Lambda MML-600-DD-T2 Power Supplies-POWER SUPPLY OMEGA SERIES VDC/A 24/12.5 24/12.5

Part Number

MML-600-DD-T2

Price

Request Quote

Manufacturer

LAMBDA

Lead Time

Request Quote

Category

PRODUCTS - M

Specifications

AC power fail

Opto isolated input standard on MML600, 800, MML400PFC

Inhibit

Opto isolated input standard on MML600, 800, MML400PFC

Input protection

internal fuse

Input voltage range

85-264VAC

Input/output resistance

30Mohms/ 500VDC

Maximum Power W

600W

Number of Slots

4

Output Amps(1)

25A

Output Volts(1)

24V

Power factor

> 0.9

Switching frequency

100KHz

Thermal protection

standard

Voltage isolation

Input-output 3.0KV RMS;Input-ground 1.5KV RMS;Output-ground 500VDC

Datasheet

pdf file

Lambda-Omega-ds1-685641646.pdf

220 KiB

Extracted Text

Series OMEGA INPUT Input protection internal fuse Thermal protection standard Switching frequency 100KHz Input with PFC : (MML400PFC, MML600, MML800) Input voltage range 85*-264VAC Inrush current (peak) MML400PFC < 35A MML600 < 20A MML800 < 55A Power factor > 0.9 Start up time (max.) MML400PFC < 700 msec MML600,800 < 1500 msec Inrush current MML400PFC < 35A MML600 < 20A MML800 <55A Start up time (max.) MML400 < 900 msec GENERAL Power 400 to 800W Efficiency < 73% Line & configuration dependent Voltage isolation : Input-output 3.0KV RMS Input-ground 1.5KV RMS Output-ground 500VDC Input/output resistance 30Mohms/ 500VDC AC power fail Opto isolated input standard on MML600, 800, MML400PFC 400-800 Inhibit Opto isolated input standard on MML600, 800, MML400PFC WATTS POWER SUPPLY AC/DC ENVIRONMENTAL Operating temperature 0°C at + 70°C SINGLE OR Derating 400W and 800W : 100% upto 50°C then 2.5%/°C MULTIPLE OUTPUT 600W : 100% upto 45°C then 2%/°C Flexible modular design Operating/storage humidity (non condensing) 5% to 95% HR Programmable outputs** Operating/storage pressure 1030 to 680 millibars Power factor correction*** EMC EN 55022 class A or B configuration dependent Universal input 85-264 VAC* (1) EMI EN55022 curve B Guarantee 3 years * Consult Techical Sales for maximum power available **See programmable modules ***Models MML400PFC, MML600, MML800 (1) option on certain models EDITION 2001 OUTLINE SPECIFICATION OUTPUT Module table (nominal output values) Type of module A B C D E F G H J K L Slot width (1 slot = 23 mm) 2 1 1 1 1 2 2 1 2 1 3 Output voltage 5V 5V 12V 24V 12V/12V 12V 24V 24V/24V 48V 12V/12V 5 Adjustment range 2-6V 2-6V 5-15V 12-28V 5-15V 5-15V 12-28V 12-28V 25-60V 5-15V 2-6V 2 2 2 Output current 60A 25A 12A 7A 6A 24A 15A 3,5A 10A 6A 100 1 1 Load regulation (0-100%) 0.1% 0.1% 0.1% 0.1% 0.5% 0.1% 0.1% 0.5% 0.1% 0.5% 0.2% Adjustment Multi turn potentiometer Setting accuracy ±1% Temperature coefficient 0.02%/°C Line regulation 0.1% for ±20% of nominal mains Ripple & noise (PARD) 50mV or 1% whichever is greater (A B CDFGJ L). 1% typical twin o/p Note 4 Transient response Max.deviation <7.5% of set volts recovering to 1% within 300 microseconds Overcurrent protection Non foldback/fold back option Overvoltage protection Tracking 120% of set voltage on A BCDEFGL fixed on E H K Remote sense 0,5 volts total (not E H K) Output isolation 500 VDC / ground 1. 10 - 100% load 2. Total current shared between both outputs 3. Modules E H K have fixed overvoltage clamp, typcially 18V for E and K, 35V for H 4. 50mV up to 6A/channel, 10mV up to 1A/channel (K module only) PROGRAMMABLE MODULES (Series BP and DP) Omega programmable modules offer ideal flexible solutions for ATE GENERAL applications. Because of their compatibility with all standard Omega modules Power 150W (derating 2W/°C >25°C for BP). they can be combined within the same power supply giving total output power Please consult Technical Sales of up to 800 Watts. Dimensions 23mm per module Operating temperature 0-50°C no derating 50-70°C derating 2.5%/°C MODE OF PROGRAMMING Resistance voltage programming Resistance 1KΩ/V Programming accuracy Voltage 0-5V Voltage ± 0,1% Current ± 10% Current programming A voltage of 0-5 volts on the current control pins will programme current limit from 10% Minimum load To achieve voltages of <1V external bleed - 100% of full load current of 500mA of 500mA required Overcurrent protection non-programmable 105-130% I nom SIGNAL CONTROL (on certain modules) programmable 10-110% I nom “Enable” Logic input referenced to V out -VE Overvoltage protection 115%-125% tracking “Power good” Open collector, ouput voltage within +/- Remote sense 0.25V max. each line 10% of programmed value. Transistor on. Sink capability 1mA + <1V Series OMEGA Series OMEGA EDITION 2001 TABLE OF PROGRAMMABLE MODULES Series BP Series DP Modules BP1 BP2 BP3 BP4 BP5 BP6 DP1 DP2 DP3 DP4 DP5 DP6 DP7 DP8 Output voltage (V) 0.15V - 6V 0.25V - 30V (DP3 : 0.25 - 15V) Current (A) 0-25 25 25 0-25 0-25 20 0-5 7 2 0-5 0-5 0-2 7 7 Voltage programming 1kΩ/ V •• ••••• • • • 0-5V •••••••••••••• Current programming (0-5V) • • • • ••• OVP trackingext.ext. ext.int.ext.ext. int.ext.int. fixed int. int. int. ext. ext. Signal options ENABLE •••• • OUTPUT GOOD•• Line regulation ± 15 mV ± 15 mV Load regulation ± 15 mV ± 15 mV Ripple & noise 60 mV 200 mV OPTIONS OPTIONS PRIMARY SECONDARY OPTIONS (continued) (Standard on MML600, 800) Inhibit / Enable Factory configurable for module inhibit/enable - hi or lo. Pin is connected to Mains fail Isolated signal from opto-coupler. Ouput 0 volts or +VE ouput to effect control signal can sink a maximum of 10mA to allow a 5 milli-second hold-up from VME AC fail, system reset, powergood activation of mains signal until power compatible with VME bus supply drops out of limit (modules A B & L) Converter inhibit Power supply inhibited by applying 7.5mA Output connections via 4 pin molex through an opto-isolated input MML400 PFC Inhibit - TTL lo (0.4) to inhibit 0.4-60V max to turn on from an Suffix Function internal isolated (5V, 40mA) supply. This Y5 “Starpoint” + starpoint and module good supply may be used as an additional Y6 “Power good” + Inhibit (hi or lo) output if required for inhibit function Y7 “Power good” + Enable (active hi) MML400 PFC Mains Fail - Open collector Y8 “Power good” + Enable (active lo) output can be connected to any external voltage up to 60V CASE OPTIONS U Case: An alternative case form is available with the output terminal along the 127mm OPTIONS SECONDARY dimension and opposite the mains input Starpoint Single wire interconnect forces parallelled and fan (not available on MML800). modules to share current at greater than (example MML400U) 15% load, modules share within 6% of current determined by current limit sharing DD Case: 600W version available in a 127 x 127 x “Power good” Detects output voltage high or low (+/-10%) 241mm case (example MML600DD). from set output volts Series OMEGA Series OMEGA EDITION 2001 TABLE OF STANDARD MODELS Maximum Module Number Model Case power Output N°1 Output N°2 Output N°3 Output N°4 Output N°5 line up of slots Watts Volts Amp. Volts Amp. Volts Amp. Volts Amp. Volts Amp. MML 400 B1 400 360 5 60 A 2 MML 400 C1 400 400 5 80 A + B (Parallel) 3 MML 400 B2 400 400 24 15 G 2 MML 400 B3 400 360 12 24 F 2 MML 400 D1 400 400 5 60 12 12 12 12 A + C + C 4 MML 400 E1 400 400 5 60 12 12 12 12 24 7 A + C + C + D 5 MML 400 E2 400 400 5 60 12 12 12 12 5 12 A + C + C + B 5 MML 400 PFC B1 400 360 5 60 A 2 MML 400 PFC C1 400 400 5 80 A + B (Parallel) 3 MML 400 PFC B2 400 400 24 15 G 2 MML 400 PFC B3 400 360 12 24 F 2 MML 400 PFC D1 400 400 5 60 12 12 12 12 A + C + C 4 MML 400 PFC E1 400 400 5 60 12 12 12 12 24 7 A + C + C + D 5 MML 400 PFC E2 400 400 5 60 12 12 12 12 5 12 A + C + C + B 5 MML 600 T1 600 600 5 120 A + A (Parallel) 4 MML 600 T2 600 600 24 25 G + G (Parallel) 4 MML 600 T4 600 600 48 12.5 J + J (Parallel) 4 MML 600 T5 600 600 5 60 12 12 12 12 A + C + C 4 MML 600 U3 600 600 5 80 12 12 12 12 A + B (Par) + C + C 5 MML 800 V1 800 800 24 30 G + G (Parallel) 4 MML 800 V2 800 800 48 16.5 J + J (Parallel) 4 NB: All outputs are user adjustable over the range shown in the module table. However, it may not be possible to draw full o/p power of an individual module if the total power exceeds the converter power. Request Omega application note No. 2 for futher details. Series OMEGA Series OMEGA EDITION 2001 CONFIGURED (MODULAR) UNITS If you cannot find a standard Omega unit which fully meets your Volts Amps Watts Module Number of slots requirements, the Lambda UK Technical Sales support team will 28 3,25 91 D 1 create a customised modular unit utilising the standard modules. If 5 25 125 B 1 your requirements are straightforward you can configure the unit 56 30 B 1 yourself. First list all required output voltage and current ratings (all 12 4 48 C 1 outputs are fully floating - hence polarity can be ignored), multiply the 24 3 72 D 1 voltage and current together to calculate power in watts for each output. Add together all the output powers to arrive at the total N.B. : One slot width = 23 mm wattage in this example the total power is 366W. 4. Now list the converter followed by the modules selected in Volts Amps Watts descending order of current rating 28 3,25 91 Example : MML 400 5B 5B 12C 28D 24D. 5 25 125 This is the part number of your customised unit 56 30 12 4 48 In addition there are options available for either the converter or each 24 3 72 of the modules separately, consult the options table for details. If you need the converter or primary option, enter an ‘X’ after the converter Total power : 366 i.e. MML400 X. If you need the parallelling option on the 28 volt Now proceed as follows: output enter Y5 after the module i.e. MML400 X 5B5B12C28DY524D 1. Select either 400, 600 or 800 watt converter. In the example a 400 watt would be required. 2. Now refer to the module table and select a unit to meet the requirements of the first output in the example, this is 28 volts at 3.25 amps, so a ‘D’ module would be suitable. Prefix this with the required voltage (in this case 28). This gives the module specification as 28D. TABLE OF DIMENSIONS Model Number A B Weight of slots (mm) (mm) (kg) MML400 2 212 156 1,6 MML400PFC 2 212 156 1,6 MML600 2 257 202 2,35 MML400 3 235 179 1,8 MML400PFC 3 235 179 1,8 MML600 3 280 225 2,55 MML400 4 257 202 2,0 MML400PFC 4 257 202 2,0 MML600 4 303 248 2,75 MML800 4 329 283 3,8 MML400 5 280 225 2,2 MML400PFC 5 280 225 2,2 MML400U/PFC 5 280 104 2,2 MML600 5 326 271 2,95 MML600U 5 326 150 2,95 MML800 5 352 306 4,0 MML600 6 349 294 3,15 MML800 6 375 329 4,2 MML800 7 398 352 4,4 MML800 8 421 375 4,6 Refer to module table for slot width Series OMEGA EDITION 2001 CONNECTIONS Input terminal block with 6-32 screws (400/400PFC) 8-32 screws (600/800) DC Outputs Screw terminals (M6 slot 46mm modules) (M4 1 slot 23mm) (M3 twin modules) Remote Sense Screw terminals M3 Primary options Molex housing 50-37-5043 (PIN 08-70-1040) Secondary options Molex 39-01-2040 (PIN 39-00-0032) PRIMARY OPTIONS MML400, 600 : MML 400PFC, X2 MML800 : Pin 4 Powerfail - Pin 4 0V Pin 3 Powerfail + Pin 3 Mains fail Pin 2 Inhibit + Pin 2 5V Pin 1 Inhibit - Pin 1 Inhibit o Pin N 4 3 2 1 SECONDARY OPTIONS Y5 SECONDARY OPTIONS Y6, Y7 AND Y8 Pin 1 : Startpoint Parallel* Pin 1 : Inhibit High (Y6) / Enable Low (Y8) Pin 2 : Inhibit Low (Y6) / Enable High (Y7) Pin 2 : Startpoint Parallel* Pin 4 : Power Good (-) Pin 4 : Module Good (-) Pin 3 : Power Good (+) Pin 3 : Module Good (+) OPTIONS VME Pin 1 : AC Fail Pin 2 : System reset Pin 4 : Ground Pin 3 : Power Good OMEGA DC INPUT SERIES Max. Model Case Length power Output N°1 Output N°2 Output N°3 Output N°4 Watts Volts Amp. Volts Amp. Volts Amp. Volts Amp. Modules MML 400 DCB1 600 258 360 5 60 A MML 400 DCC1 600 281 400 5 80 A + B (Parallel) MML 400 DCB2 600 258 400 24 15 G MML 400 DCB3 600 258 360 12 24 F MML 400 DCD1 600 304 400 5 60 12 12 12 12 A + C + C MML 400 DCE1 600 327 400 5 60 12 12 12 12 24 7 A + C + C + D MML 400 DCE2 600 327 400 5 60 12 12 12 12 5 12 A + C + C + B INPUT Input voltage range 36-190VDC Inrush current tba Input protection fuse Thermal protection standard PRIMARY/SECONDARY CASE OPTIONS see MML 600AC Series OMEGA EDITION 2001 PHYSICAL SPECIFICATION CASES 400 - 600 IMPORTANT: Maximum penetration of mounting screws not to exceed 5mm M4 Rear fixing M4 Rear fixing Air flow B M4 Base fixing centres CASE 800 IMPORTANT: Maximum penetration of mounting screws not to exceed 5mm 8-way including fan guard Air flow Top view showing fixing centres on bottom face Front view showing fixing centres on rear face Input connector Series OMEGA EDITION 2001 M4 80mm fixing centres PHYSICAL SPECIFICATION (continued) CASE U CASE 600DD Maximum penetration of M4 fixings not to exceed 6.35mm Series OMEGA EDITION 2001

Frequently asked questions

What makes Elite.Parts unique?

chervon down
At GID Industrial (Elite.Parts' parent company), we specialize in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

What kind of warranty will the MML-600-DD-T2 have?

chervon down
Warranties differ by part and by which suppliers we use to procure it for you. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carriers does Elite.Parts work with?

chervon down
Elite.Parts can ship via FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Will Elite.Parts sell to me even though I live outside the USA?

chervon down
Absolutely! We are happy to serve customers regardless of location. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

I have a preferred payment method. Will Elite.Parts accept it?

chervon down
All major credit cards are accepted: Visa, MasterCard, Discover, and American Express. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

Lambda MBS-1215-22 Filter - FILTER NOISE 250V/15A 50/60HZ TV2500V/1MIN

Lambda MBS-1220-33 Noise Filter

Lambda MLGS-5A Series Single Output High Reliability AC-DC Industrial Switching Power Supply

Lambda MLGS-5A-12-OV 312W 12V / 26A (Adjustable Vout Range of 11.4V ~ 12.6V) Single Output High Reli...

Lambda MLGS-5A-15-OV 330W 15V / 22A (Adjustable Vout Range of 14.25V ~ 15.75V) Single Output High Re...

Lambda Power Supply