LAMBDA HWS1000-15
Specifications
Adjustment Range
12 - 18V
Efficiency
83/85%
Hold Up Time (Typ)
ms 20
Input Current (Typ)
3.3V: 9.6/5.0;5-60V: 13.5/7.0
Input Voltage range
(47-63Hz)
Inrush Current
A 20 / 40
Line Regulation
60A
Load Regulation
120A
Max Current
70A
Max Power
1050A
Over Voltage
18.8 - 21.8V
Overcurrent Protection
>105% (>101% of peak current for peak current capable models)
Peak Current
80A
Power Factor
Meets EN61000-3-2
Ripple Noise
150A
Size (WxHxD)
5 x 3.25 x 9.45”
Voltage
15V
Weight (Typ)
3,200g
Features
- Class 1 Div 2 option (/RY suffix)
- High Efficiency
- SEMI F47 Compliant (high line AC)
- UL508 approved
- Universal Input (85 - 265VAC)
- Wide Range AC Input
Datasheet
Extracted Text
HWS300-1500 Series Single Output Industrial Power Supplies Features u Limited Lifetime Warranty u UL508 approved u SEMI F47 Compliant (high line AC) u Universal Input (85 - 265VAC) u High Effi ciency u Class 1 Div 2 option (/RY suffi x) u Wide Range AC Input Key Market Segments & Applications Specifi cations Model HWS300 HWS600 HWS1000 HWS1500 Input Voltage range (47-63Hz) - 85 - 265VAC or 120 - 330VDC (6) Input Current (Typ) (1) A 5V: 3.8/1.9; 5V: 7.5/3.6; 3.3V: 9.6/5.0; 3.3V: 15.0/8.0; 12-48V: 4.2/2.1 12-48V: 8.1/3.9 5-60V: 13.5/7.0 5-60V: 19.5/10.0 Inrush Current (1) A 20 / 40 Power Factor - Meets EN61000-3-2 Temperature Coeffi cient - <0.02%/°C Overcurrent Protection - >105% (>101% of peak current for peak current capable models) Overvoltage Protection V See table on page 2 (Recycle AC or remote on/off to reset) Hold Up Time (Typ) ms 20 Leakage Curr. (at 240VAC, 60Hz) mA <0.75mA <1.2mA <1.5mA Remote Sense - Yes Indicator - Green LED = ON Remote on/off - Yes (Isolated from output) Parallel operation - Single wire connection (up to 5 units) DC Good - Yes Remote Adjust (PV) - External voltage adjusts output, see options table Operating Temperature - -10°C to +70°C, derate linearly to 50% load from 50C to 70C (2, 3) Storage Temperature °C -30 to +85°C Humidity (non condensing) - Operating: 10 - 90%RH, Non operating 10 - 95%RH Cooling - Internal fan Withstand Voltage (4) - Input to Ground 2.5kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min. Isolation Resistance - >100M at 25°C & 70%RH, Output to Ground 500VDC 2 Vibration (non operating) - 10 - 55Hz (1 minute sweep), 19.6m/s constant X, Y, Z 1 hour 2 Shock - < 196.1 m/s Safety Agency Certifi cations (5) - UL60950-1, CSA60950-1, EN60950-1, EN50178, UL508, CE Mark Line Dip - Complies with SEMI F47 (200VAC line only) Conducted & Radiated EMI - EN55011 / EN55022, FCC VCCI (HWS300, 600 & 1000: Class B, HWS1500: Class A) Immunity - IEC61000-4-2, -3, -4, -6 (Level 3), -5, -8 (Level 4), -11 Weight (Typ) g 1,000 1,600 3,200 3.3-7.5V: 4000; 12V+: 3800 Size (WxHxD) in 2.4 x 3.23 x 6.5” 3.94 x 3.23 x 6.5” 5 x 3.25 x 9.45” 5 x 3.25 x 11” Warranty yrs Limited lifetime warranty (See TDK-Lambda’s terms and conditions) (1) 100/200VAC (5) UL60601-1, EN60601-1, see options. (2) HWS start up -20°C. (-40°C see options table) UL508; HWS300/600 5V, 12V, 24V & 48V models (3) HWS1000/1500 with 85VAC input: See installation manual (6) Not on HWS1500/ME, /HD or /RY versions (4) 2kVAC HWS1000/1500 Input to ground (*) Class 1 Div 2 option (/RY suffi x) HWS1000: -10 to +71°C. HWS1000-5, HWS1500-3, -5 derate linearly above 40°C 1-800-526-2324 • www.us.tdk-lambda.com/lp/ 61 Disclaimer: us.tdk-lambda.com/lp/legal.htm HWS300-1500 Series Output Ratings Adjust Max Peak Max. Load Line Ripple Over- Eff. Voltage Range Curr. Curr. Pwr. Reg Reg Noise voltage typ Model V V(3) A A(2) W mV mV mV V % (1) HWS300-3 3.3V 2.64 - 3.96 60 - 198 30 20 120 4.13 - 4.95 74/77 HWS600-3 3.3V 2.64 - 3.96 120 - 396 30 20 120 4.13 - 4.95 75/78 HWS1000-3 3.3V 2.64 - 3.96 200 - 660 40 20 120 4.13 - 4.62 71/73 HWS1500-3 3.3V 2.64 - 3.96 300 - 990 60 36 150 4.12 - 4.62 72/75 HWS300-5 5V 4 - 6 60 - 300 30 20 120 6.25 -7.25 79/82 HWS600-5 5V 4 - 6 120 - 600 30 20 120 6.25 -7.25 80/83 HWS1000-5 5V 4 - 6 200 - 1000 40 20 120 6.25 - 7.0 76/78 HWS1500-5 5V 4 - 6 300 - 1500 60 36 150 6.25 - 7.0 77/81 HWS1000-6 6V 4.8 - 7.2 167 - 1002 60 36 150 7.5 - 8.4 79/81 HWS1500-6 6V 4.8 - 7.2 250 300 1500 60 36 150 7.5 - 8.4 79/82 HWS1000-7 7.5V 6 - 9V 134 160 1005 60 36 150 9.38 - 10.5 80/82 HWS1500-7 7.5V 6 - 9V 200 240 1500 60 40 150 9.37 - 10.5 81/83 HWS300-12 12V 9.6 - 14.4 27 - 324 96 48 120 15 - 17.4 80/83 HWS600-12 12V 9.6 - 14.4 53 - 648 96 48 120 15 - 17.4 80/83 HWS1000-12 12V 9.6 - 14.4 88 100 1056 100 48 150 15 - 17.4 83/85 HWS1500-12 12V 9.6 - 14.4 125 - 1500 72 48 150 15 - 17.4 82/85 HWS300-15 15V 12 - 18 22 - 330 120 60 150 18.8 - 21.8 82/85 HWS600-15 15V 12 - 18 43 - 645 120 60 150 18.8 - 21.8 82/85 HWS1000-15 15V 12 - 18 70 80 1050 120 60 150 18.8 - 21.8 83/85 HWS1500-15 15V 12 - 18 100 - 1500 90 60 150 18.7 - 21.8 83/87 HWS300-24 24V 19.2 - 28.8 14 16.5 336 192 96 150 30 - 34.8 82/85 HWS600-24 24V 19.2 - 28.8 27 31 648 192 96 150 30 - 34.8 82/85 HWS1000-24 24V 19.2 - 28.8 44 50 1056 150 96 150 30 - 34.8 85/87 HWS1500-24 24V 19.2 - 28.8 65/70 (1) 105 1560 144 96 200 30 - 34.8 84/88 HWS1000-36 36V 28.8 - 43.2 29.3 33.3 1055 150 144 200 45 - 49.7 85/88 HWS1500-36 36V 28.8 - 43.2 42/46.5 (1) 70 1512 150 144 200 45 - 49.7 84/88 HWS300-48 48V 38.4 - 52.8 7 - 336 384 192 200 55.2 - 64.8 82/85 HWS600-48 48V 38.4 - 52.8 13 - 624 384 192 200 55.2 - 64.8 82/85 HWS1000-48 48V 38.4 - 52.8 22 25 1056 300 192 200 55.2 - 64.8 86/88 HWS1500-48 48V 38.4 - 52.8 32 - 1536 288 192 200 55.2 - 64.8 86/90 HWS1000-60 60V 48 - 66 17.6 20 1056 360 240 400 69 - 75 85/88 HWS1500-60 60V 48 - 66 25.6/28 (1) 42 1536 360 240 400 69 - 75 86/90 Notes (1) 100/200VAC (2) 200-265VAC Input, 10s maximum on time with 35% duty cycle (3) Use program input (PV) to adjust from 20-120% of nominal (20-110% for 48V models) Options Other Industrial Products Suffi x Description HWS 15W to 150W single output Blank HWS300-1500 the cover is fi tted as standard LZSA 500W to 1500W Single output /A Not Applicable SWS 50W to 1000W, low cost HWS300-1500 the cover is fi tted as standard DPP, DLP & DSP 10W to 480W DIN Rail Mount /PV HWS300, 600 (Standard on HWS1000 & 1500): 1-6V program voltage input to adjust output 20-120% of nominal (20-110% for 48V) (12V-48V models only) For Additional Information, please visit /HD See HWS50-1500/HD Datasheet for details.-40 to +71(74)°C operation, conformally coated PCBs us.tdk-lambda.com/lp/products/hws-series.htm /ME See HWS30-1500/ME Datasheet for details. UL60601-1, EN60950-1 medical certifi cation /RY ISA 12.12.01 (UL1604) - Class 1 Div 2 with dry contact relay DC Good signal (300W, 600W and 1500W 24V output models only, no UL508 certifi cation, no remote on/off function.) 1-800-526-2324 • www.us.tdk-lambda.com/lp/ 62 Revision C4: Dec 2011
Frequently asked questions
What makes Elite.Parts unique?

What kind of warranty will the HWS1000-15 have?

Which carriers does Elite.Parts work with?

Will Elite.Parts sell to me even though I live outside the USA?

I have a preferred payment method. Will Elite.Parts accept it?

Why buy from GID?

Quality
We are industry veterans who take pride in our work

Protection
Avoid the dangers of risky trading in the gray market

Access
Our network of suppliers is ready and at your disposal

Savings
Maintain legacy systems to prevent costly downtime

Speed
Time is of the essence, and we are respectful of yours
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods