LEM DHR 100 C420

Description

LEM DHR 100 C420 Transducer - CURRENT TRANSDUCER, 100A 4-20MA O/PCURRENT TRANSDUCER, 100A 4-20MA O/P

Part Number

DHR 100 C420

Price

Request Quote

Manufacturer

LEM

Lead Time

Request Quote

Category

TBD

Specifications

Accuracy, percentage

1%

Basic

CURRENT TRANSDUCER, 100A 4-20MA O/PCURRENT TRANSDUCER, 100A 4-20MA O/P

Current measuring ranges, AC

100 A

Current measuring ranges, DC

100 A

Current, load max

30mA

Current, max

600A

Current, supply

30mA

RoHS Compliant

Yes

Features

Datasheet

pdf file

LEM-DHR 100 C420-datasheet1-2098766788.pdf

717 KiB

Extracted Text

AC/DC Current Transducer DHR-C420 I = 100 .. 1000 A PN The transducer for the electronic measurement of DC & distorted AC waveform currents, with galvanic isolation between the primary circuit (power) and the secondary circuit (measurement). True RMS 4-20 mA current output. Electrical data Primary Nominal Primary AC Current Output current Type 1) DC & AC Current Max. Peak Value Features I (A.t.RMS) I (A) I (mA DC) PN P OUT 100 600 4-20 DHR 100 C420 ● VFD and SCR waveforms current 200 600 4-20 DHR 200 C420 measurement 300 1000 4-20 DHR 300 C420 ● True RMS output 400 1000 4-20 DHR 400 C420 ● 4-20 mA current output 2) 500 1800 4-20 DHR 500 C420 ● Panel mounting 2) 600 1800 4-20 DHR 600 C420 ● Eliminates insertion loss 2) 1000 1800 4-20 DHR 1000 C420 ● Isolated plastic case recognized according to UL94-V0 R Load resistance < 300 W L V Supply voltage + 20 .. 50 V DC C Advantages I Current consumption 30 mA + I C OUT I Output current limitation < 25 mA ● Large aperture for cable up to SL Î Overload capability (Ampere Turns) 30000 A.t Ø32mm P ● High isolation between primary Performance data and secondary circuits ● Easy installation X Accuracy @ I , T = 25°C (excluding offset) < ± 1 % of I PN A PN Applications e Linearity error (1% of I .. ± I ) < ± 1.0 % of I L PN PN PN I Electrical offset current, T = 25°C 4 mA OE A ● VFD Controlled Loads TCI Temperature coefficient of I ( 0..+60 °C) ± 3.2 mA/K OE OE VFD output indicates how the (-40..+70 °C) ± 6.4 mA/K motor and attached load are TCI Temperature coefficient of I (% of reading) ± 0.1 %/K OUT OUT operating. t Response time to 90 % of I step < 150 ms r PN ● SCR Controlled Loads BW Frequency bandwidth (± 1 dB) DC 20..6000 Hz Acurate measurement of phase angle fired or burst fired (time General data proportioned) SCRs. Current measurement gives faster T Surrounding operating temperature - 40 .. + 70 °C A response than temperature T Surrounding storage temperature - 40 .. + 85 °C S measurement. m Mass 260 g ● Switching Power Supplies and IPxx Protection degree IP20 Electronic Ballasts True RMS sensing is the most accurate way to measure power 1) supply or ballast input power. Notes : The Max. Peak AC Current is the highest peak level of the primary signal that is taken into account for accurate True RMS calculation. Yet Application domain the device is designed for maximum continuous True RMS value equal to I , whereas the output is limited by the above specified output limitation. PN ● Energy and Automation 2) According to the UL 508 Standard for Safety for Industrial Control Equipment the primary current must not exceed 475 A.t.RMS through the transducer hole. Page 1/4 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. 100518/20 www.lem.com Current Transducer DHR-C420 Isolation characteristics 3) V Rated isolation voltage rms 300 V b according to the standard IEC 61010-1 and with the following conditions: - Reinforced isolation - Over voltage category CAT III - Pollution degree PD2 - Heterogeneous field 4) V Rms voltage for AC isolation test , 50 Hz, 1min 4.0 kV d V 4) w Impulse withstand voltage , 1.2/50 uS 7.3 kV dCp Creepage distance 7.2 mm dCl Clearance distance 7.2 mm CTI Comparative tracking index (Group I) > 600 3) Notes : Between primary conductor voltage and ground. The voltage category could be improved according to the insulation characteristic given by the cable manufacturer. The UL 508 Standard for Safety for Industrial Control Equipment requires that only insulated conductors are used as primary circuit with this transducer. 4) Between primary (completely filling the aperture) and secondary. Transfer characteristics Output in mA 20 4 -Ipn +Ipn Page 2/4 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. 100518/20 www.lem.com Current Transducer DHR-C420 Safety and warning notes In order to guarantee safe operation of the transducer and to be able to make proper use of all features and functions, please read these instructions thoroughly! Safe operation can only be guaranteed if the transducer is used for the purpose it has been designed for and within the limits of the technical specifications. Ensure you get up-to-date technical information that can be found in the latest associated datasheet under www.lem.com. Caution! Risk of danger Ignoring the warnings can lead to serious injury and/or cause damage! The electric measuring transducer may only be installed and put into operation by qualified personnel that have received an appropriate training. The corresponding national regulations shall be observed during installation and operation of the transducer and any electrical conductor. The transducer shall be used in electric/electronic equipment with respect to applicable standards and safety requirements and in accordance with all the related systems and components manufacturers’ operating instructions. Caution! Risk of electrical shock When operating the transducer, certain parts of the module may carry hazardous live voltage (e.g. primary conductor, power supply). The user shall ensure to take all measures necessary to protect against electrical shock. The transducer is a built-in device containing conducting parts that shall not be accessible after installation. A protective enclosure or additional insulation barrier may be necessary. The transducer shall not be put into operation if the jaw opening is open (split core version) or the installation is not completed. Installation and maintenance shall be done with the main power supply disconnected except if there are no hazardous live parts in or in close proximity to the system and if the applicable national regulations are fully observed. Safe and trouble-free operation of this transducer can only be guaranteed if transport, storage and installation are carried out correctly and operation and maintenance are carried out with care. Page 3/4 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. 100518/20 www.lem.com Dimensions DHR-C420 (in mm. 1 mm = 0.0394 inch)   Dimensions DHR-C420 (in mm. 1 mm = 0.0394 inch)  25 70 60  6.80 22.28      90 4 15 7   • • •• • • • ••••••••••• 6 78 2NWIKPEQPPGEVQT •• •••• •••••••••• (-%564( •• •2 ••J •Q •G •P ••K ••Z • ••% ••QPVCEV DHR-C420 Connections Connections ● Wires up to Ø 2 mm DHR • Wires up to ∅ 2 mm ● Female connector provided (spring terminal blocks) • Female connector provided (spring terminal blocks) ● User-friendly spring-cage connection for no-tool direct • User-friendly spring-cage connection for no-tool conductor connection Output Connector direct conductor connection 1(Vcc) 2(Iout) 3(NC) 4(GND) Mechanical characteristics 24 VDC Power ● General tolerance ±1 mm Mechanical characteristics (+) ● Primary aperture Ø 32.0 mm • General tolerance ±1 mm ● Panel mounting 4 holes Ø 4.6 mm • Primary aperture ∅ 32.0 mm (-) ● Distance between holes 70.0 mm & 78 mm • Panel mounting 4 holes ∅ 4.6 mm (see above dimensions) • Distance between holes 70 mm & 78 mm For panel mounting, use M4 screws (not supplied) with (see above drawings) appropriate length to panel´s thickness, and tighten to (-) (+) For panel mounting, replace M4 screws by new one (not supplied) 0.75Nm +/-20% torque. Load with appropriate length to panel´s thickness. (Controller, meter etc) Remarks ● The temperature of the primary busbar can not exceed Remarks 90 °C. • The temperature of the primary conductor can not exceed 90 °C. + +2 24 4V VD DC C ● Dynamic performances are the best with a primary I Is s O OU UT T • Dynamic performances are the best with a primary conductor busbar completely filling the primary aperture. completely filling the primary aperture. ● This is a standard model. For different versions I Ip p • This is a standard model. For different versions (supply voltages, (supply voltages, different outputs, bidirectional GND GND GND different outputs, bidirectional measurement,...), please measurements...), please contact us. Page 4/4 contact us. LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. 100518/20 www.lem.com Page 4/4 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. 080725/16 www.lem.com  4.60     25  33.80 15 4.60   8.30 32 6.80    10 2.50  40 8.30 70  25.60 

Frequently asked questions

What makes Elite.Parts unique?

chervon down
At GID Industrial (Elite.Parts' parent company), we specialize in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

What kind of warranty will the DHR 100 C420 have?

chervon down
Warranties differ by part and by which suppliers we use to procure it for you. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carriers does Elite.Parts work with?

chervon down
Elite.Parts can ship via FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Will Elite.Parts sell to me even though I live outside the USA?

chervon down
Absolutely! We are happy to serve customers regardless of location. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

I have a preferred payment method. Will Elite.Parts accept it?

chervon down
All major credit cards are accepted: Visa, MasterCard, Discover, and American Express. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

EARTH/GROUND TESTER, UNILAPEARTH/GROUND TESTER, UNILAP Accuracy, percentage:7% Depth, external:9...

GEO MEASURING SET 4 POLE RoHS Compliant: NA

DMM, CLAMP POWER AC/DCDMM, CLAMP POWER AC/DC CalibrationCode:20 Current measuring ranges, AC:40/40...

POWER QUALITY ANALYSER

product

LEM DHR 600 C420 AC/DC Current Transducer DHR-C420 600A @ Primary Nominal DC & AC Current and 1800A ...

product

LEM-HA10NPSP2-Transducer