Elite.Parts chervon right Manufacturers chervon right H chervon right HOERBIGER ORIGA chervon right PD 40664
About product Datasheet FAQ

HOERBIGER ORIGA PD 40664

Image of HOERBIGER ORIGA PD 40664

Description

HOERBIGER ORIGA PD 40664 - 5/2 Double Solenoid

Part Number

PD 40664

Price

Request Quote

Manufacturer

HOERBIGER ORIGA

Lead Time

Request Quote

Category

PRODUCTS - P

Datasheet

pdf file

ParkerOrig-280238824a.pdf

1920 KiB

Extracted Text

aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Valves Catalog 0952 ORIGA Catalog 0952 Valves Warning, Offer of Sale ! WARNING FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE. This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investigation by users h aving technical expertise. It is important that you analyze all aspects of your application including consequences of any failure, and review the information concerning the product or system in the current product catalog. Due to the variety of operating conditions and applications for these products or systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products and systems and assuring that all performance, safety and warning requirements of the application are met. The products described herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change by Parker Hannifin Corporation and its subsidiaries at any time without notice. Offer of Sale The items described in this document are hereby offered for sale by Parker Hannifin Corporation, its subsidiaries or its authorized distributors. This offer and its acceptance are governed by the provisions stated on the separate page of this document entitled “Offer of Sale”. © Copyright 2008 Parker Hannifin Corporation. All Rights Reserved Parker Hannifin Corporation Parker-Origa Glendale Heights, Illinois ORIGA www.parkeroriga.com Catalog 0952 Valves Index Table ofContents Solenoid Valves - 3/2-way 1/8.......................................................................... page 2-3 - 3/2-way 1/4.......................................................................... page 4-5 - 3/2-way 1/2.......................................................................... page 6-7 - 5/2-way 1/8, 1/4, 1/2............................................................ page 8-11 Air Pilot Valves - 5/2-way 1/8.......................................................................... page 12 - 5/2-way 1/4.......................................................................... page 13 Hand Lever Valves - 3/2 & 5/2-way 1/8 ................................................................ page 14-15 - 3/2 & 5/2-way 1/4 ................................................................ page 16-17 - 3/2 & 5/2-way 1/2 ................................................................ page 18-19 - 5/3-way 1/8.......................................................................... page 20-21 - 5/3-way 1/4.......................................................................... page 22-23 - 5/3-way 1/2.......................................................................... page 24 Interference Sensing Module - 5/2-way................................................................................. page 25 ISO Valves- Size 1 ............................................................................. page 26-27 - Size 2 ................................................................................... page 28-29 - Size 3 ................................................................................... page 30-31 - Order Instructions ................................................................ page 32-33 NAMUR Valves - 5/2-way 1/8.......................................................................... page 34-35 - 5/2-way 1/4.......................................................................... page 36-37 Two-Hand Safety Valves - 5/2-way 1/8.......................................................................... page 38 - 5/2-way 1/4.......................................................................... page 39 Oscillating Valves - 5/2-way 1/4.......................................................................... page 40-41 Foot Pedal Valves - 3/2-way 1/4.......................................................................... page 42-43 - 5/2-way 1/4.......................................................................... page 44-45 Valve Mountings - Barstock Manifold 1/8 .......................................................... page 46 - Barstock Manifold 1/4 .......................................................... page 47 - ISO Subbase (1, 2, 3) .......................................................... page 48-49 Spare Parts/Accessories ................................................................... page 50 Safety Guide ...................................................................................... page 54-55 Offer of Sale ...................................................................................... page 56 Parker Hannifin Corporation 1 Parker-Origa Glendale Heights, Illinois ORIGA www.parkeroriga.com 83251 ORIC0C Body Ported Valves 10/2/03 9:17 AM Page 1 Catalog 0952 Valves Characteristics 3/2-Way Valve, 1/8 Inch Characteristics to VDI 3290 Pressures quoted as gauge pressure 3/2-Way Valve Characteristics Symbol Unit Description 1/8 General Features Type Spool valve Mounting 2 screws M6 (M3) Actuation: Solenoid Tube connection Thread - Single Solenoid - Double Solenoid Port size NPT (G) 1/8 Weight (mass) lbs. (kg) .54 (0.247) Single solenoid .84 (0.382) Double solenoid Installation In any position Note: Ambient ϑ °F (°C) 14 (-10) min temperature range ϑ 140 (+60) When using below freezing max point it is necessary to Medium ϑ °F (°C) 14 (-10) min consult factory. temperature range ϑ 158 (+70) max Medium Filtered compressed air 1) Lubrication With or without oil mist lubrication Pneumatic Characteristics Nominal pressure p psi (bar) 87 (6) n Operating pressure Single solenoid range p psi (bar) 29 (2) min p 145 (10) max Double solenoid p psi (bar) 22 (1.5) min p 145 (10) max Nominal flow Q Cv (I/min) .45 (450) N Actuation Electrical Pilot operated Voltage AC DC Nominal voltage* Standard version U V 220 24 n Initial power consumption Standard version VA (W) 8.5 2.5 Continuous consumption Standard version VA (W) 6.0 2.5 Duty cycle ED % Continuous Duty Electrical protection IP65 to DIN 40050 (with plug) Insulating material VDE 0580 Connection Plug to DIN 43650 form B 1) We recommend the use of mineral oil type VG32 to ISO 3448 1 Parker Hannifin Corporation 2 Parker-Origa Glendale Heights, Illinois ORIGA www.parkeroriga.com 83251 ORIC0C Body Ported Valves 10/2/03 9:17 AM Page 2 Catalog 0952 Valves Dimensions & Ordering Information 3/2-Way Valve, 1/8 Inch Dimensions (mm) 22 (10) 12 p st 3(1) 2 1(3) p st (12) 10 16,6 5,5 5 15,5 40 63 Version 1/8 Metric Version NPT Version Actuation Symbol Type Number Order Number Type Number Order Number 2 12 10 3/2 Single Solenoid/Spring Return S9 381RF-1/8-NG-.. PA 10297-..33 S9 381RF-1/8U-NG-.. PD 43295-..33 1 3 2 10 12 3/2 Single Solenoid/Spring Return S9 381RF-1/8-NO-.. PA 10298-..33 S9 381RF-1/8U-NO-.. PD 45459-..33 1 3 2 12 10 3/2 Double Solenoid S9 381-1/8-.. PA 10299-..33 S9 381-1/8U-.. PD 45460-..33 1 3 Voltage Range Nominal Secondary Coil Number Order Code 12 vDC -- KZ 3674 01 24 vDC 60 50/60Hz KZ 3673 02 110 50/60Hz 48 vDC KZ 3669 57 220 50/60Hz 110 vDC KZ 3672 61 24 50/60Hz -- KZ 3675 51 • Other voltages available. Contact factory. • Explosion proof coils available. Contact factory. • UL/CSA rated coils available. Contact factory. 2 Parker Hannifin Corporation 3 Parker-Origa Glendale Heights, Illinois ORIGA www.parkeroriga.com 8 5 3,2 5,6 ca.122 56 110 69,5 15,5 37 24 18 33,5 10,5 M5 G1/8 G1/8 42,5 36 24,5 ca.190 83251 ORIC0C Body Ported Valves 10/2/03 9:17 AM Page 3 Catalog 0952 Valves Characteristics 3/2-Way Valve, 1/4 Inch Characteristics to VDI 3290 Pressures quoted as gauge pressure 3/2-Way Valve Characteristics Symbol Unit Description 1/4 General Features Type Spool valve Mounting 2 screws M6 (M4) Actuation: Solenoid Tube connection Thread - Single Solenoid - Double Solenoid Port size NPT (G) 1/4 Weight (mass) lbs. (kg) 1.1 (0.5) Single solenoid 1.32 (0.6) Double solenoid Installation In any position Note: Ambient ϑ °F (°C) 14 (-10) min temperature range ϑ 140 (+60) When using below freezing max point it is necessary to Medium ϑ °F (°C) 14 (-10) min consult factory. temperature range ϑ 158 (+70) max Medium Filtered compressed air 1) Lubrication With or without oil mist lubrication Pneumatic Characteristics Nominal pressure p psi (bar) 87 (6) n Operating pressure Single solenoid range p psi (bar) 29 (2) min p 145 (10) max Double solenoid p psi (bar) 22 (1.5) min p 145 (10) max Nominal flow Q Cv (I/min) 1.3 (1300) N Actuation Electrical Pilot operated Voltage AC DC Nominal voltage* Standard version U V 220 24 n Initial power consumption Standard version VA (W) 8.5 2.5 Continuous consumption Standard version VA (W) 6.0 2.5 Duty cycle ED % Continuous Duty Electrical protection IP65 to DIN 40050 (with plug) Insulating material VDE 0580 Connection Plug to DIN 43650 form B 1) We recommend the use of mineral oil type VG32 to ISO 3448 3 Parker Hannifin Corporation 4 Parker-Origa Glendale Heights, Illinois ORIGA www.parkeroriga.com 83251 ORIC0C Body Ported Valves 10/2/03 9:17 AM Page 4 Catalog 0952 Valves Dimensions & Ordering Information 3/2-Way Valve, 1/4 Inch Dimensions (mm) 32 22 *** 12 (10) 25 p st 3(1) 2 1(3) p st (12) 10 4,5 6,5 6 15,5 52 63 Version 1/4 Metric Version NPT Version Actuation Symbol Type Number Order Number Type Number Order Number 2 12 10 3/2 Single Solenoid/Spring Return S9 381RF-1/4-NG-.. PA 12716-..33 S9 381RF-1/4U-NG-.. PD 45461-..33 1 3 2 10 12 3/2 Single Solenoid/Spring Return S9 381RF-1/4-NO-.. PA 12717-..33 S9 381RF-1/4U-NO-.. PD 45462-..33 1 3 2 12 10 3/2 Double Solenoid S9 381-1/4-.. PA 12718-..33 S9 381-1/4U-.. PD 45463-..33 1 3 Voltage Range Nominal Secondary Coil Number Order Code 12 vDC -- KZ 3674 01 24 vDC 60 50/60Hz KZ 3673 02 110 50/60Hz 48 vDC KZ 3669 57 220 50/60Hz 110 vDC KZ 3672 61 24 50/60Hz -- KZ 3675 51 • Other voltages available. Contact factory. • Explosion proof coils available. Contact factory. • UL/CSA rated coils available. Contact factory. 4 Parker Hannifin Corporation 5 Parker-Origa Glendale Heights, Illinois ORIGA www.parkeroriga.com ca. 209 ca.137 62 126 20 84 47 28,5 22 G 1/4 o 4,2 G 1/8 52 o 7,5 44 30 11 5,5 M5 10 41 83251 ORIC0C Body Ported Valves 10/2/03 9:17 AM Page 5 Catalog 0952 Valves Characteristics 3/2-Way Valve, 1/2 Inch Characteristics to VDI 3290 Pressures quoted as gauge pressure 3/2-Way Valve Characteristics Symbol Unit Description 1/2 General Features Type Spool valve Mounting 2 screws M6 Actuation: Solenoid Tube connection Thread - Single Solenoid - Double Solenoid Port size NPT (G) 1/2 Weight (mass) lbs. (kg) 1.69 (0.77) Single solenoid 1.32 (0.60) Double solenoid Installation In any position Ambient ϑ °F (°C) 14 (-10) Note: min When using below freezing temperature range ϑ 140 (+60) max point it is necessary to Medium ϑ °F (°C) 14 (-10) min consult factory. temperature range ϑ 158 (+70) max Medium Filtered compressed air 1) Lubrication With or without oil mist lubrication Pneumatic Characteristics Nominal pressure p psi (bar) 87 (6) n Operating pressure Single solenoid range p psi (bar) 29 (2) min p 145 (10) max Double solenoid p psi (bar) 22 (1.5) min p 145 (10) max Nominal flow Q Cv (I/min) 3.5 (3500) N Actuation Electrical Pilot operated Voltage AC DC Nominal voltage* Standard version U V 220 24 n Initial power consumption Standard version VA (W) 11 4.8 Continuous consumption Standard version VA (W) 8.5 4.8 Duty cycle ED % Continuous Duty Electrical protection IP65 to DIN 40050 (with plug) Insulating material VDE 0580 Connection Plug to DIN 43650 form B 1) We recommend the use of mineral oil type VG32 to ISO 3448 5 Parker Hannifin Corporation 6 Parker-Origa Glendale Heights, Illinois ORIGA www.parkeroriga.com 83251 ORIC0C Body Ported Valves 10/2/03 9:17 AM Page 6 Catalog 0952 Valves Dimensions & Ordering Information 3/2-Way Valve, 1/2 Inch Dimensions (mm) 70 68 40 21 22 p st 12 3 2 1 10 p st 6,5 Version 1/2 Metric Version NPT Version Actuation Symbol Type Number Order Number Type Number Order Number 2 12 10 3/2 Single Solenoid/Spring Return S9 381RF-1/2-NG-.. PA 16412-..33 S9 381RF-1/2U-NG-.. PD 45464-..33 1 3 2 10 12 3/2 Single Solenoid/Spring Return S9 381RF-1/2-NO-.. PA 16413-..33 S9 381RF-1/2U-NO-.. PD 45465-..33 1 3 2 12 10 3/2 Double Solenoid S9 381-1/2-.. PA 16414-..33 S9 381-1/2U-.. PD 45466-..33 1 3 Voltage Range Nominal Secondary Coil Number Order Code 12 vDC -- KZ 3518 01 24 vDC 60 50/60Hz KZ 3519 02 110 50/60Hz 48 vDC KZ 3521 57 220 50/60Hz 110 vDC KZ 3522 61 • Other voltages available. Contact factory. • Explosion proof coils available. Contact factory. • UL/CSA rated coils available. Contact factory. 6 Parker Hannifin Corporation 7 Parker-Origa Glendale Heights, Illinois ORIGA www.parkeroriga.com 246 167 70 158 29 117 39 68 32 57 12,5 7 G1/8 G1/2 29 73 83251 ORIC0C Body Ported Valves 10/2/03 9:17 AM Page 7 Catalog 0952 Valves Characteristics 5/2-Way & 5/3-Way Valve, 1/8, 1/4, 1/2 Inch Features 5/2-Way Valve Type Spool Valve Mounting 2 Screws 5/3-Way Valve Port connection Threaded 1 1 1 Port size G/NPT /8 • /4 • /2 1/8 • 1/4 • 1/2 Installation In Any Position Ambient min 14°F (-10°C) Note: temperature range max 140°F (+60°C) When using below freezing Actuation: Solenoid point it is necessary to Medium min 14°F (-10°C) - Single Solenoid temperature range max 158°F (+70°C) consult factory. - Double Solenoid Medium Filtered Compressed Air 1) Lubrication With or Without Oil Mist Lubrication Pneumatic Characteristics Body 5/2 Position 5/3 Position Size Single Double Double 1/8 Minimum Pressure psi (bar) 29 (2) 22 (1.5) 29 (2) Maximum Pressure psi (bar) 145 (10) 145 (10) 145 (10) Flow Cv (l/min) 0.5 (500) 0.5 (500) 0.6 (600) Weight lbs. (kg) 0.62 (0.28) 0.91 (0.415) 0.94 (0.425) 1/4 Minimum Pressure psi (bar) 29 (2) 22 (1.5) 29 (2) Maximum Pressure psi (bar) 145 (10) 145 (10) 145 (10) Flow Cv (l/min) 1.3 (1300) 1.3 (1300) RFG,RFB:1.3(1300) RFE:1.0 (1000) Weight lbs. (kg) 1.32 (0.6) 1.54 (0.7) 1.54 (0.7) 1/2 Minimum Pressure psi (bar) 32 (2.2) 22 (1.5) 36 (2.5) Maximum Pressure psi (bar) 145 (10) 145 (10) 145 (10) Flow Cv (l/min) 3.5 (3500) 3.5 (3500) RFE:3.3 (3300) RFG:3.5 (3500) RFB:3.6 (3600) Weight lbs. (kg) 2.2 (1.0) 2.43 (1.1) 2.43 (1.1) Voltage AC DC Nominal Standard Version V 24, 110, 220 12, 24 Voltage Others Contact Factory Power Consumption Inrush Body Size: 1/8 • 1/4 Body Size: 1/2 AC DC AC DC 50 HZ 60 HZ 50 HZ 60 HZ 12 — — 2.8 W 10.4VA 10.4VA 4.5 W 24 8.5VA 8.5VA 2.5 W 10.4VA 10.4VA 4.5 W 110 8.5VA 8.5VA 2.7 W 10.4VA 10.4VA 5.5 W 220 8.5VA 8.5VA 3.5 W 10.4VA 10.4VA 4.9 W Holding Body Size: 1/8 • 1/4 Body Size: 1/2 AC DC AC DC 50 HZ 60 HZ 50 HZ 60 HZ 12 — — 2.8 W 8.5VA 8.5VA 4.5 W 24 6.0VA 6.0VA 2.5 W 8.5VA 8.5VA 4.5 W 110 6.0VA 4.9VA 2.7 W 8.2VA 6.6VA 5.5 W 220 6.0VA 4.9VA 3.5 W 8.5VA 6.9VA 4.9 W Duty cycle ED % Continuous Duty Electrical protection IP65 to DIN 40050 (with plug) Installing material VDE 0580 Connection Plug to DIN 43650 Form B 1) We recommend the use of mineral oil type VG32 to ISO 3448 7 Parker Hannifin Corporation 8 Parker-Origa Glendale Heights, Illinois ORIGA www.parkeroriga.com 83251 ORIC0C Body Ported Valves 10/2/03 9:18 AM Page 8 Catalog 0952 Valves Dimensions & Ordering Information 5/2-Way & 5/3-Way Valve, 1/8, 1/4, 1/2 Inch VERSION 1/8 Metric Version NPT Version Actuation Symbol Type Number Order Number Type Number Order Number 4 2 14 12 5/2 Single Solenoid/Spring Return S9 581RF-1/8-.. PA 10312-..33 S9 581RF-1/8 U-.. PD 40663-..33 5 13 4 2 14 12 5/2 Double Solenoid S9 581-1/8-.. PA 10313-..33 S9 581-1/8 U-.. PD 40664-..33 5 13 4 2 14 12 5/3 Double Solenoid/Center Blocked S9 581RFG-1/8-.. PA 10333-..33 S9 581RFG-1/8 U-.. PD 40736-..33 513 4 2 12 14 5/3 Double Solenoid/Center Exhaust S9 581RFE-1/8-.. PA 10334-..33 S9 581RFE-1/8 U-.. PD 40737-..33 5 13 4 2 14 12 5/3 Double Solenoid/Dual Center S9 581RFB-1/8-.. PA 10335-..33 S9 581RFB-1/8 U-.. PD 40738-..33 5 13 VERSION 1/4 Metric Version NPT Version Actuation Symbol Type Number Order Number Type Number Order Number 4 2 14 12 5/2 Single Solenoid/Spring Return S9 581RF-1/4-.. PA 12679-..33 S9 581RF-1/4 U-.. PD 40665-..33 5 13 4 2 12 14 5/2 Double Solenoid S9 581-1/4-.. PA 12680-..33 S9 581-1/4 U-.. PD 40666-..33 5 13 4 2 14 12 5/3 Double Solenoid/Center Blocked S9 581RFG-1/4-.. PA 12705-..33 S9 581RFG-1/4 U-.. PD 40739-..33 513 4 2 12 14 5/3 Double Solenoid/Center Exhaust S9 581RFE-1/4-.. PA 12706-..33 S9 581RFE-1/4 U-.. PD 40740-..33 5 13 4 2 14 12 5/3 Double Solenoid/Dual Center S9 581RFB-1/4-.. PA 12707-..33 S9 581RFB-1/4 U-.. PD 40741-..33 5 13 Voltage Range • Other voltages available. Contact factory. • Explosion proof coils available. Contact factory. Nominal Secondary Coil Number Order Code • UL/CSA rated coils available. Contact factory. 12 vDC -- KZ 3674 01 24 vDC 60 50/60Hz KZ 3673 02 110 50/60Hz 48 vDC KZ 3669 57 220 50/60Hz 110 vDC KZ 3672 61 24 50/60Hz -- KZ 3675 51 VERSION 1/2 Metric Version NPT Version Actuation Symbol Type Number Order Number Type Number Order Number 4 2 14 12 5/2 Single Solenoid/Spring Return S9 581RF-1/2-.. PA 16171-..33 S9 581RF-1/2U-.. PD 37950-..33 5 13 4 2 14 12 5/2 Double Solenoid S9 581-1/2-.. PA 16172-..33 S9 581-1/2U-.. PD 37951-..33 5 13 4 2 14 12 5/3 Double Solenoid/Center Blocked S9 581RFG-1/2-.. PA 16176-..33 S9 581RFG-1/2U-.. PD 37971-..33 513 4 2 12 14 5/3 Double Solenoid/Center Exhaust S9 581RFE-1/2-.. PA 16177-..33 S9 581RFE-1/2U-.. PD 37972-..33 5 13 4 2 14 12 5/3 Double Solenoid/Dual Center S9 581RFB-1/2-.. PA 16178-..33 S9 581RFB-1/2U-.. PD 37973-..33 5 13 • Other voltages available. Contact factory. Voltage Range • Explosion proof coils available. Contact factory. Nominal Secondary Coil Number Order Code • UL/CSA rated coils available. Contact factory. 12 vDC -- KZ 3518 01 24 vDC 60 50/60Hz KZ 3519 02 110 50/60Hz 48 vDC KZ 3521 57 220 50/60Hz 110 vDC KZ 3522 61 8 Parker Hannifin Corporation 9 Parker-Origa Glendale Heights, Illinois ORIGA www.parkeroriga.com 83251 ORIC0C Body Ported Valves 10/2/03 9:18 AM Page 9 Catalog 0952 Valves Dimensions 5/2-Way & 5/3-Way Valve, 1/8 & 1/4 Inch Sizes: 1/8 & 1/4 Y X 14 Z p st 5 ** 4 1 2 AH 3 p st 12 W * S *- Manual Override Push: Non-Locking R Push & Turn: Locking P A B C D E F G H J K L M N O P 8.19 5.51 5.04 3.44 2.19 0.94 1.32 0.71 2.20 0.61 2.13 0.96 1.67 0.22 2.48 1/8 208 140 128 87.5 55.5 24 33.5 18 56 15.5 54 24.5 42.5 5.5 63 9.09 6.26 5.83 4.17 2.64 1.16 1.61 0.87 2.44 0.79 2.60 1.18 2.05 0.26 2.48 1/4 231 159 148 106 67 29.5 41 22 62 20 66 30 52 6.5 63 R S T U W X Y Z AA AB AC AD AE AF AG 1.57 0.61 1/8 npt 1/8 npt 0.20 - - 0.87 0.65 0.31 0.20 M5 0.41 - - 0.13 0.22 1/8 40 15.5 G 1/8 G 1/8 5 - - 22 16.6 8 5 M5 10.5 - - 3.2 5.6 2.05 0.61 1/8 npt 1/4 npt 0.24 0.87 1.26 0.98 0.43 0.22 M5 0.39 - - - - - - 1/4 52 15.5 G 1/8 G 1/4 6 22 32 25 11 5.5 M5 10 - - - -- - - Dimensions: BOLD= Inches; STANDARD= mm 9 Parker Hannifin Corporation 10 Parker-Origa Glendale Heights, Illinois ORIGA www.parkeroriga.com A B J C D K E F H H O U AE T AG H N L M AA AB AC AD G 83251 ORIC0C Body Ported Valves 10/2/03 9:18 AM Page 10 Catalog 0952 Valves Dimensions 5/2-Way & 5/3-Way Valve, 1/2 Inch Size: 1/2 R Y P S X p st 14 5 ** 4 L 1 W 2 3 12 p st ** *- Manual Override Push: Non-Locking Push & Turn: Locking A B C D E F G H J K L M N O P 11.14 7.93 7.48 5.87 3.94 1.54 2.24 1.26 2.76 1.14 - - 0.49 2.87 0.28 2.68 1/2 283 201.5 190 149 100 39 57 32 70 29 - - 12.5 73 7 68 R S T U W X Y Z AA AB AC AD AE AF AG 2.76 0.83 1/8 npt 1/2 npt 0.26 0.87 1.57 - - - - - - - - - - - - - - - - 1/2 70 21 G 1/8 G 1/2 6.5 22 40 - - - - - - - - - - - - - - - - Dimensions: BOLD= Inches; STANDARD= mm 10 Parker Hannifin Corporation 11 Parker-Origa Glendale Heights, Illinois ORIGA www.parkeroriga.com A B J C K D E F H H G M T O U K H N 83251 ORIC0C Body Ported Valves 10/2/03 9:18 AM Page 11 Catalog 0952 Valves Characteristics & Dimensions 5/2-Way Valve, 1/8 Inch Characteristics to VDI 3290 Pressures quoted as gauge pressure 5/2-Way Valve Characteristics Symbol Unit Description 1/8 General Features Type Spool valve Mounting 2 screws M5 Actuation: Air Pilot Tube connection Thread - Single Air Pilot Port size NPT (G) 1/8 - Double Air Pilot Weight (mass) lbs. (kg) .35 (.160) Single Air Pilot .37 (.170) Double Air Pilot Installation In any position Ambient ϑ °F (°C) 14 (-10) Note: min temperature range ϑ 140 (+60) When using below freezing max point it is necessary to Medium ϑ °F (°C) 14 (-10) min consult factory. temperature range ϑ 158 (+70) max Medium Filtered compressed air 1) Lubrication With or without oil mist lubrication Pneumatic Characteristics Nominal pressure p psi (bar) 87 (6) n Operating pressure p psi (bar) 0 (0) min range p 145 (10) max Nominal flow Q Cv (I/min) .5 (500) N Actuation Air Pilot Direct Actuation Pressure p psi (bar) 30 (2) min Single Air Pilot Range p 145 (10) max p psi (bar) 22 (1.5) min Double Air Pilot p 145 (10) max 1) We recommend the use of mineral oil type VG32 to ISO 3448 Dimensions (mm)         only for type       Version 1/8 Metric Version NPT Version Actuation Type Number Order Number Type Number Order Number 5/2 Single Air Pilot/Spring Return S9 561RF-1/8 PA 10310 S9 561RF-1/8U PD 47240 5/2 Double Air Pilot S9 561-1/8 PA 10311 S9 561-1/8U PD 47239 11 Parker Hannifin Corporation 12 Parker-Origa Glendale Heights, Illinois ORIGA www.parkeroriga.com                 83251 ORIC0C Body Ported Valves 10/2/03 9:18 AM Page 12 Catalog 0952 Valves Characteristics & Dimensions 5/2-Way Valve, 1/4 Inch Characteristics to VDI 3290 Pressures quoted as gauge pressure 5/2-Way Valve Characteristics Symbol Unit Description 1/4 General Features Type Spool valve Mounting 2 screws M5 Actuation: Air Pilot Tube connection Thread - Single Air Pilot Port size NPT (G) 1/8 - Double Air Pilot Weight (mass) lbs. (kg) 1.08 (.49) Single Air Pilot 1.12 (.51) Double Air Pilot Installation In any position Ambient ϑ °F (°C) 14 (-10) min Note: temperature range ϑ 140 (+60) When using below freezing max point it is necessary to Medium ϑ °F (°C) 14 (-10) min consult factory. temperature range ϑ 158 (+70) max Medium Filtered compressed air 1) Lubrication With or without oil mist lubrication Pneumatic Characteristics Nominal pressure p psi (bar) 87 (6) n Operating pressure p psi (bar) 0 (0) min range p 145 (10) max Nominal flow Q Cv (I/min) 1.3 (1300) N Actuation Air Pilot Direct Actuation Pressure p psi (bar) 30 (2) min Single Air Pilot Range p 145 (10) max p psi (bar) 22 (1.5) min Double Air Pilot p 145 (10) max 1) We recommend the use of mineral oil type VG32 to ISO 3448 Dimensions (mm)          only for type   S9 561-1/4 S9 562-1/4   Version 1/4 Metric Version NPT Version Actuation Type Number Order Number Type Number Order Number 5/2 Single Air Pilot/Spring Return S9 561RF-1/4 PA 12676 S9 561RF-1/4U PD 47242 5/2 Double Air Pilot S9 561-1/4 PA 12677 S9 561-1/4U PD 47241 12 Parker Hannifin Corporation 13 Parker-Origa Glendale Heights, Illinois ORIGA www.parkeroriga.com                    19° 83251 ORIC0C Body Ported Valves 10/2/03 9:18 AM Page 13 Catalog 0952 Valves Characteristics & Dimensions 3/2-Way Valve, 1/8 Inch Characteristics to VDI 3290 Pressures quoted as gauge pressure 3/2-Way Valve Characteristics Symbol Unit Description 1/8 General Features Type Spool valve Mounting 2 screws M5 Actuation: Hand lever Tube connection Thread - Detent Port size NPT (G) 1/8 - Spring Return Weight (mass) lbs. (kg) .356 (.162) Installation In any position Ambient ϑ °F (°C) 14 (-10) Note: min temperature range ϑ 140 (+60) When using below freezing max point it is necessary to Medium ϑ °F (°C) 14 (-10) min consult factory. temperature range ϑ 158 (+70) max Medium Filtered compressed air 1) Lubrication With or without oil mist lubrication Pneumatic Characteristics Nominal pressure p psi (bar) 131 (6) n Operating pressure p psi (bar) 0 (0) min range p 145 (10) max Nominal flow Q Cv (I/min) 4.5 (450) N Actuation Manual control Direct Stroke in (mm) .177 (4.5) Actuation force F lbf (N) 1.57 (7) detent b 2.25 (10) spring 1) We recommend the use of mineral oil type VG32 to ISO 3448 Dimensions (mm) 94 29 7 20 12 3 2 1 10 22 5,5 5 40 Version 1/8 Metric Version NPT Version Actuation Type Number Order Number Type Number Order Number 3/2 Hand Lever/Detent S9 311-1/8 PA 10293 S9 311-1/8U PD 45467 3/2 Hand Lever/Spring Return S9 311RF-1/8 PA 10294 S9 311RF-1/8U PD 45468 13 Parker Hannifin Corporation 14 Parker-Origa Glendale Heights, Illinois ORIGA www.parkeroriga.com 77 37 31,5 18 41 11,5 G1/8 50 19° 83251 ORIC0C Body Ported Valves 10/2/03 9:18 AM Page 14 Catalog 0952 Valves Characteristics & Dimensions 5/2-Way Valve, 1/8 Inch Characteristics to VDI 3290 Pressures quoted as gauge pressure 5/2-Way Valve Characteristics Symbol Unit Description 1/8 General Features Type Spool valve Mounting 2 screws M5 Actuation: Hand lever Tube connection Thread - Detent - Spring Return Port size NPT (G) 1/8 Weight (mass) lbs. (kg) .429 (.195) Installation In any position Ambient ϑ °F (°C) 14 (-10) Note: min When using below freezing temperature range ϑ 140 (+60) max point it is necessary to Medium ϑ °F (°C) 14 (-10) min consult factory. temperature range ϑ 158 (+70) max Medium Filtered compressed air 1) Lubrication With or without oil mist lubrication Pneumatic Characteristics Nominal pressure p psi (bar) 87 (6) n Operating pressure p psi (bar) 0 (0) min range p 145 (10) max Nominal flow Q Cv (I/min) .5 (500) N Actuation Manual control Direct Stroke in (mm) .177 (4.5) Actuation force F lbf (N) 1.57 (7) detent b 2.25 (10) spring 1) We recommend the use of mineral oil type VG32 to ISO 3448 Dimensions (mm) 94 28 20 7 14 5 4 1 2 3 12 5,5 22 5 40 Version 1/8 Metric Version NPT Version Actuation Type Number Order Number Type Number Order Number 5/2 Hand Lever/Detent S9 511-1/8 PA 10308 S9 511-1/8U PD 45469 5/2 Hand Lever/Spring Return S9 511RF-1/8 PA 10309 S9 511RF-1/8U PD 45470 14 Parker Hannifin Corporation 15 Parker-Origa Glendale Heights, Illinois ORIGA www.parkeroriga.com 95 55,5 31 18 18 41 11,5 G1/8 18 50 18° 83251 ORIC0C Body Ported Valves 10/2/03 9:18 AM Page 15 Catalog 0952 Valves Characteristics & Dimensions 3/2-Way Valve, 1/4 Inch Characteristics to VDI 3290 Pressures quoted as gauge pressure 3/2-Way Valve Characteristics Symbol Unit Description 1/4 General Features Type Spool valve Mounting 2 screws M6 Actuation: Hand lever Tube connection Thread - Detent Port size NPT (G) 1/4 - Spring Return - Safety Detent Weight (mass) lbs. (kg) .81 (.37) Installation In any position Ambient ϑ °F (°C) 14 (-10) Note: min temperature range ϑ 140 (+60) When using below freezing max point it is necessary to Medium ϑ °F (°C) 14 (-10) min consult factory. temperature range ϑ 158 (+70) max Medium Filtered compressed air 1) Lubrication With or without oil mist lubrication Pneumatic Characteristics Nominal pressure p psi (bar) 87 (6) n Operating pressure p psi (bar) 0 (0) min range p 145 (10) max Nominal flow Q Cv (I/min) 1.3 (1300) N Actuation Manual control Direct Stroke in (mm) .256 (6.5) Actuation force F lbf (N) 2.25 (10) detent & safety detent b 3.37 (15) spring 1) We recommend the use of mineral oil type VG32 to ISO 3448 Dimensions (mm) 120 44 25 12 12 3 2 1 10 32 6,5 6 52 Version 1/4 Metric Version NPT Version Actuation Type Number Order Number Type Number Order Number 3/2 Hand Lever/Detent S9 311-1/4 PA 12708 S9 311-1/4U PD 45477 3/2 Hand Lever/Spring Return S9 311RF-1/4 PA 12709 S9 311RF-1/4U PD 45478 3/2 Hand Lever/Detent (safety) S9 311S-1/4 PA 12710 S9 311RF-1/4U PD 45479 15 Parker Hannifin Corporation 16 Parker-Origa Glendale Heights, Illinois ORIGA www.parkeroriga.com 98 47 42,5 22 55 17 G1/4 66 18° 83251 ORIC0C Body Ported Valves 10/2/03 9:18 AM Page 16 Catalog 0952 Valves Characteristics & Dimensions 5/2-Way Valve, 1/4 Inch Characteristics to VDI 3290 Pressures quoted as gauge pressure 5/2-Way Valve Characteristics Symbol Unit Description 1/4 General Features Type Spool valve Mounting 2 screws M6 Actuation: Hand lever Tube connection Thread - Detent Port size NPT (G) 1/4 - Spring Return - Safety Detent Weight (mass) lbs. (kg) 1.14 (.52) Installation In any position Ambient ϑ °F (°C) 14 (-10) Note: min When using below freezing temperature range ϑ 140 (+60) max point it is necessary to Medium ϑ °F (°C) 14 (-10) min consult factory. temperature range ϑ 158 (+70) max Medium Filtered compressed air 1) Lubrication With or without oil mist lubrication Pneumatic Characteristics Nominal pressure p psi (bar) 87 (6) n Operating pressure p psi (bar) 0 (0) min range p 145 (10) max Nominal flow Q Cv (I/min) 1.3 (1300) N Actuation Manual control Direct Stroke in (mm) .256 (6.5) Actuation force F lbf (N) 2.25 (10) detent b 3.37 (15) spring 1) We recommend the use of mineral oil type VG32 to ISO 3448 Dimensions (mm) 120 44 25 12 14 5 4 1 2 3 12 6,5 32 6 52 Version 1/4 Metric Version NPT Version Actuation Type Number Order Number Type Number Order Number 5/2 Hand Lever/Detent S9 511-1/4 PA 12671 S9 511-1/4U PD 45480 5/2 Hand Lever/Spring Return S9 511RF-1/4 PA 12672 S9 511RF-1/4U PD 45481 5/2 Hand Lever/Detent (safety) S9 511S-1/4 PA 12673 S9 511S-1/4U PD 45482 16 Parker Hannifin Corporation 17 Parker-Origa Glendale Heights, Illinois ORIGA www.parkeroriga.com 120 67 43,5 22 22 55 G1/4 17 22 66 10° 83251 ORIC0C Body Ported Valves 10/2/03 9:18 AM Page 17 Catalog 0952 Valves Characteristics & Dimensions 3/2-Way Valve, 1/2 Inch Characteristics to VDI 3290 Pressures quoted as gauge pressure 3/2-Way Valve Characteristics Symbol Unit Description 1/2 General Features Type Spool valve Mounting 2 screws M6 Actuation: Hand lever Tube connection Thread - Detent Port size NPT (G) 1/2 - Spring Return Weight (mass) lbs. (kg) 1.98 (.9) Installation In any position Ambient ϑ °F (°C) 14 (-10) Note: min When using below freezing temperature range ϑ 140 (+60) max point it is necessary to Medium ϑ °F (°C) 14 (-10) min consult factory. temperature range ϑ 158 (+70) max Medium Filtered compressed air 1) Lubrication With or without oil mist lubrication Pneumatic Characteristics Nominal pressure p psi (bar) 87 (6) n Operating pressure p psi (bar) 0 (0) min range p 145 (10) max Nominal flow Q Cv (I/min) 3.5 (3500) N Actuation Manual control Direct Stroke in (mm) .370 (9.4) Actuation force F lbf (N) 3.37 (15) detent b 8.99 (40) spring 1) We recommend the use of mineral oil type VG32 to ISO 3448 Dimensions (mm) 57 34 17 12 1 2 3 10 7 40 6,5 151 70 Version 1/2 Metric Version NPT Version Actuation Type Number Order Number Type Number Order Number 3/2 Hand Lever/Detent S9 311-1/2 PA 16404 S9 311-1/2U PD 45492 3/2 Hand Lever/Spring Return S9 311RF-1/2 PA 16405 S9 311RF-1/2U PD 45493 17 Parker Hannifin Corporation 18 Parker-Origa Glendale Heights, Illinois ORIGA www.parkeroriga.com 135 68 57 32 75 25 G1/2 91 20° 83251 ORIC0C Body Ported Valves 10/2/03 9:18 AM Page 18 Catalog 0952 Valves Characteristics & Dimensions 5/2-Way Valve, 1/2 Inch Characteristics to VDI 3290 Pressures quoted as gauge pressure 5/2-Way Valve Characteristics Symbol Unit Description 1/2 General Features Type Spool valve Mounting 2 screws M6 Actuation: Hand lever Tube connection Thread - Detent Port size NPT (G) 1/2 - Spring Return Weight (mass) lbs. (kg) 2.64 (1.20) Installation In any position Note: Ambient ϑ °F (°C) 14 (-10) min temperature range ϑ 140 (+60) When using below freezing max point it is necessary to Medium ϑ °F (°C) 14 (-10) min consult factory. temperature range ϑ 158 (+70) max Medium Filtered compressed air 1) Lubrication With or without oil mist lubrication Pneumatic Characteristics Nominal pressure p psi (bar) 87 (6) n Operating pressure p psi (bar) 0 (0) min range p 145 (10) max Nominal flow Q Cv (I/min) 3.5 (3500) N Actuation Manual control Direct Stroke in (mm) .370 (9.4) Actuation force F lbf (N) 3.37 (15) detent b 8.99 (40) spring 1) We recommend the use of mineral oil type VG32 to ISO 3448 Dimensions (mm) 57 34 17 14 5 4 1 2 3 12 7 40 6,5 150 70 Version 1/2 Metric Version NPT Version Actuation Type Number Order Number Type Number Order Number 5/2 Hand Lever/Detent S9 511-1/2 PA 16367 S9 511-1/2U PD 45495 5/2 Hand Lever/Spring Return S9 511RF-1/2 PA 16366 S9 511RF-1/2U PD 45494 18 Parker Hannifin Corporation 19 Parker-Origa Glendale Heights, Illinois ORIGA www.parkeroriga.com 167 100 57 32 32 75 25 G1/2 32 91 83251 ORIC0C Body Ported Valves 10/2/03 9:18 AM Page 19 Catalog 0952 Valves Characteristics 5/3-Way Valve, 1/8 Inch Characteristics to VDI 3290 Pressures quoted as gauge pressure 5/3-Way Valve Characteristics Symbol Unit Description 1/8 General Features Type Spool valve Mounting 2 screws M5 Actuation: Hand lever Tube connection Thread - Detent Port size NPT (G) 1/8 - Spring Center Weight (mass) lbs. (kg) .429 (.195) Installation In any position Ambient ϑ °F (°C) 14 (-10) Note: min temperature range ϑ 140 (+60) When using below freezing max point it is necessary to Medium ϑ °F (°C) 14 (-10) min consult factory. temperature range ϑ 158 (+70) max Medium Filtered compressed air 1) Lubrication With or without oil mist lubrication Pneumatic Characteristics Nominal pressure p psi (bar) 87 (6) n Operating pressure p psi (bar) 0 (0) min range p 145 (10) max Nominal flow Q Cv (I/min) .5 (500) N Actuation Manual control Direct Stroke in (mm) .177 (4.5) Actuating force F lbf (N) G,E,B: 1.57 (7) b RFG, RFE, RFB: 2.25 (10) 1) We recommend the use of mineral oil type VG32 to ISO 3448 19 Parker Hannifin Corporation 20 Parker-Origa Glendale Heights, Illinois ORIGA www.parkeroriga.com 19°� 83251 ORIC0C Body Ported Valves 10/2/03 9:18 AM Page 20 Catalog 0952 Valves Dimensions & Ordering Information 5/3-Way Valve, 1/8 Inch Dimensions (mm) 94 29 20 7 14 5 4 1 2 3 12 5,5 22 5 40 Version 1/8 Metric Version NPT Version Actuation Symbol Type Number Order Number Type Number Order Number 4 2 14 5/3-way Hand Lever/Detent; Blocked S9 511G-1/8 PA 10321 S9 511G-1/8U PD 45471 5 13 4 2 14 5/3-way Hand Lever/Detent; Exhausted S9 511E-1/8 PA 10322 S9 511E-1/8U PD 45472 5 13 4 2 14 5/3-way Hand Lever/Detent; Dual S9 511B-1/8 PA 10323 S9 511B-1/8U PD 45473 5 13 4 2 14 12 5/3-way Hand Lever/Spring; Blocked S9 511RFG-1/8 PA 10324 S9 511RFG-1/8U PD 45474 5 13 4 2 14 12 5/3-way Hand Lever/Spring; Exhausted S9 511RFE-1/8 PA 10325 S9 511RFE-1/8U PD 45475 5 13 4 2 14 12 5/3-way Hand Lever/Spring; Dual S9 511RFB-1/8 PA 10326 S9 511RFB-1/8U PD 45476 5 13 20 Parker Hannifin Corporation 21 Parker-Origa Glendale Heights, Illinois ORIGA www.parkeroriga.com 95 55,5 31 18 18 41 G1/8 11,5 18 48 83251 ORIC0C Body Ported Valves 10/2/03 9:18 AM Page 21 Catalog 0952 Valves Characteristics 5/3-Way Valve, 1/4 Inch Characteristics to VDI 3290 Pressures quoted as gauge pressure 5/3-Way Valve Characteristics Symbol Unit Description 1/4 General Features Type Spool valve Mounting 2 screws M6 Actuation: Hand lever Tube connection Thread - Detent Port size NPT (G) 1/4 - Spring Center - Safety Detent Weight (mass) lbs. (kg) 1.14 (.52) Installation In any position Ambient ϑ °F (°C) 14 (-10) Note: min temperature range ϑ 140 (+60) When using below freezing max point it is necessary to Medium ϑ °F (°C) 14 (-10) min consult factory. temperature range ϑ 158 (+70) max Medium Filtered compressed air 1) Lubrication With or without oil mist lubrication Pneumatic Characteristics Nominal pressure p psi (bar) 87 (6) n Operating pressure p psi (bar) 0 (0) min range p 145 (10) max Nominal flow Q Cv (I/min) RFG, RFB: 1.3 (1300) N RFE: 1.0 (1000) Actuation Manual control Direct Stroke in (mm) .256 (6.5) Actuating force F lbf (N) G,E,B: 2.25 (10) b RFG, RFE, RFB: 3.37 (15) 1) We recommend the use of mineral oil type VG32 to ISO 3448 21 Parker Hannifin Corporation 22 Parker-Origa Glendale Heights, Illinois ORIGA www.parkeroriga.com 18°� 83251 ORIC0C Body Ported Valves 10/2/03 9:18 AM Page 22 Catalog 0952 Valves Dimensions & Ordering Information 5/3-Way Valve, 1/4 Inch Dimensions (mm) 121 44 122* 44 25 12 25 14 5 4 1 2 3 12 32 6,5 6 52 *Safety hand lever Version 1/4 Metric Version NPT Version Actuation Symbol Type Number Order Number Type Number Order Number 4 2 14 5/3-way Hand Lever/Detent; Blocked S9 511G-1/4 PA 12687 S9 511G-1/4U PD 45483 5 13 4 2 14 5/3-way Hand Lever/Detent; Exhausted S9 511E-1/4 PA 12688 S9 511E-1/4U PD 45484 5 13 4 2 14 5/3-way Hand Lever/Detent; Dual S9 511B-1/4 PA 12689 S9 511B-1/4U PD 45485 5 13 4 2 14 12 5/3-way Hand Lever/Spring; Blocked S9 511RFG-1/4 PA 12690 S9 511RFG-1/4U PD 45486 5 13 4 2 14 12 5/3-way Hand Lever/Spring; Exhausted S9 511RFE-1/4 PA 12691 S9 511RFE-1/4U PD 45487 5 13 4 2 14 12 5/3-way Hand Lever/Spring; Dual S9 511RFB-1/4 PA 12692 S9 511RFB-1/4U PD 45488 5 13 4 2 14 5/3-way Hand Lever/Detent; Blocked (safety) S9 511SG-1/4 PA 12693 S9 511SG-1/4U PD 45489 5 13 4 2 14 5/3-way Hand Lever/Detent; Exhausted (safety) S9 511SE-1/4 PA 12694 S9 511SE-1/4U PD 45490 5 13 4 2 14 5/3-way Hand Lever/Detent; Dual (safety) S9 511SB-1/4 PA 12695 S9 511SB-1/4U PD 45491 5 13 22 Parker Hannifin Corporation 23 Parker-Origa Glendale Heights, Illinois ORIGA www.parkeroriga.com 120 67 43,5 22 22 55 17 G1/4 22 66 20° 83251 ORIC0C Body Ported Valves 10/2/03 9:18 AM Page 23 Catalog 0952 Valves Characteristics & Dimensions 5/3-Way Valve, 1/2 Inch Characteristics to VDI 3290 Pressures quoted as gauge pressure 5/3-Way Valve Characteristics Symbol Unit Description 1/2 General Features Type Spool valve Mounting 2 screws M6 Actuation: Hand lever Tube connection Thread - Detent Port size NPT (G) 1/2 Weight (mass) lbs. (kg) 2.64 (1.20) Installation In any position Ambient ϑ °F (°C) 14 (-10) Note: min temperature range ϑ 140 (+60) When using below freezing max point it is necessary to Medium ϑ °F (°C) 14 (-10) min consult factory. temperature range ϑ 158 (+70) max Medium Filtered compressed air 1) Lubrication With or without oil mist lubrication Pneumatic Characteristics Nominal pressure p psi (bar) 87 (6) n Operating pressure p psi (bar) 0 (0) min range p 145 (10) max Nominal flow Q Cv (I/min) 3.5 (3500) N Actuation Manual control Direct Stroke in (mm) .370 (9.4) Actuating force F lbf (N) 3.37 (15) b 1) We recommend the use of mineral oil type VG32 to ISO 3448 Dimensions (mm) 57 34 17 14 5 4 1 2 3 12 7 40 6,5 151,5 70 Version 1/2 Metric Version NPT Version Actuation Symbol Type Number Order Number Type Number Order Number 4 2 14 5/3-way Hand Lever/Detent; Blocked S9 511G-1/2 PA 16369 S9 511G-1/2U PD 45496 5 13 23 Parker Hannifin Corporation 24 Parker-Origa Glendale Heights, Illinois ORIGA www.parkeroriga.com 167 100 57 32 32 75 25 G1/2 32 91 83251 ORIC0C Body Ported Valves 10/2/03 9:18 AM Page 24 Catalog 0952 Valves Characteristics & Ordering Information 5/2-Way Valve, 1/4 Inch Pressures quoted as gauge pressure 5/2-Way Valve Characteristics Unit Description 1/4 General Features Type Body ported valve Style Spool valve Interference Sensing Module Port size G 1/4 Weight (mass) lbs. (kg) 1.43 (0.65) The interference sensing module was Installation In any position designed to automatically reverse the Ambient temperature direction of a pneumatic cylinder, when minimum °F (°C) 14 (-10) it detects an obstruction. Loss of back maximum 140 (+60) pressure, caused by an obstruction, Medium temperature triggers the built-in pressure switch to minimum °F (°C) 14 (-10) shift the valve and retract the cylinder. maximum 158 (+70) Pneumatic Characteristics Applications: Medium Air • Doors • Machine Guards Nominal pressure psi (bar) 87 (6) • Conveyor Transfer Operating pressure • Pallet Handling minimum psi (bar) 22 (1.5) • Feed Systems maximum 116 (8) • Elevator Systems • Variable Height Pick & Place Nominal flow Cv (I/min) 1.3 (1300) Filtration 40 micron recommended 1) Lubrication With or without lubrication Electrical Characteristics Voltage AC V 110, 220 DC 12, 24 Duty cycle Continuous duty Electric protection IP65 to DIN 40050 Insulating Material VDE 0580 Connection Plug to DIN 43650 form B 1) We recommend the use of mineral oil type VG32 to ISO 3448 Version 1/4 Order Number Description Ports Voltage IS0250-0133 5/2-way IS-module G1/4 12vDC IS0250-0233 5/2-way IS-module G1/4 24vDC IS0250-5733 5/2-way IS-module G1/4 110vAC IS0250-6133 5/2-way IS-module G1/4 220vAC 24 Parker Hannifin Corporation 25 Parker-Origa Glendale Heights, Illinois ORIGA www.parkeroriga.com 83251 ORIC0C Body Ported Valves 10/2/03 9:18 AM Page 25 Catalog 0952 Valves Characteristics 5/2-Way & 5/3-Way Valve, ISO 5599, Size 1 Characteristics to VDI 3290 Pressures quoted as gauge pressure 5/2-Way Valve Characteristics Symbol Unit Description 5/3-Way Valve General Features Type Ceramic spool valve ISO 5599 Mounting On base plate, to ISO 5599 Size 1 Tube connection Base plate Port size G1/4 (base plate) Weight (mass) lbs. (kg) 1.01 (0.46) signal solenoid 1.30 (0.59) double solenoid Actuation: Solenoid Installation In any position - Single Solenoid Ambient ϑ °F (°C) 14 (-10) Note: - Double Solenoid min When using below freezing temperature range ϑ 140 (+60) - Spring Center max point it is necessary to Medium ϑ °F (°C) 14 (-10) min consult factory. temperature range ϑ 140 (+60) max Medium Filtered compressed air 1) Lubrication With or without oil mist lubrication Pneumatic Characteristics Nominal pressure p psi (bar) 87 (6) n Operating pressure p psi (bar) 29 (2) min range -1 (Version S) p psi (bar) 174 (12) max Nominal flow 5/2-way valve 5/3-way valve Delivery Includes: Q Cv (l/min) 1.7 (1680) 1.7 (1680) N valve Actuation mounting screws gasket Electrical Pilot operated solenoid coil(s) Pilot operated with external pilot air Actuation pressure p psi (bar) 29 (2) at min range p psi (bar) 145 (10) at max Voltage type AC DC Nominal Voltage Standard version U V 220 24 n Low watt. version U V 220 24 n Further voltages available on request Initial Power Consumption Standard version VA (W) 11 4.8 Low watt. version VA (W) 7.8 2.7 Continuous Power Consumption Standard version VA (W) 8.5 4.8 Low watt. version VA (W) 4.9 2.7 Duty cycle ED % Continuous Duty Electrical protection IP65 to DIN 40050 (with plug) Insulating material VDE 0580 Connection Plug to DIN 43650 form B 1) We recommend the use of mineral oil type VG32 to ISO 3448 25 Parker Hannifin Corporation 26 Parker-Origa Glendale Heights, Illinois ORIGA www.parkeroriga.com 83251 ORIC0C Body Ported Valves 10/2/03 9:18 AM Page 26 Catalog 0952 Valves Characteristics 5/2-Way & 5/3-Way Valve, ISO 5599, Size 1 Characteristics to VDI 3290 Pressures quoted as gauge pressure 5/2-Way Valve Characteristics Symbol Unit Description 5/3-Way Valve General Features Type Ceramic spool valve ISO 5599 Mounting On base plate, to ISO 5599 Size 1 Tube connection Base plate Port size G1/4 (base plate) Weight (mass) lbs. (kg) .70 (0.32) Actuation: Air Pilot Installation In any position Ambient ϑ °F (°C) 14 (-10) - Single Air Pilot Note: min temperature range ϑ 140 (+60) - Double Air Pilot When using below freezing max point it is necessary to - Spring Center Medium ϑ °F (°C) 14 (-10) min consult factory. temperature range ϑ 140 (+60) max Medium Filtered compressed air 1) Lubrication With or without oil mist lubrication Pneumatic Characteristics Nominal pressure p psi (bar) 87 (6) n Operating pressure p psi (bar) -13 (-0.9) min range p 174 (12) max Nominal flow 5/2-way valve 5/3-way valve Q Cv (l/min) 1.7 (1680) 1.7 (1680) N Actuation Pneumatic Direct Actuation pressure p psi (bar) 29 (2) st min range p psi (bar) 145 (10) st max Delivery Includes: valve 1) We recommend the use of mineral oil type VG32 to ISO 3448 mounting screws gasket C 26 Parker Hannifin Corporation 27 Parker-Origa Glendale Heights, Illinois ORIGA www.parkeroriga.com 83251 ORIC0C Body Ported Valves 10/2/03 9:18 AM Page 27 Catalog 0952 Valves Characteristics 5/2-Way & 5/3-Way Valve, ISO 5599, Size 2 Characteristics to VDI 3290 Pressures quoted as gauge pressure 5/2-Way Valve Characteristics Symbol Unit Description 5/3-Way Valve General Features Type Ceramic spool valve ISO 5599 Mounting On base plate, to ISO 5599 Size 2 Tube connection Base plate Port size G3/8 (base plate) Weight (mass) lbs. (kg) 1.54 (0.70) single solenoid 1.83 (0.83) double solenoid Actuation: Solenoid Installation In any position - Single Solenoid Ambient ϑ °F (°C) 14 (-10) Note: - Double Solenoid min temperature range ϑ 140 (+60) When using below freezing - Spring Center max point it is necessary to Medium ϑ °F (°C) 14 (-10) min consult factory. temperature range ϑ 140 (+60) max Medium Filtered compressed air 1) Lubrication With or without oil mist lubrication Pneumatic Characteristics Nominal pressure p psi (bar) 87 (6) n Operating pressure p psi (bar) 29 (2) min range -1 (Version S) p psi (bar) 174 (12) max Nominal flow 5/2-way valve 5/3-way valve Delivery Includes: Q Cv (l/min) 4.3 (4320) 4.3 (4320) valve N mounting screws Actuation gasket Electrical Pilot operated solenoid coil(s) Pilot operated with external pilot air Actuation pressure p bar 2 st min range p bar 12 st max Voltage type AC DC Nominal Voltage Standard version U V 220 24 n Low watt. version U V 220 24 n Further voltages available on request Initial Power Consumption Standard version VA (W) 11 4.8 Low watt. version VA (W) 7.8 2.7 Continuous Power Consumption Standard version VA (W) 8.5 4.8 Low watt. version VA (W) 4.9 2.7 Duty cycle ED % Continuous Duty Electrical protection IP65 to DIN 40050 (with plug) Insulating material VDE 0580 Connection Plug to DIN 43650 form B 1) We recommend the use of mineral oil type VG32 to ISO 3448 27 Parker Hannifin Corporation 28 Parker-Origa Glendale Heights, Illinois ORIGA www.parkeroriga.com 83251 ORIC0C Body Ported Valves 10/2/03 9:18 AM Page 28 Catalog 0952 Valves Characteristics 5/2-Way & 5/3-Way Valve, ISO 5599, Size 2 Characteristics to VDI 3290 Pressures quoted as gauge pressure 5/2-Way Valve Characteristics Symbol Unit Description 5/3-Way Valve General Features Type Ceramic spool valve ISO 5599 Mounting On base plate, to ISO 5599 Size 2 Tube connection Base plate Port size G3/8 (base plate) Weight (mass) lbs. (kg) 1.23 (0.56) Actuation: Air Pilot Installation In any position Ambient ϑ °F (°C) 14 (-10) Note: - Single Air Pilot min - Double Air Pilot temperature range ϑ 140 (+60) When using below freezing max - Spring Center point it is necessary to Medium ϑ °F (°C) 14 (-10) min consult factory. temperature range ϑ 140 (+60) max Medium Filtered compressed air 1) Lubrication With or without oil mist lubrication Pneumatic Characteristics Nominal pressure p psi (bar) 87 (6) n Operating pressure p psi (bar) -13 (-0.9) min range p 174 (12) max Nominal flow 5/2-way valve 5/3-way valve Q Cv (l/min) 4.3 (4320) 4.3 (4320) N Actuation Pneumatic Direct Actuation pressure p psi (bar) 29 (2) st min range p psi (bar) 174 (12) st max Delivery Includes: 1) We recommend the use of mineral oil type VG32 to ISO 3448 valve mounting screws gasket 28 Parker Hannifin Corporation 29 Parker-Origa Glendale Heights, Illinois ORIGA www.parkeroriga.com 83251 ORIC0C Body Ported Valves 10/2/03 9:18 AM Page 29 Catalog 0952 Valves Characteristics 5/2-Way & 5/3-Way Valve, ISO 5599, Size 3 Characteristics to VDI 3290 Pressures quoted as gauge pressure 5/2-Way Valve Characteristics Symbol Unit Description 5/3-Way Valve General Features Type Ceramic spool valve ISO 5599 Mounting On base plate, to ISO 5599 Size 3 Tube connection Base plate Port size G1/2 (base plate) Weight (mass) lbs. (kg) 2.71 (1.23) single solenoid 3.01 (1.37) double solenoid Actuation: Solenoid Installation In any position - Single Solenoid Note: - Double Solenoid Ambient ϑ °F (°C) 14 (-10) min temperature range ϑ 140 (+60) When using below freezing - Spring Center max point it is necessary to Medium ϑ °F (°C) 14 (-10) min consult factory. temperature range ϑ 140 (+60) max Medium Filtered compressed air 1) Lubrication With or without oil mist lubrication Pneumatic Characteristics Nominal pressure p psi (bar) 87 (6) n Operating pressure p psi (bar) 29 (2) min range -1 (Version S) p psi (bar) 174 (12) max Nominal flow 5/2-way valve 5/3-way valve Q Cv (l/min) 6.5 (6540) 6.5 (6540) N Delivery Includes: Actuation valve Electrical Pilot operated mounting screws Pilot operated with external pilot air gasket solenoid coil(s) Actuation pressure p psi (bar) 29 (2) st min range p psi (bar) 145 (10) st max Voltage type AC DC 68 Nominal Voltage Standard version U V 220 24 n Low watt. version U V 220 24 n Further voltages available on request Initial Power Consumption Standard version VA (W) 11 4.8 Low watt. version VA (W) 7.8 2.7 Continuous Power Consumption Standard version VA (W) 8.5 4.8 Low watt. version VA (W) 4.9 2.7 Duty cycle ED % Continuous Duty Electrical protection IP65 to DIN 40050 (with plug) Insulating material VDE 0580 Connection Plug to DIN 43650 form B 1) We recommend the use of mineral oil type VG32 to ISO 3448 29 Parker Hannifin Corporation 30 Parker-Origa Glendale Heights, Illinois ORIGA www.parkeroriga.com 83251 ORIC0C Body Ported Valves 10/2/03 9:18 AM Page 30 Catalog 0952 Valves Characteristics 5/2-Way & 5/3-Way Valve, ISO 5599, Size 3 Characteristics to VDI 3290 Pressures quoted as gauge pressure 5/2-Way Valve Characteristics Symbol Unit Description 5/3-Way Valve General Features Type Ceramic spool valve ISO 5599 Mounting On base plate, to ISO 5599 Size 3 Tube connection Base plate Port size G1/2 (base plate) Weight (mass) lbs. (kg) 2.42 (1.1) Actuation: Air Pilot Installation In any position - Single Air Pilot Ambient ϑ °F (°C) 14 (-10) Note: min temperature range ϑ 140 (+60) - Double Air Pilot When using below freezing max point it is necessary to - Spring Center Medium ϑ °F (°C) 14 (-10) min consult factory. temperature range ϑ 140 (+60) max Medium Filtered compressed air 1) Lubrication With or without oil mist lubrication Pneumatic Characteristics Nominal pressure p psi (bar) 87 (6) n Operating pressure p psi (bar) -13 (-0.9) min range p 174 (12) max Nominal flow 5/2-way valve 5/3-way valve Q 1/min 6.5 (6540) 6.5 (6540) N Actuation Pneumatic Direct Actuation pressure p psi (bar) 29 (2) st min range p psi (bar) 174 (12) st max Delivery Includes: 1) We recommend the use of mineral oil type VG32 to ISO 3448 valve mounting screws gasket 30 Parker Hannifin Corporation 31 Parker-Origa Glendale Heights, Illinois ORIGA www.parkeroriga.com 83251 ORIC0C Body Ported Valves 10/2/03 9:18 AM Page 31 Catalog 0952 Valves Ordering Information 5/2-Way Valves ORDER INSTRUCTIONS: 5/2-Way Valves Actuation Symbol Type Number Order Number Size 5/2 Single Air Pilot S20561RF-01 PA 12891 VDMA 01 4 2 12 14 Spring Return S20561RF-1 PA 12869 Size 1 513 S20561RF-2 PA 16425 Size 2 S20561RF-3 PA 16426 Size 3 5/2 Single Air Pilot S20561R-01 PA 12892 VDMA 01 4 2 14 12 Air Spring Return S20561R-1 PA 12870 Size 1 S20561R-2 PA 16428 Size 2 513 S20561R-3 PA 16429 Size 3 5/2 Double Air Pilot S20561-01 PA 12893 VDMA 01 4 2 14 12 S20561-1 PA 12868 Size 1 S20561-2 PA 16422 Size 2 513 S20561-3 PA 16423 Size 3 5/2 Single Solenoid S20581RF-01-.. PA 12886-..33 VDMA 01 4 2 14 12 Spring Return S20581RF-1-.. PA 12875-..33 Size 1 S20581RF-2-.. PA 16441-..33 Size 2 513 S20581RF-3-.. PA 16442-..33 Size 3 5/2 Single Solenoid S20581S-RF-01-.. PA 12896-..33 VDMA 01 4 2 14 12 Spring Return S20581S-RF-1-.. PA 12882-..33 Size 1 with external pilot air S20581S-RF-2-.. PA 16456-..33 Size 2 p 513 st S20581S-RF-3-.. PA 16462-..33 Size 3 5/2 Single Solenoid S20581R-01-.. PA 12887-..33 VDMA 01 4 2 14 12 Air Spring Return S20581R-1-.. PA 12876-..33 Size 1 S20581R-2-.. PA 16444-..33 Size 2 513 S20581R-3-.. PA 16445-..33 Size 3 5/2 Double Solenoid 4 2 S20581-01-.. PA 12888-..33 VDMA 01 14 12 S20581-1-.. PA 12874-..33 Size 1 513 S20581-2-.. PA 16438-..33 Size 2 S20581-3-.. PA 16439-..33 Size 3 5/2 Double Solenoid S20581S-01-.. PA 12898-..33 VDMA 01 4 2 14 12 with external pilot air S20581S-1-.. PA 12880-..33 Size 1 pst pst S20581S-2-.. PA 16454-..33 Size 2 513 S20581S-3-.. PA 16460-..33 Size 3 Voltage Range Nominal Secondary Coil Number Order Code 12 vDC -- KZ 3518 01 24 vDC 60 50/60Hz KZ 3519 02 110 50/60Hz 48 vDC KZ 3521 57 220 50/60Hz 110 vDC KZ 3522 61 • Other voltages available. Contact factory. Parker Hannifin Corporation 31 32 Parker-Origa Glendale Heights, Illinois ORIGA www.parkeroriga.com 83251 ORIC0C Body Ported Valves 10/2/03 9:18 AM Page 32 Catalog 0952 Valves Ordering Information 5/3-Way Valves ORDER INSTRUCTIONS: 5/3-Way Valves Actuation Symbol Type Number Order Number Size 5/3 Double Air Pilot S20561RFG-01 PA 12894 VDMA 01 4 2 Closed Center 14 12 S20561RFG-1 PA 12871 Size 1 S20561RFG-2 PA 16431 Size 2 513 S20561RFG-3 PA 16432 Size 3 4 2 Dual Center S20561RFB-1 PA 12873 Size 1 14 12 S20561RFB-2 PA 16437 Size 2 513 Open Center S20561RFE-01 PA 12895 VDMA 01 4 2 14 12 S20561RFE-1 PA 12872 Size 1 S20561RFE-2 PA 16434 Size 2 513 S20561RFE-3 PA 16435 Size 3 5/3 Double Solenoid 4 2 S20581RFG-01 PA 12889-..33 VDMA 01 14 12 Closed Center S20581RFG-1-.. PA 12877-..33 Size 1 513 S20581RFG-2-.. PA 16447-..33 Size 2 S20581RFG-3-.. PA 16448-..33 Size 3 4 2 Dual Center S20581RFB-1-.. PA 12879-..33 Size 1 14 12 S20581RFB-2-.. PA 16453-..33 Size 2 513 Open Center S20581RFE-01 PA 12890-..33 VDMA 01 4 2 14 12 S20581RFE-1-.. PA 12878-..33 Size 1 S20581RFE-2-.. PA 16450-..33 Size 2 513 S20581RFE-3-.. PA 16451-..33 Size 3 5/3 Double Solenoid S20581S-RFG-01-.. PA 12900-..33 VDMA 01 4 2 12 14 with external air pilot S20581S-RFG-1-.. PA 12883-..33 Size 1 pst pst 513 Closed Center S20581S-RFG-2-.. PA 16457-..33 Size 2 S20581S-RFG-3-.. PA 16463-..33 Size 3 4 2 Dual Center 14 12 S20581S-RFB-1-.. PA 12885-..33 Size 1 S20581S-RFB-2-.. PA 16459-..33 Size 2 pst 513 pst Open Center S20581S-RFE-01-.. PA 12899-..33 VDMA 01 4 2 12 14 S20581S-RFE-1-.. PA 12884-..33 Size 1 pst pst 513 S20581S-RFE-2-.. PA 16458-..33 Size 2 S20581S-RFE-3-.. PA 16464-..33 Size 3 Voltage Range Nominal Secondary Coil Number Order Code 12 vDC -- KZ 3518 01 24 vDC 60 50/60Hz KZ 3519 02 110 50/60Hz 48 vDC KZ 3521 57 220 50/60Hz 110 vDC KZ 3522 61 • Other voltages available. Contact factory. 32 Parker Hannifin Corporation 33 Parker-Origa Glendale Heights, Illinois ORIGA www.parkeroriga.com 83251 ORIC0C Body Ported Valves 10/2/03 9:18 AM Page 33 Catalog 0952 Valves Characteristics 5/2-Way Valve, 1/8 Inch, NAMUR Characteristics to VDI 3290 Pressures quoted as gauge pressure 5/2-Way Valve Characteristics Symbol Unit Description 1/8 General Features with NAMUR connection Type Spool valve Mounting 2 screws M5 Tube connection Thread Actuation: Solenoid Port size NPT (G) 1/8 - Single Solenoid - Double Solenoid Weight (mass) lbs. (kg) .616 (0.280) Single solenoid .913 (0.415) Double solenoid Installation In any position Note: Ambient ϑ °F (°C) 14 (-10) min When using below freezing temperature range ϑ 140 (+60) max point it is necessary to Medium ϑ °F (°C) 14 (-10) min consult factory. temperature range ϑ 158 (+70) max Medium Filtered compressed air 1) Lubrication With or without oil mist lubrication Pneumatic Characteristics Nominal pressure p psi (bar) 87 (6) n Operating pressure Single solenoid range p psi (bar) 29 (2) min p 145 (10) max Double solenoid p psi (bar) 22 (1.5) min p 145 (10) max Nominal flow Q Cv (I/min) .5 (500) N Actuation Delivery Includes: Electrical Pilot operated valve Voltage AC DC mounting screws coding pin Nominal voltage* o-rings Standard version U V 220 24 n Initial power consumption Standard version VA (W) 8.5 2.5 Continuous consumption Standard version VA (W) 6.0 2.5 Duty cycle ED % Continuous Duty Electrical protection IP65 to DIN 40050 (with plug) Insulating material VDE 0580 Connection Plug to DIN 43650 form B 1) We recommend the use of mineral oil type VG32 to ISO 3448 33 Parker Hannifin Corporation 34 Parker-Origa Glendale Heights, Illinois ORIGA www.parkeroriga.com 83251 ORIC0C Body Ported Valves 10/2/03 9:18 AM Page 34 Catalog 0952 Valves Dimensions & Ordering Information 5/2-Way Valve, 1/8 Inch, NAMUR Dimensions (mm) 14 19,5 5 4 1 2 3 4 32 12 Mounting Dimensions to NAMUR standards 15,5 22 40 63 Version 1/8 Metric Version NPT Version Actuation Symbol Type Number Order Number Type Number Order Number 4 2 14 12 5/2 Single Solenoid/Spring Return S9 581RF-1/8-SO PD 34143-..33 S9 581RF-1/8U-SO PD 45502-..33 5 13 4 2 14 12 5/2 Double Solenoid S9 581-1/8-SO PD 34984-..33 S9 581-1/8U-SO PD 45503-..33 513 Voltage Range • Other voltages available. Contact factory. Nominal Secondary Coil Number Order Code • Explosion proof coils available. Contact factory. • UL/CSA rated coils available. Contact factory. 12 vDC -- KZ 3674 01 24 vDC 60 50/60Hz KZ 3673 02 110 50/60Hz 48 vDC KZ 3669 57 220 50/60Hz 110 vDC KZ 3672 61 24 50/60Hz -- KZ 3675 51 Accessory: Order # Description NAMURPLATE-1/8 Converts the 5/2-way valve to a 3/2-way valve Parker Hannifin Corporation 34 35 Parker-Origa Glendale Heights, Illinois ORIGA www.parkeroriga.com 5,2 ca.208 24 22 12 5,5 x 3 deep 3 M5 G1/8 10,5 16 28 18 18 33,5 15,5 87,5 56 128 ca.140 83251 ORIC0C Body Ported Valves 10/2/03 9:18 AM Page 35 Catalog 0952 Valves Characteristics 5/2-Way Valve, 1/4 Inch, NAMUR Characteristics to VDI 3290 Pressures quoted as gauge pressure 5/2-Way Valve Characteristics Symbol Unit Description 1/4 General Features with NAMUR connection Type Spool valve Mounting 2 screws M5 Tube connection Thread Actuation: Solenoid Port size NPT (G) 1/4 - Single Solenoid - Double Solenoid Weight (mass) lbs. (kg) 1.32 (0.6) Single solenoid 1.54 (0.7) Double solenoid Installation In any position Note: Ambient ϑ °F (°C) 14 (-10) min When using below freezing temperature range ϑ 140 (+60) max point it is necessary to Medium ϑ °F (°C) 14 (-10) min consult factory. temperature range ϑ 158 (+70) max Medium Filtered compressed air 1) Lubrication With or without oil mist lubrication Pneumatic Characteristics Nominal pressure p psi (bar) 87 (6) n Operating pressure Single solenoid range p psi (bar) 29 (2) min p 145 (10) max Double solenoid p psi (bar) 22 (1.5) min Delivery Includes: p 145 (10) max valve mounting screws Nominal flow Q Cv (I/min) 1.3 (1300) N coding pin Actuation o-rings Electrical Pilot operated Voltage AC DC Nominal voltage* Standard version U V 220 24 n Initial power consumption Standard version VA (W) 8.5 2.5 Continuous consumption Standard version VA (W) 6.0 2.5 Duty cycle ED % Continuous Duty Electrical protection IP65 to DIN 40050 (with plug) Insulating material VDE 0580 Connection Plug to DIN 43650 form B 1) We recommend the use of mineral oil type VG32 to ISO 3448 Parker Hannifin Corporation 35 36 Parker-Origa Glendale Heights, Illinois ORIGA www.parkeroriga.com 83251 ORIC0C Body Ported Valves 10/2/03 9:19 AM Page 36 Catalog 0952 Valves Dimensions & Ordering Information 5/2-Way Valve, 1/4 Inch, NAMUR Dimensions (mm) 32 22 14 9 3 5,2 5 4 1 2 3 19,5 32 Mounting Dimensions 12 to NAMUR standards 15,5 52 63 Version 1/4 Metric Version NPT Version Actuation Symbol Type Number Order Number Type Number Order Number 4 2 14 12 5/2 Single Solenoid/Spring Return S9 581RF-1/4-SO PD 34985-..33 S9 581RF-1/4U-SO PD 45504-..33 5 13 4 2 14 12 5/2 Double Solenoid S9 581-1/4-SO PD 34986-..33 S9 581-1/4U-SO PD 45505-..33 513 Voltage Range • Other voltages available. Contact factory. • Explosion proof coils available. Contact factory. Nominal Secondary Coil Number Order Code • UL/CSA rated coils available. Contact factory. 12 vDC -- KZ 3674 01 24 vDC 60 50/60Hz KZ 3673 02 110 50/60Hz 48 vDC KZ 3669 57 220 50/60Hz 110 vDC KZ 3672 61 24 50/60Hz -- KZ 3675 51 Accessory: Order # Description NAMURPLATE-1/4 Converts the 5/2-way valve to a 3/2-way valve 3 36 6 Parker Hannifin Corporation 37 Parker-Origa Glendale Heights, Illinois ORIGA www.parkeroriga.com M5 10 24 30,5 12 5,5 x 3 deep ca.231 20,7 32,7 G1/4 22 22 41 106 20 62 148 ca.159 12 83251 ORIC0C Body Ported Valves 10/2/03 9:19 AM Page 37 Catalog 0952 Valves Characteristics & Dimensions 5/2-Way Valve, 1/8 Inch, Safety Operation Characteristics to VDI 3290 Pressures quoted as gauge pressure 5/2-Way Valve Characteristics Symbol Unit Description 1/8 General Features for two-hand safety operation Type Spool valve Mounting 2 screws M5 (M3) Tube connection Thread Actuation: Pneumatic Port size NPT (G) 1/8 Weight (mass) lbs. (kg) .594 (.27) 4 2 Installation In any position 12.1 ≥1 & t Ambient ϑ °F (°C) 14 (-10) Note: min temperature range ϑ 140 (+60) When using below freezing max point it is necessary to Medium ϑ °F (°C) 14 (-10) min 12.2 consult factory. temperature range ϑ 158 (+70) max Medium Filtered compressed air 5 13 1) Lubrication With or without oil mist lubrication Pneumatic Characteristics • The valve switches from outlet 4 to Nominal pressure p psi (bar) 87 (6) n outlet 2 only if both signal inputs are Operating pressure p psi (bar) 0 (0) actuated simultaneously or within 0.5 min range p 145 (10) seconds. max • The valve will not switch again until Nominal flow Q Cv (I/min) .5 (500) N both signal inputs are stopped. Actuation • For the safety of operating personnel in manufacturing processes such as Pneumatic Direct pressing, bending, stamping, Actuating pressure p psi (bar) 29 (2) st min deburring etc. range p 145 (10) st max • Not suitable for control systems of 1) We recommend the use of mineral oil type VG32 to ISO 3448 eccentric or similar presses. Dimensions (mm) 45 14 5 4 1 2 3 12 12/1 12/2 G1/8 5 5,5 22 40 Version 1/8 Metric Version NPT Version Description Type Number Order Number Type Number Order Number Two-hand safety valve S9 563/65RF-1/8-SO PD 37673 S9 563/65RF-1/8U-SO PD 45506 3 37 7 Parker Hannifin Corporation 38 Parker-Origa Glendale Heights, Illinois ORIGA www.parkeroriga.com 72 55,5 8,25 18 18 18 G1/8 18 36,7 18 27 141 83251 ORIC0C Body Ported Valves 10/2/03 9:19 AM Page 38 Catalog 0952 Valves Characteristics & Dimensions 5/2-Way Valve, 1/4 Inch, Safety Operation Characteristics to VDI 3290 Pressures quoted as gauge pressure 5/2-Way Valve Characteristics Symbol Unit Description 1/4 General Features for two-hand safety operation Type Spool valve Mounting 2 screws M6 Tube connection Thread Actuation: Pneumatic Port size NPT (G) 1/4 4 2 Weight (mass) lbs. (kg) 1.41 (.64) 12.1 Installation In any position ≥1 & t Ambient ϑ °F (°C) 14 (-10) Note: min temperature range ϑ 140 (+60) When using below freezing max point it is necessary to 12.2 Medium ϑ °F (°C) 14 (-10) min consult factory. temperature range ϑ 158 (+70) max 5 13 Medium Filtered compressed air 1) Lubrication With or without oil mist lubrication • The valve switches from outlet 4 to Pneumatic Characteristics outlet 2 only if both signal inputs are Nominal pressure p psi (bar) 87 (6) n actuated simultaneously or within 0.5 Operating pressure p psi (bar) 0 (0) seconds. min range p 145 (10) • The valve will not switch again until max both signal inputs are stopped. Nominal flow Q Cv (I/min) 1.3 (1300) N • For the safety of operating personnel Actuation in manufacturing processes such as pressing, bending, stamping, Pneumatic Directly deburring etc. Control pressure p psi (bar) 44 (3) st min • Not suitable for control systems of range p 145 (10) st max eccentric or similar presses. 1) We recommend the use of mineral oil type VG32 to ISO 3448 Dimensions (mm) 62 25 14 5 4 1 2 4,5 3 12 12.1 12.2 6,5 32 6 52 Version 1/4 Metric Version NPT Version Description Type Number Order Number Type Number Order Number Two-hand safety valve S9 563/65RF-1/4-SO PD 37173 S9 563/65RF-1/4U-SO PD 45507 38 Parker Hannifin Corporation 39 Parker-Origa Glendale Heights, Illinois ORIGA www.parkeroriga.com 166 25 141 67 64,5 22 36 22 76 G1/4 55 G1/8 ø4,2 ø7,5 47 22 87 11 5,5 83251 ORIC0C Body Ported Valves 10/2/03 9:19 AM Page 39 Catalog 0952 Valves Characteristics & Dimensions 5/2-Way Valve, 1/4 Inch, Pneumatic Oscillating Characteristics to VDI 3290 Pressures quoted as gauge pressure 5/2-Way Valve Characteristics Symbol Unit Description 1/4 General Features oscillating valve System Spool valve Mounting 2 screws M6 (M4) Tube connection Thread Actuation: Pneumatic Port size NPT (G) 1/4 4 2 Weight (mass) lbs. (kg) 1.43 (0.65) Installation In any position & & Ambient ϑ °F (°C) 14 (-10) Note: min temperature range ϑ 140 (+60) When using below freezing max point it is necessary to Medium ϑ °F (°C) 14 (-10) min consult factory. temperature range ϑ 158 (+70) max 5 13 Medium Filtered compressed air 1) Lubrication With or without oil mist lubrication The oscillating valve automatically gen- Pneumatic Characteristics erates reciprocating movements, for Nominal pressure p psi (bar) 87 (6) n applications such as shaking, feeding, Operating pressure p psi (bar) 36 (3) min hammering, plunging, scraping, wiping, range p 118 (8) winding, tensioning, raking, diverting, max spraying, cleaning, and dipping. Nominal flow Q Cv (I/min) 1.3 (1300) N The oscillating valve is supplied with Actuation two built-in flow control valves. This Pneumatic Direct makes it easy to adjust the stroke fre- Actuating pressure p psi (bar) 36 (3) quency of the actuator. st min range p 118 (8) st max Pneumatic Version: 1) If compressed air is introduced into inlet We recommend the use of mineral oil type VG32 to ISO 3448 port 1, the outlet ports 4 and 2 are alter- nately supplied with air. Dimensions (mm) 62 32 24 25 14 5 4 1 2 4,5 3 12 6,5 32 6 52 Version 1/4 Metric Version NPT Version Description Type Number Order Number Type Number Order Number Oscillating valve S9 568/68-1/4-SO PD 34796 S9 568/68-1/4U-SO PD 45508 39 Parker Hannifin Corporation 40 Parker-Origa Glendale Heights, Illinois ORIGA www.parkeroriga.com 196 25 111 30 67 34,5 22 46 22 G1/4 25 ø4,2 ø7,5 22 57 11 5,5 83251 ORIC0C Body Ported Valves 10/2/03 9:19 AM Page 40 Catalog 0952 Valves Characteristics & Ordering Information 5/2-Way Valve, 1/4 Inch, Electric Oscillating Characteristics to VDI 3290 Pressures quoted as gauge pressure 5/2-Way Valve Characteristics Unit Description 1/4 General Features Oscillating Valve Type Body ported valve Style Spool valve Mounting 2 screws M6 (M4) Actuation: Electric Tube connection Thread Port size NPT (G) 1/4 Electric Version: Weight (mass) lbs. (kg) 1.70 (.77) Compressed air is introduced into inlet Installation In any position port 1. The outlet ports 4 and 2 are alternately supplied with air, for as long Ambient temperature as an electrical signal is present at the minimum °F (°C) 14 (-10) solenoid coil. maximum 140 (+60) Medium temperature minimum °F (°C) 14 (-10) maximum 158 (+70) Pneumatic Characteristics Medium Air Nominal pressure psi (bar) 131 (6) Operating pressure minimum psi (bar) 36 (3) maximum 118 (8) Nominal flow Cv (I/min) 1.3 (1300) Filtration 40 micron recommended 1) Lubrication With or without lubrication Electrical Characteristics Voltage AC V 110, 220 DC 12, 24 Duty cycle Continuous Duty Electric protection IP65 to DIN 40050 Insulating Material VDE 0580 Connection Plug to DIN 43650 form B Actuation Electric (Internal) pilot operated manual override yes 1) We recommend the use of mineral oil type VG32 to ISO 3448 Version 1/4 Order Number Description Ports Voltage PD 47166-0133 5/2-way oscillating valve 1/4" NPT 12vDC PD 47166-0233 5/2-way oscillating valve 1/4" NPT 24vDC PD 47166-5733 5/2-way oscillating valve 1/4" NPT 110vAC 40 Parker Hannifin Corporation 41 Parker-Origa Glendale Heights, Illinois ORIGA www.parkeroriga.com 83251 ORIC0C Body Ported Valves 10/2/03 9:19 AM Page 41 Catalog 0952 Valves Characteristics 3/2-Way Valve, 1/4 Inch, Foot Pedal Characteristics to VDI 3290 Pressures quoted as gauge pressure 3/2-Way Valve Characteristics Symbol Unit Description 1/4 General Features System Poppet valve Mounting After removing the rubber footing Actuation: Foot Pedal 4 screws M8 - Detent Tube connection Thread - Spring Return Port size G1/4 Weight (mass) lbs. (kg) 3.08 (1.5) Installation In any position Ambient ϑ °F (°C) 14 (-10) Note: min temperature range ϑ 131 (+55) When using below freezing max point it is necessary to Medium ϑ °F (°C) 14 (-10) min consult factory. temperature range ϑ 140 (+60) max Medium Filtered compressed air Lubrication Oil mist lubrication compatible with Buna N Pneumatic Characteristics Nominal pressure p psi (bar) 87 (6) n Operating pressure p psi (bar) 0 (0) min range p 145 (10) max Nominal flow Q Cv (I/min) 1.4 (1400) N Actuation Manual control Direct Stroke mm 2 Actuating force Fb lbf (N) 6.74 (30) Delivery Includes: valve toe guard Parker Hannifin Corporation 41 42 Parker-Origa Glendale Heights, Illinois ORIGA www.parkeroriga.com 83251 ORIC0C Body Ported Valves 10/2/03 9:19 AM Page 42 Catalog 0952 Valves Dimensions & Ordering Information 3/2-Way Valve, 1/4 Inch, Foot Pedal Dimensions (mm) 215 152 13 * S R B A P 24 ø8,2 165 31 190 61 90 1 1 5 Connection: Version "normally closed": P, B, S Version "normally open": P, A, R Only for version "both switch positions Mounting instruction: * indexed" - return is only effected after Only use screw connections with actuating the locking pedal. max. wrench size across flats of 15. METRIC ONLY Version G1/4 Actuation Return Symbol Type Number Order Number B a b a b F331RF-08NG* KZ 4410 P S A Pedal Spring return a b a b F331RF-08NO* KZ 4411 P R B a,b a b F331-08NG* KZ 4408 P S Pedal Detent A a,b a b F331-08NO* KZ 4409 P R *NG = normally closed, NO = normally open Parker Hannifin Corporation 42 43 Parker-Origa Glendale Heights, Illinois ORIGA www.parkeroriga.com 91 8 20 Actuation stroke 3 133 G1/4 10 20 38 83251 ORIC0C Body Ported Valves 10/2/03 9:19 AM Page 43 Catalog 0952 Valves Characteristics 5/2-Way Valve, 1/4 Inch, Foot Pedal Characteristics to VDI 3290 Pressures quoted as gauge pressure 5/2-Way Valve Characteristics Symbol Unit Description 1/4 General Features System Poppet valve Mounting After removing the rubber footing Actuation: Foot Pedal 4 screws M8 - Detent Tube connection Thread - Spring Return Port size G1/4 Weight (mass) lbs. (kg) 3.08 (1.5) Installation In any position Ambient ϑ °F (°C) 14 (-10) Note: min temperature range ϑ 131 (+55) When using below freezing max point it is necessary to Medium ϑ °F (°C) 14 (-10) min consult factory. temperature range ϑ 140 (+60) max Medium Filtered compressed air Lubrication Oil mist lubrication compatible with Buna N Pneumatic Characteristics Nominal pressure p psi (bar) 87 (6) n Operating pressure p psi (bar) 0 (0) min range p 10 145 (10) max Nominal flow Q Cv (I/min) 1.4 (1400) N Actuation Manual control Direct Stroke mm 2 Actuating force Fb lbf (N) 6.74 (30) Delivery Includes: valve toe guard Parker Hannifin Corporation 43 44 Parker-Origa Glendale Heights, Illinois ORIGA www.parkeroriga.com 83251 ORIC0C Body Ported Valves 10/2/03 9:19 AM Page 44 Catalog 0952 Valves Dimensions & Ordering Information 5/2-Way Valve, 1/4 Inch, Foot Pedal Dimensions (mm) 215 152 13 * S R A B P ø8,2 24 165 31 61 190 90 1 1 5 * Only for version "both switch positions Mounting instruction: Only use screw connections with indexed" - return is only effected after actuating the locking pedal. max. wrench size across flats of 15. METRIC ONLY Version G1/4 Actuation Return Symbol Type Number Order Number A B a b Pedal Spring return F531RF-08 KZ 4413 RPS A B a,b Pedal Detent F531-08 KZ 4412 RPS Parker Hannifin Corporation 44 45 Parker-Origa Glendale Heights, Illinois ORIGA www.parkeroriga.com 91 8 20 Actuation stroke 3 133 G1/4 10 20 38 83251 ORIC0C Body Ported Valves 10/2/03 9:19 AM Page 45 Catalog 0952 Valves Dimensions & Ordering Information RPS-Supply Manifolds, 1/8 Inch, Metric Dimensions (mm) RPS-Supply For dimensions A and B see table Manifolds 65 25 for directional valves of the 49,5 23 23 12 1 1 S9-1/8 Series 9 5 Metric Only Body Ported Valves 1 3 29,5 B A Drawing shows: RPSL-S9-1/8-3 Dimension Table (mm) Material Type # # of A B Description Material valves RPS-supply mani. AI, anodized RPSL-S9-1/8-2 2 74 63 Screws Galvanized steel RPSL-S9-1/8-3 3 96 86 O-ring Oil-resist. rubber RPSL-S9-1/8-4 4 118 109 Versions: RPSL-S9-1/8-5 5 140 132 5/2-way valves RPSL-S9-1/8-6 6 162 155 Accessories 5/3-way valves RPSL-S9-1/8-7 7 184 178 Description Order No. RPSL-S9-1/8-8 8 206 201 Complete RPSL-S9-1/8-9 9 228 224 cover strip PD 32956 Delivery Includes: RPSL-S9-1/8-10 10 250 247 RPS-supply manifold Flow divider PD 42483 mounting screws o-rings Order Instructions Quantity Weight Type # Order # Manifold Screws O-rings (kg) RPSL-S9-1/8-2 PD 44813-0002 1 4 6 0.47 RPSL-S9-1/8-3 PD 44813-0003 1 6 9 0.57 RPSL-S9-1/8-4 PD 44813-0004 1 8 12 0.67 RPSL-S9-1/8-5 PD 44813-0005 1 10 15 0.77 RPSL-S9-1/8-6 PD 44813-0006 1 12 18 0.87 RPSL-S9-1/8-7 PD 44813-0007 1 14 21 0.97 RPSL-S9-1/8-8 PD 44813-0008 1 16 24 1.07 RPSL-S9-1/8-9 PD 44813-0009 1 18 27 1.17 RPSL-S9-1/8-10 PD 44813-0010 1 20 30 1.27 Parker Hannifin Corporation 46 45 Parker-Origa Glendale Heights, Illinois ORIGA www.parkeroriga.com 5,5 20,5 19x0,2 deep G1/4 43 99 83251 ORIC0C Body Ported Valves 10/2/03 9:19 AM Page 46 Catalog 0952 Valves Dimensions & Ordering Information RPS-Supply Manifolds, 1/4 Inch, Metric Dimensions (mm) RPS-Supply For dimensions A and B see table Manifolds 83 31 54,5 54,5 33 33 for directional valves of the 18,5 12,5 S9-1/4 Series 12 5 Metric Only Body Ported Valves 1 3 29,5 B A Drawing shows: RPSL-S9-1/4-3 Dimension Table (mm) Material Type # # of A B Description Material valves RPS-supply mani. Anodized alum. RPSL-S9-1/4-2 2 96 83 Screws Galvanized steel RPSL-S9-1/4-3 3 129 116 O-ring Oil-resist. rubber RPSL-S9-1/4-4 4 162 149 Versions: RPSL-S9-1/4-5 5 195 182 5/2-way valves RPSL-S9-1/4-6 6 228 215 5/3-way valves Accessories RPSL-S9-1/4-7 7 261 248 RPSL-S9-1/4-8 8 294 281 Description Order No. Cover strip kit PD 32957 RPSL-S9-1/4-9 9 327 314 Delivery Includes: RPS-supply manifold RPSL-S9-1/4-10 10 360 347 Flow divider PD 42516 mounting screws o-rings Order Instructions Quantity Weight Type # Order # Manifold Screws O-rings (kg) RPSL-S9-1/4-2 PD 44814-0002 1 4 6 0.845 RPSL-S9-1/4-3 PD 44814-0003 1 6 9 1.045 RPSL-S9-1/4-4 PD 44814-0004 1 8 12 1.245 RPSL-S9-1/4-5 PD 44814-0005 1 10 15 1.445 RPSL-S9-1/4-6 PD 44814-0006 1 12 18 1.645 RPSL-S9-1/4-7 PD 44814-0007 1 14 21 1.845 RPSL-S9-1/4-8 PD 44814-0008 1 16 24 2.045 RPSL-S9-1/4-9 PD 44814-0009 1 18 27 2.245 RPSL-S9-1/4-10 PD 44814-0010 1 20 30 2.445 Parker Hannifin Corporation 46 47 Parker-Origa Glendale Heights, Illinois ORIGA www.parkeroriga.com 6,5 24 23x0,5 deep G3/8 25 123 83251 ORIC0C Body Ported Valves 10/2/03 9:19 AM Page 47 Catalog 0952 Valves Dimensions & Ordering Information Base Plates, ISO 5599 Size 1, 2 & 3 Dimensions (mm) Base Plates Single Base Plate, Form A Side Ported ISO 5599 A Size: 1, 2, 3 B   Single Base Plates - To VDMA 24345 Form A  Side Ported C - To VDMA 24345 Form B Bottom Ported L H O C     P Q Dimension Table (mm) ISO Size A B C D E F G H 1 84 43 1/4 10.5 21.5 10 32 98 2 95 56 3/8 14 26 13 40 112 3 119 68 1/2 17 17 18 32 136 ISO Size J K L M N O P Q 1 48 5.5 110 10.5 23.5 24 1/8 58 2 57 6.6 124 14 30 30 1/8 74 3 71 6.6 149 17 22 32 1/8 90 Order Instructions Order Number ISO Size Ports Metric Version NPT Version 1 1/4 KX 9076 600C01 3/8 642K91 2 3/8 KX 9433 601C01 1/2 643K91 3 1/2 KX 9434 602C01 3/4 644K91 Parker Hannifin Corporation 47 48 Parker-Origa Glendale Heights, Illinois ORIGA www.parkeroriga.com J G K F M D N E 83251 ORIC0C Body Ported Valves 10/2/03 9:19 AM Page 48 Catalog 0952 Valves Dimensions & Ordering Information Base & End Plates, ISO 5599 Size 1, 2 & 3 Dimensions (mm) Single Base Plate, Form B Bottom Ported N J Intermediate Plate    Form C     H M O F End Plate Set, Form D for Intermediate Plate L B B Dimension Table (mm) Order Instructions ISO Size A B C D E F H J K L M N O P Q ISO Size Ports Order Number 1 46 110 10 30 5 84 G1/8 G1/4 5.5 98 23 46 62 23 7.5 1 G1/4 KX 9077 2 56 124 13 35 6.5 95 G1/8 G3/8 6.6 112 28 56 73 27 7.5 2 G3/8 KX 9436 3 71 149 18 32 9 119 G1/8 G1/2 6.6 136 34 68 90 35 10 3 G1/2 KX 9437 Order Instructions ISO Size Description Order Number 1 manifold subbase, G1/4, Form C KX 9079 2 manifold subbase, G3/8, Form C KX 9419 3 manifold subbase, G1/2, Form C KX 9420 1 end plate set, G3/8, Form D KX 9078 2 end plate set, G1/2, Form D KX 9421 3 end plate set, G1, Form D KX 9422 adapter plate to combine size 1 to size 2 KX 9430 adapter plate to combine size 1 to size 3 KX 9432 adapter plate to combine size 2 to size 3 KX 9431 1 cover strip kit KX 9082 2 cover strip kit KX 9423 3 cover strip kit KX 9424 1 intermediate plate, with built-in flow control valves 701B77 2 intermediate plate, with built-in flow control valves 702B77 3 intermediate plate, with built-in flow control valves 722K77 1 intermediate plate, with ONE built-in pressure regulator 620C91 2 intermediate plate, with ONE built-in pressure regulator 624C91 3 intermediate plate, with ONE built-in pressure regulator 628C91 1 intermediate plate, with TWO built-in pressure regulators 621C91 2 intermediate plate, with TWO built-in pressure regulators 625C91 3 intermediate plate, with TWO built-in pressure regulators 629C91 48 Parker Hannifin Corporation 49 Parker-Origa Glendale Heights, Illinois ORIGA www.parkeroriga.com A D K K C Q K P E 83251 ORIC0C Body Ported Valves 10/2/03 9:19 AM Page 49 Catalog 0952 Valves Ordering Information Accessories & Spare Parts Accessories Exhaust Mufflers Exhaust Flow Controls Port Plugs Order Number Port Size Order Number Port Size Order Number Port Size KY 2010 G1/8 KY 6952 G1/8 0205-1000 G1/8 KY 2011 G1/4 KY 6953 G1/4 0205-1300 G1/4 KY 2012 G3/8 KY 6954 G1/2 0205-1600 G3/8 KY 2013 G1/2 ASP-1SC 1/8" NPT 0205-2000 G1/2 KY-U2010 1/8" NPT ASP-2SC 1/4" NPT 0205-1100 1/8" NPT KY-U2011 1/4" NPT 0205-1400 1/4" NPT KY-U2013 1/2" NPT 0205-1800 3/8" NPT 0205-2200 1/2" NPT Metric Conversion Fittings Order Number Port Size 2521-1/8-02 G1/8 to 1/8" NPT 2521-1/4-04 G1/4 to 1/4" NPT 2521-3/8-06 G3/8 to 3/8" NPT 2521-1/2-08 G1/2 to 1/2" NPT Spare Parts Replacement Solenoid Coils: Replacement Solenoid Coils: 1/8" & 1/4" Body Ported Valves 1/2" Body Ported Valves & ISO Valves Order Number Voltage Order Number Voltage KZ 3674 12vDC KZ 3518 12vDC KZ 3673 24vDC KZ 3519 24vDC KZ 3669 110vAC KZ 3521 110vAC KZ 3672 220vAC KZ 3522 220vAC KZ 3675 24vAC KZ 3518 24vAC Replacement DIN Connector Plugs Order Number Description KY 9393 Replacement DIN connector plug C12213N21 DIN connector plug w/1/2" NPTF conduit entry PD 34991 Solenoid retaining nut KW 0766 Lighted wafer seal, for DIN connector plug, 24vDC KZ 3759 DIN connector plug w/surge suppression, 12 & 24vDC KX 5368 DIN connector plu w/surge suppression, 110 & 220vAC KY 3018 DIN connector plug w/surge suppression, LED, 12 & 24vDC KW 0718 DIN connector plug w/surge suppression, LED, 110 & 220vAC Seal Kits: S9 Solenoid Valves Actuation 1/8" 1/4" 1/2" 5/2 Single PD 35534 PD 35536 PD 35578 5/2 Double PD 35520 PD 35526 PD 35577 5/3 Blocked PD 35525 PD 35531 PD 35579 5/3 Exhaust PD 35524 PD 35530 PD 35581 5/3 Dual PD 35523 PD 35529 PD 35580 RPS Supply Manifolds: 1/8 RPS Supply Manifolds: 1/4 PD 44813-.... PD 44814-.... Order Number Description Order Number Description 88-37H643-75 O-ring (10x2) 88-52H643-75 O-ring (13x2) ZP 3986 Screws (M3x40) ZP 3988 Screws (M4x55) 49 Parker Hannifin Corporation 50 Parker-Origa Glendale Heights, Illinois ORIGA www.parkeroriga.com Catalog 0952 Valves Notes Parker Hannifin Corporation 51 Parker-Origa Glendale Heights, Illinois ORIGA www.parkeroriga.com Catalog 0952 Valves Notes Parker Hannifin Corporation 52 Parker-Origa Glendale Heights, Illinois ORIGA www.parkeroriga.com Catalog 0952 Valves Notes Parker Hannifin Corporation 53 Parker-Origa Glendale Heights, Illinois ORIGA www.parkeroriga.com Catalog 0952 Valves Safety Guide Safety Guide For Selecting And Using Pneumatic Division Products And Related Accessories ! WARNING: FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF PNEUMATIC DIVISION PRODUCTS, ASSEM- BLIES OR RELATED ITEMS (“PRODUCTS”) CAN CAUSE DEATH, PERSONAL INJURY, AND PROPERTY DAM- AGE. POSSIBLE CONSEQUENCES OF FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THESE PRODUCTS INCLUDE BUT ARE NOT LIMITED TO: • Unintended or mistimed cycling or motion of machine members or failure to cycle • Work pieces or component parts being thrown off at high speeds. • Failure of a device to function properly for example, failure to clamp or unclamp an associated item or device. • Explosion • Suddenly moving or falling objects. • Release of toxic or otherwise injurious liquids or gasses. Before selecting or using any of these Products, it is important that you read and follow the instructions below. 1. GENERAL INSTRUCTIONS 1.1. Scope: This safety guide is designed to cover general guidelines on the installation, use, and maintenance of Pneumatic Division Valves, FRLs (Filters, Pressure Regulators, and Lubricators), Vacuum products and related accessory components. 1.2. Fail-Safe: Valves, FRLs, Vacuum products and their related components can and do fail without warning for many reasons. Design all systems and equipment in a fail-safe mode, so that failure of associated valves, FRLs or Vacuum products will not endanger persons or property. 1.3 Relevant International Standards: For a good guide to the application of a broad spectrum of pneumatic fluid power devices see: ISO 4414:1998, Pneumatic Fluid Power – General Rules Relating to Systems. See www.iso.org for ordering information. 1.4. Distribution: Provide a copy of this safety guide to each person that is responsible for selection, installation, or use of Valves, FRLs or Vacuum products. Do not select, or use Parker valves, FRLs or vacuum products without thoroughly reading and understanding this safety guide as well as the specific Parker publications for the products considered or selected. 1.5. User Responsibility: Due to the wide variety of operating conditions and applications for valves, FRLs, and vacuum products Parker and its distributors do not represent or warrant that any particular valve, FRL or vacuum product is suitable for any specific end use system. This safety guide does not analyze all technical parameters that must be considered in selecting a product. The user, through its own analysis and testing, is solely responsible for: • Making the final selection of the appropriate valve, FRL, Vacuum component, or accessory. • Assuring that all user’s performance, endurance, maintenance, safety, and warning requirements are met and that the application presents no health or safety hazards. • Complying with all existing warning labels and / or providing all appropriate health and safety warnings on the equipment on which the valves, FRLs or Vacuum products are used; and, • Assuring compliance with all applicable government and industry standards. 1.6. Safety Devices: Safety devices should not be removed, or defeated. 1.7. Warning Labels: Warning labels should not be removed, painted over or otherwise obscured. 1.8. Additional Questions: Call the appropriate Parker technical service department if you have any questions or require any additional information. See the Parker publication for the product being considered or used, or call 1-800-CPARKER, or go to www.parker.com, for telephone numbers of the appropriate technical service department. 2. PRODUCT SELECTION INSTRUCTIONS 2.1. Flow Rate: The flow rate requirements of a system are frequently the primary consideration when designing any pneumatic system. System components need to be able to provide adequate flow and pressure for the desired application. 2.2. Pressure Rating: Never exceed the rated pressure of a product. Consult product labeling, Pneumatic Division catalogs or the instruction sheets supplied for maximum pressure ratings. 2.3. Temperature Rating: Never exceed the temperature rating of a product. Excessive heat can shorten the life expectancy of a product and result in complete product failure. 2.4. Environment: Many environmental conditions can affect the integrity and suitability of a product for a given application. Pneumatic Division products are designed for use in general purpose industrial applications. If these products are to be used in unusual circumstances such as direct sunlight and/or corrosive or caustic environments, such use can shorten the useful life and lead to premature failure of a product. 2.5. Lubrication and Compressor Carryover: Some modern synthetic oils can and will attack nitrile seals. If there is any possibility of synthetic oils or greases migrating into the pneumatic components check for compatibility with the seal materials used. Consult the factory or product literature for materials of construction. 2.6. Polycarbonate Bowls and Sight Glasses: To avoid potential polycarbonate bowl failures: • Do not locate polycarbonate bowls or sight glasses in areas where they could be subject to direct sunlight, impact blow, or temperatures outside of the rated range. • Do not expose or clean polycarbonate bowls with detergents, chlorinated hydro-carbons, keytones, esters or certain alcohols. • Do not use polycarbonate bowls or sight glasses in air systems where compressors are lubricated with fire resistant fluids such as phosphate ester and di-ester lubricants. Parker Hannifin Corporation 54 Parker-Origa Glendale Heights, Illinois ORIGA www.parkeroriga.com Catalog 0952 Valves Safety Guide 2.7. Chemical Compatibility: For more information on plastic component chemical compatibility see Pneumatic Division technical bulletins Tec-3, Tec-4, and Tec-5 2.8. Product Rupture: Product rupture can cause death, serious personal injury, and property damage. • Do not connect pressure regulators or other Pneumatic Division products to bottled gas cylinders. • Do not exceed the maximum primary pressure rating of any pressure regulator or any system component. • Consult product labeling or product literature for pressure rating limitations. 3. PRODUCT ASSEMBLY AND INSTALLATION INSTRUCTIONS 3.1. Component Inspection: Prior to assembly or installation a careful examination of the valves, FRLs or vacuum products must be performed. All components must be checked for correct style, size, and catalog number. DO NOT use any component that displays any signs of nonconformance. 3.2. Installation Instructions: Parker published Installation Instructions must be followed for installation of Parker valves, FRLs and vacuum components. These instructions are provided with every Parker valve or FRL sold, or by calling 1-800-CPARKER, or at www.parker.com. 3.3. Air Supply: The air supply or control medium supplied to Valves, FRLs and Vacuum components must be moisture-free if ambient temperature can drop below freezing 4. VALVE AND FRL MAINTENANCE AND REPLACEMENT INSTRUCTIONS 4.1. Maintenance: Even with proper selection and installation, valve, FRL and vacuum products service life may be significantly reduced without a continuing maintenance program. The severity of the application, risk potential from a component failure, and experience with any known failures in the application or in similar applications should determine the frequency of inspections and the servicing or replacement of Pneumatic Division products so that products are replaced before any failure occurs. A maintenance program must be established and followed by the user and, at minimum, must include instructions 4.2 through 4.10. 4.2. Installation and Service Instructions: Before attempting to service or replace any worn or damaged parts consult the appropriate Service Bulletin for the valve or FRL in question for the appropriate practices to service the unit in question. These Service and Installation Instructions are provided with every Parker valve and FRL sold, or are available by calling 1-800-CPARKER, or by accessing the Parker web site at www.parker.com. 4.3. Lockout / Tagout Procedures: Be sure to follow all required lockout and tagout procedures when servicing equipment. For more information see: OSHA Standard – 29 CFR, Part 1910.147, Appendix A, The Control of Hazardous Energy – (Lockout / Tagout) 4.4. Visual Inspection: Any of the following conditions requires immediate system shut down and replacement of worn or damaged components: • Air leakage: Look and listen to see if there are any signs of visual damage to any of the components in the system. Leakage is an indication of worn or damaged components. • Damaged or degraded components: Look to see if there are any visible signs of wear or component degradation. • Kinked, crushed, or damaged hoses. Kinked hoses can result in restricted air flow and lead to unpredictable system behavior. • Any observed improper system or component function: Immediately shut down the system and correct malfunction. • Excessive dirt build-up: Dirt and clutter can mask potentially hazardous situations. Caution: Leak detection solutions should be rinsed off after use. 4.5. Routine Maintenance Issues: • Remove excessive dirt, grime and clutter from work areas. • Make sure all required guards and shields are in place. 4.6. Functional Test: Before initiating automatic operation, operate the system manually to make sure all required functions operate properly and safely. 4.7. Service or Replacement Intervals: It is the user’s responsibility to establish appropriate service intervals. Valves, FRLs and vacuum products contain components that age, harden, wear, and otherwise deteriorate over time. Environmental conditions can significantly accelerate this process. Valves, FRLs and vacuum components need to be serviced or replaced on routine intervals. Service intervals need to be established based on: • Previous performance experiences. • Government and / or industrial standards. • When failures could result in unacceptable down time, equipment damage or personal injury risk. 4.8. Servicing or Replacing of any Worn or Damaged Parts: To avoid unpredictable system behavior that can cause death, personal injury and property damage: • Follow all government, state and local safety and servicing practices prior to service including but not limited to all OSHA Lockout Tagout procedures (OSHA Standard – 29 CFR, Part 1910.147, Appendix A, The Control of Hazardous Energy – Lockout / Tagout). • Disconnect electrical supply (when necessary) before installation, servicing, or conversion. • Disconnect air supply and depressurize all air lines connected to system and Pneumatic Division products before installation, service, or conversion. • Installation, servicing, and / or conversion of these products must be performed by knowledgeable personnel who understand how pneumatic products are to be applied. • After installation, servicing, or conversions air and electrical supplies (when necessary) should be connected and the product tested for proper function and leakage. If audible leakage is present, or if the product does not operate properly, do not put product or system into use. • Warnings and specifications on the product should not be covered or painted over. If masking is not possible, contact your local representative for replacement labels. 4.9. Putting Serviced System Back into Operation: Follow the guidelines above and all relevant Installation and Maintenance Instructions supplied with the valve FRL or vacuum component to insure proper function of the system. Parker Hannifin Corporation 55 Parker-Origa Glendale Heights, Illinois ORIGA www.parkeroriga.com Catalog 0952 Valves Offer of Sale Offer of Sale The items described in this document and other documents or descriptions provided by Parker Hannifin Corporation, its subsidiaries and Divisions (“Company”) and its authorized distributors, are hereby offered for sale at prices to be established by the Company, its subsidiaries and its authorized distributors. This offer and its acceptance by any customer (“Buyer”) shall be governed by all of the following Terms and Conditions. Buyer’s order for any such item, when communicated to the Company, its subsidiary or an authorized distributor (“Seller”) verbally or in writing, shall constitute acceptance of this offer. discard or otherwise dispose of any special tooling or other property in its 1. Terms and Conditions of Sale: All descriptions, quotations, proposals, sole discretion at any time. offers, acknowledgments, acceptances and sales of Seller’s products are subject to and shall be governed exclusively by the terms and conditions 8. Buyer’s Property: Any designs, tools, patterns, materials, drawings, stated herein. Buyer’s acceptance of any offer to sell is limited to these terms confidential information or equipment furnished by Buyer, or any other and conditions. Any terms or conditions in addition to, or inconsistent with items which become Buyer’s property, may be considered obsolete and those stated herein, proposed by Buyer in any acceptance of an offer by may be destroyed by Seller after two (2) consecutive years have elapsed Seller, are hereby objected to. No such additional, different or inconsistent without Buyer placing an order for the items which are manufactured using terms and conditions shall become part of the contract between Buyer and such property. Seller shall not be responsible for any loss or damage to Seller unless expressly accepted in writing by Seller. Seller’s acceptance such property while it is in Seller’s possession or control. of any offer to purchase by Buyer is expressly conditional upon Buyer’s 9. Taxes: Unless otherwise indicated on the face hereof, all prices and assent to all the terms and conditions stated herein, including any terms in charges are exclusive of excise, sales, use, property, occupational or like addition to, or inconsistent with those contained in Buyer’s offer. Acceptance taxes which may be imposed by any taxing authority upon the manufacture, of Seller’s products shall in all events constitute such assent. sale or delivery of the items sold hereunder. If any such taxes must be 2. Payment: Payment shall be made by Buyer net 30 days from the date of paid by Seller or if Seller is liable for the collection of such tax, the amount delivery of the items purchased hereunder. Amounts not timely paid shall thereof shall be in addition to the amounts for the items sold. Buyer agrees bear interest at the maximum rate permitted by law for each month or portion to pay all such taxes or to reimburse Seller therefore upon receipt of its thereof that the Buyer is late in making payment. Any claims by Buyer for invoice. If Buyer claims exemption from any sales, use or other tax imposed omissions or shortages in a shipment shall be waived unless Seller receives by any taxing authority, Buyer shall save Seller harmless from and against notice thereof within 30 days after Buyer’s receipt of the shipment. any such tax, together with any interest or penalties thereon which may be assessed if the items are held to be taxable. 3. Delivery: Unless otherwise provided on the face hereof, delivery shall be made F.O.B. Seller’s plant. Regardless of the method of delivery, 10. Indemnity For Infringement of Intellectual Property Rights: Seller however, risk of loss shall pass to Buyer upon Seller’s delivery to a carrier. shall have no liability for infringement of any patents, trademarks, copyrights, Any delivery dates shown are approximate only and Seller shall have no trade dress, trade secrets or similar rights except as provided in this Part 10. liability for any delays in delivery. Seller will defend and indemnify Buyer against allegations of infringement of U.S. patents, U.S. trademarks, copyrights, trade dress and trade secrets 4. Warranty: Seller warrants that the items sold hereunder shall be free (hereinafter “Intellectual Property Rights”). Seller will defend at its expense from defects in material or workmanship for a period of 18 months from and will pay the cost of any settlement or damages awarded in an action date of shipment from the Company. THIS WARRANTY COMPRISES brought against Buyer based on an allegation that an item sold pursuant THE SOLE AND ENTIRE WARRANTY PERTAINING TO ITEMS to this contract infringes the Intellectual Property Rights of a third party. PROVIDED HEREUNDER. SELLER MAKES NO OTHER WARRANTY, Seller’s obligation to defend and indemnify Buyer is contingent on Buyer GUARANTEE, OR REPRESENTATION OF ANY KIND WHATSOEVER. notifying Seller within ten (10) days after Buyer becomes aware of such ALL OTHER WARRANTIES, INCLUDING BUT NOT LIMITED TO, allegations of infringement, and Seller having sole control over the defense MERCHANTABILITY AND FITNESS FOR PURPOSE, WHETHER of any allegations or actions including all negotiations for settlement or EXPRESS, IMPLIED, OR ARISING BY OPERATION OF LAW, TRADE compromise. If an item sold hereunder is subject to a claim that it infringes USAGE, OR COURSE OF DEALING ARE HEREBY DISCLAIMED. the Intellectual Property Rights of a third party, Seller may, at its sole NOTWITHSTANDING THE FOREGOING, THERE ARE NO WARRANTIES expense and option, procure for Buyer the right to continue using said WHATSOEVER ON ITEMS BUILT OR ACQUIRED WHOLLY OR item, replace or modify said item so as to make it noninfringing, or offer to PARTIALLY, TO BUYER’S DESIGN OR SPECIFICATIONS. accept return of said item and return the purchase price less a reasonable allowance for depreciation. Notwithstanding the foregoing, Seller shall 5. Limitation of Remedy: SELLER’S LIABILITY ARISING FROM OR IN have no liability for claims of infringement based on information provided ANY WAY CONNECTED WITH THE ITEMS SOLD OR THIS CONTRACT by Buyer, or directed to items delivered hereunder for which the designs SHALL BE LIMITED EXCLUSIVELY TO REPAIR OR REPLACEMENT are specified in whole or part by Buyer, or infringements resulting from the OF THE ITEMS SOLD OR REFUND OF THE PURCHASE PRICE PAID modification, combination or use in a system of any item sold hereunder. BY BUYER, AT SELLER’S SOLE OPTION. IN NO EVENT SHALL The foregoing provisions of this Part 10 shall constitute Seller’s sole and SELLER BE LIABLE FOR ANY INCIDENTAL, CONSEQUENTIAL OR exclusive liability and Buyer’s sole and exclusive remedy for infringement SPECIAL DAMAGES OF ANY KIND OR NATURE WHATSOEVER, of Intellectual Property Rights. INCLUDING BUT NOT LIMITED TO LOST PROFITS ARISING FROM OR IN ANY WAY CONNECTED WITH THIS AGREEMENT OR ITEMS If a claim is based on information provided by Buyer or if the design for an SOLD HEREUNDER, WHETHER ALLEGED TO ARISE FROM BREACH item delivered hereunder is specified in whole or in part by Buyer, Buyer OF CONTRACT, EXPRESS OR IMPLIED WARRANTY, OR IN TORT, shall defend and indemnify Seller for all costs, expenses or judgements INCLUDING WITHOUT LIMITATION, NEGLIGENCE, FAILURE TO WARN resulting from any claim that such item infringes any patent, trademark, OR STRICT LIABILITY. copyright, trade dress, trade secret or any similar right. 6. Changes, Reschedules and Cancellations: Buyer may request to modify 11. Force Majeure: Seller does not assume the risk of and shall not be the designs or specifications for the items sold hereunder as well as the liable for delay or failure to perform any of Seller’s obligations by reason quantities and delivery dates thereof, or may request to cancel all or part of circumstances beyond the reasonable control of Seller (hereinafter of this order, however, no such requested modification or cancellation shall “Events of Force Majeure”). Events of Force Majeure shall include without become part of the contract between Buyer and Seller unless accepted by limitation, accidents, acts of God, strikes or labor disputes, acts, laws, rules Seller in a written amendment to this Agreement. Acceptance of any such or regulations of any government or government agency, fires, floods, delays requested modification or cancellation shall be at Seller’s discretion, and or failures in delivery of carriers or suppliers, shortages of materials and shall be upon such terms and conditions as Seller may require. any other cause beyond Seller’s control. 7. Special Tooling: A tooling charge may be imposed for any special 12. Entire Agreement/Governing Law: The terms and conditions set tooling, including without limitations, dies, fixtures, molds and patterns, forth herein, together with any amendments, modifications and any acquired to manufacture items sold pursuant to this contract. Such special different terms or conditions expressly accepted by Seller in writing, shall tooling shall be and remain Seller’s property notwithstanding payment constitute the entire Agreement concerning the items sold, and there are of any charges by Buyer. In no event will Buyer acquire any interest in no oral or other representations or agreements which pertain thereto. apparatus belonging to Seller which is utilized in the manufacture of the This Agreement shall be governed in all respects by the law of the State items sold hereunder, even if such apparatus has been specially converted of Ohio. No actions arising out of sale of the items sold hereunder or this or adapted for such manufacture and notwithstanding any charges paid Agreement may be brought by either party more than two (2) years after by Buyer. Unless otherwise agreed, Seller shall have the right to alter, the cause of action accrues. ©®2008 Parker Hannifin Corporation Printed in U.S.A. December, 2008 Parker Hannifin Corporation 56 Parker-Origa Glendale Heights, Illinois ORIGA www.parkeroriga.com Catalog 0952 12/2008 Parker Hannifin Corporation Phone 630-871-8300 Parker-Origa fax 630-871-1515 100 West Lake Drive toll free 800-695-5984 Glendale Heights, IL 60139 USA email: info-hous-market@parker.com website www.parkeroriga.com ORIGA

Frequently asked questions

What makes Elite.Parts unique?

chervon down
At GID Industrial (Elite.Parts' parent company), we specialize in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

What kind of warranty will the PD 40664 have?

chervon down
Warranties differ by part and by which suppliers we use to procure it for you. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carriers does Elite.Parts work with?

chervon down
Elite.Parts can ship via FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Will Elite.Parts sell to me even though I live outside the USA?

chervon down
Absolutely! We are happy to serve customers regardless of location. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

I have a preferred payment method. Will Elite.Parts accept it?

chervon down
All major credit cards are accepted: Visa, MasterCard, Discover, and American Express. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

ACTUATOR 120PSI MAX

ACTUATOR 125PSI MAX

AIR CYLINDER DOUBLE ACTUATING

AIR CYLINDER DOUBLE ACTUATING

AIR CYLINDER DOUBLE ACTUATING

AIR CYLINDER DOUBLE ACTUATING