Ambient air temperature
-13 to +158 (–25 to +70). Storage: –40 to +158 (–40 to +70)
Conformity to standards
IEC/EN 60947-5-1, UL 508, CSA C22-2 n° 14
Connection
min: 1 x 0.2 mm2, max: 2 x 2.5 mm 2
Datasheet
Extracted Text
Industrial Pressure Switches and Vacuum Switches Catalog 9012CT9701R04/09 2009 9012G, 9016G, and XMLA, B, C, D Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Industrial Pressure Switches Table of Contents Selection Guide......................................................................................................................4 Terminology............................................................................................................................6 Selecting a Pressure Switch...................................................................................................8 XML Electromechanical Pressure Switches.........................................................................10 Specifications ................................................................................................................................. 11 Interpretation of the Catalog Number............................................................................................. 20 Dimensions..................................................................................................................................... 74 Accessories and Renewal Parts..................................................................................................... 73 9012G Pressure Switches....................................................................................................79 Specifications ................................................................................................................................. 83 Interpretation of the Catalog Number............................................................................................. 84 Modifications, Accessories, and Renewal Parts............................................................................. 91 Dimensions..................................................................................................................................... 96 9016G Vacuum Switches .....................................................................................................94 Specifications ................................................................................................................................. 83 Interpretation of the Catalog Number............................................................................................. 84 Modifications, Accessories, and Renewal Parts............................................................................. 99 Dimensions..................................................................................................................................... 99 3 © 1998–2009 Schneider Electric 10/2009 All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Selection Guide Industrial Pressure Switches XML Electromechanical Pressure Switches Type of installation Control circuits Media controlled Air, water, hydraulic oils, corrosive fluids, viscous products Applications Fixed differential: Adjustable differential: Dual-stage switches: Type of operation Detection of a Regulation between Fixed differential, single threshold two thresholds detection at each threshold Air, fresh water, sea water, corrosive fluids, viscous products, up to 320 °F (160 °C) Fluid characteristics depending on model Size (pressure range) –1 to 500 bar (–14.5 to 7250 psi) Dimensions of case (mm) 35 x 68 x 75 46 x 68 x 85 35 x 68 x 75 width x height x depth 2 C/O single-pole, Type of contacts 1 C/O single-pole, snap action 1 C/O single-pole, snap action simultaneous, snap action IP 66 with terminal connections IP 66 with terminal IP 66 with terminal connections Degree of protection IP 65 with plug-in connector connections IP 65 with plug-in connector Agency listings UL, CSA, CCC, BV, LROS, RINA, GL, DNV, VIT-SEPRO Screw terminals: 1 tapped entry: 1/2 NPT; M20 x 1.5 mm for ISO conduit/cable; or PG 13.5 conduit/cable entry Electrical connection Connector: DIN 43650, M12 G 1⁄4 (BSP female) Pressure connection G 1-1⁄4” (BSP female) for viscous products Catalog number XMLA XMLB XMLC XMLD Pages pages 10–78 For electromechanical pressure and vacuum switches with alternative tapped cable or fluid entries, consult your local Other versions sales office. 4 10/2009 © 1998–2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Selection Guide Industrial Pressure Switches 9012G Pressure and 9016G Vacuum Switches Type of Control circuits Power circuits installation Media (1) Air, water, hydraulic oils, gases, steam controlled Applications Adjustable Differential- Dual-stage Fixed differential: differential: Pressure switches: Type of Vacuum switches Vacuum switches Detection of a Regulation (change in the Fixed differential, for control circuits for power circuits operation single threshold between difference between detection at each two thresholds two pressures) threshold Fluid characteristics up to 248 °F (120 °C) Diaphragm: 0.2-675 psi on falling pressure Size (pressure range) 0–28.7 inHg 0–25 inHg Piston actuated: 20-9,000 psi on falling pressure Dimensions of case (mm) See “Dimensions” beginning on page 96. Width x height x depth DPST Type of contacts SPDT or DPDT double break contacts (SPDT for Form H) Degree of protection IP 66 conforming to IEC 60957 Agency listings UL Listed and CSA Certified as industrial control equipment Electrical connection 1/2”-14 NPTF, PG13.5, or ISO M20; 3/4”-14 NPTF available only on NEMA 7 and 9. 3 x 1/2” conduit 1/2"-14 NPT NEMA 1 is 1/2” conduit entry, unthreaded. entry, unthreaded (enclosed devices) Pressure connection G1/4 (BSP) female, 1/4" NPTF, 1/4-18 NPT internal or external (depending on model), 1/2”-14 NPT 9012GD, GE, 9012GA, GB, 9012GGW, 9012GKW, Catalog number 9016GAW, GAR 9016GVG GF, GR, GS, GT GC, GN, GP, GQ GHW, GJW GLW, GMW Pages pages 85–92 pages 87–93 page 89 page 90 page 94 page 95 Other versions — 1. The hydraulic fluids used for laboratory testing are equivalent to SAE 30 W oils. If oils have less viscosity than this type of oil, leakage can be expected. Schneider Electric does not have test data to support or predict fluid bypass with oils less than SAE 30W. 5 © 1998–2009 Schneider Electric 10/2009 All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Introduction Industrial Pressure Switches Terminology Terminology Operating Range The difference between the minimum decreasing-pressure low point (PB) and the maximum increasing-pressure high point (PH) setting values. Size Pressure switches and vacuum-pressure switches Maximum value of the operating range. Vacuum switches Minimum value of the operating range. Operating Point on Rising Pressure (PH) Pressure switches The upper pressure setting at which the pressure switch actuates the contacts on rising pressure. Vacuum switches The lower vacuum setting at which the vacuum switch resets the contacts on rising vacuum. Operating Point on Falling Pressure (PB) The pressure at which the switch output changes state on falling pressure. Switches with fixed differential Depending on the switch, either the high or low operating point is adjustable, and the other operating point follows. The window is fixed. Switches with adjustable differential An adjustable differential allows independent setting of both operating points. Differential The difference between the operating point on rising pressure (PH) and the operating point on falling pressure (PB). Spread For dual-stage switches, the spread indicates the difference between the two operating points on rising pressure (PH2 and PH1) and, for vacuum switches, the difference between the two operating points on falling pressure (PB2 and PB1). Differential-Pressure Sensing Switches for differential-pressure sensing measure the difference between two pressures. 6 10/2009 © 1998–2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Introduction Industrial Pressure Switches Terminology Accuracy (switches with setting scale) + The tolerance between the point at which the switch actuates its Setting point contacts and the value indicated on the setting scale. Where very – high setting accuracy is required (initial installation of the product), it is recommended to use separate measuring equipment (pressure gauge, etc.). Repeat Accuracy (R) The tolerance between two consecutive switching operations R Drift (F) The tolerance of the operating point throughout the entire service life F of the switch. Maximum Allowable Pressure bar 300 The maximum value of an accidental pressure surge of very short duration (a few milliseconds). 200 100 0 0 50 100 150 ms Example 1: With destructive (burst) pressure level bar Without damping device 100 With damping device 50 0 0 50 100 150 ms Example 2: With destructive (burst) pressure level and destructive pressure oscillations Maximum allowable pressure per cycle (Ps) The maximum pressure level per cycle that the switch can withstand for optimum service life. Surge A surge is a high rate of rise in pressure, normally of short duration, caused by starting a pump or by opening and closing a valve. Depending on frequency and duration, surge can reduce service life. Extremely high rates of rise in pressure can be damaging even if they are within the limits of the maximum allowable pressure. Destruction pressure Also called burst pressure, the destruction pressure is the maximum rated pressure that the switch can withstand before its destruction—for instance, through rupturing or component failure. 7 © 1998–2009 Schneider Electric 10/2009 All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Introduction Industrial Pressure Switches Selecting a Pressure Switch Selecting a Pressure Switch Catalog Choose 1 2 3 4 5 6 7 8 9 10 : > >>>> > >>>> Number Setpoints Fluids Pressure Surges Enclosure Output Electrical Fluid Special System Features Range Connection Connection Response Time 1 The deciding factors in the selection of a pressure switch for use on control circuits depend on the requirements of the application. Consider the following requirements to help determine the appropriate catalog number for your application. 1. Setpoints: Do you want to control/monitor one setpoint or two? Fixed differentialOne setpoint: fixed differentialTwo setpoints: adjustable differential 2. Fluids: What fluids do you want to control? PH Hydraulic oil, air, fresh water ≤ 70 °CSteam Hydraulic oil, air, fresh water ≤ 160 °CCorrosive fluid ≤ 160 °C Sea water ≤ 70 °CViscous fluid ≤ 160 °C Sea water ≤ 160 °C Adjustable differential Ensure that the wetted parts of the switch are compatible with the system fluid. 3. Pressure Range: What pressure range does the system experience? PH Note: Select pressure settings that fall within the middle 80% of the pressure range. The pressure PB applied during a normal cycle should never exceed the maximum range value listed for the switch. Pressure surges should be less than the maximum allowable pressure listed for the switch. Rated Pressure (1) XML 9012G / 9016 G psi bar psi bar 0 to 0.725 0 to 0.05 0.2 to 10 0.01 to 0.69 0 to 5.075 0 to 0.35 1 to 40 0.07 to 2.76 −14.5 to −4.06 −1 to −0.28 1.5 to 75 0.10 to 5.17 −14.5 to −2.03 −1 to −0.14 3 to 150 0.21 to 10.34 −2.9 to −0.029 −0.2 to −0.02 5 to 250 0.34 to 17.24 −7.25 to 72.5 −0.5 to 5 13 to 425 0.90 to 29.30 0 to 14.5 0 to 1 20 to 675 1.38 to 46.54 0 to 36.25 0 to 2.5 0 to 75 0 to 5.17 0 to 58 0 to 4 0 to 175 0 to 12.07 0 to 145 0 to 10 0 to 500 0 to 34.47 0 to 290 0 to 20 20 to 1000 1.38 to 68.95 0 to 507.5 0 to 35 90 to 2900 6.21 to 199.95 0 to 580 0 to 40 170 to 5600 11.72 to 386.11 0 to 1015 0 to 70 270 to 9000 18.62 to 620.53 0 to 2320 0 to 160 0 to 5000 0 to 344.74 0 to 4350 0 to 300 0 to 28 inHg 0 to 25 inHg 0 to 7250 0 to 500 5 to 25 inHg (9016GVG only) (1) For 9016G vacuum switches, the unit of rated pressure is inHg. 4. Surges: How frequent are surges in your system, and what is their maximum pressure level? Applications experiencing frequent or high-pressure surges may require a device with a higher pressure range. 1 For switches used on power circuits, see catalog 9013CT9701, Commercial Pressure Switches, Class 9013 Types F and G. 8 10/2009 © 1998–2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Introduction Industrial Pressure Switches Selecting a Pressure Switch 5. Enclosure: What type of enclosure do you need? Open styleNEMA Type 7, 9 NEMA Type 1NEMA Type 4, 4X, 13 / IP66, IP65 6. Output: What output type do you require? SPDT contacts, 1 N/O, 1 N/CDual stage, 1 SPDT contact each stage, 1 N/O, 1 N/C 2 SPDT contacts, 1 N/O, 1 N/CHorsepower rated, 9016GVG vacuum switch only 7. Electrical Connection: What type of electrical connection do you require? ½"- 14 NPTF¾"-14 NPTF (available only on NEMA 7 & 9) ISO M20 metric threadsNo threaded connection (open style or NEMA 1 only) Type 13 (PG 13.5) metric threads 8. Pressure Connection: What type of pressure connection do you require? ¼"- 18 NPTF (female)PT ¼ (JIS B0203) ½" - 14 NPT7/16"-20 UNF-2B G 1/4 BSP (female) metric thread 9. Special Features: Do you require any special features? See Table 78 on page 91. When switches must be factory set and only one setting is identified, specify whether this setting is on rising or falling pressure. See Table 78 on page 91 of the catalog for available modifications for 9012 and 9016G Pressure Switches. (Form designations are added to the end of the part number of the standard device for these products.) Some examples are: Pilot light Prewired receptacles External range adjustment Range scale window Special factory pressure settings Pressure Connections 10. System response time If system response time is critical, select a switch with a volumetric displacement that is compatible with the overall system. See Table 1. Table 1: Volumetric Displacement of 9012G Pressure Switches (1) (1) Volumetric Displacement Volumetric Displacement Class 9012 Type 3 3 (in ) (cm ) GAR, GAW, GDR, GDW-1& 21 0.20774 3.40422 GAR, GAW, GDR, GDW-2 & 22 0.07040 1.15385 GAR, GAW, GDR, GDW-4 & 24 0.04320 0.70805 GAR, GAW, GDR, GDW-5 & 25 0.02144 0.35140 GAR, GAW, GDR, GDW-6 & 26 0.01376 0.22553 GBR, GBW, GER, GEW-1 & 21 0.00200 0.13112 GBR, GBW, GER, GEW-2 & 22 0.00512 0.08392 GCR, GCW, GFR, GFW-1 & 21 0.00320 0.05245 GCR, GCW, GFR, GFW-2 & 22 0.00117 0.01922 GCR, GCW, GFR, GFW-3 & 23 0.00060 0.00924 GCR, GCW, GFR, GFW-4 & 24 0.00037 0.00612 (1) Figures shown are total displacement. When switch is operated between settings only, displacement is 1/3 of the values shown. 9 © 1998–2009 Schneider Electric 10/2009 All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Introduction Industrial Pressure Switches XML Electromechanical Pressure Switches XML Electromechanical Pressure Switches Introduction XML pressure and vacuum switches for control circuits are used to control the pressure of hydraulic oils, fresh water, sea water, air, steam, corrosive fluids, or viscous products, up to 7250 psi (500 bar). XMLA pressure and vacuum switches have a fixed differential and are for detection of a single threshold. They incorporate a 1 C/O single-pole contact. XMLB pressure and vacuum switches have an adjustable differential and are for regulation XMLA between two thresholds. They incorporate a 1 C/O single-pole contact. 1XMLC pressure and vacuum switches have an adjustable differential and are for regulation between two thresholds. They incorporate two C/O single-pole contacts. XMLD pressure and vacuum switches are dual-stage switches, each stage with a fixed differential, and are for detection at each threshold. They incorporate two C/O single-pole contacts (one per stage). Setting XMLA: Pressure and vacuum switches with fixed differential Rising pressure—Operating point PH is set by adjusting the red screw (1). Falling pressure—Operating point PB is not adjustable. The difference between the trip and reset points of the contact is the inherent differential of the switch XMLB, C (contact differential, friction, etc.). 1 2 XMLB and XMLC: Pressure and vacuum switches with adjustable differential When setting the pressure and vacuum switches, first adjust the operating point on rising pressure (PH), then the operating point on falling pressure (PB). Rising pressure—Operating point PH is set by adjusting the red screw (1). Falling pressure—Operating point PB is set by adjusting the green screw (2). XMLD: Dual-stage pressure and vacuum switches with fixed differential for each threshold Operating point on rising pressure of stage 1 and stage 2 First stage operating point on rising pressure (PH1) is set by adjusting the red screw (1). XMLD Second stage operating point on rising pressure (PH2) is set by adjusting the blue screw (2). 1 2 Operating point on falling pressure The operating points on falling pressure (PB1 and PB2) are not adjustable. The difference between the trip and reset points of each contact is the inherent differential of the switch (such as contact differential or friction). 10 10/2009 © 1998–2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Introduction Industrial Pressure Switches XML Electromechanical Pressure Switches Table 2: Environmental specifications Conformity to standards e, IEC/EN 60947-5-1, UL 508, CSA C22-2 n° 14 UL, CSA, CCC, BV, LROS, RINA, GL, DNV, VIT-SEPRO Product certifications Protective treatment Standard version “TC”. Special version “TH” Ambient air temperature, °F (°C) For operation: –13 to +158 (–25 to +70). Storage: –40 to +158 (–40 to +70) Hydraulic oils, air, fresh water, sea water, 32–320 °F (0 to 160 °C), depending on model Fluids or products controlled Steam, corrosive fluids, viscous products, 32–320 °F (0 to 160 °C), depending on model Case: zinc alloy. Component materials in contact with fluid: see pages 77–78 Materials Operating position All positions 4 gn (30...500 Hz) conforming to IEC 68-2-6 Vibration resistance except XML•L35••••, XML•001•••••and XMLBM03•••••: 2 gn Shock resistance 50 gn conforming to IEC 68-2-27 except XML•L35•••••, XML•001••••• and XMLBM03••••: 30 gn Class I conforming to IEC 1140, IEC 536 and NF C 20-030 Electric shock protection Screw terminal models: IP 66 conforming to IEC/EN 60529 Degree of protection Connector models: IP 65 conforming to IEC/EN 60529 Piston version switches: up to 60 cycles/minute for temperatures greater than 32 °F (0 °C) Operating rate (operating cycles/minute) Diaphragm version switches: up to 120 cycles/minute for temperatures greater than 32 °F (0 °C), Repeat accuracy < 2% • G 1/4 (BSP female) conforming to NF E 03-005, ISO 228 (1) Pressure connection • 1/4" NPTF female • PT 1/4 (JIS B0203). • 1/2" NPT electrical connections (1) Electrical Connection • ISO M20 x 1.5 tapped entry • DIN Pg 13.5 (n° 13) tapped entry for screw terminal models • Connector models, either M12 or DIN 43650 A: consult your local sales office. (1) See page 20, “Interpretation of the Catalog Number for XML Devices,” for more information on specifying the electrical and pressure connections. Table 3: Contact block specifications a AC-15; B300 (Ue = 240 V, Ie = 1.5 A - Ue = 120 V, Ie = 3 A) Rated operational specifications c DC-13; R300 (Ue = 250 V, Ie = 0.1 A) conforming to IEC 947-5-1 Appendix A, EN 60 947-5-1 Ui = 500 V conforming to IEC/EN 60947-1 Rated insulation voltage Ui = 300 V conforming to UL 508, CSA C22-2 n° 14 Rated impulse withstand voltage U imp = 6 kV conforming to IEC/EN 60947-1 XMLA and XMLB: 1 C/O single-pole contact (4 terminal), snap action Type of contacts XMLC: 2 C/O single-pole contacts (8 terminal), simultaneous, snap action Silver tipped contacts XMLD: 2 C/O single-pole contacts (8 terminal), staggered, snap action Resistance across terminals (m) < 25 conforming to NF C 93-050 method A or IEC 255-7 category 3 Terminal referencing Conforming to CENELEC EN 50013 Short-circuit protection 10 A cartridge fuse type gG (gl) 2 2 Connection Screw clamp terminals. Clamping capacity, min: 1 x 0.2 mm , max: 2 x 2.5 mm Electrical durability XMLA and XMLB XMLC and XMLD AC supply a 50/60 Hz AC supply a 50/60 Hz Conforming to IEC/EN 60947-5-1 Appendix C o Inductive circuit, lthe = 10 A o Inductive circuit, lthe = 10 A Utilisation categories AC-15 and DC-13 5 7 Ithe 4 Ithe 5 3 4 12/24 V 3 2 2 230V 48 V 48 V 1 Operating rate: 3600 operating 1 cycles/hour 0.5 0.5 Load factor: 0.5 110 V 230V 0.2 110 V 0.1 0.1 0.5 1 2 3 4 5 10 0.3 0.5 1 2 5 10 20 Current in A Current in A DC supply c DC supply c Power broken in W for 1 million operating cycles Power broken in W for 5 million operating cycles Voltage V 24 48 120 Voltage V 24 48 120 o W 312926 o W10 7 4 11 © 1998–2009 Schneider Electric 10/2009 All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Millions of operating cycles Millions of operating cycles Introduction Industrial Pressure Switches XML Electromechanical Pressure Switches Function Pressure and vacuum switches control or regulate pressure or vacuum levels in hydraulic or pneumatic systems. They transform the pressure change into a digital electrical signal when the preset operating points are reached. Switches for control circuits Switches with control-duty rated electrical contacts, designed for control of contactors, relays, power valves, PLC inputs, etc. Switches for power circuits Switches with power electrical contacts (1, 2, or 3 pole) designed for direct switching of single-phase or three-phase motors (pumps, compressors, etc.). Pressure switch operating principle Fixed Differential: Detection of a Single Threshold Example: Contact Fixed differential switches Pressure schematics of XMLA –– Adjustable value have a single adjustable PH Fixed --- Non adjustable value setting point (either PH or differential PB PB). The differential between the high and low PH = High point 12 (on rising pressure) points (PH–PB) depends Time PB = Low point on the construction of the (on falling pressure) 1 2 1 2 switch. It is not adjustable. Adjustable Differential: Regulation between Two Thresholds Example: Contact Adjustable differential Pressure schematics of XMLB –– Adjustable value PH switches have setting Adjustable points for both the high spread point (PH) and the low point PH = High point PB (on rising pressure) (PB). Both of these points 12 PB = Low point can be independently (on falling pressure) Time adjusted. 1212 Fixed differential Dual-Stage: Detection of Two Thresholds Dual-stage switches allow two distinct levels of control to be monitored with one device. Each stage PH allows detection of a single threshold with a single setting point (fixed differential). Both these points can be independently adjusted. However, for both stages, the differential between the high point and the low point (PH1–PB1 and PH2–PB2) is fixed and depends on the construction of the switch. Example: Contact schematics of XMLD Pressure –– Adjustable value PH2 Fixed --- Non adjustable value Adjustable Adjustable differential differ- PB2 differential ential PH1 Fixed 2 1 PH PH = High point PB1 differ- (on rising pressure) ential Time PB PB = Low point (on falling pressure) 4 1 2 3 4 12 3 4 3 12 10/2009 © 1998–2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 14 13 14 13 12 11 12 11 24 23 24 23 22 21 22 21 14 13 14 13 14 13 14 13 12 11 12 11 12 11 12 11 14 13 14 13 24 23 24 23 12 11 12 11 22 21 22 21 Introduction Industrial Pressure Switches XML Electromechanical Pressure Switches Vacuum switch operating principle Detection of a single threshold The switches for detection of a single threshold (fixed differential) have a single adjustable setting point (PH). The differential between the high and low points (PH–PB) depends on the inherent characteristics of the switch. It is not adjustable. Example: Contact Time schematics of XMLA –– Adjustable value --- Non adjustable value PH 12 PH = High point Fixed PB = Low point differential PB 1 12 2 Vacuum Regulation between two thresholds The switches for regulation between two thresholds (adjustable differential) have both a high point setting (PH) and a low point setting (PB). Both of these points can be independently adjusted. Example: Contact Time schematics of XMLB –– Adjustable value PH PH = High point Adjustable 12 PB = Low point spread PB 1 12 2 Vacuum Detection of two thresholds The dual-stage switches, for detection at each threshold, have an adjustable high point setting for each stage (PH1 and PH2). Both of these points can be independently adjusted. For both stages, the differential between the high point and the low point (PH1–PB1 and PH2–PB2) depends on the inherent characteristics of the switch. It is not adjustable. Example: Contact schematics of XMLD Time PH1 Fixed –– Adjustable value differ- PB1 Adjustable --- Non adjustable value ential differential 1 2 PH = High point PH2 Fixed PB = Low point PB2 differ- ential 1 2 3 4 1 2 3 4 Vacuum 3 4 Maximum allowable accidental pressure The maximum accidental pressure of XML switches is equal to at least 2.25 times the switch size. If accidental overpressures occur and their duration is less than 50 milliseconds, the pressure damping device incorporated in the XML switches (sizes 10 bar and greater) reduces the effect. 13 © 1998–2009 Schneider Electric 10/2009 All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 14 13 14 13 14 13 14 13 12 11 12 11 12 11 12 11 14 13 14 13 12 11 12 11 24 23 24 23 22 21 22 21 14 13 14 13 12 11 12 11 24 23 24 23 22 21 22 21 Introduction Industrial Pressure Switches XML Electromechanical Pressure Switches Application range of pressure and vacuum switches types XML, XMA and XMX, for control circuits On standard loads: Continuous duty, frequent switching. Insulation voltage limit V 500 (3) 240 200 150 (4) 120 100 60 Inductive loads 48 24 20 (1) 15 (2) 10 8 6 I 5 1 mA 2 mA 3 mA 6 mA 10 mA 1 A 1.5 A 2 A 3 A 6 A 10 A (1) Standard PLC input, type 1 Pressure switches Application range (2) Standard PLC input, type 2 (3) Switching capacity conforming to IEC 947-5-1, XMLA, XMLB, XMLC, XMLD utilisation category AC-15, DC-13 XMX (upcoming product) B300 240 V 1.5 A R300 250 V 0.1 A (4) Switching capacity conforming to IEC 947-5-1, XMLE, XMLF, XMLG utilisation category AC-15, DC-13 B300 120 V 3 A R300 125 V 0.22 A PLC: Programmable Logic Controller On small loads: The use of electromechanical pressure and vacuum switches with programmable logic controllers is becoming more prevalent. On small loads, the switches maintain a failure rate of less than 1 for 100 million operating cycles. Results may vary depending on application. 14 10/2009 © 1998–2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Heating limit (lth) Introduction Industrial Pressure Switches XML Electromechanical Pressure Switches Selecting the switch size After establishing the type of switch required for the application (single threshold detection or regulation between two thresholds), the selection of its size depends on the following criteria: the differential: difference between the high point (PH) and the low point (PB), the maximum pressure allowable per cycle, repeat accuracy, precision and minimum drift. Selecting a fixed differential pressure switch for detecting a single threshold Main criterion: minimum differential Example: for a selected high point (PH) of 7 bar 10 bar 20 bar 35 bar 7 6,5 7 6 7 5 0,6 1 1,5 XMLA010••••• XMLA020••••• XMLA035••••• Differential = 0.5 bar Differential = 1 bar Differential = 2 bar Select an XMLA010••••• (the lowest size) Main criterion: tolerance to overpressures Example: for a selected high point (PH) of 12 bar 45 bar 80 bar 25 45 20 35 12 12 1 1,5 XMLA020••••• XMLA035••••• Allowable accidental overpressure = 45 bar Allowable accidental overpressure = 80 bar Select an XMLA035••••• (the highest size) Main criterion: repeat accuracy, precision and minimum drift Example: for a selected high point (PH) of 18 bar 20 bar 35 bar As a general rule, avoid working at 18 the upper or lower limits of the operating range. 18 1 1,5 XMLA020••••• XMLA035••••• Adjustable from 1–20 bar Adjustable from 1.5–35 bar Select an XMLA035••••• Table 4: Converting Units of Pressure 2 psi kg/cm bar atm mm Hg (Torr) mm H O Pa 2 1 psi = 1 0.07031 0.06895 0.06805 51.71 703.7 6895 2 1 kg/cm = 14.22 1 0.98066 0.96784 735.55 10 000 98 066 5 1 bar = 14.50 1.0197 1 0.98695 750.06 10 197 10 1 atm = 14.70 1.0333 1.0132 1 760.0 10 333 101 325 -3 -3 -3 1 mm Hg = (Torr) 0.01934 1.360 x 10 1.333 x 10 1.316 x 10 1 13.59 133.3 -3 -4 -4 -4 1 mm H O= 1.421 x 10 10 a 10 a 10 0.07361 1 a 9.80 2 -4 -5 -5 -6 -3 1 Pa = 1.45 x 10 1.0197 x 10 10 9.8695 x 10 7.5 x 10 0.10197 1 5 Example: 1 bar = 14.50 psi = 10 Pa 15 © 1998–2009 Schneider Electric 10/2009 All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Introduction Industrial Pressure Switches XML Electromechanical Pressure Switches Table 5: Operating Curves: Fixed Differential, Detecting a Single Threshold Rising pressure Defined by the difference between the Adjustment minimum and maximum high point (PH) range of the + setting values. high point Maxi For a high set point (PH), the lower point (PB) is fixed and cannot be adjusted. For a low set point (PB), the higher point (PH) is fixed and cannot be adjusted. Mini – 0 Low point (PB) Falling pressure 0 range Operating Rising pressure The upper pressure setting at which the pressure or vacuum switch actuates the point on + contacts on rising pressure. rising PH pressure Adjustable throughout the range on rising (PH) pressure. – 0 Falling pressure 0 Rising pressure The pressure at which the switch contact Operating changes state on falling pressure. point on + falling The lower point (PB) is not adjustable PH pressure and is entirely dependent on the high (PB) point setting (PH) and the inherent differential of the switch. PB – 0 Falling pressure 0 PB Differential Rising pressure PH–PB = inherent differential The difference between the operating + point on rising pressure (PH) and the PH operating point on falling pressure (PB). PH – PB This point is not adjustable, so the value of the differential is fixed. PB It is the inherent differential of the switch (contact differential, friction, etc.). – 0 Falling pressure 0 PB Rising pressure Operating point on rising pressure (PH) is Example bar 40 bar (set value at which the contact 60 changes state on rising pressure). The operating point on falling pressure PH 40 (PB) is 28 bar (fixed value at which the contact returns to its original state). 20 Conclusion: the differential is 40 – 28 = 12 bar. 0 bar 0 3 20 28 40 60 PB Falling pressure 16 10/2009 © 1998–2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Adjustment range of high point (PH) Introduction Industrial Pressure Switches XML Electromechanical Pressure Switches Table 6: Operating Curves: Adjustable Differential, Regulating between Two Thresholds Rising pressure Defined by the difference between the Adjustment minimum and maximum high point (PH) range of the + setting values. high point Maxi 1 2 Mini – 0 Low point (PB) Falling 0 range pressure Rising pressure The upper pressure setting at which the Operating pressure or vacuum switch actuates the point on + contacts on rising pressure. rising pressure 1 2 Adjustable throughout the range on rising PH (PH) pressure. – 0 Falling pressure 0 Rising pressure The pressure at which the switch contact Operating changes state on falling pressure. point on + falling The adjustable differential enables the pressure independent setting of the lower point (PB). 1 2 PH (PB) PB" PB' – 0 Falling pressure 0 PB' PB" Low point < High point Differential Rising pressure PH–PB’ = inherent differential + PH–PB” = minimum differential 1 2 PH The difference between the operating point on rising pressure (PH) and the operating PH – PB" PH – PB' point on falling pressure (PB). PB" PB' Note: the low point can be set at any value between PB’ and PB”. – 0 0 Falling pressure PB' PB" Rising pressure Operating point on rising pressure (PH) is Example bar 22 bar (set value at which the contact 30 changes state on rising pressure). The operating point on falling pressure (PB) 1 2 PH 22 ranges from 4 and 19 bar (set value at which 20 the contact returns to its original state). Conclusion: 10 the maximum differential is 22 – 4 = 18 bar, 1 Maximum differential 0 the minimum differential is 0 4 10 19 20 30 bar 2 Minimum differential PB' Falling pressure PB" 22 – 19 = 3 bar. 17 © 1998–2009 Schneider Electric 10/2009 All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Adjustment range of high point (PH) Introduction Industrial Pressure Switches XML Electromechanical Pressure Switches Table 7: Operating Curves: Dual-Stage, Fixed Differential, Detection at Each Threshold (switching on rising pressure) Rising pressure Defined by the difference between the Adjustment minimum and maximum high point ranges of the + setting values of each stage (PH1 and operating points PH2). PH1 and PH2 on 1 2 rising pressure – 0 Rising Adjustment range 0 pressure of high point PH1 Rising pressure The upper pressure setting at which the Operating point pressure or vacuum switch actuates PH2 on rising + contact 2 on rising pressure. pressure 1 2 Adjustable throughout the range on rising PH2 pressure. – 0 0 Rising pressure Rising pressure The upper pressure setting at which the Operating point pressure or vacuum switch actuates PH1 + contact 1 on rising pressure. on rising pressure 1 2 PH2 PH1" PH1' – 0 0 PH1' PH1" Rising pressure Spread Rising pressure PH1 < PH2 PH2–PH1’ = maximum spread + PH2–PH1” = minimum spread The difference between operating points 1 2 PH2 PH2 and PH1 on rising pressure. PH2 – PH1" PH2 – PH1' Note: operating point PH1 can be set at PH1" any value between PH1’ and PH1”. PH1' – 0 0 Rising pressure PH1' PH1" Example: Rising pressure Second stage operating point on rising bar pressure (PH2) = 20 bar (set value at Determining 30 which contact 2 changes state on rising operating points pressure). First stage operating point on rising 1 2 (PH1) can be set between 4.5 and 17 bar PH2 20 pressure for the on rising pressure. two stages Conclusion: 10 the maximum spread is: 20 – 4.5 = 15.5 bar, 1 Maximum spread 0 the minimum spread is: 0 4,5 10 17 20 30 bar 2 Minimum spread PH1' PH1" Rising pressure 20 – 17 = 3 bar. 18 10/2009 © 1998–2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Adjustment range of high point (PH2) Introduction Industrial Pressure Switches XML Electromechanical Pressure Switches Table 8: Operating Curves: Dual-Stage, Fixed Differential, Detection at Each Threshold (switching on rising pressure) Rising pressure Defined by the difference between the Adjustment minimum and maximum high point (PH1 range of + or PH2) setting values for each stage. high point Maxi (PH1 or PH2) For a high set point (PH1 or PH2), the lower point (PB1 or PB2) is fixed and cannot be adjusted. For a low set point (PB1 or PB2), the higher point (PH1 or PH2) is fixed and Mini cannot be adjusted. – 0 Low point (PB) Falling pressure 0 range Rising pressure The upper pressure setting at which the Operating pressure or vacuum switch actuates the point on + contact, for each stage, on rising rising PH pressure. pressure (PH1 or PH2) Adjustable throughout the range on rising pressure. – 0 Falling pressure 0 Rising pressure The pressure at which the switch Operating contact changes state, for each stage, point on + on falling pressure. falling PH pressure The lower point (PB) is not adjustable (PB1 or PB2) and is entirely dependent on the high point setting (PH) and the inherent differential of the switch. PB – 0 Falling pressure 0 PB Rising pressure PH–PB = inherent differential Differential The difference between the operating + point on rising pressure (PH) and the PH operating point on falling pressure (PB), for each stage. This point is not PH – PB adjustable, so the value of the differential is fixed. It is the inherent PB differential of the switch (contact differential, friction, etc.) for each of its two stages. – 0 0 PB Falling pressure Example: Rising pressure For stage 2 (segment GH): bar H stage 1 = 30 Operating point on rising pressure (PH2) F segment EF is 20 bar (set value at which contact 2 stage 2 = changes state on rising pressure). The PH 20 segment GH operating point on falling pressure (PB2) is 14 bar (fixed value at which contact 2 returns to its original state). 10 Conclusion: for stage 2, the differential G 1 Maximum spread is: 20 – 14 = 6 bar. E 0 2 Minimum spread Repeat the same procedure for stage 1 0 bar 3 10 14 20 30 Falling pressure (segment EF). PB 19 © 1998–2009 Schneider Electric 10/2009 All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Adjustment range of high point Introduction Industrial Pressure Switches XML Electromechanical Pressure Switches Interpretation of the Catalog Number for XML Devices Table 9: Interpreting the Catalog Number (Example: XMLA004A2S13) XML A004 A2 S1 3 Designation Catalog Number Nautilus Pressure Switch XML Nonadjustable differential, single pole A Adjustable differential, single pole B Type Adjustable differential, double pole C Nonadjustable differential, double pole D L05 0.05 0.35 L35 0.35 Overpressure 0.30 (4.35) S35 –1 to –0.28 M01 –1 to –0.14 M02 –0.2 to –0.02 M03 –0.5 to 5 M05 1 001 2.5 002 2.5 Overpressure 0.30 (4.35) S02 Operating 4 004 range 4 Overpressure 0.30 (4.35) S04 bar (psi) 10 010 10 Overpressure 0.30 (4.35) S10 20 020 20 Overpressure 0.30 (4.35) S20 35 035 40 040 70 070 160 160 300 300 500 500 Diaphragm type Hydraulic oils, air, fresh, or sea water, 32–158 °F (0–70 °C) A Hydraulic oils, air, fresh, or sea water, 32–320 °F (0–160 °C) B Corrosive fluid C Viscous products P Hydraulic oils or air, 32–140 °F (0–60 °C) R Fresh or sea water, 32–320 °F (0–160 °C) S Input fluid Vacuum type with diaphragm Hydraulic oils, air, fresh or sea water, 32–158 °F (0–70 °C) V Hydraulic oils, air, fresh or sea water, 32–320 °F (0–160 °C) T Piston type Hydraulic oils or air, 32–320 °F (0–160 °C) D Fresh or sea water, 32–320 °F (0–160 °C) E Corrosive fluid, 32–320 °F (0–160 °C) N Not provided 1 Display Provided 2 Threaded hole S Electrical DIN 43650 connector C Connection M12 threaded connector (Micro Change type) D Contact type Dry contact 1 European Pressure G 1/4 (BSP female) 1 Electrical Type 13 (Pg 13.5) Pressure G 1/4 (BSP female) 2 Electrical ISO M20 Entry type U.S.A. Pressure 1/4 in. NPTF 3 Electrical 1/2 in. NPT Japan Pressure PT 1/4 (JIS B0203) 4 Electrical 1/2 in. PF (JIS B0202) Options May indicate factory setting ••• 20 10/2009 © 1998–2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Selection and Specifications Industrial Pressure Switches XML Electromechanical Pressure Switches Table 10: Size: –1 bar (–14.5 psi) Fixed differential, for detection of a single threshold Switches with 1 C/O single-pole contact Pressure connection 1/2" NPT or 1/4" BSP XMLA Vacuum Switches With setting scale Without setting scale Adjustable Range of Operating Point (PB) –0.28 to –1 bar (–4.06 to –14.5 psi) (Falling pressure) Electrical Connection Terminals DIN connector Terminals DIN connector (1) Catalog Numbers Hydraulic oils, fresh water, sea water, air, XMLAM01V2S13 XMLAM01V2C11 XMLAM01V1S13 XMLAM01V1C11 Fluids Controlled up to 158 °F (70 °C) For materials in contact with Hydraulic oils, fresh water, sea water, air, fluid, see pages 77–78 XMLAM01T2S13 XMLAM01T2C11 XMLAM01T1S13 XMLAM01T1C11 corrosive fluids, up to 320 °F (160 °C) Weight, lb (kg) 1.51 (0.685) 1.58 (0.715) 1.51 (0.685) 1.58 (0.715) Supplementary Specifications (not shown under general specifications) At low setting 0.24 bar (3.48 psi), ±0.05 bar (±0.72 psi) Inherent Differential (add to PB to get PH) At high setting 0.24 bar (3.48 psi), ±0.05 bar (±0.72 psi) Per cycle 5 bar (72.5 psi) Maximum Allowable Pressure Accidental 9 bar (130.5 psi) Destruction Pressure 18 bar (261 psi) Cable Entry and Wire Size for Terminal Models 1/2" NPT, 1 x 0.2 mm² minimum, 2 x 2.5 mm² maximum. Connector Type for Connector Models DIN 43650A, 4-pin male. For suitable female connector, see page 73. Vacuum Switch Style Diaphragm (1) For 1 entry tapped for PG 13.5 conduit/cable entry, replace S13 with S11 (example: XMLAM01V2S13 becomes XMLAM01V2S11). Operating Curves Connection Terminal model Rising pressure Time -1 -0.76 -0.6 -0.4 -0.2 -0.04 bar 0 -0.2 -0.28 PH Connector model -0.4 Vacuum switch connector pin view PB -0.6 Vacuum 1 →11 and 13 2 →12 –– Adjustable value -0.8 1 2 3 →4 3 --- Non adjustable value -1 bar Other Versions For switches with alternative tapped cable entries (such as NPT), consult your local sales office. 21 © 1998–2009 Schneider Electric 10/2009 All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Falling pressure 14 13 12 11 Selection and Specifications Industrial Pressure Switches XML Electromechanical Pressure Switches Table 11: Size: –1 bar (–14.5 psi) Adjustable differential, for regulation between two thresholds Switches with 1 C/O single-pole contact Pressure connection 1/2" NPT or 1/4" BSP Vacuum switches type XMLB With setting scale Without setting scale Adjustable Range of Operating Point (PB) –0.14 to –1 bar (–2.03 to –14.5 psi) (Falling pressure) Electrical Connection Terminals DIN connector Terminals DIN connector (1) Catalog Numbers Hydraulic oils, fresh water, sea water, air, XMLBM02V2S13 XMLBM02V2C11 XMLBM02V1S13 XMLBM02V1C11 Fluids Controlled up to 158°F (70°C) For materials in contact with Hydraulic oils, fresh water, sea water, air, fluid, see pages 77–78 XMLBM02T2S13 XMLBM02T2C11 XMLBM02T1S13 XMLBM02T1C11 corrosive fluids, up to 320 °F (160 °C) Weight, lb (kg) 2.24 (1.015) 2.27 (1.030) 2.24 (1.015) 2.27 (1.030) Supplementary Specifications (not shown under general specifications) Min. at low setting 0.13 bar (1.88 psi), ±0.02 bar (±0.29 psi) Possible Differential Min. at high setting 0.13 bar (1.88 psi), ±0.02 bar (±0.29 psi) (add to PB to get PH) Max. at high setting 0.8 bar (11.6 psi) Per cycle 5 bar (72.5 psi) Maximum Allowable Pressure Accidental 9 bar (130.5 psi) Destruction Pressure 18 bar (261 psi) Cable Entry and Wire Size for Terminal Models 1/2" NPT, 1 x 0.2 mm² minimum, 2 x 2.5 mm² maximum. Connector Type for Connector Models DIN 43650A, 4-pin male. For suitable female connector, see page 73. Vacuum Switch Style Diaphragm (1) For 1 entry tapped for PG 13.5 conduit/cable entry, replace S13 with S11 (example: XMLBM02V2S13 becomes XMLBM02V2S11). Operating Curves Connection 1 Maximum Terminal model Time Rising pressure differential -1 -0.87 -0.6 -0.4 -0.2 -0.01 bar 0 2 Minimum differential -0.14 –– Adjustable -0.2 PH value Connector model Vacuum switch connector pin view -0.4 1 →11 and 13 2 PB -0.6 2 →12 Vacuum 1 2 3 →4 3 1 -0.8 -1 bar Other Versions For switches with alternative tapped cable entries (such as NPT), consult your local sales office. 22 10/2009 © 1998–2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Falling pressure 14 13 12 11 Selection and Specifications Industrial Pressure Switches XML Electromechanical Pressure Switches Table 12: Size: –1 bar (–14.5 psi) Adjustable differential, for regulation between two thresholds Switches with 2 C/O single-pole contacts Pressure connection 1/2" NPT or 1/4" BSP Vacuum switches type XMLC With setting scale Adjustable Range of Operating Point (PB) –0.14 to –1 bar (–2.03 to –14.5 psi) (Falling pressure) Electrical Connection Terminals (1) Catalog Numbers Hydraulic oils, fresh water, sea water, XMLCM02V2S13 air, up to 158 °F (70 °C) Fluids Controlled For materials in contact with Hydraulic oils, fresh water, sea water, fluid, see pages 77–78 air, corrosive fluids, up to 320 °F XMLCM02T2S13 (160 °C) Weight, lb (kg) 2.24 (1.015) Supplementary Specifications (not shown under general specifications) Min. at low setting 0.13 bar (1.89 psi), ±0.02 bar (±0.29 psi). Possible Differential Min. at high setting 0.14 bar (2.03 psi), ±0.02 bar (±0.29 psi). (add to PB to get PH) Max. at high setting 0.8 bar (11.6 psi) Per cycle 5 bar (72.5 psi) Maximum Allowable Pressure Accidental 9 bar (130.5 psi) Destruction Pressure 18 bar (261 psi) Cable Entry and Wire Size for Terminal Models 1/2" NPT, 1 x 0.2 mm² minimum, 2 x 2.5 mm² maximum. Vacuum Switch Style Diaphragm (1) For 1 entry tapped for PG 13.5 conduit/cable entry, replace S13 with S11 (example: XMLCM02V2S13 becomes XMLCM02V2S11). Operating Curves Connection 1 Maximum Terminal model Time Rising pressure -0.86 -0.6 -0.4 -0.14 0 differential bar -0.01 2 Minimum differential -0.2 –– Adjustable value PH -0.4 2 PB -0.6 Vacuum -0.8 1 bar Other Versions For switches with alternative tapped cable entries (such as NPT), consult your local sales office. 23 © 1998–2009 Schneider Electric 10/2009 All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Falling pressure 14 13 12 11 24 23 22 21 Selection and Specifications Industrial Pressure Switches XML Electromechanical Pressure Switches Table 13: Size: –1 bar (–14.5 psi) Dual-stage, fixed differential, for detection at each threshold Switches with 2 C/O single-pole contacts (one per stage) Pressure connection 1/2" NPT or 1/4" BSP Vacuum switches type XMLD Without setting scale 2nd stage operating point (PB2) –0.12 to –1 bar (–1.74 to –14.5 psi) Adjustable Range of Operating Points (Falling pressure) 1st stage operating point (PB1) –0.10 to –0.98 bar (–1.45 to –14.21 psi) Spread between the Two Stages (PB2—PB1) 0.02 to 0.88 bar (0.29 to 12.76 psi) Electrical Connection Terminals (1) Catalog Numbers Hydraulic oils, fresh water, sea water, air, XMLDM02V1S13 Fluids Controlled up to 158°F (70°C) For materials in contact with fluid, see Hydraulic oils, fresh water, sea water, air, pages 77–78 XMLDM02T1S13 corrosive fluids, up to 320 °F (160 °C) Weight, lb (kg) 2.24 (1.015) Supplementary Specifications (not shown under general specifications) At low setting 0.1 bar (1.45 psi), ±0.035 bar (±0.51 psi) Inherent Differential (add to PB1/PB2 to get PH1/PH2) At high setting 0.1 bar (1.45 psi), ±0.02 bar (±0.29 psi) Per cycle 5 bar (72.5 psi) Maximum Allowable Pressure Accidental 9 bar (130.5 psi) Destruction Pressure 18 bar (261 psi) Cable Entry and Wire Size for Terminal Models 1/2" NPT, 1 x 0.2 mm² minimum, 2 x 2.5 mm² maximum. Vacuum Switch Style Diaphragm (1) For 1 entry tapped for PG 13.5 conduit/cable entry, replace S13 with S11 (example: XMLDM02V1S13 becomes XMLDM02V1S11). Operating Curves High setting trip points of contacts 1 and 2 Inherent Differential of contacts 1 and 2 PH1 setting (falling pressure) Rising pressure Time -0.98 -0.8 -0.6 -0.4 -0.12 0 -1 -0.88 -0.6 -0.4 -0.2 -0.02 0 0 E -0.12 -0.12 G PH1 1 Maximum differential -0.2 -0.2 PB1 2 Minimum differential -0.4 -0.4 PH2 PB2 2 -0.6 Vacuum -0.6 EF Contact 1 (stage 1) GH Contact 2 (stage 2) 1 -0.8 -0.8 –– Adjustable value --- Non adjustable value F -0.98 -0.98 bar H bar Connection: Terminal model Contact 1 (stage 1) Contact 2 (stage 2) Other Versions For switches with alternative tapped cable entries (such as NPT), consult your local sales office. 24 10/2009 © 1998–2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com bar 14 13 12 11 PH2 setting (falling pressure) 24 23 22 21 bar Falling pressure Selection and Specifications Industrial Pressure Switches XML Electromechanical Pressure Switches Table 14: Size: –200 mbar (–2.9 psi) Adjustable differential, for regulation between two thresholds Switches with 1 C/O single-pole contact Pressure connection 1/2" NPT or 1/4" BSP Vacuum switches type XMLB With setting scale Adjustable Range of Operating Point (PB) –20 to –200 mbar (–0.29 to –2.9 psi) (Falling pressure) Electrical Connection Terminals (1) Catalog Numbers Hydraulic oils, air, up to 320 °F XMLBM03R2S13 Fluids Controlled (160 °C) For materials in contact with Fresh water, sea water, corrosive fluid, see pages 77–78 XMLBM03S2S13 fluids, up to 320 °F (160 °C) Weight, lb (kg) 7.30 (3.310) Supplementary Specifications (not shown under general specifications) Min. at low setting 18 mbar (0.26 psi), ±2 mbar (±0.29 psi) Possible Differential Min. at high setting 18 mbar (0.26 psi), ±2 mbar (±0.29 psi) (add to PB to get PH) Max. at high setting 180 mbar (2.6 psi) Per cycle 1 bar (14.5 psi) Maximum Allowable Pressure Accidental 2 bar (29 psi) Destruction Pressure 3.5 bar (50.75 psi) Cable Entry and Wire Size for Terminal Models 1/2" NPT, 1 x 0.2 mm² minimum, 2 x 2.5 mm² maximum. Vacuum Switch Style Diaphragm (1) For 1 entry tapped for PG 13.5 conduit/cable entry, replace S13 with S11 (example: XMLBM03R2S13 becomes XMLBM03R2S11). Operating Curves Connection Terminal model 1 Maximum Time Rising pressure differential -182 -160 -120 -80 -40 -20 -2 mbar 0 2 Minimum -20 differential -40 PH -80 2 PB -120 Vacuum –– Adjustable value -160 1 -200 mbar Other Versions For switches with alternative tapped cable entries (such as NPT), consult your local sales office. 25 © 1998–2009 Schneider Electric 10/2009 All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Falling pressure 14 13 12 11 Selection and Specifications Industrial Pressure Switches XML Electromechanical Pressure Switches Table 15: Size 50 mbar (0.72 psi) Adjustable differential, for regulation between two thresholds Switches with 1 C/O single-pole contact Pressure connection 1/2" NPT or 1/4" BSP Pressure Switches, Type XMLB With setting scale Without setting scale p Adjustable Range of Operating Point (PH) 2.6–50 mbar (0.038–0.72 psi) (Rising pressure) Electrical Connection Terminals (1) Catalog Numbers Hydraulic oils, air, up to 320 °F XMLBL05R2S13 XMLBL05R1S13 (160 °C) Fluids Controlled For materials in contact with Fresh water, sea water, fluid, see pages 77–78 corrosive fluids, up to 320 °F XMLBL05S2S13 XMLBL05S1S13 (160 °C) Weight, lb (kg) 5.34 (2.420) Supplementary Specifications (not shown under general specifications) Min. at low setting 1.4 mbar (0.02 psi), –0.8 mbar, +1.1 mbar (–0.01 psi, +0.02 psi). Possible Differential (subtract from PH to get Min. at high setting 4 mbar (0.06 psi), ±1.4 mbar, (±0.02 psi) PB) Max. at high setting 40 mbar (0.58 psi) Maximum Allowable Per cycle 62.5 mbar (0.90 psi) Pressure Accidental 112.5 mbar (1.63 psi) Destruction Pressure 225 mbar (3.26 psi) Cable Entry and Wire Size for Terminal Models 1/2" NPT, 1 x 0.2 mm² minimum, 2 x 2.5 mm² maximum. Pressure Switch Style Diaphragm (1) For 1 entry tapped for PG 13.5 conduit/cable entry, replace S13 with S11 (example: XMLBL05R2S13 becomes XMLBL05R2S11). Operating Curves Connection: Terminal model 1 Maximum mbar Pressure 50 differential PH 2 Minimum 1 differential 40 PB 30 2 20 Time 10 –– Adjustable value 2,6 0 1,2 10 20 304 406 mbar Falling pressure Other Versions For switches with DIN 43650A connector or alternative tapped cable entries (such as NPT), consult your local sales office. 26 10/2009 © 1998–2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Rising pressure 14 13 12 11 Selection and Specifications Industrial Pressure Switches XML Electromechanical Pressure Switches Table 16: Size 5 bar (72.5 psi) Adjustable differential, for regulation between two thresholds Switches with 1 C/O single-pole contact Pressure connection 1/2" NPT or 1/4" BSP Vacu-Pressure Switches, Type XMLB With setting scale Without setting scale Adjustable Range of Operating Point (PH) –0.5 to 5 bar (–7.25 to 72.5 psi) (Rising pressure) Electrical Connection Terminals DIN connector Terminals DIN connector (1) Catalog Numbers Hydraulic oils, fresh water, sea water, XMLBM05A2S13 XMLBM05A2C11 XMLBM05A1S13 XMLBM05A1C11 air, up to 158 °F (70 °C) Hydraulic oils, fresh water, sea water, Fluids Controlled XMLBM05B2S13 XMLBM05B2C11 XMLBM05B1S13 XMLBM05B1C11 air, up to 320 °F (160 °C) For materials in contact with fluid, see pages 77–78 Corrosive fluids, up to 320 °F (160 °C) XMLBM05C2S13 XMLBM05C2C11 XMLBM05C1S13 XMLBM05C1C11 Viscous products, up to 320 °F XMLBM05P2S13 XMLBM05P2C11 XMLBM05P1S13 XMLBM05P1C11 (160 °C) (G1¼” pressure connection) Weight, lb (kg) 1.51 (0.685) 1.58 (0.715) 1.55 (0.705) 1.62 (0.735) Supplementary Specifications (not shown under general specifications) Min. at low setting 0.5 bar (7.25 psi), ±0.05 bar (±0.72 psi) Possible Differential Min. at high setting 0.5 bar (7.25 psi), ±0.05 bar (±0.72 psi) (subtract from PH to get PB) Max. at high setting 6 bar (87 psi) Per cycle 6.25 bar (90.62 psi) Maximum Allowable Pressure Accidental 11.25 bar (163.12 psi) Destruction Pressure 23 bar (333.5 psi) Cable Entry and Wire Size for Terminal Models 1/2" NPT, 1 x 0.2 mm² minimum, 2 x 2.5 mm² maximum. Connector Type for Connector Models DIN 43650A, 4-pin male. For suitable female connector, see page 73. Vacu-Pressure Switch Style Diaphragm (1) For 1 entry tapped for PG 13.5 conduit/cable entry, replace S13 with S11 (example: XMLBM05A2S13 becomes XMLBM05A2S11). Operating Curves Connection 1 Maximum differential Terminal model bar Pressure 2 Minimum differential 5 PH1 4 PB1 1 3 Connector model PH2 1 2 Vacu-pressure switch pin view 0 2 Time PB2 2 1 →11 and 13 1 0,5 2 →12 3 1 2 PH3 0 3 3 →14 -0,5 PB3 -1 -1 0 12 3 4 4,5 4,5 5 bar Vacuum –– Adjustable value Falling pressure Other Versions For switches with alternative tapped cable entries (such as NPT), consult your local sales office. 27 © 1998–2009 Schneider Electric 10/2009 All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Rising pressure 14 13 12 11 Selection and Specifications Industrial Pressure Switches XML Electromechanical Pressure Switches Table 17: Size 5 bar (72.5 psi) Adjustable differential, for regulation between two thresholds Switches with 2 C/O single-pole contacts Pressure connection 1/2" NPT or 1/4" BSP Vacu-pressure Switches, Type XMLC With setting scale Adjustable Range of Operating Point (PH) –0.55 to 5 bar (–7.97 to 72.5 psi) (Rising pressure) Terminals Electrical Connection (1) Catalog Numbers Hydraulic oils, fresh water, sea XMLCM05A2S13 water, air, up to 158 °F (70 °C) Fluids Controlled Hydraulic oils, fresh water, sea XMLCM05B2S13 For materials in contact with water, air, up to 320 °F (160 °C) fluid, see pages 77–78 Corrosive fluids, up to 320 °F XMLCM05C2S13 (160 °C) 1.51 (0.685) Weight, lb (kg) Supplementary Specifications (not shown under general specifications) Min. at low setting 0.45 bar (6.52 psi), ±0.1 bar (±1.45 psi) Possible Differential Min. at high setting 0.45 bar (6.52 psi), ±0.1 bar (±1.45 psi) (subtract from PH to get PB) Max. at high setting 6 bar (87 psi) Per cycle 6.25 bar (90.62 psi) Maximum Allowable Pressure Accidental 11.25 bar (163.12 psi) 23 bar (333.5 psi) Destruction Pressure 1/2" NPT, 1 x 0.2 mm² minimum, 2 x 2.5 mm² maximum. Cable Entry and Wire Size for Terminal Models Diaphragm Vacu-Pressure Switch Style (1) For 1 entry tapped for PG 13.5 conduit/cable entry, replace S13 with S11 (example: XMLCM05A2S13 becomes XMLCM05A2S11). Operating Curves Connection 1 Maximum Terminal model bar Pressure differential 5 PH1 2 Minimum differential 4 PB1 1 3 Connector model PH2 1 2 Vacu-pressure switch pin view 0 2 Time PB2 2 1 →11 and 13 1 0.5 2 →12 3 1 2 PH3 0 3 3 →14 -0.55 –– Adjustable PB3 -1 value -1 12 3 45 4.55 bar 0 Vacuum Falling pressure For switches with alternative tapped cable entries (such as NPT), consult your local sales office. Other Versions 28 10/2009 © 1998–2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Rising pressure 14 13 12 11 24 23 22 21 Selection and Specifications Industrial Pressure Switches XML Electromechanical Pressure Switches Table 18: Size 350 mbar (5.07 psi) Adjustable differential, for regulation between two thresholds Switches with 1 C/O single-pole contact Pressure connection 1/2" NPT or 1/4" BSP Pressure Switches, Type XMLB With setting scale With setting scale 30 bar (435 psi) overpressure Adjustable Range of Operating Point (PH) 45–350 mbar (0.65–5.07 psi) 42–330 mbar (0.61–4.78 psi) (Rising pressure) Electrical Connection Terminals DIN connector Terminals (1) Catalog Numbers Hydraulic oils, air, up to 320 °F XMLBL35R2S13 XMLBL35R2C11 XMLBS35R2S13 (160 °C) Fluids Controlled Fresh water, sea water, corrosive fluids, up to 320 °F XMLBL35S2S13 XMLBL35S2C11 — For materials in contact (160 °C) with fluid, see pages 77– 78 Viscous products, up to 320 °F (160 °C) (G1¼” pressure XMLBL35P2S13 XMLBL35P2C11 — connection) Weight, lb (kg) 5.68 (2.575) 5.71 (2.590) 7.72 (3.500) Supplementary Specifications (not shown under general specifications) 33 mbar (0.48 psi), –8 mbar, +3 mbar Min. at low setting 42 mbar (0.60 psi), –8 mbar, +3 mbar (–0.12 psi, +0.04 psi) Possible Differential (–0.12 psi, +0.04 psi) (subtract from PH Min. at high setting 50 mbar (0.72 psi), ±8 mbar (±0.11 psi) 58 mbar (0.84 psi), ±8 mbar (±0.11 psi) to get PB) Max. at high setting 300 mbar (4.35 psi) 250 mbar (3.62 psi) Per cycle 1.25 bar (18.12 psi) 30 bar (435 psi) Maximum Allowable Pressure Accidental 2.25 bar (32.62 psi) 37.5 bar (543.75 psi) Destruction Pressure 4.5 bar (65.25 psi) 67.5 bar (978.75 psi) Cable Entry and Wire Size for Terminal Models 1/2" NPT, 1 x 0.2 mm² minimum, 2 x 2.5 mm² maximum. Connector Type for Connector Models DIN 43650A, 4-pin male. For suitable female connector, see page 73. Pressure Switch Style Diaphragm (1) For 1 entry tapped for PG 13.5 conduit/cable entry, replace S13 with S11 (example: XMLBL35R2S13 becomes XMLBL35R2S11). Operating Curves Connection Terminal model mbar Pressure 350 PH 300 1 PB 200 2 Connector model Pressure switch connector pin view 1 →11 and 13 100 Time –– Adjustable value 2 →12 1 2 45 3 3 →14 1 Maximum differential 0 3 50 100 200 300 mbar 2 Minimum differential Falling pressure Other Versions For switches with alternative tapped cable entries (such as NPT), consult your local sales office. 29 © 1998–2009 Schneider Electric 10/2009 All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Rising pressure 14 13 12 11 Selection and Specifications Industrial Pressure Switches XML Electromechanical Pressure Switches Table 19: Size 350 mbar (5.07 psi) Adjustable differential, for regulation between two thresholds Switches with 1 C/O single-pole contact Pressure connection 1/2" NPT or 1/4" BSP Pressure Switches, Type XMLB Without setting scale Adjustable Range of Operating Point (PH) 45–350 mbar (0.65–5.07 psi) (Rising pressure) Electrical Connection Terminals DIN connector (1) Catalog Numbers Hydraulic oils, air, up to 320 °F XMLBL35R1S13 XMLBL35R1C11 (160 °C) Fluids Controlled Fresh water, sea water, corrosive XMLBL35S1S13 XMLBL35S1C11 fluids, up to 320 °F (160 °C) For materials in contact with fluid, see pages 77–78 Viscous products, up to 320 °F (160 °C) (G1¼” pressure XMLBL35P1S13 XMLBL35P1C11 connection) Weight, lb (kg) 5.68 (2.575) 5.71 (2.590) Supplementary Specifications (not shown under general specifications) Min. at low setting 42 mbar (0.60 psi), –8 mbar, +3 mbar (–0.12 psi, +0.04 psi) Possible Differential Min. at high setting 50 mbar (0.72 psi), ±8 mbar (±0.11 psi) (subtract from PH to get PB) Max. at high setting 300 mbar (4.35 psi) Maximum Allowable Per cycle 1.25 bar (18.12 psi) Pressure Accidental 2.25 bar (32.62 psi) Destruction Pressure 4.5 bar (65.25 psi) Cable Entry and Wire Size for Terminal Models 1/2" NPT, 1 x 0.2 mm² minimum, 2 x 2.5 mm² maximum. Connector Type for Connector Models DIN 43650A, 4-pin male. For suitable female connector, see page 73. Pressure Switch Style Diaphragm (1) For 1 entry tapped for PG 13.5 conduit/cable entry, replace S13 with S11 (example: XMLBL35R1S13 becomes XMLBL35R1S11). Operating Curves Connection 1 Maximum Terminal model mbar Pressure 350 differential PH 2 Minimum 300 differential 1 PB 200 2 Connector model Pressure switch connector pin view 100 Time 1 →11 and 13 –– Adjustable value 1 2 45 2 →12 3 3 →14 0 3 50 100 200 300 mbar Falling pressure Other Versions For switches with alternative tapped cable entries (such as NPT), consult your local sales office. 30 10/2009 © 1998–2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Rising pressure 14 13 12 11 Selection and Specifications Industrial Pressure Switches XML Electromechanical Pressure Switches Table 20: Size 350 mbar (5.07 psi) Adjustable differential, for regulation between two thresholds Switches with 2 C/O single-pole contacts Pressure connection 1/2" NPT or 1/4" BSP Pressure Switches, Type XMLC With setting scale With setting scale 30 bar (435 psi) overpressure Adjustable Range of Operating Point (PH) 45–350 mbar (0.65–5.07 psi) 42–330 mbar (0.61–4.78 psi) (Rising pressure) Terminals Electrical Connection (1) Catalog Numbers Hydraulic oils, air, up to 320 °F XMLCL35R2S13 XMLCS35R2S13 (160 °C) Fluids Controlled For materials in contact with Fresh water, sea water, fluid, see pages 77–78 corrosive fluids, up to 320 °F XMLCL35S2S13 — (160 °C) 5.68 (2.575) 7.72 (3.500) Weight, lb (kg) Supplementary Specifications (not shown under general specifications) Min. at low setting 20 mbar (0.29 psi), ±20 mbar (±0.29 psi) 40 mbar (0.58 psi), ±20 mbar (±0.29 psi) Possible Differential Min. at high setting 35 mbar (0.51 psi), ±20 mbar (±0.29 psi) 88 mbar (1.27 psi), ±20 mbar (±0.29 psi) (subtract from PH to get PB) Max. at high setting 300 mbar (4.35 psi) 230 mbar (3.33 psi) Per cycle 1.25 bar (18.12 psi) 30 bar (435 psi) Maximum Allowable Pressure Accidental 2.25 bar (32.62 psi) 37.5 bar (543.75 psi) 4.5 bar (65.25 psi) 67.5 bar (978.75 psi) Destruction Pressure 1/2" NPT, 1 x 0.2 mm² minimum, 2 x 2.5 mm² maximum. Cable Entry and Wire Size for Terminal Models Diaphragm Pressure Switch Style (1) For 1 entry tapped for PG 13.5 conduit/cable entry, replace S13 with S11 (example: XMLCL35R2S13 becomes XMLCL35R2S11). Operating Curves Connection 1 Maximum mbar Pressure Terminal model 350 differential PH 1 2 Minimum 300 differential PB 200 2 100 Time –– Adjustable value 45 0 02550 100 200 315 mbar Falling pressure Other Versions For switches with alternative tapped cable entries (such as NPT), consult your local sales office. 31 © 1998–2009 Schneider Electric 10/2009 All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Rising pressure 14 13 12 11 24 23 22 21 Selection and Specifications Industrial Pressure Switches XML Electromechanical Pressure Switches Table 21: Size 350 mbar (5.07 psi) Dual-stage, fixed differential, for detection at each threshold Switches with 2 C/O single-pole contacts (one per stage) Pressure connection 1/2" NPT or 1/4" BSP Pressure Switches, Type XMLD Without setting scale Adjustable Range of 2nd stage operating point (PH2) 58–350 mbar (0.84–5.07 psi) Each Operating Point 1st stage operating point (PH1) 33–325 mbar (0.48–4.71 psi) (Rising pressure) Spread between the Two Stages (PH2–PH1) 25–310 mbar (0.36–4.50 psi) Electrical Connection Terminals (1) Catalog Numbers Hydraulic oils, air, up to 320 °F XMLDL35R1S13 Fluids Controlled (160 °C) For materials in contact with Fresh water, sea water, corrosive fluid, see pages 77–78 XMLDL35S1S13 fluids, up to 320 °F (160 °C) Weight, lb (kg) 5.68 (2.575) Supplementary Specifications (not shown under general specifications) Inherent Differential At low setting 30 mbar (0.44 psi), ±10 mbar (±0.15 psi) (subtract from PH1/PH2 At high setting 30 mbar (0.44 psi), ±8 mbar (±0.11 psi) to get PB1/PB2) Per cycle 1.25 bar (18.12 psi) Maximum Allowable Pressure Accidental 2.25 bar (32.62 psi) Destruction Pressure 4.5 bar (65.25 psi) Cable Entry and Wire Size for Terminal Models 1/2" NPT, 1 x 0.2 mm² minimum, 2 x 2.5 mm² maximum. Pressure Switch Style Diaphragm (1) For 1 entry tapped for PG 13.5 conduit/cable entry, replace S13 with S11 (example: XMLDL35R1S13 becomes XMLDL35R1S11). Operating Curves High setting trip points of contacts 1 and 2 Inherent differential of contacts 1 and 2 Pressure mbar mbar 350 350 H PH2 343 F 325 1 300 PB2 300 PH1 PB1 200 200 2 100 Time 100 G –– Adjustable value 58 58 33 E --- Non adjustable value 0 0 Connection 3 28 100 200 295 320mbar 0 33 100 200 300 325mbar Rising pressure PH1 setting (falling pressure) Terminal model 1 Maximum differential EF Contact 1 (stage 1) Contact 1 (stage 1) Contact 2 (stage 2) 2 Minimum differential GH Contact 2 (stage 2) For switches with alternative tapped cable entries (such as NPT), Other Versions consult your local sales office. 32 10/2009 © 1998–2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com PH2 setting (falling pressure) Falling pressure 14 13 12 11 24 23 22 21 Selection and Specifications Industrial Pressure Switches XML Electromechanical Pressure Switches Table 22: Size 1 bar (14.5 psi) Fixed differential, for detection of a single threshold Switches with 1 C/O single-pole contact Pressure connection 1/2" NPT or 1/4" BSP Pressure Switches, Type XMLA With setting scale Without setting scale Adjustable Range of Operating Point (PH) 0.03–1 bar (0.435–14.5 psi) (Rising pressure) Electrical Connection Terminals DIN connector Terminals DIN connector (1) Catalog Numbers Hydraulic oils, air, up to 320 °F XMLA001R2S13 XMLA001R2C11 XMLA001R1S13 XMLA001R1C11 (160 °C) Fluids Controlled For materials in contact with Fresh water, sea water, fluid, see pages 77–78 corrosive fluids, up to 320 °F XMLA001S2S13 XMLA001S2C11 XMLA001S1S13 XMLA001S1C11 (160 °C) Weight, lb (kg) 5.63 (2.555) 5.67 (2.570) 5.63 (2.555) 5.67 (2.570) Supplementary Specifications (not shown under general specifications) At low setting 0.02 bar (0.29 psi), ±0.01 bar (±0.14 psi) Inherent Differential (subtract from PH to get PB) At high setting 0.04 bar (0.58 psi), ±0.01 bar (±0.14 psi) Per cycle 1.25 bar (18.12 psi) Maximum Allowable Pressure Accidental 2.25 bar (32.62 psi) Destruction Pressure 4.5 bar (65.25 psi) Cable Entry and Wire Size for Terminal Models 1/2" NPT, 1 x 0.2 mm² minimum, 2 x 2.5 mm² maximum. Connector Type for Connector Models DIN 43650A, 4-pin male. For suitable female connector, see page 73. Pressure Switch Style Diaphragm (1) For 1 entry tapped for PG 13.5 conduit/cable entry, replace S13 with S11 (example: XMLA001R2S13 becomes XMLA001R2S11). Operating Curves Connection Terminal model Pressure bar 1 PH 0,8 PB Connector model 0,6 Pressure switch connector pin view 0,4 1 →11 and 13 Time 2 →12 1 2 –– Adjustable value 0,2 3 3 →14 --- Non adjustable value 0,03 0 0,01 0,2 0,4 0,6 0,8 0,96 bar Falling pressure Other Versions For switches with alternative tapped cable entries (such as NPT), consult your local sales office. 33 © 1998–2009 Schneider Electric 10/2009 All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Rising pressure 14 13 12 11 Selection and Specifications Industrial Pressure Switches XML Electromechanical Pressure Switches Table 23: Size 1 bar (14.5 psi) Adjustable differential, for regulation between two thresholds Switches with 1 C/O single-pole contact Pressure connection 1/2" NPT or 1/4" BSP Pressure Switches, Type XMLB With setting scale Without setting scale Adjustable Range of Operating Point (PH) 0.05–1 bar (0.72–14.5 psi) (Rising pressure) Electrical Connection Terminals DIN connector Terminals DIN connector (1) Catalog Numbers Hydraulic oils, air, up to 320 °F XMLB001R2S13 XMLB001R2C11 XMLB001R1S13 XMLB001R1C11 (160 °C) Fresh water, sea water, corrosive Fluids Controlled XMLB001S2S13 XMLB001S2C11 XMLB001S1S13 XMLB001S1C11 fluids, up to 320 °F (160 °C) (2) Viscous products, up to 320 °F (160 °C) XMLB001P2S13 XMLB001P2C11 XMLB001P1S13 XMLB001P1C11 (G1¼” pressure connection) Weight, lb (kg) 5.68 (2.575) 5.71 (2.590) 5.68 (2.575) 5.71 (2.590) Supplementary Specifications (not shown under general specifications) Min. at low setting 0.04 bar (0.58 psi), ±10 mbar (±0.14 psi) Possible Differential Min. at high setting 0.06 bar (0.87 psi), ±20 mbar (±0.29 psi) (subtract from PH to get PB) Max. at high setting 0.75 bar (10.87 psi) Per cycle 1.25 bar (18.12 psi) Maximum Allowable Pressure Accidental 2.25 bar (32.62 psi) Destruction Pressure 4.5 bar (65.25 psi) Cable Entry and Wire Size for Terminal Models 1/2" NPT, 1 x 0.2 mm² minimum, 2 x 2.5 mm² maximum. Connector Type for Connector Models DIN 43650A, 4-pin male. For suitable female connector, see page 73. Pressure Switch Style Diaphragm (1) For 1 entry tapped for PG 13.5 conduit/cable entry, replace S13 with S11 (example: XMLB001R2S13 becomes XMLB001R2S11). (2) Component materials of units in contact with the fluid, see pages 77–78. Operating Curves Connection 1 Maximum Terminal model bar Pressure differential 1 2 Minimum PH differential 0.8 1 PB Connector model 0.6 Pressure switch connector pin view 2 0.4 –– Adjustable 1 →11 and 13 value Time 2 →12 1 2 0.2 3 3 →14 0.05 0 0.01 0.25 0.4 0.6 0.8 0.94 bar Falling pressure Other Versions For switches with alternative tapped cable entries (such as NPT), consult your local sales office. 34 10/2009 © 1998–2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Rising pressure 14 13 12 11 Selection and Specifications Industrial Pressure Switches XML Electromechanical Pressure Switches Table 24: Size 1 bar (14.5 psi) Adjustable differential, for regulation between two thresholds Switches with 2 C/O single-pole contacts Pressure connection 1/2" NPT or 1/4" BSP Pressure Switches, Type XMLC With setting scale Adjustable Range of Operating Point (PH) 0.05–1 bar (0.725–14.5 psi) (Rising pressure) Electrical Connection Terminals (1) Catalog Numbers Hydraulic oils, air, up to 320 °F XMLC001R2S13 (160 °C) Fluids Controlled Fresh water, sea water, (2) corrosive fluids, up to 320 °F XMLC001S2S13 (160 °C) Weight, lb (kg) 5.63 (2.555) Supplementary Specifications (not shown under general specifications) Min. at low setting 0.03 bar (0.43 psi), ±0.01 bar (±0.14 psi) Possible Differential Min. at high setting 0.04 bar (0.58 psi), ±0.03 bar (±0.43 psi) (subtract from PH to get PB) Max. at high setting 0.8 bar (11.6 psi) Per cycle 1.25 bar (18.12 psi) Maximum Allowable Pressure Accidental 2.25 bar (32.62 psi) Destruction Pressure 4.5 bar (65.25 psi) Cable Entry and Wire Size for Terminal Models 1/2" NPT, 1 x 0.2 mm² minimum, 2 x 2.5 mm² maximum. Pressure Switch Style Diaphragm (1) For 1 entry tapped for PG 13.5 conduit/cable entry, replace S13 with S11 (example: XMLC001R2S13 becomes XMLC001R2S11). (2) Component materials of units in contact with the fluid, see pages 77–78. Operating Curves Connection 1 Maximum Terminal model Pressure bar 1 differential PH 2 Minimum differential 1 PB 0.6 2 0.4 –– Adjustable value Time 0.2 0.05 0 0.02 0.2 0.4 0.6 0.8 0.96 bar Falling pressure Other Versions For switches with alternative tapped cable entries (such as NPT), consult your local sales office. 35 © 1998–2009 Schneider Electric 10/2009 All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Rising pressure 14 13 12 11 24 23 22 21 Selection and Specifications Industrial Pressure Switches XML Electromechanical Pressure Switches Table 25: Size 1 bar (14.5 psi) Dual-stage, fixed differential, for detection at each threshold Switches with 2 C/O single-pole contacts (one per stage) Pressure connection 1/2" NPT or 1/4" BSP Pressure Switches, Type XMLD Without setting scale Adjustable Range of 2nd stage operating point (PH2) 0.12–1 bar (1.74–14.5 psi) Each Operating Point 1st stage operating point (PH1) 0.04–0.92 bar (0.58–13.34 psi) (Rising pressure) Spread between the Two Stages (PH2–PH1) 0.08–0.73 bar (1.16–10.59 psi) Electrical Connection Terminals (1) Catalog Numbers Hydraulic oils, air, up to 320 °F XMLD001R1S13 (160 °C) Fluids Controlled Fresh water, sea water, (2) corrosive fluids, up to 320 °F XMLD001S1S13 (160 °C) Weight, lb (kg) 5.68 (2.575) Supplementary Specifications (not shown under general specifications) Inherent Differential At low setting 0.03 bar (0.44 psi), ±0.01 bar (±0.14 psi) (subtract from PH1/PH2 At high setting 0.07 bar (1.02 psi), ±0.04 bar (±0.58 psi) to get PB1/PB2) Per cycle 1.25 bar (18.12 psi) Maximum Allowable Pressure Accidental 2.25 bar (32.62 psi) Destruction Pressure 4.5 bar (65.25 psi) Cable Entry and Wire Size for Terminal Models 1/2" NPT, 1 x 0.2 mm² minimum, 2 x 2.5 mm² maximum. Pressure Switch Style Diaphragm (1) For 1 entry tapped for PG 13.5 conduit/cable entry, replace S13 with S11 (example: XMLD001R1S13 becomes XMLD001R1S11). (2) Component materials of units in contact with the fluid, see pages 77–78. Operating Curves High setting trip points of contacts 1 and 2 Inherent differential of contacts 1 and 2 bar Pressure bar 1 1 H PH2 0.92 PB2 1 F 0.8 0.77 PH1 PB1 0.6 0.6 2 0.4 0.4 Time 0.2 –– Adjustable value 0.2 G --- Non adjustable value 0.12 0.12 0.04 Connection: Terminal model E 0 0 0.04 0.27 0.4 0.6 0.8 0.92 bar 0.01 0.09 0.2 0.4 0.6 0.85 0.93 bar Contact 2 (stage 2) Contact 1 (stage 1) PH1 setting (rising pressure) Falling pressure 1 Maximum differential EF Contact 1 (stage 1) 2 Minimum differential GH Contact 2 (stage 2) Other Versions For switches with alternative tapped cable entries (such as NPT), consult your local sales office. 36 10/2009 © 1998–2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com PH2 setting (rising pressure) Rising pressure 14 13 12 11 24 23 22 21 Selection and Specifications Industrial Pressure Switches XML Electromechanical Pressure Switches Table 26: Size 2.5 bar (36.25 psi) Fixed differential, for detection of a single threshold Switches with 1 C/O single-pole contact Pressure connection 1/2" NPT or 1/4" BSP Pressure Switches, Type XMLA With setting scale Without setting scale Adjustable Range of Operating Point (PH) 0.15–2.5 bar (2.17–36.25 psi) (Rising pressure) Electrical Connection Terminals DIN connector Terminals DIN connector (1) Catalog Numbers Hydraulic oils, fresh water, sea XMLA002A2S13 XMLA002A2C11 XMLA002A1S13 XMLA002A1C11 water, air, up to 158 °F (70 °C) Fluids Controlled Hydraulic oils, fresh water, sea XMLA002B2S13 XMLA002B2C11 XMLA002B1S13 XMLA002B1C11 water, air, up to 320 °F (160 °C) (2) Corrosive fluids, up to 320 °F XMLA002C2S13 XMLA002C2C11 XMLA002C1S13 XMLA002C1C11 (160 °C) Weight, lb (kg) 2.19 (0.995) 2.23 (1.010) 2.19 (0.995) 2.23 (1.010) Supplementary Specifications (not shown under general specifications) At low setting 0.13 bar (1.88 psi), ±0.03 bar (±0.43 psi) Inherent Differential (subtract from PH to get PB) At high setting 0.13 bar (1.88 psi), ±0.03 bar (±0.43 psi) Per cycle 5 bar (72.5 psi) Maximum Allowable Pressure Accidental 9 bar (130.5 psi) Destruction Pressure 18 bar (261 psi) Cable Entry and Wire Size for Terminal Models 1/2" NPT, 1 x 0.2 mm² minimum, 2 x 2.5 mm² maximum. Connector Type for Connector Models DIN 43650A, 4-pin male. For suitable female connector, see page 73. Pressure Switch Style Diaphragm (1) For 1 entry tapped for PG 13.5 conduit/cable entry, replace S13 with S11 (example: XMLA002A2S13 becomes XMLA002A2S11). (2) Component materials of units in contact with the fluid, see pages 77–78. Operating Curves Connection Terminal Model bar Pressure 2.5 PH 2 PB Connector model Pressure switch connector pin view 1 1 →11 and 13 Time 2 →12 1 2 3 3 →14 –– Adjustable value 0.15 --- Non adjustable value 0 0.02 1 22.37 bar Falling pressure Other Versions For switches with alternative tapped cable entries (such as NPT), consult your local sales office. 37 © 1998–2009 Schneider Electric 10/2009 All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Rising pressure 14 13 12 11 Selection and Specifications Industrial Pressure Switches XML Electromechanical Pressure Switches Table 27: Size 2.5 bar (36.25 psi) Adjustable differential, for regulation between two thresholds Switches with 1 C/O single-pole contact Pressure connection 1/2" NPT or 1/4" BSP Pressure Switches, Type XMLB With setting scale Without setting scale With setting scale 30 bar (435 psi) overpressure Adjustable Range of Operating Point (PH) 0.3–2.5 bar (4.35–36.25 psi) (Rising pressure) Electrical Connection Terminals DIN connector Terminals DIN connector Terminals (1) Catalog Numbers Hydraulic oils, fresh water, sea XMLB002A2S13 XMLB002A2C11 XMLB002A1S13 XMLB002A1C11 — water, air, up to 158 °F (70 °C) Hydraulic oils, fresh water, sea XMLB002B2S13 XMLB002B2C11 XMLB002B1S13 XMLB002B1C11 — Fluids Controlled water, air, up to 320 °F (160 °C) (2) Hydraulic oils, fresh water, air, — XMLBS02B2S13 up to 320 °F (160 °C) Corrosive fluids, up to 320 °F XMLB002C2S13 XMLB002C2C11 XMLB002C1S13 XMLB002C1C11 — (160 °C) Weight, lb (kg) 2.24 (1.015) 2.27 (1.030) 2.24 (1.015) 2.27 (1.030) 7.72 (3.500) Supplementary Specifications (not shown under general specifications) 0.1 bar (1.45 psi), Min. at low setting 0.16 bar (2.32 psi), –0.8 mbar, +1.1 mbar (–0.01 psi, +0.02 psi) –0.8 mbar, +1.1 mbar Possible Differential (–0.01 psi, +0.02 psi) (subtract from PH to get 0.22 bar (3.19 psi), Min. at high setting 0.21 bar (3.04 psi), ±1.4 mbar (±0.02 psi) PB) ±1.4 mbar (±0.02 psi) Max. at high setting 1.75 bar (25.37 psi) 1.45 bar (21 psi) Per cycle 5 bar (72.5 psi) 30 bar (435 psi) Maximum Allowable Pressure Accidental 9 bar (130.5 psi) 37.5 bar (543.75 psi) Destruction Pressure 18 bar (261 psi) 67.5 bar (978.75 psi) Cable Entry and Wire Size for Terminal Models 1/2" NPT, 1 x 0.2 mm² minimum, 2 x 2.5 mm² maximum. Connector Type for Connector Models DIN 43650A, 4-pin male. For suitable female connector, see page 73. Pressure Switch Style Diaphragm (1) For 1 entry tapped for PG 13.5 conduit/cable entry, replace S13 with S11 (example: XMLBL05R2S13 becomes XMLBL05R2S11). (2) Component materials of units in contact with the fluid, see pages 77–78. Operating Curves Connection 1 Maximum differential Terminal model bar Pressure 2.5 2 Minimum differential PH 2 1 Connector model PB Pressure switch connector pin view 2 1 1 →11 and 13 2 →12 1 2 Time 3 3 →14 –– Adjustable value 0.3 0 0.14 0.75 1 2 2.29 bar Falling pressure Other Versions For switches with alternative tapped cable entries (such as NPT), consult your local sales office. 38 10/2009 © 1998–2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Rising pressure 14 13 12 11 Selection and Specifications Industrial Pressure Switches XML Electromechanical Pressure Switches Table 28: Size 2.5 bar (36.25 psi) Adjustable differential, for regulation between two thresholds Switches with 2 C/O single-pole contacts Pressure connection 1/2" NPT or 1/4" BSP Pressure Switches, Type XMLC With setting scale With setting scale 30 bar (435 psi) overpressure Adjustable Range of Operating Point (PH) 0.3–2.5 bar (4.35–36.25 psi) (Rising pressure) Electrical Connection Terminals (1) Catalog Numbers Hydraulic oils, fresh water, air, up — XMLCS02B2S13 to 320 °F (160 °C) Fluids Controlled Hydraulic oils, fresh water, sea XMLC002B2S13 — water, air, up to 320 °F (160 °C) (2) Corrosive fluids, up to 320 °F XMLC002C2S13 — (160 °C) Weight, lb (kg) 2.19 (0.995) 7.72 (3.500) Supplementary Specifications (not shown under general specifications) Min. at low setting 0.13 bar (1.89 psi), ±0.02 bar (±0.29 psi) 0.1 bar (1.45 psi), ±0.02 bar (±0.29 psi) Possible Differential Min. at high setting 0.17 bar (2.47 psi), ±0.03 bar (±0.43 psi) 0.18 bar (2.61 psi), ±0.03 bar (±0.43 psi) (subtract from PH to get PB) Max. at high setting 2 bar (29 psi) 1.25 bar (18.12 psi) Per cycle 5 bar (72.5 psi) 30 bar (435 psi) Maximum Allowable Pressure Accidental 9 bar (130.5 psi) 37.5 bar (543.75 psi) Destruction Pressure 18 bar (261 psi) 67.5 bar (978.75 psi) Cable Entry and Wire Size for Terminal Models 1/2" NPT, 1 x 0.2 mm² minimum, 2 x 2.5 mm² maximum. Pressure Switch Style Diaphragm (1) For 1 entry tapped for PG 13.5 conduit/cable entry, replace S13 with S11 (example: XMLC002B2S13 becomes XMLC002B2S11). (2) Component materials of units in contact with the fluid, see pages 77–78. Operating Curves Connection 1 Maximum bar Pressure 2.5 differential PH 2 Minimum 1 differential 2 PB 2 1 Time –– Adjustable value 0.3 0 0.17 0.5 1 22.33 bar Falling pressure Other Versions For switches with alternative tapped cable entries (such as NPT), consult your local sales office. 39 © 1998–2009 Schneider Electric 10/2009 All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Rising pressure 14 13 12 11 24 23 22 21 Selection and Specifications Industrial Pressure Switches XML Electromechanical Pressure Switches Table 29: Size 2.5 bar (36.25 psi) Dual-stage, fixed differential, for detection at each threshold Switches with 2 C/O single-pole contacts (one per stage) Pressure connection 1/2" NPT or 1/4" BSP Pressure Switches, Type XMLD Without setting scale 2nd stage operating point (PH2) 0.34–2.5 bar (4.93–36.25 psi) Adjustable Range of Each Operating Point 1st stage operating point (PH1) 0.2–2.36 bar (2.9–34.22 psi) (Rising pressure) Spread between the Two Stages (PH2–PH1) 0.14–1.5 bar (2.03–21.75 psi) Electrical Connection Terminals (1) Catalog Numbers Hydraulic oils, fresh water, sea XMLD002B1S13 water, air, up to 320 °F (160 °C) Fluids Controlled (2) Corrosive fluids, up to 320 °F XMLD002C1S13 (160 °C) Weight, lb (kg) 2.24 (1.015) Supplementary Specifications (not shown under general specifications) Inherent Differential At low setting 0.14 bar (2.03 psi), ±0.04 bar (±0.58 psi) (subtract from PH1/PH2 At high setting 0.19 bar (2.76 psi), ±0.07 bar (±1.02 psi) to get PB1/PB2) Per cycle 5 bar (72.5 psi) Maximum Allowable Pressure Accidental 9 bar (130.5 psi) Destruction Pressure 18 bar (261 psi) Cable Entry and Wire Size for Terminal Models 1/2" NPT, 1 x 0.2 mm² minimum, 2 x 2.5 mm² maximum. Pressure Switch Style Diaphragm (1) For 1 entry tapped for PG 13.5 conduit/cable entry, replace S13 with S11 (example: XMLD002B1S13 becomes XMLD002B1S11). (2) Component materials of units in contact with the fluid, see pages 77–78. Operating Curves High setting trip points of contacts 1 and 2 Inherent differential of contacts 1 and 2 bar Pressure bar H 2.5 2.5 F PH2 2.36 PB2 1 2 2 PH1 1.69 PB1 2 1 1 Time –– Adjustable value 0.34 0.34 G 0.20 --- Non adjustable value E 0 0 0.2 1 22.36bar 0.06 1 2.17 2.31bar Connection: Terminal model Falling pressure PH1 setting (rising pressure) Contact 2 (stage 2) Contact 1 (stage 1) EF Contact 1 (stage 1) 1 Maximum differential GH Contact 2 (stage 2) 2 Minimum differential Other Versions For switches with alternative tapped cable entries (such as NPT), consult your local sales office. 40 10/2009 © 1998–2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com PH2 setting (rising pressure) Rising pressure 14 13 12 11 24 23 22 21 Selection and Specifications Industrial Pressure Switches XML Electromechanical Pressure Switches Table 30: Size 4 bar (58 psi) Fixed differential, for detection of a single threshold Switches with 1 C/O single-pole contact Pressure connection 1/2" NPT or 1/4" BSP Pressure Switches, Type XMLA With setting scale Without setting scale Adjustable Range of Operating Point (PH) 0.4–4 bar (5.8–58 psi) (Rising pressure) Electrical Connection Terminals DIN connector Terminals DIN connector (1) Catalog Numbers Hydraulic oils, fresh water, sea XMLA004A2S13 XMLA004A2C11 XMLA004A1S13 XMLA004A1C11 water, air, up to 158 °F (70 °C) Hydraulic oils, fresh water, sea XMLA004B2S13 XMLA004B2C11 XMLA004B1S13 XMLA004B1C11 water, air, up to 320 °F (160 °C) Fluids Controlled Corrosive fluids, up to 320 °F (2) XMLA004C2S13 XMLA004C2C11 XMLA004C1S13 XMLA004C1C11 (160 °C) Viscous products, up to 320 °F (160 °C) (G1¼” pressure XMLA004P2S13 XMLA004P2C11 XMLA004P1S13 XMLA004P1C11 connection) Weight, lb (kg) 1.51 (0.685) 1.58 (0.715) 1.51 (0.685) 1.58 (0.715) Supplementary Specifications (not shown under general specifications) At low setting 0.35 bar (5.07 psi), ±0.03 bar (±0.43 psi) Inherent Differential (subtract from PH to get PB) At high setting 0.35 bar (5.07 psi), ±0.03 bar (±0.43 psi) Per cycle 5 bar (72.5 psi) Maximum Allowable Pressure Accidental 9 bar (130.5 psi) Destruction Pressure 18 bar (261 psi) Cable Entry and Wire Size for Terminal Models 1/2" NPT, 1 x 0.2 mm² minimum, 2 x 2.5 mm² maximum. Connector Type for Connector Models DIN 43650A, 4-pin male. For suitable female connector, see page 73. Pressure Switch Style Diaphragm (1) For 1 entry tapped for PG 13.5 conduit/cable entry, replace S13 with S11 (example: XMLA004A2S13 becomes XMLA004A2S11). (2) Component materials of units in contact with the fluid, see pages 77–78. Operation curves Connection Terminal model bar Pressure 4 PH PB 3 Connector model Pressure switch connector pin view 2 1 →11 and 13 2 →12 Time 1 1 2 –– Adjustable value 3 →14 3 0.4 --- Non adjustable value 0 0.05 12 33.654bar Falling pressure Other Versions For switches with alternative tapped cable entries (such as NPT), consult your local sales office. 41 © 1998–2009 Schneider Electric 10/2009 All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Rising pressure 14 13 12 11 Selection and Specifications Industrial Pressure Switches XML Electromechanical Pressure Switches Table 31: Size 4 bar (58 psi) Adjustable differential, for regulation between 2 thresholds Switches with 1 C/O single-pole contact Pressure connection 1/2" NPT or 1/4" BSP Pressure Switches, Type XMLB With setting scale Without setting scale With setting scale 30 bar (435 psi) overpressure Adjustable Range of Operating Point (PH) 0.25–4 bar (3.62–58 psi) (Rising pressure) Electrical Connection Terminals DIN connector Terminals DIN connector Terminals (1) Catalog Numbers Hydraulic oils, fresh water, sea XMLB004A2S13 XMLB004A2C11 XMLB004A1S13 XMLB004A1C11 — water, air, up to 158 °F (70 °C) Hydraulic oils, fresh water, sea XMLB004B2S13 XMLB004B2C11 XMLB004B1S13 XMLB004B1C11 — Fluids Controlled water, air, up to 320 °F (160 °C) (2) Hydraulic oils, freshwater, air, — XMLBS04B2S13 up to 320 °F (160 °C) Corrosive fluids, up to 320 °F XMLB004C2S13 XMLB004C2C11 XMLB004C1S13 XMLB004C1C11 — (160 °C) Weight, lb (kg) 2.24 (1.015) 2.27 (1.030) 2.24 (1.015) 2.27 (1.030) 7.72 (3.500) Supplementary Specifications (not shown under general specifications) 0.15 bar (2.18 psi), Min. at low setting 0.2 bar (2.9 psi), ±0.01 bar (±0.14 psi) ±0.01 bar (±0.14 psi) Possible Differential 0.34 bar (4.93 psi), (subtract from PH to get Min. at high setting 0.25 bar (3.62 psi), –0.03 bar, +0.05 bar (–0.43 psi, +0.72 psi) –0.03 bar, +0.05 bar PB) (–0.43 psi, +0.72 psi) Max. at high setting 2.4 bar (34.8 psi) 2.46 bar (35.67 psi) Maximum Allowable Per cycle 5 bar (72.5 psi) 30 bar (435 psi) Pressure Accidental 9 bar (130.5 psi) 37.5 bar (543.75 psi) Destruction Pressure 18 bar (261 psi) 67.5 bar (978.75 psi) Cable Entry and Wire Size for Terminal Models 1/2" NPT, 1 x 0.2 mm² minimum, 2 x 2.5 mm² maximum. Connector Type for Connector Models DIN 43650A, 4-pin male. For suitable female connector, see page 73. Pressure Switch Style Diaphragm (1) For 1 entry tapped for PG 13.5 conduit/cable entry, replace S13 with S11 (example: XMLB004A2S13 becomes XMLB004A2S11). (2) Component materials of units in contact with the fluid, see pages 77–78. Operating Curves Connection Terminal model bar Pressure 4 PH 3 Connector model 1 PB 2 Pressure switch connector pin view 2 1 →11 and 13 2 →12 Time 1 2 1 3 –– Adjustable value 3 →14 0.25 0 1 Maximum differential 0.05 12 1.6 33.75bar 2 Minimum differential Falling pressure Other Versions For switches with alternative tapped cable entries (such as NPT), consult your local sales office. 42 10/2009 © 1998–2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Rising pressure 14 13 12 11 Selection and Specifications Industrial Pressure Switches XML Electromechanical Pressure Switches Table 32: Size 4 bar (58 psi) Adjustable differential, for regulation between two thresholds Switches with 2 C/O single-pole contacts Pressure connection 1/2" NPT or 1/4" BSP Pressure Switches, Type XMLC With setting scale With setting scale 30 bar (435 psi) overpressure Adjustable Range of Operating Point (PH) 0.3–4 bar (4.35–58 psi) (Rising pressure) Electrical Connection Terminals (1) Catalog Numbers Hydraulic oils, fresh water, air, up — XMLCS04B2S13 to 320 °F (160 °C) Fluids Controlled Hydraulic oils, fresh water, sea XMLC004B2S13 — water, air, up to 320 °F (160 °C) (2) Corrosive fluids, up to 320 °F XMLC004C2S13 — (160 °C) Weight, lb (kg) 1.51 (0.685) 7.72 (3.500) Supplementary Specifications (not shown under general specifications) Min. at low setting 0.15 bar (2.18 psi), ±0.02 bar (±0.29 psi) 0.1 bar (1.45 psi), ±0.02 bar (±0.29 psi) Possible Differential Min. at high setting 0.17 bar (2.47 psi), ±0.02 bar (±0.29 psi) 0.25 bar (3.62 psi), ±0.02 bar (±0.29 psi) (subtract from PH to get PB) Max. at high setting 2.5 bar (36.25 psi) 2.20 bar (31.9 psi) Per cycle 5 bar (72.5 psi) 30 bar (435 psi) Maximum Allowable Pressure Accidental 9 bar (130.5 psi) 37.5 bar (543.75 psi) Destruction Pressure 18 bar (261 psi) 67.5 bar (978.75 psi) Cable Entry and Wire Size for Terminal Models 1/2" NPT, 1 x 0.2 mm² minimum, 2 x 2.5 mm² maximum. Pressure Switch Style Diaphragm (1) For 1 entry tapped for PG 13.5 conduit/cable entry, replace S13 with S11 (example: XMLC004B2S13 becomes XMLC004B2S11). (2) Component materials of units in contact with the fluid, see pages 77–78. Operating Curves Connection 1 Maximum Terminal model bar Pressure 4 differential PH 2 Minimum differential 1 3 PB 2 2 Time 1 –– Adjustable value 0.3 0 0.15 12 1.5 33.83bar Falling pressure Other Versions For switches with alternative tapped cable entries (such as NPT), consult your local sales office. 43 © 1998–2009 Schneider Electric 10/2009 All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Rising pressure 14 13 12 11 24 23 22 21 Selection and Specifications Industrial Pressure Switches XML Electromechanical Pressure Switches Table 33: Size 4 bar (58 psi) Dual-stage, fixed differential, for detection at each threshold Switches with 2 C/O single-pole contacts (one per stage) Pressure connection 1/2" NPT or 1/4" BSP Pressure Switches, Type XMLD Without setting scale Adjustable Range of 2nd stage operating point (PH2) 0.40–4 bar (5.8–58 psi) Each Operating Point 1st stage operating point (PH1) 0.19–3.79 bar (2.76–54.96 psi) (Rising pressure) Spread between the Two Stages (PH2–PH1) 0.21–2.18 bar (3.05–31.61 psi) Electrical Connection Terminals (1) Catalog Numbers Hydraulic oils, fresh water, sea XMLD004B1S13 water, air, up to 320 °F (160 °C) Fluids Controlled (2) Corrosive fluids, up to 320 °F XMLD004C1S13 (160 °C) Weight, lb (kg) 2.24 (1.015) Supplementary Specifications (not shown under general specifications) Inherent Differential At low setting 0.15 bar (2.18 psi), ±0.03 bar (±0.43 psi) (subtract from PH1/PH2 At high setting 0.19 bar (2.76 psi), ±0.03 bar (±0.43 psi) to get PB1/PB2) Per cycle 5 bar (72.5 psi) Maximum Allowable Pressure Accidental 9 bar (130.5 psi) Destruction Pressure 18 bar (261 psi) Cable Entry and Wire Size for Terminal Models 1/2" NPT, 1 x 0.2 mm² minimum, 2 x 2.5 mm² maximum. Pressure Switch Style Diaphragm (1) For 1 entry tapped for PG 13.5 conduit/cable entry, replace S13 with S11 (example: XMLD004B1S13 becomes XMLD004B1S11). (2) Component materials of units in contact with the fluid, see pages 77–78. Operating Curves High setting trip points of contacts 1 and 2 Inherent differential of contacts 1 and 2 1 Maximum bar Pressure bar H 4 differential 4 3.79 PH2 2 Minimum F differential PB2 3 3 PH1 1 PB1 2.35 2 2 2 Time 1 1 EF Contact 1 –– Adjustable value G 0.40 (stage 1) 0.4 --- Non adjustable value 0.19 GH Contact 2 E 0 0 Connection: Terminal model (stage 2) 0.04 12 33.6 3.81bar 0.19 12 1.82 33.79bar Falling pressure PH1 setting (rising pressure) Contact 2 (stage 2) Contact 1 (stage 1) Other Versions For switches with alternative tapped cable entries (such as NPT), consult your local sales office. 44 10/2009 © 1998–2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com PH2 setting (rising pressure) Rising pressure 14 13 12 11 24 23 22 21 Selection and Specifications Industrial Pressure Switches XML Electromechanical Pressure Switches Table 34: Size 10 bar (145 psi) Fixed differential, for detection of a single threshold Switches with 1 C/O single-pole contact Pressure connection 1/2" NPT or 1/4" BSP Pressure Switches, Type XMLA With setting scale Without setting scale Adjustable Range of Operating Point (PH) 0.6–10 bar (8.7–145 psi) (Rising pressure) Electrical Connection Terminals DIN connector Terminals DIN connector (1) Catalog Numbers Hydraulic oils, fresh water, sea XMLA010A2S13 XMLA010A2C11 XMLA010A1S13 XMLA010A1C11 water, air, up to 158 °F (70 °C) Hydraulic oils, fresh water, sea XMLA010B2S13 XMLA010B2C11 XMLA010B1S13 XMLA010B1C11 water, air, up to 320 °F (160 °C) Fluids Controlled Corrosive fluids, up to 320 °F (2) XMLA010C2S13 XMLA010C2C11 XMLA010C1S13 XMLA010C1C11 (160 °C) Viscous products, up to 320 °F (160 °C) (G1¼” pressure XMLA010P2S13 XMLA010P2C11 XMLA010P1S13 XMLA010P1C11 connection) Weight, lb (kg) 1.51 (0.685) 1.58 (0.715) 1.51 (0.685) 1.58 (0.715) Supplementary Specifications (not shown under general specifications) At low setting 0.5 bar (7.25 psi), ±0.05 bar (±0.72 psi) Inherent Differential (subtract from PH to get PB) At high setting 0.5 bar (7.25 psi), ±0.05 bar (±0.72 psi) Per cycle 12.5 bar (181.25 psi) Maximum Allowable Pressure Accidental 22.5 bar (326.25 psi) Destruction Pressure 45 bar (652.5 psi) Cable Entry and Wire Size for Terminal Models 1/2" NPT, 1 x 0.2 mm² minimum, 2 x 2.5 mm² maximum. Connector Type for Connector Models DIN 43650A, 4-pin male. For suitable female connector, see page 73. Pressure Switch Style Diaphragm (1) For 1 entry tapped for PG 13.5 conduit/cable entry, replace S13 with S11 (example: XMLA010A2S13 becomes XMLA010A2S11). (2) Component materials of units in contact with the fluid, see pages 77–78. Operating Curves Connection Terminal model bar Pressure 10 PH 8 PB Connector model 6 Pressure switch connector pin view 4 1 →11 and 13 Time 2 →12 1 2 2 –– Adjustable value 3 3 →14 1 --- Non adjustable value 0.6 0 0.1 2 4 6 8 9.5 bar Falling pressure Other Versions For switches with alternative tapped cable entries (such as NPT), consult your local sales office. 45 © 1998–2009 Schneider Electric 10/2009 All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Rising pressure 14 13 12 11 Selection and Specifications Industrial Pressure Switches XML Electromechanical Pressure Switches Table 35: Size 10 bar (145 psi) Adjustable differential, for regulation between two thresholds Switches with 1 C/O single-pole contact Pressure connection 1/2" NPT or 1/4" BSP Pressure Switches, Type XMLB With setting scale Without setting scale With setting scale 30 bar (435 psi) overpressure Adjustable Range of Operating Point (PH) 0.7–10 bar (10.15–145 psi) (Rising pressure) Terminals DIN connector Terminals DIN connector Terminals Electrical Connection (1) Catalog Numbers Hydraulic oils, fresh water, sea XMLB010A2S13 XMLB010A2C11 XMLB010A1S13 XMLB010A1C11 — water, air, up to 158 °F (70 °C) Hydraulic oils, fresh water, air, ———— XMLBS10A2S13 up to 320 °F (160 °C) Hydraulic oils, fresh water, air, Fluids Controlled XMLB010B2S13 XMLB010B2C11 XMLB010B1S13 XMLB010B1C11 — up to 320 °F (160 °C) (2) Corrosive fluids, up to 320 °F XMLB010C2S13 XMLB010C2C11 XMLB010C1S13 XMLB010C1C11 — (160 °C) Viscous products, up to 320 °F (160 °C) XMLB010P2S13 XMLB010P2C11 XMLB010P1S13 XMLB010P1C11 — (G1¼” pressure connection) Weight, lb (kg) 1.55 (0.705) 1.62 (0.735) 1.55 (0.705) 1.62 (0.735) 7.72 (3.500) Supplementary Specifications (not shown under general specifications) 0.45 bar (6.52 psi), Min. at low setting 0.57 bar (8.26 psi), ±0.05 bar (±0.72 psi). ±0.05 bar (±0.72 psi). Possible Differential 0.85 bar (12.32 psi), (subtract from PH Min. at high setting 0.85 bar (12.32 psi), –0.1 bar, +0.15 bar (–1.45 psi, +2.17 psi) –0.1 bar, +0.15 bar to get PB) (–1.45 psi, +2.17 psi) Max. at high setting 7.5 bar (108.75 psi) 6.25 bar (90.62 psi) Per cycle 12.5 bar (181.25 psi) 30 bar (435 psi) Maximum Allowable Accidental 22.5 bar (326.25 psi) 37.5 bar (543.75 psi) Pressure Destruction Pressure 45 bar (652.5 psi) 67.5 bar (978.75 psi) 1/2" NPT, 1 x 0.2 mm² minimum, 2 x 2.5 mm² maximum. Cable Entry and Wire Size for Terminal Models Connector Type for Connector Models DIN 43650A, 4-pin male. For suitable female connector, see page 73. Diaphragm Pressure Switch Style (1) For 1 entry tapped for PG 13.5 conduit/cable entry, replace S13 with S11 (example: XMLB010A2S13 becomes XMLB010A2S11). (2) Component materials of units in contact with the fluid, see pages 77–78. Operating Curves Connection 1 Maximum differential Terminal model bar Pressure 10 2 Minimum differential PH 8 PB Connector model 6 Pressure switch connector pin view 1 →11 and 13 4 2 →12 1 2 3 →14 Time 3 2 –– Adjustable value 1 0.6 0 0.1 2 4 6 8 9.5 bar Falling pressure Other Versions For switches with alternative tapped cable entries (such as NPT), consult your local sales office. 46 10/2009 © 1998–2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Rising pressure 14 13 12 11 Selection and Specifications Industrial Pressure Switches XML Electromechanical Pressure Switches Table 36: Size 10 bar (145 psi) Adjustable differential, for regulation between two thresholds Switches with 2 C/O single-pole contacts Pressure connection 1/2" NPT or 1/4" BSP Pressure Switches, Type XMLC With setting scale With setting scale 30 bar (435 psi) overpressure Adjustable Range of Operating Point (PH) 0.7–10 bar (10.15–145 psi) (Rising pressure) Terminals Electrical Connection (1) Catalog Numbers Hydraulic oils, fresh water, air, — XMLCS10A2S13 up to 158 °F (70 °C) Fluids Controlled Hydraulic oils, fresh water, sea XMLC010B2S13 — water, air, up to 320 °F (160 °C) (2) Corrosive fluids, up to 320 °F XMLC010C2S13 — (160 °C) 1.51 (0.685) 7.72 (3.500) Weight, lb (kg) Supplementary Specifications (not shown under general specifications) Min. at low setting 0.45 bar (6.53 psi), ±0.05 bar (±0.72 psi) 0.25 bar (3.62 psi), ±0.05 bar (±0.72 psi) Possible Differential Min. at high setting 0.70 bar (10.15 psi), ±0.01 bar (±1.45 psi) 0.65 bar (9.42 psi), ±0.01 bar (±1.45 psi) (subtract from PH to get PB) Max. at high setting 8 bar (116 psi) 5.6 bar (81.2 psi) Per cycle 12.5 bar (181.25 psi) 30 bar (435 psi) Maximum Allowable Pressure Accidental 22.5 bar (326.25 psi) 37.5 bar (543.75 psi) 45 bar (652.5 psi) 67.5 bar (978.75 psi) Destruction Pressure 1/2" NPT, 1 x 0.2 mm² minimum, 2 x 2.5 mm² maximum. Cable Entry and Wire Size for Terminal Models Diaphragm Pressure Switch Style (1) For 1 entry tapped for PG 13.5 conduit/cable entry, replace S13 with S11 (example: XMLC010B2S13 becomes XMLC010B2S11). (2) Component materials of units in contact with the fluid, see pages 77–78. Operating Curves Connection 1 Maximum bar Pressure Terminal model 10 differential 2 Minimum PH 1 differential PB 6 2 4 Time 2 –– Adjustable value 0.7 0 0.25 2 4 6 8 9.3bar Falling pressure Other Versions For switches with alternative tapped cable entries (such as NPT), consult your local sales office. 47 © 1998–2009 Schneider Electric 10/2009 All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Rising pressure 14 13 12 11 24 23 22 21 Selection and Specifications Industrial Pressure Switches XML Electromechanical Pressure Switches Table 37: Size 10 bar (145 psi) Dual-stage, fixed differential, for detection at each threshold Switches with 2 C/O single-pole contacts (one per stage) Pressure connection 1/2" NPT or 1/4" BSP Pressure Switches, Type XMLD Without setting scale 2nd stage operating point Adjustable Range of Each 1.2–10 bar (17.4–145 psi) (PH2) Operating Point 1st stage operating point (PH1) 0.52–9.32 bar (7.54–135.14 psi) (Rising pressure) Spread between the Two Stages (PH2–PH1) 0.68–5.8 bar (9.86–84.1 psi) Electrical Connection Terminals (1) Catalog Numbers Hydraulic oils, fresh water, sea XMLD010B1S13 water, air, up to 320 °F (160 °C) Fluids Controlled (2) Corrosive fluids, up to 320 °F XMLD010C1S13 (160 °C) Weight, lb (kg) 1.55 (0.705) Supplementary Specifications (not shown under general specifications) Inherent Differential At low setting 0.45 bar (6.53 psi), ±0.05 bar (±0.72 psi) (subtract from PH1/PH2 At high setting 0.6 bar (8.7 psi), ±0.1 bar (±1.45 psi) to get PB1/PB2) Per cycle 12.5 bar (181.25 psi) Maximum Allowable Pressure Accidental 22.5 bar (326.25 psi) Destruction Pressure 45 bar (652.5 psi) Cable Entry and Wire Size for Terminal Models 1/2" NPT, 1 x 0.2 mm² minimum, 2 x 2.5 mm² maximum. Pressure Switch Style Diaphragm (1) For 1 entry tapped for PG 13.5 conduit/cable entry, replace S13 with S11 (example: XMLD010B1S13 becomes XMLD010B1S11). (2) Component materials of units in contact with the fluid, see pages 77–78. Operating Curves High setting trip points of contacts 1 and 2 Inherent differential of contacts 1 and 2 bar Pressure bar H 10 10 PH2 9.32 F PB2 8 8 PH1 1 PB1 6.34 6 6 2 4 4 Time 2 2 –– Adjustable value G 1.2 1.2 0.52 --- Non adjustable value E 0 0 Connection 0.07 0.75 2 4 6 8.72 9.4 bar 0.52 2 4.2 6 8 9.32 bar PH1 setting (rising pressure) Falling pressure Terminal model 1 Maximum differential EF Contact 1 (stage 1) Contact 2 (stage 2) Contact 1 (stage 1) 2 Minimum differential GH Contact 2 (stage 2) Other Versions For switches with alternative tapped cable entries (such as NPT), consult your local sales office. 48 10/2009 © 1998–2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com PH2 setting (rising pressure) Rising pressure 14 13 12 11 24 23 22 21 Selection and Specifications Industrial Pressure Switches XML Electromechanical Pressure Switches Table 38: Size 20 bar (290 psi) Fixed differential, for detection of a single threshold Switches with 1 C/O single-pole contact Pressure connection 1/2" NPT or 1/4" BSP Pressure Switches, Type XMLA With setting scale Without setting scale Adjustable Range of Operating Point (PH) 1–20 bar (14.5–290 psi) (Rising pressure) Electrical Connection Terminals DIN connector Terminals DIN connector (1) Catalog Numbers Hydraulic oils, fresh water, sea XMLA020A2S13 XMLA020A2C11 XMLA020A1S13 XMLA020A1C11 water, air, up to 158 °F (70 °C) Hydraulic oils, fresh water, sea XMLA020B2S13 XMLA020B2C11 XMLA020B1S13 XMLA020B1C11 water, air, up to 320 °F (160 °C) Fluids Controlled Corrosive fluids, up to 320 °F (2) XMLA020C2S13 XMLA020C2C11 XMLA020C1S13 XMLA020C1C11 (160 °C) Viscous products, up to 320 °F (160 °C) (G1¼” pressure XMLA020P2S13 XMLA020P2C11 XMLA020P1S13 XMLA020P1C11 connection) Weight, lb (kg) 1.51 (0.685) 1.58 (0.715) 1.51 (0.685) 1.58 (0.715) Supplementary Specifications (not shown under general specifications) At low setting 0.4 bar (5.8 psi), ±0.2 bar (±2.9 psi) Inherent Differential (subtract from PH to get PB) At high setting 1 bar (14.5 psi), ±0.1 bar (±1.45 psi) Per cycle 25 bar (362.5 psi) Maximum Allowable Pressure Accidental 45 bar (652.5 psi) Destruction Pressure 90 bar (1305 psi) Cable Entry and Wire Size for Terminal Models 1/2" NPT, 1 x 0.2 mm² minimum, 2 x 2.5 mm² maximum. Connector Type for Connector Models DIN 43650A, 4-pin male. For suitable female connector, see page 73. Pressure Switch Style Diaphragm (1) For 1 entry tapped for PG 13.5 conduit/cable entry, replace S13 with S11 (example: XMLA020A2S13 becomes XMLA020A2S11). (2) Component materials of units in contact with the fluid, see pages 77–78. Operating Curves Connection Terminal model bar Pressure 20 PH 15 PB Connector model Pressure switch connector pin view 10 5 Time 1 2 1 →11 and 13 –– Adjustable value 3 2 →12 --- Non adjustable value 1 3 →14 0 0.6 510 15 19 bar Falling pressure Other Versions For switches with alternative tapped cable entries (such as NPT), consult your local sales office. 49 © 1998–2009 Schneider Electric 10/2009 All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Rising pressure 14 13 12 11 Selection and Specifications Industrial Pressure Switches XML Electromechanical Pressure Switches Table 39: Size 20 bar (290 psi) Adjustable differential, for regulation between two thresholds Switches with 1 C/O single-pole contact Pressure connection 1/2" NPT or 1/4" BSP Pressure Switches, Type XMLB With setting scale Without setting scale With setting scale 30 bar (435 psi) overpressure Adjustable Range of Operating Point (PH) 1.3–20 bar (18.9–290 psi) (Rising pressure) Electrical Connection Terminals DIN connector Terminals DIN connector Terminals (1) Catalog Numbers Hydraulic oils, fresh water, sea XMLB020A2S13 XMLB020A2C11 XMLB020A1S13 XMLB020A1C11 — water, air, up to 158 °F (70 °C) Hydraulic oils, fresh water, air, up —— —— XMLBS20A2S13 to 320 °F (160 °C) Hydraulic oils, fresh water, air, up Fluids Controlled XMLB020B2S13 XMLB020B2C11 XMLB020B1S13 XMLB020B1C11 — to 320 °F (160 °C) (2) Corrosive fluids, up to 320 °F XMLB020C2S13 XMLB020C2C11 XMLB020C1S13 XMLB020C1C11 — (160 °C) Viscous products, up to 320 °F (160 °C) XMLB020P2S13 XMLB020P2C11 XMLB020P1S13 XMLB020P1C11 — (G1¼” pressure connection) Weight, lb (kg) 1.55 (0.705) 1.62 (0.735) 1.55 (0.705) 1.62 (0.735) 7.72 (3.500) Supplementary Specifications (not shown under general specifications) 0.95 bar (13.78 psi), Min. at low setting 1 bar (14.5 psi), ±0.25 bar (±3.63 psi) ±0.25 bar (±3.63 psi) Possible Differential 1.45 bar (21.03 psi), (subtract from PH Min. at high setting 1.6 bar (23.20 psi), ±0.25 bar (±3.63 psi) ±0.25 bar (±3.63 psi) to get PB) Max. at high setting 11 bar (159.5 psi) 12.6 bar (182.7 psi) Maximum Allowable Per cycle 25 bar (362.5 psi) 30 bar (435 psi) Pressure Accidental 45 bar (652.5 psi) 37.5 bar (543.75 psi) Destruction Pressure 90 bar (1305 psi) 67.5 bar (978.75 psi) 1/2" NPT, 1 x 0.2 mm² minimum, 2 x 2.5 mm² maximum. Cable Entry and Wire Size for Terminal Models Connector Type for Connector Models DIN 43650A, 4-pin male. For suitable female connector, see page 73. Pressure Switch Style Diaphragm (1) For 1 entry tapped for PG 13.5 conduit/cable entry, replace S13 with S11 (example: XMLB020A2S13 becomes XMLB020A2S11). (2) Component materials of units in contact with the fluid, see pages 77–78. Operating Curves Connection 1 Maximum differential bar Pressure Terminal model 20 2 Minimum differential PH 15 Connector model PB 2 1 Pressure switch connector pin view 10 1 →11 and 13 2 →12 1 2 5 Time 3 3 →14 –– Adjustable value 1.3 0 0.3b 5 15 18.4 ar 9 10 Falling pressure Other Versions For switches with alternative tapped cable entries (such as NPT), consult your local sales office. 50 10/2009 © 1998–2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Rising pressure 14 13 12 11 Selection and Specifications Industrial Pressure Switches XML Electromechanical Pressure Switches Table 40: Size 20 bar (290 psi) Adjustable differential, for regulation between two thresholds Switches with 2 C/O single-pole contacts Pressure connection 1/2" NPT or 1/4" BSP Pressure Switches, Type XMLC With setting scale With setting scale 30 bar (435 psi) overpressure Adjustable Range of Operating Point (PH) 1.3–20 bar (18.85–290 psi) (Rising pressure) Electrical Connection Terminals (1) Catalog Numbers Hydraulic oils, fresh water, air, — XMLCS20A2S13 up to 158 °F (70 °C) Fluids Controlled Hydraulic oils, fresh water, sea XMLC020B2S13 — water, air, up to 320 °F (160 °C) (2) Corrosive fluids, up to 320 °F XMLC020C2S13 — (160 °C) Weight, lb (kg) 1.51 (0.685) 7.72 (3.500) Supplementary Specifications (not shown under general specifications) Min. at low setting 0.7 bar (10.15 psi), ±0.2 bar (±2.9 psi) 0.7 bar (10.15 psi), ±0.2 bar (±2.9 psi) Possible Differential Min. at high setting 1 bar (14.5 psi), ±0.2 bar (±2.9 psi) 1.15 bar (16.67 psi), ±0.2 bar (±2.9 psi) (subtract from PH to get PB) Max. at high setting 11 bar (159.5 psi) 11.70 bar (169.6 psi) Per cycle 25 bar (362.5 psi) 30 bar (435 psi) Maximum Allowable Pressure Accidental 45 bar (652.5 psi) 37.5 bar (543.75 psi) Destruction Pressure 90 bar (1305 psi) 67.5 bar (978.75 psi) Cable Entry and Wire Size for Terminal Models 1/2" NPT, 1 x 0.2 mm² minimum, 2 x 2.5 mm² maximum. Pressure Switch Style Diaphragm (1) For 1 entry tapped for PG 13.5 conduit/cable entry, replace S13 with S11 (example: XMLC020B2S13 becomes XMLC020B2S11). (2) Component materials of units in contact with the fluid, see pages 77–78. Operating Curves Connection 1 Maximum Terminal model bar Pressure 20 differential 2 Minimum PH differential 15 PB 1 2 10 Time 5 –– Adjustable value 1.3 0 0.6 5 910 15 19 bar Falling pressure Other Versions For switches with alternative tapped cable entries (such as NPT), consult your local sales office. 51 © 1998–2009 Schneider Electric 10/2009 All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Rising pressure 14 13 12 11 24 23 22 21 Selection and Specifications Industrial Pressure Switches XML Electromechanical Pressure Switches Table 41: Size 20 bar (290 psi) Dual-stage, fixed differential, for detection at each threshold Switches with 2 C/O single-pole contacts (one per stage) Pressure connection 1/2" NPT or 1/4" BSP Pressure Switches, Type XMLD Without setting scale Adjustable Range of 2nd stage operating point (PH2) 2.14–20 bar (31.03–290 psi) Each Operating Point 1st stage operating point (PH1) 0.9–18.76 bar (13.05–272.02 psi) (Rising pressure) Spread between the Two Stages (PH2–PH1) 1.24–9.55 bar (17.98–138.48 psi) Electrical Connection Terminals (1) Catalog Numbers Hydraulic oils, fresh water, sea water, XMLD020B1S13 Fluids Controlled air, up to 320 °F (160 °C) (2) Corrosive fluids, up to 320 °F (160 °C) XMLD020C1S13 Weight, lb (kg) 1.55 (0.705) Supplementary Specifications (not shown under general specifications) Inherent Differential At low setting 0.7 bar (10.15 psi), ±0.15 bar (±2.18 psi) (subtract from PH1/PH2 At high setting 1.3 bar (18.85 psi), ±0.3 bar (±4.35 psi) to get PB1/PB2) Per cycle 25 bar (362.5 psi) Maximum Allowable Pressure Accidental 45 bar (652.5 psi) 90 bar (1305 psi) Destruction Pressure 1/2" NPT, 1 x 0.2 mm² minimum, 2 x 2.5 mm² maximum. Cable Entry and Wire Size for Terminal Models Diaphragm Pressure Switch Style (1) For 1 entry tapped for PG 13.5 conduit/cable entry, replace S13 with S11 (example: XMLD020B1S13 becomes XMLD020B1S11). (2) Component materials of units in contact with the fluid, see pages 77–78. Operating Curves High setting trip points of contacts 1 and 2 Inherent differential of contacts 1 and 2 Pressure bar bar H 20 20 PH2 18.76 F PB2 15 15 PH1 PB1 1 2 10.6 10 Time 5 5 –– Adjustable value G 2.14 2.14 --- Non adjustable value 0.9 E 0 0 Connection bar 0.2 1.44510 15 17.46 18.7bar 0.9 5 10.45 15 18.76 Falling pressure PH1 setting (rising pressure) Terminal model EF Contact 1 (stage 1) 1 Maximum differential Contact 2 (stage 2) Contact 1 (stage 1) GH Contact 2 (stage 2) 2 Minimum differential For switches with alternative tapped cable entries (such as NPT), Other Versions consult your local sales office. 52 10/2009 © 1998–2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com PH2 setting (rising pressure) Rising pressure 14 13 12 11 24 23 22 21 Selection and Specifications Industrial Pressure Switches XML Electromechanical Pressure Switches Table 42: Size 35 bar (507.5 psi) Fixed differential, for detection of a single threshold Switches with 1 C/O single-pole contact Pressure connection 1/2" NPT or 1/4" BSP Pressure Switches, Type XMLA With setting scale Without setting scale Adjustable Range of Operating Point (PH) 1.5–35 bar (21.75–507.5 psi) (Rising pressure) Electrical Connection Terminals DIN connector Terminals DIN connector (1) Catalog Numbers Hydraulic oils, fresh water, sea XMLA035A2S13 XMLA035A2C11 XMLA035A1S13 XMLA035A1C11 water, air, up to 158 °F (70 °C) Hydraulic oils, fresh water, sea XMLA035B2S13 XMLA035B2C11 XMLA035B1S13 XMLA035B1C11 water, air, up to 320 °F (160 °C) Fluids Controlled Corrosive fluids, up to 320 °F (2) XMLA035C2S13 XMLA035C2C11 XMLA035C1S13 XMLA035C1C11 (160 °C) Viscous products, up to 320 °F (160 °C) XMLA035P2S13 XMLA035P2C11 XMLA035P1S13 XMLA035P1C11 (G1¼” pressure connection) Weight, lb (kg) 1.53 (0.695) 1.60 (0.725) 1.53 (0.695) 1.60 (0.725) Supplementary Specifications (not shown under general specifications) At low setting 1.25 bar (18.12 psi), ±0.25 bar (±3.62 psi) Inherent Differential (subtract from PH to get PB) At high setting 1.25 bar (18.12 psi), ±0.25 bar (±3.62 psi) Per cycle 45 bar (652.5 psi) Maximum Allowable Pressure Accidental 80 bar (1160 psi) Destruction Pressure 160 bar (2320 psi) Cable Entry and Wire Size for Terminal Models 1/2" NPT, 1 x 0.2 mm² minimum, 2 x 2.5 mm² maximum. Connector Type for Connector Models DIN 43650A, 4-pin male. For suitable female connector, see page 73. Pressure Switch Style Diaphragm (1) For 1 entry tapped for PG 13.5 conduit/cable entry, replace S13 with S11 (example: XMLA035A2S13 becomes XMLA035A2S11). (2) Component materials of units in contact with the fluid, see pages 77–78. Operating Curves Connection Terminal model bar Pressure 35 PH 30 PB Connector model 20 Pressure switch connector pin view 1 →11 and 13 10 Time 2 →12 1 2 –– Adjustable value 3 3 →14 --- Non adjustable value 1.5 0 0.25 10 20 30 33.75bar Falling pressure For switches with alternative tapped cable entries (such as NPT), consult your local sales office. Other Versions 53 © 1998–2009 Schneider Electric 10/2009 All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Rising pressure 14 13 12 11 Selection and Specifications Industrial Pressure Switches XML Electromechanical Pressure Switches Table 43: Size 35 bar (507.5 psi) Adjustable differential, for regulation between two thresholds Switches with 1 C/O single-pole contact Pressure connection 1/2" NPT or 1/4" BSP Pressure Switches, Type XMLB With setting scale Without setting scale Adjustable Range of Operating Point (PH) 3.5–35 bar (50.75–507.5 psi) (Rising pressure) Electrical Connection Terminals DIN connector Terminals DIN connector (1) Catalog Numbers Hydraulic oils, fresh water, sea XMLB035A2S13 XMLB035A2C11 XMLB035A1S13 XMLB035A1C11 water, air, up to 158 °F (70 °C) Hydraulic oils, fresh water, sea XMLB035B2S13 XMLB035B2C11 XMLB035B1S13 XMLB035B1C11 water, air, up to 320 °F (160 °C) Fluids Controlled (2) Corrosive fluids, up to 320 °F XMLB035C2S13 XMLB035C2C11 XMLB035C1S13 XMLB035C1C11 (160 °C) Viscous products, up to 320 °F XMLB035P2S13 XMLB035P2C11 XMLB035P1S13 XMLB035P1C11 (160 °C) (G1¼” pressure connection) Weight, lb (kg) 1.58 (0.715) 1.64 (0.745) 1.58 (0.715) 1.64 (0.745) Supplementary Specifications (not shown under general specifications) Min. at low setting 1.7 bar (24.65 psi), –0.5 bar, +0.7 bar (–7.25 psi, +10.15 psi) Possible Differential Min. at high setting 2.55 bar (36.97 psi), –0.5 bar, +0.7 bar (–7.25 psi, +10.15 psi) (subtract from PH to get PB) Max. at high setting 20 bar (290 psi) Per cycle 45 bar (652.5 psi) Maximum Allowable Pressure Accidental 80 bar (1160 psi) Destruction Pressure 160 bar (2320 psi) Cable Entry and Wire Size for Terminal Models 1/2" NPT, 1 x 0.2 mm² minimum, 2 x 2.5 mm² maximum. Connector Type for Connector Models DIN 43650A, 4-pin male. For suitable female connector, see page 73. Pressure Switch Style Diaphragm (1) For 1 entry tapped for PG 13.5 conduit/cable entry, replace S13 with S11 (example: XMLB035A2S13 becomes XMLB035A2S11). (2) Component materials of units in contact with the fluid, see pages 77–78. Operating Curves Connection Terminal model bar Pressure 35 PH 30 1 PB Connector model 2 20 Pressure switch connector pin view 1 →11 and 13 10 2 →12 Time 1 2 3 →14 –– Adjustable value 3 3.5 0 1 Maximum differential 1.8 10 15 20 32.45 bar 2 Minimum differential Falling pressure Other Versions For switches with alternative tapped cable entries (such as NPT), consult your local sales office. 54 10/2009 © 1998–2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Rising pressure 14 13 12 11 Selection and Specifications Industrial Pressure Switches XML Electromechanical Pressure Switches Table 44: Size 35 bar (507.5 psi) Adjustable differential, for regulation between two thresholds Switches with 2 C/O single-pole contacts Pressure connection 1/2" NPT or 1/4" BSP Pressure Switches, Type XMLC With setting scale Adjustable Range of Operating Point (PH) 3.5–35 bar (50.75–507.5 psi) (Rising pressure) Electrical Connection Terminals (1) Catalog Numbers Hydraulic oils, fresh water, sea XMLC035B2S13 water, air, up to 320 °F (160 °C) Fluids Controlled (2) Corrosive fluids, up to 320 °F XMLC035C2S13 (160 °C) Weight, lb (kg) 1.53 (0.695) Supplementary Specifications (not shown under general specifications) Min. at low setting 1 bar (14.5 psi), ±0.2 bar (±2.9 psi) Possible Differential Min. at high setting 1.5 bar (21.75 psi), ±0.5 bar (±7.25 psi) (subtract from PH to get PB) Max. at high setting 22 bar (319 psi) Per cycle 45 bar (652.5 psi) Maximum Allowable Pressure Accidental 80 bar (1160 psi) Destruction Pressure 160 bar (2320 psi) Cable Entry and Wire Size for Terminal Models 1/2" NPT, 1 x 0.2 mm² minimum, 2 x 2.5 mm² maximum. Pressure Switch Style Diaphragm (1) For 1 entry tapped for PG 13.5 conduit/cable entry, replace S13 with S11 (example: XMLC035B2S13 becomes XMLC035B2S11). (2) Component materials of units in contact with the fluid, see pages 77–78. Operating Curves Connection 1 Maximum Terminal model bar Pressure 35 differential PH 2 Minimum 30 differential 1 PB 2 20 10 Time –– Adjustable value 3.5 0 2.5 10 13 20 33.5 bar Falling pressure Other Versions For switches with alternative tapped cable entries (such as NPT), consult your local sales office. 55 © 1998–2009 Schneider Electric 10/2009 All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Rising pressure 14 13 12 11 24 23 22 21 Selection and Specifications Industrial Pressure Switches XML Electromechanical Pressure Switches Table 45: Size 35 bar (507.5 psi) Dual-stage, fixed differential, for detection at each threshold Switches with 2 C/O single-pole contacts (one per stage) Pressure connection 1/2" NPT or 1/4" BSP Pressure Switches, Type XMLD Without setting scale 2nd stage operating point Adjustable Range of Each 4.4–35 bar (63.8–507.5 psi) (PH2) Operating Point 1st stage operating point (PH1) 1.9–32.5 bar (27.55–471.25 psi) (Rising pressure) Spread between the Two Stages (PH2–PH1) 2.5–20.4 bar (36.25–295.8 psi) Electrical Connection Terminals (1) Catalog Numbers Hydraulic oils, fresh water, sea XMLD035B1S13 water, air, up to 320 °F (160 °C) Fluids Controlled (2) Corrosive fluids, up to 320 °F XMLD035C1S13 (160 °C) Weight, lb (kg) 1.58 (0.715) Supplementary Specifications (not shown under general specifications) Inherent Differential At low setting 1.5 bar (21.75 psi), ±0.3 bar (±4.35 psi) (subtract from PH1/PH2 At high setting 2.6 bar (37.7 psi), ±0.7 bar (±10.15 psi) to get PB1/PB2) Per cycle 45 bar (652.5 psi) Maximum Allowable Pressure Accidental 80 bar (1160 psi) Destruction Pressure 160 bar (2320 psi) Cable Entry and Wire Size for Terminal Models 1/2" NPT, 1 x 0.2 mm² minimum, 2 x 2.5 mm² maximum. Pressure Switch Style Diaphragm (1) For 1 entry tapped for PG 13.5 conduit/cable entry, replace S13 with S11 (example: XMLD035B1S13 becomes XMLD035B1S11). (2) Component materials of units in contact with the fluid, see pages 77–78. Operating Curves High setting trip points of contacts 1 and 2 Inherent differential of contacts 1 and 2 bar Pressure bar 35 35 H F PH2 32.5 30 30 PB2 1 PH1 22.3 PB1 2 20 20 10 10 Time G 4.4 4.4 –– Adjustable value 1.9 E --- Non adjustable value 0 0 30 0.4 2.9 10 20 29.9 32.4 bar 1.9 10 14.6 20 32.5 bar Connection PH1 setting (rising pressure) Falling pressure Terminal model 1 Maximum differential EF Contact 1 (stage 1) Contact 2 (stage 2) Contact 1 (stage 1) 2 Minimum differential GH Contact 2 (stage 2) Other Versions For switches with alternative tapped cable entries (such as NPT), consult your local sales office. 56 10/2009 © 1998–2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com PH2 setting (rising pressure) Rising pressure 14 13 12 11 24 23 22 21 Selection and Specifications Industrial Pressure Switches XML Electromechanical Pressure Switches Table 46: Size 70 bar (1015 psi) Fixed differential, for detection of a single threshold Switches with 1 C/O single-pole contact Pressure connection 1/2" NPT or 1/4" BSP Pressure Switches, Type XMLA With setting scale Without setting scale Adjustable Range of Operating Point (PH) 5–70 bar (72.5–1015 psi) (Rising pressure) Electrical Connection Terminals DIN connector Terminals DIN connector (1) Catalog Numbers Hydraulic oils, up to 320 °F XMLA070D2S13 XMLA070D2C11 XMLA070D1S13 XMLA070D1C11 (160 °C) Fluids Controlled Fresh water, sea water, up to XMLA070E2S13 XMLA070E2C11 XMLA070E1S13 XMLA070E1C11 320 °F (160 °C) (2) Corrosive fluids, air, up to XMLA070N2S13 XMLA070N2C11 XMLA070N1S13 XMLA070N1C11 320 °F (160 °C) Weight, lb (kg) 1.53 (0.695) 1.60 (0.725) 1.53 (0.695) 1.60 (0.725) Supplementary Specifications (not shown under general specifications) At low setting 3 bar (43.5 psi), ±1 bar (±14.5 psi) Inherent Differential (subtract from PH to get PB) At high setting 7.5 bar (108.75 psi), ±1 bar (±14.5 psi) Per cycle 90 bar (1035 psi) Maximum Allowable Pressure Accidental 160 bar (2320 psi) Destruction Pressure 320 bar (4640 psi) Cable Entry and Wire Size for Terminal Models 1/2" NPT, 1 x 0.2 mm² minimum, 2 x 2.5 mm² maximum. Connector Type for Connector Models DIN 43650A, 4-pin male. For suitable female connector, see page 73. Pressure Switch Style Piston (1) For 1 entry tapped for PG 13.5 conduit/cable entry, replace S13 with S11 (example: XMLA070D2S13 becomes XMLA070D2S11). (2) Component materials of units in contact with the fluid, see pages 77–78. Operating Curves Connection Terminal model bar Pressure 70 PH 60 PB Connector model 40 Pressure switch connector pin view 1 →11 and 13 20 Time 2 →12 1 2 3 3 →14 –– Adjustable value 5 --- Non adjustable value 0 02 8 20 40 62.5 bar Falling pressure Other Versions For switches with alternative tapped cable entries (such as NPT), consult your local sales office. 57 © 1998–2009 Schneider Electric 10/2009 All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Rising pressure 14 13 12 11 Selection and Specifications Industrial Pressure Switches XML Electromechanical Pressure Switches Table 47: Size 70 bar (1015 psi) Adjustable differential, for regulation between two thresholds Switches with 1 C/O single-pole contact Pressure connection 1/2" NPT or 1/4" BSP Pressure Switches, Type XMLB With setting scale Without setting scale Adjustable Range of Operating Point (PH) 7–70 bar (101.5–1015 psi) (Rising pressure) Electrical Connection Terminals DIN connector Terminals DIN connector (1) Catalog Numbers Hydraulic oils, up to 320 °F XMLB070D2S13 XMLB070D2C11 XMLB070D1S13 XMLB070D1C11 (160 °C) Fluids Controlled Fresh water, sea water, XMLB070E2S13 XMLB070E2C11 XMLB070E1S13 XMLB070E1C11 up to 320 °F (160 °C) (2) Corrosive fluids, air, XMLB070N2S13 XMLB070N2C11 XMLB070N1S13 XMLB070N1C11 up to 320 °F (160 °C) Weight, lb (kg) 1.58 (0.715) 1.64 (0.745) 1.58 (0.715) 1.64 (0.745) Supplementary Specifications (not shown under general specifications) Min. at low setting 4.7 bar (68.15 psi), –0.4 bar, +0.7 bar (–5.8 psi, +10.15 psi) Possible Differential Min. at high setting 8.8 bar (127.6 psi), –0.6 bar, +0.8 bar (–8.7 psi, +11.6 psi) (subtract from PH to get PB) Max. at high setting 50 bar (725 psi) Per cycle 90 bar (1035 psi) Maximum Allowable Pressure Accidental 160 bar (2320 psi) Destruction Pressure 320 bar (4640 psi) Cable Entry and Wire Size for Terminal Models 1/2" NPT, 1 x 0.2 mm² minimum, 2 x 2.5 mm² maximum. Connector Type for Connector Models DIN 43650A, 4-pin male. For suitable female connector, see page 73. Pressure Switch Style Piston (1) For 1 entry tapped for PG 13.5 conduit/cable entry, replace S13 with S11 (example: XMLB070D2S13 becomes XMLB070D2S11). (2) Component materials of units in contact with the fluid, see pages 77–78. Operating Curves Connection 1 Maximum Terminal model bar Pressure 70 differential 2 Minimum PH 60 differential 1 Connector model PB 40 2 Pressure switch connector pin view 1 →11 and 13 20 12 Time 2 → 1 2 –– Adjustable value 3 3 →14 7 0 bar 2.3 20 40 61.2 Falling pressure Other Versions For switches with alternative tapped cable entries (such as NPT), consult your local sales office. 58 10/2009 © 1998–2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Rising pressure 14 13 12 11 Selection and Specifications Industrial Pressure Switches XML Electromechanical Pressure Switches Table 48: Size 70 bar (1015 psi) Adjustable differential, for regulation between two thresholds Switches with 2 C/O single-pole contacts Pressure connection 1/2" NPT or 1/4" BSP Pressure Switches, Type XMLC With setting scale Adjustable Range of Operating Point (PH) 7–70 bar (101.5–1015 psi) (Rising pressure) Electrical Connection Terminals (1) Catalog Numbers Hydraulic oils, up to 320 °F XMLC070D2S13 (160 °C) Fluids Controlled Fresh water, sea water, up to XMLC070E2S13 320 °F (160 °C) (2) Corrosive fluids, up to 320 °F XMLC070N2S13 (160 °C) Weight, lb (kg) 1.53 (0.695) Supplementary Specifications (not shown under general specifications) Min. at low setting 4.5 bar (65.25 psi), ±0.8 bar (±11.6 psi) Possible Differential Min. at high setting 8.9 bar (129.05 psi), ±0.8 bar (±11.6 psi) (subtract from PH to get PB) Max. at high setting 60 bar (870 psi) Per cycle 90 bar (1035 psi) Maximum Allowable Pressure Accidental 160 bar (2320 psi) Destruction Pressure 320 bar (4640 psi) Cable Entry and Wire Size for Terminal Models 1/2" NPT, 1 x 0.2 mm² minimum, 2 x 2.5 mm² maximum. Pressure Switch Style Piston (1) For 1 entry tapped for PG 13.5 conduit/cable entry, replace S13 with S11 (example: XMLC070D2S13 becomes XMLC070D2S11). (2) Component materials of units in contact with the fluid, see pages 77–78. Operating Curves Connection 1 Maximum Terminal model bar Pressure 70 differential 2 Minimum PH 60 differential 1 PB 40 2 20 Time –– Adjustable value 7 0 2.5 10 20 40 61.1 bar Falling pressure Other Versions For switches with alternative tapped cable entries (such as NPT), consult your local sales office. 59 © 1998–2009 Schneider Electric 10/2009 All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Rising pressure 14 13 12 11 24 23 22 21 Selection and Specifications Industrial Pressure Switches XML Electromechanical Pressure Switches Table 49: Size 70 bar (1015 psi) Dual-stage, fixed differential, for detection at each threshold Switches with 2 C/O single-pole contacts (one per stage) Pressure connection 1/2" NPT or 1/4" BSP Pressure Switches, Type XMLD Without setting scale 2nd stage operating point (PH2) 9.4–70 bar (136.3–1015 psi) Adjustable Range of Each Operating Point 1st stage operating point (PH1) 6.6–67.2 bar (95.7–974.4 psi) (Rising pressure) Spread between the Two Stages (PH2–PH1) 2.8–46 bar (40.6–667 psi) Electrical Connection Terminals (1) Catalog Numbers Hydraulic oils, up to 320 °F (160 °C) XMLD070D1S13 Fresh water, sea water, up to 320 °F Fluids Controlled XMLD070E1S13 (160 °C) (2) Corrosive fluids, air, up to 320 °F XMLD070N1S13 (160 °C) 1.58 (0.715) Weight, lb (kg) Supplementary Specifications (not shown under general specifications) Inherent Differential At low setting 5 bar (72.5 psi), ±1.5 bar (±21.75 psi) (subtract from PH1/PH2 At high setting 9.5 bar (137.75 psi), ±2 bar (±29 psi) to get PB1/PB2) Per cycle 90 bar (1035 psi) Maximum Allowable Pressure Accidental 160 bar (2320 psi) Destruction Pressure 320 bar (4640 psi) Cable Entry and Wire Size for Terminal Models 1/2" NPT, 1 x 0.2 mm² minimum, 2 x 2.5 mm² maximum. Pressure Switch Style Piston (1) For 1 entry tapped for PG 13.5 conduit/cable entry, replace S13 with S11 (example: XMLD070D1S13 becomes XMLD070D1S11). (2) Component materials of units in contact with the fluid, see pages 77–78. Operating Curves High setting trip points of contacts 1 and 2 Inherent differential of contacts 1 and 2 bar bar Pressure 70 70 H 67.2 PH2 F 60 60 PB2 1 52.6 PH1 PB1 2 40 40 20 20 Time G 9.4 –– Adjustable value 9.4 6.6 E --- Non adjustable value 0 0 Connection 1.6 4.4 20 40 57.7 60.5 bar 6.6 20 24 40 60 67.2 bar Falling pressure PH1 setting (rising pressure) Terminal model EF Contact 1 (stage 1) 1 Maximum differential Contact 2 (stage 2) Contact 1 (stage 1) GH Contact 2 (stage 2) 2 Minimum differential Other Versions For switches with alternative tapped cable entries (such as NPT), consult your local sales office. 60 10/2009 © 1998–2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com PH2 setting (rising pressure) Rising pressure 14 13 12 11 24 23 22 21 Selection and Specifications Industrial Pressure Switches XML Electromechanical Pressure Switches Table 50: Size 160 bar (2320 psi) Fixed differential, for detection of a single threshold Switches with 1 C/O single-pole contact Pressure connection 1/2" NPT or 1/4" BSP Pressure Switches, Type XMLA With setting scale Without setting scale Adjustable Range of Operating Point (PH) 10–160 bar (145–2320 psi) (Rising pressure) Electrical Connection Terminals DIN connector Terminals DIN connector (1) Catalog Numbers Hydraulic oils, up to 320 °F XMLA160D2S13 XMLA160D2C11 XMLA160D1S13 XMLA160D1C11 (160 °C) Fluids Controlled Fresh water, sea water, up to XMLA160E2S13 XMLA160E2C11 XMLA160E1S13 XMLA160E1C11 320 °F (160 °C) (2) Corrosive fluids, air, up to XMLA160N2S13 XMLA160N2C11 XMLA160N1S13 XMLA160N1C11 320 °F (160 °C) Weight, lb (kg) 1.65 (0.750) 1.72 (0.780) 1.65 (0.750) 1.72 (0.780) Supplementary Specifications (not shown under general specifications) At low setting 5.5 bar (79.75 psi), ±1 bar (±14.5 psi) Inherent Differential (subtract from PH to get PB) At high setting 18 bar (261 psi), ±3 bar (±43.5 psi) Per cycle 200 bar (2900 psi) Maximum Allowable Pressure Accidental 360 bar (5220 psi) Destruction Pressure 720 bar (10,440 psi) 6 Mechanical life 6 x 10 operating cycles Cable Entry and Wire Size for Terminal Models 1/2" NPT, 1 x 0.2 mm² minimum, 2 x 2.5 mm² maximum. Connector Type for Connector Models DIN 43650A, 4-pin male. For suitable female connector, see page 73. Pressure Switch Style Piston (1) For 1 entry tapped for PG 13.5 conduit/cable entry, replace S13 with S11 (example: XMLA160D2S13 becomes XMLA160D2S11). (2) Component materials of units in contact with the fluid, see pages 77–78. Operating Curves Connection Terminal model bar Pressure PH 160 140 PB 120 Connector model 100 Pressure switch connector pin view 80 60 1 →11 and 13 Time 2 →12 40 1 2 3 3 →14 20 10 –– Adjustable value 0 4.5 20 40 60 80 100 120 142 160 bar --- Non adjustable value Falling pressure Other Versions For switches with alternative tapped cable entries (such as NPT), consult your local sales office. 61 © 1998–2009 Schneider Electric 10/2009 All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Rising pressure 14 13 12 11 Selection and Specifications Industrial Pressure Switches XML Electromechanical Pressure Switches Table 51: Size 160 bar (2320 psi) Adjustable differential, for regulation between two thresholds Switches with 1 C/O single-pole contact Pressure connection 1/2" NPT or 1/4" BSP Pressure Switches, Type XMLB With setting scale Without setting scale Adjustable Range of Operating Point (PH) 10–160 bar (145–2320 psi) (Rising pressure) Electrical Connection Terminals DIN connector Terminals DIN connector (1) Catalog Numbers Hydraulic oils, up to 320 °F XMLB160D2S13 XMLB160D2C11 XMLB160D1S13 XMLB160D1C11 (160 °C) Fluids Controlled Fresh water, sea water, up to XMLB160E2S13 XMLB160E2C11 XMLB160E1S13 XMLB160E1C11 320 °F (160 °C) (2) Corrosive fluids, air, up to XMLB160N2S13 XMLB160N2C11 XMLB160N1S13 XMLB160N1C11 320 °F (160 °C) Weight, lb (kg) 1.65 (0.750) 1.72 (0.780) 1.65 (0.750) 1.72 (0.780) Supplementary Specifications (not shown under general specifications) Min. at low setting 9.3 bar (134.85 psi), –1.8 bar, +1.5 bar (–26.1 psi, +21.75 psi) Possible Differential Min. at high setting 20.8 bar (301.6 psi), –1.9 bar, +1.6 bar (–27.55 psi, +23.2 psi) (subtract from PH to get PB) Max. at high setting 100 bar (1450 psi) Per cycle 200 bar (2900 psi) Maximum Allowable Pressure Accidental 360 bar (5220 psi) Destruction Pressure 720 bar (10,440 psi) Cable Entry and Wire Size for Terminal Models 1/2" NPT, 1 x 0.2 mm² minimum, 2 x 2.5 mm² maximum. Connector Type for Connector Models DIN 43650A, 4-pin male. For suitable female connector, see page 73. Pressure Switch Style Piston (1) For 1 entry tapped for PG 13.5 conduit/cable entry, replace S13 with S11 (example: XMLB160D2S13 becomes XMLB160D2S11). (2) Component materials of units in contact with the fluid, see pages 77–78. Operating Curves Connection 1 Maximum Terminal model bar Pressure 160 differential 2 Minimum PH differential 120 1 PB Connector model 2 Pressure switch connector pin view 80 1 →11 and 13 2 →12 Time 40 1 2 3 →14 –– Adjustable value 3 10 0 0.7 40 60 80 120 139.2 bar Falling pressure Other Versions For switches with alternative tapped cable entries (such as NPT), consult your local sales office. 62 10/2009 © 1998–2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Rising pressure 14 13 12 11 Selection and Specifications Industrial Pressure Switches XML Electromechanical Pressure Switches Table 52: Size 160 bar (2320 psi) Adjustable differential, for regulation between two thresholds Switches with 2 C/O single-pole contacts Pressure connection 1/2" NPT or 1/4" BSP Pressure Switches, Type XMLC With setting scale Adjustable Range of Operating Point (PH) 12–160 bar (174–2320 psi) (Rising pressure) Electrical Connection Terminals (1) Catalog Numbers Hydraulic oils, up to 320 °F XMLC160D2S13 (160 °C) Fluids Controlled Fresh water, sea water, XMLC160E2S13 up to 320 °F (160 °C) (2) Corrosive fluids, up to 320 °F XMLC160N2S13 (160 °C) Weight, lb (kg) 1.65 (0.750) Supplementary Specifications (not shown under general specifications) Min. at low setting 9 bar (130.5 psi), ±0.9 bar (±13.05 psi) Possible Differential Min. at high setting 21 bar (304.5 psi), ±0.9 bar (±13.05 psi) (subtract from PH to get PB) Max. at high setting 110 bar (1590 psi) Per cycle 200 bar (2900 psi) Maximum Allowable Pressure Accidental 360 bar (5220 psi) Destruction Pressure 720 bar (10,440 psi) 6 Mechanical life 6 x 10 operating cycles 1/2" NPT, 1 x 0.2 mm² minimum, 2 x 2.5 mm² maximum. Cable Entry and Wire Size for Terminal Models Pressure Switch Style Piston (1) For 1 entry tapped for PG 13.5 conduit/cable entry, replace S13 with S11 (example: XMLC160D2S13 becomes XMLC160D2S11). (2) Component materials of units in contact with the fluid, see pages 77–78. Operating Curves Connection 1 Maximum bar Pressure Terminal model 160 differential PH 2 Minimum 1 differential 2 100 PB 50 Time –– Adjustable value 12 0 3 50 100 139 bar Falling pressure Other Versions For switches with alternative tapped cable entries (such as NPT), consult your local sales office. 63 © 1998–2009 Schneider Electric 10/2009 All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Rising pressure 14 13 12 11 24 23 22 21 Selection and Specifications Industrial Pressure Switches XML Electromechanical Pressure Switches Table 53: Size 160 bar (2320 psi) Dual-stage, fixed differential, for detection at each threshold Switches with 2 C/O single-pole contacts (one per stage) Pressure connection 1/2" NPT or 1/4" BSP Pressure Switches, Type XMLD Without setting scale 2nd stage operating point (PH2) 16.5–160 bar (239.25–2320 psi) Adjustable Range of Each Operating Point 1st stage operating point (PH1) 10.5–154 bar (152.25–2233 psi) (Rising pressure) Spread between the Two Stages (PH2–PH1) 6–83 bar (87–1203.5 psi) Electrical Connection Terminals (1) Catalog Numbers Hydraulic oils, up to 320 °F (160 °C) XMLD160D1S13 Fresh water, sea water, up to 320 °F Fluids Controlled XMLD160E1S13 (160 °C) (2) Corrosive fluids, air, up to 320 °F XMLD160N1S13 (160 °C) Weight, lb (kg) 1.65 (0.750) Supplementary Specifications (not shown under general specifications) Inherent Differential At low setting 8.8 bar (127.6 psi), ±1.5 bar (±21.75 psi) (subtract from PH1/PH2 At high setting 20 bar (290 psi), ±7 bar (±101.5 psi) to get PB1/PB2) Per cycle 200 bar (2900 psi) Maximum Allowable Pressure Accidental 360 bar (5220 psi) Destruction Pressure 720 bar (10,440 psi) Cable Entry and Wire Size for Terminal Models 1/2" NPT, 1 x 0.2 mm² minimum, 2 x 2.5 mm² maximum. Pressure Switch Style Piston (1) For 1 entry tapped for PG 13.5 conduit/cable entry, replace S13 with S11 (example: XMLD160D1S13 becomes XMLD160D1S11). (2) Component materials of units in contact with the fluid, see pages 77–78. Operating Curves High setting trip points of contacts 1 and 2 Inherent differential of contacts 1 and 2 bar Pressure bar H 160 154 PH2 F 140 PB2 120 120 1 PH1 100 PB1 94.5 2 80 80 60 Time 40 40 –– Adjustable value G 16.5 16.5 --- Non adjustable value 10.5 10 E 0 0 Connection 1.7 7.7 40 60 80 100 134140 160bar 0 10.5 40 60 77 100 120 154bar Falling pressure Terminal model PH1 setting (rising pressure) EF Contact 1 (stage 1) 1 Maximum differential Contact 2 (stage 2) Contact 1 (stage 1) GH Contact 2 (stage 2) 2 Minimum differential For switches with alternative tapped cable entries (such as NPT), Other Versions consult your local sales office. 64 10/2009 © 1998–2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com PH2 setting (rising pressure) Rising pressure 14 13 12 11 24 23 22 21 Selection and Specifications Industrial Pressure Switches XML Electromechanical Pressure Switches Table 54: Size 300 bar (4350 psi) Fixed differential, for detection of a single threshold Switches with 1 C/O single-pole contact Pressure connection 1/2" NPT or 1/4" BSP Pressure Switches, Type XMLA With setting scale Without setting scale Adjustable Range of Operating Point (PH) 20–300 bar (290–4350 psi) (Rising pressure) Electrical Connection Terminals DIN connector Terminals DIN connector (1) Catalog Numbers Hydraulic oils, up to 320 °F XMLA300D2S13 XMLA300D2C11 XMLA300D1S13 XMLA300D1C11 (160 °C) Fluids Controlled Fresh water, sea water, up to XMLA300E2S13 XMLA300E2C11 XMLA300E1S13 XMLA300E1C11 320 °F (160 °C) (2) (3) Corrosive fluids, air, up to XMLA300N2S13 XMLA300N2C11 XMLA300N1S13 XMLA300N1C11 320 °F (160 °C) Weight, lb (kg) 1.65 (0.750) 1.72 (0.780) 1.65 (0.750) 1.72 (0.780) Supplementary Specifications (not shown under general specifications) At low setting 16.5 bar (239.25 psi), ±3 bar (±43.5 psi) Inherent Differential (subtract from PH to get PB) At high setting 35 bar (507.5 psi), ±6 bar (±87 psi) Per cycle 375 bar (5437.5 psi) Maximum Allowable Pressure Accidental 675 bar (9787.5 psi) Destruction Pressure 1350 bar (19,575 psi) Cable Entry and Wire Size for Terminal Models 1/2" NPT, 1 x 0.2 mm² minimum, 2 x 2.5 mm² maximum. Connector Type for Connector Models DIN 43650A, 4-pin male. For suitable female connector, see page 73. Pressure Switch Style Piston (1) For 1 entry tapped for PG 13.5 conduit/cable entry, replace S13 with S11 (example: XMLA300D2S13 becomes XMLA300D2S11). (2) Component materials of units in contact with the fluid, see pages 77–78. (3) Only for control of group 2 fluids, in accordance with directive 97/23/EEC. Operating Curves Connection Terminal model bar Pressure PH 300 PB 200 Connector model Pressure switch connector pin view 100 Time 1 →11 and 13 –– Adjustable value 1 2 2 →12 --- Non adjustable value 3 20 3 →14 0 3.5 100 200 265 300 bar Falling pressure Other Versions For switches with alternative tapped cable entries (such as NPT), consult your local sales office. 65 © 1998–2009 Schneider Electric 10/2009 All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Rising pressure 14 13 12 11 Selection and Specifications Industrial Pressure Switches XML Electromechanical Pressure Switches Table 55: Size 300 bar (4350 psi) Adjustable differential, for regulation between two thresholds Switches with 1 C/O single-pole contact Pressure connection 1/2" NPT or 1/4" BSP Pressure Switches, Type XMLB With setting scale Without setting scale Adjustable Range of Operating Point (PH) 22–300 bar (319–4350 psi) (Rising pressure) Electrical Connection Terminals DIN connector Terminals DIN connector (1) Catalog Numbers Hydraulic oils, up to 320 °F XMLB300D2S13 XMLB300D2C11 XMLB300D1S13 XMLB300D1C11 (160 °C) Fluids Controlled Fresh water, sea water, up to XMLB300E2S13 XMLB300E2C11 XMLB300E1S13 XMLB300E1C11 320 °F (160 °C) (2) (3) Corrosive fluids, air, up to 320 °F XMLB300N2S13 XMLB300N2C11 XMLB300N1S13 XMLB300N1C11 (160 °C) Weight, lb (kg) 1.65 (0.750) 1.72 (0.780) 1.65 (0.750) 1.72 (0.780) Supplementary Specifications (not shown under general specifications) Min. at low setting 19.4 bar (281.3 psi), –1.5 bar, +1.7 bar (–21.75 psi, +24.65 psi) Possible Differential Min. at high setting 37 bar (536.5 psi), –1 bar, +4 bar (–14.5 psi, +58 psi) (subtract from PH to get PB) Max. at high setting 200 bar (2900 psi) Per cycle 375 bar (5437.5 psi) Maximum Allowable Pressure Accidental 675 bar (9787.5 psi) Destruction Pressure 1350 bar (19,575 psi) Cable Entry and Wire Size for Terminal Models 1/2" NPT, 1 x 0.2 mm² minimum, 2 x 2.5 mm² maximum. Connector Type for Connector Models DIN 43650A, 4-pin male. For suitable female connector, see page 73. Pressure Switch Style Piston (1) For 1 entry tapped for PG 13.5 conduit/cable entry, replace S13 with S11 (example: XMLB300D2S13 becomes XMLB300D2S11). (2) Component materials of units in contact with the fluid, see pages 77–78. (3) Only for control of group 2 fluids, in accordance with directive 97/23/EEC. Operating Curves Connection 1 Maximum Terminal model bar Pressure 300 differential PH 2 Minimum differential 200 1 PB Connector model 2 Pressure switch connector pin view 100 1 →11 and 13 Time 2 →12 –– Adjustable value 1 2 3 →14 22 3 0 2.6 100 200 263 bar Falling pressure Other Versions For switches with alternative tapped cable entries (such as NPT), consult your local sales office. 66 10/2009 © 1998–2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Rising pressure 14 13 12 11 Selection and Specifications Industrial Pressure Switches XML Electromechanical Pressure Switches Table 56: Size 300 bar (4350 psi) Adjustable differential, for regulation between two thresholds Switches with 2 C/O single-pole contacts Pressure connection 1/2" NPT or 1/4" BSP Pressure Switches, Type XMLC With setting scale Adjustable Range of Operating Point (PH) 22–300 bar (319–4350 psi) (Rising pressure) Electrical Connection Terminals (1) Catalog Numbers Hydraulic oils, up to 320 °F XMLC300D2S13 (160 °C) Fluids Controlled Fresh water, sea water, up to XMLC300E2S13 320 °F (160 °C) (2) (3) Corrosive fluids, air, up to XMLC300N2S13 320 °F (160 °C) Weight, lb (kg) 1.65 (0.750) Supplementary Specifications (not shown under general specifications) Min. at low setting 16 bar (232 psi), ±0.9 bar (±13.05 psi) Possible Differential Min. at high setting 35 bar (507.5 psi), ±0.9 bar (±13.05 psi) (subtract from PH to get PB) Max. at high setting 240 bar (3480 psi) Per cycle 375 bar (5437.5 psi) Maximum Allowable Pressure Accidental 675 bar (9787.5 psi) Destruction Pressure 1350 bar (19,575 psi) 6 Mechanical life 3 x 10 operating cycles Cable Entry and Wire Size for Terminal Models 1/2" NPT, 1 x 0.2 mm² minimum, 2 x 2.5 mm² maximum. Pressure Switch Style Piston (1) For 1 entry tapped for PG 13.5 conduit/cable entry, replace S13 with S11 (example: XMLC300D2S13 becomes XMLC300D2S11). (2) Component materials of units in contact with the fluid, see pages 77–78. (3) Only for control of group 2 fluids, in accordance with directive 97/23/EEC. Operating Curves Connection 1 Maximum Terminal model bar Pressure 300 differential PH 2 Minimum 1 differential 200 PB 2 100 Time –– Adjustable value 22 0 6 60 100 200 265 bar Falling pressure Other Versions For switches with alternative tapped cable entries (such as NPT), consult your local sales office. 67 © 1998–2009 Schneider Electric 10/2009 All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Rising pressure 14 13 12 11 24 23 22 21 Selection and Specifications Industrial Pressure Switches XML Electromechanical Pressure Switches Table 57: Size 300 bar (4350 psi) Dual-stage, fixed differential, for detection at each threshold Switches with 2 C/O single-pole contacts (one per stage) Pressure connection 1/2" NPT or 1/4" BSP Pressure Switches, Type XMLD Without setting scale Adjustable Range of 2nd stage operating point (PH2) 36–300 bar (522–4350 psi) Each Operating Point 1st stage operating point (PH1) 25–289 bar (362.5–4190.5 psi) (Rising pressure) Spread between the Two Stages (PH2–PH1) 11–189 bar (159.5–2740.5 psi) Electrical Connection Terminals (1) Catalog Numbers Hydraulic oils, up to 320 °F (160 °C) XMLD300D1S13 Fresh water, sea water, up to 320 °F Fluids Controlled XMLD300E1S13 (160 °C) (2) (3) Corrosive fluids, air, up to 320 °F XMLD300N1S13 (160 °C) 1.65 (0.750) Weight, lb (kg) Supplementary Specifications (not shown under general specifications) Inherent Differential At low setting 17 bar (246.5 psi), ±2.5 bar (±36.25 psi) (subtract from PH1/PH2 At high setting 42 bar (609 psi), ±9 bar (±130.5 psi) to get PB1/PB2) Per cycle 375 bar (5437.5 psi) Maximum Allowable Pressure Accidental 675 bar (9787.5 psi) Destruction Pressure 1350 bar (19,575 psi) Cable Entry and Wire Size for Terminal Models 1/2" NPT, 1 x 0.2 mm² minimum, 2 x 2.5 mm² maximum. (1) For 1 entry tapped for PG 13.5 conduit/cable entry, replace S13 with S11 (example: XMLD300D1S13 becomes XMLD300D1S11). (2) Component materials of units in contact with the fluid, see pages 77–78. (3) Only for control of group 2 fluids, in accordance with directive 97/23/EEC. Operating Curves Pressure Switch Style Piston bar bar Pressure H 300 300 289 PH2 F PB2 1 215 PH1 200 200 PB1 2 100 100 Time 36 –– Adjustable value G 36 20 --- Non adjustable value 25 E 0 0 Connection 025 111 200 289bar 258 bar 819 100 200 247 300 PH1 setting (rising pressure) Falling pressure Terminal model 1 Maximum differential EF Contact 1 (stage 1) 2 Minimum differential Contact 2 (stage 2) Contact 1 (stage 1) GH Contact 2 (stage 2) For switches with alternative tapped cable entries (such as NPT), Other Versions consult your local sales office. 68 10/2009 © 1998–2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com PH2 setting (rising pressure) Rising pressure 14 13 12 11 24 23 22 21 Selection and Specifications Industrial Pressure Switches XML Electromechanical Pressure Switches Table 58: Size 500 bar (7250 psi) Fixed differential, for detection of a single threshold Switches with 1 C/O single-pole contact Pressure connection 1/2" NPT or 1/4" BSP Pressure Switches, Type XMLA With setting scale Without setting scale Adjustable Range of Operating Point (PH) 30–500 bar (435–7250 psi) (Rising pressure) Electrical Connection Terminals DIN connector Terminals DIN connector (1) Catalog Numbers Hydraulic oils, up to 320 °F XMLA500D2S13 XMLA500D2C11 XMLA500D1S13 XMLA500D1C11 (160 °C) Fluids Controlled Fresh water, sea water, up to XMLA500E2S13 XMLA500E2C11 XMLA500E1S13 XMLA500E1C11 320 °F (160 °C) (2) (3) Corrosive fluids, air, up to XMLA500N2S13 XMLA500N2C11 XMLA500N1S13 XMLA500N1C11 320 °F (160 °C) Weight, lb (kg) 1.65 (0.750) 1.72 (0.780) 1.65 (0.750) 1.72 (0.780) Supplementary Specifications (not shown under general specifications) At low setting 20 bar (290 psi), ±6 bar (±87 psi) Inherent Differential (subtract from PH to get PB) At high setting 45 bar (652.5 psi), ±10 bar (±145 psi) Per cycle 625 bar (9062.5 psi) Maximum Allowable Pressure Accidental 1125 bar (16,312.5 psi) Destruction Pressure 2250 bar (32,625 psi) 6 Mechanical life 3 x 10 operating cycles Cable Entry and Wire Size for Terminal Models 1/2" NPT, 1 x 0.2 mm² minimum, 2 x 2.5 mm² maximum. Connector Type for Connector Models DIN 43650A, 4-pin male. For suitable female connector, see page 73. Pressure Switch Style Piston (1) For 1 entry tapped for PG 13.5 conduit/cable entry, replace S13 with S11 (example: XMLA500D2S13 becomes XMLA500D2S11). (2) Component materials of units in contact with the fluid, see pages 77–78. (3) Only for control of group 2 fluids, in accordance with directive 97/23/EEC. Operating Curves Terminal model bar Pressure 500 PH 400 PB 300 Connector model 200 Pressure switch connector pin view Time 1 →11 and 13 100 –– Adjustable value 2 →12 1 2 --- Non adjustable value 30 3 3 →14 0 10 100 200 300 400 455 bar Falling pressure For switches with alternative tapped cable entries (such as NPT), consult your local sales office. Other Versions 69 © 1998–2009 Schneider Electric 10/2009 All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Rising pressure 14 13 12 11 Selection and Specifications Industrial Pressure Switches XML Electromechanical Pressure Switches Table 59: Size 500 bar (7250 psi) Adjustable differential, for regulation between two thresholds Switches with 1 C/O single-pole contact Pressure connection 1/2" NPT or 1/4" BSP Pressure Switches, Type XMLB With setting scale Without setting scale Adjustable Range of Operating Point (PH) 30–500 bar (435–7250 psi) (Rising pressure) Electrical Connection Terminals DIN connector Terminals DIN connector (1) Catalog Numbers Hydraulic oils, up to 320 °F XMLB500D2S13 XMLB500D2C11 XMLB500D1S13 XMLB500D1C11 (160 °C) Fluids Controlled Fresh water, sea water, up to XMLB500E2S13 XMLB500E2C11 XMLB500E1S13 XMLB500E1C11 320 °F (160 °C) (2) (3) Corrosive fluids, air, up to XMLB500N2S13 XMLB500N2C11 XMLB500N1S13 XMLB500N1C11 320 °F (160 °C) Weight, lb (kg) 1.65 (0.750) 1.72 (0.780) 1.65 (0.750) 1.72 (0.780) Supplementary Specifications (not shown under general specifications) Min. at low setting 23 bar (333.5 psi), –2.6 bar, +3.8 bar (–37.7 psi, +55.1 psi) Possible Differential Min. at high setting 52.6 bar (762.7 psi), –14.8 bar, +11.2 bar (–214.6 psi, +162.4 psi) (subtract from PH to get PB) Max. at high setting 300 bar (4350 psi) Per cycle 625 bar (9062.5 psi) Maximum Allowable Pressure Accidental 1125 bar (16,312.5 psi) Destruction Pressure 2250 bar (32,625 psi) Cable Entry and Wire Size for Terminal Models 1/2" NPT, 1 x 0.2 mm² minimum, 2 x 2.5 mm² maximum. Connector Type for Connector Models DIN 43650A, 4-pin male. For suitable female connector, see page 73. Pressure Switch Style Piston (1) For 1 entry tapped for PG 13.5 conduit/cable entry, replace S13 with S11 (example: XMLB500D2S13 becomes XMLB500D2S11). (2) Component materials of units in contact with the fluid, see pages 77–78. (3) Only for control of group 2 fluids, in accordance with directive 97/23/EEC. Operating Curves Connection 1 Maximum Terminal model bar Pressure 500 differential PH 2 Minimum differential 400 PB 300 1 Connector model 2 200 Pressure switch connector pin view 1 →11 and 13 Time 100 2 →12 –– Adjustable value 1 2 3 →14 30 3 0 7 100 200 400 447.4 bar Falling pressure Other Versions For switches with alternative tapped cable entries (such as NPT), consult your local sales office. 70 10/2009 © 1998–2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Rising pressure 14 13 12 11 Selection and Specifications Industrial Pressure Switches XML Electromechanical Pressure Switches Table 60: Size 500 bar (7250 psi) Adjustable differential, for regulation between 2 thresholds Switches with 2 C/O single-pole contacts Pressure connection 1/2" NPT or 1/4" BSP Pressure Switches, Type XMLC With setting scale Adjustable Range of Operating Point (PH) 30–500 bar (435–7250 psi) (Rising pressure) Electrical Connection Terminals (1) Catalog Numbers Hydraulic oils, up to 320 °F XMLC500D2S13 (160 °C) Fluids Controlled Fresh water, sea water, up to XMLC500E2S13 320 °F (160 °C) (2) (3) Corrosive fluids, air, up to XMLC500N2S13 320 °F (160 °C) Weight, lb (kg) 1.65 (0.750) Supplementary Specifications (not shown under general specifications) Min. at low setting 19 bar (275.5 psi), ±0.9 bar (±13.05 psi) Possible Differential Min. at high setting 52 bar (754 psi), ±0.9 bar (±13.05 psi) (subtract from PH to get PB) Max. at high setting 340 bar (4930 psi) Per cycle 625 bar (9062.5 psi) Maximum Allowable Pressure Accidental 1125 bar (16,312.5 psi) Destruction Pressure 2250 bar (32,625 psi) Cable Entry and Wire Size for Terminal Models 1/2" NPT, 1 x 0.2 mm² minimum, 2 x 2.5 mm² maximum. Pressure Switch Style Piston (1) For 1 entry tapped for PG 13.5 conduit/cable entry, replace S13 with S11 (example: XMLC500D2S13 becomes XMLC500D2S11). (2) Component materials of units in contact with the fluid, see pages 77–78. (3) Only for control of group 2 fluids, in accordance with directive 97/23/EEC. Operating Curves Connection 1 Maximum Terminal model Pressure bar 500 differential PH 2 Minimum differential 400 1 PB 300 2 200 Time 100 –– Adjustable value 30 0 160 200 bar 11 100 300 400 448 Falling pressure Other Versions For switches with alternative tapped cable entries (such as NPT), consult your local sales office. 71 © 1998–2009 Schneider Electric 10/2009 All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Rising pressure 14 13 12 11 24 23 22 21 Selection and Specifications Industrial Pressure Switches XML Electromechanical Pressure Switches Table 61: Size 500 bar (7250 psi) Dual-stage, fixed differential, for detection at each threshold Switches with 2 C/O single-pole contacts (one per stage) Pressure connection 1/2" NPT or 1/4" BSP Pressure Switches, Type XMLD Without setting scale 2nd stage operating point (PH2) 41–500 bar (594.5–7250 psi) Adjustable Range of Each Operating Point (Rising pressure) 1st stage operating point (PH1) 25–484 bar (362.5–7018 psi) Spread between the Two Stages (PH2–PH1) 16–244 bar (232–3538 psi) Electrical Connection Terminals (1) Catalog Numbers Hydraulic oils, up to 320 °F (160 °C) XMLD500D1S13 Fresh water, sea water, up to 320 °F Fluids Controlled XMLD500E1S13 (160 °C) (2) (3) Corrosive fluids, air, up to 320 °F XMLD500N1S13 (160 °C) Weight, lb (kg) 1.65 (0.750) Supplementary Specifications (not shown under general specifications) Inherent Differential At low setting 21 bar (304.5 psi), ±3 bar (±43.5 psi) (subtract from PH1/PH2 At high setting 65 bar (942.5 psi), ±10 bar (±145 psi) to get PB1/PB2) Per cycle 625 bar (9062.5 psi) Maximum Allowable Pressure Accidental 1125 bar (16,312.5 psi) Destruction Pressure 2250 bar (32,625 psi) Cable Entry and Wire Size for Terminal Models 1/2" NPT, 1 x 0.2 mm² minimum, 2 x 2.5 mm² maximum. Pressure Switch Style Piston (1) For 1 entry tapped for PG 13.5 conduit/cable entry, replace S13 with S11 (example: XMLD500D1S13 becomes XMLD500D1S11). (2) Component materials of units in contact with the fluid, see pages 77–78. (3) Only for control of group 2 fluids, in accordance with directive 97/23/EEC. Operating Curves High setting trip points of contacts 1 and 2 Inherent differential of contacts 1 and 2 bar bar Pressure H 500 484 F PH2 PB2 400 400 PH1 1 PB1 300 300 273.5 2 200 200 Time 100 100 –– Adjustable value G 41 41 --- Non adjustable value 25 E 0 0 Connection 25 100 200 256 300 400 484bar 420 100 200 300 419 435 bar PH1 setting (rising pressure) Falling pressure Terminal model bh EF Contact 1 (stage 1) 1 Maximum differential Contact 2 Contact 1 GH Contact 2 (stage 2) 2 Minimum differential (stage 2) (stage 1) For switches with alternative tapped cable entries (such as NPT), consult your local Other Versions sales office. 72 10/2009 © 1998–2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com PH2 setting (rising pressure) Rising pressure 14 13 12 11 24 23 22 21 Selection and Specifications Industrial Pressure Switches XML Electromechanical Pressure Switches Table 62: Accessories for Pressure Switches and Vacuum Switches Specific For use with Weight Description Catalog number characteristics switches lb (kg) Rear fixing bracket XML•L35 — XMLZL006 0.51 (0.230) for vibrations > 2 gn XML•001 XMLAM01 Additional top support bracket XML•M05 — XMLZL002 0.04 (0.020) for vibrations > 4 gn XMLA004 XML•010 to XML•500 Knurled adjustment knob, Ø 36 mm fits over adjustment screw(s) to facilitate — All models XMLZL003 0.022 (0.010) setting XMLAM01 Fixing plate XML•M05 for replacing an XMJA or XMGB switch — XMLZL004 0.024 (0.110) XMLA004 by an XML switch XML•010 to XML•500 Lead sealable protective cover XMLA to prevent unauthorized access to adjustment — XMLZL001 0.08 (0.035) XMLB screws and fixing screw of switch cover Lead sealable protective cover to deter unauthorized access to the adjustment — All models XMLZL011 0.07 (0.030) screws 24/48 Vac/Vdc XMLA/B XMLZZ024 0.20 (0.090) Without setting scale 110/240 Vac XMLA/B XMLZZ120 0.20 (0.090) Indicator modules and XMLA XMLZA024 0.20 (0.090) associated covers, 2 LEDs 24/48 Vac/Vdc XMLB XMLZB024 0.20 (0.090) (orange and green) With setting scale XMLA XMLZA120 0.20 (0.090) 110/240 Vac XMLB XMLZB120 0.20 (0.090) Hydraulic block — All models XMLZL005 0.53 (0.240) for base mounting directly onto fluid manifold Female connector, DIN 43650A — XML••••••C11 XZCC43FCP40B 0.08 (0.035) Jumper cables, DIN 43650 A - M12, L = 1 m XML••••••C11 XZCR1523062K1 0.18 (0.080) straight, male for splitter boxes L = 2 m XML••••••C11 XZCR1523062K2 0.024 (0.110) (for connections, see catalog 9014CT0201) Adapter, G 1/4" – G 3/8" male/female — All models XMLZL012 0.29 (0.130) Table 63: Renewal Parts Specific For use with Weight Description Catalog number characteristics switches lb (kg) Sealing gasket For sizes u 300 bar XMLA/B/C/D XMLZL010 0.03 (0.015) XML•S35 XMLZL013 0.13 (0.060) Diaphragms — XML•S02 XMLZL014 0.09 (0.040) XML•S04 XMLZL015 0.07 (0.030) XZCC43FCP40B Connector Pinout 3 3 12 12 73 © 1998–2009 Schneider Electric 10/2009 All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Dimensions Industrial Pressure Switches XML Electromechanical Pressure Switches XML•L35, XML•001, XML•S XMLC/D: 46 (1.81) Dim.: mm (in.) a XMLA/B: 35 (1.38) (2) (1) (0.26) = 45 = 57 (1.77) 2.24 (1) (2) 1 fluid entry, tapped G 1/4 (BSP female) 1 electrical connections entry, tapped M20 x 1.5, Pg 13.5, or 1/2" NTP XMLBM03, XMLBL05 40 (1.57) (3) (4) (2) 0.20 (1) 20 20 c2 (0.79) (0.79) c1 Øa XML Øa c1 c2 BM03 150 (5.91) 155.5 (6.12) 80.5 (3.17) (1) 1 fluid entry, tapped G 1/4 (BSP female) (2) BL05 200 (7.87) 204 (8.03) 104 (4.09) 1 electrical connections entry, tapped M20 x 1.5, Pg 13.5, or 1/2" NTP (3) 2 elongated holes Ø 10.2 x 5.2 (0.40 x 0.20) •L35, •001 110 (4.33) — — (4) 1 elongated hole Ø 15.2 x 5.2 (0.60 x 0.20) •S35, •S02, •S04 110 (4.33) — — •S10, •S20 86 (3.39) — — 74 10/2009 © 1998–2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 145 (5.71) 56.5 (2.22) 17 (0.67) 10 (0.39) max: 162 (6.38) 56 65 (2.20) (2.56) Dimensions Industrial Pressure Switches XML Electromechanical Pressure Switches XMLAM01, XMLBM05, XMLCM05, XMLA004, XML•010 to 500 XMLC/D: 85 (3.35) XMLC/D: 46 (1.81) XMLA/B: 75 (2.95) XMLA/B: 35 (1.38) 5 (0.197) (2) 37 (1.46) (0.205) 20–22 (1) == 23 (0.79–0.87) (0.91) 56 (2.20) 120 (4.72) (1) 1 fluid entry, tapped G 1/4 (BSP female) Ø: 2 elongated holes, Ø 5.2 x 6.7 (2) 1 electrical connections entry, tapped M20 x 1.5, Pg 13.5, or 1/2" NTP XML•M02, XML•002, XMLB004, XMLC004, XMLD004 55 (2.17) XMLC/D: 46 (1.81) XMLC/D: 90 (3.54) XMLA/B: 35 (1.38) XMLA/B: 77.5 (3.05) Ø5.2 (0.20) (2) Ø (1) 30 == 37–40 (1.18) 122 (1.46–1.57) (4.80) (1) 1 fluid entry, tapped G 1/4 (BSP female) Ø: 2 elongated holes, Ø 10.2 x 5.2 (2) 1 electrical connections entry, tapped M20 x 1.5, Pg 13.5, or 1/2" NTP 75 © 1998–2009 Schneider Electric 10/2009 All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 37 (1.46) 158 (6.22) 34 106 13 (1.34) (4.17) (0.51) 113 (4.45) 17.5 (0.69) Dimensions Industrial Pressure Switches XML Electromechanical Pressure Switches XMLBL35P, XMLB001P (4.33) (2) 55 (1) (2.17) (1.97) (1) (2) 1 fluid entry, tapped G 1¼ (BSP female) 1 electrical connections entry, tapped M20 x 1.5, Pg 13.5, or 1/2" NTP XMLBM05P, XMLA004P, XML•010P, XML•020P, XML•035P 35 (1.38) 5 (0.197) 37 (1.46) (0.205) (2) (1) 25 (0.98) (1.97) 76 (2.99) (1) (2) 1 fluid entry, tapped G 1¼ (BSP female) 1 electrical connections entry, tapped M20 x 1.5, Pg 13.5, or 1/2" NTP 76 10/2009 © 1998–2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 54 (2.13) 86.5 (3.41) 130 (5.12) 175 (6.89) Materials in Contact with Fluid Industrial Pressure Switches XML Electromechanical Pressure Switches Table 64: Component Materials in Contact with Fluid Zinc Stainless FPM, Pressure or vacuum switch catalog number Brass Steel Nitrile PTFE Aluminium alloy steel FKM (1) XMLAM01V••••, XML•M02V•••• (2) XMLAM01T••••, XML•M02T•••• XMLBM03R•••• (3) XMLBM03S•••• (1) XML•M05A•••• (1) XML•M05B•••• XML•M05C•••• (1) XMLBM05••••• (1) XMLBL05R•••• XMLBL05S•••• (3) XML•L35R••••, XML•S35R•••• (1) XML•L35S•••• (3) XMLBL35P•••• (1) XML•001R•••• (1) XML•001S•••• (3) XMLB001P•••• (1) XML•002A•••• XML•002B••••, XML•S02B•••• XML•002C•••• (3) XMLA004A•••• XMLA004B•••• XMLA004C•••• (2) XMLA004P•••• Materials in contact with fluid (1) 1.4307 (AISI 316L) (2) 1.4404 (AISI 316L) (3) 1.4305 (AISI 303) 77 © 1998–2009 Schneider Electric 10/2009 All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Materials in Contact with Fluid Industrial Pressure Switches XML Electromechanical Pressure Switches Table 65: Component Materials in Contact with Fluid (continued) Zinc Stainless FPM, Pressure switch catalog number Brass Steel Nitrile PTFE Aluminium alloy steel FKM XMLB004A•••• XML•004B••••, XML•S04B•••• (3) XML•004C•••• XML•010A•••• XML•010B•••• (2) XML•010C•••• XML•010P••••, XML•S10A•••• XML•020A••••, XML•035A•••• XML•020B••••, XML•035B•••• XML•020C••••, XML•035C•••• (2) XML•020P••••, XML•035P••••, XML•S20A•••• XML•070D••••, XML•160D•••• XML•070E••••, XML•160E•••• (4) XML•070N••••, XML•160N•••• (5) XML•300D•••• XML•300E•••• (4) XML•300N•••• (5) XML•500D•••• XML•500E•••• XML•500N••••4 (5) Materials in contact with fluid (1) 1.4307 (AISI 316L) (2) 1.4404 (AISI 316L) (3) 1.4305 (AISI 303) (4) 1.4404 (AISI 316L) + 1.4462 (5) 1.4404 (AISI 316L) + 1.4305 (AISI 303) 78 10/2009 © 1998–2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Introduction Industrial Pressure Switches 9012G Pressure Switches 9012G Pressure Switches The 9012G pressure switches are UL Listed and CSA Certified as industrial control equipment. They are used to interface pneumatic or hydraulic systems with electrical control systems by opening or closing electrical contacts in response to pressure changes in the system. They have outstanding repeatability and drift performance. Their efficient design uses durable, low mass components for excellent performance under heavy duty vibration and shock conditions. The 9012G pressure switches line offers devices with either diaphragm or piston actuators—for optimum life, versatility, and speed of operation. A variety of modifications are available (see page 91). Features include the following: High shock resistanceDual numerical range scale (psi and kPa) High set-point stabilityOne or two SPDT double-break contacts Internal or external range adjustmentAdjustable or fixed (fixed) differential No drain line requiredSingle-stage, dual-stage, or differential-pressure operation The 9012G diaphragm switches range from 0.2–675 psi falling pressure. Buna-N diaphragms and ® zinc-plated steel flanges are standard. Diaphragms of Viton flourocarbon or ethylene propylene are available as well as stainless steel flanges. The 9012G piston actuated switches range from 20–9,000 psi falling pressure. They have sealed pistons and can be used on air, water, oil, or any media compatible with the actuator material. The switches come standard with stainless steel pistons and housings, Viton diaphragms and O-ring seals, ® and Teflon retaining rings. Ethylene propylene diaphragms and O-ring seals are also available. The 9012G industrial pressure switches are available as open type or in NEMA Type 1 enclosures. The backplate is steel with a plastic cover. Open devices in pressure ranges up to 250 psi are available with internal- or external-threaded pressure connectors, ideally suiting them for panel mounting. The 9012G machine tool pressure switches with NEMA Type 4, 4X, or 13 (IP66) cast aluminum enclosures are UL Listed and CSA Certified as industrial control equipment. They are also UL Marine Listed for use on vessels greater than 65 ft long where ignition protection is not required. The 9012G machine tool switches are also available in NEMA Type 7 & 9 cast aluminum enclosures. These are UL Listed for use in Class I, Divisions 1 and 2, Groups C and D, and Class II, Divisions 1 and 2, Groups E, F, G hazardous locations. Application and General Information 9012 pressure switches can generally be used in any application where electrical contacts must open or close in response to a system pressure change, within the electrical and pressure ratings of the switch. Pressure switches are used in a wide variety of applications such as the following: compressed air systemsstamping presses HVAC equipmentautomatic grinders chillerswelders pumping systemsprocess equipment machine toolsmolding machines Pressure switches typically perform one of the following two functions: Monitoring the pressure in the system. The switch can be used either as an interlock that sequences operations in an automatic system, or to give an audio or visual signal, typically an alarm of an undesired condition, at predetermined pressures. A switch with a fixed differential is generally used in these applications. Controlling the pressure in the system by starting and stopping a pump or a compressor at predetermined pressures. A switch with an adjustable differential is usually needed in these applications. 79 © 1998–2009 Schneider Electric 10/2009 All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Introduction Industrial Pressure Switches 9012G Pressure Switches Diaphragm Life The elastomer diaphragms used on 9012G switches can withstand high speed cycling and wide pressure changes. They can tolerate operating speeds up to 200 cycles per minute with no negative impact on the life of the diaphragm. Diaphragm life is affected by pressure medium compatibility. Standard diaphragms on 9012G devices are Buna-N nitrile in zinc-plated steel flanges. Also available are Viton fluorocarbon and ethylene propylene diaphragms, as well as Type 316 stainless steel flanges. The diaphragm can withstand wide pressure changes on each operating cycle. However, the pressure applied to the diaphragm during the normal operating cycle should never exceed the maximum value listed in the Range column in the catalog listing. Regularly cycling the pressure above this value reduces life considerably. If significant surges are common, or if pressures are higher than those listed in the Range column, consider using a piston device. Piston Life For long piston life, the pressure medium should be filtered to keep foreign matter such as dirt and chips out of the piston assembly. 9012G sealed piston devices are not recommended for use on dry gas media, since this usage could cause some leakage past the seal. Depending on the gas, the media pressure, and the rate of operation, the amount of leakage could render the switch inoperable. (Note, however, that some weepage of the media is necessary to lubricate the seals. This small amount of weepage does not indicate a problem.) Surges One of the most destructive conditions for a pressure switch is hydraulic surge. A surge is a high rate of rise in pressure, normally of short duration, caused by starting a pump or by opening and closing a valve. Extremely high rates of rise in pressure can be damaging even if they are within the limits of the maximum allowable pressure. To limit the effect of surges, the switch should be mounted as close to an accumulator and as far from the pump or quick acting valve as possible. The 9012G piston actuated switches have a 0.020 in. pressure orifice to help reduce the effects of minor surges. 9012G diaphragm actuated switches have a 0.060 in. pressure orifice. A restrictor with a small orifice placed in the line between the switch and the pump or valve will further help to protect the switch. Using a surge snubber such as the 9049A26 or A26S will also protect the switch. Vibration Among other things, excessive vibration can cause contact bounce, chatter, or premature contact transfer, especially when system pressure is near the operating point of the switch. Remote mounting of the switch is the best way to avoid problems. Use on Steam Switches should not be applied directly on steam exceeding 15 psig. However, with steam capillary tubing installed between the pressure connection and the switch, steam pressure up to 250 psig can be applied—provided this does not exceed the maximum allowable pressure rating of the switch or the maximum temperature rating at the actuator. Refer to the instruction bulletin supplied with the device. Dual-Stage Operation The 9012G dual-stage pressure switches provide two distinct levels of control from one device. These switches are most commonly used where dual functions are required, or in sequencing applications such as alarm-shutdowns. Differential-Pressure Operation The 9012G pressure switches for differential-pressure sensing can monitor changes in the difference between two pressures. These unidirectional devices signal that a predetermined pressure difference was reached, resulting from a widening or narrowing of the difference between two pressures. 80 10/2009 © 1998–2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Technical Overview Industrial Pressure Switches 9012G Pressure Switches Piston- vs. Diaphragm-Actuated Devices Selecting between piston and diaphragm devices depends on several criteria: maximum allowable pressure range and differential surges medium (whether hydraulic or pneumatic) Maximum allowable pressures for piston devices are much higher than for diaphragm devices. Most diaphragm devices have a maximum allowable pressure of 850 psi or less, whereas all piston devices have a maximum allowable pressure of 10,000 psi or more. Range and differential for diaphragm devices are lower than for piston devices. Many applications call for a low differential, such as 20 psi. This may exclude piston devices, which have a minimum differential of 60 psi or more. Surges are a part of every hydraulic system. While many are small and have only a small effect on the switch, some are significant and can potentially destroy a pressure switch. Diaphragm devices are the most sensitive to surges and are most easily damaged. Piston devices are more tolerant of surges and last longer in the same application. Hydraulic systems, which typically use oil-based media, are more demanding applications than pneumatic systems. Pressure switches used in hydraulic applications typically experience higher pressures, have wider pressure variations, and produce more surges, since the medium does not compress. Pneumatic systems, which typically use air, place fewer demands on a system, since these applications typically experience lower pressures and the medium can compress, cushioning the effects of surges. Table 66 offers basic guidelines for determining the selection of a piston- versus a diaphragm-operated pressure switch. Table 66: Piston vs. Diaphragm High Piston Maximum allowable pressures Lower Diaphragm High pressures Piston Pressures Low differentials or pressures Diaphragm Constant Piston Surges Minimal Diaphragm or piston Hydraulic systems Piston Media Pneumatic systems Diaphragm Technical Overview Operating Points (Set Points) Pressure switches have two operating points: Increasing pressure operating point (rising pressure) Decreasing pressure operating point (falling pressure) These operating points are also called the set points of the switch. Differential The differential is the difference in pressure between the rising and falling pressure points. It can be adjustable or fixed. Range The range refers to the pressure limits within which the operating points (settings) can be adjusted. The range of the 9012G pressure switch is tied to the decreasing pressure operating point. Adding the differential to the decreasing pressure operating point determines the increasing pressure operating point. 81 © 1998–2009 Schneider Electric 10/2009 All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Technical Overview Industrial Pressure Switches 9012G Pressure Switches Figure 1: Differential Adjustable Differential Fixed Differential Maximum Allowable Pressure Maximum Allowable Pressure Maximum Differential Max. Trip Point Trip Point Min. Trip Point Minimum Differential Reset Point Reset Point 0 psi 0 psi Fixed Differential To determine the operating range on rising pressure for a fixed differential switch, add the differential to the decreasing pressure operating point. For example, to determine the range on increasing pressure for a 9012GDW5 switch: 1. Range on decreasing pressure = 3 to 150 psi 2. Fixed differential = 6.0 ± 0.8 psi 3. Range on increasing pressure = 9 ± 0.8 to 156 ± 0.8 psi Adjustable Differential For adjustable differential switches, add the minimum differential to the low end of the range and the maximum differential to the high end of the range. For example, to determine the range on increasing pressure for a 9012GAW5: 1. Range on decreasing pressure = 3 to 150 psi 2. Adjustable differential = 6.0 to 30 psi 3. Range on increasing pressure = 9 to 180 During the normal operating cycle, system pressure should never exceed the upper limit of the range when using a diaphragm actuated switch. This greatly reduces the life of the diaphragm. For optimum life, operate the switch in the middle 80% of the range. Maximum Allowable Pressure Maximum allowable pressure is the pressure to which a switch can be subjected without causing a change in operating characteristics, shift in settings, or damage to the device. System pressure surges may occur during machine startup or from valve operation. Surges are not normally detrimental to the life of a switch if the surge is within the maximum allowable pressure rating of the switch. Diaphragm actuated switches should not be subjected to more than 10 surges per day. More frequent surges greatly reduce the life of the diaphragm. 82 10/2009 © 1998–2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Adjustable Range—Rising Pressure Adjustable Range—Falling Pressure Adjustable Differential Adjustable Range—Rising Pressure Adjustable Range—Falling Pressure Fixed Differential 4 8 3 4 3 7 1 2 2 6 1 5 Technical Overview Industrial Pressure Switches 9012G Pressure Switches Specifications Environment Table 67: Environmental Specifications Conformity to standards CE, IEC 60957.5.1, UL 508, CSA 3211-03 Product certifications UL Listed and CSA Certified as industrial control equipment Protective treatment Marine use: "HT" (does not apply to 9016GVG) Fluids controlled Air, water, hydraulic oils, gases, steam (depending on the model) Cast aluminum enclosures (9012 NEMA 1 and 9016 GVG are Materials stamped metal enclosure and molded cover) Operating position Operates in all positions Shock resistance 50 g Degree of protection Depends on model Operating rate (operating cycles/minute) 120 operations/minute max. 9016GVG: 60 operations/minute max. Repeat accuracy ±0.1 to ±1.0% (does not apply to 9016GVG) Drift ±1.0% of the adjustable range over 1 million operations Pressure connection G1/4 (BSP) female, 1/4" NPTF, or 1/2”-14 NPT 1/2”-14 NPTF, PG13.5, or ISO M20 (also, 3/4”-14 NPTF available only on Electrical connection NEMA 7 and 9). NEMA 1 is 1/2” conduit entry, unthreaded. (does not apply to 9016 GVG) Contact Arrangement Table 68: 9012G Machine Tool and Vacuum Switches (except GVG) Type Contact Arrangement Contact Symbol Single Pole Same Double Throw 1 N.O., 1 N.C. Polarity (SPDT) Snap switch contains two double-break contact elements (1 N.O. and 1 N.C.) that must be used on circuits of same polarity. Same Double Pole Polarity Double Throw 2 N.O., 2 N.C. Same (DPDT) Polarity Snap switch contains two electrically separated sets of contact elements allowing use on circuits of opposite polarity. Each set contains two double-break contact elements (1 N.O. and 1 N.C.) that must be used on circuits of same polarity. Table 69: Circuit Ratings AC—50 or 60 Hz DC AC or DC Resistive Inductive Inductive 75% Power 35% Power Factor and Resistive Continuous Factor Carrying Make and Break Make and Make Break Amperes Amperes Break A VA A VA Amperes Single Throw Double Throw 120 60 7200 6 720 6 125 0.55 0.22 10 240 30 7200 3 720 3 250 0.27 0.11 10 SPDT (1) 480 15 7200 1.5 720 1.5 600 0.10 — 10 600 12 7200 1.2 720 1.2 — — — — 120 60 7200 6 720 6 125 0.22 0.22 10 240 30 7200 3 720 3 250 0.11 0.11 10 DPDT 480 15 7200 1.5 720 1.5 600 — — 10 600 12 7200 1.2 720 1.2 — — — — (1) 600 Vdc rating does not apply. Acceptable Wire Sizes: 12–22 AWG. Recommended Terminal Clamp Torque: 7 in-lbs Not recommended for use on circuits below 24 V, 20 mA. 83 © 1998–2009 Schneider Electric 10/2009 All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Contacts Voltage (V) Voltage (V) Technical Overview Industrial Pressure Switches 9012G Pressure Switches Table 70: Interpreting the Catalog Number (excluding 9016GVG) 9012G A R 2 2 Designation Catalog Number Pressure Switch 9012G Classification Vacuum Switch 9016G Diaphragm, Low Pressure—Adjustable A Diaphragm, High Pressure—Adjustable B Piston—Adjustable C Single-Stage Diaphragm, Low Pressure—Fixed D Diaphragm, High Pressure—Fixed E Actuator Type— Piston—Fixed F Differential Type Diaphragm, Low Pressure—Adjustable G Differential-Pressure Diaphragm, High Pressure—Adjustable H Piston— Adjustable J Diaphragm, Low Pressure—Adjustable K Dual-Stage Diaphragm, High Pressure—Adjustable L Piston—Adjustable M 1 G Open O Enclosure, NEMA Type 7, 9 R 4, 4X, 13 W Single-pole, double-throw blank Contacts Double-pole, double-throw 2 0.2–10 1 1–40 2 Single or Dual Stage, Low Pressure 1.5–75 4 3–150 5 5–250 6 Diaphragm 13–425 1 Single or Dual Stage, High Pressure 20–675 2 Pressure 0–75 1 Range (psi) Differential-Pressure, Low Pressure 0–175 4 Differential-Pressure, High Pressure 0–500 1 20–1000 1 90–2900 2 Single or Dual Stage Piston 170–5600 3 270–9000 4 Differential-Pressure 0–5000 1 0–28 1 Vacuum (inHg) Diaphragm Single Stage, Low Pressure 0–25 2 See Tables 78–80 on page 91, Options Factory modifications and accessories Table 83 on page 93, and Table 89 on page 99 Use this table for interpretation only. Some combinations are not available. Table 71: Pressure Range (psi)—Contacts Change on Decreasing Pressure Actuator Switch Style Range (psi) Fixed Differential Adjustable Differential Pressure Code 0.2–10 0.6±0.1 0.6–2 1 1–40 1.6±0.4 1.6–8 2 Single or Dual Stage, 1.5–75 3.0±0.5 3.5–15 4 Low Pressure 3–150 6.0±0.8 6.0–30.0 5 5–250 10.0±1.5 10.0–49 6 Diaphragm 13–425 16±3.5 16–90 1 Single or Dual Stage, High Pressure 20–675 27±5 27–130 2 0–75 0.25±10 0.25–10 1 Differential-Pressure, Low Pressure 0–175 — 0.5–36 4 Differential-Pressure, High Pressure 0–500 — 3–175 1 20–1000 89±18 89–200 1 90–2900 255±30 255–560 2 Single or Dual Stage Piston 170–5600 578±110 578–1260 3 270–9000 788±140 788–1900 4 Differential-Pressure 0–5000 — 15–825 1 84 10/2009 © 1998–2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 4 8 3 4 3 7 2 6 1 2 1 5 Selection and Specifications Industrial Pressure Switches 9012G Pressure Switches Selection and Modifications 9012G Machine Tool Pressure Switches for Single-Stage Operation The 9012G single-stage pressure switches are control circuit rated devices. These switches are used in pneumatic or hydraulic systems on a wide variety of machine and process applications to protect the equipment. They either control or monitor the system pressure. Table 72: Fixed Differential NEMA Type 4, 4X, 13 Enclosure UL Listed and CSA Certified as Industrial Control Equipment Range on Maximum Class 9012 Type Approximate Differential At Decreasing Pressure Allowable (1) Mid Range, psig SPDT DPDT psig Pressure, psig Diaphragm Actuated – Buna-N Nitrile Diaphragm, Zinc Plated Steel Housing 0.2–10 0.6 ± 0.1 100 GDW1 GDW21 9012GDW1 1–40 1.6 ± 0.4 100 GDW2 GDW22 1.5–75 3.0 ± 0.5 240 GDW4 GDW24 3–150 6.0 ± 0.8 475 GDW5 GDW25 5–250 10.0 ± 1.5 750 GDW6 GDW26 13–425 16 ± 3.5 850 GEW1 GEW21 20–675 27 ± 5 2000 GEW2 GEW22 Piston Actuated – #440 Stainless Steel Piston. ® ® #303 Stainless Steel Housing, Viton Fluorocarbon Diaphragm and O-ring, Teflon Retaining Ring 20–1000 59 ± 9 10000 GFW1 GFW21 90–2900 170 ± 15 15000 GFW2 GFW22 170–5600 289± 55 20000 GFW3 GFW23 270–9000 495 ± 70 25000 GFW4 GFW24 Specifications Fluids Controlled Air, water, hydraulic oils, gases, steam (depending on the model) Pressure connection G1/4 (BSP) female, 1/4" NPTF, or 1/2”-14 NPT. For metric threads, add M after the W on all types. Weight (approximate) 3 lb (1.36 kg) Voltage Limits 600 V Continuous Current 10 A Electrical Connections 1/2”-14 NPTF, PG13.5, or ISO M20. For metric threads, add M after the W on all types. CE, IEC 60957.5.1, UL 508, CSA 3211-03. UL Marine Listed for use on ships/vessels greater than Standards/Ratings 65 ft long where ignition protection is not required. Temperature Ratings Minimum Maximum Ambient –23 °C (–10 °F) +85 °C (+185 °F) Diaphragm –40 °C (–40 °F) Media Piston –26 °C (–15 °F) +120 °C (+250 °F) All with Form Q4 –26 °C (–15 °F) Operating Curves Contact Blocks Connection 1 N.O., Form H17 Max. Differential 1N.C. Same Brown Polarity Fixed White Differential Red 4 8 2 1 2 N.O., 34 Min. Differential LED 2 6 2N.C. Black Same Polarity Black Blue 1 Same Falling pressure Polarity Form H10 Form H11 SPDT snap switches contain two double-break contact elements ORG ORG WHT RED (1 N.O., 1 N.C.) that must be used on circuits of the same polarity. GRN GRN 4 8 4 8 BLK DPDT snap switches contain two electrically separated sets of 3 3 4 2 4 2 BLK contact elements allowing use on circuits of opposite polarity. 26 26 5 1 5 1 Each set contains two double-break contact elements (1 N.O., 1 1 WHT RED 1 N.C.) that must be used on circuits of the same polarity. Acceptable Wire Sizes: 12–22 AWG Recommended Terminal Clamp Torque: 7 lb-in (1) The differential adds to the range setting and determines the operating point on rising pressure. 85 © 1998–2009 Schneider Electric 10/2009 All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Rising Pressure 4 8 3 4 3 7 2 6 1 2 1 5 Selection and Specifications Industrial Pressure Switches 9012G Pressure Switches Table 73: Fixed Differential NEMA Type 7 & 9 Enclosure, Class I & II, Division 1 & 2, Groups C, D, E, F, G UL Listed as Industrial Control Equipment Approximate Differential At Maximum Class 9012 Type Range on Decreasing Mid Range Allowable Pressure, psig SPDT DPDT (1) psig Pressure, psig Diaphragm Actuated – Buna-N Nitrile Diaphragm, Zinc Plated Steel Housing 0.2–10 1.0 ± 0.1 100 GDR1 GDR21 1–40 2.4 ± 0.8 100 GDR2 GDR22 1.5–75 4.5 ± 1 240 GDR4 GDR24 3–150 9 ± 1.5 475 GDR5 GDR25 5–250 15 ± 3 750 GDR6 GDR26 13–425 25 ± 7 850 GER1 GER21 20–675 41 ± 10 2000 GER2 GER22 9012GDR Piston Actuated – #440 Stainless Steel Piston. ® ® #303 Stainless Steel Housing, Viton Fluorocarbon Diaphragm and O-ring, Teflon Retaining Ring 20–1000 89 ± 18 10000 GFR1 GFR21 90–2900 255 ± 30 15000 GFR2 GFR22 170–5600 578 ± 110 20000 GFR3 GFR23 270–9000 788 ± 140 25000 GFR4 GFR24 Specifications Fluids Controlled Air, water, hydraulic oils, gases, steam (depending on the model) Pressure Connection G1/4 (BSP) female, 1/4" NPTF, or 1/2”-14 NPT Weight (approximate) 10 lb (4.54 kg) Voltage Limits 600 V Continuous Current 10 A Electrical Connections 1/2”-14 NPTF, PG13.5, 3/4”-14 NPTF, or ISO M20 CE, IEC 60957.5.1, UL 508, CSA 3211-03. UL Marine Listed for use on vessels greater than 65 ft Standards/Ratings long where ignition protection is required. Temperature Ratings Minimum Maximum Ambient –23 °C (–10 °F) +85 °C (+185 °F) Diaphragm –40 °C (–40 °F) Media Piston –26 °C (–15 °F) +120 °C (+250 °F) All with Form Q4 –26 °C (–15 °F) Operating Curves Contact Blocks Connection Form H17 Max. Differential 1 N.O., Same Brown 1N.C. Polarity Fixed White Differential 4 8 Red 2 1 34 Min. Differential LED 2 6 Black 2 N.O., Same Polarity 2N.C. Black 1 Blue Same Falling pressure Polarity Form H10 Form H11 SPDT snap switches contain two double-break contact elements ORG ORG WHT RED (1 N.O., 1 N.C.) that must be used on circuits of the same polarity. GRN GRN 4 4 8 8 DPDT snap switch contain two electrically separated sets of BLK 3 3 4 2 BLK 4 2 contact elements allowing use on circuits of opposite polarity. 26 26 5 1 5 1 Each set contains two double-break contact elements (1 N.O., 1 1 RED WHT 1 N.C.) that must be used on circuits of the same polarity. Acceptable Wire Sizes: 12–22 AWG Recommended Terminal Clamp Torque: 7 lb-in (1) The differential adds to the range setting and determines the operating point on rising pressure. NOTE: When pressure settings of the switches must be factory set (Form Y1), and only one setting is identified, specify whether this setting is on increasing or decreasing pressure. File E12443 CCN NOWT Haz. Loc., G•R File LR 25490 Class 3211-03 G•W, G•O, G•G File E12158 CCN NKPZ G•W, G•O, G•G File LR 26817 Class 3218-02 G•R File E12158 CCN NTHT Marine Use, G•W 86 10/2009 © 1998–2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Rising Pressure 4 8 3 4 3 7 2 6 1 2 1 5 Selection and Specifications Industrial Pressure Switches 9012G Pressure Switches Table 74: Adjustable Differential NEMA Type 4, 4X, 13 Enclosure UL Listed and CSA Certified as Industrial Control Equipment (1) Class 9012 Type Range on Decreasing Adjustable Differential Maximum Allowable Pressure, psig Approximate at Mid Range Pressure, psig SPDT DPDT Diaphragm Actuated—Buna-N Nitrile Diaphragm, Zinc Plated Steel Housing 0.2–10 0.6–2 100 GAW1 GAW21 1–40 1.6–8 100 GAW2 GAW22 1.5–75 3.5–15 240 GAW4 GAW24 3–150 6.0–30 475 GAW5 GAW25 5–250 10.0–49 750 GAW6 GAW26 13–425 16–90 850 GBW1 GBW21 20–675 27–130 2000 GBW2 GBW22 Piston Actuated – #440 Stainless Steel Piston. ® ® #303 Stainless Steel Housing, Viton Fluorocarbon Diaphragm and O-ring, Teflon Retaining Ring 9012GAW1 20–1000 59–200 10000 GCW1 GCW21 90–2900 170–560 15000 GCW2 GCW22 170–5600 289–1260 20000 GCW3 GCW23 270–9000 495–1900 25000 GCW4 GCW24 Specifications Fluids Controlled Air, water, hydraulic oils, gases, steam (depending on the model) Pressure Connection G1/4 (BSP) female, 1/4" NPTF, or 1/2”-14 NPT. For metric threads, add M after the W on all types. Weight (approximate) 3 lb (1.36 kg) Voltage Limits 600 V Continuous Current 10 A Electrical Connections 1/2”-14 NPTF, PG13.5, or ISO M20. For metric threads, add M after the W on all types. CE, IEC 60957.5.1, UL 508, CSA 3211-03. UL Marine Listed for use on ships/vessels greater than Standards/Ratings 65 ft long where ignition protection is not required. Temperature Ratings Minimum Maximum Ambient –23 °C (–10 °F) +85 °C (+185 °F) Diaphragm –40 °C (–40 °F) Media Piston –26 °C (–15 °F) +120 °C (+250 °F) All with Form Q4 –26 °C (–15 °F) Operating Curves Contact Blocks Connection Form H17 1 N.O., Brown Same 1N.C. Adjustable Polarity White Differential 4 8 Red 2 1 34 LED 2 6 Black 2 N.O., Same 2N.C. Polarity Black 1 Blue Same Polarity Form H10 Form H11 Falling pressure SPDT snap switches contain two double-break contact elements ORG ORG WHT RED (1 N.O., 1 N.C.) that must be used on circuits of the same GRN GRN 4 4 8 8 polarity. BLK 3 3 4 2 BLK 4 2 DPDT snap switch contain two electrically separated sets of 26 26 5 1 5 1 contact elements allowing use on circuits of opposite polarity. 1 1 WHT RED Each set contains two double-break contact elements (1 N.O., 1 N.C.) that must be used on circuits of the same polarity. Acceptable Wire Sizes: 12–22 AWG Recommended Terminal Clamp Torque: 7 lb-in (1) The differential adds to the range setting and determines the operating point on rising pressure. 87 © 1998–2009 Schneider Electric 10/2009 All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Min. Differential Max. Differential Rising Pressure 4 8 3 4 3 7 2 6 1 2 1 5 Selection and Specifications Industrial Pressure Switches 9012G Pressure Switches Table 75: Adjustable Differential NEMA Type 7 & 9 Enclosure, Class I & II, Division 1 & 2, Groups C, D, E, F, G UL Listed as Industrial Control Equipment (1) Class 9012 Type Range on Decreasing Adjustable Differential Maximum Allowable Pressure, psig Approximate at Mid Range Pressure, psig SPDT DPDT Diaphragm Actuated – Buna-N Nitrile Diaphragm, Zinc Plated Steel Housing 0.2–10 1.0–2 100 GAR1 GAR21 1–40 2.4–8 100 GAR2 GAR22 1.5–75 4.5–15 240 GAR4 GAR24 3–150 9–35 475 GAR5 GAR25 5–250 15–49 750 GAR6 GAR26 13–425 25–90 850 GBR1 GBR21 20–675 41–130 2000 GBR2 GBR22 Piston Actuated – #440 Stainless Steel Piston. 9012GAR ® ® #303 Stainless Steel Housing, Viton Fluorocarbon Diaphragm and O-ring, Teflon Retaining Ring 20–1000 89–200 10000 GCR1 GCR21 90–2900 255–560 15000 GCR2 GCR22 170–5600 578–1260 20000 GCR3 GCR23 270–9000 788–1900 25000 GCR4 GCR24 Specifications Fluids Controlled Air, water, hydraulic oils, gases, steam (depending on the model) Pressure Connection G1/4 (BSP) female, 1/4" NPTF, or 1/2”-14 NPT Weight (approximate) 10 lb (4.54 kg) Voltage Limits 600 V Continuous Current 10 A Electrical Connections 1/2”-14 NPTF, PG13.5, 3/4”-14 NPTF, or ISO M20 CE, IEC 60957.5.1, UL 508, CSA 3211-03. UL Marine Listed for use on vessels greater than 65 ft Standards/Ratings long where ignition protection is required. Temperature Ratings Minimum Maximum Ambient –23 °C (–10 °F) +85 °C (+185 °F) Diaphragm –40 °C (–40 °F) Media Piston –26 °C (–15 °F) +120 °C (+250 °F) All with Form Q4 –26 °C (–15 °F) Operating Curves Contact Blocks Connection Form H17 Brown Adjustable White Differential 4 8 1 N.O., Red 2 1 Same 1N.C. 34 Polarity LED 2 6 Black Black 1 Blue 2 N.O., Same Form H10 Form H11 2N.C. Polarity Falling pressure ORG ORG Same WHT RED Polarity GRN GRN 4 8 4 8 BLK 3 3 4 2 4 2 BLK 26 26 5 1 5 1 1 1 RED WHT SPDT snap switches contain two double-break contact elements (1 N.O., 1 N.C.) that must be used on circuits of the same polarity. DPDT snap switch contain two electrically separated sets of contact elements allowing use on circuits of opposite polarity. Each set contains two double-break contact elements (1 N.O., 1 N.C.) that must be used on circuits of the same polarity. Acceptable Wire Sizes: 12–22 AWG Recommended Terminal Clamp Torque: 7 lb-in (1) The differential adds to the range setting and determines the operating point on rising pressure. File E12443 CCN NOWT Haz. Loc., G•R File LR 25490 Class 3211-03 G•W, G•O, G•G File E12158 CCN NKPZ G•W, G•O, G•G File LR 26817 Class 3218-02 G•R File E12158 CCN NTHT Marine Use, G•W 88 10/2009 © 1998–2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Min. Differential Max. Differential Rising Pressure 4 8 3 4 3 7 2 6 1 2 1 5 Selection and Specifications Industrial Pressure Switches 9012G Pressure Switches Differential-Pressure Operation Pressure switches for differential-pressure operation are used to monitor the change in the difference between two pressures. The 9012G differential-pressure switches are unidirectional devices and are used in applications to signal that a predetermined pressure difference has been reached as a result of a widening or increasing difference between the two pressures. They can also be used in applications to signal that a predetermined pressure difference has been reached as a result of a narrowing or decreasing difference between the two pressures. Table 76: Adjustable differential NEMA Type 4, 4X, 13 Enclosures UL Listed and CSA Certified as Industrial Control Equipment Adjustable Class 9012 Type Adjustable Difference on Differential Maximum Working Pressure Decreasing Pressure Actuates on Allowable Range on decreasing increasing pressure SPDT DPDT (Adds to X (upper) actuator Pressure (adds to adjustable working pressure) difference) Y (lower) actuator Diaphragm Actuated – Buna-N Nitrile Diaphragm, Zinc Plated Steel Housing 0–75 0.25–10 0.8–2 100 GGW1 GGW21 0–175 0.5–36 5–15 240 GGW4 GGW24 0–500 3–175 22–90 850 GHW1 GHW21 Piston Actuated – #440 Stainless Steel Piston. 9012GJW1 ® ® #303 Stainless Steel Housing, Viton Fluorocarbon Diaphragm and O-ring, Teflon Retaining Ring 0–5000 15–825 80–200 7500 GJW1 GJW21 Specifications Fluids Controlled Air, water, hydraulic oils, gases, steam (depending on the model) Pressure Connection G1/4 (BSP) female, 1/4" NPTF, or 1/2”-14 NPT Weight (approximate) 3 lb (1.36 kg) Voltage Limits 600 V Continuous Current 10 A Electrical Connections 1/2”-14 NPTF, PG13.5, or ISO M20 CE, IEC 60957.5.1, UL 508, CSA 3211-03. UL Marine Listed for use on vessels greater than Standards/Ratings 65 ft long where ignition protection is not required. Temperature Ratings Minimum Maximum Ambient –23 °C (–10 °F) +85 °C (+185 °F) Diaphragm –40 °C (–40 °F) Media Piston –26 °C (–15 °F) +120 °C (+250 °F) All with Form Q4 –26 °C (–15 °F) Operating Curves Contact Blocks Connection Form H17 Brown 1 N.O., Same Adjustable 1N.C. Polarity White Differential Red 4 8 2 1 34 LED 2 6 Black Same 2 N.O., Black 1 Blue Polarity 2N.C. Same Polarity Form H10 Form H11 Falling pressure SPDT snap switches contain two double-break contact elements (1 N.O., ORG ORG WHT RED 1 N.C.) that must be used on circuits of the same polarity. GRN GRN 4 8 4 8 BLK DPDT snap switch contain two electrically separated sets of contact 3 3 BLK 4 2 4 2 26 elements allowing use on circuits of opposite polarity. Each set contains two 26 5 1 5 1 double-break contact elements (1 N.O., 1 N.C.) that must be used on circuits 1 1 RED WHT of the same polarity. Recommended Acceptable Wire Sizes: 12–22 AWG 7 lb-in Terminal Clamp Torque: FileE12158 CCNNKPZ File LR25490 Class 3211-03 File E12158 CCN NTHT - Marine Use 89 © 1998–2009 Schneider Electric 10/2009 All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Min. Differential Max. Differential Rising Pressure 3 4 1 2 Selection and Specifications Industrial Pressure Switches 9012G Pressure Switches Dual-Stage Operation The 9012G dual-stage pressure switches are designed for use in applications where two separate pressure operations must be controlled by a single pressure monitoring device. These controls are most commonly used where dual functions are required or in sequencing applications such as alarm shutdowns. The spread between the two stages is adjustable, but the differential between the high (rising) and low (falling) operating points of each stage is fixed. Table 77: Fixed Differential NEMA Type 4, 4X, 13 Enclosure UL Listed and CSA Certified as Industrial Control Equipment Fixed Differential Range Setting Adjustable Spread SPDT Each Maximum Add to the low operating point to Pressure limits between 9012GKW1 Add to the range setting obtain the approximate high Stage Allowable which Stage 1 can be to obtain the decreasing operating point for each stage adjusted to operate on Pressure operating point of Stage 2 decreasing pressure Stage 1 Stage 2 Type Diaphragm Actuated – Buna-N Nitrile Diaphragm, Zinc Plated Steel Housing 0.2–10 1–5 1.0 ± 0.2 1.5 ± 0.4 100 GKW1 1–40 4–20 4.0 ± 1.0 6.0 ± 1.5 100 GKW2 1.5–75 6–30 5.0 ± 1.5 8.0 ± 2.0 240 GKW4 3–150 12–75 8.0 ± 2.0 12 ± 3 475 GKW5 5–250 22–110 14 ± 3 21 ± 5 750 GKW6 13–425 40–180 20 ± 4 30 ± 7.5 850 GLW1 20–675 45–250 30 ± 6 45 ± 11 2000 GLW2 Piston Actuated – #440 Stainless Steel Piston. ® ® #303 Stainless Steel Housing, Viton Fluorocarbon Diaphragm and O-ring, Teflon Retaining Ring 20–1000 50–300 50 ± 10 75 ± 19 10000 GMW1 90–2900 140–800 140 ± 30 210 ± 52 15000 GMW2 170–5600 300–1700 275 ± 60 400 ± 100 20000 GMW3 270–9000 500–2500 400 ± 80 800 ± 150 25000 GMW4 Specifications Fluids Controlled Air, water, hydraulic oils, gases, steam (depending on the model) Pressure Connection G1/4 (BSP) female, 1/4" NPTF, or 1/2”-14 NPT Weight (approximate) 3 lb (1.36 kg) Voltage Limits 600 V Continuous Current 10 A Electrical Connections 1/2”-14 NPTF, PG13.5, or ISO M20 CE, IEC 60957.5.1, UL 508, CSA 3211-03. UL Marine Listed for use on vessels greater than 65 ft Standards/Ratings long where ignition protection is not required. Temperature Ratings Minimum Maximum Ambient –23 °C (–10 °F) +85 °C (+185 °F) Diaphragm –40 °C (–40 °F) Media Piston –26 °C (–15 °F) +120 °C (+250 °F) All with Form Q4 –26 °C (–15 °F) Operating Curves Contact Blocks Max. Differential Acceptable Wire Sizes: Fixed 12–22 AWG Differential 1 N.O., Same 1N.C. Polarity Min. Differential Recommended Terminal Clamp Torque: 7 lb-in Falling pressure FileE12158 CCNNKPZ File LR25490 Class 3211-03 File E12158 CCN NTHT - Marine Use 90 10/2009 © 1998–2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Rising Pressure Selection and Specifications Industrial Pressure Switches 9012G Pressure Switches Table 78: 9012G Machine Tool Modifications ORG Modification Applies To Form WHT Lock on rising pressure, manual reset only Available on GDW, GDWM, GEW, GEWM, GFW, GFWM only E3 BLK GRN 4 8 clear lens G17 Available on all GAW thru GMW and 3 120 Vac or Vdc neon pilot light 4 2 26 GAWM thru GFWM red lens G18 5 1 clear lens G21 For pilot light conversion kits: 1 RED 24 Vdc only LED See 9998PC306 through 308 red lens G22 Form H10 Class 9012 GAW–GMW and GAWM–GFWM, or 24 Vdc LED pilot light with green lens G23 Class 9016 GAW SPDT snap switch rated 1.1 A at 125 Vdc Available on GAR thru GFR, GAW thru GJW, GAWM thru ORG H3 RED (minimum differential doubles) GFWM GRN Prewired 5-pin male receptacle 4 8 H10 Brad Harrison #41310 or interchangeable Crouse-Hinds Available on GAW thru GJW single pole devices only 3 4 2 or BLK receptacle at our convenience. For use with Brad Harrison See diagrams at left 26 5 1 H11 female portable plug #41306, 41307, 41308 or equal 1 Micro connector, 4-pin, for 24 Vdc pilot light G•W (single pole only), except GAW2 and Form B2. H17 WHT Form H11 External range With knob GAW thru GFW, GAWM thru GFWM, GKW thru GMW K adjustment with Slotted for screwdriver GAW thru GFW, GAWM thru GFWM, GKW thru GMW K1 range scale window Brown Pg 13.5 conduit thread and ¼-19 BSP pressure GAW thru GFW, GKW thru GMW M12 connection White Red 4 8 2 1 GAR, GBR, GDR, GER, GAW, GBW, GDW, GEW, GGW, Standard Buna-N Nitrile diaphragm Q1 34 GHW, GAWM, GBWM, GDWM, GEWM, GKW, GLW LED 2 6 Black Available on all GGW, GHW except GGW-1, 21. Black Blue 1 #316 stainless Available on all GAR, GBR, GDR, GER, GAW, GBW, GDW, Ethylene propylene diaphragm Q3 steel flange GEW, GAWM, GBWM, GDWM, GEWM, GKW, GLW except Form H17 Types 1 and 21 GAR, GAW, GBR, GBW, GDR, GDW, GER, GEW, GGW, ® Viton fluorocarbon diaphragm Q4 GHW, GAWM, GBWM, GDWM, GEWM, GKW, GLW Range scale window (standard with Forms K and K1) GAW thru GMW, GAWM thru GFWM V1 Special factory setting specified (If indicating only one special setting, specify whether this All 9012G Y1 setting is on increasing or decreasing pressure.) GAR, GAW, GDR, GDW, GGW, GKW 1⁄4"-18 NPT external thread Z Not available in combination with Forms Q1, Q3, Q4 Pressure 1⁄2"-14 NPT external thread, GAR, GAW, GDR, GDW, GGW, GKW Z16 connection 1⁄4"-18 NPTF internal thread Not available in combination with Forms Q1, Q3, Q4 GAR thru GFR; GAW thru GMW 7⁄16"-20 UNF-2B internal thread Z18 Not available in combination with Forms Q1, Q3, Q4 Table 79: Factory Modifications for Renewal Parts Kits for Class 9012 Pressure Switches Suffixes for renewal parts kits, see page 26. Modification Applies to Parts Kit Type Form SPDT snap switch rated 1.1 A at 125 Vdc PC313 H3 (minimum differential doubles) PC177–179, PC268, 269 Standard Buna-N Nitrile diaphragm Q1 PC265–267 PC177–178, PC268, 269 #316 stainless steel Ethylene propylene diaphragm Q3 flange PC266, 267 PC177–178, PC268, 269 ® Viton fluorocarbon diaphragm Q4 PC265–267 1⁄4"-18 NPT external thread PC265–269 Z Pressure 1⁄2"-14 NPT external thread, PC265–269 Z16 connection 1⁄4"-18 NPTF internal thread 7⁄16"-20 UNF-2B internal thread PC177, 178, PC265–273 Z18 Table 80: Class 9049 Accessories for 9012G Pressure Switches Description Type Stainless steel surge reducer for use on oils, coolants, and hydraulic fluids (not recommended for air or water) A26S 91 © 1998–2009 Schneider Electric 10/2009 All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Selection and Specifications Industrial Pressure Switches 9012G Pressure Switches Table 81: Fixed Differential Open Type or NEMA Type 1 Enclosure UL Listed and CSA Certified as Industrial Control Equipment (1) Class 9012 Type Range on Decreasing Approximate Differential Maximum Allowable Pressure, psig At Mid Range, psig Pressure, psig Open Type NEMA Type 1 Diaphragm Actuated – Buna-N Nitrile Diaphragm, Zinc Plated Steel Housing 0.2–10 0.4 ± 0.1 100 GRO1 GRG1 1–40 1.2 ± 0.3 100 GRO3 GRG3 1.5–75 2.2 ± 0.4 240 GRO4 GRG4 3–150 4.2 ± 1 475 GRO5 GRG5 5–250 7.4 ± 2 750 GRO6 GRG6 13–425 13 ± 3 850 GSO1 GSG1 20–675 19 ± 5 2000 GSO2 GSG2 Piston Actuated – #440 Stainless Steel Piston. ® ® #303 Stainless Steel Housing, Viton Fluorocarbon Diaphragm and O-Ring, Teflon Retaining Ring. 20–1000 49 ± 10 10000 GTO1 GTG1 9012GRG5 90–2900 141 ± 15 15000 GTO2 GTG2 170–5600 200 ± 40 20000 GTO3 GTG3 270–9000 350 ± 45 25000 GTO4 GTG4 Specifications Fluids Controlled Air, water, hydraulic oils, gases, steam (depending on the model) Pressure Connection G1/4 (BSP) female, 1/4" NPTF, or 1/2”-14 NPT Weight (approximate) Type 1: 2 lb (0.91 kg); Open: 1.7 lb (0.77) Voltage Limits 600 V Continuous Current 10 A Electrical Connections 1/2” conduit entry, unthreaded Standards/Ratings CE, IEC 60957.5.1, UL 508, CSA 3211-03 Temperature Ratings Minimum Maximum Ambient –23 °C (–10 °F) +85 °C (+185 °F) Diaphragm –40 °C (–40 °F) Media Piston –26 °C (–15 °F) +120 °C (+250 °F) All with Form Q4 –26 °C (–15 °F) Operating Curves Contact Blocks Max. Differential SPDT Acceptable Wire Sizes: form C Fixed 12–22 AWG contacts Differential Min. Dif erential f Recommended Terminal Clamp Torque: 7 lb-in Falling pressure (1) Determines the operating point on rising pressure. File E12158 File LR 25490 CCN NKPZ Class 3211-03 92 10/2009 © 1998–2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Rising Pressure Selection and Specifications Industrial Pressure Switches 9012G Pressure Switches Table 82: Adjustable Differential Open Type or NEMA Type 1 Enclosure UL Listed and CSA Certified as Industrial Control Equipment (1) Range on Approximate Mid Range Maximum Class 9012 Type Decreasing Pressure Differential (adds to the Allowable Pressure psig decreasing set point) psig Open Type NEMA Type 1 Diaphragm Actuated—Buna-N Nitrile Diaphragm, Zinc Plated Steel Housing 0.2–10 0.4–0.9 100 GNO1 GNG1 1–40 1.2–3.6 100 GNO3 GNG3 1.5–75 2.2–6.6 240 GNO4 GNG4 3–150 4.2–13.2 475 GNO5 GNG5 5–250 7.4–33.6 750 GNO6 GNG6 13–425 13–37.2 850 GPO1 GPG1 20–675 19–58.8 2000 GPO2 GPG2 Piston Actuated – #440 Stainless Steel Piston. ® ® 9012GNO5 #303 Stainless Steel Housing, Viton Fluorocarbon Diaphragm and O-Ring, Teflon Retaining Ring. 20–1000 49–150 10000 GQO1 GQG1 90–2900 141–455 15000 GQO2 GQG2 170–5600 200–950 20000 GQO3 GQG3 270–9000 350–1400 25000 GQO4 GQG4 Specifications Fluids Controlled Air, water, hydraulic oils, gases, steam (depending on the model) Pressure Connection G1/4 (BSP) female, 1/4" NPTF, or 1/2”-14 NPT Weight (approximate) Type 1: 2 lb (0.91 kg); Open: 1.7 lb (0.77) Voltage Limits 600 V Continuous Current 10 A Electrical Connections 1/2” conduit entry, unthreaded Standards/Ratings CE, IEC 60957.5.1, UL 508, CSA 3211-03 Temperature Ratings Minimum Maximum Ambient –23 °C (–10 °F) +85 °C (+185 °F) Diaphragm –40 °C (–40 °F) 9012GQO2 Media Piston –26 °C (–15 °F) +120 °C (+250 °F) All with Form Q4 –26 °C (–15 °F) Operating Curves Contact Blocks Acceptable Wire Sizes: Adjustable 12–22 AWG Differential SPDT form C contacts Recommended Terminal Clamp Torque: 7 lb-in Falling pressure (1) Determines the operating point on rising pressure. Table 83: Available Modifications for 9012G Open Type or NEMA Type 1 Enclosure UL Listed and CSA Certified as Industrial Control Equipment 9012GNG1 Modification Applies to Form Standard Buna-N Nitrile diaphragm in #316 stainless steel GNG, GNO, GPG, GPO, GRG, GRO, GSG, GSO Q1 housing Not available on GNG, GNO, GRG, GRO1. Available on Ethylene propylene diaphragm in #316 stainless steel housing Q3 all other GNG, GNO, GPG, GPO, GRG, GRO, GSG, GSO ® Viton fluorocarbon diaphragm in #316 stainless steel housing GNG, GNO, GPG, GPO, GRG, GRO, GSG, GSO Q4 ¼-18 NPT external thread pressure connection GNG, GNO, GRG, GRO Z ½-14 NPT external thread, ¼-18 NPTF internal thread GNG, GNO, GRG, GRO Z16 pressure connection. Standard actuator only. GNG, GNO, GPG, GPO, GQG, GQO, GRG, GRO, GSG, 7 ⁄ -20 UNF-2B internal thread pressure connection Z18 16 GSO, GTG, GTO 93 © 1998–2009 Schneider Electric 10/2009 All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Min. Differential Max. Differential Rising Pressure 4 8 3 4 3 7 2 6 1 2 1 5 Selection and Specifications Industrial Pressure Switches 9016G Vacuum Switches 9016G Vacuum Switches 9016GAW Switches for Sensitive Control Applications 9016GAW vacuum switches have double throw contacts. Normally open and normally closed circuits allow the use of these controls for standard or reverse action applications. Standard controls can be mounted from the front using the bracket provided. Two mounting screws are required for firm attachment to any smooth, flat surface. Allowance must be made for flange projection. Controls with the Form F modification include two mounting feet with 9/32" mounting holes on 3–3/4 in. centers. The Range and Differential adjustments are accessed by removing the front cover. Maximum allowable positive pressure: 100 psig. Diaphragms are oil resisting, nitrile butadiene rubber (Buna-N). For electrical ratings and temperature limitations, see Table 68 on page 83. For dimensions and modifications, see page 99. 9016GAW2 Table 84: 9016GAW Vacuum Switch for Control Applications, Diaphragm Actuated Adjustable Differential Class 9016 Type Range on Decreasing Contact Pipe Tap (1) Adds to Range (inHg) NEMA Enclosure Type Vacuum (inHg) Arrangement (NPTF) @ Minimum Range @ Mid-Range 4, 4X & 13 Type 7 & 9 0–28.7 0.8–9 1.3–7.4 1 N.O.–1 N.C. ¼-18 GAW1 GAR1 0–25 5–20 1 N.O.–1 N.C. ¼-18 GAW2 N/A 0–28.3 1–9 1.7–7.4 2 N.O.–2 N.C. ¼-18 GAW21 GAR21 0–25 5–20 2 N.O.–2 N.C. ¼-18 GAW22 N/A Specifications Fluids Controlled Air, water, hydraulic oils, gases, steam (depending on the model) Pressure Connection G1/4 (BSP) female, 1/4" NPTF, or 1/2”-14 NPT Weight (approximate) Type 4, 4X, and 13: 3 lb (1.36 kg); Type 7 & 9: 10 lb (4.54 kg) Voltage Limits 600 V Continuous Current 10 A Electrical Connections 1/2”-14 NPTF, PG13.5, or ISO M20 (also 3/4”-14 NPTF on NEMA 7 & 9 only) Standards/Ratings CE, IEC 60957.5.1, UL 508, CSA 3211-03 9016GAR1 Temperature Ratings Minimum Maximum Ambient –23 °C (–10 °F) +85 °C (+185 °F) Diaphragm –40 °C (–40 °F) Media Piston –26 °C (–15 °F) +120 °C (+250 °F) All with Form Q4 –26 °C (–15 °F) Operating Curves Contact Blocks Connection Form H17 Brown 1 N.O., Same Adjustable 1N.C. Polarity White Differential Red 4 8 2 1 34 LED 2 6 Black 2 N.O., Same Polarity Black Blue 2N.C. 1 Same Polarity Form H10 Form H11 Falling pressure SPDT snap switches contain two double-break contact elements ORG ORG WHT RED (1 N.O., 1 N.C.) that must be used on circuits of the same polarity. GRN GRN 4 8 4 8 BLK DPDT snap switch contain two electrically separated sets of contact 3 3 4 2 4 2 BLK 26 elements allowing use on circuits of opposite polarity. Each set 26 5 1 5 1 contains two double-break contact elements (1 N.O., 1 N.C.) that 1 1 RED WHT must be used on circuits of the same polarity. Acceptable Wire Sizes: 12–22 AWG Recommended Terminal Clamp Torque: 7 lb-in (1) Add the Differential to the Range to obtain the operating point on increasing vacuum (within vacuum limitations). The differential increases linearly over the range. The minimum differential doubles with NEMA Type 7 & 9 enclosures. File LR 25490 File LR26817 File E12443 Haz Loc CCN NOWT (GAR) Class 3211 06 Type GAR only File E12158 CCN NKPZ (GAW) Type GAW only (NEMA 7 and 9 Haz. Loc.) File E12158 CCN NTHT Marine Use (GAW) 94 10/2009 © 1998–2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Min. Differential Max. Differential Rising Pressure L2 T2 L1 T1 Selection and Specifications Industrial Pressure Switches 9016G Vacuum Switches 9016GVG Power Switches The 9016GVG1 is designed as a companion to the 9036GG float switches in common use on vacuum heating pumps. Electrical ratings of float and vacuum switch types are equal. For dimensions and modifications, see page 99. Table 85: 9016GVG Vacuum Switch for Power Applications NEMA Type 1 Enclosure Contacts Open on Increasing Vacuum 9016GVG1J10 Cut-Out Approximate Cut-In Pressure Vacuum Setting, NEMA Type 1 Encl. Range, Adjustable Differential, Range, Poles Connection inHg Class 9016 Type inHg inHg inHg 3–8 GVG1J09 16.5–25 GVG1J10 17–22 GVG1J11 18–23 GVG1J12 5–25 5–10 In. Hg. 0–20 2 ¼-18 NPSF 20–25 GVG1J13 Specify other vacuum (minimum order quantity: GVG1J99 4 pieces) Specifications Fluids Controlled Air, water, hydraulic oils, gases, steam (depending on the model) Pressure Connection G1/4 (BSP) female, 1/4" NPTF, or 1/2”-14 NPT Weight (approximate) 2 lb (0.91) Voltage Limits 600 V Continuous Current 10 A Electrical Connections 1/4"-18 NPTF or 1/2"-14 NPT Standards/Ratings CE, IEC 60957.5.1, UL 508, CSA 3211-03 Temperature Ratings Minimum Maximum Ambient –23 °C (–10 °F) +85 °C (+185 °F) Diaphragm –40 °C (–40 °F) Media Piston –26 °C (–15 °F) +120 °C (+250 °F) All with Form Q4 –26 °C (–15 °F) Operating Curves Contact Blocks Adjustable Acceptable Wire Sizes: Differential DPST 8–14 AWG Recommended Terminal Clamp Torque: 22-27 lb-in Falling pressure For other ratings and specifications, see page 83. File CCN File E12158 NKPZ LR 25490 95 © 1998–2009 Schneider Electric 10/2009 All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Min. Differential Max. Differential Rising Pressure 9012G Dimensions Industrial Pressure Switches Dimensions Dimensions Figure 2: Types GAW, GDW, GKW 1, 21 Machine Tool Pressure Switch Dimensions X: Conduit connection: G•W = 1/2-14 NPT; G•WM = 20MMBGS4568, Form M12 = Pg13.5; DIN40430. Y: Pressure connection: G•W = 1/4-18 NPTF; G•WM = 8; Form M14 = G 1/4 BS 2779; RP1/4 ISO 711; R 1/4 DIN 2999; GJ 1/4 UN1339. Figure 3: 9012 GAW, GBW, GCW, GDW, GEW, GFW, GKW, GLW, and GMW Machine Tool Pressure Switch Dimensions (except GAW, GDW, GKW 1, 21) 3.50 89 Form K 1.13 2.63 29 0.88 2.72 67 22 0.48 69 12 0.38 2.30 10 0.40 0.48 58 Form K1 10 12 0.17 4 Forms 3.60 E1, E2, E3, E4 91 0.27 7 2.72 (2) dia. 69 Mtg. Holes Forms G17, G18, G19, G20, G21, G22, & T4 0.38 10 A 1/2-14 NPT Conduit Electrical Connection 1/4-18 NPTF 1.22 0.58 1.61 in. Pipe Thread Dual Dimensions: 31 15 41 mm Pressure Connection Type Dimension A, in. (mm) GAW, GDW, GKW 2, 4, 5, 6, 22, 24, 25, 26 2.33 (59) GBW, GEW, GLW 1, 2, 21 2.23 (57) GCW, GFW, GMW 1, 2, 3, 4, 21, 22, 23, 24 3.15 (80) NOTE: Dimensions change with metric thread. For flange and mounting bracket dimensions for low pressure device, see Figure 10. 96 10/2009 © 1998–2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 9012G Dimensions Industrial Pressure Switches Dimensions Figure 4: Types GGW, GHW, GJW GGW1, 21 GGW4, 24 5.05 Section A–A 128 3.50 1.44 2.31 Bolt or Screw 1/4 89 1.67 59 37 4.38 2.72 42 Ø X 111 X 69 1.89 7.98 A 0.47 Max. Head Ø 48 203 12 1.31 7.52 M A 2.72 33 0.28 7.08 (4) Ø 195 69 7 180 0.27 3.76 M (2) Ø 7 96 2.47 B 0.28 (3)Ø Y 63 2.63 Turn Radius 7 67 C 2.37 0.50 1.25 Y 1.25 1.61 1.22 C 60 32 13 32 Turn Radius 41 32 2.86 B 3.63 2.71 2.63 73 69 92 67 GJW1, 21 GHW1, 21 3.50 3.50 Section A–A Section A–A 89 Bolt or Screw 89 1/4 Bolt or Screw 1/4 2.72 1.67 1.67 2.72 X 69 42 69 42 X 1.73 2.63 A 44 0.47 Max. 67 A 0.47 Ø Max Ø 12 Head 12 Head A Mounting Detail 2.72 6.76 A 69 2.72 172 7.08 69 180 0.27 M (2) Ø 7 0.27 2.31 M (2)Ø Y 7 59 Turn Radius 3.20 2.63 Y 67 Turn Radius 1.22 81 2.63 1.61 B C 32 67 41 2.63 67 1.22 in. C Dim. = 32 1.61 B 2.63 mm 41 67 Figure 5: Types GAR, GBR, GCR, GDR, GER, and GFR Table 86: Dimension A for G•R Switches Type Dimension A, in. (mm) in. GAR1, 2, 21, 22 2.02 (56) Dim. = 4.95 mm Cover Removal Clearance GAR4, 5, 6, 24, 25, 26 1.42 (36) 126 GBR1, 2, 21, 22; GCR1, 21 1.32 (34) GCR2, 3, 4, 22, 23, 24 2.24 (57) GDR1, 2, 21, 22 2.02 (56) GDR4, 5, 6, 24, 25, 26 1.42 (36) 5.78 GER1, 2, 21, 22; GFR1, 21 1.32 (34) 147 GFR2, 3, 4, 22, 23, 24 2.24 (57) M M 3/4-14 NPT A 0.41 10 3.69 2.91 2.34 94 74 59 5.88 4.90 Turn Radius 149 125 97 © 1998–2009 Schneider Electric 10/2009 All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 9012G Dimensions Industrial Pressure Switches Dimensions Figure 6: Types GNO1, GRO1 Figure 7: Types GNG1, GRG1 Figure 8: Types GNO, GRO Figure 9: Types GNG, GPG, GQG, GRG, GSG, and GTG 1.62 Hole for 41 1/2 Conduit .82 0.20 Dia. 21 5 Mounting 0.58 0.22 x 1.38 Holes (2) 15 6 4.00 35 3.59 4.13 102 2 91 105 5.03 mounting 5.53 128 slots 1.60 3.22 140 41 82 1.60 41 A A 1.03 1.17 1.03 1.11 26 2.21 30 2.06 1/4-18 NPTF 26 1/4 - 18 28 2.75 56 2.46 2.06 52 internal thread NPTF 70 63 52 in. Dim. = internal thread mm Table 87: Dimension A for G•O Switches Table 88: Dimension A for G•G Switches Type Dimension A, in. (mm) Type Dimension A, in. (mm) GNO, GRO 3, 4, 5, 6 1.41 (36) GNG, GRG 3, 4, 5, 6 1.41 (36) GPO, GSO 1, 2, 3 1.31 (33) GPG, GSG 1, 2, 3 1.31 (33) GQO, GTO 1, 2, 3, 4 2.24 (57) GQG, GTG 1, 2, 3, 4 2.24 (57) 98 10/2009 © 1998–2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 9016G Dimensions Industrial Pressure Switches Dimensions Figure 10: 9016GAW Control Vacuum Switch Dimensions Table 89: Available Modifications for 9016GAW Vacuum Switches Description Form Mounting feet (GAW 1, 21 only) F ® Viton diaphragm with #316 stainless steel flange Q4 Range scale window ((standard with Forms K and K1) V1 Special setting specified Y1 (If indicating only one special setting, specify whether this setting is on increasing or decreasing pressure.) ¼-18 NPT external thread pressure connection Z ½-14 NPT external thread, ¼-18 NPTF internal thread pressure connection (standard actuator only) Z16 Figure 11: 9016GVG Power Vacuum Switch Dimensions 3.88 3.44 99 1.94 87 49 Three 0.88 in. (22 mm) 3.81 knockouts for 0.5 inch conduit 97 7.13 181 1.06 4 3.88 27 3.8 102 3.06 98 97 78 1.25 1.25 1.09 0.47 28 32 32 12 2.31 0.28 in. (7 mm) 59 2.38 diameter holes 4.38 Diameter 60 111 Table 90: Available Modifications for 9016GVG Vacuum Switches Description Form 3-way lever plus nameplate with marking: Float only—Vacuum and Float—Continuous E (factory modification only) Mounting bracket (for retrofit, order 9049A53 bracket kit) F Reverse action, normally open contacts R ¼ in. male pipe connection (¼"-18 NPT, external thread) (for retrofit, use ¼" pipe nipple) Z 99 © 1998–2009 Schneider Electric 10/2009 All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 9016G Dimensions Industrial Pressure Switches Dimensions 100 10/2009 © 1998–2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Industrial Pressure Switches Index Index Numerics M 9012 modifications accessories 91 9012 91 application 79 9016 99 dimensions 96 O interpreting the catalog number 84 introduction 79 operating curves, XML 16 modifications 91 operating principle, XML parts 91 pressure switch 12 selection 85–93 vaccum switch 13 selection guide 5 P specifications 83 9016 parts application 79 9012 91 dimensions 99 XML 73 interpreting the catalog number 84 pressure switches, 9012G, see 9012 introduction 79 pressure switches, XML, see XML modifications 99 S selection 94–95 selection guide 5 selecting a pressure switch 8 specifications 83 selection 9012 85–93 A 9016 94–95 accessories XML 21–72 9012 91 selection guide XML 73 9012 5 9016 5 C XML 4 catalog number interpretion specifications 9012 84 9012 83 9016 84 9016 83 XML 20 XML 11 component materials in contact with fluid 77 T converting units of pressure 15 terminology 6 D V definitions 6 dimensions vacuum switches, 9016G, see 9016 9012 96 vacuum switches, XML, see XML 9016 99 X XML 74 XML G accessories 73 glossary 6 component materials in contact with fluid 77 dimensions 74 I interpreting the catalog number 20 interpreting the catalog number introduction 10 9012 84 operating curves 16 9016 84 operating principle, pressure switch 12 XML 20 operating principle, vaccum switch 13 introduction parts 73 9012 79 selection 21–72 9016 79 selection guide 4 XML 10 specifications 11 101 10/2009 © 1998–2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com ® ® Schneider Electric USA Square D and Schneider Electric are trademarks or registered trademarks of 8001 Knightdale Blvd. Schneider Electric or its affiliates. Other trademarks used herein are the property of Knightdale, NC 27545 their respective owners. 1-888-Square D 1-888-778-2733 9012CT9701R04/09 © 1998–2009 Schneider Electric All Rights Reserved www.schneider-electric.us Replaces 9012CT9701 dated May 1998 10/2009 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Frequently asked questions
What makes Elite.Parts unique?
What kind of warranty will the XML-A300D2S11 have?
Which carriers does Elite.Parts work with?
Will Elite.Parts sell to me even though I live outside the USA?
I have a preferred payment method. Will Elite.Parts accept it?
Why buy from GID?
Quality
We are industry veterans who take pride in our work
Protection
Avoid the dangers of risky trading in the gray market
Access
Our network of suppliers is ready and at your disposal
Savings
Maintain legacy systems to prevent costly downtime
Speed
Time is of the essence, and we are respectful of yours
Related Products
Schneider Electric XENL1111 Pushbutton Contact, Spring Return Contact Block, 1 N/O, Rear Box Mountin...
Manufacturers





What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods