See OUTPUT SPECIFICATIONS) [1] INPUT Voltage Current Same range availability as Output 1 AA: 0 – 10 mA AC (Input resistance 100 Ω) AB: 0 – 50 mA AC (Input resistance 20 Ω) [4] POWER INPUT AC: 0 – 100 mA AC (Input resistance 10 Ω) AC Power AD: 0 – 500 mA AC (Input resistance 1 Ω) M2: 100 – 240 V AC (Operational voltage range 85 – 264 V, AZ: Specify current (See INPUT SPECIFICATIONS) 47 – 66 Hz) ( 0 % input must be 0 mA.) (90 – 264 V for UL) Voltage DC Power A1: 0 – 100 mV AC (Input resistance Approx. 100 kΩ min.) R: 24 V DC A2: 0 – 500 mV AC (Input resistance Approx. 100 kΩ min.) (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) A3: 0 – 1 V AC (Input resistance Approx. 100 kΩ min.) R2: 11 – 27 V DC A4: 0 – 5 V AC (Input resistance Approx. 100 kΩ min.) (Operational voltage range 11 – 27 V, ripple 10 %p-p max.) http://www.m-system.co.jp/ W2AC SPECIFICATIONS ES-5536 Rev.5 Page 1/3 MODEL: W2AC (Select ‘/N’ for ‘Standards & Approvals’ code.) INSTALLATION P: 110 V DC Power Consumption (Operational voltage range 85 – 150 V, ripple 10 %p-p max.) •AC Power input: (110 V ±10 % for UL) Approx. 4 VA at 100 V Approx. 5 VA at 200 V Approx. 6 VA at 240 V [5] OPTIONS •DC Power input: Approx. 3 W STANDARDS & APPROVALS (must be specified) Operating temperature: -5 to +55°C (23 to 131°F) /N: Without CE or UL Operating humidity: 30 to 90 %RH (non-condensing) /CE: CE marking Mounting: Surface or DIN rail /UL: UL approval (CE marking) Weight: Approx. 200 g (0.44 lbs) GENERAL SPECIFICATIONS PERFORMANCE in percentage of span Construction: Plug-in Accuracy: ±0.4 % Connection: M3 screw terminals (torque 0.8 N·m) Temp. coefficient: ±0.05 %/°C (±0.03 %/°F) Housing material: Flame-resistant resin (black) Response time: ≤ 0.7 sec. (0 – 90 %) Isolation: Input to output 1 to output 2 to power Ripple: 0.5 %p-p max. (50/60 Hz) Input waveform Line voltage effect: ±0.1 % over voltage range RMS sensing: Up to 15 % of 3rd harmonic content Insulation resistance: ≥ 100 MΩ with 500 V DC Overrange output: 0 to 120 % at 1 – 5 V Dielectric strength: 2000 V AC @1 minute (input to output Zero adjustment: -5 to +5 % (front) 1 to output 2 to power to ground) Span adjustment: 95 to 105 % (front) STANDARDS & APPROVALS INPUT SPECIFICATIONS CE conformity: Frequency: 40 Hz min., 1 kHz max. with 100% input EMC Directive (2004/108/EC) • AC Current: 0 – 1 A AC; input resistor incorporated EN 61000-6-4 (EMI) Minimum span: 1 mA EN 61000-6-2 (EMS) Input resistance Low Voltage Directive (2006/95/EC) Range 1 mA: 1 kΩ EN 61010-1 Range ≤ 2 mA: 500 Ω Installation Category II Range ≤ 5 mA: 200 Ω Pollution Degree 2 Range ≤ 10 mA: 100 Ω Max. operating voltage 300 V Range ≤ 20 mA: 50 Ω Input or output 1 or output 2 to power: Reinforced Range ≤ 50 mA: 20 Ω insulation Range ≤ 100 mA: 10 Ω Input to output 1 to output 2: Basic insulation Range ≤ 500 mA: 1 Ω Approval: Range ≤ 1 A: 0.5 Ω UL/C-UL nonincendive Class I, Division 2, • AC Voltage: 0 – 250 V AC Groups A, B, C, and D hazardous locations Minimum span: 50 mV (UL 1604, CAN/CSA-C22.2 No.213) Input resistance: Approx. 100 kΩ min. UL/C-UL general safety requirements (UL 61010B-1, CAN/CSA-C22.2 No.1010-1) OUTPUT SPECIFICATIONS • DC Current: 0 – 20 mA DC Minimum span: 1 mA Offset: Max. 1.5 times span Load resistance: Output drive 15 V max. for Output 1; 7 V max. for Output 2 • DC Voltage: -10 – +12 V DC (up to 10 V for Output 2) Minimum span: 5 mV Offset: Max. 1.5 times span Load resistance: Output drive 1 mA max.; at ≥ 0.5 V http://www.m-system.co.jp/ W2AC SPECIFICATIONS ES-5536 Rev.5 Page 2/3 MODEL: W2AC DIMENSIONS unit: mm (inch) 6 (.23) DIN RAIL 3 2 1 35mm wide 6 5 4 2–4.2x5 (.17x.20) MTG HOLE 6 (.24) deep 9 8 7 11–M3 SCREW 11 10 22 (.87) 29.5 (1.16) 23 (.91) 10 (.39) 84 (3.31) 114 (4.49) [4 (.16)] • When mounting, no extra space is needed between units. SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM Z S Isolation AC R.M.S. Output * 1 7 + Amplifier Operation Driver INPUT OUTPUT 1 2 8 – Z S 4 Output + 3 Driver 5 OUTPUT 2 – 6 9 10 U(+) POWER 11 V(–) Base Socket *Input shunt resistor incorporated for current input. Remark: The section enclosed by broken line is only with 2nd output option. Specifications are subject to change without notice. http://www.m-system.co.jp/ W2AC SPECIFICATIONS ES-5536 Rev.5 Page 3/3 89 (3.50) 53 (2.09) 59 (2.32) 72 (2.83)
Frequently asked questions
What makes Elite.Parts unique?

What kind of warranty will the W2AC have?

Which carriers does Elite.Parts work with?

Will Elite.Parts sell to me even though I live outside the USA?

I have a preferred payment method. Will Elite.Parts accept it?

Why buy from GID?

Quality
We are industry veterans who take pride in our work

Protection
Avoid the dangers of risky trading in the gray market

Access
Our network of suppliers is ready and at your disposal

Savings
Maintain legacy systems to prevent costly downtime

Speed
Time is of the essence, and we are respectful of yours
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods