KIMMON QUARTZ NDR-6W
Features
- Accuracy: Within ±±1.5% (4L/h to 20L/h)
- Connection: 8mm (15A gas pipe or 8mm copper pipe), Adaptors accept 1/8" male NPT fitting
- Flow Range: 0.1L/h - 20L/h
- Inlet: Left
- Inside diameter: 8 mm
- Maximum registration: 99999.99 liter
- Maximum working pressure: 0.1MPa (1.0kgf/cm²) (1 atm)
- Maximum working temperature: 45°C
- Minimum Registration: 0.00% L
- Minimum scale: 0.02 liter
- Weight: 1.3 kg
Datasheet
Extracted Text
9/6/12 Flow Totalizer **** Kimmon Flow Totalizer (Drip Meter) Discontinued **** Below the MICROSTREAM Flow meter is the new replacement. MICROSTREAM Flow meter Instantaneous Flow-Rate Integrating Flow Volume Flow meter Model: OF-WN (Local display type) Model: OF-WP (With pulse output) Features Built-in lithium batteries (No external power supply is required) Indications of both instantaneous flow-rate and integrating flow volume by only 1 flow meter Revolving display unit (It can be fixed to a easy-to-read position) Simplified structure with the oval gears type measuring principle Measurement of various liquids Reset function for indications of Integrating Flow Volume (Total) and Integrating Flow Volume (Trip) Value holding function for Instantaneous Flow-Rate indication Pulse output function (Option) Specifications Instantaneous flow-rate・ Integrating flow volume OF05ZAWN OF10ZAWN flow meter OF-WN Type Instantaneous flow-rate・ Integrating flow volume OF05ZAWP OF10ZAWP flow meter (with pulse output) OF-WP Type Fluid viscosity 0.085 ~ 0.85L/min 0.7 ~ 5L/min 0.3 ~ 0.8mPa·S Flow-rate 0.8 ~ 2.0mPa·S 0.05 ~ 0.85L/min 0.35 ~ 5L/min 3 range (m /h) 2.0 ~ 5.0mPa·S 0.017 ~ 0.85L/min 0.17 ~ 5L/min 5.0 ~ 200mPa·S 0.0085 ~ 0.85L/min 0.085 ~ 5L/min Accuracy Flow-rate indication ±2%RS±0.007L/min ±2% RS±0.04L/min (*1) Volume indication ±2%RS Please select with reference to the following major materials Measurable Various liquids of the liquid-touching materials fluids Major fluids Water, hot water, kerosene, heavy oil Max. working pressure 0.5MPa (at the time of fluid temperature of 20°C) Pressure drop Not more than 4kPa Not more than 10kPa Fluid temperature range 0 ~ +60°C Open drain output (Equivalent to open collector) Pulse width: Not less than 5ms Max. rating voltage: 30VDC Output signal (for OF-WP) Output capacity: “ON resistance” Not more than 150Ω, “OFFresistance” Not less than 100kΩ (Remained voltage not more than 1.5V in case of input current not more than 10mA) Pulse unit (for OF-WP) 10mL/p 0 ~ +60°C 35 ~ 85%RH Ambient temperature range (Dew condensation must be avoided) Smallest Scale0.007L/min 0.04L/min Flow-rate Display digits 0.000L/min 00.00L/min LCD Smallest Scale0.001L 0.01L Volume Display digits 00000.000L 000000.00L Power supply Built-in lithium battery (Battery life 4 years. Not replaceable.) Structure IP64 equivalent, Indoor installation Connection R1/4 R1/2 Meter Weight Approx. 240g Approx. 260g Casing PPS Major materials Rotor PPS of the liquid O-ring NBR touching parts C:/Documents and Settings/Mehmet/My Documents/kimmonquartzeskihali/htdocs/Pages/FlowTotalizer.htm 1/8 9/6/12 Flow Totalizer Pivot SUS304 Instantaneous flow-rate・ Integrating flow volume OF05ZZWN OF10ZZWN flow meter OF-WN Type Instantaneous flow-rate・ Integrating flow volume OF05ZZWP OF10ZZWP flow meter (with pulse output) OF-WP Type Fluid viscosity 0.085 ~ 0.85L/min 0.7 ~ 5L/min 0.3 ~ 0.8mPa·S Flow-rate 0.8 ~ 2.0mPa·S 0.05 ~ 0.85L/min 0.35 ~ 5L/min 3 range (m /h) 2.0 ~ 5.0mPa·S 0.017 ~ 0.85L/min 0.17 ~ 5L/min 5.0 ~ 200mPa·S 0.0085 ~ 0.85L/min 0.085 ~ 5L/min Accuracy Flow-rate indication ±2%RS±0.007L/min ±2% RS±0.04L/min (*1) Volume indication ±2%RS Please select with reference to the following major materials Measurable Various liquids of the liquid-touching materials fluids Major fluids Water, hot water, kerosene, heavy oil Max. working pressure 0.5MPa (at the time of fluid temperature of 20°C) Pressure drop Not more than 4kPa Not more than 10kPa Fluid temperature range 0 ~ +60°C Open drain output (Equivalent to open collector) Pulse width: Not less than 5ms Max. rating voltage: 30VDC Output capacity: “ON resistance” Not more than 150Ω, Output signal (for OF-WP) “OFFresistance” Not less than 100kΩ (Remained voltage not more than 1.5V in case of input current not more than 10mA) Pulse unit (for OF-WP) 10mL/p 0 ~ +60°C 35 ~ 85%RH Ambient temperature range (Dew condensation must be avoided) Smallest Scale0.007L/min 0.04L/min Flow-rate Display digits 0.000L/min 00.00L/min LCD Smallest Scale0.001L 0.01L Volume Display digits 00000.000L 000000.00L Power supply Built-in lithium battery (Battery life 4 years. Not replaceable.) Structure IP64 equivalent, Indoor installation Connection R1/4 R1/2 Meter Weight Approx. 240g Approx. 260g Casing PPS Major materials Rotor PPS of the liquid O-ring FKM touching parts Pivot SiC In case there is possibility that any particle is flown in the liquid to be measured, please install a filter of not less than 80 meshes at the inlet side of the flowmeter. Gasoline, Sodium hydroxide (Caustic soda), Hydrogen peroxide solution (Oxydol), and Hydrochloric acid are not applicable. *1: With the standard installation position. External dimensions Model OF05 OF10 A(mm) 80 90 B(mm) 8 8.5 C(mm) 25 24 Standard installation position C:/Documents and Settings/Mehmet/My Documents/kimmonquartzeskihali/htdocs/Pages/FlowTotalizer.htm 2/8 9/6/12 Flow Totalizer Materials - Abbreviations PPS Polyphenylene Sulfide Resin NBR Acrylonitrile-Butadiene Rubber SUS304Stainless Steel 304 FKM Fluoro Rubber SiC Silicon Carbide Ceramic Specifications are subject to change without notice. FLOW SENSOR WITH INDICATORS Instantaneous Flow-rate Integrating Flow Volume Flow meter Model: NW (Local display type) Model: NW-P (With pulse output) Features Specifications Built-in lithium batteries (No external power supply is required) Instantaneous flow-rate· Indications of both instantaneous flow-rate and integrating flow volume by only 1 flow meter Integrating flow volume NW05-NTN NW05-PTN NW05-TTN NW10-NTN flow meter NW Type Revolving display unit (It can be fixed to a easy-to-read position) Instantaneous flow-rate· Simplified structure with the vane wheel type measuring principle Integrating flow volume Measurement of various liqN ui W ds 05-NTP NW05-PTP NW05-TTP NW10-NTP flow meter (with pulse output) Reset function for indications of Integrating Flow Volume (Total) and Integrating Flow Volume (Trip) NW-P Type Value holding fu 3nction for Instantaneous Flow-Rate indication 0.3 – 3L/min 1.5 – 20L/min Flow-rate range (m /h) Pulse output function (Option) ±2% Flow-rate indication ±2%RS±0.05L/min Accuracy RS±0.2L/min Volume indication ±2%RS (with the standard installation position) Various liquids (Please select with reference to Measurable fluids the following major materials of the liquid-touching materials) Max. Working Pressure 1MPa (at the time of fluid temperature of 20°C) Not more than Not more than 12kPa 20kPa Pressure Drop (At the time of 3L/min) (At the time of 20L/min) Fluid viscosity range 0.5-1.5mPa・s Fluid temperature range 0±60°C Ambient temperature range 0±60°C 35-85%RH(Dew condensation must be avoided) Open drain output (Equivalent to open collector) C:/Documents and Settings/Mehmet/My Documents/kimmonquartzeskihali/htdocs/Pages/FlowTotalizer.htm 3/8 9/6/12 Flow Totalizer Pulse width: Not less than 5ms Max. rating voltage: 30VDC Output signal (for NW-P) Output capacity: “ON resistance” Not more than 150Ω, “OFFresistance” Not less than 100kΩ (Remained voltage not more than 1.5V in case of input current not more than 10mA) Pulse unit (for NW-P) 10mL/p 1L/p Smallest Scale0.05L/min 0.2L/min Flow-rate LCD Display digits 00.00L/min 000.0L/min Volume Display digits 000000.00L 0000000.0L Power supply Built-in lithium battery (Battery life 4 years. Not replaceable.) Measurable fluids Refer to "MEASURABLE FLUID AND PARTS MATERIALS" Structure IP64 equivalent, Indoor installation Connection R1/2 Meter Weight Approx. 280g Approx. 250g Denatured Denatured Casing PP ETFE PPO PPO Major materials Vane wheel POM ETFE POM of the liquid Pivot SUS304 PA ETFE SUS304 touching parts O-ring NBR FKM NBR Magnet Sa-Co *1 Ba-Fe Instantaneous flow-rate· Integrating flow volume NW10-PTN NW10-TTN NW20-NTN NW20-PTN flow meter NW Type Instantaneous flow-rate· Integrating flow volume NW10-PTP NW10-TTP NW20-NTP NW20-PTP flow meter (with pulse output) NW-P Type 3 1.5-20L/min 1.0-10L/min 3.0-60L/min Flow-rate range (m /h) Flow-rate indication ±2%RS±0.2L/min ±2% RS±0.5L/min Accuracy Volume indication ±%RS (with the standard installation position) Various liquids (Please select with reference to Measurable fluids the following major materials of the liquid-touching materials) Max. Working Pressure 1MPa (at the time of fluid temperature of 20°C) Not more than Not more than 20kPa 15kPa Not more than 60kPa Pressure Drop (At the time of (At the time of (At the time of 60L/min) 20L/min) 10L/min) Fluid viscosity range 0.5-1.5mPa·s Fluid temperature range 0±60°C Ambient temperature range 0±60°C 35-85%RH(Dew condensation must be avoided) Open drain output (Equivalent to open collector) Pulse width: Not less than 5ms Max. rating voltage: 30VDC Output signal (for NW-P) Output capacity: “ON resistance” Not more than 150Ω, “OFF resistance” Not less than 100kΩ (Remained voltage not more than 1.5V in case of input current not more than 10mA) Pulse unit (for NW-P) 1L/p Smallest Scale0.2L/min 0.5L/min Flow-rate LCD Display digits 000.0L/min Volume Display digits 0000000.0L Power supply Built-in lithium battery (Battery life 4 years. Not replaceable.) Measurable fluids Refer to "MEASURABLE FLUID AND PARTS MATERIALS" Structure IP64 equivalent, Indoor installation Connection R1/2 R3/4 Meter Weight Approx. 250g Approx. 500g Denatured Casing PP ETFE PP PPO Major materials Vane wheel POM ETFE POM of the liquid Pivot SUS304 ETFE SUS304 touching parts O-ring FKM NBR FKM Magnet Ba-Fe Sa-Co *1 Ba-Fe Any installation position other than the standard installation position is not available for NW05-TTN, NW05-TTP, NW10-TTN, and NW10-TTP. *1: The magnet does not touch liquid. External dimensions Mode NW05NW10 NW20 A(mm) 80 80 110 B(mm) 87 87 105.5 C(mm) 52 52 74 D(mm)11 11 16 E(mm) 25 25 35.5 C:/Documents and Settings/Mehmet/My Documents/kimmonquartzeskihali/htdocs/Pages/FlowTotalizer.htm 4/8 9/6/12 Flow Totalizer Standard installation position The standard installation position is that the display is facing upwards. * The display is able to be revolved. Materials -Abbreviations Denatured PPO Denatured Polyphenylene oxide PP Polypropylene ETFE Ethylene-tetrafiuoro ethylene POM Polyacetal or Polyoxymethylene SUS304 Stainless steel 304 PA Polyamide NBR Acrylonitrile-Butadiene Rubber FKM Fluoro Rubber Sa-Co Samarium-Cobalt Ba-Fe Barium-ferrite Specifications are subject to change without notice. Kimmon Flow Totalizer (Drip Meter) Discontinued Even drips can be measured with high accuracy 1. Introduction The central heating system lately popularized for home heating depend mostly on the method to supply hot water through a boiler using kerosene as a fuel. In an apartment house, the fuel oil is pumped up from underground tank to roof tank and then fed to a service tank of each home by natural downstream force. The fuel oil in the service tank is to be fed afterward to the burner of a boiler with head difference of around 2 meters (6-feet). The capacity of the service tank is less than 30 liters and the flow rate is so small as 0.5 to 10 liter/h. In order to measure the fuel consumption of each home, accordingly, there is no other way to measure the practical feeding quantity of fuel by means of oil meter between the service tank and the hot-water boiler. Flow meter NDR-6W (so called the drip meter) is developed for the purpose of measuring such small flow of fuel oil and is characterized by Japan's first oil measuring meter. This meter can be applied to a wide variety of fluids required very small amount measured such as water analysis for nuclear reactors, greenhouse heating systems, small size boilers and diesel engines, and etc. 2. Construction and principle of operation The diaphragm chamber of this meter consist of two aluminum boxes facing in parallel and each of them is divided with a diaphragm into two sections. The respective sections are assembled at a phase difference of some 90° and connected with the inlet or the outlet by the valve which alternates the fuel route sliding on the valve seat. The new fluid, entering one section, is to press the diaphragm and send out the old fluid in the opposite section. C:/Documents and Settings/Mehmet/My Documents/kimmonquartzeskihali/htdocs/Pages/FlowTotalizer.htm 5/8 9/6/12 Flow Totalizer At the dead point, the section connected with the outlet will be replaced to the inlet and the diaphragm is to move in the contrary direction. This reciprocating diaphragm movement is is converted with a link to a rotational movement that turns the registration mechanism indicating the volume passed. 3. Features Head Loss is very low: Conventional piston type and single-valve type flow meters have suffered from high head loss (for instance, over 200 mmAq at a rate of 20 l/h in case of kerosene) which often caused the interruption of fuel feeding because of air collected in the piping could not be sufficiently exhausted. the head loss of this flow meter (NDR-6W), meanwhile, is so small as only 25 mmAq at the rate 20 l/h in the same case. This characteristic performance raises to a maximum the exhaust effect and reduces to a minimum the interruption of fuel feeding. Dust does not effect: In the piston type flow meters, dust tends to impede the motion of piston being collected in the gap scarcely left between the piston and the cylinder and besides at a piston ring in use, so that strainer is indispensable to check the entrance of dust. The NDR-6W and separate inner-mechanism, however, no strainer is generally required because the dust is to settle down outside the diaphragm sections so as not to affect the measuring mechanism. Water does not affect (in case of fuel measuring): In the piston type flow meters, the water may rust the piston or freeze in winter, but the NDR-6W separate inner-mechanism the water never affects the measuring mechanism even if it is frozen because it is collected outside the diaphragm sections and later it is discharged through the drain hole. If it should happen the meter filled with water by mistake, the meter must be dismantled from the line and turned upside down so the water will be drained from all parts of the meter. 4. Kinds of fluid to be measured The DR-6 is actual production is designed for measuring kerosene but it is also available for light or heavy oil, machine oil, spindle oil and engine oil etc. Alcohol, ethylene glycol and others, in addition can also be applied by changing the material of some parts, so that any reference is willing to be received in company with data on the kind of fluid required, the oiliness and the working temperature, and etc. 5. Characteristics of registration accuracy Owing the special design of this meter for extra small flow, the speed of revolving part is extremely slow paste, that is measuring mechanism makes 50 revolutions per hour at a rate of 20 l/h which is equivalent to only 0.8 revolution per minute. Accordingly, the force necessary to overcome the fluid resistance and diaphragm distortion resistance, namely, the difference between the pressures to be applied upon both sides of diaphragm is very small, and so the registration accuracy will hardly be affected even by the change of fluid resistance which depends on the kind of fluid. The oiliness of the fluid to be measured, however, will somewhat affect mechanical resistance. In case of the fluid of lower oiliness such as water, the registration will be a bit less than the practical value by certain increase of mechanical resistance. On the other hand, in case of the fluid of higher oiliness such as machine oil and the engine oil, the registration accuracy will hardly be affected in comparison with case of kerosene, though the mechanical resistance will slightly decrease. Meanwhile, the mechanical resistance so small as under 20 mmAq enables oil layer to remain at all times between the valve and the valve seat, which prevents and leakage from the gap and consequently the registration accuracy maintained stable unlike the other flow meters so as not to be affected by change of gap flow which depends on the kind of oil. 6. Accuracy and minimum flow Accuracy: Plus of minus 1% of actual flow within specified range. Minimum flow: The minimum flow is 5 liters, that is accuracy of ±1% will be kept up when the flow more than 5 liters measured. It shall be taken into account that the accurate value will be lost in case of the flow less than 5 liters. 7. Fluctuation by temperature the fluctuation of the instrumental error and head loss to be caused by the variation of temperature between +20°C and -20°C shall not exceed 1.0% and 10 mmAq respectively. 8. Loss of head The loss of head for some fluid is listed below. Fluid Viscosity Maximum flow rate (liters/h) Head loss max. flow rate (mmAq) Water 1 20 45 Gasoline 0.7 20 40 Kerosene 1.1 20 55 Heavy Oil 10 15 75 Engine Oil 321 10 130 9. Working flow range The determination of working flow range for each kind of oil depends on the permissible head loss and flatness of instrumental performance curve. The date on kerosene indicates that the accuracy in working of ±1% is adaptive up to 50 l/h in view of the flatness of instrumental performance curve. Also for the fluid more viscosity, the metering accuracy of ±1% will be adaptive up to 50 l/h, if whole feeding system is not affected by increase of head loss. In case of minimum flow, meanwhile, no internal leakage will be caused and so it is possible to measure as low as 0.1 l/h. 10. Effect of electromagnetic valve The oil feeding to a boiler will be controlled quickly by the opening or closing of electromagnetic valve, which effects on the instrumental error come out s follows: No difference of instrumental error is recognized between the non operational of electromagnetic valve and continuous operation of the same intervals of around two seconds. No difference of instrumental error is recognized between before the operation of electromagnetic valve and after its operation of 300,000 cycles. 11. Durability The oil had been experimentally passed through the meter at the rate of 20 l/h every day over two years which total flow reached more than 20 kl. And every month during its term the registration accuracy had been checked at the rate of 0.5 l/h, 5 l/h, and 20 l/h respectively and its results demonstrated the accuracy within ±1% in all cases. 12. Connection Connection: 8mm (15A gas pipe or 8mm copper pipe), Adaptors accept 1/8" male NPT fitting Standard specifications Flow Range: 0.1L/h - 20L/h Maximum working pressure: 0.1MPa (1.0kgf/cm²) (1 atm) Maximum working temperature: 45°C Accuracy: Within ±±1.5% (4L/h to 20L/h) Maximum registration: 99999.99 liter Minimum Registration: 0.00% L Minimum scale: 0.02 liter Weight: 1.3 kg Inlet: Left Inside diameter: 8 mm Connection: 8mm (15A gas pipe or 8mm copper pipe), Adaptors accept 1/8" male NPT fitting Measuring flow range C:/Documents and Settings/Mehmet/My Documents/kimmonquartzeskihali/htdocs/Pages/FlowTotalizer.htm 6/8 9/6/12 Flow Totalizer Fluid Viscosity Flow range (liters/h) Water 1 0.1 ~ 20 Gasoline 0.7 0.1 ~ 20 Kerosene 1.1 0.1 ~ 20 Heavy Oil 10 0.1 ~ 15 Engine Oil 321 0.1 ~ 10 Corrosion Product Samplers Corrosion Product Sampling Product Description Applications Features Model 200-BC2 Corrosion Product Sampling In addition to the impact of corrosion on the performance and reliability of power cycle components such as feedwater heaters and condensers, release of corrosion products from such components and their deposition in turbines and steam generating equipment frequently has led to losses of power generating capability at fossil and nuclear power plants. Since grab sampling and analysis approaches generally will not yield accurate concentration data because of the nature of the corrosion product transport process, application of integrating sampling techniques is mandatory if corrosion product transport and deposition rates are to be quantified (NP-5056-SR). Product Description Single and dual channel corrosion product samplers, each available with or without sample coolers. Additionally, all samplers include bypass flow capability. This configuration, as illustrated in Figure 1, provides the ability to process a sample from any point in the cycle while maintaining a high sample line Reynolds number via the bypass system. A 0.45 mm filter is generally used to collect filterable species from a continuous sample flow with a cation ion exchange membrane inserted below the filter to collect soluble cationic species and possibly colloidal species passing through the 0.45 mm filter. With a sample flow of 100 ml/min for 24 hours, the membrane packet accumulates the impurities present in a 144-liter sample. Pressure regulation is provided to maintain a constant sample flow as the pressure drop across the membranes increases with time. The flow Totalizer furnishes an accurate value for the total sample volume of the period. Applications As stated in the PWR Secondary Water Chemistry Guidelines (EPRI NP-5056-SR): “This sample collection method allows long-term averaging of corrosion product concentrations thereby providing a firm basis for performing mass balances around specific components, e.g., it is possible to identify major sources of corrosion products within the feedwater system.” Features High bypass flow capability (up to 2.2 liters/min.). Pressure regulation downstream of the filter holder to maintain constant sample flow. As a result, constant sample flow is assured as the differential pressure across the filter membranes increases with time. Sample flow totalizing (mechanical with ±3.0% accuracy). Samplers provided in cabinets with clearly illustrated flow schematic on panel. C:/Documents and Settings/Mehmet/My Documents/kimmonquartzeskihali/htdocs/Pages/FlowTotalizer.htm 7/8 9/6/12 Flow Totalizer Sample inlet conditions: up to 3000 psig and 500°F (110°F on samplers without coolers); higher-pressure and temperature capability available on request. Filter holder connections are Cajon® VCO fittings for easy use and long life. Inlet and outlet connections are located on a rear bulkhead panel. Rack-mountable models are available. All fittings and valves are Swagelok® family components. When a sampler is supplied with cooling capability, the cooler(s) are mounted inside the cabinet and connected with stainless steel tubing to 1/2" Swagelok® bulkhead fittings on a rear panel ready for connection to the cooling water supply. Samplers do not require electrical power. This eliminates the need to install an electrical supply or to be concerned with battery replacement. Sampler can be easily connected to analyzers downstream. A high temperature, high-pressure inlet isolation valve is provided on the panel. Hence, other than the process root valve, no other isolation valves are needed. This conforms to recommended corrosion product sampling practice, e.g. minimize the number of valves between the process stream and the filter housing. All valves, regulators and fittings are stainless steel (Type 316). All tubing is seamless SA-213 Type 304 stainless steel. Filter inlet isolation is accomplished with a 1/4 turn Whitey® Series 33 ball valve. Samplers are mounted in painted steel cabinets with side handholds. Approximate cabinet sizes and weights for the current models are as follows: 100 Series: 10-7/8”W x 15-3/4”H x 14-1/2”D; 51 lbs with cooler; 35 lbs without cooler 200 Series: 20-3/8”W x 15-3/4”H x 14-1/2”D; 100 lbs with coolers; 68 lbs without coolers C:/Documents and Settings/Mehmet/My Documents/kimmonquartzeskihali/htdocs/Pages/FlowTotalizer.htm 8/8
Frequently asked questions
What makes Elite.Parts unique?

What kind of warranty will the NDR-6W have?

Which carriers does Elite.Parts work with?

Will Elite.Parts sell to me even though I live outside the USA?

I have a preferred payment method. Will Elite.Parts accept it?

What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods