Specifications
Common Mode Rejection
= 100db 50 Hz-60 Hz1
Conversion Rate
2.5 per second
Decimal Point
Three positions, external selection
Digit Height
0.5" (12.7 mm)
Meter Function
DC Volts
Meter Range
0V to 2V
No. of Digits / Alpha
3-1/2
Normal Mode Rejection
= 40 db 50Hz-60Hz
Operating Temperature Range
-20°C to +60°C
Overload
Three lower digits blank for readings greater than 1999
Polarity
Automatic (-) displayed
Power Consumption
2VA
Supply Voltage Range
97.75VAC to 126.5VAC
Tempco
±200 PPM/°C typical2
Warmup
10 minutes
Weight
2 oz.
Zero Adjust
Automatic
Features
- Custom labels for special readouts
- Red or green backlit display
- Scalable in engineering units
- User Selectable functions, decimal point, offset, span, process voltage or current, DC voltage
Datasheet
Extracted Text
2000 Series Digital Panel Meters 2100 Series with DIP switch selections and multiple power options. Backlighting Options • Positive Green Black on Green Background • Negative Green Green on Black Background • Positive Red Black on Red Background • Negative Red Red on Black Background • Non-Backlit LCD Black on Grey Background Customize for features that are important to you and rely on industry standards for routine digital PM elements. You need flexibility. We provide it. We customize our meters to meet your specifications. • Scalable in engineering units • Custom labels for special readouts • User Selectable functions, decimal point, offset, span, process voltage or current, DC voltage Applications • Red or green backlit display � Telecommunications You need reliability. The MODUTEC 2000 Series operates in the � Water Purification harshest environments. • Splash and hose proof meeting NEMA 4, NEMA 12, and IPC 55 standards � Sewage Treatment • Resistant to damage with a high impact polycarbonate case � Flow • Wide operating temperature ranging from -4°F to +140°F (-20°C to +60°C) � Process You need standards. The MODUTEC 2000 Series gives you industry � standards designed in. Desalinization • 1/8 DIN industry standard cut-out and 1 inch depth � Temperature • Screw terminals � • Over range indication AC & DC Amps • Low cost � AC & DC Volts • The MODUTEC 2100 includes user-friendly dipswitch selection features sales@jewellinstruments.com www.jewellinstruments.com 800 638-3771 • • mm 2000 & 2100 Series Dimensional Drawings ( ) /in Panel Cutout Front View Side View Non-backlit Side View Backlit 92 7.1 7.1 96 A A 3.620 .28 .28 3.78 .25R MAX (4) 42.9 42.9 .010R 45 48 1.770 1.69 1.69 1.89 DC VOLTS Panel Cutout Notes: B B 1. For optimum water resistance Rear View Figure A Figure B use cutout height of 43 MM (1.693 Inches). 89.9 3.54 Input Type Figure A (mm/in) B (mm/in) 2. Panel thickness .81 to 6.35 MM (.032 to .250 Inches). AC A 25.1/.99 29.2/1.15 DC A 25.1/.99 29.2/1.15 Temperature A 25.1/.99 29.2/1.15 4-20mA Process B 37.8/1.49 50.8/2.00 Frequency A 25.1/.99 29.2/1.15 AC Power 2000 and 2100 Series Specifications Display Connection for High Current Measurement 1 / Digits: 3 digits, 7 segments Backlit LCD (1999) Digit Height: 0.5" (12.7 mm) 2 Polarity: Automatic (-) displayed Decimal Point: Three positions, external selection Overload: Three lower digits blank for readings AC Amps greater than 1999 300:5A Performance User Provided Transformer Supplied With Meter Conversion Rate: 2.5 per second Normal Mode Rejection: ≥ 40 db 50Hz-60Hz 1 Common Mode Rejection: ≥ 100db 50 Hz-60 Hz Zero Adjust: Automatic 2 Tempco: ±200 PPM/°C typical Warmup: 10 minutes Environment Operating Range: -4°F to 140°F (-20°C to + 60°C) Storage Range: -22°F to 158°F (-30°C to + 70°C) Power Options 115V +10%, -15% 50Hz to 400Hz at 2VA 230V +10%, -15% 50Hz to 400Hz at 2VA 10 to 28VDC 150 mA (including backlighting) 10 to 15VDC or 20 to 32VDC 150mA (including backlighting) Weight 2 oz. FCC Compliance Complies with the class B Limits of FCC rules and regulations, part 15, sub part J for conducted and radiated emissions. 1 except isolated DC powered which is ≥ 80 db 50 Hz-60Hz 2 except thermocouple inputs which are .1°/ degree zero tempco for selectable process ranges is only ±.2 count/°C Specifications continued on back page. sales@jewellinstruments.com www.jewellinstruments.com 800 638-3771 • • V+ IN HI IN LO DP1 DP2 DP3 AC LO AC HI 2000 & 2100 Series Connection Drawings Universal Switchable — Model 2100 AC and DC Inputs (AC and Isolated DC power) Terminal Description Terminal Description IN+ V+ 10-28VDC power input Signal Input IN– IN HI Signal Input AC Power Low AC Power Input, 115VAC or 230VAC IN LO AC Power HI depending on model selected DP1, DP2, DP3 — Decimal point selection, connect to V+ as follows: DP1=XXX.X, DP2=XX.XX, DP3=X.XXX AC Power AC Power LO AC Power AC Power Input, 115VAC or 230VAC AC Power HI depending on model selected 12V 12VDC Power GND 12VDC power input (optional) Power GND 12VDC power input 24VDC power input (optional) 24V 24VDC power input 24VDC Power GND Power GND DC Power 12 or 24VDC (Optional) Power Option Frequency Input 4-20mA Process & Flow Inputs Terminal Description Terminal Description AC LO Signal input and power, 115VAC IN+ Ranging Header Signal Input AC HI or 230VAC depending on model IN– Zero Span Earth GND selected. DP1, DP2, DP3 — Decimal point selection, connect to V+ as follows: DP1= XXX.X, DP2= XX.XX, 12VDC DP3= X.XXX Power GND 12VDC power input (optional) 24VDC power input 24VDC V+ DC voltage output to select Power GND decimal points DC Inputs (Non-Isolated DC Power) Temperature Inputs Terminal Description Terminal Description V+ TC+ 10-28VDC power input Thermocouple Inputs V– TC– IN HI AC Power Low AC Power Input, 115VAC or 230VAC Signal Input IN LO AC Power HI depending on model selected BL + 1 Backlight power input BL – 2 RTD inputs 3 DP1, DP2, DP3 — Decimal point selection, connect to V+ as follows: DP1=XXX.X, DP2=XX.XX, DP3=X.XXX 123 2000 Series Scaling Chart Scaling Capability Zero Range Adjustment Model 2100, of the 2000 Series, provide the 4mA to 20mA, 1V to 5V -1000 counts to +1500 counts. Switch selectable in four ranges: unique ability to switch-select a range and a 25-turn potentiometer enables continuous adjustment. then scale and offset that range. Input will be displayed in engineering units. For 0 to 200mV, 0 to 2V, 0 to 10V -1500 counts to +1500 counts. Switch selectable in six ranges: example, by changing switch positions and a 25-turn potentiometer enables continuous adjustment. recalibrating, a 2133-3419-04 may be set-up Full Scale Span Adjustment for any of the following displays: All ranges 0 to 2000 counts. Switch selectable in four ranges: • 4 to 20mA input display -148°F to 932°F a 25-turn potentiometer enables continuous adjustment. (-100°C to +500°C) temperature • 1 to 5V input displaying – 60kPa to Other ranges and scaling available. 300kPa differential pressure • 0 to10V input displaying +700°F to +950°F (+682°C to +932°C) temperature • 0 to 50mV input displaying 0 to 300 amperes sales@jewellinstruments.com www.jewellinstruments.com 800 638-3771 • • V+ V– 12 VDC IN HI DC GND IN LO IN + IN + 24 VDC BL+ IN – IN – EARTH GND BL– 12 VDC AC LO DP1 PWR GND AC LO AC HI DP2 24 VDC AC HI DP3 °F Zero IN+ V+ V+ °C °F/°C IN– IN HI IN HI Selection IN LO IN LO DP1 °F Span DP1 DP1 DP2 °C DP2 DP2 TC+ DP3 12V DP3 V+ PWR GND AC LO TC– 24V AC HI AC LO AC HI How to Order 2000 and 2100 Series Specifications (continued) a b c d e f 1 2 03 3 -3 4 61 - 04 2 DC Inputs Accuracy Input Resistance Overload Protection 200mVDC & 2VDC ±(.1% +1 count) typical ≥ 100 Meg Ohms 200V continuous Configuration a ±(.2% +1 count) max. 300V intermittent 0 = 1/8 DIN 1 = UPM 2 = TRMS (Inst) 3 = TRMS (Power) 20VDC & 200VDC ±(.1% +1 count) typical 1 Meg Ohm 350V continuous ±(.2% +1 count) max. 500V intermittent Display 1 = Non Bklit 3 = Pos Grn Bklit b DC Current ±(.1% +1 count) typical 200mV drop full scale 3 times f.s. current 4 = Neg Grn Bklit 5 = Neg Red Bklit ±(.2% +1 count) max. 6 = Pos Red Bklit Universal Selectable ±(.1% +2 counts) 4 to 20mA, 10 Ohms 4 to 20 mA, ±100mA 2 DPM Power Process ≥ 200mV, ≥ 200K Ohms Voltage Inputs, 0 =loop power 1 = 9 VDC 2V and up, ≥ 1Meg Ohm 200V continuous 2 =±5VDC 3 = +5 volts c 300V intermittent 4 =115VAC 5 = 230VAC 6 =10 to28VDC 7 = 12 or 24VDC (Iso) 8 =12 VDC 9 = 24VDC AC Inputs Accuracy Input Resistance Overload Protection AC Voltage ±(.5% + 1 count) 1 Meg Ohm 350V continuous Input 500V intermittent 00 = 100mVDC (1999 counts) 01 = 200mVDC scaled 0 to 199.9 5A AC Current ±(.5% +1 count) Current transformer 3 times f.s. current 02 = 2VDC scaled 0 to 1.999 03 = 20VDC 50A AC Current ±(.5% +5 counts) Current transformer 3 times f.s. current 04 = 200VDC 05 = 1V to 5 VDC scaled 0 to 100.0 Frequency Inputs Accuracy Distortion 06 = 10VDC scaled 0 to 10.00 40.0 to 199.9Hz ±.2Hz (40 to 70Hz) ≤ .1 Hz for up to 20% third harmonic distortion 07 = 500VDC ±.5Hz (above 70Hz) 10 = 200uADC 11 = 2mADC 40 to 440Hz ±1Hz ≤ .1 Hz for up to 20% third harmonic distortion 12 = 20mADC 13 = 200mADC 3 18 = 4 to 20mADC Sq Rt Temperature Inputs Accuracy Input Characteristic Overload Protection 3 19 = 4 to 20mADC scaled 0 to 100.0 Type J thermocouple 21 = 200.0mVAC RMS -10°F to +1200°F ±(.1% +1 count) accuracy 45 uV max per 100 Ohms 200V continuous 22 = 2.000VAC RMS (-23°C to +649°C) ±1.3°C (2.8°F) thermocouple lead resistance 23 = 20.00VAC RMS conformity error 24 = 200.0VAC RMS d 25 = 500VAC RMS Type K thermocouple 27 = 500VAC Avg -40°F to +1500°F ±(.1% +1 count) accuracy 45 uV max per 100 Ohms 200V continuous 28 = 80.0 - 130.0VAC Avg 29 = 80 - 260VAC Avg (-40°C to +815°C) ±1.2°C (2.5°F) thermocouple lead resistance 30 = 250VAC RMS conformity error 31 = 2.000mAAC RMS Type T thermocouple 32 = 20.00mAAC RMS 33 = 200.0mAAC RMS -100°F to +600°F ±(.1% +1 count) accuracy 45 uV max per 100 Ohms 200V continuous 34 = 2.000AAC RMS (-73°C to +315°C) ±1.5°C (3.5°F) thermocouple lead resistance 4 36 = 5.00AAC RMS conformity error 4 37 = 50.0AAC RMS 4 38 = 0 - 5AAC AVG 100 � Pt. � =.00385 4 39 = 0 - 50AAC AVG -200°F to +600° F ±(.2% + 1 count) max 1mA RTD current ±5V 60 = 40 to 440Hz (-129°C to +315°C) 61 = 40.0 to 199.9Hz 70 = 100 Ohms Pt 1° Resolution 100 � Pt. � =.00385 71 = 100 Ohms Pt .1° Resolution -100.0°F to +199.9°F ±(.2% + 1 count) max 1mA RTD current ±5V 80 = Type J Thermocouple (-73°C to +98°C) 81 = Type K Thermocouple 82 = Type T Thermocouple 1 Change Order Number to “4” for 200 VDC Input 2 Backlit Power 2 Backlit power must be the same as the selected DPM power. 00 = No Backlight 01 = 5VDC 3 e Available on Non-Backlit meters only. 02 = 12VDC 03 = 24VDC 4 Rated for use with 5A or 50A external current transformer 04 = 115VAC 05 = 230VAC supplied with DPM. See high current connection on inside page. 06 = 10 to 28VDC 07 = 12 or 24VDC 5 For 5A current transformer inputs only. 5 Display 1 = 2000 2 = 1500 3 = 1000 f 4 = 600 5 = 500 6 = 300 sales@jewellinstruments.com www.jewellinstruments.com 800 638-3771 • • 7 = 200 8 = 100 850 Perimeter Road Manchester, NH 03103 USA • •
Frequently asked questions
What makes Elite.Parts unique?

What kind of warranty will the 2053-3402-04 have?

Which carriers does Elite.Parts work with?

Will Elite.Parts sell to me even though I live outside the USA?

I have a preferred payment method. Will Elite.Parts accept it?

Why buy from GID?

Quality
We are industry veterans who take pride in our work

Protection
Avoid the dangers of risky trading in the gray market

Access
Our network of suppliers is ready and at your disposal

Savings
Maintain legacy systems to prevent costly downtime

Speed
Time is of the essence, and we are respectful of yours
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods