LFE 195
Features
- Long Life Lamp Operation
- On/Off or Alarm Control
- Plastic Front and Base
- Plug-In Control Module
- Proven Optical Setpoints
Datasheet
Extracted Text
LFE Analog Optical Meter Relays Series Analog Optical Meter-Relays 195 Series Optical Meter-Relays • Plug-In Control Module • Long Life Lamp Operation • Plastic Front and Base • Proven Optical Setpoints • On/Off or Alarm Control 196 Series Optical Meter-Relays • Modern Rectangular Appearance • Plug-In Control Module • Proven Optical Setpoints • Limit Lights & Manual Reset Switches Optional (Model 1967) The 195 Series and 196 Series Meter-Relays contain an exclusive light sensitive transistor switch that provides the ultimate in control simplicity and reliability. This switch controls the load relays. There are no pointer contacts or mechanical interference in the meter mechanism. The controllers are supplied with a plug-in control module that mounts directly on the rear of the Meter-Relay or may be remotely mounted with an accessory cable. 196 ▲ OPTICAL METER-RELAYS—195 & 196 SERIES SPECIFICATIONS DIMENSIONS DC Ranges AC Ranges (Rectifier Type) 196 Series Dimensions Current Voltage Current Voltage Model Height Width Depth* Depth w/Module* Accuracy: ±2% ±2% ±3% ±3% 1 1963 (3 2 ⁄ ")3.006 3.756 2.897 6.745 Balance: ±1% ±1% ±1% ±1% 1 1964 (4 2 ⁄ ")3.756 4.632 2.897 6.745 Repeatability: ±2% ±2% ±2% ±2% 195 Series Dimensions Resistance Tolerance: ±20% ±5% — <10V ±20% Model Height Width Depth* Depth ≥10V ±5% w/ Module* Overload 1 Second 1000% ≤100V 1000% 150% 1 1953 (3 2 ⁄ ") 3.50 3.50 2.897 6.745 Capacity >100V 200% 150% 150% 1 1954 (4 2 ⁄ ") 4.41 4.85 2.897 6.745 Continuous 150% 120% 150% 150% Calibration Frequency: N/A N/A 60 Hz 60 Hz Overshoot (maximum): 20% 20% 20% 20% Response Time (maximum): 3 sec 3 sec 3 sec 3 sec OPTIONS (WHERE APPLICABLE) 50 Supply Power: 120 VAC /60 Hz 7 VA MAX Setpoint Stop (Sgl or Dbl) Load Relay Rating: DPDT 5A @ 120 VAC Relative (Model 1967-SPDT only) Screwdriver Adjust Non-listed Ranges Effects of shock, vibration, humidity and temperature are equal to or better than ANSI C39.1- Suppressed Ranges 1981. Safety (dielectric test, leakage and other hazards): instruments are equal to or better than Stabister Protection: ANSI C39.5-1974. DC (Left or right) DC (zero center) The above tolerance limits apply to the standard ranges listed in this bulletin. Special instruments AC may vary from these limits. Rated circuit to ground voltage=800 RMS (1100 Peak). AC or DC Voltmeters w/cal. adjust pot One-time eng. charge for “customer specials” *Depth = Front of Panels to End of Terminals Double High or Double Low or Double Reversed 79a ANALOG METERS LFE Analog Optical Meter Relays DC Ranges AC Ranges ORDERING GUIDE On/Off Control, Single High Setpoint On/Off Control, Single High Setpoint Model Number Part Number Prefix Range Part Number Range Part Number 1953 Change XX to V3 Microamperes Micromperes 1954 Change XX to V4 0-50 XX-10CY-CY00 0-500 XX-14EM-EM00 1963 Change XX to W3 50-0-50 XX-16CY-CY00 0-800 XX-14EW-EW00 1964 Change XX to W4 0-100 XX-10DR-DR00 Milliamperes 0-200 XX-10EA-EA00 0-1 XX-14FA-FA00 0-500 XX-10EM-EM00 Amperes Transformer Rated 195 & 196 SERIES METER RELAY Milliamperes 0-5 XX-14LA-LS00 ACCESSORIES AND OPTIONS 0-1 to 0-800 (See Note) 0-10 XX-14LS-MT00 Accessories/Parts 0-1 XX-10FA-FA00 0-15 XX-14LS-ND00 Description Part Number 0-5 XX-10FX-FX00 0-20 XX-14LS-NG00 Control Module (Factory Style #3) 0-10 XX-10GZ-GZ00 0-25 XX-14LS-NJ00 High Setpoint 8889-0003 0-30 XX-14LS-NL00 0-500 XX-10KM-KM00 Amperes 0-40 XX-14LS-NP00 Low Setpoint 8889-2003 0-1 to 0-50 (See Note) 0-50 XX-14LS-NT00 Double Setpoint 8889-3003 0-5 XX-10LS-LS00 0-75 XX-14LS-PB00 Control Modules (Factory Style #2) 0-20 XX-10NG-NG00 0-100 XX-14LS-PK00 High Setpoint 8889-0001 0-50 XX-10NT-NT00 0-150 XX-14LS-PZ00 Low Setpoint 8889-2001 Millivolts (Shunt Rated) 0-200 XX-14LS-RL00 Double Setpoints 8889-3001 0-50 XX-11EC-EC00 0-250 XX-14LS-RS00 Remote Mounting Kit 0-100 XX-11GB-GB00 0-300 XX-14LS-RX00 Complete Kit 1125-426 Millivolts (For Transducer Applications) 0-400 XX-14LS-SC00 Kit w/o cable 1125-425 0-50 XX-12HY-HY00 0-500 XX-14LS-SF00 New Style Lamp/Holder Assembly 0-100 XX-12JR-JR00 0-600 XX-14LS-SJ00 Volts 1000 Ohms/Volt 0-800 XX-14LS-SN00 1207-246 0-1 to 0-600 (See Note) Volts 1000 Ohms/Volt Current Transformers (20 mA AC Secondary) 0-150 XX-12PZ-PZ00 0-10 to 0-300 (See Note) Primary Rating: 0-300 XX-12RX-RX00 0-150 XX-15PZ-PZ00 5A 2062-0150 0-600 XX-12SJ-SJ00 Note: Order by Description DC Ammeters 50 mV Shunt-Rated DC Ammeters 100 mV Shunt-Rated On/Off Control, Single High Setpoint On/Off Control, Single High Setpoint 195 & 196 OPTIONAL SETPOINTS Scale Part Number Scale Part Number Amperes Amperes Range Part Number 0-1 XX-11EC-LA00 0-1 XX-11GB-LA00 Single Low Setpoint 0-2 XX-11EC-LE00 0-2 XX-11GB-LE00 Same as Single Same as Single High Same as Single 0-3 XX-11EC-LJ00 0-3 XX-11GB-LJ00 High Setpoint Setpoint Models Except High Setpoint 0-5 XX-11EC-LS00 0-5 XX-11GB-LS00 Models Change digit #3 from 1 to 2 Models 0-7.5 XX-11EC-MF00 0-7.5 XX-11GB-MF00 0-10 XX-11EC-MT00 0-10 XX-11GB-MT00 Double Setpoint 0-15 XX-11EC-ND00 0-15 XX-11GB-ND00 Same as Single Same as Single High 0-20 XX-11EC-NG00 0-20 XX-11GB-NG00 High Setpoint Setpoint Models Except Single High 0-30 XX-11EC-NL00 0-30 XX-11GB-NL00 Models Change Digit #3 from 1 to 3 Setpoint 0-40 XX-11EC-NP00 0-40 XX-11GB-NP00 Models 0-50 XX-11EC-NT00 0-50 XX-11GB-NT00 0-60 XX-11EC-NW00 0-60 XX-11GB-NW00 Manual Reset Pushbutton and Alarm Lights 0-75 XX-11EC-PB00 0-75 XX-11GB-PB00 1 4 /2 inch Model Digit 1 & 2 changes Single Setpoint 0-80 XX-11EC-PD00 0-80 XX-11GB-PD00 196 ONLY 1964 from W4 to W7 0-100 XX-11EC-PK00 0-100 XX-11GB-PK00 Changes to 1967 Double Setpoint 0-150 XX-11EC-PZ00 0-150 XX-11GB-PZ00 0-200 XX-11EC-RL00 0-200 XX-11GB-RL00 0-250 XX-11EC-RS00 0-250 XX-11GB-RS00 0-300 XX-11EC-RX00 0-300 XX-11GB-RX00 0-400 XX-11EC-SC00 0-400 XX-11GB-SC00 0-500 XX-11EC-SF00 0-500 XX-11GB-SF00 0-600 XX--11EC-SJ00 0-600 XX-11GB-SJ00 0-800 XX--11EC-SN00 0-800 XX-11GB-SN00 0-1000 XX--11EC-VA00 0-1000 XX-11GB-VA00 0-1200 XX--11EC-VB00 0-1200 XX-11GB-VB00 0-1500 XX--11EC-VC00 0-1500 XX-11GB-VC00 0-2000 XX--11EC-VE00 0-2000 XX-11GB-VE00 79b
Frequently asked questions
What makes Elite.Parts unique?

What kind of warranty will the 195 have?

Which carriers does Elite.Parts work with?

Will Elite.Parts sell to me even though I live outside the USA?

I have a preferred payment method. Will Elite.Parts accept it?

What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods