GEMS SENSORS ST-22445

Image of GEMS SENSORS ST-22445

Description

GEMs Sensors ST22445 - Safe Pak, Switch

Part Number

ST-22445

Price

Request Quote

Manufacturer

GEMS SENSORS

Lead Time

Request Quote

Category

PRODUCTS - S

Specifications

Amperage

5A

Rating

95-135 VAC

Datasheet

pdf file

ST22445-d-1156858505s.pdf

521 KiB

Extracted Text

Example (Cont.) SAFE-PAK Models 22445, 25872, 25873 Because of the low sensitivity of the device, maximum lead length is limited to a total switch Latching SAFE-PAK Models 41705, 41715 lead resistance of 200 ohms. HI-LO PAK Models 38705, 38710, 38715, 38720 GROUP CAPACITANCE INDUCTANCE A & B 1 uf .50 mh Instruction Bulletin No. 54477 C 1 uf .50 mh D 1 uf .50 mh For use as an "intrinsically safe switch circuit" and in hazardous locations with non- voltage producing sensors. When SAFE-PAK installation is in accordance with this guide, D. Whenever possible, the actual measured parameters should be used in making these field sensors are suitable for Class I; Divisions 1, 2; Groups A, B, C and D and Class the determination of allowable length. II; Division 2; Groups E, F and G, as defined by Article 500 of the National Electric Code. E. Shielded cable is not required; but if used in the application, the shield must be returned to ground - the same as the PAK mounting bracket. IMPORTANT! Read carefully and completely before installing or connecting SAFE- F. Non-intrinsically safe wiring cannot be run in conduit or open raceways together PAK, Latching SAFE-PAK or HI-LO PAK units. with intrinsically safe wiring. *** Warning: To prevent ignition of flammable or combustible atmospheres, disconnect G. Refer to Fig. 8 for detailed connection to terminal studs. All hardware, including power before servicing. terminal lugs, is supplied with unit. H. Fusing of the SAFE-PAK to be in accordance with Fig. 1. Fuse F1 to be 6 amps 1. Associated Equipment - Caution: The SAFE-PAK must be mounted outside the "slo-blo". 120 VAC for 120 V line voltage; 250 VAC for 240 volts. hazardous area. Only the switch or sensor terminals provide an intrinsically safe I. Protective cover (supplied) must be in place over sensor-connected terminals of switch circuit (see Fig. 1, Fig. 2, Fig 3 or Fig. 4). [Exia] means associated equipment: the PAK after wiring has been completed (See Fig. 9) "Appareillage connexe", located in safe area. Fig. 1. Fig. 8 Connection Diagram: Gems SAFE-PAK Models Recommended Method of Connection to Electrical Terminals FUSE F1 Terminal Lug. Input HEX (Closed-Ring Type) LOAD Nut Note VAC Terminal Stud Anti-Vibrational For 120V application, FUSE F1 Lockwasher [Exia] only one fuse is required in the ungrounded circuit SAFE-PAK Notes Tighten Assembly to Between of the input line. Non-Hazardous 3 and 5 In. Lbs. Location All terminal hardware (including lug) supplied with unit. Hazardous Location Fig. 9 Mounting of Protective Cover over Sensor-Connected Terminals of Unit Sensor Switch Stud Fig. 2. Stud Cover Cover Circuit for Pump-Down Operation Nylon Nylon Stud Nuts Stud Nuts Terminals Non-Hazardous Hazardous Terminals Location Location (High) Fuse F1 N.O. Dry VAC (Hot) On A C S2 LATCHING SAFE-PAK SAFE-PAK Com Com L O A D Off Load Latching (Low) SAFE-PAK S1 N.O. Dry P/N 54477 Rev. AE Fig. 5 Fig. 3 Multiple PAK Units Grouped on Common Earth-Grounded Mounting Plate Circuit for Pump-Up Operation Non-Intrinsically Earth Ground Safe Wiring (2 Places) Non-Hazardous Hazardous Location Location Common (Low) Earth-Grounded Fuse F1 N.C. Dry Mounting Plate PAK Units VAC (Hot) On A C S1 Com Com L O A D Off Load (High) S2 N.C. Dry Latching Resistance to ground SAFE-PAK must be from bracket to earthing member to insure Intrinsically Safe integrity of system (must Wiring To Sensors be below one ohm). Fig. 4 Note: All intrinsically safe wiring must be segregated from non-intrinsically safe Circuit for HI-LO PAK Operation wiring and shall have a minimum insulation thickness of .010". AC LOAD Fig. 6 Fig. 7 Unit Mounting Detail Mounting Plate Grounding Detail AC LOAD SAFE-PAK GEMS Screw  HI-LO PAK Mounting *Lockwasher Plate #10 Screw HI COM LO Non-Hazardous Area *#10 Lockwasher Terminal Lug Hazardous Area *Lockwasher Nut *#10 Lockwasher Mounting Plate HI LO #10 Nut Notes 1. Grounding Hardware to be #8 or larger and Stainless Steel. COM Note 2. *Lockwashers to be internal or external tooth type. 1. *Lockwashers to be internal or external tooth type. Probes in Container or Tank 3. Installation of Sensor Switch and Running of Field Wiring 2. Mounting and Enclosure Considerations A. Field wiring of intrinsically safe circuits is to be segregated from non-intrinsically safe B. The conductors of the intrinsically safe circuit should be sealed in a rigid metal wiring by use of suitable barriers, separate wireways or trays (See Fig. 5). Wire conduit at the point where the wiring enters the hazardous area. The wiring and insulation to be .010" minimum. contacting device should be such that conductive dusts in the area will not close the B. Intrinsically safe and non-intrinsically safe connection points should be located circuit in place of the contacts. sufficiently apart to prevent any possibility of bypassing or miswiring during installation or servicing of equipment. C. Hazardous area field wiring will store energy due to distributed capacitance and C. The enclosure shall contain a cautionary statement as follows: "CAUTION: ANY SUBSTITUTION OF COMPONENTS MAY IMPAIR INTRINSIC SAFETY". inductance in proportion to its length. It is therefore recommended that the characteristics D. The PAK mounting bracket must be grounded to insure intrinsic safety. (available from the manufacturer) of the cable be known and judged against the length of Resistance between bracket and ground electrode should be below one ohm. run and atmosphere of exposure. The following conservative chart is presented as a (See Fig. 6 and Fig. 7 for recommended selection of grounding hardware and guideline in determining the limits of reactance for signal loops in the hazardous area refer to Article 250 of the National Electrical Code for methods and practices.) wiring for the SAFE-PAK series. 3. Installation of Sensor Switch and Running of Field Wiring Example: Typical values of capacitance for a twisted pair of copper wires is between A. The nature of the sensor switch must be that it is a non-voltage-producing, essen- 20 and 60 pf per foot. Inductance of a typical twisted pair is between 0.10 and 0.20 tially resistive device, containing no energy-storing components. uh/ft., thus making a cable run in this example essentially determined by the inductance.

Frequently asked questions

What makes Elite.Parts unique?

chervon down
At GID Industrial (Elite.Parts' parent company), we specialize in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

What kind of warranty will the ST-22445 have?

chervon down
Warranties differ by part and by which suppliers we use to procure it for you. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carriers does Elite.Parts work with?

chervon down
Elite.Parts can ship via FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Will Elite.Parts sell to me even though I live outside the USA?

chervon down
Absolutely! We are happy to serve customers regardless of location. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

I have a preferred payment method. Will Elite.Parts accept it?

chervon down
All major credit cards are accepted: Visa, MasterCard, Discover, and American Express. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

Gems Sensors SAFE-PAK Series Switch | Intrinsically Safety Switches

Gems Sensors | Sensors

GEMS Sensors Sensors/Indicators

GEMS Sensors Series M Level Sensors | Tilt Float Switch

GEMS Sensors Shuttle Switches

RELAY SOLID STATE LOAD-PAK 120/240VAC 5A SPST