INTERGRATED POWER DESIGNS SRP-40A-2001
Specifications
Dimensions
Compact 2.5" X 4.25" X 1.2" Size
Efficiency
.66 -.72 (Varies by model)
Frequency Range
47-63 Hz
Input
Universal 85-264 VAC Input
Source Current
True RMS: 1A At 85V Input. Peak Inrush: 30A
Source Voltage
85-264 Voltage AC
Features
- Advanced SMT Design
- Class B Emissions Per EN 55022/11
- Compact 2.5" X 4.25" X 1.2" Size
- EMC to EN 61000-6-2 & EN 60601-1-2
- EN 60601-1 Medical Certification
- EN 60950 ITE Certification
- Fits 1U Application
- High Efficiency
- Optional Chassis & Cover
- Universal 85-264 VAC Input
Datasheet
Extracted Text
40 WATTS OUTPUT SPECIFICATIONS SRP-40A SERIES Features Total Output Power 40 W (33W, 1001) Output Voltage Output 1: +/-0.25% Centering(50% Load) Output 2: +/-5.00% Universal 85-264 VAC Input Output 3: +/-3.00% High Efficiency Output 4: +/-3.00% Advanced SMT Design (All outputs at 50% rated load) Compact 2.5" X 4.25" X 1.2" Size Source Regulation Outputs 1-4: 0.5% Class B Emissions Per EN 55022/11 Load Regulation (Local Sense) EMC to EN 61000-6-2 & EN 60601-1-2 Output 1:0.5% (10-100% Load 2 Year Warranty Change) Fits 1U Application (30-100% Output 2: 5.0% EN 60950 ITE Certification Load Change) (30-100% EN 60601-1 Medical Certification (2003, 4002) 7.0% Load Change) Optional Chassis & Cover (10-100% Output 3: 0.5% Load Change) (10-100% Output 4: 0.5% Load Change) Cross Regulation Output 2: 5.0% Output 3: 0.5% Output 4: 0.5% (Output 1 load varied 50-100%) Output Voltage Adjust Output 1: 95% to 105% Range Output Noise Outputs 1-4: 1% Turn On Overshoot None Transient Response Outputs 1-4 Volt. Deviation 5% Recovery Time 2 mS Load Change 50% To 100% Output Overvoltage Output 1: 110% to 150% Protection (Optional) Output Overpower Output 1&2 110% Min. Protection Outputs cycle on/off, auto recovery Output Overcurrent Output 3&4 110% Min. Protection Hold Up Time 10 mS Min, 40 W Output 120 V Input Start Up Time 1 Second INPUT SPECIFICATIONS ENVIRONMENTAL SPECIFICATIONS oo Source Voltage 85-264 Voltage AC 0 C to +70 C Derating: Ambient Operating Frequency Range 47-63 Hz See Power Rating Chart Temperature Range Source Current Ambient Storage oo -40 C to +85 C True RMS 1A At 85V Input Temperature Range Peak Inrush 30A o Outputs 1-4: 0.02%/ C Temperature Coefficient Efficiency .66 -.72 (Varies by model) Authorized Distributor: TRC Electronics, Inc. Tel: 973.779.8282 Fax: 973.779.1490 www.trcelectronics.com SAFETY SPECIFICATIONS GENERAL SPECIFICATIONS General Protection Class: I Dielectric Strength Reinforced Insulation5656 VDC, Primary to Secondary, 1 Sec. Overvoltage Category: II Basic Insulation2121 VDC, Primary to Ground, 1 Sec. Pollution Degree: 2 Operational Insulation 707 VDC, Secondary to Ground, 1 Sec. Underwriters UL 60950, Third Edition Leakage Current <300 ÂIA Earth Leakage Laboratories UL 2601 - 1 Second Current File E137708 Edition Mean Time Between 100,000 Hours min., CB Report Per IEC 950 o Failures MIL-HDBK-217F, 25 C, GB (1991) Weight 0.85 Lbs. Chassis and Second Edition A1, A2, A3, Cover A4 0.49 Lbs. Open Frame All EN 60950 Deviations ELECTROMAGNETIC COMPATIBILITY CB Report Per IEC Electrostatic EN 61000-4-2 +/-8kV Contact 601-1-1988 Discharge Discharge First Edition, A1, A2 +/-8kVAir UL Recognition CAN/CSA-C22.2 No. Discharge Mark for 60950:00 Radiated EN 61000-4-380MHz-2.5GHz, Canada CAN/CSA-C22.2 No. Electro-magnetic 10V/m, 80% AM File E137708 601-1-M90 Field TUV EN 60950/A11:1997 EFT/Bursts EN 61000-4-4 +/-2kV EN 60601-1/A2: 1995 Surges EN 61000-4-5 +/-1 kV Differential Low Voltage Directive Mode +/-2 kV Common Mode Conducted EN 61000-4-6 .15-80MHz., 10V, Notes Immunity 80% AM Consult factory for alternate output configuration. Voltage Dips and EN 30% Reduction Consult factory for positive, negative or floating Interruptions 61000-4-11 95% Reduction output 2 or 3. 60% Reduction Refer to Application Information for complete output power ratings. 95% Reduction All specifications are maximum at 25C unless Radiated EN 55011/22 Class B otherwise stated and are subjected to change Emissions without notice. Conducted EN 55011/22 Class B Specify optional chassis and cover when ordering. Emissions MODEL LISTING Model Output 1 Output 2 Output 3 Output 4 Max Power SRP-40A-4001 +3.3V/5A +5V/3A +12V/.7A -12V/.7A 40W SRP-40A-4002 +5V/5A +3.3V/3A +12V/.7A -12V/.7A 40W SRP-40A-4003 +5V/5A -5V/3A +12V/.7A -12V/.7A 40W SRP-40A-4004 +5V/5A -5V/3A +15V/.7A -15V/.7A 40W SRP-40A-4005 +5V/5A +24V/1.5A +12V/.7A -12V/.7A 40W SRP-40A-4006 +5V/5A +24V/1.5A +15V/.7A -15V/.7A 40W SRP-40A-3001 +5V/5A +12V/2A -12V/.7A 40W SRP-40A-3002 +5V/5A +15V/2A -15V/.7A 40W SRP-40A-2001 +5V/5A +24V/1.5A 40W SRP-40A-2002 +5V/5A +12V/3A 40W SRP-40A-2003 +5V/5A -5V/4A 40W SRP-40A-2004 +12V/3A -12V/3A 40W SRP-40A-2005 +15V/2.5A -15V/2A 40W SRP-40A-1001 3.3V/10A 33W SRP-40A-1002 5V/8A 40W SRP-40A-1003 12V/3.33A 40W SRP-40A-1004 15V/2.67A 40W SRP-40A-1005 24V/1.67A 40W SRP-40A-1006 48V/0.83A 40W Authorized Distributor: TRC Electronics, Inc. Tel: 973.779.8282 Fax: 973.779.1490 www.trcelectronics.com SRP-40A SERIES MECHANICAL SPECIFICATIONS Authorized Distributor: TRC Electronics, Inc. Tel: 973.779.8282 Fax: 973.779.1490 www.trcelectronics.com Authorized Distributor: TRC Electronics, Inc. Tel: 973.779.8282 Fax: 973.779.1490 www.trcelectronics.com APPLICATIONS INFORMATION Each output can deliver its rated current but This power supply has been safety approved 1. 11. total output power must not exceed and final tested using a DC 40 watts(33W, 1001). dielectric strength test. Please consult factory Maximum ambient temperature is reduced to 40 before performing AC dielectric strength test. 2. C with optional chassis and cover. Semiconductor case temperature must not Maximum Output Power vs. Ambient 3. Temperature exceed 110 C Sufficient area must be provided around 4. convection cooled power supplies to allow natural movement of air develop. This product is intended for use as a 5. professionally installed component within information technology and medical equipment. A minimum load of 10% is required on output 6. one to insure proper regulation of remaining outputs. Remote sense terminals may be used to 7. compensate for cable losses up to 250mV. The use of a twisted pair is recommended as well as a decoupling capacitor (0.1 0 10microF) and a capacitor of 100microF/amp connected across CONNECTOR SPECIFICATIONS the load. .156 friction lock header mates 8. Peak to peak output ripple and noise is with Molex 09-50-3031 or measured directly at the output equivalent crimp terminal terminals of the power supply, without the use P1 AC Input housing with Molex of the probe ground lead or retractable tip, 20 08-50-0189 or equivalent MHz bandwidth. crimp terminal. 9. This product is use only one fuse in the input .156 friction lock header mates circuit. In consideration of clause 57.6 of UL with Molex 09-50-3061 or 2601-1, a second fuse may be required in the DC equivalent crimp terminal end product. P3 Output(Single) housing with Molex 10. This product was type tested and safety 08-50-0189 or equivalent certificated using the the dielectric strength test crimp terminal. voltages listed in Table V of UL 60601-1. In .156 friction lock header mates consideration of clause 20.4g, care must be with Molex 09-50-3081 or taken to insure the voltage applied to a DC equivalent crimp terminal reinforced insulation does not over stress basic P3 Output(Multiple) housing with Molex insulation. Secondary to ground capacitors may 08-50-0189 or equivalent need to be removed prior to performing a crimp terminal. dielectric strength type test on the end product. .100 friction lock header mates It is highly recommended that the DC test with Molex 22-01-2027 or voltages listed in DVB.1. Annex DVB are not Sense equivalent crimp terminal exceeded during a production-line dielectric P4,5 housing with Molex strength test of the assembled end product. 08-50-01114 or equivalent Please consult factory for further information. crimp terminal. G Ground .187 quick disconnect terminal. RECOMMENDED AIR FLOW DIRECTION Optimum 1. Good 2. Fair 3. Authorized Distributor: TRC Electronics, Inc. Tel: 973.779.8282 Fax: 973.779.1490 www.trcelectronics.com
Frequently asked questions
What makes Elite.Parts unique?

What kind of warranty will the SRP-40A-2001 have?

Which carriers does Elite.Parts work with?

Will Elite.Parts sell to me even though I live outside the USA?

I have a preferred payment method. Will Elite.Parts accept it?

Why buy from GID?

Quality
We are industry veterans who take pride in our work

Protection
Avoid the dangers of risky trading in the gray market

Access
Our network of suppliers is ready and at your disposal

Savings
Maintain legacy systems to prevent costly downtime

Speed
Time is of the essence, and we are respectful of yours
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods