FLUKE FLUKE-87-5-EX
Features
- Auto and Manual Ranging for Maximum Flexibility
- Complies with Second Edition IEC and ANSI Electrical Safety Standards
- Improved Sleep Mode for Long Battery Life
- Meets 1000V CAT III and 600V CAT IV Safety Standards (IEC 1010-1)
- Recommended accessories: C35 Case, TLK-220 Test Lead Set, i400 Current Clamp
- Relative Mode to Remove Test Lead Resistance for Low Ohms Measurements
- UL listed, CSA certified, CE compliant, VDE approved, TUV approved
Datasheet
Extracted Text
Fluke 83V and 87V Digital Multimeters Detailed Specifications For all detailed specifications: Accuracy is given as ±([% of reading] + [number of least significant digits]) at 18 °C to 28 °C, with relative humidity up to 90 %, for a period of one year after calibration. 1 For Model 87 in the 4 ⁄2-digit mode, multiply the number of least significant digits (counts) by 10. AC conversions are ac-coupled and valid from 3 % to 100 % of range. Model 87 is true-rms responding. AC crest factor can be up to 3 at full scale, 6 at half scale. For non-sinusoidal wave forms add -(2 % Rdg + 2 % full scale) typical, for a crest factor up to 3. Fluke 87V ac voltage function specifications (true-rms) Accuracy 1 Function Range Resolution 45 - 65 Hz 30 - 200 Hz 200 - 440 Hz 440 Hz - 1 kHz 1 - 5 kHz 5 - 20 kHz 2,4 600.0 mV 0.1 mV ± (0.7 % + 4) ± (2.0 % + 4) ± (2.0 % + 20) 6.000 V 0.001 V ± (1.0 % + 4) 3 60.00 V 0.01 V ± (0.7 % + 2) ± (2.0 % + 4) unspecified 600.0 V 0.1 V 1000 V 1 V unspecified unspecified Using low pass filter ± (0.7 % + 2) ± (1.0 % + 4) + 1 % + 4 unspecified unspecified unspecified 5 -6 % - 4 1 Below 10 % of range, add 6 counts. 2 The Fluke 87V is a true-rms responding meter. When the input leads are shorted together in the ac functions, the meter may display a residual reading between 1 and 30 counts. A 30-count residual reading will cause only a 2-digit change for readings over 3 % of range. Using REL to offset this reading may produce a much larger constant error in later measurements. 3 Frequency range: 1 kHz to 2.5 kHz. 4 A residual reading of up to 13 digits with leads shorted, will not affect stated accuracy above 3 % of range. 5 Specification increases from -1 % at 200 Hz to -6 % at 440 Hz when filter is in use. Fluke 83V ac voltage function specifications (average responding rms indicating) Accuracy Function Range Resolution 50 Hz - 60 Hz 30 Hz - 1 kHz 1 kHz - 5 kHz 1 600.0 mV 0.1 mV ± (0.5 % + 4) ± (1.0 % + 4) ± (2.0 % + 4) 6.000 V 0.001 V ± (0.5 % + 2) ± (1.0 % + 4) ± (2.0 % + 4) 60.00 V 0.01 V ± (0.5 % + 2) ± (1.0 % + 4) ± (2.0 % + 4) 2 600.0 V 0.1 V ± (0.5 % + 2) ± (1.0 % + 4) ± (2.0 % + 4) 1000 V 1 V ± (0.5 % + 2) ± (1.0 % + 4) unspecified 1 Below a reading of 200 counts, add 10 counts 2 Frequency range: 1 kHz to 2.5 kHz Fluke 83V and 87V Detailed Specifications cont. DC voltage, resistance, and conductance function Temperature specifications specifications (87V only) 1, 2 Accuracy Temperature Resolution Accuracy Function Range Resolution Fluke 83V Fluke 87V -200 °C to +1090 °C 0.1 °C 1 % + 10 6.000 V 0.001 V ± (0.1 % + 1) ± (0.05 % + 1) -328 °F to +1994 °F 0.1 °F 1 % + 18 60.00 V 0.01 V ± (0.1 % + 1) ± (0.05 % + 1) 1 Does not include error of the thermocouple probe. 600.0 V 0.1 V ± (0.1 % + 1) ± (0.05 % + 1) 2 Accuracy specification assumes ambient temperature stable to ± 1 °C. 1000 V 1 V ± (0.1 % + 1) ± (0.05 % + 1) For ambient temperature changes of ± 5 °C, rated accuracy applies after 1 hour. 600.0 mV 0.1 mV ± (0.3 % + 1) ± (0.1 % + 1) 1 1 600.0 Ω 0.1 Ω ± (0.4 % + 2) ± (0.2 % + 2) 6.000 kΩ 0.001 kΩ ± (0.4 % + 1) ± (0.2 % + 1) 60.00 kΩ 0.01 kΩ ± (0.4 % + 1) ± (0.2 % + 1) 600.0 kΩ 0.1 kΩ ± (0.7 % + 1) ± (0.6 % + 1) 6.000 MΩ 0.001 MΩ ± (0.7 % + 1) ± (0.6 % + 1) 2 2 50.00 MΩ 0.01 MΩ ± (1.0 % + 3) ± (1.0 % + 3) 1 1 nS 60.00 nS 0.01 nS ± (1.0 % + 10) ± (1.0 % + 10) 1 When using the REL Δ function to compensate for offsets 2 Add 0.5 % of reading when measuring above 30 MΩ in the 50 MΩ range and 20 counts below 33 nS in the 60 nS range Current function specifications Accuracy Burden Voltage 1 2, 3 Function Range Resolution Model 83 Model 87 (typical) 5 60.00 mA 0.01 mA ± (1.2 % + 2) ± (1.0 % + 2) 1.8 mV/mA 6 5 400.0 mA 0.1 mA ± (1.2 % + 2) ± (1.0 % + 2) 1.8 mV/mA 5 6.000 A 0.001 A ± (1.2 % + 2) ± (1.0 % + 2) 0.03 V/A 4 5 (45 Hz to 2 kHz) 10.00 A 0.01 A ± (1.2 % + 2) ± (1.0 % + 2) 0.03 V/A 60.00 mA 0.01 mA ± (0.4 % + 4) ± (0.2 % + 4) 1.8 mV/mA 6 400.0 mA 0.1 mA ± (0.4 % + 2) ± (0.2 % + 2) 1.8 mV/mA 6.000 A 0.001 A ± (0.4 % + 4) ± (0.2 % + 4) 0.03 V/A 4 10.00 A 0.01 A ± (0.4 % + 2) ± (0.2 % + 2) 0.03 V/A 5 600.0 μA 0.1 μA ± (1.2 % + 2) ± (1.0 % + 2) 100 μV/μA 5 6000 μA 1 μA ± (1.2 % + 2) ± (1.0 % + 2) 100 μV/μA (45 Hz to 2 kHz) 600.0 μA 0.1 μA ± (0.4 % + 4) ± (0.2 % + 4) 100 μV/μA 6000 μA 1 μA ± (0.4 % + 2) ± (0.2 % + 2) 100 μV/μA 1 AC conversion for Model 83 is ac coupled and calibrated to the rms value of a sine wave input. 2 AC conversions for Model 87 are ac coupled, true rms responding, and valid from 3 % to 100 % of range. 3 Model 87 is a true rms responding meter. When the input leads are shorted together in the ac functions, the Meter may display a residual reading between 1 and 30 counts. A 30 count residual reading will cause only a 2 digit change for readings over 3 % of range. Using REL to offset this reading may produce a much larger constant error in later measurements. 4 10 A continuous up to 35 °C; < 20 minutes on, 5 minutes off at 35 °C to 55 °C. 20 A for 30 seconds maximum; > 10 A unspecified. 5 Below a reading of 200 counts, add 10 counts. 6 400 mA continuous; 600 mA for 18 hours maximum. Capacitance and diode function specifications Function Range Resolution Accuracy 1 10.00 nF 0.01 nF ± (1 % + 2) 1 100.0 nF 0. 1 nF ± (1 % + 2) 1.000 μF 0.001 μF ± (1 % + 2) 10.00 μF 0.01 μF ± (1 % + 2) 100.0 μF 0.1 μF ± (1 % + 2) 9999 μF 1 μF ± (1 % + 2) 3.000 V 0.001 V ± (2 % + 1) 1 With a film capacitor or better, using Relative mode to zero residual. 2 Fluke Corporation Fluke 83V and 87V detailed specifications Frequency counter specifications Function Range Resolution Accuracy Frequency 199.99 0.01 Hz ± (0.005 % + 1) (0.5 Hz to 200 kHz, 1999.9 0.1 Hz ± (0.005 % + 1) pulse width > 2 μs) 19.999 kHz 0.001 kHz ± (0.005 % + 1) 199.99 kHz 0.01 kHz ± (0.005 % + 1) > 200 kHz 0.1 kHz unspecified Frequency counter sensitivity and trigger levels Minimum Sensitivity (RMS Sine wave) Approximate Trigger Level 1 Input Range 5 Hz - 20 kHz 0.5 Hz - 200 kHz (DC Voltage Function) 600 mV dc 70 mV (to 400 Hz) 70 mV (to 400 Hz) 40 mV 600 mV ac 150 mV 150 mV — 6 V 0.3 V 0.7 V 1.7 V 60 V 3 V 7 V (≤ 140 kHz) 4 V 600 V 30 V 70 V (≤ 14.0 kHz) 40 V 1000 V 100 V 700 V (≤ 1.4 kHz) 100 V Duty Cycle Range Accuracy 0.0 to 99.9 % Within ± (0.2 % per kHz + 0.1 %) for risetimes < 1 μs 1 Maximum input for specified accuracy = 10X Range or 1000 V. Electrical characteristics of the terminals Function Overload Input Impedance Common Mode Rejection Ratio 1 Protection (nominal) (1 kΩ unbalance) Normal Mode Rejection 1000 V rms 10 MΩΩ < 100 pF > 120 dB at dc, 50 Hz or 60 Hz > 60 dB at 50 Hz or 60 Hz 1000 V rms 10 MΩΩ < 100 pF >120 dB at dc, 50 Hz or 60 Hz > 60 dB at 50 Hz or 60 Hz 1000 V rms 10 MΩΩ < 100 pF > 60 dB, dc to 60 Hz (ac-coupled) Full Scale Voltage Typical Short Circuit Current Open Circuit Test Voltage To 6.0 MΩ 50 MΩ or 60 nS 600 Ω 6 k 60 k 600 k 6 MΩ 50 MΩ 1000 V rms < 7.3 V dc < 4.1 V dc < 4.5 V dc 1 mA 100 μA 10 μA 1μA 1 μA 0.5 μA 1000 V rms < 3.9 V dc 3.000 V dc 0.6 mA typical 6 1 10 V Hz maximum MIN MAX recording specifications Model Nominal Response Accuracy 83V 100 ms to 80 % Specified accuracy ± 12 counts for changes > 200 ms in duration (± 40 counts in ac with beeper on) 87V 100 ms to 80 % Specified accuracy ± 12 counts for changes > 200 ms in duration (dc functions) > 25 % of range 120 ms to 80 % Specified accuracy ± 40 counts for changes > 350 ms and inputs (ac functions) 250 μs (peak) Specified accuracy ± 100 counts for changes > 250 μs in duration 1 (Model 87 only) (add ± 100 counts for readings over 6000 counts) (add ± 100 counts for readings in Low Pass mode) 1 For repetitive peaks: 1 ms for single events. Fluke 83V and 87V detailed specifications Fluke Corporation 3 Fluke 83V and 87V General Specifications Maximum voltage between any terminal and earth ground: 1000 V rms Fuse protection for mA or μA inputs: 44/100 A, 1000 V FAST Fuse Fuse protection for A input: 11 A, 1000 V FAST Fuse Display: Digital: 6000 counts updates 4/sec; (Model 87V also has 19,999 counts in high-resolution mode) Analog: 33 segments, updates 40/sec. Frequency: 19,999 counts, updates 3/sec at > 10 Hz Temperature: Operating: -20 °C to +55 °C; Storage: -40 °C to +60 °C Altitude: Operating: 2000 m Storage: 10,000 m Temperature coefficient: 0.05 x (specified accuracy)/ °C (< 18 °C or > 28 °C) Electromagnetic compatibility: In an RF field of 3 V/m total accuracy = specified accuracy Relative humidity: 0 % to 90 % (0 °C to 35 °C); 0 % to 7 0% (35 °C to 55 °C) Battery type: 9 V zinc, NEDA 1604 or 6F22 or 006P Battery life: 400 hours typical with alkaline (with backlight off) Vibration: Per MIL-PRF-28800 for a Class 2 instrument Shock: 1 Meter drop per IEC 61010-1:2001 Size (HxWxL): 1.25 in x 3.41 in x 7.35 in (3.1 cm x 8.6 cm x 18.6 cm) Size with holster and flex-stand: 2.06 in x 3.86 in x 7.93 in (5.2 cm x 9.8 cm x 20.1 cm) Weight: 12.5 oz (355 g) Weight with holster and flex-stand: 22.0 oz (624 g) Safety: Complies with ANSI/ISA S82.01-2004, CSA 22.2 No. 1010.1:2004 to 1000 V Overvoltage Category III, IEC 664 to 600 V Overvoltage Category IV. UL listed to UL3111-1. Licensed by TÜV to EN61010-1. Fluke.Keeping your world up and running. Fluke Corporation PO Box 9090, Everett, WA USA 98206 Fluke Europe B.V. PO Box 1186, 5602 BD Eindhoven, The Netherlands For more information call: In the U.S.A. (800) 443-5853 or Fax (425) 446-5116 In Europe/M-East/Africa (31 40) 2 675 200 or Fax (31 40) 2 675 222 In Canada (800)-36-FLUKE or Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: http://www.fluke.com/ ©2005 Fluke Corporation. All rights reserved. Printed in U.S.A. 4/2005 2161164 D-US-N Rev B 4 Fluke Corporation Fluke 83V and 87V detailed specifications
Frequently asked questions
What makes Elite.Parts unique?

What kind of warranty will the FLUKE-87-5-EX have?

Which carriers does Elite.Parts work with?

Will Elite.Parts sell to me even though I live outside the USA?

I have a preferred payment method. Will Elite.Parts accept it?

What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods