PROFET BTS 442 E2
Smart Highside Power Switch
Features Product Summary
•
Overload protection
Overvoltage protection V 63 V
bb(AZ)
•
Current limitation
V 4.5 ... 42 V
Operating voltage bb(on)
•
Short-circuit protection
On-state resistance R 18
• ON mΩ
Thermal shutdown
•
Overvoltage protection (including load dump)
Load current (ISO) I 21 A
L(ISO)
•
Fast demagnetization of inductive loads
Current limitation IL(SCr) 70 A
1
• )
Reverse battery protection
•
Undervoltage and overvoltage shutdown with
TO-220AB/5
auto-restart and hysteresis
•
Open drain diagnostic output
•
Open load detection in ON-state 5
•
CMOS compatible input
5
5
2)
•
Loss of ground and loss of V protection
bb
1 1
1
•
Electrostatic discharge (ESD) protection
SMD
Straight leads Standard
Application
•
µC compatible power switch with diagnostic feedback for 12 V and 24 V DC grounded loads
•
All types of resistive, inductive and capacitve loads
•
Replaces electromechanical relays and discrete circuits
General Description
N channel vertical power FET with charge pump, ground referenced CMOS compatible input and diagnostic
feedback, integrated in Smart SIPMOS chip on chip technology. Fully protected by embedded protection
functions.
+ V
R
bb
bb
3
Voltage
Overvoltage Current Gate
source
protection limit protection
V
Logic
OUT
Charge pump Limit for
Voltage
unclamped
5
sensor Level shifter
Temperature
ind. loads
sensor
Rectifier
IN
2
Open load
Load
Logic
ESD detection
4
ST
Short circuit
detection
PROFET
GND
1
Load GND
Signal GND
1)
No external components required, reverse load current limited by connected load.
2)
Additional external diode required for charged inductive loads
Infineon Technologies AG 1 22.03.99
®
PROFET BTS 442 E2
Pin Symbol Function
1 GND - Logic ground
2 IN I Input, activates the power switch in case of logical high signal
3V + Positive power supply voltage,
bb
the tab is shorted to this pin
4 ST S Diagnostic feedback, low on failure
5 OUT O Output to the load
(Load, L)
Maximum Ratings at Tj = 25 °C unless otherwise specified
Parameter Symbol Values Unit
Supply voltage (overvoltage protection see page 3) V 63 V
bb
3)
Load dump protection V = U + V , U = 13.5 V V 80 V
LoadDump A s A Load dump
R = 2 Ω, R = 1.1 Ω, t = 200 ms, IN= low or high
I L d
Load current (Short-circuit current, see page 4) I self-limited A
L
Operating temperature range T -40 ...+150 °C
j
Storage temperature range T -55 ...+150
stg
Power dissipation (DC) P 167 W
tot
Inductive load switch-off energy dissipation,
single pulse T=150 °C: E 2.1 J
j AS
Electrostatic discharge capability (ESD) V 2.0 kV
ESD
(Human Body Model)
Input voltage (DC) V -0.5 ... +6 V
IN
Current through input pin (DC) I ±5.0 mA
IN
Current through status pin (DC) I ±5.0
ST
see internal circuit diagrams page 6...
Thermal resistance chip - case: R ≤ 0.75 K/W
thJC
≤ 75
junction - ambient (free air): R
thJA
4)
SMD version, device on pcb : ≤ tbd
3)
V is setup without the DUT connected to the generator per ISO 7637-1 and DIN 40839
Load dump
2
4)
Device on 50mm*50mm*1.5mm epoxy PCB FR4 with 6cm (one layer, 70µm thick) copper area for V
bb
connection. PCB is vertical without blown air.
Infineon Technologies AG 2 22.03.99
®
PROFET BTS 442 E2
Electrical Characteristics
Parameter and Conditions Symbol Values Unit
at Tj = 25 °C, V = 12 V unless otherwise specified
bb min typ max
Load Switching Capabilities and Characteristics
On-state resistance (pin 3 to 5)
I = 5 A T=25 °C: R -- 15 18
L j ON mΩ
T=150 °C: 28 35
j
Nominal load current (pin 3 to 5) I 17 21 -- A
L(ISO)
ISO Proposal: V = 0.5 V, T = 85 °C
ON C
Output current (pin 5) while GND disconnected or I -- -- 1 mA
L(GNDhigh)
GND pulled up, V = 0, see diagram page 7,
IN
T =-40...+150°C
j
Turn-on time to 90% V : t 100 -- 350 µs
OUT on
Turn-off time to 10% V : t 10 -- 130
OUT off
R = 12 Ω, T =-40...+150°C
L j
Slew rate on dV /dt 0.2 -- 2 V/µs
on
10 to 30% V , R = 12 Ω, T =-40...+150°C
OUT L j
Slew rate off -dV/dt 0.4 -- 5 V/µs
off
70 to 40% V , R = 12 Ω, T =-40...+150°C
OUT L j
Operating Parameters
5)
Operating voltage T =-40...+150°C: V 4.5 -- 42 V
j bb(on)
Undervoltage shutdown T =-40...+150°C: V 2.4 -- 4.5 V
j bb(under)
Undervoltage restart T =-40...+150°C: V -- -- 4.5 V
j bb(u rst)
Undervoltage restart of charge pump V -- 6.5 7.5 V
bb(ucp)
see diagram page 12 T =-40...+150°C:
j
Undervoltage hysteresis ∆V -- 0.2 -- V
bb(under)
∆V = V - V
bb(under) bb(u rst) bb(under)
Overvoltage shutdown T =-40...+150°C: V 42 -- 52 V
j bb(over)
Overvoltage restart T =-40...+150°C: V 42 -- -- V
j bb(o rst)
Overvoltage hysteresis T =-40...+150°C: ∆V -- 0.2 -- V
j bb(over)
6)
Overvoltage protection T =-40°C: V 60 -- -- V
j bb(AZ)
63 67
I =40 mA T =25...+150°C:
bb j
Standby current (pin 3) T =-40...+25°C: I -- 12 25 µA
j bb(off)
V =0 T =150°C: -- 18 60
IN j
I -- 6 -- µA
Leakage output current (included in I ) L(off)
bb(off)
VIN=0
7)
Operating current (Pin 1) , V =5 V I -- 1.1 -- mA
IN GND
5)
At supply voltage increase up to V = 6.5 V typ without charge pump, V ≈V - 2 V
bb OUT bb
6)
see also V in table of protection functions and circuit diagram page 7. Meassured without load.
ON(CL)
7)
Add I , if I > 0, add I , if V >5.5 V
ST ST IN IN
Infineon Technologies AG 3 22.03.99
®
PROFET BTS 442 E2
Parameter and Conditions Symbol Values Unit
at Tj = 25 °C, V = 12 V unless otherwise specified
bb
min typ max
Protection Functions
8)
Initial peak short circuit current limit (pin 3 to 5) , I
L(SCp)
( max 400 µs if V > V )
ON ON(SC)
=-40°C: -- -- 140 A
Tj
=25°C: -- 95 --
Tj
=+150°C: 45 -- --
Tj
Repetitive short circuit current limit I
L(SCr)
T = T (see timing diagrams, page 10) 30 70 -- A
j jt
Short circuit shutdown delay after input pos. slope
V > V , T =-40..+150°C: t
ON ON(SC) j d(SC)
80 -- 400 µs
min value valid only, if input "low" time exceeds 30 µs
Output clamp (inductive load switch off)
at V = V - V , I = 30 mA V -- 58 -- V
OUT bb ON(CL) L ON(CL)
Short circuit shutdown detection voltage
(pin 3 to 5) V -- 8.3 -- V
ON(SC)
Thermal overload trip temperature T 150 -- -- °C
jt
Thermal hysteresis ∆T -- 10 -- K
jt
9)
Inductive load switch-off energy dissipation , E -- -- 2.1 J
AS
T = 150 °C, single pulse V = 12 V: E 1.7
j Start bb Load12
1.2
V = 24 V: E
bb Load24
10)
Reverse battery (pin 3 to 1) -V -- -- 32 V
bb
Integrated resistor in V line R -- 120 -- Ω
bb bb
Diagnostic Characteristics
Open load detection current T =-40 °C: I 2 -- 1900 mA
j L (OL)
(on-condition) T =25..150°C: 2 -- 1500
j
8)
Short circuit current limit for max. duration of t =400 µs, prior to shutdown
d(SC) max
9)
While demagnetizing load inductance, dissipated energy in PROFET is E = V * i (t) dt, approx.
AS ON(CL) L
∫
V
2 ON(CL)
1
E = / * L * I * ( ), see diagram page 8
AS
2
L V - V
ON(CL) bb
10)
Reverse load current (through intrinsic drain-source diode) is normally limited by the connected load.
Reverse current I of ≈ 0.3 A at V = -32 V through the logic heats up the device. Time allowed under
GND bb
these condition is dependent on the size of the heatsink. Reverse I can be reduced by an additional
GND
external GND-resistor (150 Ω). Input and Status currents have to be limited (see max. ratings page 2 and
circuit page 7).
Infineon Technologies AG 4 22.03.99
®
PROFET BTS 442 E2
Parameter and Conditions Symbol Values Unit
at Tj = 25 °C, V = 12 V unless otherwise specified
bb
min typ max
11)
Input and Status Feedback
Input turn-on threshold voltage V 1.5 -- 2.4 V
IN(T+)
T =-40..+150°C:
j
Input turn-off threshold voltage V 1.0 -- -- V
IN(T-)
T =-40..+150°C:
j
Input threshold hysteresis ∆ V -- 0.5 -- V
IN(T)
Off state input current (pin 2), V = 0.4 V I 1-- 30 µA
IN IN(off)
On state input current (pin 2), V = 3.5 V I 10 25 50 µA
IN IN(on)
Status invalid after positive input slope t 80 200 400 µs
d(ST SC)
(short circuit) T =-40 ... +150°C:
j
Status invalid after positive input slope t 350 -- 1600 µs
d(ST)
(open load) T =-40 ... +150°C:
j
Status output (open drain)
Zener limit voltage T =-40...+150°C, I = +1.6 mA: V 5.4 6.1 -- V
j ST ST(high)
ST low voltage T =-40...+150°C, I = +1.6 mA: V -- -- 0.4
j ST ST(low)
11)
If a ground resistor R is used, add the voltage drop across this resistor.
GND
Infineon Technologies AG 5 22.03.99
®
PROFET BTS 442 E2
Truth Table
Input- Output Status
level level 442 442
D2 E2
Normal L L H H
H
operation H H H
12
)
Open load L H H
H
H L L
Short circuit L L H H
to GND H L L L
H
Short circuit L H H
13) 13)
to V H H H (L ) H (L )
bb
Overtem- L L L L
L
perature H L L
14)
Under- L L L H
14)
voltage H L L H
Overvoltage L L L H
H L L H
L = "Low" Level
H = "High" Level
Terms
Status output
+5V
I
bb
3
I
IN
V R
bb ST(ON)
IN
ST
2 I
V
L
ON
OUT
PROFET
I
5
ST
ESD-
ST
4
ZD
V GND
V GND
IN ST
V 1
I
bb
V
GND
OUT
ESD-Zener diode: 6.1 V typ., max 5 mA;
R
GND
R < 250 Ω at 1.6 mA, ESD zener diodes are not
ST(ON)
to be used as voltage clamp at DC conditions.
Operation in this mode may result in a drift of the zener
Input circuit (ESD protection)
voltage (increase of up to 1 V).
R
I
IN
ESD-
ZD ZD
I1 I2
I
I
GND
ZD 6.1 V typ., ESD zener diodes are not to be used
I1
as voltage clamp at DC conditions. Operation in this
mode may result in a drift of the zener voltage
(increase of up to 1 V).
12)
Power Transistor off, high impedance
13)
Low resistance short V to output may be detected by no-load-detection
bb
14)
No current sink capability during undervoltage shutdown
Infineon Technologies AG 6 22.03.99
®
PROFET BTS 442 E2
Short Circuit detection Open-load detection
Fault Condition: V > 8.3 V typ.; IN high ON-state diagnostic condition: V < R * I ; IN
ON ON ON L(OL)
high
+ V
bb
+ V
bb
V
ON
V
ON
ON
OUT
Short circuit
Logic
OUT
detection
unit
Open load
Logic
detection
unit
Inductive and overvoltage output clamp
+ V
bb
V
Z
GND disconnect
V
ON
3
OUT
V
bb
IN
GND
2
OUT
PROFET
5
V clamped to 58 V typ.
ON
ST
4
GND
Overvolt. and reverse batt. protection
V V V 1
V
bb IN ST
GND
+ V
bb
R
Any kind of load. In case of Input=high is V ≈ V - V .
bb OUT IN IN(T+)
V
Z
Due to V >0, no V = low signal available.
R GND ST
IN
IN
GND disconnect with GND pull up
Logic
V
OUT
ST
R
3
ST
GND
PROFET
V
bb
IN
2
R
GND
OUT
PROFET
Signal GND 5
ST
R = 120 Ω typ., V +R *40 mA = 67 V typ., add
4
bb Z bb
GND
R , R , R for extended protection
GND IN ST
1
V V
V
V IN ST
GND
bb
Any kind of load. If V > V - V device stays off
GND IN IN(T+)
Due to V >0, no V = low signal available.
GND ST
Infineon Technologies AG 7 22.03.99
®
PROFET BTS 442 E2
V disconnect with charged inductive Inductive Load switch-off energy
bb
load dissipation
E
bb
3
E
AS
V
high
bb
E
IN
Load
2
V
bb
IN
OUT
PROFET
5
OUT
PROFET
ST
4
=
GND
ST E
L
1 GND
V E
R
bb
Energy dissipated in PROFET E = E + E - E .
AS bb L R
3
2
1
E < E , E = / * L * I
Load L L 2
L
V
high
bb
IN
2
OUT
PROFET
5
ST
4
GND
1
V
bb
Infineon Technologies AG 8 22.03.99
®
PROFET BTS 442 E2
Options Overview
all versions: High-side switch, Input protection, ESD protection, load dump and
reverse battery protection , protection against loss of ground
Type BTS 442D2 442E2
Logic version
D E
Overtemperature protection
15 16
) )
T >150 °C, latch function X
j
X
T >150 °C, with auto-restart on cooling
j
Short-circuit to GND protection
15)
switches off when V >8.3 V typ. X X
ON
(when first turned on after approx. 200 µs)
Open load detection
in OFF-state with sensing current 30 µA typ.
in ON-state with sensing voltage drop across
X X
power transistor
Undervoltage shutdown with auto restart
X X
Overvoltage shutdown with auto restart
X X
Status feedback for
overtemperature X X
short circuit to GND X X
17) 17)
- -
short to V
bb
open load X X
undervoltage X -
overvoltage X -
Status output type
CMOS X
X
Open drain
Output negative voltage transient limit
(fast inductive load switch off)
to V - V
bb ON(CL)
X X
Load current limit
high level (can handle loads with high inrush currents) X X
medium level
low level (better protection of application)
15)
Latch except when V -V < V after shutdown. In most cases V = 0 V after shutdown (V ≠
bb OUT ON(SC) OUT OUT
0 V only if forced externally). So the device remains latched unless V < V (see page 4). No latch
bb ON(SC)
between turn on and t .
d(SC)
16)
With latch function. Reseted by a) Input low, b) Undervoltage, c) Overvoltage
17)
Low resistance short V to output may be detected by no-load-detection
bb
Infineon Technologies AG 9 22.03.99
®
PROFET BTS 442 E2
Timing diagrams
Figure 1a: V turn on:
bb
Figure 2b: Switching an inductive load
IN
IN
t
d(bb IN)
V
bb
d(ST)
t
ST
*)
V
OUT V
OUT
A
ST open drain
I
L
I
L(OL)
t
A
t
in case of too early V =high the device may not turn on (curve A)
IN
t approx. 150 µs
d(bb IN)
*) if the time constant of load is too large, open-load-status may
occur
Figure 2a: Switching a lamp,
Figure 3a: Turn on into short circuit,
IN
IN
ST
ST
V
OUT
V
OUT
t
d(SC)
I
L
I
L
t
t
t approx. 200µs if V - V > 8.3 V typ.
d(SC) bb OUT
Infineon Technologies AG 10 22.03.99
®
PROFET BTS 442 E2
Figure 3b: Turn on into overload, Figure 4a: Overtemperature:
Reset if T
Frequently asked questions
What makes Elite.Parts unique?
What kind of warranty will the BTS442E2 have?
Which carriers does Elite.Parts work with?
Will Elite.Parts sell to me even though I live outside the USA?
I have a preferred payment method. Will Elite.Parts accept it?
Manufacturers





What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods