Elite.Parts chervon right Manufacturers chervon right K chervon right KENTROX chervon right 20001-310
About product Datasheet FAQ

KENTROX 20001-310

Description

CELLSMART 201T ISC DS1 OCTAL IMA TO HSSI 120V AC

Part Number

20001-310

Price

Request Quote

Manufacturer

KENTROX

Lead Time

Request Quote

Category

SPECIALTY PRODUCT

Datasheet

pdf file

05-06-018-1_AAC-CellSMART.pdf

1205 KiB

Extracted Text

® ™ AAC and CellSMART Multi-service Access Concentrators High-speed Consolidation of Hybrid Networks AAC-2 AAC-3 CellSMART Features ™ AAC Multi-service Access Concentrators cost-effectively connect voice, video and data Scalable architecture provides flexibility as network requirements change traffic to private Wide Area Networks (WAN) and public ATM and Frame Relay services Multi-service access in a single device reduces recurring monthly access costs worldwide. Supporting multiple protocols, NxT1/E1 inverse multiplexing for cost- physical interfaces and a wide range of effective network expansion ® bandwidth requirements, AAC and CellSMART Large variety of available interfaces products allow organizations and service supply serial ports, Frame Relay and providers to consolidate hybrid facilities for T1/E1, NxT1/E1 IMA, T3/E3, and OC-3/STM-1 to deliver specific services reduced costs and more efficient management for customer applications of broadband networks. Standards compliance for inter- operability with multi-vendor network Comprehensive ATM WAN service management for monitoring ATM services via SNMP and Telnet www.kentrox.com AAC and CellSMART Multi-service Access Concentrators Flexible System Architecture The AAC family offers a flexible, modular architecture, Integrated System Front Panel Alarm Module Slot 1 Controller (Protocol allowing you to choose the most cost-effective service Packet V.35 Modules) Slot 2 for each application and manage everything from a OC-3 Slot 3 Cell single platform. Each AAC contains slots for Protocol Cell E3 Modules (PM) that determine the traffic type—ATM Slot 4 or Frame Relay—and Physical Layer Modules (PLM) CES Octal DS1 Slot 5 that determine the physical interface type. The broad Packet T3 Slot 6 array of available Protocol and Physical Layer Modules Slot 7 Cell T1/E1 IMA meets the needs of a variety of customers, including Slot 8 HSSI Packet enterprise, service provider, government and military. Rear Panel (Physical Layer Modules) Figure 1: AAC modular architecture Interface OC-3/STM-1 IMA V.35, X.21 SM or MM T3/E3 T1/E1 T1/E1 EIA-530 HSSI Protocol ATM UNI • • • • Frame Relay • • • • HDLC or PPP • • • • CBR (CES) • • • • Figure 2: The AAC family supports a variety of protocols and network interfaces. Enhanced Quad Protocol Modules Shaping Octal CES Quad Packet/CBR Cell PM Cell PM PM Packet PM Packet PM PM Physical Layer Modules (10200) (10204) (10207) (10201) (10205) (10203) DS3 PLM (10300) • • • • HSSI PLM (10301) • • Quad DSX-1 PLM (10302) • • OC-3c/STM-1 MM PLM (10304) • • OC-3c/STM-1 SM PLM (10305) • • E3 PLM (10306) • • • • Quad V.35/530 PLM (10309) • • • • Octal DSX-1 PLM (10314) • Octal E1 PLM (10315) • Octal DS1 PLM (10317) • Octal DS1 IMA PLM (10318) • • Octal E1 IMA PLM (10319) • • Figure 3: AAC PM/PLM compatibility matrix.  AAC and CellSMART Multi-service Access Concentrators • The CellSMART 200 IMA series is the most economi- The AAC family comprises three models to deliver a full cal system, ideal for medium-speed to high-speed data range of access options at a variety of price points. applications that require NxT1/E1 access using Inverse • The AAC-3 offers the highest levels of connectivity Multiplexing for ATM (IMA). A variety of models are and scalability, supporting speeds ranging from T1/E1 available with V.35, HSSI, T3/E3 or OC-3c/STM-1 user to OC-3c/STM-1. Its modular chassis supports up to ports. seven PM/PLM pairs, making it an ideal hub device for The high port density and modular architecture lets enterprise networks or a port fan-out device for service each network grow and upgrade at a minimal cost. As distribution. service or application needs change, customers just add • The AAC-2 has a smaller chassis which supports up to or switch modules while maintaining a common chassis three PM/PLM pairs, making it suitable for mid-sized and management interface. For instance, with an Octal locations that need to connect voice, video and data IMA Physical Layer Module, T1/E1 circuits can be steadily traffic to the WAN. added as bandwidth needs increase. Network Applications Central Site Branch Office ATM LAN Router Switch OC-3c HSSI T1/E1 T1/E1 PBX PBX OC-3c T3/E3 AAC-2 AAC-3 V.35 V.35 Video Video Public or Private ATM Service or Frame Relay OC-3c Router T1/E1 PBX T1/E1 N x T1/E1 CellSMART 200 AAC-2 V.35 Router Data Warehouse Remote Site Figure 4: The AAC family of multi-service access concentrators connects central, branch and remote locations via public or private ATM or Frame Relay services. Local Campus Q2200 T1 Q2200 T1 Frame Relay Private Line DS-1 Headquarters Frame Frame Relay Relay DS-1 Frame Relay Router DS-1 Q2200 AAC-2 Frame Relay DS-1 Frame Relay Frame Relay DS-1 Q2200 Remote Offices Figure 5: Use the AAC to aggregate traffic from Q-Series routers located at branch offices.  AAC and CellSMART Multi-service Access Concentrators Element Management Standards Compliance The AAC family supports local and remote access via in- AAC products comply with the following standards to band or out-of-band connections. All products include alleviate compatibility issues in multi-vendor networks and an embedded SNMP agent and standard and enterprise reduce the risks associated with proprietary solutions. MIBs, compatible with SNMP-based management systems. You can also Telnet to the devices via the • The ATM Forum, including: Ethernet port on the Integrated System Controller or an - Inverse Multiplexing for ATM (IMA) 1.1/1.0 in-band ATM/Frame Relay connection. The native user interface is menu-driven, making port and connection - ATM UNI 3.0 and 3.1 configuration quick and easy. - Traffic Management 4.0 with support for CBR, rt-VBR, nrt-VBR and UBR QoS categories Traffic Management You can maximize the utilization of expensive - Circuit Emulation Services 2.0 with support for wide-area bandwidth with AAC traffic management structured or unstructured CES features. The Enhanced Shaping Cell Protocol Module • ITU-T performs traffic shaping on a per-VC and per-VP basis, • Bellcore/Telcordia ensuring that traffic meets the rates contracted with your carrier. This prevents cell discard and retransmissions, • The Frame Relay Forum improving the overall use of available bandwidth. Other AAC modules increase bandwidth utilization by reallocating idle CBR bandwidth. Protect your network investment with support plans and technical training Performance Monitoring To keep your network healthy and productive, Kentrox AAC systems collect extensive statistics, including port offers Kentrox Care Support Plans for AAC and and cell utilization, cell and packet discard, and physical CellSMART access concentrators. Kentrox technical line errors. You can view the information in table or training courses are also available on site or at the Kentrox graphical form to monitor network performance, campus to help you get the most out of your access anticipate growth in bandwidth requirements and concentrators. For details, visit our website at troubleshoot problems in both the local and wide www.kentrox.com. area networks. Site 1 Frame Relay on HSSI NxT1/E1 ATM IMA DataSMART Router or Q-Series Router AAC-2 T1 ATM Network T1 DataSMART Router or Q-Series Frame Relay Frame Relay ATM Network on DS3 on HSSI Router AAC-2 T1 DataSMART Router or Q-Series Site 2 Figure 6: The Kentrox AAC supports Frame Relay to ATM service internetworking.  AAC and CellSMART Multi-service Access Concentrators ORDERING INFORMATION DESCRIPTION CATALOG # CellSMART 205t, T1 Octal IMA to DS-3, Chassis and Power Supplies 100 to 240VAC 20009-310 AAC-3 Eight-slot Chassis 10000 CellSMART 205e, E1 Octal IMA to E3, AAC-3 DC Power Supply 10101 100 to 240VAC 20010-310 AAC-3 Universal Input Power Supply 100-240VAC 10103 AAC-2 Four-slot Chassis 10001 Accessories AAC-2 DC Power Supply 10111 AAC-3 Fan Tray Assembly (Spare) 10080 AAC-2 Universal Input Power Supply 100-240VAC 10113 AAC Blank Panel, 1 Slot (Spare) 10082 AAC-3 Blank Panel, Power Supply (Spare) 10084 Common Modules AAC Manual Set, CD (Spare) 10090 AAC Integrated System Controller 10022 AAC Planning Guide, printed 10091 AAC System Controller 10010 AAC Alarm Module 10011 Power Cords AAC Extension Module 10021 North America, Korea, Taiwan 90000 European Community 90001 Protocol Modules United Kingdom 90002 AAC Cell Protocol Module 10200 Italy 90003 AAC Packet Protocol Module 10201 AAC Quad Packet / CBR Protocol Module 10203 KENTROX CARE SUPPORT PLANS CATALOG # AAC Enhanced Shaping Cell Protocol Module 10204 Onsite 7x24x4: AAC components 13203 AAC Quad Packet Protocol Module 10205 Onsite 7x24x4: CellSMART 13603 AAC Octal CES/CBR Protocol Module 10207 Onsite 5x8x4: AAC components 13213 Onsite 5x8x4: CellSMART 13613 Physical Layer Modules Onsite 7x24xNBD: AAC components 13202 Onsite 7x24xNBD: CellSMART 13602 AAC DS3 Physical Layer Module 10300 Onsite 5x8xNBD: AAC components 13212 AAC HSSI Physical Layer Module 10301 Onsite 5x8xNBD: CellSMART 13612 AAC Quad DSX-1 Physical Layer Module 10302 Basic 7x24xNBD: AAC components 13204 AAC OC-3c/STM1 MM Fiber Physical Layer Module 10304 Basic 7x24xNBD: CellSMART 13604 AAC OC-3c/STM1 SM Fiber Physical Layer Module 10305 Exchange NBD: AAC components 13209 AAC E3 Physical Layer Module 10306 Exchange NBD: CellSMART 13609 AAC Quad V.35/EIA-530/X.21 Physical Layer Module 10309 Onsite Installation: AAC components 13100 AAC Octal (8-port) DSX-1 Physical Layer Module 10314 Onsite Installation: CellSMART 14105 AAC Octal (8-port) E1 Physical Layer Module 10315 AAC Octal (8-port) DS1 (CSU) Physical Layer Module 10317 AAC Octal (8-port) IMA DS1 Physical Layer Module 10318 AAC Octal (8-port) IMA E1 Physical Layer Module 10319 CellSMART 200 ATM IMA Systems For details on Kentrox Care Support CellSMART 201t, T1 Octal IMA to HSSI, Plans and AAC/CellSMART training, 100 to 240VAC 20001-310 visit www.kentrox.com or call CellSMART 201e, E1 Octal IMA to HSSI 800-7-11. 100 to 240VAC 20002-310 CellSMART 202t, T1 Octal IMA to V.35,(8 Mbps), 100 to 240VAC 20003-310 CellSMART 202e, E1 Octal IMA to V.35 (8 Mbps), 100 to 240VAC 20004-310 CellSMART 204t, T1 Octal IMA to OC-3c/STM-1, 100 to 240VAC 20007-310 CellSMART 204e, E1 Octal IMA to OC-3c/STM-1, 100 to 240VAC 20008-310  AAC and CellSMART Multi-service Access Concentrators SPECIFICATIONS AAC-3 ChAssis SYSTEM MODULES Dimensions (H x W x D) 13.95” x 17.32” x 19” (354.3 x 440 x 482.6 mm) One ISC module is required in every AAC/CellSMART chassis. Weight 60 lbs. (27 kg) Mounting Available for 19-inch or 23-inch standard integrAted system Controller (isC) equipment racks Clock sources Internal reference oscillator or recovered from Operating Temperature 32º F to 104º F, ambient (0° C to 40° C) user-specified physical port Operating Humidity 5% to 95%, non-condensing Clock fallback User-selectable primary and secondary clock source with automatic fallback and recovery AAC-2 And CellsmArt 200 ChAssis Internal reference Oscillator Stratum 4 or better Dimensions (H x W x D) 6.95” x 17.32” x 19” (176.5 x 440 x 482.6 mm) Power loss protection Loss of all input line power will not affect the Weight 29 lbs. (13.2 kg) configuration settings; performance data will be Mounting Available for 19-inch or 23-inch standard maintained for 12 hours upon loss of power equipment racks Alarm Critical, Major, and Minor alarm indicators are Operating Temperature 32º F to 104º F, ambient (0° C to 40° C) viewable from the rear Operating Humidity 5% to 95%, non-condensing Contact closure for audible and visual alarms ACO (Automatic Cut Off) button disables switChing BACkplAne audible alarms Cell bus Dynamic time-allocated, output buffered per port Configuration backup Pluggable Type II compact flash or connection Management access Ethernet port and DTE asynchronous port for dial- Maximum up modem (in addition to front panel port) system throughput 524 Mbps (1,168,000 cells/second) Connections 8192 VCCs, 512 VPCs, 512 Multicast AlArm module (optional) Indicators Critical, Major and Minor alarm indicators are mAnAgement ACCess viewable from the front Control port VT100 via RS232 port on front panel (Additional Alarm ACO (Automatic Cut Off) button disables audible RS232 port on the Integrated System Controller) alarms Ethernet port SNMP or Telnet Configuration backup Flash In-band SNMP or Telnet Telnet sessions Up to 4 concurrently with the Integrated System Controller power system AAC-3 Dual redundant power system. Modular power supplies, field replaceable with unit powered. Monitored with alarms/traps on failure. Forced-air cooled. Supports mixed use of AC/DC power modules. AAC-2 and CellSMART 200 Single power system. Modular power supply. Monitored with alarms/traps on failure. Forced-air cooled. Supports use of AC/DC power modules. AC power supply 120/240 VAC (85 to 264 volts), 50/60Hz +/- 3Hz DC power supply -48 VDC (42 to 60 VDC) emC, sAFety, And neBs Terminal 47 CFR 68, CS.03 Emissions 47 CFR 15, EN55022, Class A Immunity EN55024 Safety CSA 60950-1-03/UL 60950-1 NEBS Level 3 certified  AAC and CellSMART Multi-service Access Concentrators SPECIFICATIONS (continued) PROTOCOL MODULES PHYSICAL LAYER MODULES See the PM/PLM compatibility matrix, Figure 3, for available See the PM/PLM compatibility matrix, Figure 3, for available Protocol and Physical Layer Module combinations. Not all Protocol and Physical Layer Module combinations. Not all modules are listed. modules are listed. Cell protoCol module oCtAl imA ds1 And e1 physiCAl lAyer modules Protocols supported ATM UNI Interface connector RJ48C Connections 256 VPCs, 4096 VCCs or combinations thereof up Line rate T1 - 1.544 Mbps per port to 4096 total connections E1 - 2.048 Mbps per port QoS categories CBR, nrt-VBR and rt-VBR IMA rate T1 - 1.536 to 12.288 Mbps Output queuing Separate CBR and VBR output queues with traffic E1 - 1.984 to 15.872 Mbps and congestion management capability. Differential delay Up to 200 ms Total queue depth: 4700 cells ACP sync cells User selectable at 32, 64, 128 or 256 cells Maximum burst size 32, 105, 210 or maximum cells Link adjustment Automatic adjustment on link failure or recovery Cell emission scheduling Per port for VBR traffic only or aggregate (CBR and VBR) traffic oCtAl ds1, dsX-1 And e1 physiCAl lAyer modules Congestion management Early packet discard (EPD) and 4 VBR priorities, Interface connector RJ48C CBR not subject to congestion, Partial Packet Line rate DS1 (includes CSU) - 1.544 Mbps per port Discard (PPD)Packet PROTOCOL MODULE/Quad DSX-1 - 1.544 Mbps per port Packet E1 - 2.048 Mbps per port Channelization NxDS0 up to full line rate protoCol module Protocols supported Frame Relay, ATM DXI, HDLC, PPP QuAd dsX-1 physiCAl lAyer module Frame Relay connections Packet PM: 2048 VCCs (AAL5) or DLCIs Interface connector DA15 Quad Packet PM: 512 VCCs (AAL5) or DLCIs Line rate DSX-1 - 1.544 Mbps per port per port Fractionalization NxDS0 up to full line rate Services supported FRF.5, FRF.8 (1490 to 1483 translation) and FRLM Congestion management Partial and early packet discard (EPD) and 4 VBR QuAd V.35/eiA-530 physiCAl lAyer module priorities Interface connector DB25 Electrical V.35, RS449, EIA-530, X.21 oCtAl Ces protoCol module Line speed 64 Kbps to 2.048 Mbps on each of four ports or Protocols supported Structured or unstructured circuit emulation over up to 8.192 Mbps on one port AAL1 Dynamic bandwidth allocation based on hssi physiCAl lAyer module CAS signaling, idle code detection, or V.35 Interface connector TIA/EIA-613 standard 50 position control signals Line speed 1 Mbps to 52 Mbps Connections 32 unicast or multicast per port, 256 per module Output queuing User-selectable depth of CDV absorption queue ds3 And e3 physiCAl lAyer modules to 1 ms Interface connector 75 ohm coaxial BNC Clocking Synchronous or asynchronous (Adaptive) Line rate DS3 - 44.736 Mbps Logical bundles 1 DS0 to 24 DS0s (T1) or 31 DS0s (E1) E3 - 34.368 Mbps oC-3C/stm1 single And multi-mode physiCAl lAyer modules Interface connector Duplex SC Line speed 155.52 Mbps Wavelength 1310 nm (single-mode or multi-mode) 7 AAC and CellSMART Multi-service Access Concentrators For more information, call our pre-sales Applications Support Team at 800-7-11 or visit www.kentrox.com. 05-06-018-1 7/05 Copyright © 2004-2005 by Kentrox, LLC. All Rights Reserved. Kentrox and CellSMART are registered trademarks and AAC is a trademark of Kentrox, LLC. Information published here is current as of this document’s date of publication, but is subject to change without notice. You may verify product information by contacting our headquarters in Hillsboro. Kentrox is an Equal Opportunity Employer and Affirmative Action compliant. Kentrox, LLC 20010 NW Tanasbourne Dr. Hillsboro, OR 97124 Phone 503-643-1681 Service and Support 800-733-5511 www.kentrox.com 8

Frequently asked questions

What makes Elite.Parts unique?

chervon down
At GID Industrial (Elite.Parts' parent company), we specialize in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

What kind of warranty will the 20001-310 have?

chervon down
Warranties differ by part and by which suppliers we use to procure it for you. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carriers does Elite.Parts work with?

chervon down
Elite.Parts can ship via FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Will Elite.Parts sell to me even though I live outside the USA?

chervon down
Absolutely! We are happy to serve customers regardless of location. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

I have a preferred payment method. Will Elite.Parts accept it?

chervon down
All major credit cards are accepted: Visa, MasterCard, Discover, and American Express. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

AAC-3 CHAS SLOT ATM CHAS

AAC-3 4 SLOT CHASSIS

AAC SYS CTRL MOD S/W 2.2.6

AAC-3 EXTENSION MODULE

AAC INTEGRATED SYSTEM CTRL S/W

AAC INTEGRATED SYSTEM CTRL V.3.2