Elite.Parts chervon right Manufacturers chervon right K chervon right KEPCO chervon right HSF 3.3-70
About product Datasheet FAQ

KEPCO HSF 3.3-70

Image of KEPCO HSF 3.3-70

Description

350 Watt Hot Swappable Power Supply

Part Number

HSF 3.3-70

Price

Request Quote

Manufacturer

KEPCO

Lead Time

Request Quote

Category

PRODUCTS - H

Datasheet

pdf file

HSF 12-30-1.pdf

249 KiB

Extracted Text

PLEASE FILL IN THIS CARD TO RECEIVE MORE INFO 146-1869 FAST ON KEPCO HSF/HSP POWER SUPPLIES. ACCESSORY HOUSINGS MAIL OR FAX TO NEAREST ADDRESS. 146-1869 FOR HSP MODELS I need the following YOU NEED QUOTE ME models, and quantities. RA 60 KEPCO’S PLUG-IN My application is: CALL ME Tool-activated locking devices mount HSP modules HOT SWAPS RA 60 19˝ Rack (3) HSP Modules 3 slots wired in parallel for redundancy a free demo. I WANT hot swap connectors WHEN... RA 60 front view (top), RA 60 rear view (bottom) RA 62 SEND ME 19˝ Rack (3) HSP Modules ...YOUR EQUIPMENT BAY IS SHORT ON SPACE. Kepco’s Full-line Catalog on Instrumentation 2 slots wired in parallel, and Modular Power Supplies for System, 1 independent Give us 3U x 19˝ and get: Bench and the OEM, #146-1862 OUTLINE DIMENSIONAL DRAWINGS FOR HSP PLUG-IN MODULES hot swap connectors Fractional dimensions in light face type are in inches. dimensions in bold face type are in millimeters. (3) 1000W plug-in power supplies or (6) 150W plug-ins or (8) 100W plug-ins or Tolerance: ± 1/64" (0.4) between mounting holes RA 63 Name M/S Title ± 1/32" (0.8) other dimensions (First) (Last) 19˝ Rack (3) HSP Modules (8) 50W plug-ins or mix the 50, 100 and 150W modules in the rack. independent slots Company Dept. hot swap connectors Address RA 58 City State Zip ...YOU HAVE TO STAY ON-LINE, NO MATTER WHAT. 19˝ Rack (3) HSP Modules Phone ( ) Fax No. ( ) independent slots, hardwire Kepco’s plug-in, fault tolerant, hot swap power supplies current share FRONT VIEW TOP VIEW and have built-in or-ing diodes for real N+1 redundancy. To configure the above rack PLEASE FILL IN THIS CARD TO RECEIVE MORE INFO housings for 23˝ or 24˝ wide FAST ON KEPCO HSF/HSP POWER SUPPLIES. rack cabinets, add suffix -23E MAIL OR FAX TO NEAREST ADDRESS. 146-1869 or -24E respectively ...YOU NEED TO MIX ‘N MATCH. RA 59 I need the following QUOTE ME models, and quantities. 24˝ Rack (4) HSP Modules Kepco’s hot swap power supplies range from 3.3~48V; 4 slots wired in parallel 50, 100, 150 and 1000 watts per module; up to 3000W per 3U rack. hot swap connectors RA 61 REAR VIEW 24˝ Rack (4) HSP Modules SIDE VIEW My application is: CALL ME independent slots, hardwire RA 59 HSP ACCESSORIES 118-0776 line cord set with NEMA 5-20P termination (125V/20A) a free demo. I WANT 142-0381 source power entry mating connector 142-0422 I/O mating connector SEND ME Tool-activated 108-0203 I/O connector jackposts (set of two) Series HSF 50-150W plug-in modules for Series HSP 1000W plug-in modules for Kepco’s Full-line Catalog on Instrumentation locking devices mount HSP modules and Modular Power Supplies for System, multi output or N+1 redundancy multi output or N+1 redundancy 108-0296 I/O connector shell Bench and the OEM, #146-1862 101-0159 screw for mounting plastic feet LOOK INSIDE FOR PROBLEM SOLVING DETAILS Name M/S Title AN ISO 9001 COMPANY (First) (Last) Company Dept. AN ISO 9001 COMPANY Address City State Zip KEPCO, INC. • 131-38 SANFORD AVENUE • FLUSHING, NY 11352 USA • (718) 461-7000 • FAX: (718) 767-1102 8 E-MAIL: hq@kepcopower.com • URL: http://www.kepcopower.com Phone ( ) Fax No. ( ) ❑❑❑❑❑❑❑❑ Use The Reverse Side To Tell Us Your Needs SERIES HSF HSF MODEL TABLE HSP SIGNALS AND FLAGS The Kepco HSF series of hot- Enclose in an envelope and mail or fax to: OUTPUT SPECIFICATIONS RATING/DESCRIPTION CONDITION swappable plug-in power OVP CURRENT CURRENT SW RIPPLE NOISE REGIONAL OFFICES OUTPUT ADJUSTMENT SETTING AMPS LIMIT mV (spike) Status Flags supplies are designed to be POWER Indicates low source MODEL VOLTS RANGE (VOLTS) 0-50°C (AMPS) typ max mV max voltage signal asserted (Form C dry combined in an N+1 fault-tol- HEADQUARTERS / EASTERN REGION: KEPCO, INC. 50 WATT MODELS 5 msec prior to loss relay contacts) 131-38 Sanford Avenue, Flushing, NY 11352 USA erant power system. Built-in of output voltage Tel: (718) 461-7000 • Fax: (718) 767-1102 HSF 5-10 5 4.5-5.5 7.0~8.0 0-10.0 10.5~12.0 30 60 <120 forced current sharing and E-Mail: hq@kepcopower.com • URL: http://www.kepcopower.com OUTPUT Indicates normal HSF 12-4.2 12 11.4-12.6 13.7~15.7 0-4.2 4.4~5.1 35 70 <190 Both NO and NC or-ing diodes are provided WESTERN REGION: KEPCO, INC. operation available for this purpose. HSF may HSF 15-3.4 15 13.5-16.5 17.0~19.0 0-3.4 3.6~4.1 45 90 <220 800 West Airport Freeway, Suite 320 LB 6018 OVER TEMP Over temperature Irving, TX 75062 USA • Tel: (972) 579-7746 also be used independently HSF 24-2.1 24 22.5-25.5 27.0~30.5 0-2.1 2.2~2.6 50 100 <310 shutdown Fax: (972) 579-4608 • E-Mail: kepcotx@aol.com as a multi-output power HSF 48-1 48 45.0-51.0 53.5~60.0 0-1 1.1~1.3 60 150 <350 FAN FAIL Failure of internal fan supply. 100 WATT MODELS DIRECT SALES OFFICE Lit when a-c HSF are designed as plug-ins to Rear View of the HSP plug-in module Status Indicators POWER Green HSF 5-20 5 4.5-5.5 7.0~8.0 0-20 21.0~24.0 30 65 <120 KEPCO, INC., PENNSYLVANIA is sufficient a Kepco series RA 19-(X)B rack. front panel LEDs HSF 12-8.3 12 11.4-12.6 13.7~15.7 0-8.3 8.7~10.0 35 70 <190 336 Bala Terrace West, West Chester, PA 19380 Lit when output The RA 19-6B will accommodate DC FAIL Red Tel: (610) 594-0856 • Fax: (610) 594-8023 Status indicators HSF 15-6.6 15 13.5-16.5 17.0~19.0 0-6.6 7.0~8.0 40 80 <220 failure is detected six 150W plug-in modules. The E-Mail: powerman@netreach.net and status flags are Lit when thermostat HSF 24-4.2 24 22.5-25.5 27.0~30.5 0-4.2 4.4~5.2 50 110 <310 RA 19-8B will accommodate OVER TEMP Yellow isolated and operate activates SALES REPRESENTATIVES eight 50W or 100W plug-in mod- independently al- HSF 28-3.5 28 26.5-29.5 32.0~35.0 0-3.5 3.7~4.2 60 140 <330 though driven by the Lit when fan failure ules. The RA 19-7B will accom- FAN FAIL Red HSF 48-2 48 45.0-51.0 53.5~60.0 0-2 2.1~2.4 80 220 <530 same detector circuit HARRY LEVINSON COMPANY Seattle, Washington (Main Office) is detected modate three 150W and four Tel: (206) 382-1300 • Fax: (206) 382-0186 150 WATT MODELS 50W or 100W plug-in modules. It E-Mail: hickam@aol.com Also covers Canada West (BC) HSF 5-30 5 4.5-5.5 7.0~8.0 0-30 32.0~36.0 30 60 <120 will also accommodate four HSP CURRENT HARMONICS, SOURCE N-S WESTRONICS - Sunnyvale, California 150W and three 50W or 100W HSF 12-12 12 11.4-12.6 13.7~15.7 0-12 13.0~15.0 35 70 <190 Tel: (408) 745-1102 • Fax: (408) 745-1106 TRANSIENTS AND EMI SPECIFICATIONS plug-in modules. E-Mail: nsw@pacbell.net HSF 15-10 15 13.5-16.5 17.0~19.0 0-10 11.0~13.0 40 80 <220 SYNERTEK MARKETING - Arcadia, California DOCUMENT SPECIFICATION PARAMETER The front panel of each plug-in HSF 24-6 24 22.5-25.5 27.0~30.5 0-6 6.3~7.5 50 110 <310 Tel: (818) 357-0371 • Fax: (818) 303-5796 (1) HSFmodule contains an on-off E-Mail: main@synertekmkt.com HSF 28-5 28 26.5-29.5 32.0~35.0 0-5 5.3~6.1 60 140 <330 IMMUNITY switch and a “V d-c on” light. EARLE ASSOCIATES INC. - San Diego, California HSF 48-2.8 48 45.0-51.0 53.5~60.0 0-2.8 3.0~3.5 80 220 <530 Radiated RF EN 61000-4-3 10V/m, 80-1000MHz When HSF modules are paral- Tel: (619) 278-5441 • Fax: (619) 278-5443 (Ampl. mod.) leled, the module with the highest E-Mail: earle.associates.distrib@symbios.com (1) Current limit is a rectangular type, not foldback. voltage setting automatically AZTEC ENTERPRISES, INC. Denver, Colorado (Main Office) Radiated RF EN 61000-4-3 10V/m, 900MHz Tel: (303) 779-5285 • Fax: (303) 779-5334 becomes the “master” (indicated (Pulse mod.) Rear view, cover removed, of the E-Mail: 105050.3447@compuserve.com by the front panel “master on” HSF GENERAL SPECIFICATIONS rack housing showing the heavy-duty Magnetic Field EN 61000-4-8 30A/M, 50Hz light). The other units are slaves, bus-bar connections that make BASE EIGHT, INC. - Bloomington, Minnesota (Western Region) track the voltage setting of the SPECIFICATION RATING/DESCRIPTION CONDITION Electrostatic 4KV (contact) EN 61000-4-2 HSP’s “Hot Swap” practical. Tel: (612) 941-5888 • Fax: (612) 941-5757 master and equally share the Temperature 0° to 71°C Operating Discharge 8KV (air) Note: The a-c input connector E-Mail: rhoran@base8.com load current. The front panel volt- (see figure 1) is supplied with a BASE EIGHT, INC. - Arlington Heights, Illinois (Eastern Region) Conducted RFI 10Vrms, 0.15-80MHz age adjustment trimmer provides EN 61000-4-6 -40°C to +85°C Storage mating connector, too. (Main Office) Tel: (847) 670-1680 • Fax: (847) 670-1737 adjustment of the output voltage. Electrical Fast EN 61000-4-4 2KV, Tr/Th = 5/50ns E-Mail: 75117.3565@compuserve.com Humidity Up to 95% RH Non-condensing A pair of test points provide Transient Operating & storage TECREP CORPORATION - Hazelwood, Missouri access at the front panel to mea- Tel: (630) 627-9110 • Fax: (630) 627-9129 Shock 20g, 3 axes (11msec Non-operating 4KV (CM) Tr/Th = 8/20µs Surge (CM, DM) EN 61000-4-5 sure the voltage. E-Mail: tccrk@aol.com ±5msec pulse duration) 3 shocks each axis 2KV (DM) Tr/Th = 8/20µs DATA MARKETING ASSOC. INC. Dallas, Texas (Main Office) Vibration 5-10Hz: 10mm amplitude 3 axes Non-operating EMISSIONS Tel: (972) 661-0300 • Fax: (972) 490-0836 1 hour each axis 10-55Hz: 2g, 3 axes 0.45-30MHz E-Mail: dma@cyberramp.net Conducted RF FCC Class A CISPR 22, Class A 0.15-30MHz Isolation Output-Case 500V d-c, 100M Ohm 25°C, 65% RH STAR ENGINEERING SALES CORP. - Milwaukee, Wisconsin Tel: (414) 645-3680 • Fax: (414) 383-1301 Type of construction Plug-in Current 0-2KHz EN 60555-2 and E-Mail: starengs@exepc.com Harmonics EN 61000-3-2 Cooling Convection EQS SYSTEMS Chesterland, Ohio (Main Office) (1) All immunity levels meet the requirements for heavy industrial applications per Withstand Input-Output 3.75KV a-c for 1 minute 25°C, 65% RH Tel: (216) 729-2222 • Fax: (216) 729-2257 EN 50082-2 using Criteria A (no operational effect). voltage Y caps removed E-Mail: sales@eqssystems.com Input-Case 2KV a-c for 1 minute 50W FIGURE 1: W.A. BROWN INSTRUMENTS INC. Orlando, Florida (Main Office) OUTPUT POWER RATING HSP PHYSICAL CHARACTERISTICS Tel: (407) 648-9660 • Fax: (407) 839-0337 Withstand Input-Output 3KV a-c for 1 minute 25°C, 65% RH VS. AMBIENT TEMPERATURE E-Mail: jtconnell@aol.com voltage Y caps removed Input-Case 2KV a-c for 1 minute SPECIFICATI0NS RATING/DESCRIPTION CONDITION 100W,150W EASTERN INSTRUMENTATION CORP. - Washington, D.C. Dimensions English 5.38" x 5.22" x 16" Excluding front latch, Tel: (301) 384-8500 • Fax: (301) 421-1730 Safety UL 1950; EN 60950; circuit breaker, handle E-Mail: gene@eicorp.com Metric 137 x 133 x 406 mm CSA 22.2 No. 950-95 and rear connections Series HSM RAY PERRON & CO., INC. Boston, Massachusetts (Main Office) Modular version for Tel: (617) 449-6162 • Fax: (617) 444-1074 Weight English 19lbs hard wired applications E-Mail: sales@rpc-inc.com Metric 8.6Kg NORTHERN TECHNICAL SALES - Pittsford, New York HSF are CE marked per the Low Voltage For applications that do not Source connection 3 pin IEC connector Compatible with Tel: (716) 385-6480 • Fax: (716) 385-7546 Directive (LVD), EN60950 require hot-swap plug-in capabil- molded line cord E-Mail: ntsoffice@aol.com ities, see Kepco Series HSM Load connection Two bus bars Keyed for CONTECH INSTRUMENTATION INC. power modules. They bolt to 1.25" x 0.125" x 2.5" plug-in housing Northern NJ, NY metro, Westchester, Rockland your chassis and provide a sta- Tel: (908) 744-2500 • Fax: (908) 744-2505 Signal connection 37 Pin D-subminiature E-Mail: contech@soho.ios.com ble 1000W output. connector Data subject to change without notice. ©1997 KEPCO, INC. Litho in USA MULTITEST ELECTRONICS INC. - CANADA, EAST KEPCO, INC. • 131-38 SANFORD AVENUE • FLUSHING, NY 11352 USA • (718) 461-7000 • FAX: (718) 767-1102 Scarborough, Ontario (Main Office) KEPCO, INC. • 131-38 SANFORD AVENUE • FLUSHING, NY 11352 USA • (718) 461-7000 • FAX: (718) 767-1102 Tel: (416) 609-8396 • Fax: (416) 609-8399 2 E-MAIL: hq@kepcopower.com • URL: http://www.kepcopower.com 7 E-MAIL: hq@kepcopower.com • URL: http://www.kepcopower.com NYM-01 NYM-01 FEATURES FEATURES HSF INPUT CHARACTERISTICS HSP OUTPUT CHARACTERISTICS • Remote sensing. • Built-in EMI Ţlter: Attenuates the conducted noise below the SPECIFICATI0NS RATING/DESCRIPTION CONDITION SPECIFICATION RATING CONDITION • Control/programming of voltage, requirements of both FCC and Output setting range -30% to +10% Of nominal output current, current limit and OVP. a-c nom 120-240V a-c VDE 0871 for Class B comput- Single phase -30% to +25% 48V Models only Voltage • Current walk in control. ing devices. range 95-264V a-c Source effect typ 0.05% Nomimal ± 15% (1) d-c Voltage range 125-370V d-c Polarity insensitive • Safety agency approvals: UL • Remote error sensing: All HSF max 0.1% 1950, CSA 22.2 no. 234, TÜV provide separate remote error Brown-out min 85V a-c/110V d-c Ripple, source and Load effect typ 0.05% 5%-100% load EN 60950. sense terminals: 0.25V voltage load effect increase operation between max 0.1% 0-5% load results in drop/wire. Frequency nom 50-60Hz • HSP meet ANSI C62.41/EN Single phase increased ripple and (2) 61000-4-5 guidelines for with- • Forced current share: Used to range 47-440Hz degraded transient standing surges on the mains. response configure an N+1 system. When EMI FCC and VDE 0871 Conducted Class B the current share bus of paral- Temperature typ 0.01% Per degree C • HSP are ~ 5" x 5" crossection Soft-start circuit Thermistor or thyristor limiter leled HSF are connected togeth- effect (0 to 50°C) plug-ins that mount three max 0.02% Leakage max 0.5mA UL method 120V a-c 50-60Hz er, the load current divides abreast in a standard 5.25" x Combined effect typ 0.15% current equally. If one unit fails, the max 0.75mA VDE method 240V a-c 50-60Hz 19" rack adapter. Output voltage (source, load max 0.3% remaining units will divide the Startup max 50W<500ms From turn on until d-c temperature & time) settings and current limit can be load equally among themselves time 100 &150W<200ms output reaches nominal pre-set so an HSP can be Time effect typ 0.05% 0.5-8.5 hours and continue to supply uninter- Holdup typ 20msec 120V a-c plugged in without powering (drift) max 0.1% rupted current to a critical load. time down the system. min 15msec 100V a-c Start up time max 1 second Any source/load The failed unit is isolated by INPUT CURRENT • HSP are fully protected for any Recovery Excursion <3% of Nominal Output 50-100% load built-in or-ing diodes. characteristics (Amperes) 50W 100W 150W overload including a short cir- Recovery 1000W: 100 µsec Return to 1% of setting • Alarm: A built-in relay provides cuit. Normal overload protec- a-c typ1.02.03.0 1500W: 300 µsec 120V a-crms either normally open (close on Current tion is continuous current limit- Ride through min 21.5 Milliseconds From loss of source max 1.2 2.4 3.5 failure) or normally closed (open ing. A switch selectable option to ţag signal on failure) contacts that may be typ 0.5 1.0 1.5 240V a-c rms will latch the power off after 20 Hold-up time min 5 Milliseconds After signal ţag used to provide an external fail- max 0.7 1.6 2.0 seconds to avoid damage to Overshoot turn on +3% max Any source ure indication. load wires. An overvoltage pro- Fuse value 3.0 5.0 6.3 250V type 5x20mm turn off none 5%-100% load tector latches the power off • Plug-in connector: The HSF Initial turn-on surge, 45 45 45 120V a-c rms Error sense 3.3 & 5V 0.25V Voltage allowance whenever the output exceeds a obtain mains power and provide Ţrst half cycle 90 90 90 240V a-c rms per wire All others 0.4V user-set limit. output via a 24 pin connector EfŢciency typ % 76 76 76 Max load, nominal output Series connection 500V Maximum voltage that mates with a corresponding • Remote control of HSP is (output ţoats) off ground connector in the rack adapter. Circuit type Forward Converter provided via one of two isolated Parallel connection Current shares within 5-100% load, Switching typ 120KHz Nominal load TTL-level signals, one normally • Keying: The HSF are keyed (for redundancy) 5% of rated load hot-swappable frequency high and the other normally low. according to their voltage rating. Selective overvoltage Adjustable 100-140% of Latched, reset by cycling An internal 5V supply powers When the corresponding rack shutdown nominal; factory set to 130% source power off (1) Note: Safety agency approvals are valid only for a-c input because of the fuse rating this circuit and provides the aux- adapter key (pin) is installed by a (2) At 440Hz the leakage current exceeds the UL safety speciŢcation Current limiting Constant current mode Optional shutdown mode illiary 5V, 100mA output. This user, only an HSF of the correct Factory set 110% of I max with 20 second delay 0 voltage is available whenever voltage can be inserted into the Remote on/off RC-1 Normally high Isolated form C or TTL source power is applied whether keyed slot. Remote on/off RC-2 Normally low Isolated form C or TTL HSF OUTPUT CHARACTERISTICS or not the main output is inhibit- Over temperature Thermostat, auto re-start With hysteresis • Safety: Designed to meet UL 1950, ed. The main output is normally CSA C22.2 No. 234 (M90) level 3 SPECIFICATION RATING CONDITION ON if no remote logic is applied. and EN 60950 (a-c input only). Source Effect typ 1.0% The main output voltage is 95-132 or 190-264V a-c remotely trimmable by resis- HSP GENERAL SPECIFICATIONS max 2.0% tance. Both the output voltage Load Effect typ 1.0% 10% to 100% load and current limit are adjustable SPECIFICATI0NS RATING/DESCRIPTION CONDITION max 2.0% over the range 20%-100% by a Temperature -20° to +71°C (see model table) Operating Temperature Effect typ 1.0% 0-10V analog voltage. -40° to +85°C Storage Nominal input, rated load max 2.0% 0-40°C Humidity 0 to 95% RH Non condensing operating & storage Combined Effect typ 2.0% Includes source, load Shock 20g 11msec ±50% Non-operating 3-axes and temperature max 4.0% half sine 3 shocks each axis Time Effect (drift) typ 0.1% 0.5-8.5 hr, Vibration 5-10Hz 10 mm double Non operating 1 hour max load, 25°C amplitude each axis max 0.5% 10-55Hz 2g Recovery Step load 50-100%, excursion <±4% Characteristic rise time >50µs Altitude operating Sea level to 10,000 ft recovery 2ms To within 1% storage Sea level to 160,000 ft FAW 100W Model AN ISO 9001 COMPANY Isolation Output-case 500V d-c 25°C, 65%RH For applications that do not Withstand Input-output 3000V a-c rms 25°C, 65%RH require hot-swap plug-in capabili- voltage AN ISO 9001 COMPANY Input-case 1500V a-c rms ties, see Kepco FAW-series Safety UL 1950; VDE EN 60950; Information Technology power modules. They bolt to your CSA 122.2 No. 234-M90 level 5 Equipment chassis and provide a stable 15, Type of construction Enclosed, plug-in style Stand alone or rack KEPCO, INC. • 131-38 SANFORD AVENUE 25, 50, 100 or 150W output. includes status LEDs, circuit mountable into RA 60 FLUSHING, NY 11352 USA breaker, handle,voltage/current Accommodates (718) 461-7000 • FAX: (718) 767-1102 trimmers, monitor test points up to 3 units KEPCO, INC. • 131-38 SANFORD AVENUE • FLUSHING, NY 11352 USA • (718) 461-7000 • FAX: (718) 767-1102 E-MAIL: hq@kepcopower.com Cooling Internal d-c fan Exhaust to rear 6 E-MAIL: hq@kepcopower.com • URL: http://www.kepcopower.com 3 URL: http://www.kepcopower.com ACCESSORIES FOR SERIES HSP 17.55 (445.77) Three The Kepco HSP series com- HSF MODELS HSP prises a group of ten models, models seven 1000 watt power sup- shown in plies with outputs from 3.3 5.218 RA 60 (132.54) volts to 48 volts and three Housing OUTLINE DIMENSIONAL DRAWINGS 1500 watt power supplies Fractional dimensions in light face type with outputs from 24 volts to are in inches. Dimensions in bold face type 48 volts. All models feature are in millimeters. current-sharing for parallel redundant N+1 operation. 14.95 Models with the or-ing diode, (379.65) 19.0 option R, are capable of hot HSP INPUT CHARACTERISTICS (482.5) swapping when plugged into RA 19-(X)B SPECIFICATIONS RATING/DESCRIPTION CONDITION Kepco’s RA 60 series rack adapters. A mechanical key- a-c Voltage nominal 100-250V a-c Single phase 1000W models ing scheme allows the user range 90-277V a-c Wide range to define which power sup- RA 19-(X)B ACCESSORIES a-c Voltage nominal 200-250V a-c Single phase ply will plug into a specified 1500W models range 180-277V a-c Wide range Accessory Part Number Use slot in the housing. Output (1) (1) d-c Voltage 1000W 125-420V d-c Polarity insensitive RFP 19-24 Filler Panel Cover unused voltage and current limit set- 1/24 Rack 1/24 rack slots tings are adjustable from the (1) 1500W 250-420V d-c Polarity insensitive RA 19-6B Rack Adapter with (6) 150W HSF Installed RFP 19-12 panel and may also be Filler Panel Cover unused Brownout 1000W 75V a-c 1/12 Rack 1/12 rack slots remotely adjusted. Voltage 150V a-c 1500W RFP 19-18 Filler Panel Cover unused The 1000 watt HSP have a Source 47-440Hz >63Hz, input leakage 1/8 Rack 1/8 rack slots wide range a-c input (90-277V Frequency current exceeds RFP 19-16 Filler Panel Cover unused tabulated value a-c). The 1500 watt models 1/6 Rack 1/6 rack slots operate from 180-277V a-c Source 120V a-c 1000W: 11.0A rms RFP 19-28 Filler Panel Cover unused Current mains. Both feature an active Typical 240V a-c 1000W: 5.5A rms 2/8 Rack 2/8 rack slots power factor correction (PFC) 1500W: 8.0A rms RFP 19-26 Filler Panel Cover unused front end to suppress harmon- Power Typical 0.99 Any source, 2/6 Rack 2/6 rack slots RA 19-7B Rack Adapter with (4) 100W and (3) 150W HSF Installed Factor ic generation per EN 60555-2 25% to 100% load Minimum 0.96 RFP 19-38 Filler Panel Cover unused and EN 61000-3-2. 3/8 Rack 3/8 rack slots (1) Safety approval is for a-c operation only. RFP 19-48 HSP have optional built-in “or- Filler Panel Cover unused 1/2 Rack 1/2 rack slots ing” diodes for redundancy paralleling and a “hot-swap” HSP are CE marked per the Low capability. These are specified Weights English Metric Voltage Directive (LVD), EN60950 RA 19-(X)B 22 lbs 10Kg by appending the suffix “R” to 50W 4 lbs 1.8Kg the model number. 100W 5 lbs 2.3Kg 150W 5.5 lbs 2.5Kg RA 19-8B Rack Adapter with (8) 100W HSF Installed HSP MODEL TABLE SPECIFICATION OUTPUT VOLTAGE OVP SETTING RATED OUTPUT CURRENT RIPPLE NOISE EFFICIENCY RA 19-8B Rack Adapter Rear Panel Unit Volts Volts Amps mV p-p mV p-p Percent This is the standard rear panel configuration. Other connector options are available. Please consult the factory. Factory Adjustment Factory Source Switching (Spike) 100% Load Condition Set Range Setpoint 50°C 60°C 71°C max max 20MHz Nominal input The I/O Connector functions are 1000 WATT MODELS brought out as follows: HSP 3.3-230 3.3 2.3-3.6 4.29 230 173 105 20 30 100 71 1- Error sense (+S, -S) for each HSP 5-200 5 3.5-5.5 6.5 200 150 95 20 30 100 72 position. HSP 12-84 12 8.4-13.2 15.6 84 63 40 20 40 120 73 2- Output voltage (+V, -V) for HSP 15-66 15 10.5-16.5 19.5 66 49.5 31.4 20 40 150 76 each position to permit wiring for local sense. HSP 24-42 24 16.8-26.4 31.2 42 31.5 20 20 60 240 77 HSP 28-36 28 19.6-30.8 36.4 36 27 17 20 60 280 78 3- Current share bus (one) connection brought out for HSP 48-21 48 33.3-59.2 62.4 21 16 10 20 60 480 80 each pair of modules. (Each 1500 WATT MODELS pair internally connected using HSP 24-60 24 16.8-26.4 31.2 60 45 28.6 20 60 120 77 DIP switches on the backplane). HSP 28-53 28 19.6-30.8 36.4 53 39.8 25.2 20 60 140 78 4- Output status alarm contacts HSP 48-30 48 33.3-59.2 62.4 30 22.5 14.3 20 60 240 80 (Form C) for each position. KEPCO, INC. • 131-38 SANFORD AVENUE • FLUSHING, NY 11352 USA • (718) 461-7000 • FAX: (718) 767-1102 KEPCO, INC. • 131-38 SANFORD AVENUE • FLUSHING, NY 11352 USA • (718) 461-7000 • FAX: (718) 767-1102 4 E-MAIL: hq@kepcopower.com • URL: http://www.kepcopower.com E-MAIL: hq@kepcopower.com • URL: http://www.kepcopower.com 5 ACCESSORIES FOR SERIES HSP 17.55 (445.77) Three The Kepco HSP series com- HSF MODELS HSP prises a group of ten models, models seven 1000 watt power sup- shown in plies with outputs from 3.3 5.218 RA 60 (132.54) volts to 48 volts and three Housing OUTLINE DIMENSIONAL DRAWINGS 1500 watt power supplies Fractional dimensions in light face type with outputs from 24 volts to are in inches. Dimensions in bold face type 48 volts. All models feature are in millimeters. current-sharing for parallel redundant N+1 operation. 14.95 Models with the or-ing diode, (379.65) 19.0 option R, are capable of hot HSP INPUT CHARACTERISTICS (482.5) swapping when plugged into RA 19-(X)B SPECIFICATIONS RATING/DESCRIPTION CONDITION Kepco’s RA 60 series rack adapters. A mechanical key- a-c Voltage nominal 100-250V a-c Single phase 1000W models ing scheme allows the user range 90-277V a-c Wide range to define which power sup- RA 19-(X)B ACCESSORIES a-c Voltage nominal 200-250V a-c Single phase ply will plug into a specified 1500W models range 180-277V a-c Wide range Accessory Part Number Use slot in the housing. Output (1) (1) d-c Voltage 1000W 125-420V d-c Polarity insensitive RFP 19-24 Filler Panel Cover unused voltage and current limit set- 1/24 Rack 1/24 rack slots tings are adjustable from the (1) 1500W 250-420V d-c Polarity insensitive RA 19-6B Rack Adapter with (6) 150W HSF Installed RFP 19-12 panel and may also be Filler Panel Cover unused Brownout 1000W 75V a-c 1/12 Rack 1/12 rack slots remotely adjusted. Voltage 150V a-c 1500W RFP 19-18 Filler Panel Cover unused The 1000 watt HSP have a Source 47-440Hz >63Hz, input leakage 1/8 Rack 1/8 rack slots wide range a-c input (90-277V Frequency current exceeds RFP 19-16 Filler Panel Cover unused tabulated value a-c). The 1500 watt models 1/6 Rack 1/6 rack slots operate from 180-277V a-c Source 120V a-c 1000W: 11.0A rms RFP 19-28 Filler Panel Cover unused Current mains. Both feature an active Typical 240V a-c 1000W: 5.5A rms 2/8 Rack 2/8 rack slots power factor correction (PFC) 1500W: 8.0A rms RFP 19-26 Filler Panel Cover unused front end to suppress harmon- Power Typical 0.99 Any source, 2/6 Rack 2/6 rack slots RA 19-7B Rack Adapter with (4) 100W and (3) 150W HSF Installed Factor ic generation per EN 60555-2 25% to 100% load Minimum 0.96 RFP 19-38 Filler Panel Cover unused and EN 61000-3-2. 3/8 Rack 3/8 rack slots (1) Safety approval is for a-c operation only. RFP 19-48 HSP have optional built-in “or- Filler Panel Cover unused 1/2 Rack 1/2 rack slots ing” diodes for redundancy paralleling and a “hot-swap” HSP are CE marked per the Low capability. These are specified Weights English Metric Voltage Directive (LVD), EN60950 RA 19-(X)B 22 lbs 10Kg by appending the suffix “R” to 50W 4 lbs 1.8Kg the model number. 100W 5 lbs 2.3Kg 150W 5.5 lbs 2.5Kg RA 19-8B Rack Adapter with (8) 100W HSF Installed HSP MODEL TABLE SPECIFICATION OUTPUT VOLTAGE OVP SETTING RATED OUTPUT CURRENT RIPPLE NOISE EFFICIENCY RA 19-8B Rack Adapter Rear Panel Unit Volts Volts Amps mV p-p mV p-p Percent This is the standard rear panel configuration. Other connector options are available. Please consult the factory. Factory Adjustment Factory Source Switching (Spike) 100% Load Condition Set Range Setpoint 50°C 60°C 71°C max max 20MHz Nominal input The I/O Connector functions are 1000 WATT MODELS brought out as follows: HSP 3.3-230 3.3 2.3-3.6 4.29 230 173 105 20 30 100 71 1- Error sense (+S, -S) for each HSP 5-200 5 3.5-5.5 6.5 200 150 95 20 30 100 72 position. HSP 12-84 12 8.4-13.2 15.6 84 63 40 20 40 120 73 2- Output voltage (+V, -V) for HSP 15-66 15 10.5-16.5 19.5 66 49.5 31.4 20 40 150 76 each position to permit wiring for local sense. HSP 24-42 24 16.8-26.4 31.2 42 31.5 20 20 60 240 77 HSP 28-36 28 19.6-30.8 36.4 36 27 17 20 60 280 78 3- Current share bus (one) connection brought out for HSP 48-21 48 33.3-59.2 62.4 21 16 10 20 60 480 80 each pair of modules. (Each 1500 WATT MODELS pair internally connected using HSP 24-60 24 16.8-26.4 31.2 60 45 28.6 20 60 120 77 DIP switches on the backplane). HSP 28-53 28 19.6-30.8 36.4 53 39.8 25.2 20 60 140 78 4- Output status alarm contacts HSP 48-30 48 33.3-59.2 62.4 30 22.5 14.3 20 60 240 80 (Form C) for each position. KEPCO, INC. • 131-38 SANFORD AVENUE • FLUSHING, NY 11352 USA • (718) 461-7000 • FAX: (718) 767-1102 KEPCO, INC. • 131-38 SANFORD AVENUE • FLUSHING, NY 11352 USA • (718) 461-7000 • FAX: (718) 767-1102 4 E-MAIL: hq@kepcopower.com • URL: http://www.kepcopower.com E-MAIL: hq@kepcopower.com • URL: http://www.kepcopower.com 5 FEATURES FEATURES HSF INPUT CHARACTERISTICS HSP OUTPUT CHARACTERISTICS • Remote sensing. • Built-in EMI Ţlter: Attenuates the conducted noise below the SPECIFICATI0NS RATING/DESCRIPTION CONDITION SPECIFICATION RATING CONDITION • Control/programming of voltage, requirements of both FCC and Output setting range -30% to +10% Of nominal output current, current limit and OVP. a-c nom 120-240V a-c VDE 0871 for Class B comput- Single phase -30% to +25% 48V Models only Voltage • Current walk in control. ing devices. range 95-264V a-c Source effect typ 0.05% Nomimal ± 15% (1) d-c Voltage range 125-370V d-c Polarity insensitive • Safety agency approvals: UL • Remote error sensing: All HSF max 0.1% 1950, CSA 22.2 no. 234, TÜV provide separate remote error Brown-out min 85V a-c/110V d-c Ripple, source and Load effect typ 0.05% 5%-100% load EN 60950. sense terminals: 0.25V voltage load effect increase operation between max 0.1% 0-5% load results in drop/wire. Frequency nom 50-60Hz • HSP meet ANSI C62.41/EN Single phase increased ripple and (2) 61000-4-5 guidelines for with- • Forced current share: Used to range 47-440Hz degraded transient standing surges on the mains. response configure an N+1 system. When EMI FCC and VDE 0871 Conducted Class B the current share bus of paral- Temperature typ 0.01% Per degree C • HSP are ~ 5" x 5" crossection Soft-start circuit Thermistor or thyristor limiter leled HSF are connected togeth- effect (0 to 50°C) plug-ins that mount three max 0.02% Leakage max 0.5mA UL method 120V a-c 50-60Hz er, the load current divides abreast in a standard 5.25" x Combined effect typ 0.15% current equally. If one unit fails, the max 0.75mA VDE method 240V a-c 50-60Hz 19" rack adapter. Output voltage (source, load max 0.3% remaining units will divide the Startup max 50W<500ms From turn on until d-c temperature & time) settings and current limit can be load equally among themselves time 100 &150W<200ms output reaches nominal pre-set so an HSP can be Time effect typ 0.05% 0.5-8.5 hours and continue to supply uninter- Holdup typ 20msec 120V a-c plugged in without powering (drift) max 0.1% rupted current to a critical load. time down the system. min 15msec 100V a-c Start up time max 1 second Any source/load The failed unit is isolated by INPUT CURRENT • HSP are fully protected for any Recovery Excursion <3% of Nominal Output 50-100% load built-in or-ing diodes. characteristics (Amperes) 50W 100W 150W overload including a short cir- Recovery 1000W: 100 µsec Return to 1% of setting • Alarm: A built-in relay provides cuit. Normal overload protec- a-c typ1.02.03.0 1500W: 300 µsec 120V a-crms either normally open (close on Current tion is continuous current limit- Ride through min 21.5 Milliseconds From loss of source max 1.2 2.4 3.5 failure) or normally closed (open ing. A switch selectable option to ţag signal on failure) contacts that may be typ 0.5 1.0 1.5 240V a-c rms will latch the power off after 20 Hold-up time min 5 Milliseconds After signal ţag used to provide an external fail- max 0.7 1.6 2.0 seconds to avoid damage to Overshoot turn on +3% max Any source ure indication. load wires. An overvoltage pro- Fuse value 3.0 5.0 6.3 250V type 5x20mm turn off none 5%-100% load tector latches the power off • Plug-in connector: The HSF Initial turn-on surge, 45 45 45 120V a-c rms Error sense 3.3 & 5V 0.25V Voltage allowance whenever the output exceeds a obtain mains power and provide Ţrst half cycle 90 90 90 240V a-c rms per wire All others 0.4V user-set limit. output via a 24 pin connector EfŢciency typ % 76 76 76 Max load, nominal output Series connection 500V Maximum voltage that mates with a corresponding • Remote control of HSP is (output ţoats) off ground connector in the rack adapter. Circuit type Forward Converter provided via one of two isolated Parallel connection Current shares within 5-100% load, Switching typ 120KHz Nominal load TTL-level signals, one normally • Keying: The HSF are keyed (for redundancy) 5% of rated load hot-swappable frequency high and the other normally low. according to their voltage rating. Selective overvoltage Adjustable 100-140% of Latched, reset by cycling An internal 5V supply powers When the corresponding rack shutdown nominal; factory set to 130% source power off (1) Note: Safety agency approvals are valid only for a-c input because of the fuse rating this circuit and provides the aux- adapter key (pin) is installed by a (2) At 440Hz the leakage current exceeds the UL safety speciŢcation Current limiting Constant current mode Optional shutdown mode illiary 5V, 100mA output. This user, only an HSF of the correct Factory set 110% of I max with 20 second delay 0 voltage is available whenever voltage can be inserted into the Remote on/off RC-1 Normally high Isolated form C or TTL source power is applied whether keyed slot. Remote on/off RC-2 Normally low Isolated form C or TTL HSF OUTPUT CHARACTERISTICS or not the main output is inhibit- Over temperature Thermostat, auto re-start With hysteresis • Safety: Designed to meet UL 1950, ed. The main output is normally CSA C22.2 No. 234 (M90) level 3 SPECIFICATION RATING CONDITION ON if no remote logic is applied. and EN 60950 (a-c input only). Source Effect typ 1.0% The main output voltage is 95-132 or 190-264V a-c remotely trimmable by resis- HSP GENERAL SPECIFICATIONS max 2.0% tance. Both the output voltage Load Effect typ 1.0% 10% to 100% load and current limit are adjustable SPECIFICATI0NS RATING/DESCRIPTION CONDITION max 2.0% over the range 20%-100% by a Temperature -20° to +71°C (see model table) Operating Temperature Effect typ 1.0% 0-10V analog voltage. -40° to +85°C Storage Nominal input, rated load max 2.0% 0-40°C Humidity 0 to 95% RH Non condensing operating & storage Combined Effect typ 2.0% Includes source, load Shock 20g 11msec ±50% Non-operating 3-axes and temperature max 4.0% half sine 3 shocks each axis Time Effect (drift) typ 0.1% 0.5-8.5 hr, Vibration 5-10Hz 10 mm double Non operating 1 hour max load, 25°C amplitude each axis max 0.5% 10-55Hz 2g Recovery Step load 50-100%, excursion <±4% Characteristic rise time >50µs Altitude operating Sea level to 10,000 ft recovery 2ms To within 1% storage Sea level to 160,000 ft FAW 100W Model AN ISO 9001 COMPANY Isolation Output-case 500V d-c 25°C, 65%RH For applications that do not Withstand Input-output 3000V a-c rms 25°C, 65%RH require hot-swap plug-in capabili- voltage AN ISO 9001 COMPANY Input-case 1500V a-c rms ties, see Kepco FAW-series Safety UL 1950; VDE EN 60950; Information Technology power modules. They bolt to your CSA 122.2 No. 234-M90 level 5 Equipment chassis and provide a stable 15, Type of construction Enclosed, plug-in style Stand alone or rack KEPCO, INC. • 131-38 SANFORD AVENUE 25, 50, 100 or 150W output. includes status LEDs, circuit mountable into RA 60 FLUSHING, NY 11352 USA breaker, handle,voltage/current Accommodates (718) 461-7000 • FAX: (718) 767-1102 trimmers, monitor test points up to 3 units KEPCO, INC. • 131-38 SANFORD AVENUE • FLUSHING, NY 11352 USA • (718) 461-7000 • FAX: (718) 767-1102 E-MAIL: hq@kepcopower.com Cooling Internal d-c fan Exhaust to rear 6 E-MAIL: hq@kepcopower.com • URL: http://www.kepcopower.com 3 URL: http://www.kepcopower.com Use The Reverse Side To Tell Us Your Needs SERIES HSF HSF MODEL TABLE HSP SIGNALS AND FLAGS The Kepco HSF series of hot- Enclose in an envelope and mail or fax to: OUTPUT SPECIFICATIONS RATING/DESCRIPTION CONDITION swappable plug-in power OVP CURRENT CURRENT SW RIPPLE NOISE REGIONAL OFFICES OUTPUT ADJUSTMENT SETTING AMPS LIMIT mV (spike) Status Flags supplies are designed to be POWER Indicates low source MODEL VOLTS RANGE (VOLTS) 0-50°C (AMPS) typ max mV max voltage signal asserted (Form C dry combined in an N+1 fault-tol- HEADQUARTERS / EASTERN REGION: KEPCO, INC. 50 WATT MODELS 5 msec prior to loss relay contacts) 131-38 Sanford Avenue, Flushing, NY 11352 USA erant power system. Built-in of output voltage Tel: (718) 461-7000 • Fax: (718) 767-1102 HSF 5-10 5 4.5-5.5 7.0~8.0 0-10.0 10.5~12.0 30 60 <120 forced current sharing and E-Mail: hq@kepcopower.com • URL: http://www.kepcopower.com OUTPUT Indicates normal HSF 12-4.2 12 11.4-12.6 13.7~15.7 0-4.2 4.4~5.1 35 70 <190 Both NO and NC or-ing diodes are provided WESTERN REGION: KEPCO, INC. operation available for this purpose. HSF may HSF 15-3.4 15 13.5-16.5 17.0~19.0 0-3.4 3.6~4.1 45 90 <220 800 West Airport Freeway, Suite 320 LB 6018 OVER TEMP Over temperature Irving, TX 75062 USA • Tel: (972) 579-7746 also be used independently HSF 24-2.1 24 22.5-25.5 27.0~30.5 0-2.1 2.2~2.6 50 100 <310 shutdown Fax: (972) 579-4608 • E-Mail: kepcotx@aol.com as a multi-output power HSF 48-1 48 45.0-51.0 53.5~60.0 0-1 1.1~1.3 60 150 <350 FAN FAIL Failure of internal fan supply. 100 WATT MODELS DIRECT SALES OFFICE Lit when a-c HSF are designed as plug-ins to Rear View of the HSP plug-in module Status Indicators POWER Green HSF 5-20 5 4.5-5.5 7.0~8.0 0-20 21.0~24.0 30 65 <120 KEPCO, INC., PENNSYLVANIA is sufficient a Kepco series RA 19-(X)B rack. front panel LEDs HSF 12-8.3 12 11.4-12.6 13.7~15.7 0-8.3 8.7~10.0 35 70 <190 336 Bala Terrace West, West Chester, PA 19380 Lit when output The RA 19-6B will accommodate DC FAIL Red Tel: (610) 594-0856 • Fax: (610) 594-8023 Status indicators HSF 15-6.6 15 13.5-16.5 17.0~19.0 0-6.6 7.0~8.0 40 80 <220 failure is detected six 150W plug-in modules. The E-Mail: powerman@netreach.net and status flags are Lit when thermostat HSF 24-4.2 24 22.5-25.5 27.0~30.5 0-4.2 4.4~5.2 50 110 <310 RA 19-8B will accommodate OVER TEMP Yellow isolated and operate activates SALES REPRESENTATIVES eight 50W or 100W plug-in mod- independently al- HSF 28-3.5 28 26.5-29.5 32.0~35.0 0-3.5 3.7~4.2 60 140 <330 though driven by the Lit when fan failure ules. The RA 19-7B will accom- FAN FAIL Red HSF 48-2 48 45.0-51.0 53.5~60.0 0-2 2.1~2.4 80 220 <530 same detector circuit HARRY LEVINSON COMPANY Seattle, Washington (Main Office) is detected modate three 150W and four Tel: (206) 382-1300 • Fax: (206) 382-0186 150 WATT MODELS 50W or 100W plug-in modules. It E-Mail: hickam@aol.com Also covers Canada West (BC) HSF 5-30 5 4.5-5.5 7.0~8.0 0-30 32.0~36.0 30 60 <120 will also accommodate four HSP CURRENT HARMONICS, SOURCE N-S WESTRONICS - Sunnyvale, California 150W and three 50W or 100W HSF 12-12 12 11.4-12.6 13.7~15.7 0-12 13.0~15.0 35 70 <190 Tel: (408) 745-1102 • Fax: (408) 745-1106 TRANSIENTS AND EMI SPECIFICATIONS plug-in modules. E-Mail: nsw@pacbell.net HSF 15-10 15 13.5-16.5 17.0~19.0 0-10 11.0~13.0 40 80 <220 SYNERTEK MARKETING - Arcadia, California DOCUMENT SPECIFICATION PARAMETER The front panel of each plug-in HSF 24-6 24 22.5-25.5 27.0~30.5 0-6 6.3~7.5 50 110 <310 Tel: (818) 357-0371 • Fax: (818) 303-5796 (1) HSFmodule contains an on-off E-Mail: main@synertekmkt.com HSF 28-5 28 26.5-29.5 32.0~35.0 0-5 5.3~6.1 60 140 <330 IMMUNITY switch and a “V d-c on” light. EARLE ASSOCIATES INC. - San Diego, California HSF 48-2.8 48 45.0-51.0 53.5~60.0 0-2.8 3.0~3.5 80 220 <530 Radiated RF EN 61000-4-3 10V/m, 80-1000MHz When HSF modules are paral- Tel: (619) 278-5441 • Fax: (619) 278-5443 (Ampl. mod.) leled, the module with the highest E-Mail: earle.associates.distrib@symbios.com (1) Current limit is a rectangular type, not foldback. voltage setting automatically AZTEC ENTERPRISES, INC. Denver, Colorado (Main Office) Radiated RF EN 61000-4-3 10V/m, 900MHz Tel: (303) 779-5285 • Fax: (303) 779-5334 becomes the “master” (indicated (Pulse mod.) Rear view, cover removed, of the E-Mail: 105050.3447@compuserve.com by the front panel “master on” HSF GENERAL SPECIFICATIONS rack housing showing the heavy-duty Magnetic Field EN 61000-4-8 30A/M, 50Hz light). The other units are slaves, bus-bar connections that make BASE EIGHT, INC. - Bloomington, Minnesota (Western Region) track the voltage setting of the SPECIFICATION RATING/DESCRIPTION CONDITION Electrostatic 4KV (contact) EN 61000-4-2 HSP’s “Hot Swap” practical. Tel: (612) 941-5888 • Fax: (612) 941-5757 master and equally share the Temperature 0° to 71°C Operating Discharge 8KV (air) Note: The a-c input connector E-Mail: rhoran@base8.com load current. The front panel volt- (see figure 1) is supplied with a BASE EIGHT, INC. - Arlington Heights, Illinois (Eastern Region) Conducted RFI 10Vrms, 0.15-80MHz age adjustment trimmer provides EN 61000-4-6 -40°C to +85°C Storage mating connector, too. (Main Office) Tel: (847) 670-1680 • Fax: (847) 670-1737 adjustment of the output voltage. Electrical Fast EN 61000-4-4 2KV, Tr/Th = 5/50ns E-Mail: 75117.3565@compuserve.com Humidity Up to 95% RH Non-condensing A pair of test points provide Transient Operating & storage TECREP CORPORATION - Hazelwood, Missouri access at the front panel to mea- Tel: (630) 627-9110 • Fax: (630) 627-9129 Shock 20g, 3 axes (11msec Non-operating 4KV (CM) Tr/Th = 8/20µs Surge (CM, DM) EN 61000-4-5 sure the voltage. E-Mail: tccrk@aol.com ±5msec pulse duration) 3 shocks each axis 2KV (DM) Tr/Th = 8/20µs DATA MARKETING ASSOC. INC. Dallas, Texas (Main Office) Vibration 5-10Hz: 10mm amplitude 3 axes Non-operating EMISSIONS Tel: (972) 661-0300 • Fax: (972) 490-0836 1 hour each axis 10-55Hz: 2g, 3 axes 0.45-30MHz E-Mail: dma@cyberramp.net Conducted RF FCC Class A CISPR 22, Class A 0.15-30MHz Isolation Output-Case 500V d-c, 100M Ohm 25°C, 65% RH STAR ENGINEERING SALES CORP. - Milwaukee, Wisconsin Tel: (414) 645-3680 • Fax: (414) 383-1301 Type of construction Plug-in Current 0-2KHz EN 60555-2 and E-Mail: starengs@exepc.com Harmonics EN 61000-3-2 Cooling Convection EQS SYSTEMS Chesterland, Ohio (Main Office) (1) All immunity levels meet the requirements for heavy industrial applications per Withstand Input-Output 3.75KV a-c for 1 minute 25°C, 65% RH Tel: (216) 729-2222 • Fax: (216) 729-2257 EN 50082-2 using Criteria A (no operational effect). voltage Y caps removed E-Mail: sales@eqssystems.com Input-Case 2KV a-c for 1 minute 50W FIGURE 1: W.A. BROWN INSTRUMENTS INC. Orlando, Florida (Main Office) OUTPUT POWER RATING HSP PHYSICAL CHARACTERISTICS Tel: (407) 648-9660 • Fax: (407) 839-0337 Withstand Input-Output 3KV a-c for 1 minute 25°C, 65% RH VS. AMBIENT TEMPERATURE E-Mail: jtconnell@aol.com voltage Y caps removed Input-Case 2KV a-c for 1 minute SPECIFICATI0NS RATING/DESCRIPTION CONDITION 100W,150W EASTERN INSTRUMENTATION CORP. - Washington, D.C. Dimensions English 5.38" x 5.22" x 16" Excluding front latch, Tel: (301) 384-8500 • Fax: (301) 421-1730 Safety UL 1950; EN 60950; circuit breaker, handle E-Mail: gene@eicorp.com Metric 137 x 133 x 406 mm CSA 22.2 No. 950-95 and rear connections Series HSM RAY PERRON & CO., INC. Boston, Massachusetts (Main Office) Modular version for Tel: (617) 449-6162 • Fax: (617) 444-1074 Weight English 19lbs hard wired applications E-Mail: sales@rpc-inc.com Metric 8.6Kg NORTHERN TECHNICAL SALES - Pittsford, New York HSF are CE marked per the Low Voltage For applications that do not Source connection 3 pin IEC connector Compatible with Tel: (716) 385-6480 • Fax: (716) 385-7546 Directive (LVD), EN60950 require hot-swap plug-in capabil- molded line cord E-Mail: ntsoffice@aol.com ities, see Kepco Series HSM Load connection Two bus bars Keyed for CONTECH INSTRUMENTATION INC. power modules. They bolt to 1.25" x 0.125" x 2.5" plug-in housing Northern NJ, NY metro, Westchester, Rockland your chassis and provide a sta- Tel: (908) 744-2500 • Fax: (908) 744-2505 Signal connection 37 Pin D-subminiature E-Mail: contech@soho.ios.com ble 1000W output. connector Data subject to change without notice. ©1997 KEPCO, INC. Litho in USA MULTITEST ELECTRONICS INC. - CANADA, EAST KEPCO, INC. • 131-38 SANFORD AVENUE • FLUSHING, NY 11352 USA • (718) 461-7000 • FAX: (718) 767-1102 Scarborough, Ontario (Main Office) KEPCO, INC. • 131-38 SANFORD AVENUE • FLUSHING, NY 11352 USA • (718) 461-7000 • FAX: (718) 767-1102 Tel: (416) 609-8396 • Fax: (416) 609-8399 2 E-MAIL: hq@kepcopower.com • URL: http://www.kepcopower.com 7 E-MAIL: hq@kepcopower.com • URL: http://www.kepcopower.com NYM-01 NYM-01 PLEASE FILL IN THIS CARD TO RECEIVE MORE INFO 146-1869 FAST ON KEPCO HSF/HSP POWER SUPPLIES. ACCESSORY HOUSINGS MAIL OR FAX TO NEAREST ADDRESS. 146-1869 FOR HSP MODELS I need the following YOU NEED QUOTE ME models, and quantities. RA 60 KEPCO’S PLUG-IN My application is: CALL ME Tool-activated locking devices mount HSP modules HOT SWAPS RA 60 19˝ Rack (3) HSP Modules 3 slots wired in parallel for redundancy a free demo. I WANT hot swap connectors WHEN... RA 60 front view (top), RA 60 rear view (bottom) RA 62 SEND ME 19˝ Rack (3) HSP Modules ...YOUR EQUIPMENT BAY IS SHORT ON SPACE. Kepco’s Full-line Catalog on Instrumentation 2 slots wired in parallel, and Modular Power Supplies for System, 1 independent Give us 3U x 19˝ and get: Bench and the OEM, #146-1862 OUTLINE DIMENSIONAL DRAWINGS FOR HSP PLUG-IN MODULES hot swap connectors Fractional dimensions in light face type are in inches. dimensions in bold face type are in millimeters. (3) 1000W plug-in power supplies or (6) 150W plug-ins or (8) 100W plug-ins or Tolerance: ± 1/64" (0.4) between mounting holes RA 63 Name M/S Title ± 1/32" (0.8) other dimensions (First) (Last) 19˝ Rack (3) HSP Modules (8) 50W plug-ins or mix the 50, 100 and 150W modules in the rack. independent slots Company Dept. hot swap connectors Address RA 58 City State Zip ...YOU HAVE TO STAY ON-LINE, NO MATTER WHAT. 19˝ Rack (3) HSP Modules Phone ( ) Fax No. ( ) independent slots, hardwire Kepco’s plug-in, fault tolerant, hot swap power supplies current share FRONT VIEW TOP VIEW and have built-in or-ing diodes for real N+1 redundancy. To configure the above rack PLEASE FILL IN THIS CARD TO RECEIVE MORE INFO housings for 23˝ or 24˝ wide FAST ON KEPCO HSF/HSP POWER SUPPLIES. rack cabinets, add suffix -23E MAIL OR FAX TO NEAREST ADDRESS. 146-1869 or -24E respectively ...YOU NEED TO MIX ‘N MATCH. RA 59 I need the following QUOTE ME models, and quantities. 24˝ Rack (4) HSP Modules Kepco’s hot swap power supplies range from 3.3~48V; 4 slots wired in parallel 50, 100, 150 and 1000 watts per module; up to 3000W per 3U rack. hot swap connectors RA 61 REAR VIEW 24˝ Rack (4) HSP Modules SIDE VIEW My application is: CALL ME independent slots, hardwire RA 59 HSP ACCESSORIES 118-0776 line cord set with NEMA 5-20P termination (125V/20A) a free demo. I WANT 142-0381 source power entry mating connector 142-0422 I/O mating connector SEND ME Tool-activated 108-0203 I/O connector jackposts (set of two) Series HSF 50-150W plug-in modules for Series HSP 1000W plug-in modules for Kepco’s Full-line Catalog on Instrumentation locking devices mount HSP modules and Modular Power Supplies for System, multi output or N+1 redundancy multi output or N+1 redundancy 108-0296 I/O connector shell Bench and the OEM, #146-1862 101-0159 screw for mounting plastic feet LOOK INSIDE FOR PROBLEM SOLVING DETAILS Name M/S Title AN ISO 9001 COMPANY (First) (Last) Company Dept. AN ISO 9001 COMPANY Address City State Zip KEPCO, INC. • 131-38 SANFORD AVENUE • FLUSHING, NY 11352 USA • (718) 461-7000 • FAX: (718) 767-1102 8 E-MAIL: hq@kepcopower.com • URL: http://www.kepcopower.com Phone ( ) Fax No. ( ) ❑❑❑❑❑❑❑❑

Frequently asked questions

What makes Elite.Parts unique?

chervon down
At GID Industrial (Elite.Parts' parent company), we specialize in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

What kind of warranty will the HSF 3.3-70 have?

chervon down
Warranties differ by part and by which suppliers we use to procure it for you. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carriers does Elite.Parts work with?

chervon down
Elite.Parts can ship via FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Will Elite.Parts sell to me even though I live outside the USA?

chervon down
Absolutely! We are happy to serve customers regardless of location. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

I have a preferred payment method. Will Elite.Parts accept it?

chervon down
All major credit cards are accepted: Visa, MasterCard, Discover, and American Express. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

Kepco HSF 12-12 Adjustment Range 150 Watt Hot Swappable Power Supply

product

350 Watt Hot Swappable Power Supply

product

Kepco HSF 12-4.2 Adjustment Range 11.4-12.6 50 Watt Hot Swappable Power Supply

product

50 Watt Hot Swappable Power Supply

product

Kepco HSF 12-8.3 Adjustment Range 11.4-12.6 100 Watt Hot Swappable Power Supply

product

100 Watt Hot Swappable Power Supply