Elite.Parts Manufacturers D DELTA VFD007S11B
About product Specifications Features Datasheet FAQ

DELTA VFD007S11B

Image of DELTA VFD007S11B

Description

Delta VFD007S11B Drive. 1 HP | VFD-S Variable Speed 115 Volt 1 phase 0.7 kW | AC Motor Variable Frequency Drive

Part Number

VFD007S11B

Price

Request Quote

Manufacturer

DELTA

Lead Time

Request Quote

Category

TBD

Specifications

AC Line Regenerative

No

Amps (CT)

1 Amps

Braking Type

DC Injection;Dynamic Braking

Closed Loop

No

Dynamic Braking Trans

Included

Enclosure Rating

IP20

HP (CT)

1 Horsepower

Input Phase

1

Input Range VAC

100 to 120 Volts AC

Max. Frequency

400 Hertz

Motor Control-Max Level

V/Hz (Scalar)

Nominal Input VAC

120 Volts AC

Operator Controls

Built In

Features

Datasheet

pdf file

Delta Electronics-VFD007S11B-datasheet1-1611954382.pdf

12441 KiB

Extracted Text

Preface Thank you for choosing DELTA’s high-performance VFD-S Series. The VFD-S Series is manufactured with high-quality components and materials and incorporate the latest microprocessor technology available. This manual is to be used for the installation, parameter setting, troubleshooting, and daily maintenance of the AC motor drive. To guarantee safe operation of the equipment, read the following safety guidelines before connecting power to the AC motor drive. Keep this operating manual at hand and distribute to all users for reference. To ensure the safety of operators and equipment, only qualified personnel familiar with AC motor drive are to do installation, start-up and maintenance. Always read this manual thoroughly before using VFD-S series AC Motor Drive, especially the WARNING, DANGER and CAUTION notes. Failure to comply may result in personal injury and equipment damage. If you have any questions, please contact your dealer. PLEASE READ PRIOR TO INSTALLATION FOR SAFETY. DANGER! 1. AC input power must be disconnected before any wiring to the AC motor drive is made. 2. A charge may still remain in the DC-link capacitors with hazardous voltages, even if the power has been turned off. To prevent personal injury, please ensure that power has been turned off before opening the AC motor drive and wait ten minutes for the capacitors to discharge to safe voltage levels. 3. Never reassemble internal components or wiring. 4. The AC motor drive may be destroyed beyond repair if incorrect cables are connected to the input/output terminals. Never connect the AC motor drive output terminals U/T1, V/T2, and W/T3 directly to the AC mains circuit power supply. 5. Ground the VFD-S using the ground terminal. The grounding method must comply with the laws of the country where the AC motor drive is to be installed. Refer to the Basic Wiring Diagram. 6. VFD-S series is used only to control variable speed of 3-phase induction motors, NOT for 1- phase motors or other purpose. 7. VFD-S series shall NOT be used for life support equipment or any life safety situation. WARNING! 1. DO NOT use Hi-pot test for internal components. The semi-conductor used in the AC motor drive is easily damaged by high-pressure. 2. There are highly sensitive MOS components on the printed circuit boards. These components are especially sensitive to static electricity. To prevent damage to these components, do not touch these components or the circuit boards with metal objects or your bare hands. 3. Only qualified personnel are allowed to install, wire and maintain AC motor drive. CAUTION! 1. Some parameter settings will cause the motor to run immediately after applying power. 2. DO NOT install the AC motor drive in a place subjected to high temperature, direct sunlight, high humidity, excessive vibration, corrosive gases or liquids, or airborne dust or metallic particles. 3. Only use AC motor drives within specification. Failure to comply may result in fire, explosion or electric shock. 4. To prevent personal injury, please keep children and unqualified people away from the equipment. 5. When the motor cable between the AC motor drive and motor is too long, the layer insulation of the motor may be damaged. Please use a frequency inverter duty motor or add an AC output reactor to prevent damage to the motor. Refer to appendix B Reactor for details. 6. The rated voltage for the AC motor drive must be ≤ 240V (≤ 480V for 460V models) and the mains supply current capacity must be ≤ 5000A RMS (≤10000A RMS for the ≥ 40hp (30kW) models). Table of Contents Preface ..............................................................................................................i Table of Contents ...........................................................................................iii Chapter 1 Introduction.................................................................................1-1 1.1 Receiving and Inspection.................................................................... 1-1 1.1.1 Nameplate Information................................................................ 1-1 1.1.2 Model Explanation ...................................................................... 1-1 1.1.3 Series Number Explanation ........................................................ 1-2 1.1.4 Drive Frames .............................................................................. 1-2 1.2 Appearances....................................................................................... 1-2 1.3 Installation Steps ................................................................................ 1-3 1.4 Storage ............................................................................................... 1-4 Chapter 2 Installation and Wiring ...............................................................2-1 2.1 Ambient Conditions............................................................................. 2-1 2.2 Installation........................................................................................... 2-1 2.3 Dimensions......................................................................................... 2-3 2.4 Wiring ............................................................................................... 2-16 2.4.1 Basic Wiring.............................................................................. 2-17 2.4.2 External Wiring.......................................................................... 2-21 2.4.3 Main Terminals Connections .................................................... 2-22 2.4.4 Control Terminals...................................................................... 2-24 2.4.5 Main Circuit Terminals .............................................................. 2-28 Chapter 3 Start Up........................................................................................3-1 3.1 Preparations before Start-up............................................................... 3-1 3.2 Operation Method............................................................................... 3-2 3.3 Trial Run ............................................................................................. 3-2 Chapter 4 Digital Keypad Operation ...........................................................4-1 4.1 Description of the Digital Keypad........................................................ 4-1 4.2 Explanation of LED Indicators............................................................. 4-1 4.3 Explanations of Display Messages ..................................................... 4-1 4.4 How to Operate the Digital Keypad..................................................... 4-3 Chapter 5 Parameters ..................................................................................5-1 5.1 Summary of Parameter Settings......................................................... 5-2 5.2 Parameter Settings for Applications.................................................. 5-12 5.3 Description of Parameter Settings .................................................... 5-17 Chapter 6 Fault Code Information...............................................................6-1 6.1 Common Problems and Solutions ...................................................... 6-1 6.2 Reset .................................................................................................. 6-4 Chapter 7 Troubleshooting..........................................................................7-1 7.1 Over Current (OC) .............................................................................. 7-1 7.2 Ground Fault....................................................................................... 7-2 7.3 Over Voltage (OV) .............................................................................. 7-2 7.4 Low Voltage (Lv)................................................................................. 7-3 7.5 Over Heat (OH)................................................................................... 7-4 7.6 Overload ............................................................................................. 7-4 7.7 Keypad Display is Abnormal............................................................... 7-5 7.8 Phase Loss (PHL)............................................................................... 7-5 7.9 Motor cannot Run ............................................................................... 7-6 7.10 Motor Speed cannot be Changed..................................................... 7-7 7.11 Motor Stalls during Acceleration ....................................................... 7-8 7.12 The Motor does not Run as Expected .............................................. 7-8 7.13 Electromagnetic/Induction Noise ...................................................... 7-9 7.14 Environmental Condition................................................................... 7-9 7.15 Affecting Other Machines ............................................................... 7-10 Chapter 8 Maintenance and Inspections....................................................8-1 Appendix A Specifications ......................................................................... A-1 Appendix B Accessories ............................................................................B-1 B.1 All Brake Resistors & Brake Units Used in AC Motor Drives..............B-1 B.1.1 Dimensions and Weights for Brake resistors..............................B-2 B.2 EMI Filters ..........................................................................................B-3 B.2.1 Dimensions.................................................................................B-6 B.3 AC Reactor.......................................................................................B-10 B.3.1 AC Input Reactor Recommended Value...................................B-10 B.3.2 AC Output Reactor Recommended Value................................B-11 B.3.3 Applications for AC Reactor .....................................................B-11 B.4 DC Choke Recommended Values....................................................B-15 B.5 Zero Phase Reactor (RF220X00A) ..................................................B-16 B.6 Din Rail-DR01 ..................................................................................B-17 B.7 Remote Controller RC-01.................................................................B-18 B.8 Conduit Bracket (BK-S) ....................................................................B-19 B.9 Non-fuse Circuit Breaker Chart ........................................................B-20 Appendix C How to Select the Right AC Motor Drive............................... C-1 C.1 Capacity Formulas .............................................................................C-2 C.2 General Precautions ..........................................................................C-4 C.3 How to Choose a Suitable Motor........................................................C-5 Appendix D CE ............................................................................................D-1 Chapter 1 Introduction 1.1 Receiving and Inspection This VFD-S AC motor drive has gone through rigorous quality control tests at the factory before shipment. After receiving the AC motor drive, please check for the following: � Check to make sure that the package includes an AC motor drive, the User Manual/Quick Start and CD, dust covers and rubber bushings. � Inspect the unit to assure it was not damaged during shipment. � Make sure that the part number indicated on the nameplate corresponds with the part number of your order. 1.1.1 Nameplate Information Example for 1HP/0.75kW 3-phase 230V AC motor drive AC Drive Model MODEL : VFD007S23A Input Spec. INPUT : 3PH 200-240V 50/60Hz 5.1A Output Spec. OUTPUT : 3PH 0-240V 4.2A 1.6kVA 0.75kW/1HP Output Frequency Range Frequency Range : 1-400Hz Serial Number & Bar Code 007S23A0T7010001 DELTA ELECTRONICS INC. MADE IN XXXXX 1.1.2 Model Explanation VFD 007 S 23 A Version Type Input Voltage 11:Single phase 115V 21:Single phase 230V 23:Three phase 230V 43:Three phase 460V S Series Applicable motor capacity 002: 0.25HP(0.2kW) 004: 0.5HP(0.4kW) 007: 1 HP(0.7kW) 022: 3 HP(2.2kW) Series Name Revision August 2006, SE08, SW V2.61 1-1 Chapter 1 Introduction|VFD-S Series 1.1.3 Series Number Explanation 007S23A 0T 6 01 Production number Production week Production year 2006 Production factory (Taoyuan) 230V 3-phase 1HP(0.75kW) Model If the nameplate information does not correspond to your purchase order or if there are any problems, please contact your distributor. 1.1.4 Drive Frames Frame Power range Models VFD002S11A/11B/21A/21B/21E/23A, 0.25-2hp S1 VFD004S11A/11B/21A/21B/21E/23A/43A/43B/43E, (0.2-1.5kW) VFD007S21A/21B/21E/23A/43A/43B/43E, VFD015S23D 1-5hp VFD007S11A/11B, VFD015S21D/21E/21U/43D/43E/43U, S2 (0.75-3.7kW) VFD022S21D/21E/21U/23D/43D/43E/43U Please refer to Chapter 2.3 for exact dimensions. 1.2 Appearances VFD002S11A/11B/21A/21B/23A, Frame S1: VFD002S21E, VFD004S21E, VFD004S11A/11B/21A/21B/23A/43A/43B/43E, VFD007S21E, VFD015S23D, VFD007S21A/21B/23A/43A/43B/43E, Frame S2: VFD007S11A/11B, VFD015S21D/21E/21U/43D/43E/43U, VFD022S21D/21E/21U/23D/43D/43E/43U 1-2 Revision August 2006, SE08, SW V2.61 Chapter 1 Introduction|VFD-S Series 1.3 Installation Steps KNOB COVER CASE HEAT SINK SCREW DIVISION PLATE Installation Steps 1. Remove front cover screw and open. 2. Remove Division Plate. If using optional conduit bracket, please refer to next page. 3. Connect AC Input Power and motor leads. Never connect the AC drive output terminals U/T1, V/T2, W/T3 to main AC Input power. 4. Reinstall Division Plate. SCREW SCREW For Optional Conduit Bracket: Make sure to fasten both screws on conduit bracket as shown in the drawing for safety grounding purpose. Bring all the wires out through the conduit bracket. Screw Torque: 5 to 6 kgf-cm (4.3 to 5.2 in-lbf) CONDUIT BRACKET Revision August 2006, SE08, SW V2.61 1-3 Chapter 1 Introduction|VFD-S Series SCREW DIVISION PLATE Reinstall Division Plate. Screw Torque: 5 to 6 kgf-cm (4.3 to 5.2 in-lbf) CONDUIT BRACKET SCREW SCREW Install Conduit Bracket cover and tighten screws. 1.4 Storage The AC motor drive should be kept in the shipping carton or crate before installation. In order to retain the warranty coverage, the AC motor drive should be stored properly when it is not to be used for an extended period of time. Storage conditions are: Store in a clean and dry location free from direct sunlight or corrosive fumes. ° ° Store within an ambient temperature range of -20 C to +60 C. Store within a relative humidity range of 0% to 90% and non-condensing environment. Store within an air pressure range of 86kPa to 106kPa. CAUTION! 1. DO NOT store in an area with rapid changes in temperature. It may cause condensation and frost. 2. DO NOT place on the ground directly. It should be stored properly. Moreover, if the surrounding environment is humid, you should put exsiccator in the package. 1-4 Revision August 2006, SE08, SW V2.61 Chapter 1 Introduction|VFD-S Series 3. If the AC motor drive is stored for more than 3 months, the temperature should not be higher than 30 °C. Storage longer than one year is not recommended, it could result in the degradation of the electrolytic capacitors. 4. When the AC motor drive is not used for a long time after installation on building sites or places with humidity and dust, it’s best to move the AC motor drive to an environment as stated above. Revision August 2006, SE08, SW V2.61 1-5 Chapter 1 Introduction|VFD-S Series This page intentionally left blank. 1-6 Revision August 2006, SE08, SW V2.61 Chapter 2 Installation and Wiring 2.1 Ambient Conditions Install the AC motor drive in an environment with the following conditions: Operation Air Temperature: -10 ~ +50°C (14 ~ 122°F) -10 ~ +40°C (14 ~ 104°F) for side-by-side mounting Relative Humidity: <90%, no condensation allowed Atmosphere pressure: 86 ~ 106 kPa Installation Site Altitude: <1000m 2 Vibration: <20Hz: 9.80 m/s (1G) max 2 20 ~ 50Hz: 5.88 m/s (0.6G) max Storage Temperature: -20°C ~ +60°C (-4°F ~ 140°F) Transportation Relative Humidity: <90%, no condensation allowed Atmosphere pressure: 86 ~ 106 kPa 2 Vibration: <20Hz: 9.80 m/s (1G) max 2 20 ~ 50Hz: 5.88 m/s (0.6G) max Pollution Degree 2: good for a factory type environment. CAUTION! 1. Operating, storing or transporting the AC motor drive outside these conditions may cause damage to the AC motor drive. 2. Failure to observe these precautions may void the warranty! 2.2 Installation 1. Mount the AC motor drive vertically on a flat vertical surface by using bolts or screws. Other directions are not allowed. 2. The AC motor drive will generate heat during operation. Allow sufficient space around the unit for heat dissipation. 3. The heat sink temperature may rise to 90°C when running. The material on which the AC motor drive is mounted must be noncombustible and be able to withstand this high temperature. 4. When the AC motor drive is installed in a confined space (e.g. cabinet), the surrounding temperature must be within 10 ~ 40°C with good ventilation. DO NOT install the AC motor drive in a space with bad ventilation. Revision August 2006, SE08, SW V2.61 2-1 50mm (2inch) 50mm (2inch) Chapter 2 Installation and Wiring|VFD-S Series 5. When installing multiple AC motor drives in the same cabinet, they should be adjacent in a row with enough space. When installing one AC motor drive below another one, use a metal separation barrier between the AC motor drives to prevent mutual heating. Refer to figure below for details. 6. Prevent fiber particles, scraps of paper, saw dust, metal particles, etc. from adhering to the heatsink. Mounting Clearances 150mm (6inch) Air Flow 150mm (6inch) 2-2 Revision August 2006, SE08, SW V2.61 Chapter 2 Installation and Wiring|VFD-S Series 2.3 Dimensions (Dimensions are in millimeter and [inch]) Frame S1: VFD002S11A, VFD002S21A, VFD002S23A 85.0 [3.35] 5.8 [0.23] 88.0 [3.47] 13.0 [0.51] 74.0 [2.92] 5.0 [0.20] 5.0 [0.20] Revision August 2006, SE08, SW V2.61 2-3 132.2 [5.21] 148.0 [5.83] 3.0 [0.12] 11.1 [0.44] 8.1 [0.32] Chapter 2 Installation and Wiring|VFD-S Series Frame S1: VFD002S11B, VFD002S21B 85 .0 [3 .3 5] 5.8 [0.23 ] 88 .0 [3 .4 7] 74 .0 [2 .9 2] 13 .0 [0 .5 1] 73 .0 [2 .8 8] 67 .8 [2 .6 7] 13 .0 [0 .5 1] 5.0 [0. 20 ] 5. 0 [0.20 ] 2-4 Revision August 2006, SE08, SW V2.61 13 2.2 [5.21] 5.83] 1 6.0 [ 0.63] 14 8.0 [ 3.0 [0.12] 1 1.1 [ 0.44] [0.32] 8.1 Chapter 2 Installation and Wiring|VFD-S Series Frame S1: VFD004S11A, VFD004S21A, VFD004S23A 85 .0 [3 .3 5] 5.8 [0.23 ] 10 2.0 [4.02] 74 .0 [2 .9 2] 2.8 [0.11 ] 5.0 [0.20 ] 5.0 [0.20 ] Revision August 2006, SE08, SW V2.61 2-5 1 32.2 [5.21] 1 48.0 [5.83] 3.0 [ 0.12] 11.1 [0.44] 8.1 [0.32] Chapter 2 Installation and Wiring|VFD-S Series Frame S1: VFD004S11B, VFD004S21B 85 .0 [3 .3 5] 5. 8 [0. 23 ] 10 2. 0 [ 4. 02] 7 74 4 ..0 0 [2 [2 .9 .9 2 2]] 2. 8 [0.11 ] 73 .0 [2 .8 8] 67 .8 [2 .6 7] 27 .0 [1 .0 6] 5. 0 [0. 20 ] 5.0 [0.20 ] 2-6 Revision August 2006, SE08, SW V2.61 1 32.2 [5.21] 16.0 [0.63] 1 48.0 [5.83] 3.0 [0.12] 11.1 [0.44] 8.1 [ 0.32] Chapter 2 Installation and Wiring|VFD-S Series Frame S1: VFD007S21A, VFD007S23A 85 .0 [3 .3 5] 5. 8 [0.23 ] 12 4.0 [4. 89] 74 .0 [2 .9 2] 2. 8 [0.11 ] 5.0 [0. 20 ] 5.0 [0. 20 ] Revision August 2006, SE08, SW V2.61 2-7 13 2.2 [ 5.21] 14 8.0 [ 5.83] 0 [0 .12] 3. 1 1.1 [ 0.44] 8.1 [ 0.32] Chapter 2 Installation and Wiring|VFD-S Series Frame S1: VFD007S21B 85 .0 [3 .3 5] 5.8 [0. 23 ] 12 4.0 [ 4.89] 7 74 4 .0 .0 [2 [2 .9 .9 2 2]] 2.8 [0. 11 ] 67 .8 [2 .6 7] 50 .0 [1 .9 7] 73 .0 [2 .8 8] 5.0 [0.20 ] 5.0 [0. 20 ] 2-8 Revision August 2006, SE08, SW V2.61 1 32.2 [5.21] 16.0 [0.63] 148.0 [5.83] 3. 0 [0.12] 11 .1 [0.44] 8.1 [0.32] Chapter 2 Installation and Wiring|VFD-S Series Frame S1: VFD004S43A, VFD004S43E, VFD007S43A, VFD007S43E 85 .0 [3 .3 5] 5. 8 [0. 23 ] 12 6. 0 [ 4. 96] 74 .0 [2 .9 2] 3.0 [0.12 ] 5. 0 [0. 20 ] 5. 0 [0. 20 ] Revision August 2006, SE08, SW V2.61 2-9 13 2.2 [ 5.21] 14 8.0 [ 5.83] 3.0 [0 .12] 1 1.1 [ 0.44] 8.1 [0.32] Chapter 2 Installation and Wiring|VFD-S Series Frame S1: VFD004S43B, VFD007S43B 85 .0 [3 .3 5] 5.8 [0. 23 ] 12 6.0 [4.96] 74 .0 [2 .9 2] 3. 0 [0.12 ] 73 .0 [2 .8 8] 67 .8 [2 .6 7] 51 .0 [2 .0 1] 5. 0 [0.20 ] 5.0 [0.20 ] 2-10 Revision August 2006, SE08, SW V2.61 1 32.2 [5.21] 16.0 [0.63] 148.0 [5.83] 3. 0 [0.12] 11 .1 [0 .44] 8.1 [0 .32] Chapter 2 Installation and Wiring|VFD-S Series Frame S1: VFD002S21E, VFD004S21E, VFD007S21E, VFD015S23D 85 .0 [3 .3 5] 5. 8 [ 0. 23 ] 12 7.0 [5.00] 74 .0 [2 .9 2] 8. 5 [ 0. 33 ] 5.0 [0.20 ] Revision August 2006, SE08, SW V2.61 2-11 13 3.7 [ 5.27] 14 8.0 [ 5.83] 8.3 [ 0.33] Chapter 2 Installation and Wiring|VFD-S Series Frame S2: VFD007S11A 10 0.0 [3. 94] 86 .5 [3 .4 1] 5. 4 [0.21 ] 12 9.0 [5. 08] 5. 5 [0. 22 ] 5. 5 [0.22 ] 2-12 Revision August 2006, SE08, SW V2.61 1 73.0 [6.81] 1 86.0 [7.33] 1 .0 [0 .04] 9 .5 [0 .38] 6.5 [ 0.26] Chapter 2 Installation and Wiring|VFD-S Series Frame S2: VFD007S11B 10 0.0 [3.94] 86 .5 [3 .4 1] 5.4 [0.21 ] 12 9.0 [5.08] 73 .0 [2 .8 8] 67 .8 [2 .6 7] 53 .5 [2 .11] 5.5 [0. 22 ] 5. 5 [0. 22 ] Revision August 2006, SE08, SW V2.61 2-13 173 .0 [6.82] 16 .0 [0 .63] 18 6.0 [7.33] 1.0 [0 .04] 9.5 [0 .38] 6.5 [0.26] Chapter 2 Installation and Wiring|VFD-S Series Frame S2: VFD015S21D, VFD015S21E, VFD015S43D, VFD015S43E, VFD022S21D, VFD022S21E, VFD022S23D, VFD022S43D, VFD022S43E 10 0.0 [3.94] 5.4 [0.21 ] 12 9.3 [5.09] 86 .5 [3 .4 1] 8.5 [0.33 ] 5. 5 [0.22 ] 5.5 [0.22 ] 2-14 Revision August 2006, SE08, SW V2.61 17 3.0 [ 6.82] 18 6.0 [ 7.33] 1.0 [0.04] 9 .5 [0 .37] ] 6.5 [0.26 Chapter 2 Installation and Wiring|VFD-S Series Frame S2: VFD015S21U, VFD015S43U, VFD022S21U, VFD022S43U 5.4 [0.21] 129.3 [5.09] 100.0 [3.94] 86.5 [3.41] 8.5 [0.33] 67.8 [2.67] 53.9 [2.12] 73.0 [2.88] 5.5 [0.22] 5.5 [0.22] Revision August 2006, SE08, SW V2.61 2-15 173.0 [6.82] 16.0 [0.63] 186.0 [7.33] 1.0 [0.04] 9.5 [0.37] 6.5 [0.26] Chapter 2 Installation and Wiring|VFD-S Series 2.4 Wiring After removing the front cover, check if the power and control terminals are clear of debris. Be sure to observe the following precautions when wiring. General Wiring Information � Applicable Codes All VFD-S series are Underwriters Laboratories, Inc. (UL) and Canadian Underwriters Laboratories (cUL) listed, and therefore comply with the requirements of the National Electrical Code (NEC) and the Canadian Electrical Code (CEC). Installation intended to meet the UL and cUL requirements must follow the instructions provided in “Wiring Notes” as a minimum standard. Follow all local codes that exceed UL and cUL requirements. Refer to the technical data label affixed to the AC motor drive and the motor nameplate for electrical data. The "Line Fuse Specification" in Appendix B, lists the recommended fuse part number for each S-Series part number. These fuses (or equivalent) must be used on all installations where compliance with U.L. standards is a required. 2-16 Revision August 2006, SE08, SW V2.61 Chapter 2 Installation and Wiring|VFD-S Series 2.4.1 Basic Wiring � Make sure that power is only applied to the R/L1, S/L2, T/L3 terminals. Failure to comply may result in damage to the equipment. The voltage and current should lie within the range as indicated on the nameplate. � Check the following items after completing the wiring: 1. Are all connections correct? 2. No loose wires? 3. No short-circuits between terminals or to ground? A charge may still remain in the DC bus capacitors with hazardous voltages even if the power has been turned off. To prevent personal injury, please ensure that the power is turned off and wait ten minutes for the capacitors to discharge to safe voltage levels before opening the AC motor drive. DANGER! 1. All the units must be grounded directly to a common ground terminal to prevent electric shock, fire and interference. 2. Only qualified personnel familiar with AC motor drives are allowed to perform installation, wiring and commissioning. 3. Make sure that the power is off before doing any wiring to prevent electric shocks. Basic Wiring Diagrams Users must connect wires according to the circuit diagrams on the following pages. Do not plug a modem or telephone line to the RS-485 communication port or permanent damage may result. Terminals 1 & 2 are the power supply for the optional copy keypad only and should not be used for RS-485 communication. Revision August 2006, SE08, SW V2.61 2-17 Chapter 2 Installation and Wiring|VFD-S Series For VFDXXXSXXA/B/D/U Main Circuit Power E NFB R/L1 R/L1 S/L2 S/L2 T/L3 T/L3 17V SA Recommended Circuit RB Grounding resistance when power supply MC less than 100 is turned OFF by a RC ON OFF fault output MC 17V 4.7k 17V 4.7k 17V 4.7k 17V 4.7k 17V 4.7k 17V 4.7k 47K 2-18 Revision August 2006, SE08, SW V2.61 Chapter 2 Installation and Wiring|VFD-S Series For VFDXXXSXXE NPN (sink mode) Braking resistor (optional) Jumper select 80ΩΩ 120W, 200 120W 400Ω 120W Main Circuit Power B2 +1 AC Motor +2/B1 E U/T1 NFB R/L1 IM R/L1 V/T2 S/L2 S/L2 +17V 3~ W/T3 T/L3 T/L3 Grounding resistance SA CPU E less than 100Ω Recommended Circuit RB when power supply MC Potentiometer(1KΩ) is turned OFF by a RC 2.4Ω 47ΩAFM ON OFF fault output MC Analog output + Factory default 47KΩ DC 0~10V 17V - 11V Forward/Stop M0 Factory default: indicate Reverse/Stop GND M1 output frequency Reset M2 NPN RA Multi-function indication Multi-step 1 PNP output contacts below M3 RB 120VAC/24VDC 5A Multi-step 2 J2 M4 RC Multi-step 3 Factory default: M5 indicates malfunction Comm. signal (sink) GND Mo1 Multi-function Photocoupler E output below 48VDC 50mA +10V 10mA Analog voltage 3 Factory default: Indicates 01 ~0VDC (MAX) 1 2 during operation 2 MCM Potentiometer Pot. 3K~Ω 5K AVI RJ-11 3 RJ-11 communication port with Analog current 1 47KΩ 250Ω RS-485 serial interface 1:17V GND 61 ← 2:GND Factory default: output freq. (Pot.) 3:SG- determined by the Potentiometer 4:SG+ on the control panel. Main circuit (power) terminals Control circuit terminals Shielded leads NOTE: Do not plug in a Modem or telephone line to the RS-485 communication port, permanent damage may result. Terminal 1 & 2 are the power sources for the optional copy keypad and should not be used while using RS-485 communication. * If it is single phase model, please select any of the two input power terminals in main circuit power. Revision August 2006, SE08, SW V2.61 2-19 Chapter 2 Installation and Wiring|VFD-S Series For VFDXXXSXXE PNP (source mode) Braking resistor (optional) Jumper select 80ΩΩ 120W, 200 120W 400Ω 120W Main Circuit Power +1 +2/B1 B2 E NFB AC Motor R/L1 R/L1 U/T1 S/L2 S/L2 IM V/T2 T/L3 T/L3 +17V 3~ SA W/T3 Recommended Circuit Grounding resistance RB when power supply MC CPU E less than 100Ω RC is turned OFF by a ON OFF fault output MC 2.4Ω Potentiometer(1KΩ) AFM 47Ω Common signal (source) Analog output + 47KΩ DC 0~10V 17V 20mA - 11V Forward/Stop M0 Factory default: indicate Reverse/Stop GND M1 output frequency Reset M2 NPN RA Multi-function indication Multi-step 1 PNP output contacts below M3 RB 120VAC/24VDC 5A Multi-step 2 J2 M4 RC Multi-step 3 Factory default: M5 indicates malfunction GND Mo1 Multi-function Photocoupler E output below 48VDC 50mA +10V 10mA Analog voltage 3 Factory default: Indicates 01 ~0VDC (MAX) 1 2 MCM during operation Potentiometer 2 Pot. 3K~Ω 5K AVI RJ-11 3 RJ-11 communication port with 1 47KΩ Analog current 250Ω RS-485 serial interface 1:17V GND 61 ← 2:GND Factory default: output freq. (Pot.) 3:SG- determined by the Potentiometer 4:SG+ on the control panel. Main circuit (power) terminals Control circuit terminals Shielded leads NOTE: Do not plug in a Modem or telephone line to the RS-485 communication port, permanent damage may result. Terminal 1 & 2 are the power sources for the optional copy keypad and should not be used while using RS-485 communication. * If it is single phase model, please select any of the two input power terminals in main circuit power. 2-20 Revision August 2006, SE08, SW V2.61 Chapter 2 Installation and Wiring|VFD-S Series 2.4.2 External Wiring Power Supply Items Explanations Please follow the specific power Power supply requirements shown in supply FUSE/NFB Appendix A. There may be an inrush current during power up. Please check the Fuse/NFB Magnetic chart of Appendix B and select the (Optional) contactor correct fuse with rated current. Use of an NFB is optional. Please do not use a Magnetic Magnetic Input AC contactor as the I/O switch of the AC Line Reactor contactor motor drive, as it will reduce the (Optional) operating life cycle of the AC drive. Zero-phase Reactor Used to improve the input power factor, to reduce harmonics and provide protection from AC line EMI Filter disturbances. (surges, switching Input AC spikes, short interruptions, etc.). AC Line Reactor line reactor should be installed when (Optional) R/L1 S/L2 T/L3 the power supply capacity is 500kVA DC +1 Choke or more and exceeds 6 times the +2/B1 inverter capacity, or the mains wiring Braking Resistor distance ≤ 10m. B2 Zero phase reactors are used to U/T1 V/T2 W/T3 reduce radio noise especially when Zero-phase audio equipment is installed near the Reactor inverter. Effective for noise reduction Zero-phase (Ferrite Core Reactor on both the input and output sides. Common Attenuation quality is good for a wide Output AC Choke) range from AM band to 10MHz. Line Reactor (Optional) Appendix B specifies the zero phase reactor. (RF220X00A) To reduce electromagnetic EMI filter Motor interference, please refer to Appendix (Optional) B for more details. Used to reduce the deceleration time Brake of the motor. Please refer to the chart resistor in Appendix B for specific brake (Optional) resistors. Motor surge voltage amplitude Output AC depends on motor cable length. For Line Reactor applications with long motor cable (Optional) (>20m), it is necessary to install a reactor at the inverter output side. Revision August 2006, SE08, SW V2.61 2-21 Chapter 2 Installation and Wiring|VFD-S Series 2.4.3 Main Terminals Connections Terminal Symbol Explanation of Terminal Function R/L1, S/L2, T/L3 AC line input terminals (3-phase) L/L1, N/L2 AC line input terminals (1-phase) AC drive output terminals for connecting 3-phase U/T1, V/T2, W/T3 induction motor +2/B1, B2 Connections for Brake resistor (optional) +2/B1, +1 Connections for DC Link Reactor (optional) Earth connection, please comply with local regulations. Mains power terminals (R/L1, S/L2, T/L3 and L/L1, N/L2) � Connect these terminals via a non-fuse breaker or earth leakage breaker to 3-phase AC power (some models to 1-phase AC power) for circuit protection. It is unnecessary to consider phase-sequence. � It is recommended to add a magnetic contactor (MC) in the power input wiring to cut off power quickly and reduce malfunction when activating the protection function of AC motor drives. Both ends of the MC should have an R-C surge absorber. � Do NOT run/stop AC motor drives by turning the power ON/OFF. Run/stop AC motor drives by RUN/STOP command via control terminals or keypad. If you still need to run/stop AC drives by turning power ON/OFF, it is recommended to do so only ONCE per hour. � Do NOT connect 3-phase models to a 1-phase power source. Control circuit terminals (U/T1, V/T2, W/T3) � When the AC drive output terminals U/T1, V/T2, and W/T3 are connected to the motor terminals U/T1, V/T2, and W/T3, respectively, the motor will rotate counterclockwise (as viewed on the shaft end of the motor) when a forward operation command is received. To permanently reverse the direction of motor rotation, switch over any of the two motor leads. Forward running 2-22 Revision August 2006, SE08, SW V2.61 Chapter 2 Installation and Wiring|VFD-S Series � DO NOT connect phase-compensation capacitors or surge absorbers at the output terminals of AC motor drives. � With long motor cables, high capacitive switching current peaks can cause over-current, high leakage current or lower current readout accuracy. To prevent this, the motor cable should be less than 20m for 3.7kW models and below. And the cable should be less than 50m for 5.5kW models and above. For longer motor cables use an AC output reactor. � Use a well-insulated motor, suitable for inverter operation. Terminals [+2/B1, +1] for connecting DC reactor � This is the connector for the DC reactor to improve the power factor. Please remove the short jumper when connecting DC reactor. Terminals [+2/B1, B2] for connecting brake resistor BR +2/B1 B2 Connect a brake resistor in applications with frequent deceleration ramps, short � deceleration time, too low braking torque or requiring increased braking torque. When not used, please leave the terminals [+2/B1, B2] open. � WARNING! Short-circuiting [+2/B1, B2] can damage the AC motor drive. Grounding terminals ( ) � Make sure that the leads are connected correctly and the AC drive is properly grounded. Ω (Ground resistance should not exceed 0.1 .) � Use ground leads that comply with local regulations and keep them as short as possible. � Multiple VFD-S units can be installed in one location. All the units should be grounded directly to a common ground terminal, as shown in the figure below. Ensure there are no ground loops. excellent good not allowed Revision August 2006, SE08, SW V2.61 2-23 Chapter 2 Installation and Wiring|VFD-S Series 2.4.4 Control Terminals Control Terminal Wiring (Factory Setting) A. XXXSXXA/B/D/U +10V AVIAFM M0 M1 M2 M3 M4 M5GND RA Relay contactor output RB Factory setting : Fault indication RC MO1 Photo coupler output Operation freq. setting MCM Factory setting : in work potentiometer VR : 3K~5K Corrector RJ11 RS485 Communication port potentiometer Multi-step speed 3 VR : 1K~5K Multi-step speed 2 6 ~ 1 Multi-step speed 1 Reset Freq. meter Wire Gauge: 24-12 AWG Reverse/Stop 0~10 VDC Full scale voltmeter Forward/Stop Wire Type: Copper Only Torque: 4 kgf-cm (3.5 in-lbf) B. XXXSXXE * * Multi-step speed 3 Wire Gauge: 24-16 AWG Wire Type: Copper Only Torque: 2 kgf-cm (1.7 in-lbf) Terminal symbols and functions Terminal Factory Settings (NPN mode) Terminal Function Symbol ON: Connect to GND Refer to Pr.4-04 to Pr.4-08 for programming the M0 Multi-function auxiliary input Multi-function Inputs. ON: the activation current is 16mA. M1 Multi-function input 1 OFF: leakage current tolerance is 10μA. M2 Multi-function input 2 M3 Multi-function input 3 2-24 Revision August 2006, SE08, SW V2.61 Chapter 2 Installation and Wiring|VFD-S Series Terminal Factory Settings (NPN mode) Terminal Function Symbol ON: Connect to GND M4 Multi-function input 4 M5 Multi-function Input 5 +17V DC Voltage Source +17VDC, 20mA used for PNP mode. Common for digital inputs and used for NPN GND Digital Signal Common mode. AFM circuit AFM 0~10V AFM Analog output meter ondometer Max. 2mA GND Internal Circuit Multi-function Relay output RA Resistive Load: (N.O.) a 5A(N.O.)/3A(N.C.) 240VAC 5A(N.O.)/3A(N.C.) 24VDC Multi-function Relay output Inductive Load: RB (N.C.) b 1.5A(N.O.)/0.5A(N.C.) 240VAC 1.5A(N.O.)/0.5A(N.C.) 24VDC Refer to Pr.3-06 for programming RC Multi-function Relay common Maximum 48VDC, 50mA Refer to Pr.3-01 for programming Max: 48Vdc MO1-DCM 50mA Mo1 Multi-function Output 1 MO1 (Photocoupler) MCM internal circuit MCM Multi-function output common Max. 48Vdc 50mA +10V Potentiometer power supply +10VDC 10mA (variable resistor: 3~5kohm) Revision August 2006, SE08, SW V2.61 2-25 Chapter 2 Installation and Wiring|VFD-S Series Terminal Factory Settings (NPN mode) Terminal Function Symbol ON: Connect to GND 0~+10V/4-20mA corresponds to 0-max. operation frequency (Pr.01-00) PID feedback signal AVI input impedance: 100kohm ACI input impedance: 250kohm AVI AVI circuit +10V ACI J1 Analog voltage Input AVI (AVI/ACI) AVI GND Internal Circuit AVI ACI circuit ACI ACI J1 GND Internal Circuit 2 Control signal wiring size: 18 AWG (0.75 mm ) with shielded wire. Analog input terminals (AVI, GND) � Analog input signals are easily affected by external noise. Use shielded wiring and keep it as short as possible (<20m) with proper grounding. If the noise is inductive, connecting the shield to terminal GND can bring improvement. � If the analog input signals are affected by noise from the AC motor drive, please connect μ a capacitor (0.1 F and above) and ferrite core as indicated in the following diagrams: AVI C GND ferrite core wind each wires 3 times or more around the core Digital inputs (M0~M5, GND) � When using contacts or switches to control the digital inputs, please use high quality components to avoid contact bounce. 2-26 Revision August 2006, SE08, SW V2.61 Chapter 2 Installation and Wiring|VFD-S Series Digital outputs (MO1, MCM) � Make sure to connect the digital outputs to the right polarity, see wiring diagrams. � When connecting a relay to the digital outputs, connect a surge absorber or fly-back diode across the coil and check the polarity. General � Keep control wiring as far as possible from the power wiring and in separate conduits to avoid interference. If necessary let them cross only at 90º angle. � The AC motor drive control wiring should be properly installed and not touch any live power wiring or terminals. NOTE � If a filter is required for reducing EMI (Electro Magnetic Interference), install it as close as possible to AC drive. EMI can also be reduced by lowering the Carrier Frequency. � When using a GFCI (Ground Fault Circuit Interrupter), select a current sensor with sensitivity of 200mA, and not less than 0.1-second detection time to avoid nuisance tripping. DANGER! Damaged insulation of wiring may cause personal injury or damage to circuits/equipment if it comes in contact with high voltage. Revision August 2006, SE08, SW V2.61 2-27 Chapter 2 Installation and Wiring|VFD-S Series 2.4.5 Main Circuit Terminals VFD002S11A/11B, VFD004S11A/11B Power terminal AC Input Line Motor Terminal Connection Ground Braking Resistor Power Terminal: Torque: 12 kgf-cm (10 lbf-in) 2 Wire Gauge: 14-20 AWG (2.1-0.5mm ) o Wire Type: Copper only, 75 C 2-28 Revision August 2006, SE08, SW V2.61 Chapter 2 Installation and Wiring|VFD-S Series VFD002S21B/23A, VFD004S21B/23A/43A/43B/43E, VFD007S21B/23A/43A/43B/43E, VFD015S23D Power terminal AC Input Line Motor Terminal Connection Ground Braking DC Reactor Resistor Power Terminal: Torque: 12 kgf-cm (10 lbf-in) 2 Wire Gauge: 14-20 AWG (2.1-0.5mm ) o Wire Type: Copper only, 75 C Revision August 2006, SE08, SW V2.61 2-29 Chapter 2 Installation and Wiring|VFD-S Series VFD002S21A/E, VFD004S21A/E, VFD007S21A/E Power terminal AC Input Line Motor Terminal Connection Braking Ground DC Reactor Resistor Power Terminal: Torque: 12 kgf-cm (10 lbf-in) 2 Wire Gauge: 14-20 AWG (2.1-0.5mm ) o Wire Type: Copper only, 75 C 2-30 Revision August 2006, SE08, SW V2.61 Chapter 2 Installation and Wiring|VFD-S Series VFD007S11A/B Power terminal AC Input Line Motor Terminal Connection Ground Braking Resistor Power Terminal: Torque: 20 kgf-cm (17.4 lbf-in) 2 Wire Gauge: 10-18 AWG (5.3-0.8mm ) o Wire Type: stranded copper only, 75 C Revision August 2006, SE08, SW V2.61 2-31 Chapter 2 Installation and Wiring|VFD-S Series VFD015S21U/43D/43E/43U, VFD022S21U/23D/43D/43E/43U Power terminal AC Input Line Motor Terminal Connection Braking Ground DC Reactor Resistor Power Terminal: Torque: 20 kgf-cm (17.4 lbf-in) 2 Wire Gauge: 10-18 AWG (5.3-0.8mm ) o Wire Type: stranded copper only, 75 C 2-32 Revision August 2006, SE08, SW V2.61 Chapter 2 Installation and Wiring|VFD-S Series VFD015S21D/E, VFD022S21D/E Power terminal AC Input Line Motor Terminal Connection Ground Braking DC Reactor Resistor Power Terminal: Torque: 20 kgf-cm (17.4 lbf-in) 2 Wire Gauge: 10-18 AWG (5.3-0.8mm ) o Wire Type: stranded copper only, 75 C Revision August 2006, SE08, SW V2.61 2-33 Chapter 2 Installation and Wiring|VFD-S Series This page intentionally left blank 2-34 Revision August 2006, SE08, SW V2.61 Chapter 3 Start Up 3.1 Preparations before Start-up Carefully check the following items before proceeding. � Make sure that the wiring is correct. In particular, check that the output terminals U/T1, V/T2, W/T3 are NOT connected to power and that the drive is well grounded. � Verify that there are no short-circuits between terminals and from terminals to ground or mains power. � Check for loose terminals, connectors or screws. � Verify that no other equipment is connected to the AC motor. � Make sure that all switches are OFF before applying power to ensure that the AC motor drive doesn’t start running and there is no abnormal operation after applying power. � Make sure that the front cover is correctly installed before applying power. � Do NOT operate the AC motor drive with humid hands. � Check the following items after applying power: The display without digital keypad should be as following. -The keypad should light up as follows (normal status with no error) RUN STOP FWD REV When power is ON, LEDs “STOP” and “FWD” should light up. The STOP/RESET RUN MIN. MAX. display will show “F60.0”. PROG MODE DATA - If the drive has built-in fan, it should run. Revision August 2006, SE08, SW V2.61 3-1 Chapter 3 Start Up| VFD-S Series 3.2 Operation Method Refer to 4.2 How to operate the digital keypad and chapter 5 parameters for setting. Please choose a suitable method depending on application and operation rule. The operation is usually done as shown in the following table. Operation Command Operation Method Frequency Source Source Keypad RUN STOP/RESET MI2 Parameter setting: External terminals MI3 4-05=10 Operate from input: 4-06=11 external signal M0-GND GND M1-GND AVI, ACI 3.3 Trial Run After finishing checking the items in “3.1 preparation before start-up”, you can perform a trial run. 1. After applying power, verify that the display shows “F60.0”. 2. Setting frequency to about 5Hz by using key. RUN 3. Pressing key for forward running. And if you want to change to reverse running, you should press key in page. And if you want to decelerate to stop, please STOP/RESET press key. 4. Check following items: � Check if the motor direction of rotation is correct. � Check if the motor runs steadily without abnormal noise and vibration. � Check if acceleration and deceleration are smooth. If the results of trial run are normal, please start the formal run. 3-2 Revision August 2006, SE08, SW V2.61 Chapter 3 Start Up| VFD-S Series NOTE 1. Stop running immediately if any fault occurs and refer to the troubleshooting guide for solving the problem. 2. Do NOT touch output terminals U/T1, V/T2, W/T3 when power is still applied to R/L1, S/L2, T/L3 even when the AC motor drive has stopped. The DC-link capacitors may still be charged to hazardous voltage levels, even if the power has been turned off. 3. To avoid damage to components, do not touch them or the circuit boards with metal objects or your bare hands. Revision August 2006, SE08, SW V2.61 3-3 Chapter 3 Start Up| VFD-S Series This page intentionally left blank 3-4 Revision August 2006, SE08, SW V2.61 Chapter 4 Digital Keypad Operation 4.1 Description of the Digital Keypad LED Display LED indication Indicate frequency, motor Light during RUN, parameter setting value STOP, FWD and and alarm contents. REV operation. RUN STOP RUN Key FWD Start inverter drive operation. REV STOP/RESET Key Potentiometer for Stop inverter drive operation frequency setting. and reset the inverter after Could be the Master faults occurred. Frequency input STOP/RESET RUN by setting Pr.2-00. PROG/DATA Key MIN. MAX. Set the different parameters and enter information. Mode Key PROG Change between MODE UP and DOWN Key DATA Sets the parameter number different display modes. or changes the numerical data such as the freq. reference. 4.2 Explanation of LED Indicators Stop AC drive when STOP button has been pressed. RUN STOP FWD REV REV LED lights during reverse operation. FWD LED lights during forward operation. RUN LED lights during RUN operation. 4.3 Explanations of Display Messages Display Message Descriptions Displays the AC drive Master Frequency. Displays the actual output frequency at terminals U/T1, V/T2, and W/T3. User defined unit (where U = F x Pr.00.05) Displays the output current at terminals U/T1, V/T2, and W/T3. Revision August 2006, SE08, SW V2.61 4-1 Chapter 4 Digital Keypad Operation|VFD-S Series Display Message Descriptions The internal PLC process step currently being performed. Displays the DC-BUS voltage Displays the output voltage Displays the AC motor drive forward run status. Displays the AC motor drive reverse run status. The counter value (C). Displays the selected group. Displays the selected parameter. Displays the actual stored value of the selected parameter. Display “End” for approximately 0.5 second if input has been. After a parameter value has been set, the new value is automatically stored in memory. To modify an entry, use the keys. Display “Err”, if the input is invalid. 4-2 Revision August 2006, SE08, SW V2.61 Chapter 4 Digital Keypad Operation|VFD-S Series 4.4 How to Operate the Digital Keypad Setting Mode START GO START Note: In the selection mode, press to set the parameters. Setting parameters move down to the previous display or Success to Input data error set parameter. move up to the previous display NOTE: In the parameter setting mode, you can press to return the selecting mode. To shift data START Setting direction (When operation source is digital keypad) or or Revision August 2006, SE08, SW V2.61 4-3 Chapter 4 Digital Keypad Operation|VFD-S Series This page intentionally left blank 4-4 Revision August 2006, SE08, SW V2.61 Chapter 5 Parameters The VFD-S parameters are divided into 11 groups by property for easy setting. In most applications, the user can finish all parameter settings before start-up without the need for re-adjustment during operation. The 11 groups are as follows: Group 0: User Parameters Group 1: Basic Parameters Group 2: Operation Method Parameters Group 3: Output Function Parameters Group 4: Input Function Parameters Group 5: Multi-Step Speed and PLC Parameters Group 6: Protection Parameters Group 7: Motor Parameters Group 8: Special Parameters Group 9: Communication Parameters Group A: PID Parameters Revision August 2006, SE08, SW V2.61 5-1 Chapter 5 Parameters|VFD-S Series 5.1 Summary of Parameter Settings �: The parameter can be set during operation. Group 0 User Parameters Factory Pr. Explanation Settings NOTE Setting 0-00 Identity Code of the AC Motor Drive Read-only d # 0-01 Rated Current Display of the AC Read-only d##.# Motor Drive 0-02 Parameter Reset d09: All parameters are reset to d0 factory settings (50Hz, 220V/380V) d10: All parameters are reset to factory settings (60Hz, 220V/440V) d0: Display the frequency command value (LED F) d1: Display the actual output frequency (LED H) �0-03 Start-up Display Selection d2: Multifunction display, see Pr.00- d0 04 d3: Display output current (LED A) d4: Display forward/reverse command (Frd/rEv) d0: Display User-Defined Unit (u) d1: Display Counter Value (C) d2: Display Process Operation (1.tt) u d3: Display DC-BUS Voltage ( ) �0-04 Content of Multi-Function Display d4: Display output voltage (E) d0 d5: Display frequency commands of PID (P) d6: Display analog feedback signal value (b) (%) �0-05 User-Defined Coefficient K d0.1 to d160 d1.0 0-06 Software Version Read-only d#.# 0-07 Password Input d0 to d999 d0 0-08 Password Set d0 to d999 d0 �0-09 Memory Mode Selections d0 to d63 d8 Group 1 Basic Parameters Factory Pr. Explanation Settings NOTE Setting 1-00 Maximum Output Frequency (Fmax) d50.0 to d400 Hz d60.0 1-01 Maximum Voltage Frequency (Fbase) d10.0 to d400 Hz d60.0 230V series: d2.0V to d255V d220 1-02 Maximum Output Voltage (Vmax) 460V series: d4.0V to d510V d440 1-03 Mid-Point Frequency (Fmid) d1.0 to d400 Hz d1.0 1-04 Mid-Point Voltage (Vmid) 230V series: d2.0V to d255V d12 5-2 Revision August 2006, SE08, SW V2.61 Chapter 5 Parameters|VFD-S Series Factory Pr. Explanation Settings NOTE Setting 460V series: d4.0V to d510V d24 1-05 Minimum Output Frequency (Fmin) d1.0 to d60.0 Hz d1.0 Minimum Output Voltage (Vmin) 230V series: d2.0V to d255V d12.0 1-06 460V series: d4.0V to d510V d24.0 1-07 Output Frequency Upper Limit d1 to d110% d100 1-08 Output Frequency Lower Limit d0 to d100% d0 �1-09 Accel Time 1 d0.1 to d600 Sec d10.0 �1-10 Decel Time 1 d0.1 to d600 Sec d10.0 �1-11 Accel Time 2 d0.1 to d600 Sec d10.0 �1-12 Decel Time 2 d0.1 to d600 Sec d10.0 �1-13 Jog Acceleration / Deceleration Time d0.1 to d600 Sec d10.0 �1-14 Jog Frequency d1.0 Hz to d400 Hz d6.0 d0: Linear Accel/Decel d1: Auto Accel, Linear Decel d2: Linear Accel, Auto Decel d3: Auto Accel/Decel (Set by load) Auto acceleration / deceleration (refer 1-15 d0 d4: Linear Accel; Auto Decel, Stall to Accel/Decel time setting) Prevention during Decel d5: Auto Accel/Decel, Stall Prevention during Decel 1-16 Acceleration S-Curve d0 to d7 d0 1-17 Deceleration S-Curve d0 to d7 d0 d0.0 Jog Decelerating Time 1-18 Jog Decelerating Time Determined by Pr.1-13 d0.0 d0.1 to d600 Group 2 Operation Method Parameters Factory Pr. Explanation Settings NOTE Setting d0: Master Frequency input determined by digital keypad. (record the frequency of power loss and it can do analog overlap plus) d1: Master Frequency determined by analog signal DC 0V-10V (external terminal AVI). (won’t record the frequency of power loss and it can’t do analog Source of Master Frequency overlap plus) 2-00 d0 Command d2: Master Frequency determined by analog signal DC 4mA - 20mA (external terminal AVI). (won’t record the frequency of power loss and it can’t do analog overlap plus) d3: Master Frequency determined by Potentiometer on the digital keypad. (won’t record the frequency of power loss and it can do analog overlap plus) Revision August 2006, SE08, SW V2.61 5-3 Chapter 5 Parameters|VFD-S Series Factory Pr. Explanation Settings NOTE Setting d4: Master Frequency operated by RS-485 serial communication interface and record frequency of power loss. (record the frequency of power loss and it can do analog overlap plus) Source of Master Frequency 2-00 d5: Master Frequency operated by d0 Command RS-485 serial communication interface and won’t record frequency before power loss. (won’t record the frequency of power loss and it can do analog overlap plus) d0: Digital Keypad d1: External terminals. Keypad STOP/RESET enabled. d2: External terminals. Keypad STOP/RESET disabled. Source of Operation 2-01 d3: RS-485 serial communication d0 Command (RJ-11) .Keypad STOP/RESET enabled. d4: RS-485 serial communication (RJ-11). Keypad STOP/RESET disabled. d0: STOP: ramp to stop; E.F.: coast to stop 2-02 Stop Method d0 d1: STOP: coast to stop; E.F.: coast to stop d3: 3KHz d4: 4KHz d5: 5KHz d6: 6KHz 2-03 PWM Carrier Frequency Selections d10 d7: 7KHz d8: 8KHz d9: 9KHz d10: 10KHz d0: Enable forward/reverse 2-04 Motor Direction Control operation d0 d1: Disable reverse operation d0: Decelerate to 0 Hz d1: Coast to stop and display “EF” 2-05 Loss of ACI Signal d0 d2: Continue operation by last frequency command d0: Disable d1: Enable + AVI 2-06 Analog Auxiliary Frequency Operation d0 d2: Enable + ACI Group 3 Output Function Parameters 5-4 Revision August 2006, SE08, SW V2.61 Chapter 5 Parameters|VFD-S Series Factory Pr. Explanation Settings NOTE Setting d0: analog frequency meter 3-00 Analog Output Signal d0 d1: analog current meter �3-01 Analog Output Gain d1 to d200% d100 3-02 Desired Frequency Attained d1.0 to d400 Hz d1.0 3-03 Terminal Count Value d0 to d999 d0 3-04 Preliminary Count Value d0 to d999 d0 Multi-Function Output Terminal 1 3-05 d0: No Function d1 (Photocoupler Output) d1: AC Drive Operational d2: Master Frequency Attained d3: Zero Speed d4: Over Torque Detection d5: Base-Block (B.B.) Indication d6: Low-Voltage Indication d7: Operation Mode Indication d8: Fault Indication d9: Desired Frequency Attained Multi-Function Output Terminal 2 d10: PLC Program Running 3-06 d8 (Relay Output) d11: PLC Program Step Completed d12: PLC Program Completed d13: PLC Program Operation Paused d14: Terminal Count Value Attained d15: Preliminary Count Value Attained d16: AC Motor Drive Ready d17: FWD command Indication d18: REV command Indication Group 4 Input Function Parameters Factory Pr. Explanation Settings NOTE Setting �4-00 Potentiometer Bias Frequency d 0.0 to d 100.0% d0.0 d0: Positive Bias Potentiometer Bias �4-01 d0 d1: Negative Bias Polarity Potentiometer �4-02 d1 to d200 % d100 Frequency Gain d0: Forward Motion Only Potentiometer Reverse 4-03 d0 d1: Reverse Motion enabled Motion Enable d0: No Function d1: FWD/STOP, REV/STOP d2: FWD/REV, RUN/STOP d3: 3-wire Operation Control Mode Multi-Function Input Terminal 1 (M0, d4: E.F. External Fault Input (N.O.) 4-04 d1 M1) d5: E.F. External Fault Input (N.C.) d6: Reset d7: Multi-Step Speed Command 1 d8: Multi-Step Speed Command 2 d9: Multi-Step Speed Command 3 Revision August 2006, SE08, SW V2.61 5-5 Chapter 5 Parameters|VFD-S Series Factory Pr. Explanation Settings NOTE Setting Multi-Function Input Terminal 2 (M2) d10: Jog Operation 4-05 d6 d11: Accel/decel Inhibit Multi-Function Input Terminal 3 (M3) d12: First or Second Acceleration/deceleration Time 4-06 Selection d7 d13: External base block (N.O.) d14: External base block (N.C.) Multi-Function Input Terminal 4 (M4) d15: Up: Increment master frequency 4-07 d16: Down: Decrement master d8 frequency d17: Run PLC Program d18: Pause PLC Program d19: Counter Trigger Signal d20: Counter Reset d21: Select ACI / Deselect AVI d22: PID Function Disabled d23: JOG FWD d24: JOG REV d25: The source of master frequency is AVI. 4-08 Multi-Function Input Terminal 5(M5) d9 d26: The source of master frequency is ACI. d27: Press UP/DOWN key to switch forward/reverse (N.O.) motion d28: Press UP/DOWN key to switch forward/reverse (N.C.) motion d29: M0: 0: RUN 1: STOP, M1: no function, Direction is controlled by keypad d0: Disable 4-09 Line Start Lockout d0 d1: Enable d0: Based on accel/decel time d1: Up frequency according to constant speed, down frequency according to deceleration time 4-10 Up/Down Mode d2: Up frequency according to d3 acceleration time, down frequenc according to constant speed d3: Constant speed Accel/Decel Rate of Change of 4-11 UP/DOWN Operation with Constant 0~1000, unit: 5 Hz/sec d1 Speed Group 5 Multi-Step Speed and PLC Parameters Factory Pr. Explanation Settings NOTE Setting 5-00 1st Step Speed Freq. d0.0 to d400 Hz d0.0 5-01 2nd Step Speed Freq. d0.0 to d400 Hz d0.0 5-6 Revision August 2006, SE08, SW V2.61 Chapter 5 Parameters|VFD-S Series Factory Pr. Explanation Settings NOTE Setting 5-02 3rd Step Speed Freq. d0.0 to d400 Hz d0.0 5-03 4th Step Speed Freq. d0.0 to d400 Hz d0.0 5-04 5th Step Speed Freq. d0.0 to d400 Hz d0.0 5-05 6th Step Speed Freq. d0.0 to d400 Hz d0.0 5-06 7th Step Speed Freq. d0.0 to d400 Hz d0.0 d0: Disable PLC Operation d1: Execute one program cycle d2: Continuously execute program cycles d3: Execute one program cycle step by step 5-07 PLC Mode d0 d4: Continuously execute one program cycle step by step d5: Disable PLC operation, but can set direction of 1st speed to 7th speed 5-08 PLC Forward/ Reverse Motion d0 to d255 (0: FWD 1: REV) d0 5-09 Time Duration of Zero Step Speed d0 to d65500 Sec d0 5-10 Time Duration of 1st Step Speed d0 to d65500 Sec d0 5-11 Time Duration of 2nd Step Speed d0 to d65500 Sec d0 5-12 Time Duration of 3rd Step Speed d0 to d65500 Sec d0 5-13 Time Duration of 4th Step Speed d0 to d65500 Sec d0 5-14 Time Duration of 5th Step Speed d0 to d65500 Sec d0 5-15 Time Duration of 6th Step Speed d0 to d65500 Sec d0 5-16 Time Duration of 7th Step Speed d0 to d65500 Sec d0 Group 6 Protection Parameters Factory Pr. Explanation Settings NOTE Setting d0: Disable 6-00 Over-Voltage Stall Prevention d1 d1: Enable Over-Voltage Stall Prevention Level 115V/230V series: d350 to d410V d390 6-01 460V series: d700 to d820V d780 6-02 Over-Current Stall Prevention Level d20 to d150% d130 d0: Disabled d1: Enabled during constant speed operation. After the over-torque is detected, keep running until OL1 or OL occurs. d2: Enabled during constant speed operation. After the over-torque 6-03 Over-Torque Detection Mode is detected, stop running. d0 d3: Enabled during running and continues before Continuous Output Time Limit (Pr.6-05) is reached d4: Enabled during running. After the over-torque is detected, stop running. 6-04 Over-Torque Detection Level d30 to d200% d150 Revision August 2006, SE08, SW V2.61 5-7 Chapter 5 Parameters|VFD-S Series Factory Pr. Explanation Settings NOTE Setting 6-05 Over-Torque Detection Time d0.1 to d10.0 Sec d0.1 Electronic Thermal Overload Relay 6-06 d0 to d2 d2 Selection Electronic Thermal �6-07 d30 to d600 Sec d60 Characteristic 6-08 Present Fault Record d0: No fault d1: Over current (oc) d2: Over voltage (ov) d3: Over heat (oH) d4: Over load (oL) 6-09 Second Most Recent Fault Record d5: Over load (oL1) d6: External fault (EF) d7: Reserved d0 d8: Reserved d9: Excess current during acceleration (ocA) d10: Excess current during 6-10 Third Most Recent Fault Record deceleration (ocd) d11: Excess current during steady state (ocn) d12: Ground fault (GF) d13: Reserved d14: Low voltage (Lv) d15: CPU failure 1 (cF1) d16: CPU failure 2 (cF2) d17: Base block (b.b.) d18: Overload (oL2) d19: Auto acceleration/deceleration failure (cFA) d20: Software protection enable (codE) d21: Reserved d22: CPU failure (cF3.1) d23: CPU failure (cF3.2) d24: CPU failure (cF3.3) d25: CPU failure (cF3.4) d26: CPU failure (cF3.5) d27: CPU failure (cF3.6) d28: CPU failure (cF3.7) d29: Hardware protection failure (HPF.1) d30: Hardware protection failure (HPF.2) d31: Hardware protection failure (HPF.3) d32: Communication time-out (CE10) d33: Reserved d34: Software error (SErr) d35: Reserved d36: PID error (Pld) d0 d37: Reserved d38: Phase loss (PHL) 5-8 Revision August 2006, SE08, SW V2.61 Chapter 5 Parameters|VFD-S Series Group 7 Motor Parameters Factory Pr. Explanation Settings NOTE Setting �7-00 Motor Rated Current d30 to d120% d85 Motor No-Load Current �7-01 d0 to d90% d50 Torque Compensation �7-02 d0 to d10 d1 �7-03 Slip Compensation d0.0 to d10.0 d0.0 Group 8 Special Parameters Factory Pr. Explanation Settings NOTE Setting 8-00 DC Braking Voltage Level d0 to d30% d0 8-01 DC Braking Time during Start-Up d0.0 to d60.0 Sec d0.0 8-02 DC Braking time during Stopping d0.0 to d60.0 Sec d0.0 8-03 Start-Point for DC Braking d0.0 to d400 Hz d0.0 d0: Operation stops after Momentary Power Loss d1: Operation continues after momentary power loss, speed Momentary Power Loss Operation search starts with the Master 8-04 d0 Selection Frequency reference value d2: Operation continues after momentary power loss, speed search starts with the minimum frequency 8-05 Maximum Allowable Power Loss Time d0.3 to d5.0 Sec d2.0 8-06 B.B. Time for Speed Search d0.3 to d5.0 Sec d0.5 8-07 Current Limit for Speed Search d30 to d200% d150 8-08 Skip Frequency 1 Upper Limit d0.0 to d400 Hz d0.0 8-09 Skip Frequency 1 Lower Limit d0.0 to d400 Hz d0.0 8-10 Skip Frequency 2 Upper Limit d0.0 to d400 Hz d0.0 8-11 Skip Frequency 2 Lower Limit d0.0 to d400 Hz d0.0 8-12 Skip Frequency 3 Upper Limit d0.0 to d400 Hz d0.0 8-13 Skip Frequency 3 Lower Limit d0.0 to d400 Hz d0.0 8-14 Auto Restart After Fault d0 to d10 d0 d0: Enable 8-15 AVR Function d1: Disable d2 d2: Disable when deceleration Software Braking Level 115V/230V series: d350 to d450V d380 8-16 460V series: d700 to d900V d760 8-17 DC Braking Lower Bound Limit d0.0 to d400 Hz d0.0 Group 9 Communication Parameters Revision August 2006, SE08, SW V2.61 5-9 Chapter 5 Parameters|VFD-S Series Factory Pr. Explanation Settings NOTE Setting Communication �9-00 d1 to d254 d1 Address d0: Baud Rate 4800 bps �9-01 Transmission Speed d1 d1: Baud Rate 9600 bps d2: Baud Rate 19200 bps �9-01 Transmission Speed d1 d3: Baud Rate 38400 bps d0: Warn and Keep Operating Transmission Fault d1: Warn and Ramp to Stop �9-02 d0 Treatment d2: Warn and Coast to Stop d3: Keep Operating without Warning d0: Disable �9-03 Time-out Detection d0 d1 to d20: time setting (1 sec increment) d0: 7,N,2 (Modbus, ASCII) d1: 7,E,1 (Modbus, ASCII) d2: 7,O,1 (Modbus, ASCII) d3: 8,N,2 (Modbus, ASCII) Communication �9-04 d0 d4: 8,E,1 (Modbus, ASCII) Protocol d5: 8,O,1 (Modbus, ASCII) d6: 8,N,2 (Modbus, RTU) d7: 8,E,1 (Modbus, RTU) d8: 8,O,1 (Modbus, RTU) Group A PID Parameters Factory Pr. Explanation Settings NOTE Setting d0: Disable PID function d1: Negative PID feedback from external terminal (AVI) 0 to +10V d2: Negative PID feedback from external terminal (ACI) 4 to A-00 Input terminal for PID Feedback 20mA d0 d3: Positive PID feedback from external terminal (AVI) 0 to +10V d4: Positive PID feedback from external terminal (ACI) 4 to 20mA A-01 Gain over PID Detection value d0 to d999 d100 A-02 Proportional Gain (P) d0 to d999 d100 A-03 Integral Time (I) d0 to d999 d100 A-04 Derivative Control (D) d0 to d100 d0 A-05 Upper Bound for Integral Control d0 to d100% d100 A-06 Primary Delay Filter Time d0 to d999 d0 5-10 Revision August 2006, SE08, SW V2.61 Chapter 5 Parameters|VFD-S Series Factory Pr. Explanation Settings NOTE Setting A-07 PID Output Freq. Limit d0 to d110% d100 A-08 Feedback Signal Detection Time d0.0 to d650 seconds d0.0 Treatment of the Erroneous d0: warn and RAMP to stop A-09 d0 Feedback Signals d1: warn and COAST to stop A-10 Sleep Frequency d0.0 to d400Hz d0.0 A-11 Wakeup Frequency d0.0 to d400Hz d0.0 A-12 Sleep Period d0.0 to d650 seconds d0.0 A-13 PID User Defined d0.0 to d400 d0.0 Revision August 2006, SE08, SW V2.61 5-11 Chapter 5 Parameters|VFD-S Series 5.2 Parameter Settings for Applications � Speed Search Related Applications Purpose Functions Parameters Windmill, winding Restart free- Before the free-running motor is 8-06 machine, fan and all running motor completely stopped, it can be restarted 8-07 inertia loads without detection of motor speed. The AC motor drive will auto search motor speed and will accelerate when its speed is the same as the motor speed. � DC Braking before Running Related Applications Purpose Functions Parameters When e.g. windmills, Keep the free- If the running direction of the free- 8-00 fans and pumps rotate running motor at running motor is not steady, please 8-01 freely by wind or flow standstill. execute DC braking before start-up. 8-17 without applying power � Multi-step Operation Related Applications Purpose Functions Parameters 4-04~4-08 Cyclic operation by To control 7-step speeds and duration Conveying machinery multi-step speeds. by simple contact signals. 5-00~5-06 � Switching acceleration and deceleration times Related Applications Purpose Functions Parameters Switching 1-09~1-12 When an AC motor drive drives two or Auto turntable for acceleration and more motors, it can reach high-speed 4-04~4-08 conveying machinery deceleration times but still start and stop smoothly. by external signal � Operation Command Related Applications Purpose Functions Parameters Selecting the Selection of AC motor drive control by 2-01 General application source of control external terminals, digital keypad or 4-04~4-08 signal RS485. 5-12 Revision August 2006, SE08, SW V2.61 Chapter 5 Parameters|VFD-S Series � Two-wire/three-wire Related Applications Purpose Functions Parameters FWD/STOP 4-04~4-08 M0 "Open": Stop, "Close": FWD Run REV/STOP M1 "Open": Stop, "Close":REV Run GND M0 "Open": Stop, "Close": Run To run, stop, RUN/STOP forward and General application M1 "Open": FWD, "Close":REV reverse by external REV/FWD terminals GND 3-wire STOP RUN M0 Run command, Runs when "close" M2 Stop command, stops when "Open" M1 REV/FWD Run selection "Open": FWD Run RUN/FWD "Close": REV Run GND � Frequency Hold Related Applications Purpose Functions Parameters Acceleration/ Hold output frequency during 4-04~4-08 General application deceleration pause Acceleration/deceleration � Auto Restart after Fault Related Applications Purpose Functions Parameters For continuous and 8-14 The AC motor drive can be Air conditioners, reliable operation restarted/reset automatically up to 10 remote pumps without operator times after a fault occurs. intervention � Emergency Stop by DC Braking Related Applications Purpose Functions Parameters AC motor drive can use DC braking 8-00 Emergency stop for emergency stop when quick stop is 8-02 High-speed rotors without brake needed without brake resistor. When 8-03 resistor used often, take motor cooling into consideration. Revision August 2006, SE08, SW V2.61 5-13 Chapter 5 Parameters|VFD-S Series � Over-torque Setting Related Applications Purpose Functions Parameters The over-torque detection level can be 6-03~6-05 set. Once OC stall, OV stall and over- To protect torque occurs, the output frequency Pumps, fans and machines and to will be adjusted automatically. It is extruders have continuous/ suitable for machines like fans and reliable operation pumps that require continuous operation. � Upper/Lower Limit Frequency Related Applications Purpose Functions Parameters When user cannot provide 1-07 Control the motor upper/lower limit, gain or bias from Pump and fan 1-08 speed within external signal, it can be set upper/lower limit individually in AC motor drive. � Skip Frequency Setting Related Applications Purpose Functions Parameters The AC motor drive cannot run at 8-08~8-13 To prevent constant speed in the skip frequency Pumps and fans machine vibrations range. Three skip frequency ranges can be set. � Carrier Frequency Setting Related Applications Purpose Functions Parameters The carrier frequency can be 2-03 General application Low noise increased when required to reduce motor noise. � Keep Running when Frequency Command is Lost Related Applications Purpose Functions Parameters When the frequency command is lost 2-05 For continuous by system malfunction, the AC motor Air conditioners operation drive can still run. Suitable for intelligent air conditioners. 5-14 Revision August 2006, SE08, SW V2.61 Chapter 5 Parameters|VFD-S Series � Output Signal during Running Related Applications Purpose Functions Parameters Signal available to stop braking (brake 3-05~3-06 release) when the AC motor drive is Provide a signal for General application running. (This signal will disappear running status when the AC motor drive is free- running.) � Output Signal in Zero Speed Related Applications Purpose Functions Parameters When the output frequency is lower 3-05~3-06 Provide a signal for than the min. output frequency, a General application running status signal is given for external system or control wiring. � Output Signal at Desired Frequency Related Applications Purpose Functions Parameters When the output frequency is at the 3-05~3-06 Provide a signal for General application desired frequency, a signal is given for running status external system or control wiring. � Over-torque Detection Related Applications Purpose Functions Parameters To protect The over-torque detection level can be 3-05~3-06 Pumps, fans and machines and to set. Once over-torque occurs, a signal 6-04 extruders have continuous/ will occur to prevent the AC motor 6-05 reliable operation drive damage. � Output Signal at Low-voltage Related Applications Purpose Functions Parameters When the voltage between P-N is low 3-05~3-06 Provide a signal for General application voltage, a signal is given for external running status system or control wiring. Revision August 2006, SE08, SW V2.61 5-15 Chapter 5 Parameters|VFD-S Series � Output Signal when Frequency Attained Related Applications Purpose Functions Parameters When the output frequency is at the 3-05~3-06 desired frequency (by frequency Provide a signal for 3-04 General application command), a signal is given for running status 3-10 external system or control wiring (frequency attained). � Output Signal for Base Block Related Applications Purpose Functions Parameters When executing Base Block, a signal 3-05~3-06 Provide a signal for General application is given for external system or control running status wiring. � Overheat Warning for Heat Sink Related Applications Purpose Functions Parameters When heat sink is overheated, it will 3-05~3-06 General application For safety send a signal for external system or control wiring. � Multi-function Analog Output Related Applications Purpose Functions Parameters The value of frequency, output 3-05 Display running current/voltage can be read by General application status connecting a frequency meter or voltage/current meter. 5-16 Revision August 2006, SE08, SW V2.61 Chapter 5 Parameters|VFD-S Series 5.3 Description of Parameter Settings Group 0: User Parameters �This parameter can be set during operation. 0-00 Identity Code of the AC Motor Drive Settings Read Only Factory setting: d# 0-01 Rated Current Display of the AC motor drive Settings Read Only Factory setting: d ##.# � Pr. 0-00 displays the identity code of the AC motor drive. The capacity, rated current, rated voltage and the max. carrier frequency relate to the identity code. Users can use the following table to check how the rated current, rated voltage and max. carrier frequency of the AC motor drive correspond to the identity code. � Pr. 0-01 displays the rated current of the AC motor drive. By reading this parameter the user can check if the AC motor drive is correct. 115V/230V Series KW 0.2 0.4 0.75 1.5 2.2 HP 0.25 0.5 1.0 2.0 3.0 Pr.0-00 d0 d2 d4 d6 d8 Rated Output Current (A) 1.6 2.5 4.2 7.5 11.0 Max. Carrier Frequency 10kHz 460V Series KW 0.4 0.75 1.5 2.2 HP 0.5 1.0 2.0 3.0 Pr.0-00 d3 d5 d7 d9 Rated Output Current (A) 1.5 2.5 4.2 5.5 Max. Carrier Frequency 10kHz 0-02 Parameter Reset Factory Setting: d0 Settings d9 All parameters are reset to factory settings (50Hz, 220V/380V) d10 All parameters are reset to factory settings (60Hz, 220V/440V) � This setting allows the user to return all parameters to the factory default settings. �Start-up Display Selection 0-03 Factory Setting: d0 Settings d0 Display the frequency command value (LED F) d1 Display the actual output frequency (LED H) d2 Multifunction display, see Pr.0-04 d3 Display output current (LED A) Revision August 2006, SE08, SW V2.61 5-17 Chapter 5 Parameters|VFD-S Series d4 Display forward/reverse command (Frd/rEv) 0-04 �Content of Multi-function Display Factory Setting: d0 Settings d0 Display the user-defined unit (u) d1 Display the counter value (C) d2 Display the content of PLC time (1.tt) d3 Display the DC BUS voltage (U) d4 Display the output voltage (E) d5 Display frequency commands of PID (P) d6 Display analog feedback signal value (b) (%) � Display the user-defined unit, where unit = H X Pr.0-5- 0-05 �User Defined Coefficient K Unit: 0. 1 Settings d0.1 to d160 Factory Setting: d1.0 � The coefficient K determines the multiplying factor for the user-defined unit. The display value is calculated as follows: Display value = (output frequency x K) � The display window is only capable of showing three digits, yet you could use Pr.0-05 to create larger numbers. The display windows uses decimal points to signify numbers up to five digits as illustrated in the following: Display Number Represented 999 The absence of a decimal point indicates a three–digit integer. A signal decimal point between the middle and the right-most numbers is a true 99.9 decimal point; it separates ones and tenths as in “30.5” (thirty and one-half). A single decimal point after the right-most numbers is not a true decimal point, 999. instead it indicates that a zero follows the right-most number. For example, the number 1230 would be displayed as “123.” Two decimal points (one between the middle and the right-most numbers, and one after the right-most number) are not true decimal points; instead they indicate 99.9. that two zeros follow the right-most number. For example, the number 34500 would be displayed as “34.5.”. 0-06 Software Version Settings Read Only Display d #.# 5-18 Revision August 2006, SE08, SW V2.61 Chapter 5 Parameters|VFD-S Series 0-07 Password Input Unit: 1 Settings d0 to d999 Factory Setting: d0 � Pr.0-07 and Pr.0-08 work together to provide data security for the AC drive. When Pr.0-08 is set to a value other than 0, a password must be entered to alter the values of parameters. The password is the number set in Pr.0-08, which ranges from 1 to 999. Pr.0-07 is where the password is entered to allow parameter values to be altered. � Display states: d0: no password / correct password has been input d1: parameters are locked Password Set Unit: 1 0-08 Settings d0 to d999 Factory Setting: d0 Display 0 No password set or successful input in Pr. 0-07 1 Password has been set � To set a password to protect your parameter settings. If the display shows 0, no password is set or password has been correctly entered in Pr.0-07. All parameters can then be changed, including Pr.0-08. The first time you can set a password directly. After successful setting of password the display will show 1. Be sure to record the password for later use. To cancel the parameter lock, set the parameter to 0 after inputting correct password into Pr. 0-07. The password consists of min. 1 digits and max. 3 digits. � How to make the password valid again after decoding by Pr.0-07: Method 1: Re-input original password into Pr.0-08 (Or you can enter a new password if you want to use a changed or new one). Method 2: After rebooting, password function will be recovered. Password Decode Flow Chart Revision August 2006, SE08, SW V2.61 5-19 Chapter 5 Parameters|VFD-S Series 0-08 0-07 Displays 0 when Correct Password Incorrect Password entering correct END END password into Pr.0-07. 0-08 0-07 Displays 0 when 3 chances to enter the correct entering correct password. password into 1st time displays "d 1" if Pr.0-07. password is incorrect. 2nd time displays "d 2", if password is incorrect. 3rd time displays " codE" (blinking) If the password was entered incorrectly after three tries, the keypad will be locked. Turn the power OFF/ON to re-enter the password. �Memory Mode Selections Unit: 1 0-09 Settings d0 to d63 Factory Setting: d8 � This parameter is determined to save frequency, operation direction and parameter setting after power off or not. � Setting method: input to this parameter after converting binary 6-bit to decimal. Refer to following two tables for detail. Bit 0 Reserved 0: save frequency Bit 1 1: not save frequency Bit 2 Reserved 0: save direction Bit 3 1: not save direction 0: save parameters (except Pr.0-09 and Pr.0-02) Bit 4 1: not save parameters 0: save Pr.0-09 Bit 5 1: not save Pr. 0-09 5-20 Revision August 2006, SE08, SW V2.61 Chapter 5 Parameters|VFD-S Series bit 5 bit4 Bit 3 bit 1 Setting for Pr. 0-09 0 0 0 1 2 0 0 8 (factory setting) 1 1 10 0 0 16 0 1 18 1 0 24 1 1 26 0 32 0 1 34 0 0 40 1 1 42 1 0 48 0 1 50 1 0 56 1 1 58 � When Pr. 0-09 is set to b5=0, Pr. 0-09 setting will be saved after power on again. � When Pr. 0-02 is set to d10, all parameters (includes Pr.0-09) will be set to factory setting. Revision August 2006, SE08, SW V2.61 5-21 Chapter 5 Parameters|VFD-S Series Group 1: Basic Parameters Maximum Output Frequency (Fmax) Unit: 0.1 1-00 Settings d50.0 to d400 Hz Factory Setting: d60.0 � This parameter determines the AC motor drive’s Maximum Output Frequency. All the AC motor drive frequency command sources (analog inputs 0 to +10V and 4 to 20mA) are scaled to correspond to the output frequency range. 1-01 Maximum Voltage Frequency (Fbase) Unit: 0.1 Settings d10.0 to d400 Hz Factory Setting: d60.0 � This value should be set according to the rated frequency of the motor as indicated on the motor nameplate. Maximum Voltage Frequency determines the v/f curve ratio. For example, if the drive is rated for 460 VAC output and the Maximum Voltage Frequency is set to 60Hz, the drive will maintain a constant ratio of 7.66 V/Hz (460V/60Hz=7.66V/Hz). This parameter value must be equal to or greater than the Mid-Point Frequency (Pr.1-03). 1-02 Maximum Output Voltage (Vmax) Unit: 0.1 Settings 115V/230V seriesd2.0 to d255V Factory Setting: 220.0 460V series d4.0 to d510V Factory Setting: 440.0 � This parameter determines the Maximum Output Voltage of the AC motor drive. The Maximum Output Voltage setting must be smaller than or equal to the rated voltage of the motor as indicated on the motor nameplate. This parameter value must be equal to or greater than the Mid-Point Voltage (Pr.1-04). 1-03 Mid-Point Frequency (Fmid) Unit: 0.1 Settings d1.0 to d400Hz Factory Setting: d1.0 � This parameter sets the Mid-Point Frequency of the V/f curve. With this setting, the V/f ratio between Minimum Frequency and Mid-Point frequency can be determined. This parameter must be equal to or greater than Minimum Output Frequency (Pr.1-05) and equal to or less than Maximum Voltage Frequency (Pr.1-01). 1-04 Mid-Point Voltage (Vmid) Unit: 0.1 Settings 115V/230V seriesd2.0 to d255V Factory Setting: d12.0 460V series d4.0 to d510V Factory Setting: d24.0 5-22 Revision August 2006, SE08, SW V2.61 Chapter 5 Parameters|VFD-S Series � This parameter sets the Mid-Point Voltage of any V/f curve. With this setting, the V/f ratio between Minimum Frequency and Mid-Point Frequency can be determined. This parameter must be equal to or greater than Minimum Output Voltage (Pr.1-06) and equal to or less than Maximum Output Voltage (Pr.1-02). 1-05 Minimum Output Frequency (Fmin) Unit: 0.1 Settings d1.0 to d60.0Hz Factory Setting: d1.0 � This parameter sets the Minimum Output Frequency of the AC drive. This parameter must be equal to or less than Mid-Point Frequency (Pr.1-03). 1-06 Minimum Output Voltage (Vmin) Unit: 0.1 Settings 115V/230V seriesd2.0 to d255V Factory Setting: d12.0 460V series d4.0 to d510V Factory Setting: d24.0 � This parameter sets Minimum Output Voltage of the AC drive. This parameter must be equal to or less than Mid-Point Voltage (Pr.1-04). Voltage Pr.1-02 Pr.1-04 Pr.1-06 Freq. 0 Pr.1-03 Pr.1-00 Pr.1-05 Pr.1-01 Standard V/F Curve 1-07 Output Frequency Upper Limit Unit: 1 Settings d1 to d110% Factory Setting: d100 � This parameter must be equal to or greater than the Output Frequency Lower Limit (Pr.1-08). The Maximum Output Frequency (Pr.1-00) is regarded as 100%. � Output Frequency Upper Limit value = (Pr.1-00 * Pr.1-07)/100. 1-08 Unit: 1 Output Frequency Lower Limit Settings d0 to d100% Factory Setting: d0 � The Upper/Lower Limit is to prevent operation error and machine damage. Revision August 2006, SE08, SW V2.61 5-23 Chapter 5 Parameters|VFD-S Series � If the Upper Limit of Output Frequency is 50Hz and the Maximum Output Frequency is 60Hz, the Maximum Output Frequency will be limited to 50Hz. � If the Lower Limit of Output Frequency is 10Hz, and the Minimum Output Frequency (Pr.1-05) is set at 1.0Hz, then any Command Frequency between 1-10Hz will generate a 10Hz output from the drive. � This parameter must be equal to or less than the Upper Limit of Output Frequency (Pr.1-07). 1-09 �Acceleration Time 1 (Taccel 1) Unit: 0.1 1-10 �Deceleration Time 1 (Tdecel 1) Unit: 0.1 1-11 �Acceleration Time 2 (Taccel 2) Unit: 0.1 1-12 �Deceleration Time 2 (Tdecel 2) Unit: 0.1 Settings d0.1 to d600Sec Factory Setting: d10.0 � Pr.1-9- This parameter is used to determine the time required for the AC drive to ramp from 0 Hz to its Maximum Output Frequency (Pr.1-00). The rate is linear unless S-Curve is “Enabled.” � Pr.1-10. This parameter is used to determine the time required for the AC drive to decelerate from the Maximum Output Frequency (Pr.1-00) down to 0 Hz. The rate is linear unless S- Curve is “Enabled.” � The acceleration/deceleration time 2 determines the time for the AC drive to acceleration/deceleration from 0Hz to Maximum Output Frequency (Pr.1-00) (acceleration/deceleration time 1 is the default). A Multi-Function Input terminal must be programmed to select acceleration/deceleration time 2 and the terminals must be closed to select acceleration/deceleration time 2. See Pr.4-04 to Pr.4-8- � In the diagram shown below, the acceleration/deceleration time of the AC drive is the time between 0 Hz to Maximum Output Frequency (Pr.1-00). Suppose the Maximum Output Frequency is 60 Hz, start-up frequency (Pr.1-05) is 1.0 Hz, and acceleration/deceleration time is 10 seconds. The actual time for the AC drive to accelerate from start-up to 60 Hz is 9.83 seconds and the deceleration time is also 9.83 seconds. 1-13 � Jog Acceleration/Deceleration Time Unit: 0.1Sec Settings d0.1 to d600Sec Factory Setting: d10.0 1-14 � Jog Frequency Unit: 0.1Hz Settings d1.0 to d400Hz Factory Setting: d6.0 5-24 Revision August 2006, SE08, SW V2.61 Chapter 5 Parameters|VFD-S Series � The JOG function can be selected using Multi-function Input terminals (Pr.4-04 to Pr.4-08) if programmed for Jog (d10). When the Jog terminal is “closed”, the AC drive will accelerate from Minimum Output Frequency (Pr.1-05) to Jog Frequency (Pr.1-14). When the Jog terminal “open”, the AC drive will decelerate from Jog Frequency to zero. The acceleration/deceleration time is decided by the Jog acceleration/deceleration time (Pr.1-13). During operation, the AC drive cannot perform Jog command. And during Jog operation, other operation commands cannot be accepted, except command of FORWARD, REVERSE and STOP keys on the digital keypad. Frequency Max. Output freq. Pr.1-00 Jog Freq. Pr.1-14 Time Pr. 1-13 Pr. 1-13 Acceleration Time Deceleration Time Jog operation OFF ON command 1-15 �Auto-Acceleration / Deceleration Factory Setting: d0 Settings d0 Linear Accel/Decel d1 Auto Accel, Linear Decel d2 Linear Accel, Auto Decel d3 Auto Accel/Decel (Set by load) d4 Linear Accel; Auto Decel, Stall Prevention during Decel d5 Auto Accel/Decel, Stall Prevention during Decel � If the auto acceleration/deceleration is selected, the AC drive will acceleration/deceleration in the fastest and smoothest means possible by automatically adjusting the time of acceleration/deceleration. Revision August 2006, SE08, SW V2.61 5-25 Chapter 5 Parameters|VFD-S Series 1-16 Acceleration S-Curve 1-17 Deceleration S-Curve Settings d0 to d7 Factory Setting: d0 � These two parameters allow you to configure whether the acceleration and/or deceleration ramps are linear or S-shaped. The S-curve is enabled when set at d1-d7. Setting d1 offers the quickest S-curve and d7 offers the longest and smoothest S-curve. The AC drive will not follow the acceleration/deceleration time in Pr.1-09 to Pr.1-12. To Disable the S-curve, set Pr.1-16 and Pr.1-17 to d0. � From the diagram shown below, the original setting acceleration/deceleration time will be for reference when the function of the S-curve is enabled. The actual acceleration/deceleration time will be determined based on the S-curve selected (d1 to d7). 1 2 3 4 2 1 3 4 1 2 3 4 Disable S curve Enable S curve Acceleration/deceleration Characteristics 1-18 Jog Decelerating Time Unit: 0.1Sec Settings d0.0 to d600 Factory Setting: d0.0 � When Pr.1-18 is set to d0.0 Jog decelerating time determined by the setting of Pr.1-13 0.1 to 600 sec, Jog decelerating time can be set independently, separates from Pr.1-13. � When Pr.1-18 is set to 0.0, Pr.1-13 determines both Jog acceleration and deceleration time. When Pr.1-18 is set between 0.1 to 600 seconds, which will determine Jog Decelerating Time and Pr.1-13 will only determine Jog Accelerating Time. 5-26 Revision August 2006, SE08, SW V2.61 Chapter 5 Parameters|VFD-S Series Group 2: Operation Method Parameters 2-00 Source of Master Frequency Command Factory Setting: d0 Settings d0 Master Frequency input determined by digital keypad. (record the frequency of power loss and it can do analog overlap plus) d1 Master Frequency determined by analog signal DC 0V-10V (external terminal AVI). (won’t record the frequency of power loss and it can’t do analog overlap plus) d2 Master Frequency determined by analog signal DC 4mA-20mA (external terminal AVI). (won’t record the frequency of power loss and it can’t do analog overlap plus) d3 Master Frequency determined by Potentiometer on the digital keypad. (won’t record the frequency of power loss and it can do analog overlap plus) d4 Master Frequency operated by RS-485 serial communication interface and record frequency of power loss. (record the frequency of power loss and it can do analog overlap plus) d5 Master Frequency operated by RS-485 serial communication interface and won’t record frequency before power loss. (won’t record the frequency of power loss and it can do analog overlap plus) � This parameter sets the Frequency Command Source of the AC drive. � If the Frequency Command Source is external (DC 0 to +10V or 4 to 20mA), please make sure the (AVI) terminal jumper is in the proper position as shown below. � Position of jumper: Please open the top cover. It is at the lower-left corner of the panel. The jumper J1 determines the type of external analog input, either DC voltage signal or current signal. J1 Voltage signal input(0-10V) Current signal input(4-20mA) � When setting analog overlap plus, it needs to set Pr. 2-06 to select AVI or ACI. Revision August 2006, SE08, SW V2.61 5-27 Chapter 5 Parameters|VFD-S Series 2-01 Source of Operation Command Factory Setting: d0 Settings d0 Controlled by the keypad d1 External terminals. Keypad STOP/RESET enabled. d2 External terminals. Keypad STOP/RESET disabled. d3 RS-485 serial communication (RJ-11). Keypad STOP/RESET enabled. d4 RS-485 serial communication (RJ-11). Keypad STOP/RESET disabled. � When the AC drive is controlled by an external source, please refer to parameter group 4 for detailed explanations on related parameter settings. 2-02 Stop Method Factory Setting: d0 Settings d0 STOP: ramp to stop E.F.: coast to stop d1 STOP: coast to stop E.F.: coast to stop � The parameter determines how the motor is stopped when the AC motor drive receives a valid stop command or detects External Fault. Ramp: the AC motor drive decelerates to Minimum Output Frequency (Pr.1-05) according to the deceleration time set in Pr.1-10 or Pr.1-12 and then stops. Coast: the AC motor drive stops the output instantly upon command, and the motor free runs until it comes to a complete standstill. The motor stop method is usually determined by the characteristics of the motor load and how frequently it is stopped. (1) It is recommended to use “ramp to stop” for safety of personnel or to prevent material from being wasted in applications where the motor has to stop after the drive is stopped. The deceleration time has to be set accordingly. (2) If motor free running is allowed or the load inertia is large, it is recommended to select “coast to stop”. For example: blowers, punching machines, centrifuges and pumps. 5-28 Revision August 2006, SE08, SW V2.61 Chapter 5 Parameters|VFD-S Series Frequency Frequency output output frequency frequency motor motor speed speed Time Time stops according to free run to stop operation operation decel eration time command RUN RUN STOP command STOP ramp to stop and free run to stop 2-03 Unit: 1 PWM Carrier Frequency Selections 115V/230V/460V Series Power 0.25 to 3hp (0.2kW to 2.2kW) Setting Range d3 to d10 kHz Factory Setting d10 kHz � This parameter determines the PWM carrier frequency of the AC motor drive. Electromagnetic Current Carrier Heat Acoustic Noise or leakage Wave Frequency Dissipation Noise current Minimal Minimal Minimal Significant 3kHz 10kHz Minimal Significant Significant Significant � From the table, we see that the PWM carrier frequency has a significant influence on the electromagnetic noise, AC motor drive heat dissipation, and motor acoustic noise. 2-04 Motor Direction Control Factory Setting: d0 Settings d0 Enable forward/reverse operation d1 Disable reverse operation � The parameter determines whether the AC drive can operate in the reverse direction. Revision August 2006, SE08, SW V2.61 5-29 Chapter 5 Parameters|VFD-S Series 2-05 Loss of ACI Signal (4-20mA) Factory Setting: d0 Settings d0 Decelerate to 0 Hz d1 Coast to stop and display “EF” d2 Continue operation by last frequency command � This parameter is only effective when the Source of Frequency is commanded by a 4 to 20mA signal. The ACI input is considered lost when the ACI signal falls below 2mA. 2-06 Analog Auxiliary Frequency Operation Factory Setting: d0 Settings d0 Disable d1 Enable + AVI (0~10V) d2 Enable + ACI (4~20mA) � This parameter is used to determinate that the analog signal to overlap is 0~10V (AVI) or 4~20mA (ACI). � To make sure the short PIN of J1 on the panel is correct position before setting this parameter. 5-30 Revision August 2006, SE08, SW V2.61 Chapter 5 Parameters|VFD-S Series Group 3: Output Function Parameters 3-00 Analog Output Signal (AFM) Factory Setting: d0 Settings d0 Analog Frequency Meter (0 to Maximum Output Frequency) d1 Analog Current Meter (0 to 250% of rated AC motor drive current) � This parameter sets the function of the AFM output 0~+10VDC (ACM is common). � The voltage output type for this analog signal is PWM. It needs to read value by the movable coil meter and is not suitable for A/D signal conversion. 3-01 �Analog Output Gain Unit: 1 Settings d1 to d200% Factory Setting: d100 � The parameter sets the voltage range of the analog output signal at terminals AFM, that corresponds with either the output frequency or the output current of the VFD. AFM GND AFM GND +- +- Analog Frequency Meter Analog Current Meter � The analog output voltage is directly proportional to the output frequency of the AC drive. With the factory setting of 100%, the Maximum Output Frequency (Pr.1-00) of the AC drive corresponds to +10VDC analog voltage output. (The actual voltage is about +10VDC, and can be adjusted by Pr.3-01). � The analog output voltage is directly proportional to the output current of the AC drive. With the factory setting of 100%, the 2.5 times rated current of the AC drive corresponds to +10VDC analog voltage output. (The actual voltage is about +10VDC, and can be adjusted by Pr. 3-01) NOTE Voltmeter specification: The sourcing capability of the output is limited to 0.21mA. Sourcing voltage: 10V. Output resistance: 47kΩ. If the meter reads full scale at a voltage less than 10 volts, then Pr.3-01 should be set by the following formula: Pr.3-01 = ((meter full scale voltage)/10) ×100% For example: When using the meter with full scale of 5 volts, adjust Pr.3-01 to 50%. Revision August 2006, SE08, SW V2.61 5-31 Chapter 5 Parameters|VFD-S Series 3-02 Desired Frequency Attained Unit: 0.1 Settings d1.0 to d400 Hz Factory Setting: d1.0 � If a multi-function output terminal is set to function as Desired Frequency Attained (Pr.3-05 or 3-06=d9), then the output will be activated when the programmed frequency is attained. Freq. Detection range Max. Output Detection range + Freq. 4Hz + - 2Hz - Desired Freq. Detection Pr.3-02 range -2Hz Time Preset Freq. Attained indication OFF OFF ON Pr.3-05 to 3-06 Desired Freq. Attained OFF ON OFF Indication Pr.3-05 to 3-06 Desired Freq. Attained & Preset Freq. Attained 3-03 Terminal Count Value Unit: 1 Settings d0 to d999 Factory Setting: d0 � The parameter determines the upper limit value of the internal counter. The internal counter can be triggered by the external terminal (Pr.4-4 to Pr.4-8, d19). Upon completion of counting, the specified output terminal will be activated. (Pr.3-05, Pr.3-06, d14). 3-04 Preliminary Count Value Unit: 1 Settings d0 to d999 Factory Setting: d0 � When the counter value is counted up from “1” to the setting value of this parameter, the corresponding multi-function output terminal which set to d15 as Preliminary Counter Value Attained will be closed. The application can be that closing the multi-function output terminal makes the AC drive operate at low speed until stop before the counting value is going to be attained. � The timing diagram is shown below: 5-32 Revision August 2006, SE08, SW V2.61 Chapter 5 Parameters|VFD-S Series Display (Pr.0-04=d1) 2ms TRG Counter Trigger Signal Multi-function Input Terminal 2ms Preliminary Counter Value Attained Output The width of trigger signal (Pr. 3-04=d3) should not be less than (Pr. 3-05 to Pr. 3-06=d15) 2ms(<250 Hz) Terminal Count Value Attained Output (Pr.3-03=d5) (Pr.3-05 to Pr.3-06=d14) 3-05 Multi-function Output Terminal 1 (Photocoupler output) Factory Setting: d1 3-06 Multi-function Output Terminal 2 (relay output) Factory Setting: d8 Settings d0 to d18 Setting Function Description d0 No Function d1 AC Drive Operational the output terminal will be activated when the drive is running. Master Frequency Attained the output will be activated when the AC drive attains d2 Maximum Output Frequency. d3 Zero Speed the output will be activated when Command Frequency is lower than the Minimum Output Frequency. d4 Over Torque Detection the output will be activated as long as the over-torque is detected. Pr.6-04 determines the Over-Torque detection level. d5 Base-Block (B.B.) Indication the output will be activated when the output of the AC drive is shut off by external Baseblock. d6 Low-Voltage Indication the output will be activated when low voltage is detected. d7 Operation Mode Indication the output will be activated when the operation of the AC drive is controlled by External Control Terminals. d8 Fault Indication the output will be activated when faults occur (oc, ov, oH, oL, oL1, EF, cF3, HPF, ocA, ocd, ocn, GF). d9 Desired Frequency Attained the output will be activated when the desired frequency (Pr.3-02)is attained. Revision August 2006, SE08, SW V2.61 5-33 Chapter 5 Parameters|VFD-S Series Setting Function Description d10 PLC Program Running the output will be activated when the PLC program is running. d11 PLC Program Step the output will be activated for 0.5 sec. when each multi- Completed step speed is attained. d12 PLC Program Completed the output will be activated for 0.5 sec. when the PLC program cycle has completed. d13 PLC Operation Paused the output will be activated when PLC operation is paused. Terminal Count Value counter reaches Terminal Count Value. d14 Attained Preliminary Counter Value counter reaches Preliminary Count Value. d15 Attained d16 AC Motor Drive Ready d17 FWD Command Indication When AC drive receives the command of forward running, it will output immediately no matter AC drive is in the state of run or stop. d18 REV Command Indication When AC drive receives the command of reverse running, it will output immediately no matter AC drive is in the state of run or stop. 5-34 Revision August 2006, SE08, SW V2.61 Chapter 5 Parameters|VFD-S Series Group 4: Input Function Parameters 4-00 � Potentiometer Bias Frequency Unit: 0. 1 Settings d0.0 to d100.0% Factory Setting: d0.0 4-01 � Potentiometer Bias Polarity Factory Setting: d0 Settings d0 Positive Bias d1 Negative Bias 4-02 � Potentiometer Frequency Gain Unit: 1 Settings d1 to d200% Factory Setting: d100 4-03 Potentiometer Reverse Motion Enable Factory Setting: d0 Settings d0 Forward motion only d1 Reverse motion enable (must be negative bias) � Pr.4-00 to Pr.4-03 are used when the source of frequency command is the analog signal (0 to +10V DC or 4 to 20 mA DC). Refer to the following examples. Example 1: The following is the most common method. Set parameter 2-00 to d1 (0 to +10V signal) or d2 (4 to 20mA current signal). Example 2: In this example with the potentiometer set to 0V the Output Frequency is 10 Hz. The mid-point of the potentiometer becomes 40 Hz. Once the Maximum Output Frequency is reached any further increase of the potentiometer will not increase output frequency. Revision August 2006, SE08, SW V2.61 5-35 Chapter 5 Parameters|VFD-S Series Example 3: The example also shows the popular method. The whole scale of the potentiometer can be used as desired. In addition to signals of 0 to 10V and4 to 20mA, the popular voltage signals also include signals of 0 to 5V, 20 to 4mA or that under 10V. Regarding the setting, please refer to the following examples. Example 4: This example shows a potentiometer range of 0 to 5 Volts. Example 5: In this example a 1 volt negative bias is used. In a noise environment, it is advantageous to use negative bias to provide a noise margin (1V in this example). 5-36 Revision August 2006, SE08, SW V2.61 Chapter 5 Parameters|VFD-S Series Example 6: In this example, a negative bias is used to provide a noise margin. Also a potentiometer frequency gain is used to allow the Maximum Output Frequency to be reached. Max. Pr.1-00 Output Freq. Gain adjustment 27 60Hz Factory Settings Pr.1-00=60Hz--Max. output Freq. Pr.4-00=10%--Potentiometer bias freq. Pr.4-01=1 -- Bias polarity It's 0Hz 0 Pr.4-02=111% -- Pot. freq. gain within Pr.4-03=0 -- Forward motion only this 54 Hz range. Calculation of gain 10V 0V 10V 0Hz Pr.4-02=( )X100%=111% Negative 9V 0V Potentiometer Scale 1V 10V bias 6Hz Example 7: In this example, the potentiometer is programmed to run a motor is both forward and reverse direction. A motor will be idle when the potentiometer position is at mid-point of its scale. Using Pr.4-03 will disable the external FWD and REV controls. Max. Output Pr.1-00 Freq. 60Hz 0 FWD FWD. REV. Factory Settings 30Hz Pr.1-00=60Hz--Max. output Freq. 0Hz 0V Pr.4-00=30Hz--Potentiometer bias freq. 5V 10V Pr.4-01=1 -- bias polarity Pr.4-02=200% -- pot. freq. gain 30Hz Pr.4-03=1 -- pot. REV motion enable 60 60 REV Hz 0V 10V 60Hz Potentiometer Scale Example 8: In this example, the option of anti-slope is shown. Anti-slope is used in an application where control of pressure, temperature, or flow is needed. Under a high pressure or flow situation, a sensor will generate a large signal such as 20 mA or 10V. With anti-slope enable, the large signal will slow or stop the AC drive. Revision August 2006, SE08, SW V2.61 5-37 Chapter 5 Parameters|VFD-S Series Max. Output Pr.1-00 Freq. 30 60Hz Factory Settings anti-slope Pr.1-00=60Hz--Max. output Freq. Pr.4-00=60Hz--Potentiometer bias freq. Pr.4-01=1 -- bias polarity Pr.4-02=100% -- pot. freq. gain Pr.4-03=1 -- pot. REV. motion enable 60 0 10V 0V Hz 20mA 4mA 0Hz Potentiometer Scale 0V 10V 4mA 20mA 4-04 Multi-function Input Terminal (M0, M1) Settings d0 to d29 Factory Setting: d1 4-05 Multi-function Input Terminal (M2) Factory Setting: d6 4-06 Multi-function Input Terminal (M3) Factory Setting: d7 4-07 Multi-function Input Terminal (M4) Factory Setting: d8 4-08 Multi-function Input Terminal (M5) Factory Setting: d9 Parameters & Functions table: Value Function Value Function d0 No Function d15 Up: Increment master frequency d1 M0: FWD / STOP, M1: REV / STOP d16 Down: Decrement master frequency d2 M0: RUN / STOP, M1: FWD / REV d17 Run PLC Program 3-Wire Operation Control mode (M0, d3 d18 Pause PLC Program M1, M2) d4 External Fault (Normally Open) d19 Counter Trigger Signal d5 External Fault (Normally Closed) d20 Counter Reset Select ACI / Deselect AVI (the priority is d6 External Reset d21 higher than Pr. 2-00 and d26) d7 Multi-Step Speed Command1 d22 PID function disable d8 Multi-Step Speed Command2 d23 JOG FWD d9 Multi-Step Speed Command3 d24 JOG REV The source of master frequency is AVI. (The d10 Jog operation d25 priority is higher than Pr. 2-00 and d26) Acceleration/Deceleration Speed The source of master frequency is ACI. (The d11 d26 Inhibit priority is higher than Pr. 2-00) First or Second Acceleration or Press UP/DOWN key to switch d12 d27 Deceleration Time Selection forward/reverse (N.O.) motion External Base Block (N.O.) Press UP/DOWN key to switch d13 d28 (Normally Open Contact Input) forward/reverse (N.C.) motion External Base Block (N.C.) M0: 0: RUN 1: STOP, M1: no function, d14 d29 (Normally Close Contact Input) Direction is controlled by keypad 5-38 Revision August 2006, SE08, SW V2.61 Chapter 5 Parameters|VFD-S Series Explanations: d0 Parameter Disable: Enter value (d0) to disable any Multi-Function Input Terminal: M1 (Pr.4-04), M2 (Pr.4-05), M3 (Pr.4- 06), M4 (Pr.4-07) or M5 (Pr.4-08). NOTE The purpose of this function is to provide isolation for unused Multi-Function Input Terminals. Any unused terminals should be programmed to d0 to insure they have no effect on drive operation. d1 Two wire operation: Restricted to Pr.4-04 and external terminals M0, M1. FWD/STOP M0 "Open": Stop, "Close": FWD Run REV/STOP M1 "Open": Stop, "Close":REV Run GND d2 Two wire operation: Restrict to Pr. 4-04 and external terminals M0, M1. M0 "Open": Stop, "Close": Run RUN/STOP M1 "Open": FWD, "Close":REV REV/FWD GND NOTE Multi-function Input Terminal M0 does not have its own parameter designation. M0 must be used in conjunction with M1 to operate two and three wire control. d3 Three Wire Control: Restricted to Pr.4-04 control terminals M0, M1, M2. STOP RUN M0 Run command, Runs when "close" M2 Stop command, stops when "Open" M1 REV/FWD Run selection "Open": FWD Run RUN/FWD "Close": REV Run GND Revision August 2006, SE08, SW V2.61 5-39 Chapter 5 Parameters|VFD-S Series NOTE When value d3 is selected for Pr. 4-04, this will over ride any value entered in Pr.4-05, since Pr.4-05 must be used for three wire control as shown above. d4, d5 External Faults: Parameter values d4, d5 programs Multi-Function Input Terminals: M1 (Pr. 4-04), M2 (Pr. 4-05), M3 (Pr. 4-06), M4 (Pr. 4-07) or M5 (Pr. 4-08) to be External Fault (E.F.) inputs. E.F.(N.O.) Mx "Close": Operation available. setting by d4 E.F(N.C.) Mx "Open":Operation available. setting by d5 GND NOTE When an External Fault input signal is received, the AC drive will stop all output and display “ E.F.” on Digital Keypad, the motor will free run. Normal operation can resume after the External Fault is cleared and the AC drive is reset. d6 External Reset: Parameter value d6 programs a Multi-Function Input Terminal: M1 (Pr.4-04), M2 (Pr.4-05), M3 (Pr.4- 06), M4 (Pr.4-07) or M5 (Pr.4-08) to be an External Reset. RESET Mx "Close": Operation available setting by d6 GND NOTE the External Reset has the same function as the Reset key on the Digital keypad. After external fault such as O.H., O.C. and O.V. are clear, this input can be used to reset the drive. d7, d8, d9 Multi-Step Speed Command: Parameter values d7, d8, d9 programs any three of the following Multi-Function Input Terminals: M1 (Pr.4-04), M2 (Pr.4-05), M3 (Pr.4-06), M4 (Pr.4-07) or M5 (Pr.4-08) for multi-step speed command function. 5-40 Revision August 2006, SE08, SW V2.61 Chapter 5 Parameters|VFD-S Series D7 Multi-step 1 Mx "Close": Operation available Mx "Close": Operation available D8 Multi-step 2 Mx "Close": Operation available D9 Multi-step 3 GND These three inputs select the multi-step speeds defined by Pr.5-00 to Pr.5-06 as shown in the following diagram. Pr.5-07 to Pr.5-16 can also control output speed by programming the AC drive’s internal PLC function. Freq. Pr.5-00 Pr.5-04 Step 1 Step 5 Pr.5-05 Pr.5-01 Step 6 Pr.5-03 Step 2 Step 4 Pr.5-02 Pr.5-06 Step 3 Step 7 Time Master Freq. ON ON ON ON Mx1-GND ON ON ON ON Mx2-GND ON ON ON ON Mx3-GND Operation ON OFF Command d10 Jog Operation Control: Parameter value d10 programs Multi-Function Input Terminal: M1 (Pr.4-04), M2 (Pr.4-05), M3 (Pr.4- 06), M4 (Pr.4-07) or M5 (Pr.4-08) for Jog control. Mx "Close": Operation available d10 jog operation command GND NOTE Jog operation programmed by d10 can only be initiated while the motor is stopped. (Refer to Pr.1-13, Pr.1-14.) d11 Acceleration/Deceleration Speed Inhibit: Parameter value d11 programs Multi-Function Input Terminal: M1 (Pr.4-04), M2 (Pr.4-05), M3 (Pr.4- 06), M4 (Pr.4-07) or M5 (Pr.4-08) for Acceleration/deceleration Inhibit. When the command is received, acceleration and deceleration is stopped and the AC drive maintains a constant speed. Revision August 2006, SE08, SW V2.61 5-41 Chapter 5 Parameters|VFD-S Series Frequency Master Frequency Deceleration Acceleration inhibit inhibit Acceleration Deceleration inhibit inhibit Actual operation frequency Time ON ON ON ON Mx-GND Operation OFF ON command d12 First or Second Acceleration/Deceleration Time Selection: Parameter value d12 programs a Multi-Function Input Terminal: M1 (Pr.4-04), M2 (Pr.4-05), M3 (Pr.4-06), M4 (Pr.4-07) or M5 (Pr.4-08) to control selection of First or Second Acceleration/deceleration time. (Refer to Pr.1-09 to Pr.1-12.) Mx "Close": 2nd Acceleration/Deceleraion "Open": 1st Acceleration/Deceleration Mx set d12 GND Frequency Master Pr. Pr. Pr. Pr. Pr. Pr. Frequency1-09 1-10 1-11 1-12 1-09 1-12 2nd Deceleration 1st 2nd 1st Acceleration/ Acceleration/ Acceleration Deceleration Deceleration Time ON ON Mx-GND operation ON ON ON OFF command d13, d14 External Base Block: Parameter values d13, d14 program Multi-Function Input Terminals: M1 (Pr.4-04), M2 (Pr.4-05), M3 (Pr.4-06), M4 (Pr.4-07) or M5 (Pr.4-08) for external Base Block control. Value d13 is for normally open (N.O.) input, and value d14 is for a normally closed (N.C.) input. 5-42 Revision August 2006, SE08, SW V2.61 Chapter 5 Parameters|VFD-S Series B.B.(N.O.) Mx "Close": Operation available. setting by d13 B.B.(N.C.) Mx "Open":Operation available. setting by d14 GND NOTE When a Base-Block signal is received, the AC drive will stop all output and the motor will free run. When base block control is deactivated, the AC drive will start its speed search function and synchronize with the motor speed, and then accelerate to Master Frequency. External base-block signal Speed synchronization Pr.8-04=d1 detection Output Speed search starts with the frequency reference value Output Pr.8-06 voltage Min. base-block time Speed search operation d15, d16 Increase/Decrease Master Frequency: Parameter values d15, d16 program the Multi-Function Input Terminals: M1 (Pr.4-04), M2 (Pr.4-05), M3 (Pr.4-06), M4 (Pr.4-07) or M5 (Pr.4-08) to incrementally increase/ decrease the Master Frequency each time an input is received. UP Mx "Close": Freq. will increase by one unit. setting by d15 DOWN Mx "Close":Freq. will decrease by one unit. setting by d16 GND d17, d18 PLC Function Control: Parameter value d17 programs Multi-Function Input Terminal: M1 (Pr.4-04), M2 (Pr.4-05), M3 (Pr.4- 06), M4 (Pr.4-07) or M5 (Pr.4-08) to enable the AC drive internal PLC program. Parameter value d18 programs an input terminal to pause the PLC program. Revision August 2006, SE08, SW V2.61 5-43 Chapter 5 Parameters|VFD-S Series PLC operation Mx "Close": Run PLC. setting by d17 Mx "Close":Pause PLC. setting by d18 GND NOTE Pr.5-00 to Pr.5-16 define the PLC program. d19 Counter Trigger: Parameter value d19 programs Multi-Function Input Terminal: M1 (Pr.4-04), M2 (Pr.4-05), M3 (Pr.4- 06), M4 (Pr.4-07) or M5 (Pr.4-08) to increase the AC drive’s internal counter. When an input is received, the counter is increased by 1. Trigger Mx counter value increase by 1 when closed. D19 counter trigger signal input. GND NOTE The Counter Trigger input can be connected to an external Pulse Signal Generator to count a processing step or unit of material. See the diagram below. 5-44 Revision August 2006, SE08, SW V2.61 Chapter 5 Parameters|VFD-S Series d20 Counter Reset: Parameter value d20 programs Multi-Function Input Terminal: M1 (Pr.4-04), M2 (Pr. 4-05), M3 (Pr.4- 06), M4 (Pr.4-07) or M5 (Pr.4-08) to reset the counter. Reset counter Mx "close": reset counter. d20 reset the counter value. GND d21 Select ACI / Deselect AVI: Parameter value d21 allows the user to select the input type ACI or AVI via an external switch. AVI is selected when the contact is open and ACI is selected when the contact is closed. Please note: the use of this feature will override Pr.2-00 programming and the jumper of the front of the drive must be moved to the correct location either across the AVI or ACI pin head. d22 PID function disable: When input ON with this setting, PID function will be disabled. d23 JOG FWD: This function could be operated only when the AC motor drive is stop. The operation direction is forward, can’t be changed and can be stopped by the STOP key on the keypad. When the contact is OFF, the AC motor drive will stop by the JOG decel time. Refer to the Pr.1-13 and Pr. 1-14 for detail. d24 JOG REV: This function could be operated only when the AC motor drive is stop. The operation direction is forward, can’t be changed and can be stopped by the STOP key on the keypad. When the contact is OFF, the AC motor drive will stop by the JOG decel time. Refer to the Pr.1-13 and Pr. 1-14 for detail. d25 The source of master frequency is AVI. (The priority is higher than Pr. 2-00 and d26) d26 The source of master frequency is ACI. (The priority is higher than Pr. 2-00) d27 Press UP/DOWN key to switch forward/reverse (N.O.) motion: When this function is enabled, press key for forward motion and key to REV (N.O.) motion. The keys and will be disabled. d28 Press UP/DOWN key to switch forward/reverse (N.C.) motion: When this function is enabled, press key for forward motion and key to REV (N.C.) motion. The keys and will be disabled. Revision August 2006, SE08, SW V2.61 5-45 Chapter 5 Parameters|VFD-S Series d29 M0: 0: RUN 1: STOP, M1: no function, Direction is controlled by keypad RUN/STOP M0 "Open": Stop, "Close": Run M1 No Function GND 4-09 Line Start Lockout Factory Setting: d0 Settings d0 Disable d1 Enable � When enabled, the AC drive will not start when powered up with run commands applied. To start in Line Start Lockout mode, the AC drive must see the run command go from stop to run after power up. When Line Start Lockout is disable (also known as Auto-Start), the drive will start when powered-up with run commands applied. 4-10 Up/Down Mode Factory Setting: d0 Settings d0 Based on accel/decel time d1 up frequency according to constant speed, down frequency according to deceleration time d2 up frequency according to acceleration time, down frequency according to constant speed d3 Constant speed Accel/Decel Rate of Change of UP/DOWN Operation Unit: 5 4-11 with Constant Speed Settings d0 to d1000 Hz/sec Factory Setting: d1 � This parameter is used to set the acceleration/deceleration speed mode when multi-function terminal is set to up/down frequency. (Pr. 4-04 ~ Pr.4-08, function d15, d16) 5-46 Revision August 2006, SE08, SW V2.61 Chapter 5 Parameters|VFD-S Series Group 5: Multi-step speeds and PLC (Process Logic Control) parameters 5-00 �1st Step Speed Frequency Unit: 0.01 5-01 �2nd Step Speed Frequency Unit: 0.01 5-02 �3rd Step Speed Frequency Unit: 0.01 5-03 �4th Step Speed Frequency Unit: 0.01 5-04 �5th Step Speed Frequency Unit: 0.01 5-05 �6th Step Speed Frequency Unit: 0.01 5-06 �7th Step Speed Frequency Unit: 0.01 Settings d0.0 to d400 Hz Factory Setting: 0.00 � The Multi-Function Input Terminals (refer to Pr.4-04 to 4-08) are used to select one of the AC drive Multi-Step speeds. The speeds (frequencies) are determined by Pr.5-00 to 5-06 shown above. 5-07 PLC Mode Factory Setting: d0 Settings d0 Disable PLC operation d1 Execute one program cycle d2 Continuously execute program cycles d3 Execute one program cycle step by step d4 Continuously execute program cycles step by step st th d5 Disable PLC operation, but can set direction of 1 speed to 7 speed � This parameter selects the mode of PLC operation for the AC drive. The PLC program can be used in lieu of any External Controls, Relays or Switches. The AC drive will change speeds and directions according to the user’s desired programming. � When this parameter is set to d5 and it is running by external multi-speed, the high priority of the operation direction is Pr. 5-08. Example 1 (Pr.5-07 = d1): Execute one cycle of the PLC program. Its relative parameter settings are: st th 1. Pr.5-00 to 5-06: 1 to 7 step speed (sets the frequency of each step speed). 2. Pr.4-04 to 4-08: Multi-Function Input Terminals (set one multi-function terminal as d17- PLC auto-operation). 3. Pr.3-05 to 3-06: Multi-Function Output Terminals (set a Multi-Function Terminal as d10-PLC operation indication, d11-one cycle in PLC auto mode or d12-PLC operation fulfillment attainment). 4. Pr.5-07: PLC mode. st th 5. Pr.5-08: Direction of operation for Master Frequency and1 to 7 step speed. 6. Pr.5-09 to 5-16: operation time setting of Master Frequency and1st to 7th step speed. Revision August 2006, SE08, SW V2.61 5-47 Chapter 5 Parameters|VFD-S Series Frequency Master freq.=5Hz Pr.5-03 5-00=10 Hz 4-07=d17 5-09=10 Sec 60Hz 5-01=20 Hz 3-05=d10 5-10=10 Sec 5-02=40 Hz 3-06=d11 5-11=12 Sec Pr.5-04 5-03=60 Hz 50Hz 5-07=d1 5-12=15 Sec 5-04=50 Hz 5-08=d0 5-13=15 Sec Pr.5-02 5-05=30 Hz 5-14=8 Sec 40Hz 5-06=15 Hz 5-15=17 Sec 5-16=17 Sec Pr.5-05 30Hz Pr.5-01 20Hz Pr.5-06 15Hz Pr.5-00 Master 10Hz Freq. Time 5Hz (Sec) 0Hz 5-16 5-11 5-12 5-13 5-14 5-15 5-10 5-09 Program operation command Program operation output indication Program step complete Program operation completed NOTE The above diagram shows one complete PLC cycle. To restart the cycle, turn the PLC program off and then back on. Example 2 (Pr.5-07 = d2): Continuously executes program cycles The diagram below shows the PLC program stepping through each speed and the automatically starting again. To stop the PLC program, one must either pause the program or turn it off (Refer to Pr.4-05 to 4-08 value d17 and d18). Frequency Master freq.=5Hz 5-03 5-00=10 Hz 60Hz 4-07=d17 5-09=10 Sec 5-01=20 Hz 3-05=d11 5-10=10 Sec 5-04 5-02=40 Hz 3-06=d12 5-11=12 Sec 50Hz 5-03=60 Hz 5-07=d2 5-12=15 Sec 5-04=50 Hz 5-08=d0 5-13=15 Sec 5-02 40Hz 5-05=30 Hz 5-14=8 Sec 5-06=15 Hz 5-15=17 Sec 5-05 5-16=17 Sec 30Hz 5-01 5-00 20Hz 5-06 15Hz 5-00 10Hz 5Hz Time 0Hz (Sec) 5-11 5-12 5-13 5-14 5-15 5-16 5-09 5-10 5-10 5-09 Program step complete Program operation completed 5-48 Revision August 2006, SE08, SW V2.61 Chapter 5 Parameters|VFD-S Series Example 3 (Pr. 5-07 = d3) Execute one cycle step by step: The example shows how the PLC can perform one cycle at a time, within a complete cycle. Each step will use the acceleration/deceleration times in Pr.1-09 to Pr.1-12. It should be noticed that the time each step spends at its intended frequency is diminished, due to the time spent during acceleration/deceleration. Frequency Master freq.=5Hz 5-00=10 Hz 4-07=d17 5-09=10 Sec 5-03 5-01=20 Hz 3-05=d11 5-10=10 Sec 60Hz 5-02=40 Hz 3-06=d12 5-11=12 Sec 5-03=60 Hz 5-07=d3 5-12=15 Sec 5-04 50Hz 5-04=50 Hz 5-08=d0 5-13=15 Sec 5-05=30 Hz 5-14=8 Sec 5-06=15 Hz 5-15=17 Sec 40Hz 5-16=17 Sec 5-05 30Hz 20Hz 5-06 15Hz 10Hz 5Hz 0Hz Time (Sec) t t tt 5-13 5-15 5-16 5-14 5-09 Program step complete Program operation completed Example 4 (Pr. 5-07 =d4) Continuously execute PLC cycles step by step: In this explanation, the PLC program runs continuously step by step. Also shown are examples of steps in the Reverse direction. Frequency Master freq.=5Hz 5-00=10 Hz 4-07=d17 5-09=10 Sec 60Hz 5-01=20 Hz 3-05=d10 5-10=10 Sec 5-02=40 Hz 3-06=d11 5-11=12 Sec 5-03=60 Hz 50Hz 5-07=d4 5-12=15 Sec 5-04=50 Hz 5-08=d68 5-13=15 Sec 5-05=30 Hz 5-14=8 Sec 40Hz 5-06=15 Hz 5-15=17 Sec 5-16=17 Sec FWD 15Hz 10Hz Time 0Hz (Sec) 5-09 t REV 20Hz 30Hz Revision August 2006, SE08, SW V2.61 5-49 Chapter 5 Parameters|VFD-S Series Example 5 (Pr. 5-07 = d1 Execute one cycle of the PLC program): In this example, the PLC program runs continuously. It should be noted that the times of reserve motion may be shorter than expected, due to the acceleration/deceleration times. Frequency Master freq.=5Hz 5-00=10 Hz 4-07=d17 5-09=10 Sec 60Hz 5-01=20 Hz 3-05=d10 5-10=10 Sec 5-02=40 Hz 3-06=d11 5-11=12 Sec 50Hz 5-03=60 Hz 5-07=d1 5-12=15 Sec 5-04=50 Hz 5-08=d68 5-13=15 Sec 5-05=30 Hz 40Hz 5-14=8 Sec 5-06=15 Hz 5-15=17 Sec 5-16=17 Sec FWD 15Hz 10Hz Time 0Hz (Sec) 5-09 REV 20Hz 30Hz * The calculation of time for Pr.5-11, Pr.5-12, Pr.5-15 and Pr.5-16 should be carefully planned. 5-08 PLC Forward/Reverse Motion Unit: 1 Settings d0 to d255 Factory Setting: d0 � This parameter controls the direction of motion for the Multi-Step Speed Pr.5-00 to Pr.5-06 and the Master Frequency. The original direction of Master Frequency will become invalid. NOTE The equivalent 8-bit number is used to program the forward/reverse motion for each of the 8 speed steps (including Master Frequency). The binary notation for the 8-bit number must be translated into decimal notation and then be entered. 0=Forward Weights 1=Reverse Bit 7 6 5 4 3 2 1 0 Director of Master Frequency during PLC Direction of 1st speed for Pr.5-00 Direction of 2nd speed for Pr.5-01 Direction of 3rd speed for Pr.5-02 Direction of 4th speed for Pr.5-03 Direction of 5th speed for Pr.5-04 Direction of 6th speed for Pr.5-05 Direction of 7th speed for Pr.5-06 5-50 Revision August 2006, SE08, SW V2.61 Chapter 5 Parameters|VFD-S Series Weights 0=Forward 1=Reverse Bit 7 6 5 4 3 2 1 0 Direction 0 1 1 0 0 1 0 0 WD Direction of 1st speed for Pr.5-00 =FWD Direction of 2nd speed for Pr.5-01 =REV Direction of 3rd speed for Pr.5-02 = FWD Direction of 4th speed for Pr.5-03 = FWD Direction of 5th speed for Pr.5-04 = FWD Direction of 6th speed for Pr.5-05 = REV Direction of 7th speed for Pr.5-06 = FWD 7 6 5 4 3 2 1 0 The setting value = bit7 x 2 +bit6 x 2 +bit5 x 2 +bit4 x 2 +bit3 x 2 +bit2 x 2 +bit1 x 2 +bit0 x 2 7 6 5 4 3 2 1 0 = 0 x 2 +1 x 2 +0 x 2 +0 x 2 +0 x 2 +1 x 2 +0 x 2 +0 x 2 = 0+64+0+0+0+4+0+0 = 68 Setting Pr.5-08 as d68. 5-09 Time Duration of Zero Step Speed Unit: 1 5-10 Time Duration of 1st Step Speed Unit: 1 5-11 Time Duration of 2nd Step Speed Unit: 1 5-12 Time Duration of 3rd Step Speed Unit: 1 5-13 Time Duration of 4th Step Speed Unit: 1 5-14 Time Duration of 5th Step Speed Unit: 1 5-15 Time Duration of 6th Step Speed Unit: 1 5-16 Time Duration of 7th Step Speed Unit: 1 Settings d0 to d65500 Factory Setting: d0 � Pr.5-10 to Pr.5-16 correspond to operation time of each multi-step speed defined by parameters 5-00 to 5-06. The maximum value of these parameters is 65500 sec., and it’s displayed as d65.5. NOTE If a parameter is set to “d0” (0 Sec), the corresponding step will be skipped. This is commonly used to reduce number of program steps. Revision August 2006, SE08, SW V2.61 5-51 Chapter 5 Parameters|VFD-S Series Group 6: Protection Parameters 6-00 Over-Voltage Stall Prevention Unit: 0.1 Factory Setting: d1 Settings d0 Disable d1 Enable � During deceleration, the motor DC bus voltage may exceed its Maximum Allowable Value due to motor regeneration. When this function is enabled, the AC drive will stop decelerating. Maintaining a constant output frequency when it happens. The AC drive will only resume deceleration when the voltage drops below preset value. NOTE With a moderate inertial load, the over-voltage during deceleration won’t happen, and the drive will stop in programmed time. The AC drive will automatically extend the deceleration time with high inertial loads. If deceleration time is critical for the application, then dynamic braking resistors should be used. Over-Voltage Stall Prevention Level 6-01 Unit: 1 Settings 230V Series d350 to d410V Factory Setting: 390 460V Series d700 to d820V Factory Setting: 780 � During deceleration, the DC bus voltage may exceed its maximum allowable value due to motor regeneration. When this function is enabled, the AC drive will stop decelerating. Maintaining a constant output frequency when it happens. The AC drive will resume deceleration when the voltage drops below preset value. � With a moderate inertial load, the over-voltage during deceleration won’t happen, and the drive will stop in programmed time. The AC drive will automatically extend the deceleration time with high inertial loads. If deceleration time is critical for the application, then dynamic braking resistors should be used. 5-52 Revision August 2006, SE08, SW V2.61 Chapter 5 Parameters|VFD-S Series DC bus voltage Over-voltage Band=20V detection level Pr.6-01 time Output Freq. time Over-voltage Stall Prevention 6-02 Unit: 1 Over-Current Stall Prevention Level Settings d20 to d150% Factory Setting: d130 � A setting of 100% is equal to the Rated Output Current of the drive. � During acceleration and steady-state operation, the AC drive output current may increase abruptly to exceed the value specified by Pr.6-02 due to rapid acceleration or excessive load on the motor. When this function is enabled, the AC drive will decrease. The AC drive will only resume acceleration when the current drops below the level specified by Pr. 6-02. Output current Over-current ON detection Band=5% OFF level Pr.6-02 time Output frequency time Over-current Stall Prevention Level Revision August 2006, SE08, SW V2.61 5-53 Chapter 5 Parameters|VFD-S Series 6-03 Over-Torque Detection Mode (OL2) Factory Setting: d0 Settings d0 Over-Torque detection disabled. d1 Enabled during constant speed operation. After the over-torque is detected, keep running until OL1 or OL occurs. d2 Enabled during constant speed operation. After the over-torque is detected, stop running. d3 Over-Torque detection enabled during running, and continues to run till OL1 or OL. d4 Enabled during running. After the over-torque is detected, stop running. 6-04 Over-Torque Detection Level Unit: 1 Settings d30 to d200% Factory Setting: d150 � This setting is proportional to the Rated Output Current of the drive. 6-05 Over-Torque Detection Time Unit: 0.1 Settings d0.1 to d10.0 sec Factory Setting: d0.1 � If a Multi-Function Output Terminal is set as Over-Torque Detection Indication and the output current exceeds the Over-Torque Detection Level (Pr.6-04, Factory Setting: 150%), the Over- Torque Detection Time (Pr.6-05, Factory setting: 0.1) and the setting of multi-function terminal is Over-Torque Detection Indication, the contact will be “close”. 6-06 Electronic Thermal Overload Relay Selection Factory Setting: d2 Settings 0 Operate with a Standard Motor (self-cooled by fan) 1 Operate with a Special Motor (forced external cooling) 2 Operation disabled � This function is used to protect the motor from overloading or overheating. 6-07 �Electronic Thermal Characteristic Unit: 1 Settings d30 to d600Sec Factory Setting: d60 2 � The parameter determines the time required activating the I t electronic thermal protection 2 function. The graph below shows I t curves for 150% output power for 1 minute. 5-54 Revision August 2006, SE08, SW V2.61 Chapter 5 Parameters|VFD-S Series Operation time(min) 5 60Hz or more 4 50Hz 3 10Hz 2 5Hz 1 Load factor (%) 0 20 40 60 80 100 120 140 160 180 200 6-08 Present Fault Record 6-09 Second Most Recent Fault Record 6-10 Third Most Recent Fault Record Factory Setting: d0 Readings d0 No fault d1 Over-current (oc) d2 Over-voltage (ov) d3 Overheat (oH) d4 Overload (oL) d5 Overload1 (oL1) d6 External fault (EF) d7 Reserved d8 Reserved d9 Current exceeds 2 times rated current during accel. (ocA) d10 Current exceeds 2 times rated current during decel.(ocd) d11 Current exceeds 2 times rated current during steady state operation (ocn) d12 Ground fault (GF) d13 Reserved d14 Low voltage (Lv) d15 CPU failure 1 (cF1) d16 CPU failure 2 (cF2) d17 Base block (b.b.) d18 Overload (oL2) d19 Auto acceleration/deceleration failure (cFA) Revision August 2006, SE08, SW V2.61 5-55 Chapter 5 Parameters|VFD-S Series d20 Software protection enable (codE) d21 Reserved d22 CPU failure (cF3.1) d23 CPU failure (cF3.2) d24 CPU failure (cF3.3) d25 CPU failure (cF3.4) d26 CPU failure (cF3.5) d27 CPU failure (cF3.6) d28 CPU failure (cF3.7) d29 Hardware protection failure (HPF.1) d30 Hardware protection failure (HPF.2) d31 Hardware protection failure (HPF.3) d32 Communication time-out (CE10) d33 Reserved d34 Software error (SErr) d35 Reserved d36 PID error (Pld) d37 Reserved d38 Phase loss (PHL) � Pr.6-08 to 6-10 store records of the three most recent faults that had occurred. Use the reset key to reset the drive when the fault no longer exits. 5-56 Revision August 2006, SE08, SW V2.61 Chapter 5 Parameters|VFD-S Series Group 7: Motor Parameters 7-00 �Motor Rated Current Unit: 1 Settings d30 to d120% Factory Setting: d85 � This parameter will limit the AC drive output current in order to prevent the motor from overheating. �Motor No-load Current 7-01 Unit: 1 Settings d0 to d90% Factory Setting: d50 � The rated current of the AC drive is regarded as 100%. Motor setting of no-load current will effect the slip compensation. The setting value must be less than motor rated current setting Pr.7-00 7-02 �Torque Compensation Unit: 0.1 Settings d0 to d10 Factory Setting: d1 � This parameter may be set so that the AC drive will increase its voltage output during start-up to obtain a higher initial starting torque. 7-03 �Slip Compensation Unit: 0.01 Settings d0.0 to d10.0 Factory Setting: d0.0 � While driving an asynchronous motor, load on the AC drive will increase, causing an increase in slip. This parameter may be used to compensate the nominal slip within a range of 0 to 10. When the output current of the AC drive is greater than the motor no-load current (Pr.7-01), the AC drive will adjust its output frequency according to this parameter. Revision August 2006, SE08, SW V2.61 5-57 Chapter 5 Parameters|VFD-S Series Group 8: Special Parameters 8-00 DC Braking Current Level Unit: 1 Settings d0 to d30% Factory Setting: d0 � This parameter determines the level of DC Braking Voltage Level output to the motor during start-up and stopping. When setting DC Braking Voltage, the Maximum Output Voltage (Pr.1- 02) is regarded as 100%. It is recommended to start with a low DC Braking Voltage Level and then increase until proper holding torque has been attained. 8-01 DC Braking Time during Start-up Unit: 0.1 Settings d0.0 to d60.0 sec Factory Setting: d0.0 � This parameter determines the duration of time that the DC Braking Current will be applied to the motor during the AC drive start-up. 8-02 DC Braking Time during Stopping Unit: 0.1 Settings d0.0 to d60.0 sec Factory Setting: d0.0 � This parameter determines the duration of time that the DC braking voltage will be applied to the motor during stopping. If stopping with DC Braking is desired, then Pr.2-02 must be set to RAMP stop (d0). 8-03 Start-Point for DC Braking Unit: 0.1 Settings d0.0 to d400Hz Factory Setting: d0.0 � This parameter determines the frequency when DC Braking will begin during deceleration. Output Frequency Start-Point for DC Braking Time during 01-05 Stopping Minimum Output Frequency 08-03 Time 08-01 Operation 08-02 Command ON OFF DC Braking Voltage % 5-58 Revision August 2006, SE08, SW V2.61 Chapter 5 Parameters|VFD-S Series � DC Braking during Start-up is used for loads that may move before AC drive starts, such as fans and pumps. These loads may also be moving in the wrong direction. Under such circumstances, DC Braking can be executed to hold the load in position before applying a forward motion. � DC Braking during stopping is used to decrease stopping time and also to hold a stopped load in position. For high inertial loads, a dynamic braking resistor may be needed for quick decelerations. 8-04 Momentary Power Loss Operation Selection Factory Setting: d0 Settings d0 Operation stops after momentary power loss d1 Operation continues after momentary power loss, speed search starts with the Master Frequency reference value d2 Operation continues after momentary power loss, speed search starts with the minimum frequency 8-05 Maximum Allowable Power Loss Time Unit: 0.1 Settings d0.3 to d5.0Sec Factory Setting: d2.0 � During a power loss, if the power loss time is less than the time defined by this parameter, the AC drive will resume operation. If the Maximum Allowable Power Loss Time is exceeded, the AC drive output is then turned off. 8-06 Base Block Speed Search Unit: 0.1 Settings d0.3 to d5.0Sec Factory Setting: d0.5 � When a momentary power loss is detected, the AC drive turns off for a specified time interval determined by Pr.8-06 before resuming operation. This time interval is called Base-Block. This parameter should be set to a value where the residual output voltage is nearly zero, before the drive resumes operation. � This parameter also determines the searching time when performing external Base-Block and fault reset. 8-07 Current Limit for Speed Search Unit: 1 Settings d30 to d200% Factory Setting: d150 Revision August 2006, SE08, SW V2.61 5-59 Chapter 5 Parameters|VFD-S Series � Following a power failure, the AC drive will start its speed search operation, only if the output current is greater than the value determined by Pr.8-07. When the output current is less than that of Pr.8-07, the AC drive output frequency is at a “speed synchronization point”. The drive will start to accelerate or decelerate back to the operating frequency at which it was running prior to the power failure. Maximum Allowable Maximum Power Power Loss Time Allowable Power 08-05 08-05 Input Speed Synchronization Speed Search 08-04=d1 Detection 08-04=d2 Speed search starts Output Speed search starts with with the Master Frequency Min. Output Frequency Frequency Output 08-06 08-06 Voltage Baseblock Time Baseblock Time 8-08 Skip Frequency 1 Upper Limit Unit: 0.1 8-09 Skip Frequency 1 Lower Limit Unit: 0.1 8-10 Skip Frequency 2 Upper Limit Unit: 0.1 8-11 Skip Frequency 2 Lower Limit Unit: 0.1 8-12 Skip Frequency 3 Upper Limit Unit: 0.1 8-13 Skip Frequency 3 Lower Limit Unit: 0.1 Settings d0.0 to d400Hz Factory Setting: d0.0 � These parameters determine Skip frequency. It will cause the AC drive to skip operation at these frequency ranges with continuous frequency output. � Pr.8-9, Pr.8-11, Pr.8-13 are for Lower Bound setting, and the settings should follow as Pr.8-9 ≧Pr.8-11≧Pr.8-13. 8-14 Auto Restart After Fault Unit: 1 Settings d0 to d10 Factory Setting: d0 � After fault occurs (allowable faults: over-current OC, over-voltage OV), the AC drive can be reset/restarted automatically up to 10 times. Setting this parameter to 0 will disable the reset/restart operation after any fault has occurred. When enabled, the AC drive will restart with speed search, which starts at the Master Frequency. 5-60 Revision August 2006, SE08, SW V2.61 Chapter 5 Parameters|VFD-S Series 8-15 Automatic Voltage Regulation (AVR) Factory Setting: d0 Settings d0 AVR function enabled d1 AVR function disabled d2 AVR function disabled when deceleration � AVR function automatically regulates the AC drive output voltage to the Maximum Output Voltage (Pr.1-02). For instance, if Pr.1-02 is set at 200 VAC and the input voltage is at 200V to 264VAC, then the Maximum Output Voltage will automatically be reduced to a maximum of 200 VAC. � Without AVR function, the Maximum Output Voltage may vary between 180V to 264VAC, due to the input voltage varying between 180V to 264 VAC. � Selecting program value d2 enables the AVR function and also disables the AVR function during deceleration. This offers a quicker deceleration. Software Braking Level 8-16 Unit: 1 Settings 230V series: d350 to d450V Factory Setting: d380 460V series: d700to d900V Factory Setting: d760 � During deceleration, the DC-bus voltage will increase due to motor regeneration. When DC bus voltage level exceeds the Software Braking Level, the DC brake output pins (B1, B2) will be activated. 8-17 Lower Bound of DC Braking Start-up Frequency Unit: 0.1 Settings d0.0 to d400 Hz Factory Setting: d0.0 � The setting frequency is lower than Pr.8-17, the DC Braking will not be activated when stops. Revision August 2006, SE08, SW V2.61 5-61 Chapter 5 Parameters|VFD-S Series Group 9: Communication Parameters 9-00 �Communication Address Settings d1 to d254 Factory Setting: d1 � If the AC drive is controlled by RS-485 serial communication, the communication address must be set via this parameter. RS485 Computer d2 d3 d1 S1 S1 S1 9-01 �Transmission Speed Factory Setting: d1 Settings d0 Baud rate 4800 bps (bits / second) d1 Baud rate 9600 bps d2 Baud rate 19200 bps d3 Baud rate 38400 bps � Users can set parameters and control the operation of the AC drive via the RS-485 serial interface of a personal computer. This parameter is used to set the transmission speed between the computer and AC drive. 9-02 �Transmission Fault Treatment Factory Setting: d0 Settings d0 Warn and keep operating d1 Warn and RAMP to stop d2 Warn and COAST to stop d3 No warning and keep operating 5-62 Revision August 2006, SE08, SW V2.61 Chapter 5 Parameters|VFD-S Series 9-03 �Time-out Detection Factory Setting: d0 Settings d0 Disable d1 1 sec d2 2 sec : d20 20 sec � If this function is enabled, the timer will start counting once the first valid Modbus communication signal is received after power-up or reset. The timer will reset to 0 after each valid Modbus communication message is received. If the watchdog timer reaches the value set in Pr. 9-03, the drive will stop its output and display the message "CE10" on the digital keypad. This fault can reset by an external terminal, keypad or a Modbus communication reset command. 9-04 �Communication Protocol Factory Setting: d0 Settings d0 Modbus ASCII mode, protocol <7,N,2> d1 Modbus ASCII mode, protocol <7,E,1> d2 Modbus ASCII mode, protocol <7,O,1> d3 Modbus ASCII mode, protocol <8,N,2> d4 Modbus ASCII mode, protocol <8,E,1> d5 Modbus ASCII mode, protocol <8,O,1> d6 Modbus RTU mode, protocol <8,N,2> d7 Modbus RTU mode, protocol <8,E,1> d8 Modbus RTU mode, protocol <8,O,1> � 1. Computer Control 1: +EV 2: GND 3: SG- 4: SG+ 6 1 � There is a built-in RS-485 serial interface, marked (RJ-11 Jack) on the control terminal block, for VFD-S Series. The pins are defined above. Each VFD-S AC drive has a pre- assigned communication address specified by Pr. 9-00. The computer then controls each AC drive according to its communication address. � VFD-S can be setup to communicate on Modbus networks using one of the following modes: ASCII (American Standard Code for Information Interchange) or RTU (Remote Revision August 2006, SE08, SW V2.61 5-63 Chapter 5 Parameters|VFD-S Series Terminal Unit). Users can select the desired mode along with the serial port communication protocol in Pr. 9-04. �Code Description: ASCII mode: Each 8-bit data is the combination of two ASCII characters. For example, a 1-byte data: 64 Hex, shown as ‘64’ in ASCII, consists of ‘6’ (36Hex) and ‘4’ (34Hex). Character ‘0’ ‘1’ ‘2’ ‘3’ ‘4’ ‘5’ ‘6’ ‘7’ ASCII code 30H 31H 32H 33H 34H 35H 36H 37H Character ‘8’ ‘9’ ‘A’ ‘B’ ‘C’ ‘D’ ‘E’ ‘F’ ASCII code 38H 39H 41H 42H 43H 44H 45H 46H RTU mode: Each 8-bit data is the combination of two 4-bit hexadecimal characters. For example, 64 Hex. � 2. Data Format 2.1 10-bit character frame (For 7-bit character): ( 7.N.2) Start Stop Stop 5 01 2 34 6 bit bit bit 7-bit character 10-bit character frame ( 7.E.1) Start Even Stop 0 12 34 56 bit parity bit 7-bit character 10-bit character frame ( 7.O.1) Start Odd Stop 01 2 34 56 bit parity bit 7-bit character 10-bit character frame 2.2 11-bit character frame (For 8-bit character): 5-64 Revision August 2006, SE08, SW V2.61 Chapter 5 Parameters|VFD-S Series ( 8.N.2 ) Start Stop Stop 01 2 34 56 7 bit bit bit 8-bit character 11-bit character frame ( 8.E.1 ) Start Even Stop 01 2 34 5 6 7 parity bit bit 8-bit character 11-bit character frame ( 8.O.1 ) Odd Start Stop 01 2 34 5 6 7 parity bit bit 8-bit character 11-bit character frame � 3. Communication Protocol 3.1 Communication Data Frame: ASCII mode: STX Start character ‘:’ (3AH) ADR 1 Communication address: 8-bit address consists of 2 ASCII codes ADR 0 CMD1 Command code: CMD0 8-bit command consists of 2 ASCII codes Contents of data: DATA (n-1) n x 8-bit data consist of 2n ASCII codes. ……. n <= 25,maximum of 50 ASCII codes DATA 0 LRC CHK 1 LRC check sum: LRC CHK 0 8-bit check sum consists of 2 ASCII codes END1 End characters: END1= CR (0DH), END0= LF (0AH) END0 RTU mode: START A silent interval of more than 10 ms ADR Communication address: 8-bit address CMD Command code: 8-bit command DATA (n-1) Contents of data: ……. n x 8-bit data, n<= 25 DATA 0 CRC CHK Low CRC check sum: CRC CHK 16-bit check sum consists of 2 8-bit characters High END A silent interval of more than 10 ms Revision August 2006, SE08, SW V2.61 5-65 Chapter 5 Parameters|VFD-S Series 3.2 ADR (Communication Address) Valid communication addresses are in the range of 0 to 254. A communication address equal to 0, means broadcast to all AC drives (AMD). In this case, the AMD will not reply any message to the master device. 00H: broadcast to all AC drives 01H: AC drive of address 01 0FH: AC drive of address 15 10H: AC drive of address 16 : FEH: AC drive of address 254 For example, communication to AMD with address 16 decimal (10H): ASCII mode: Address=’1’,’0’ => ‘1’=31H, ‘0’=30H RTU mode: Address=10H 3.3 CMD (Command code) and DATA (data characters) The format of data characters depends on the command code. The available command codes are described as followed: Command code: 03H, read N words. The maximum value of N is 12. For example, reading continuous 2 words from starting address 2102H of AMD with address 01H. ASCII mode: Response message: Command message: STX ‘:’ STX ‘:’ ADR 1 ‘0’ ADR 1 ‘0’ ADR 0 ADR 0 ‘1’ ‘1’ ‘0’ ‘0’ CMD 1 CMD 1 ‘3’ CMD 0 CMD 0 ‘3’ ‘2’ Number of data ‘0’ (Count by byte) Starting data ‘1’ ‘4’ address ‘0’ ‘1’ Content of starting ‘2’ ‘7’ address ‘0’ ‘7’ 2102H Number of data ‘0’ ‘0’ (count by word) ‘0’ ‘0’ ‘2’ Content of address ‘0’ 2103H LRC CHK 1 ‘D’ ‘0’ LRC CHK 0 ‘7’ ‘0’ END 1 CR LRC CHK 1 ‘7’ END 0 LF LRC CHK 0 ‘1’ END 1 CR END 0 LF 5-66 Revision August 2006, SE08, SW V2.61 Chapter 5 Parameters|VFD-S Series RTU mode: Command message: Response message: ADR 01H ADR 01H CMD 03H CMD 03H Starting data 21H Number of data 04H address (count by byte) 02H Number of data 00H Content of address 17H (count by word) 2102H 02H 70H CRC CHK Low 6FH Content of address 00H 2103H CRC CHK High F7H 00H CRC CHK Low FEH CRC CHK High 5CH (2) 06H: single write, write single data to register. Example: writing data 6000(1770H) to register 0100H. AMD address is 01H. ASCII mode: Command message: Response message: STX ‘:’ STX ‘:’ ADR 1 ‘0’ ADR 1 ‘0’ ADR 0 ‘1’ ADR 0 ‘1’ CMD 1 ‘0’ CMD 1 ‘0’ CMD 0 CMD 0 ‘6’ ‘6’ ‘0’ ‘0’ ‘1’ ‘1’ Data address Data address ‘0’ ‘0’ ‘0’ ‘0’ ‘1’ ‘1’ ‘7’ ‘7’ Data content Data content ‘7’ ‘7’ ‘0’ ‘0’ LRC CHK 1 ‘7’ LRC CHK 1 ‘7’ LRC CHK 0 ‘1’ LRC CHK 0 ‘1’ END 1 CR END 1 CR END 0 LF END 0 LF RTU mode: Response message: Command message: ADR 01H ADR 01H CMD 06H CMD 06H 01H 01H Data address Data address 00H 00H 17H 17H Data content Data content 70H 70H CRC CHK Low 86H CRC CHK Low 86H CRC CHK High 22H CRC CHK High 22H (3) Command code: 10H, write n word, n<=12 For example, writing 6000(1770H) to Pr 5-00 (address 0500H) and1000(03E8H) to Pr 5-01 (address 0501H) with slave address 01H. Revision August 2006, SE08, SW V2.61 5-67 Chapter 5 Parameters|VFD-S Series ASCII Mode: Command message: Response message: STX ‘:’ STX ‘:’ ADR 1 ‘0’ ADR 1 ‘0’ ADR 0 ‘1’ ADR 0 ‘1’ CMD1 ‘1’ CMD1 ‘1’ CMD0 ‘0’ CMD0 ‘0’ Starting Data address‘0’ Starting Data ‘0’ address ‘5’ ‘5’ ‘0’ ‘0’ ‘0’ ‘0’ Number of data ‘0’ Number of data ‘0’ (count by word) (count by word) ‘0’ ‘0’ ‘0’ ‘0’ ‘2’ ‘2’ Number of data ‘0’ LRC CHK 1 ‘E’ (count by byte) ‘4’ LRC CHK 0 ‘8’ Data content of ‘1’ END1 CR address 0500H ‘7’ END0 LF ‘7’ ‘0’ Data content of ‘0’ address 0501H ‘3’ ‘E’ ‘8’ LRC CHK 1 ‘7 LRC CHK 0 ‘2 END1 CR END0 LF RTU mode: Command message: Response message: ADR 01H ADR 01H CMD 10H CMD 10H Starting Data address 05H Starting Data address05H 00H 00H Number of data 00H Number of data 00H (count by word) 02H (count by word) 02H Number of data 04H CRC CHK Low 41H (count by Byte) CRC CHK High 04H Data content of address 0500H17H 70H Data content of address 0501H03H E8H CRC CHK Low C8H CRC CHK High 2EH 3.4 Check sum 5-68 Revision August 2006, SE08, SW V2.61 Chapter 5 Parameters|VFD-S Series ASCII mode: LRC (Longitudinal Redundancy Check) is calculated by summing up, module 256, the values of the bytes from ADR1 to last data character then calculating the hexadecimal representation of the 2’s-complement negation of the sum. For example, reading 1 word from address 0401H of the AC drive with address 01H STX ‘:’ ADR 1 ‘0’ ADR 0 ‘1’ CMD1 ‘0’ CMD0 ‘3’ Starting data address ‘0’ ‘4’ ‘0’ ‘1’ Number of data ‘0’ ‘0’ ‘0’ ‘1’ LRC CHK 1 ‘F’ LRC CHK 0 ‘6’ END1 CR END0 LF 01H+03H+04H+01H+00H+01H=0AH, the 2’s-complement negation of 0AH is F6H. RTU mode: ADR 01H CMD 03H Starting address 21H 02H Number of data 00H (count by word) 02H CRC CHK Low 6FH CRC CHK High F7H CRC (Cyclical Redundancy Check) is calculated by the following steps: Step 1: Load a 16-bit register (called CRC register) with FFFFH. Step 2: Exclusive OR the first 8-bit byte of the command message with the low order byte of the 16-bit CRC register, putting the result in the CRC register. Step 3: Examine the LSB of CRC register. Step 4: If the LSB of CRC register is 0, shift the CRC register one bit to the right with MSB zero filling, then repeat step 3. If the LSB of CRC register is 1, shift the CRC register one bit to the right with MSB zero filling, Exclusive OR the CRC register with the polynomial value A001H, then repeat step 3. Revision August 2006, SE08, SW V2.61 5-69 Chapter 5 Parameters|VFD-S Series Step 5: Repeat step 3 and 4 until eight shifts have been performed. When this is done, a complete 8-bit byte will have been processed. Step 6: Repeat step 2 to 5 for the next 8-bit byte of the command message. Continue doing this until all bytes have been processed. The final contents of the CRC register are the CRC value. When transmitting the CRC value in the message, the upper and lower bytes of the CRC value must be swapped, i.e. the lower order byte will be transmitted first. The following is an example of CRC generation using C language. The function takes two arguments: Unsigned char* data � a pointer to the message buffer Unsigned char length � the quantity of bytes in the message buffer The function returns the CRC value as a type of unsigned integer. Unsigned int crc_chk(unsigned char* data, unsigned char length){ int j; unsigned int reg_crc=0xFFFF; while(length--){ reg_crc ^= *data++; for(j=0;j<8;j++){ if(reg_crc & 0x01){ /* LSB(b0)=1 */ reg_crc=(reg_crc>>1) ^ 0xA001; }else{ reg_crc=reg_crc >>1; } } } return reg_crc; } 3.5 Address list The contents of available addresses are shown as below: Content Address Functions AC drive ggnnH gg means parameter group, nn means parameter number, for Parameters example, the address of Pr 4-01 is 0401H. Referencing to chapter 5 for the function of each parameter. When reading parameter by command code 03H, only one parameter can be read at one time. 5-70 Revision August 2006, SE08, SW V2.61 Chapter 5 Parameters|VFD-S Series Content Address Functions Command 2000H Bit 0-1 00: No function 01: Stop 10: Run 11: Jog + Run Bit 2-3 Not used 00: No function 01: FWD Bit 4-5 10: REV 11: Change direction Bit 6-15 Not used 2001H Freq. command 2002H Bit 0 1: EF (external fault) on Bit 1 1: Reset Bit 2-15 Not used Status 2100H Error code: monitor 0: No errors occurred Read only 1: Over-current (oc) 2: Over-voltage (ov) 3: Overheat (oH) 5: Overload1 (oL1) 6: External fault (EF) 7: Not used 8: Not used 9: Current exceeds 2 times rated current during acceleration (ocA) 10: Current exceeds 2 times rated current during deceleration (ocd) 11: Current exceeds 2 times rated current during steady state operation (ocn) 12: Ground Fault (GF) 13: Reserved 14: Low voltage (Lv) 15: CPU failure 1 (cF1) 16: CPU failure 2 (cF2) 17: Base block 18: Overload (oL2) 19: Auto acceleration/deceleration failure (cFA) 20: Software protection enable (codE) 21: Reserved 22: CPU failure (cF3.1) 23: CPU failure (cF3.2) 24: CPU failure (cF3.3) 25: CPU failure (cF3.4) 26: CPU failure (cF3.5) 27: CPU failure (cF3.6) 28: CPU failure (cF3.7) 29: Hardware protection failure (HPF.1) 30: Hardware protection failure (HPF.2) 31: Hardware protection failure (HPF.3) 32: CE 10 33: Reserved 34: Software error (SErr) Revision August 2006, SE08, SW V2.61 5-71 Chapter 5 Parameters|VFD-S Series Content Address Functions 35: Reserved 36: PID error (Pld) 37: Reserved 38: Phase loss (PHL) 2101H Status of AC Drive 00: RUN LED light off, STOP LED light up 01: RUN LED blink, STOP LED light up Bit 0-1 10: RUN LED light up, STOP LED blink 11: RUN LED light up, STOP LED light off Bit 2 01: Jog active 00: REV LED light off, FWD LED light up 01: REV LED blink, FWD LED light up Bit 3-4 10: REV LED light up, FWD LED blink 11: REV LED light up, FRD LED light off Bit 5-7 Not used Bit 8 1: Main freq. Controlled by communication Bit 9 1: Main freq. Controlled by external terminal 1: Operation command controlled by communication Bit 10 Bit 11 1: Parameters have been locked Bit 12-15 Not Used 2102H Frequency command F (XXX.XX) 2103H Output Frequency H (XXX.XX) 2104H Output Current A (XXX.XX) 2105H DC-BUS Voltage U (XXX.XX) 2106H Output Voltage E (XXX.XX) 2107H Step number of Multi-Step Speed Operation 2108H Step number of PLC operation 2109H Time of PLC Operation 210AH Counter Value 3.6 Exception response: The AC motor drive is expected to return a normal response after receiving command messages from the master device. The following depicts the conditions when no normal response is replied to the master device. The AC motor drive does not receive the messages due to a communication error; thus, the AC motor drive has no response. The master device will eventually process a timeout condition. The AC motor drive receives the messages without a communication error, but cannot handle them. An exception response will be returned to the master device and an error message “CExx” will be displayed on the keypad of AC motor drive. The xx of “CExx” is a decimal code equal to the exception code that is described below. In the exception response, the most significant bit of the original command code is set to 1, and an exception code which explains the condition that caused the exception is returned. 5-72 Revision August 2006, SE08, SW V2.61 Chapter 5 Parameters|VFD-S Series Example of an exception response of command code 06H and exception code 02H: ASCII mode: RTU mode: STX ‘:’ ADR 01H ADR 1 ‘0’ CMD 86H ADR 0 ‘1’ Exception code 02H CMD1 ‘8’ CRC CHK Low C3H CMD0 ‘6’ CRC CHK High A1H ‘0’ Exception code ‘2’ LRC CHK 1 ‘7’ LRC CHK 0 ‘7’ END1 CR END0 LF The explanation of exception codes: Exception Meaning code Illegal command code: The command code received in the command 1 message is not available for the AC drive. Illegal data address: The data address received in the command 2 message is not available for the AC drive. Illegal data value: The data value received in the command message 3 is not available for the AC drive. Slave device failure: The AC drive is unable to perform the requested 4 action. The AC drive receives the messages, but detects a communication error, thus, no response is returned, but there will be error message “CExx” displayed on the keypad of AC drive. The master device will eventually process a timeout condition. The xx of “CExx” is a decimal code, the meaning of the error message is below: Error Meaning message 5 eserved AC drive busy: The time interval between commands is too short. Please keep an 6 interval of 10ms at least after the return of a command. If no command returned, please keep a 10ms interval at least for the same reason. 7 Reserved 8 Reserved 9 Check Sum Error: Check if the Check Sum is correct. Watchdog Timer: The timer will reset to 0 after each valid Modbus 10 communication message is received. 11 Frame Error: Check if the Baud rate complies with the data format. 12 The command message is too short. 13 Command message length is out of range. The command messages include the data that does not belong to ‘0’ to 14 ‘9’, ‘A’ to ‘F except starting and end character (only for Modbus ASCII mode). Revision August 2006, SE08, SW V2.61 5-73 Chapter 5 Parameters|VFD-S Series 3.7 Communication program of PC: The following is a simple example of how to write a communication program for Modbus ASCII mode on a PC in C language. #include #include #include #include #define PORT 0x03F8 /* the address of COM1 */ /* the address offset value relative to COM1 */ #define THR 0x0000 #define RDR 0x0000 #define BRDL 0x0000 #define IER 0x0001 #define BRDH 0x0001 #define LCR 0x0003 #define MCR 0x0004 #define LSR 0x0005 #define MSR 0x0006 unsigned char rdat[60]; /* read 2 data from address 2102H of AC drive with address 1 */ unsigned char tdat[60]={':','0','1','0','3','2','1','0',’2', '0','0','0','2','D','7','\r','\n'}; void main(){int i; outportb(PORT+MCR,0x08); /* interrupt enable */ outportb(PORT+IER,0x01); /* interrupt as data in */ outportb(PORT+LCR,(inportb(PORT+LCR) | 0x80)); /* the BRDL/BRDH can be access as LCR.b7==1 */ outportb(PORT+BRDL,12); /* set baudrate=9600, 12=115200/9600*/ outportb(PORT+BRDH,0x00); outportb(PORT+LCR,0x06); /* set protocol, <7,N,2>=06H, <7,E,1>=1AH, <7,O,1>=0AH, <8,N,2>=07H, <8,E,1>=1BH, <8,O,1>=0BH */ for(i=0;i<=16;i++){ while(!(inportb(PORT+LSR) & 0x20)); /* wait until THR empty */ outportb(PORT+THR,tdat[i]); /* send data to THR */ } i=0; while(!kbhit()){ if(inportb(PORT+LSR) & 0x01){ /* b0==1, read data ready */ rdat[i++]=inportb(PORT+RDR); /* read data form RDR */ } } } 5-74 Revision August 2006, SE08, SW V2.61 Chapter 5 Parameters|VFD-S Series Group A: PID Control A-00 Input Terminal for PID Feedback Factory Setting: d0 Settings d0 Disable d1 Negative PID feedback from external terminal (AVI) 0 to +10V d2 Negative PID feedback from external terminal (ACI) 4 to 20mA d3 Positive PID feedback from external terminal (AVI) 0 to +10V d4 Positive PID feedback from external terminal (ACI) 4 to 20mA � Select an input terminal to serve as the PID feedback location. Please verify the feedback location is different from the Frequency Set Point location and J1 for selecting ACI or AVI must be in the correct position. (Refer to Pr. 2-00 for detail) � Negative feedback = Positive target value – detection value. Positive feedback = Negative target value + detection value. A-01 Gain over PID Detection value Settings d0 to d999 (d100 means gain value is 1) Factory Setting: d100 � To adjust feedback detective gain value. It is used to adjust target value error. A-02 Proportional Gain (P) Unit: 1 Settings d0 to d999% (d0: disable) (d100 means Factory Setting: d100 gain value is 1) � This parameter is used to determinate error gain. If I = 0 and D = 0, doing proportional gain operation. A-03 Integral Time (I) Unit: 1 Settings d0 to d999 Factory Setting: d100 d0 Disable � When this parameter is defined to gain is 1 and error value is fixed, integral value is equal to error value as the setting of integral time is attained. A-04 Derivative Control (D) Unit: 1 Settings d0 to d100 Factory Setting: d0 d0 Disable Revision August 2006, SE08, SW V2.61 5-75 Chapter 5 Parameters|VFD-S Series � When this parameter is set to gain =1, PID output is Derivative time. At this time, error value – error value of the preceding item= additional respond speed and it is easy to have over compensation situation. A-05 Upper Bound for Integral Control Unit: 1 Settings d0 to d100% Factory Setting: d100 � This parameter determines the Upper Bound for Integral Control while operating in the PID feedback loop. (Limit = 1-00×A-05 %). During a fast Integration response, it is possible for the frequency to spike beyond a reasonable point. This parameter will limit this frequency spike. A-06 Unit: 2 msec Primary Delay Filter Time Settings d0 to d999 Factory Setting: d0 � Primary Delay Filter Time will slow down oscillation of the system. � A setting of d0 disables this function. A-07 Unit: 1 PID Output Frequency Limit Settings d0 to d110% Factory Setting: d100 � This parameter determines the limit of the PID output frequency. If this parameter is set to 110%, then the maximum output frequency while in the PID operation will be (110% x Pr.01- 00) 66Hz. Feedback Signal Detection Time A-08 Unit: 0.1 Settings d0.0 to d650 seconds Factory Setting: d0.0 � This parameter defines the detection time for the loss of a feedback analog signal. The drive will follow the operating procedure programmed in Pr.A-09 if the feedback signal is lost for more than the time set in Pr. A-08. � A setting of 0.0 disables this function. A-09 Treatment of the Erroneous Feedback Signals Factory Setting: d0 Settings d0 Warning and RAMP to stop d1 Warning and COAST to stop 5-76 Revision August 2006, SE08, SW V2.61 Chapter 5 Parameters|VFD-S Series � This parameter selects the operation of the drive upon a loss of PID feedback signal. Sleep Frequency A-10 Unit: 0.1 Settings d0.0 to d400Hz Factory Setting: d0.0 A-11 Wakeup Frequency Unit: 0.1 Settings d0.0 to d400Hz Factory Setting: d0.0 A-12 Sleep Period Unit: 0.1 Settings d0.0 to d650 seconds Factory Setting: d0.0 � These parameters determine sleep functions of the AC drive. If the command frequency falls below the sleep frequency, for the specified time in Pr. A-12, then the drive will shut off the output and wait until the command frequency rises above Pr. A-11. Please see the below diagram. Actual running Frequency Command output frequency A-11 Wakeup Frequency A-10 Sleep Frequency Sleep Period 0Hz A-12 Sleep Function A-13 PID User Defined Unit: 0.1 Settings d0.0 to d400 Factory Setting: d0.0 � When parameter A-13 is set to 0, what F and H display is the actual value of setting frequency and output frequency. When this parameter is not set to 0, the display value of F and H = actual value ¯A-13/1-00. To set frequency with panel, communication, VR, AVI or ACI need to set according to the display value. For example, when 1-00=60.0Hz, if A-13 is set to 30.0 Hz, it means when the actual value of frequency is 30.00 Hz, the display value will be 15.0 Hz . If you want to let drive run at 10.0Hz, the frequency command must be 5.0 Hz. But Revision August 2006, SE08, SW V2.61 5-77 Chapter 5 Parameters|VFD-S Series st the setting frequency of parameters, such as Max. operation frequency, 1 speed and etc., they are still needed to set with actual value. PID Frequency + One-Time Integration's + Output + Target Delay Upper P I Command Value Bound A-06 A-02 A-03 Limit Frequency + A-07 A-05 Frequency D Command A-04 Detection Output Value Value A-00 Gain A-01 If the input range of sensor is 0~SI_max, output range is SO_min~SO_max and then SI_max Input Per output SO_max-SO_min is , set drive input to sensor output Set input range of drive is D_range= 10V(0~10V) or 16mA (4~20mA) that correspond to 0~1-00Hz 1-00 Output Per input D_range and then will be Display value of F, H Actual value According to the display value of F and H = actual value ¯A-13/1-00, and then =A-13/1-00. If you want the result to be display value = sensor output and actual value = drive output, SI_max A-01 X SO_max-SO_min 100 SI_max A-13 A-01 = A-13 = X XD_range 1-00 1-00 SO_max-SO_min 100 D_range and then Example: Sensor: 0~6 psi input corresponds to 0~5V output drive AVI: 0~10V input corresponds to 0~60Hz, A- 01=100 6 100 A-13 12 = X X10 = 5-0 100 5-78 Revision August 2006, SE08, SW V2.61 Chapter 6 Fault Code Information The AC motor drive has a comprehensive fault diagnostic system that includes several different alarms and fault messages. Once a fault is detected, the corresponding protective functions will be activated. The following faults are displayed as shown on the AC motor drive digital keypad display. The three most recent faults can be read from the digital keypad or communication. NOTE Wait 5 seconds after a fault has been cleared before performing reset via keypad of input terminal. 6.1 Common Problems and Solutions Fault Fault Descriptions Corrective Actions Name 1. Check if motor power corresponds with the AC motor drive output power. 2. Check the wiring connections to U/T1, V/T2, W/T3 for possible short circuits. 3. Check the wiring connections between the AC motor drive and motor for possible short circuits, also to ground. 4. Check for loose contacts between AC motor Over current drive and motor. Abnormal increase in current. 5. Increase the Acceleration Time. 6. Check for possible excessive loading conditions at the motor. 7. If there are still any abnormal conditions when operating the AC motor drive after a short- circuit is removed and the other points above are checked, it should be sent back to manufacturer. 1. Check if the input voltage falls within the rated AC motor drive input voltage range. Over voltage 2. Check for possible voltage transients. The DC bus voltage has 3. DC-bus over-voltage may also be caused by exceeded its maximum motor regeneration. Either increase the allowable value. Decel. Time or add an optional brake resistor. 4. Check whether the required braking power is within the specified limits. Revision August 2006, SE08, SW V2.61 6-1 Chapter 6 Fault Code Information|VFD-S Series Fault Fault Descriptions Corrective Actions Name 1. Ensure that the ambient temperature falls within the specified temperature range. 2. Make sure that the ventilation holes are not obstructed. Overheating 3. Remove any foreign objects from the heatsinks Heat sink temperature too high and check for possible dirty heat sink fins. 4. Check the fan and clean it. 5. Provide enough spacing for adequate ventilation. (See chapter 2) Low voltage 1. Check whether the input voltage falls within the The AC motor drive detects AC motor drive rated input voltage range. that the DC bus voltage has 2. Check for abnormal load in motor. fallen below its minimum 3. Check for correct wiring of input power to R-S-T value. (for 3-phase models) without phase loss. Overload The AC motor drive detects 1. Check whether the motor is overloaded. excessive drive output current. 2. Reduce torque compensation setting in Pr.7-02 NOTE: The AC motor drive 3. Use the next higher power AC motor drive can withstand up to 150% of model. the rated current for a maximum of 60 seconds. 1. Check for possible motor overload. 2. Check electronic thermal overload setting. Overload 1 3. Use a higher power motor. Internal electronic overload trip 4. Reduce the current level so that the drive output current does not exceed the value set by the Motor Rated Current Pr.7-00. 1. Reduce the motor load. Overload 2 2. Adjust the over-torque detection setting to an Motor overload. appropriate setting (Pr.6-03 to Pr.6-05). GFF hardware error Return to the factory. CC (current clamp) OC hardware error 1. Short-circuit at motor output: Check for possible poor insulation at the output lines. 2. Torque boost too high: Decrease the torque compensation setting in Pr.7-02 Over-current during 3. Acceleration Time too short: Increase the acceleration Acceleration Time. 4. AC motor drive output power is too small: Replace the AC motor drive with the next higher power model. 1. Short-circuit at motor output: Check for possible poor insulation at the output line. 2. Deceleration Time too short: Increase the Over-current during Deceleration Time. deceleration 3. AC motor drive output power is too small: Replace the AC motor drive with the next higher power model. 6-2 Revision August 2006, SE08, SW V2.61 Chapter 6 Fault Code Information|VFD-S Series Fault Fault Descriptions Corrective Actions Name 1. Short-circuit at motor output: Check for possible poor insulation at the output line. 2. Sudden increase in motor loading: Check for Over-current during possible motor stall. constant speed operation 3. AC motor drive output power is too small: Replace the AC motor drive with the next higher power model. 1. When multi-function input terminals (MI1-MI6) are set to external fault, the AC motor drive External Fault stops output U, V and W. 2. Give RESET command after fault has been cleared. Internal EEPROM can not be Return to the factory. programmed. Internal EEPROM can not be Return to the factory. programmed. 1. Switch off power supply. Drive’s internal circuitry 2. Check whether the input voltage falls within the abnormal. rated AC drive input voltage. Switch on the AC drive. OH error OV error LV error Return to the factory. Current detection error DC BUS detection error Current detection error When (one of) the output terminal(s) is grounded, short circuit current is more than 50% of AC motor drive rated current, the AC motor drive power module may be damaged. NOTE: The short circuit protection is provided Ground fault for AC motor drive protection, not for protection of the user. 1. Check whether the IGBT power module is damaged. 2. Check for possible poor insulation at the output line. 1. When the external input terminal (B.B) is active, the AC motor drive output will be External Base Block. turned off. (Refer to Pr. 8-06) 2. Deactivate the external input terminal (B.B) to operate the AC motor drive again. 1. Check if the motor is suitable for operation by AC motor drive. Auto accel/decel failure 2. Check if the regenerative energy is too large. 3. Load may have changed suddenly. Revision August 2006, SE08, SW V2.61 6-3 Chapter 6 Fault Code Information|VFD-S Series Fault Fault Descriptions Corrective Actions Name 1. Check the RS485 connection between the AC motor drive and RS485 master for loose wires and wiring to correct pins. 2. Check if the communication protocol, address, Communication Error transmission speed, etc. are properly set. 3. Use the correct checksum calculation. 4. Please refer to group 9 in the chapter 5 for detail information. Software protection failure Return to the factory. Keypad will be locked. Turn the power ON after Password is locked. power OFF to re-enter the correct password. See Pr.0-07 and 0-08. 1. Check parameter setting (Pr.A-00) and AVI/ACI wiring Analog feedback error or 2. Check for possible fault between system ACI open circuit response time and the feedback signal detection time (Pr.A-08). Phase Loss Check input phase wiring for loose contacts. 1. Check PID feedback wiring. PID feedback error 2. Check if the parameter setting is properly set. 6.2 Reset There are three methods to reset the AC motor drive after solving the fault: STOP/RESET 1. Press key on keypad. 2. Set external terminal to “RESET” (set one of Pr.4-04~Pr.4-08 to 06) and then set to be ON. 3. Send “RESET” command by communication. NOTE Make sure that RUN command or signal is OFF before executing RESET to prevent damage or personal injury due to immediate operation. 6-4 Revision August 2006, SE08, SW V2.61 Chapter 7 Troubleshooting 7.1 Over Current (OC) ocA ocd OC Over-current Over-current Over current during acceleration during deceleration Yes Remove short circuit Check if there is any short circuits and or ground fault grounding between the U, V, W and motor No No No Reduce the load or Yes increase the power Check if load is too large of AC motor drive No No No Reduce torque No No Suitable torque compensation compensation Yes Yes Reduce torque compensation Check if Check if No No acceleration time deceleration time is too short by is too short by load inertia. load inertia. Yes Yes Maybe AC motor drive has malfunction or error due to noise. Please Has load changed No contact with DELTA. suddenly? Yes Yes Yes Can deceleration Can acceleration time be made longer? time be made longer? No No Reduce load or increase Increase accel/decel the power of AC motor time drive Reduce load or increase Check braking the power of AC motor method. Please drive contact DELTA Revision August 2006, SE08, SW V2.61 7-1 Chapter 7 Troubleshooting |VFD-S Series 7.2 Ground Fault Maybe AC motor drive has Is output circuit(cable or GFF No malfunction or misoperation motor) of AC motor drive due to noise. Please Ground fault grounded? contact DELTA. Yes Remove ground fault 7.3 Over Voltage (OV) Over voltage No Reduce voltage to Is voltage within be within spec. specification Yes Yes Has over-voltage occurred without load No Maybe AC motor drive has malfunction or misoperation due to When OV occurs, check if the No noise. Please contact voltage of DC BUS is greater with DELTA. than protection value Yes Yes Increase Dose OV occur when No Yes deceleration sudden acceleration time stops Yes No Increase Yes acceleration Increase setting time time No Need to consider using No braking unit or Reduce moment Reduce moment of load inertia DC braking of inertia No No Use braking unit or DC braking Yes Need to check control method. Please contact DELTA. 7-2 Revision August 2006, SE08, SW V2.61 Chapter 7 Troubleshooting |VFD-S Series 7.4 Low Voltage (Lv) Low voltage Yes Is input power correct? Or power cut, Restart after reset including momentary power loss No Check if there is any malfunction Yes Change defective component component i or disconnection n and check connection power supply circuit No Make necessary corrections, Check if voltage is No such as change power supply within specification system for requirement Yes Check if there is heavy load Using the different power Yes with high start current in the supply for this drive and same power system heavy load system No No Check if Lv occurs when Yes Suitable power breaker and magnetic transformer capacity contactor is ON No Yes Check if voltage between +1/+2 and - is greater than No Maybe AC motor drive has malfunction. 200VDC (for 230V models) Please contact DELTA. 400VDC (for 460V models) 517VDC (for 575V models) Yes Control circuit has malfunction or misoperation due to noise. Please contact DELTA. Revision August 2006, SE08, SW V2.61 7-3 Chapter 7 Troubleshooting |VFD-S Series 7.5 Over Heat (OH) AC motor drive overheats Heat sink overheats No Check if temperature of heat sink Temperature detection malfunctions. O is greater than 90 C Please contact DELTA. Yes Yes Is load too large Reduce load No No If cooling fan functions normally Change cooling fan Yes Yes Remove obstruction Check if cooling fan is jammed No Maybe AC motor drive has malfunction or Check if surrounding temperature No misoperation due to noise. Please contact is within specification DELTA. Yes Adjust surrounding temperature to specification 7.6 Overload OL OL1/ OL2 Check for correct settings at No Modify setting Pr. 06-06 and 06-07 Yes No Maybe AC motor drive has malfunction Is load too large or misoperation due to noise. Yes Reduce load or increase the power of AC motor drive 7-4 Revision August 2006, SE08, SW V2.61 Chapter 7 Troubleshooting |VFD-S Series 7.7 Keypad Display is Abnormal Abnormal display or no display Yes Cycle power to AC motor drive Fix connector and eliminate noise No No Check if all connectors are connect Display normal? correctly and no noise is present Yes Yes AC motor drive works normally AC motor drive has malfunction. Please contact DELTA. 7.8 Phase Loss (PHL) Phase loss No Check wiring at R, S and T terminals Correct wiring Yes No Tighten all screws Check if the screws of terminals are tightened Yes Yes Please check the wiring Check if the input voltage of R, S, T is unbalanced and power system for abnormal power No Maybe AC motor drive has malfunction or misoperation due to noise. Please contact DELTA. Revision August 2006, SE08, SW V2.61 7-5 Chapter 7 Troubleshooting |VFD-S Series 7.9 Motor cannot Run Check PU01 Check if non-fuse No No for normal breaker and magnetic Set them to ON Motor cannot run display contactor are ON Yes Yes Yes Reset after clearing Check if there is any Check if any faults fault and then RUN No fault code displayed Check if input occur, such as voltage is normal Lv, PHL or disconnection No Yes It can run when If jumper or DC No Input "RUN" No Use jumper no faults occur reactor is connected command or DC reactor between +1 and +2/B1 by keypad Yes Yes Press RUN key to check if it can run Maybe AC motor drive has malfunction or misoperation due to noise. Please contact DELTA. Press UP key to set frequency Check if the wiring No No Yes Check if input FWD Yes of terminal FWD Change switch or relay or REV command and between Press UP to REV-DCM is correct check if motor Yes can run No No No No Set frequency or not Correct connection Modify frequency Yes setting No if upper bound freq. Check if the parameter and setting freq. is setting and wiring of Change defective lower than the min. Yes analog signal and potentiometer and output freq. multi-step speed relay No are correct Motor has malfunction Check if there is any No Maybe AC motor drive has malfunction. output voltage from Please contact DELTA. terminals U, V and W No Yes If load is too large Yes Yes Check if motor No Connect correctly connection Check if the setting is co rrect Yes of torque compensation is correct Motor is locked due to large load, please reduce load. For example, if there is a brake, check if it is released. No Increase the setting of torque compensation 7-6 Revision August 2006, SE08, SW V2.61 Chapter 7 Troubleshooting |VFD-S Series 7.10 Motor Speed cannot be Changed Motor can run but cannot change speed Check if the setting of the Yes Modify the setting max. frequency is too low Yes No If the setting of Check to see if frequency is Pr.05-17toPr.05-31 Yes out of range (upper/lower) Modify the setting is too high Yes boundaries No No Press UP/DOWN key If finished with Yes Yes to see if speed has No executing Is it in PLC mode any change Yes Pr.05-15 No If there is any change Yes If the setting of of the signal that sets Yes Pr.05-00 to Pr.05-14 frequency (0-10V and are the same 4-20mA) No No Check if the wiring between M1~M6 to DCM is correct No Check if the wiring of No external terminal is correct Yes Correct Yes wiring Check if frequency for Change defective each step is different No potentiometer Yes Change frequencysetting No Check if acc el./decel. time is set correctly Yes Please set suitable accel./decel. time by load inertia Maybe AC motor drive has malfunction or misoperation due to noise. Please contact DELTA. Revision August 2006, SE08, SW V2.61 7-7 Chapter 7 Troubleshooting |VFD-S Series 7.11 Motor Stalls during Acceleration Yes Motor stalls during Check if acceleration Increase setting time acceleration time is too short No Yes Check if the inertia Yes of the motor and load Use special motor? is too high No No Thicken or shorten the Reduce load or Check for low voltage Yes wiring between the increase the capacity at input motor or AC motor drive of AC motor drive No Reduce load or Yes Check if the load torque increase the capacity is too high of AC motor drive No Maybe AC motor drive has Check if the torque Yes malfunction or misoperation compensation is suitable due to noise. Please contact DELTA No Increase torque compensation 7.12 The Motor does not Run as Expected Check Pr. 01-01 thru Pr. 01-06 Motor does not run No Adjust Pr.01-01 to Pr.01-06 and torque compensation as expected and lower torque compensation settings Yes Yes Run in low speed continuously Please use specific motor No Yes Reduce load or increase the Is load too large capacity of AC motor drive No Yes Check if output voltage of U, V, W Motor has malfunction is balanced No Maybe AC motor drive has malfunction or misoperation due to noise. Please contact DELTA. 7-8 Revision August 2006, SE08, SW V2.61 Chapter 7 Troubleshooting |VFD-S Series 7.13 Electromagnetic/Induction Noise Many sources of noise surround AC motor drives and penetrate it by radiation or conduction. It may cause malfunctioning of the control circuits and even damage the AC motor drive. Of course, there are solutions to increase the noise tolerance of an AC motor drive. But this has its limits. Therefore, solving it from the outside as follows will be the best. 1. Add surge suppressor on the relays and contacts to suppress switching surges. 2. Shorten the wiring length of the control circuit or serial communication and keep them separated from the power circuit wiring. 3. Comply with the wiring regulations by using shielded wires and isolation amplifiers for long wire length. 4. The grounding terminal should comply with the local regulations and be grounded independently, i.e. not to have common ground with electric welding machines and other power equipment. 5. Connect a noise filter at the mains input terminal of the AC motor drive to filter noise from the power circuit. VFD-S can have a built-in filter as option. In short, solutions for electromagnetic noise exist of “no product”(disconnect disturbing equipment), “no spread”(limit emission for disturbing equipment) and “no receive”(enhance immunity). 7.14 Environmental Condition Since the AC motor drive is an electronic device, you should comply with the environmental conditions as stated in the Chapter 2.1. The following step should also be. 1. To prevent vibration, the use of anti-vibration dampers is the last choice. Vibrations must be within the specification. Vibration causes mechanical stress and it should not occur frequently, continuously or repeatedly to prevent damaging to the AC motor drive. 2. Store the AC motor drive in a clean and dry location, free from corrosive fumes/dust to prevent corroded contacts. It also may cause short by low insulation in a humid location. The solution is to use both paint and dust-proof. For particular occasion, use the enclosure with whole-seal structure. 3. The ambient temperature should be within the specification. Too high or too low temperature will affect the lifetime and reliability. For semiconductor components, damage will occur once any specification is out of range. Therefore, it is necessary to periodically check air quality and the cooling fan and provide extra cooling of necessary. In addition, the microcomputer may not work in extremely low temperatures, making cabinet heating necessary. Revision August 2006, SE08, SW V2.61 7-9 Chapter 7 Troubleshooting |VFD-S Series 4. Store within a relative humidity range of 0% to 90% and non-condensing environment. Use an air conditioner and/or exsiccator. 7.15 Affecting Other Machines An AC motor drive may affect the operation of other machines due to many reasons. Some solutions are: High Harmonics at Power Side � High harmonics at power side during running can be improved by: 1. Separate the power system: use a transformer for AC motor drive. 2. Use a reactor or rectifier at the power input terminal of the AC motor drive or decrease high harmonic by multiple circuit. 3. If phase lead capacitors are used (never on the AC motor drive output!!), use serial reactors to prevent capacitors damage from high harmonics. serial reactor phase lead capacitor � Motor Temperature Rises When the motor is a standard induction motor with fan, the cooling will be bad at low speeds, causing the motor to overheat. Besides, high harmonics at the output increases copper and core losses. The following measures should be used depending on load and operation range. 1. Use a motor with independent ventilation (forced external cooling) or increase the motor rated power. 2. Use a special inverter duty motor. 3. Do NOT run in the low speed range. 7-10 Revision August 2006, SE08, SW V2.61 Chapter 8 Maintenance and Inspections Modern AC motor drives are based on solid-state electronics technology. Preventive maintenance is required to keep the AC motor drive in its optimal condition, and to ensure a long life. It is recommended to have a qualified technician perform a check-up of the AC motor drive regularly. Daily Inspection: Basic check-up items to detect if there were any abnormalities during operation are: 1. Whether the motors are operating as expected. 2. Whether the installation environment is abnormal. 3. Whether the cooling system is operating as expected. 4. Whether any irregular vibration or sound occurred during operation. 5. Whether the motors are overheating during operation. 6. Always check the input voltage of the AC drive with a Voltmeter. Periodic Inspection: Before the check-up, always turn off the AC input power and remove the cover. Wait at least 10 minutes after all display lamps have gone out, and then confirm that the capacitors have fully discharged by measuring the voltage between ~ . It should be less than 25VDC. DANGER! 1. Disconnect AC power before processing! 2. Only qualified personnel shall install, wire and maintain AC motor drives. Please take off any metal objects, such as watches and rings, before operation. And only insulated tools are allowed. 3. Never reassemble internal components or wiring. 4. Prevent electric shocks. Revision August 2006, SE08, SW V2.61 8-1 Chapter 8 Maintenance and Inspections|VFD-S Series Periodical Maintenance � Ambient environment Maintenance Period Check Items Methods and Criterion Half One Daily Year Year Check the ambient temperature, Visual inspection and measurement humidity, vibration and see if � with equipment with standard there is any dust, gas, oil or specification water drops Check for any dangerous Visual inspection � objects near drive and motor � Voltage Maintenance Period Check Items Methods and Criterion Half One Daily Year Year Check if the voltage of main Measure with multimeter with standard circuit and control circuit is � specification correct � Keypad Maintenance Period Check Items Methods and Criterion Half One Daily Year Year Is the display clear for reading? Visual inspection � � Any missing characters? Visual inspection � Mechanical parts Maintenance Period Check Items Methods and Criterion Half One Daily Year Year If there is any abnormal sound Visual and aural inspection � or vibration If there are any loose screws Tighten the screws � 8-2 Revision August 2006, SE08, SW V2.61 Chapter 8 Maintenance and Inspections|VFD-S Series Maintenance Period Check Items Methods and Criterion Half One Daily Year Year Check partsfor deformity or Visual inspection � damaged If there is any color change Visual inspection � caused by overheating Check for dust and dirt Visual inspection � � Main circuit Maintenance Period Check Items Methods and Criterion Half One Daily Year Year If there are any loose or missing Tighten or replace the screw � screws If machine or insulator is Visual inspection deformed, cracked, damaged or NOTE: Please ignore the color � with changed color change due change of copper plate to overheating or ageing Check for dust and dirt Visual inspection � � Terminals and wiring of main circuit Maintenance Period Check Items Methods and Criterion Half One Daily Year Year If the wiring shows change of color change or deformation due Visual inspection � to overheat If the insulation of wiring is � damaged or the color has Visual inspection changed If there is any damage Visual inspection � Revision August 2006, SE08, SW V2.61 8-3 Chapter 8 Maintenance and Inspections|VFD-S Series � DC capacity of main circuit Maintenance Period Check Items Methods and Criterion Half One Daily Year Year If there is any leakage of liquid, change of color, cracks or Visual inspection � deformation Measure static capacity when Static capacity initial value X 0.85 � ≥ required � Resistor of main circuit Maintenance Period Check Items Methods and Criterion Half One Daily Year Year If there is any peculiar smell or insulator cracks due to Visual inspection, smell � overheating Visual inspection or measure with multimeter after removing wiring If there is any disconnection � between +1/+2 ~ - ± Resistor value should be within 10% � Transformer and reactor of main circuit Maintenance Period Check Items Methods and Criterion Half One Daily Year Year If there is any abnormal vibration � Visual, aural inspection and smell or peculiar smell � Magnetic contactor and relay of main circuit Maintenance Period Check Items Methods and Criterion Half One Daily Year Year Visual and aural inspection. Tighten If there are any loose screws � screw if necessary. Check to see if contacts work Visual inspection � correctly 8-4 Revision August 2006, SE08, SW V2.61 Chapter 8 Maintenance and Inspections|VFD-S Series � Printed circuit board and connector of main circuit Maintenance Period Check Items Methods and Criterion Half One Daily Year Year If there are any loose screws and Tighten the screws and press the � connectors connectors firmly in place. If there is any peculiar smell and Visual inspection and smell � color change If there is any crack, damage, Visual inspection � deformation or corrosion If there is any leaked liquid or Visual inspection � deformation in capacitors � Cooling fan of cooling system Maintenance Period Check Items Methods and Criterion Half One Daily Year Year Visual, aural inspection and turn the If there is any abnormal sound or fan with hand (turn off the power � vibration before operation) to see if it rotates smoothly If there is any loose screw Tighten the screw � If there is any change of color due Change fan � to overheating � Ventilation channel of cooling system Maintenance Period Check Items Methods and Criterion Half One Daily Year Year If there is any obstruction in the Visual inspection � heat sink, air intake or air outlet Revision August 2006, SE08, SW V2.61 8-5 Chapter 8 Maintenance and Inspections|VFD-S Series This page intentionally left blank 8-6 Revision August 2006, SE08, SW V2.61 Appendix A Specifications Voltage Class 115V Class 230V Class 460V Class Model Number VFD-XXXS 002 004 007 002 004 007 015 022 004 007 015 022 Max. Applicable Motor Output (kW) 0.2 0.4 0.75 0.2 0.4 0.75 1.5 2.2 0.4 0.75 1.5 2.2 Max. Applicable Motor Output (HP) 0.25 0.5 1.0 0.25 0.5 1.0 2.0 3.0 0.5 1.0 2.0 3.0 Rated Output Capacity (KVA) 0.6 1.0 1.6 0.6 1.0 1.6 2.9 4.2 1.2 2.0 3.3 4.4 Rated Output Current (A) 1.6 2.5 4.2 1.6 2.5 4.2 7.5 11.0 1.5 2.5 4.2 5.5 3-phase Proportional to Maximum Output Voltage (V) 3-phase Proportional to Input Voltage Twice the Input Voltage Rated Frequency (Hz) 1.0 to 400 Hz Single phase Single/3-phase model drive 3-phase Rated Input Current (A) 4.9/ 6.5/ 9.7/ 15.7/ 24/ 6 9 18 1.7 2.9 5.1 6.9 1.9 2.7 5.1 9.0 15 Input Current for 1-phase model drive to be used as 3-phase -- -- 1.6 3.0 5.1 8.4 -- -- -- model drive 100/110/120 VAC 200/208/220/240 VAC 380/400/415/480 VAC Rated Voltage/Frequency 50/60 Hz 50/60Hz 50/60Hz Voltage/Freq. Tolerance Voltage: ±10%, Frequency: ±5% Control System SPWM (Sinusoidal Pulse Width Modulation, carrier frequency 3k-10kHz) Output Frequency Resolution 0.1Hz Including the auto-torque, auto-slip compensation; starting torque can be Torque Characteristics 150% at 5Hz Overload Endurance 150% of rated current for 1 minute Accel/Decel Time 0.1to 600 second (2 Independent settings for Accel/Decel Time) V/F Pattern V/F pattern adjustable Stall Prevention Level 20 to 250%, Setting of Rated Current Keypad Setting by or Potentiometer Frequency Potentiometer-5KΩ/0.5W, DC 0 to +10V or 0 to +5V (Input impedance Setting External 47KΩ), RS-485 interface, 4 to 20mA (Input impedance 250Ω); Multi- Signal Function Inputs 1 to 5 (7 steps, Jog, up/down) Keypad Setting by RUN, STOP Operation External M0 to M5 can be combined to offer various modes of operation, RS-485 Setting Signal Signal serial interface (MODBUS). Multi-step selection 0 to7, Jog, accel/decel inhibit, first/second accel/decel Multi-Function Input Signal switch, counter, 8-step PLC operation, external Base Block (NC, NO), increase/decrease Master Frequency AC Drive Operating, Frequency Attained, Non-zero, Base Block, Fault Multi-Function Output Indication Indication, Local/Remote indication, PLC Operation indication. Analog Output Signal Analog frequency/current signal output. AVR, S-Curve, Over-Voltage/Over-Current Stall Prevention, Fault Records, Adjustable Carrier Frequency, DC Braking, Start Frequency for DC Braking, Other Function Momentary Power Loss restart, Frequency Limits, Parameter Lock/Reset, PID Feedback Control, Reverse Inhibition, etc. VFD002S21E, VFD004S21E, VFD004S43E, VFD007S21E, VFD007S43E, Built-in EMI Filter VFD015S21E, VFD015S43E, VFD022S21E, VFD022S43E Self-testing, Over Voltage, Over Current, Under Voltage, Overload, Protection Overheating, External Fault, Electronic thermal, Ground Fault. Forced air-cooling (ONLY FOR 022S2XA/B; XXXS43A/B/E 1HP~3HP; Cooling XXXSXXD; XXXS21E 400W~3HP). Others are Natural air-cooling. Revision August 2006, SE08, SW V2.61 Control Operating Characteristics Input Rating Output Rating Characteristics Appendix A Specifications|VFD-S Series Installation Location Altitude 1,000 m or below, keep from corrosive gasses, liquid and dust Pollution Degree 2 ° ° Ambient Temperature -10 C to 40 C (Non-Condensing and not frozen) ° ° Storage Temperature -20 C to 60 C Ambient Humidity Below 90% RH (non-condensing) 2 2 Vibration 9.80665m/s (1G) less than 20Hz, 5.88m/s (0.6G) at 20 to 50Hz A-2 Revision August 2006, SE08, SW V2.61 Enviroment Appendix B Accessories B.1 All Brake Resistors & Brake Units Used in AC Motor Drives Note: Please only use DELTA resistors and recommended values. Other resistors and values will void Delta’s warranty. Please contact your nearest Delta representative for use of special resistors. The brake unit should be at least 10 cm away from AC motor drive to avoid possible interference. Refer to the “Brake unit Module User Manual” for further details. Applicable Resistor Full Load Brake Resistors Braking Min. Equivalent Motor value spec Torque Torque Model and No. Resistor Value for for each AC of Units Used 10%ED each AC Motor Drive hp kW Nm Motor Drive 1/4 0.2 0.110 80W 200Ω BR080W200 1 400 120Ω 80W 200Ω 120Ω 1/2 0.4 0.216 BR080W200 1 220 1 0.75 0.427 80W 200Ω BR080W200 1 125 80Ω 300W 100Ω 55Ω 2 1.5 0.849 BR300W100 1 125 3 2.2 1.262 300W 70Ω BR300W70 1 125 35Ω 1/2 0.4 0.216 80W 750Ω BR080W750 1 230 470Ω 80W 750Ω 260Ω 1 0.75 0.427 BR080W750 1 125 2 1.5 0.849 300W 400Ω BR300W400 1 125 190Ω 3 2.2 1.262 300W 250Ω BR300W250 1 125 145Ω NOTE 1. Please select the brake unit and/or brake resistor according to the table. 2. If damage to the drive or other equipment is due to the fact that the brake resistors and the braking modules in use are not provided by Delta, the warranty will be void. 3. Take into consideration the safety of the environment when installing the brake resistors. 4. If the minimum resistance value is to be utilized, consult local dealers for the calculation of the power in Watt. 5. Please select thermal relay trip contact to prevent resistor over load. Use the contact to switch power off to the AC motor drive! 6. When using more than 2 brake units, equivalent resistor value of parallel brake unit can’t be less than the value in the column “Minimum Equivalent Resistor Value for Each AC Drive” (the right-most column in the table). 7. Please read the wiring information in the user manual of the brake unit thoroughly prior to Revision August 2006, SE08, SW V2.61 460V 115V/230V Voltage Series Series Appendix B Accessories|VFD-S Series installation and operation. B.1.1 Dimensions and Weights for Brake resistors (Dimensions are in millimeter) Order P/N: BR080W200, BR080W750, BR300W70, BR300W100, BR300W250, BR300W400, BR400W150, BR400W040 Model no. L1 L2 H D W Max. Weight (g) BR080W200 140 125 20 5.3 60 160 BR080W750 BR300W70 BR300W100 215 200 30 5.3 60 750 BR300W250 BR300W400 BR400W150 265 250 30 5.3 60 930 BR400W040 B-2 Revision August 2006, SE08, SW V2.61 Appendix B Accessories|VFD-S Series B.2 EMI Filters The DELTA VFD-S Series 0.25-3HP, 115V, 230V, 460V AC drive uses DELTA EMI Filter. Use the table below to find the appropriate filter for your DELTA VFD-S drive. Model of AC Motor Drive EMI Filter VFD002S21A/B, VFD004S21A/B, VFD007S21A/B RF007S21AA VFD015S21D/U, VFD022S21D/U RF022S21BA VFD004S43A/B, VFD007S43A/B RF007S43AA VFD002S11A/B, VFD004S11A/B 12DKT1W3S VFD002S23A, VFD004S23A, VFD007S23A 08TDT1W4S VFD007S11A/B 22DRT1W3S Installation All electrical equipment, including AC motor drives, will generate high-frequency/low-frequency noise and will interfere with peripheral equipment by radiation or conduction when in operation. By using an EMI filter with correct installation, much interference can be eliminated. It is recommended to use DELTA EMI filter to have the best interference elimination performance. We assure that it can comply with following rules when AC motor drive and EMI filter are installed and wired according to user manual: � EN61000-6-4 � EN61800-3: 1996 + A11: 2000 st � EN55011 (1991) Class A Group 1 (1 Environment, restricted distribution) General precaution 1. EMI filter and AC motor drive should be installed on the same metal plate. 2. Please install AC motor drive on footprint EMI filter or install EMI filter as close as possible to the AC motor drive. 3. Please wire as short as possible. 4. Metal plate should be grounded. 5. The cover of EMI filter and AC motor drive or grounding should be fixed on the metal plate and the contact area should be as large as possible. Choose suitable motor cable and precautions Improper installation and choice of motor cable will affect the performance of EMI filter. Be sure to observe the following precautions when selecting motor cable. Revision August 2006, SE08, SW V2.61 B-3 Appendix B Accessories|VFD-S Series 1. Use the cable with shielding (double shielding is the best). 2. The shielding on both ends of the motor cable should be grounded with the minimum length and maximum contact area. 3. Remove any paint on metal saddle for good ground contact with the plate and shielding. Remove any paint on metal saddle for good ground contact with the plate and shielding. saddle the plate with grounding Saddle on both ends Saddle on one end B-4 Revision August 2006, SE08, SW V2.61 Appendix B Accessories|VFD-S Series The length of motor cable When motor is driven by an AC motor drive of PWM type, the motor terminals will experience surge voltages easily due to components conversion of AC motor drive and cable capacitance. When the motor cable is very long (especially for the 460V series), surge voltages may reduce insulation quality. To prevent this situation, please follow the rules below: � Use a motor with enhanced insulation. � Connect an output reactor (optional) to the output terminals of the AC motor drive � The length of the cable between AC motor drive and motor should be as short as possible (10 to 20 m or less) � For models 7.5hp/5.5kW and above: Insulation level of motor 1000V 1300V 1600V 460VAC input voltage 66 ft (20m) 328 ft (100m) 1312 ft (400m) 230VAC input voltage 1312 ft (400m) 1312 ft (400m) 1312 ft (400m) � For models 5hp/3.7kW and less: Insulation level of motor 1000V 1300V 1600V 460VAC input voltage 66 ft (20m) 165 ft (50m) 165 ft (50m) 230VAC input voltage 328 ft (100m) 328 ft (100m) 328 ft (100m) NOTE When a thermal O/L relay protected by motor is used between AC motor drive and motor, it may malfunction (especially for 460V series), even if the length of motor cable is only 165 ft (50m) or less. To prevent it, please use AC reactor and/or lower the carrier frequency (Pr. 02-03 PWM carrier frequency). NOTE Never connect phase lead capacitors or surge absorbers to the output terminals of the AC motor drive. Revision August 2006, SE08, SW V2.61 B-5 Appendix B Accessories|VFD-S Series � If the length is too long, the stray capacitance between cables will increase and may cause leakage current. It will activate the protection of over current, increase leakage current or not insure the correction of current display. The worst case is that AC motor drive may damage. � If more than one motor is connected to the AC motor drive, the total wiring length is the sum of the wiring length from AC motor drive to each motor. B.2.1 Dimensions Dimensions are in millimeter and (inch) Order P/N: RF007S21AA/ RF007S43AA 50 85 (1.97) (3.35) 27 60 (1.06) (2.36) 200 200 213 (8.39) (7.87) (7.87) 15 24 4.5 (0.52) (0.94) (0.18) B-6 Revision August 2006, SE08, SW V2.61 Appendix B Accessories|VFD-S Series Order P/N: RF022S21BA 50 100 (1.97) (3.94) 27 74 (1.06) (2.91) 228 228 241 (8.98) (8.98)(9.49) 15 24 5.5 (0.59) (0.94) (0.22) Revision August 2006, SE08, SW V2.61 B-7 Appendix B Accessories|VFD-S Series Order P/N: 12DKT1W3S Order P/N: 08TDT1W4S B-8 Revision August 2006, SE08, SW V2.61 POWER-IN Appendix B Accessories|VFD-S Series Order P/N: 22DRT1W3S Order P/N: 35DRT1W3C Revision August 2006, SE08, SW V2.61 B-9 POWER-IN POWER-IN Appendix B Accessories|VFD-S Series B.3 AC Reactor B.3.1 AC Input Reactor Recommended Value 230V, 50/60Hz, 1-Phase Inductance (mH) Fundamental Max. continuous kW HP Amps Amps 3~5% impedance 0.2 1/4 4 6 6.5 0.4 1/2 5 7.5 3 0.75 1 8 12 1.5 1.5 2 12 18 1.25 2.2 3 18 27 0.8 B-10 Revision August 2006, SE08, SW V2.61 Appendix B Accessories|VFD-S Series 460V, 50/60Hz, 3-Phase Max. Inductance (mH) Fundamental kW HP continuous Amps 3% impedance 5% impedance Amps 0.4 1/2 2 3 20 32 0.75 1 4 6 9 12 1.5 2 4 6 6.5 9 2.2 3 8 12 5 7.5 B.3.2 AC Output Reactor Recommended Value 115V/230V, 50/60Hz, 3-Phase Max. Inductance (mH) Fundamental kW HP continuous Amps 3% impedance 5% impedance Amps 0.2 1/4 4 4 9 12 0.4 1/2 6 6 6.5 9 0.75 1 8 12 3 5 1.5 2 8 12 1.5 3 2.2 3 12 18 1.25 2.5 460V, 50/60Hz, 3-Phase Max. Inductance (mH) Fundamental kW HP continuous Amps 3% impedance 5% impedance Amps 0.4 1/2 2 3 20 32 0.75 1 4 6 9 12 1.5 2 4 6 6.5 9 2.2 3 8 12 5 7.5 B.3.3 Applications for AC Reactor Connected in input circuit Application 1 Question When more than one AC motor drive is When applying power to one of the AC motor connected to the same mains power, and one drive, the charge current of the capacitors of them is ON during operation. may cause voltage dip. The AC motor drive Revision August 2006, SE08, SW V2.61 B-11 Appendix B Accessories|VFD-S Series may be damaged when over current occurs during operation. B-12 Revision August 2006, SE08, SW V2.61 Appendix B Accessories|VFD-S Series Correct wiring reactor M1 motor AC motor drive M2 motor AC motor drive Mn motor AC motor drive Application 2 Question Silicon rectifier and AC motor drive are Switching spikes will be generated when the connected to the same power. silicon rectifier switches on/off. These spikes may damage the mains circuit. Correct wiring silicon rectifier power reactor DC AC motor drive reactor motor Revision August 2006, SE08, SW V2.61 B-13 Appendix B Accessories|VFD-S Series Application 3 Question Used to improve the input power factor, to When the mains power capacity is too large, reduce harmonics and provide protection from line impedance will be small and the charge AC line disturbances. (surges, switching current will be too high. This may damage AC spikes, short interruptions, etc.). The AC line motor drive due to higher rectifier reactor should be installed when the power temperature. supply capacity is 500kVA or more and exceeds 6 times the inverter capacity, or the mains wiring distance 10m. ≤ Correct wiring small-capacity large-capacity AC motor drive power reactor motor B-14 Revision August 2006, SE08, SW V2.61 Appendix B Accessories|VFD-S Series B.4 DC Choke Recommended Values 230V DC Choke Input voltage kW HP DC Amps Inductance (mh) MTE CAT. NO 2 20.00 2RB003 0.2 1/4 4 15.00 4RB003 230Vac 0.4 1/2 50/60Hz 0.75 1 9 7.50 9RB003 3-Phase 1.5 2 12 4.00 12RB003 2.2 3 18 2.75 18RB003 0.2 1/4 4 50.00 -- 230Vac 0.4 1/2 9 25.00 -- 50/60Hz 0.75 1 9 12.00 -- 1-Phase 1.5 2 12 8.00 -- 2.2 3 18 6.00 -- 460V DC Choke Input voltage kW HP DC Amps Inductance (mh) MTE CAT. NO 0.4 1/2 2 50.00 2RB004 460Vac 0.75 1 4 25.00 4RB004 50/60Hz 1.5 2 9 11.50 9RB004 3-Phase 2.2 3 9 11.50 9RB004 Revision August 2006, SE08, SW V2.61 B-15 Appendix B Accessories|VFD-S Series B.5 Zero Phase Reactor (RF220X00A) Dimensions are in millimeter and (inch) Motor Recommended Wire Size Qty. 2 (mm ) HP kW 1/4 0.2 1/2 0.4 0.5 - 5.5 1 0.75 1 2 1.5 3 2.2 3.5 - 5.5 1/4 0.2 1/2 0.4 1 0.75 1 0.5 - 5.5 2 1.5 3 2.2 Wiring Method Please wind each wire 4 times around the core. The reactor must be put at inverter output as close as possible. Zero Phase Reactor R/L1 U/T1 Power S/L2 V/T2 MOTOR Supply T/L3 W/T3 B-16 Revision August 2006, SE08, SW V2.61 460V 115V/230VSeri Series es Appendix B Accessories|VFD-S Series B.6 Din Rail-DR01 (Dimensions are in millimeter) Models Screw Size VFD002S11A/B M4*22 VFD002S21A/B/E M4*22 VFD002S23A/B M4*22 � To install the Din Rail Adapter use the specified screws for different models. Refer to the above VFD004S11A/B M4*12 chart. VFD004S21A/B/E M4*12 � To mount the drive on a Din Rail, place the drive VFD004S23A/B M4*12 on the rail and push the lever toward the rail. VFD004S43A/B/E M4*12 VFD007S21A/B/E M4*12 VFD007S23A/B M4*12 VFD007S43A/B/E M4*12 VFD015S23D M4*12 Revision August 2006, SE08, SW V2.61 B-17 Appendix B Accessories|VFD-S Series B.7 Remote Controller RC-01 (Dimensions are in millimeter) RC-01 86 5 416 15 14 13 11 Terminal block (Wiring connections) VFD-S AFM GND AVI +10V GNDM2 M0 M1 M3 I/O Block VFD-S Programming Pr. 2-00 and Pr. 2-01 set to d01 Pr. 4-04 set to d02 (M0, M1 set at RUN/STOP and FWD/REV) Pr. 4-05 set to d06 (M2 set for reset) Pr. 4-06 set to d10 (M3 set for jog operation) B-18 Revision August 2006, SE08, SW V2.61 28.0(1.1) 22.0(0.87) 22.0(0.87) Appendix B Accessories|VFD-S Series B.8 Conduit Bracket (BK-S) (Dimensions are in millimeter) 73.0(2.87) Revision August 2006, SE08, SW V2.61 B-19 67.8(2.67) 25.2(1.0) 29.7(1.17) 15.5(0.61) Appendix B Accessories|VFD-S Series B.9 Non-fuse Circuit Breaker Chart Per UL 508C, paragraph 45.8.4, part a: 1. For 1-phase drives, the current rating of the breaker shall be 4 times maximum input current rating. 2. For 3-phase drives, the current rating of the breaker shall be 4 times maximum output current rating. (Refer to Appendix A for rated input/output current) 1-phase 3-phase Recommended Recommended Model Model non-fuse breaker (A) non-fuse breaker (A) 5 15 VFD002S11A/B VFD002S23A 5 10 VFD002S21A/B/E VFD004S23A 5 20 VFD004S11A/B VFD004S43A/B/E 10 15 VFD004S21A/B/E VFD007S23A 5 30 VFD007S11A/B VFD007S43A/B/E 20 20 VFD007S21A/B/E VFD015S23D 10 30 VFD015S21D/E VFD015S43D/E/U 30 50 VFD022S21D/E/U VFD022S23D 15 VFD022S43D/E/U Fuse Specification Chart Smaller fuses than those shown in the table are permitted. Line Fuse Model I (input)(A) I (output)(A) I (A) Bussmann P/N VFD002S11A/B 6 1.6 15 JJN-15 VFD002S21A/B/E 4,9 1.6 10 JJN-10 VFD002S23A 2.4 1.6 5 JJN-6 VFD004S11A/B 9 2.5 20 JJN-20 VFD004S21A/B/E 6.5 2.5 15 JJN-15 VFD004S23A 3.0 2.5 5 JJN-6 VFD004S43A/B/E 1.9 1.5 5 JJN-5 VFD007S11A/B 18 4.2 30 JJN-30 VFD007S21A/B/E 9.7 4.2 20 JJN-20 VFD007S23A 5.1 4.2 10 JJN-10 VFD007S43A/B/E 3.2 2.5 5 JJN-5 VFD015S21D/E 15.7 7.5 30 JJN-30 VFD015S23D 9.0 7.5 20 JJN-20 VFD015S43D/E/U 4.3 4.2 10 JJN-10 VFD022S21D/E/U 24 11.0 50 JJN-50 VFD022S23D 15 11.0 30 JJN-30 VFD022S43D/E/U 7.1 5.5 15 JJN-15 B-20 Revision August 2006, SE08, SW V2.61 Appendix C How to Select the Right AC Motor Drive The choice of the right AC motor drive for the application is very important and has great influence on its lifetime and the performance. If the capacity of AC motor drive is too large, it cannot offer complete protection to the motor and it may be damaged. If the capacity of AC motor drive is too small, it cannot offer the required performance and the AC motor drive may be damaged due to overloading. But by simply selecting the AC motor drive of the same capacity as the motor, user application requirements cannot always be fully met. Therefore, a designer should consider all the conditions, including load type, load speed, load characteristic, operation method, rated output, rated speed, power and the change of load capacity. The following table lists the factors you need to consider, depending on your requirements. Related Specification Speed and Item Time Overload Starting torque ratings capacity torque characteristics Friction load and weight load Liquid (viscous) load ● ● Load type Inertia load Load with power transmission Constant torque Load speed Constant output and torque ● ● Decreasing torque characteristics Decreasing output Constant load Shock load Load Repetitive load ● ● ● ● characteristics High starting torque Low starting torque Continuous operation, Short-time operation ● ● Long-time operation at medium/low speeds Maximum output current (instantaneous) ● ● Constant output current (continuous) Maximum frequency, Base frequency ● Power supply transformer capacity or percentage impedance ● ● Voltage fluctuations and unbalance Number of phases, single phase protection Frequency Mechanical friction, losses in wiring ● ● ● Duty cycle modification Revision August 2006, SE08, SW V2.61 Appendix D CE|VFD-S Series C.1 Capacity Formulas 1. When one AC motor drive operates one motor The starting capacity should be less than 1.5x rated capacity of AC motor drive The starting capacity is 2 k× N ⎛ GD N⎞ ⎜T + × ⎟≤ 1.5× the _ capacity _ of _ AC _ motor _ drive(kVA) L ⎜ ⎟ 973×η× cosϕ 375 t ⎝ A⎠ 2. When one AC motor drive operates more than one motor 2.1 The starting capacity should be less than the rated capacity of the AC motor drive � Acceleration time ≦60 seconds The starting capacity is ⎡ ⎤ k× N ns ⎢ ⎥ [] nT+ ns() ks− 1 = PC1 1+ () ks− 1 ≤ 1.5× the _ capacity _ of _ AC _ motor _ drive(kVA) ⎢ ⎥ η× cosϕ ⎢ nT ⎥ ⎣ ⎦ � Acceleration time ≧60 seconds The starting capacity is ⎡ ⎤ k× N ns ⎢ ⎥ [] nT+ ns() ks− 1 = PC1 1+() ks− 1 ≤ the _ capacity _ of _ AC _ motor _ drive(kVA) ⎢ ⎥ η× cosϕ ⎢ nT ⎥ ⎣ ⎦ 2.2 The current should be less than the rated current of the AC motor drive(A) � Acceleration time ≦60 seconds ⎡ ⎤ nS ⎛ ⎞ nT+ IM⎢1+ ⎜kS−1⎟⎥≤ 1.5× the _ rated _ current _ of _ AC _ motor _ drive(A) ⎝ ⎠ ⎣ nT ⎦ � Acceleration time ≧60 seconds ⎡ ⎤ nS ⎛ ⎞ nT+ IM⎢1+ ⎜kS−1⎟⎥≤ the _ rated _ current _ of _ AC _ motor _ drive(A) ⎣ nT⎝ ⎠⎦ C-2 Revision August 2006, SE08, SW V2.61 Error! Reference source not found. Error! Reference source not found.|VFD-S Series 2.3 When it is running continuously � The requirement of load capacity should be less than the capacity of the AC motor drive(kVA) The requirement of load capacity is k× PM ≤ the _ capacity_ of _ AC _ motor _ drive(kVA) η× cosϕ � The motor capacity should be less than the capacity of AC motor drive −3 k× 3×VM× IM×10 ≤ the_capacity_ of _ AC _ motor_ drive(kVA) � The current should be less than the rated current of AC motor drive(A) k× IM ≤ the _ rated _ current _ of _ AC _ motor _ drive(A) Symbol explanation PM : Motor shaft output for load (kW) η : Motor efficiency (normally, approx. 0.85) cosϕ : Motor power factor (normally, approx. 0.75) : Motor rated voltage (V) VM : Motor rated current (A), for commercial power IM : Correction factor calculated from current distortion factor (1.05-1.1, depending on k PWM method) : Continuous motor capacity (kVA) PC1 : Starting current/rated current of motor kS nT : Number of motors in parallel nS : Number of simultaneously started motors 2 2 2 : Total inertia (GD ) calculated back to motor shaft (kg m ) GD : Load torque TL tA : Motor acceleration time : Motor speed N Revision August 2006, SE08, SW V2.61 C-3 Appendix D CE|VFD-S Series C.2 General Precautions Selection Note A. When the AC Motor Drive is connected directly to a large-capacity power transformer (600kVA or above) or when phase lead capacitors are switched, excess peak currents may occur in the power input circuit and the rectifier section might be damaged. To avoid this, use an AC input reactor (optional) before AC Motor Drive mains input to reduce the current and improve the input power efficiency. B. When a special motor is used or more than one motor is driven in parallel with a single AC Motor Drive, select the AC Motor Drive current ≥1.25x(Sum of the motor rated currents). C. The starting and accel./decel. characteristics of a motor are limited by the rated current and the overload protection of the AC Motor Drive. Compared to running the motor D.O.L. (Direct On-Line), a lower starting torque output with AC Motor Drive can be expected. If higher starting torque is required (such as for elevators, mixers, tooling machines, etc.) use an AC Motor Drive of higher capacity or increase the capacities for both the motor and the AC Motor Drive. D. When an error occurs on the drive, a protective circuit will be activated and the AC Motor Drive output is turned off and the motor will coast to stop. For an emergency stop, an external mechanical brake is needed to quickly stop the motor. Parameter Settings Note A. The AC Motor Drive can be driven at an output frequency up to 400Hz (less for some models). Setting errors may create a dangerous situation. For safety, the use of the upper limit frequency function is strongly recommended. B. High DC braking operating voltages and long operation time (at low frequencies) may cause overheating of the motor. In that case, forced external motor cooling is recommended. C. Motor accel./decel. time is determined by motor rated torque, load torque, and load inertia. C-4 Revision August 2006, SE08, SW V2.61 Error! Reference source not found. Error! Reference source not found.|VFD-S Series D. If the stall prevention function is activated, the accel./decel. time is automatically extended to a length that the AC Motor Drive can handle. If the motor needs to decelerate within a certain time with high load inertia that can’t be handled by the AC Motor Drive in the required time, either use an external brake resistor and/or brake unit, depending on the model, (to shorten deceleration time only) or increase the capacity for both the motor and the AC Motor Drive. C.3 How to Choose a Suitable Motor Standard motor When using the AC Motor Drive to control a standard 3-phase induction motor, take the following precautions: A. The motor losses are greater than for an inverter duty motor. B. Avoid running the motor at low speed for a long time. Under this condition, the motor temperature may rise above the motor rating due to limited airflow produced by the motor’s fan. Consider external forced motor cooling. C. When the standard motor operates at low speed for long time, the output load must be decreased. D. The load tolerance of a standard motor is as follows: Load duty-cycle 25% 40% 60% 100 82 70 60 continuous 50 0 3 6 20 60 Frequency (Hz) Revision August 2006, SE08, SW V2.61 C-5 torque(%) Appendix D CE|VFD-S Series E. If 100% continuous torque is required at low speed, it may be necessary to use a special inverter duty motor. F. Motor dynamic balance and rotor endurance should be considered if the operating speed exceeds the rated speed (60Hz) of a standard motor. G. Motor torque characteristics vary when an AC Motor Drive instead of commercial power supply drives the motor. Check the load torque characteristics of the machine to be connected. H. Because of the high carrier frequency PWM control of the VFD series, pay attention to the following motor vibration problems: � Resonant mechanical vibration: anti-vibration (damping) rubbers should be used to mount equipment that runs at varying speed. � Motor imbalance: special care is required for operation at 50 or 60 Hz and higher frequency. � To avoid resonances, use the Skip frequencies. I. The motor fan will be very noisy when the motor speed exceeds 50 or 60Hz. Special motors: A. Pole-changing (Dahlander) motor: The rated current is different from that of a standard motor. Please check before operation and select the capacity of the AC motor drive carefully. When changing the pole number the motor needs to be stopped first. If over current occurs during operation or regenerative voltage is too high, please let the motor free run to stop (coast). B. Submersible motor: The rated current is higher than that of a standard motor. Please check before operation and choose the capacity of the AC motor drive carefully. With long motor cable between AC motor drive and motor, available motor torque is reduced. C. Explosion-proof (Ex) motor: Needs to be installed in a safe place and the wiring should comply with the (Ex) requirements. Delta AC Motor Drives are not suitable for (Ex) areas with special precautions. C-6 Revision August 2006, SE08, SW V2.61 Error! Reference source not found. Error! Reference source not found.|VFD-S Series D. Gear reduction motor: The lubricating method of reduction gearbox and speed range for continuous operation will be different and depending on brand. The lubricating function for operating long time at low speed and for high-speed operation needs to be considered carefully. E. Synchronous motor: The rated current and starting current are higher than for standard motors. Please check before operation and choose the capacity of the AC motor drive carefully. When the AC motor drive operates more than one motor, please pay attention to starting and changing the motor. Power Transmission Mechanism Pay attention to reduced lubrication when operating gear reduction motors, gearboxes, belts and chains, etc. over longer periods at low speeds. At high speeds of 50/60Hz and above, lifetime reducing noises and vibrations may occur. Motor torque The torque characteristics of a motor operated by an AC motor drive and commercial mains power are different. Below you’ll find the torque-speed characteristics of a standard motor (4-pole, 15kW): Revision August 2006, SE08, SW V2.61 C-7 Appendix D CE|VFD-S Series AC motor drive Motor 180 180 60 seconds 60 60 se sec co on nd ds s 155 155 140 100 100 80 55 55 38 38 0 0 320 60 320 60 120 120 Frequency (Hz) Frequency (Hz) Base freq.: 60Hz Base freq.: 60Hz V/F for 220V/60Hz V/F for 220V/60Hz 180 60 seconds 60 seconds 140 150 130 100 100 85 68 80 45 45 35 35 0 0 320 50 20 50 120 3 120 Frequency (Hz) Frequency (Hz) Base freq.: 50Hz Base freq.: 50Hz V/F for 220V/50Hz V/F for 220V/50Hz C-8 Revision August 2006, SE08, SW V2.61 torque (%) torque (%) torque (%) torque (%) Appendix D CE DELTA ELECTRONICS, INC. EC Declaration of Conformity According to the Low Voltage Directive 73/23/EEC and the Amendment Directive 93/68/EEC For the following equipment: AC Motor Drive (Product Name) VFD002S11A/B, VFD004S11A/B, VFD007S11A/B, VFD022S21A/B, VFD002S23B, VFD004S23B, VFD007S23A/B, VFD022S23A/B/D, VFD004S43A/B/E, VFD007S43A/B/E, VFD015S43A/B/D/E/U, VFD022S43A/B/D/E/U, VFD015S21A/B/D/E/U, VFD022S21A/B/D/E/U, VFD007S21A/B/E, VFD004S21A/B/E, VFD015S23A/B/D (Model Name) is herewith confirmed to comply with the requirements set out in the Council Directive 73/23/EEC for electrical equipment used within certain voltage limits and the Amendment Directive 93/68/EEC. For the evaluation of the compliance with this Directive, the following standard was applied: EN 50178 The following manufacturer/importer is responsible for this declaration: Delta Electronics, Inc. (Company Name) 31-1, Shien Pan Road, Kuei San Industrial Zone, Taoyuan Shien, Taiwan 333 (Company Address) Revision August 2006, SE08, SW V2.61 Appendix D CE|VFD-S Series DELTA ELECTRONICS, INC. EC Declaration of Conformity According to the Low Voltage Directive 89/336/EEC and the Amendment Directive 93/68/EEC For the following equipment: AC Motor Drive (Product Name) VFD002S11A/B, VFD004S11A/B, VFD007S11A/B, VFD022S21A/B, VFD002S23B, VFD004S23B, VFD007S23A/B, VFD022S23A/B/D, VFD004S43A/B/E, VFD007S43A/B/E, VFD015S43A/B/D/E/U, VFD022S43A/B/D/E/U, VFD015S21A/B/D/E/U, VFD022S21A/B/D/E/U, VFD007S21A/B/E, VFD004S21A/B/E, VFD015S23A/B/D (Model Name) is herewith confirmed to comply with the requirements set out in the Council Directive 89/336/EEC for electrical equipment used within certain voltage limits and the Amendment Directive 93/68/EEC. For the evaluation of the compliance with this Directive, the following standard was applied: EN61800-3, EN55011, EN61000-6-1, EN61000-6-2, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8 The following manufacturer/importer is responsible for this declaration: Delta Electronics, Inc. (Company Name) 31-1, Shien Pan Road, Kuei San Industrial Zone, Taoyuan Shien, Taiwan 333 (Company Address) D-2 Revision August 2006, SE08, SW V2.61

Frequently asked questions

What makes Elite.Parts unique?

chervon down
At GID Industrial (Elite.Parts' parent company), we specialize in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

What kind of warranty will the VFD007S11B have?

chervon down
Warranties differ by part and by which suppliers we use to procure it for you. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carriers does Elite.Parts work with?

chervon down
Elite.Parts can ship via FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Will Elite.Parts sell to me even though I live outside the USA?

chervon down
Absolutely! We are happy to serve customers regardless of location. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

I have a preferred payment method. Will Elite.Parts accept it?

chervon down
All major credit cards are accepted: Visa, MasterCard, Discover, and American Express. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

5V/12V Voltage Regulator Module

product

Delta ADP-15GH C Power Supply AC Adapter - 5V 3A 5.5mmX2.5mm

product

Delta ADP-25FB AC Power Adapter

product

Delta AFE2000 Series Active Front End Motor Drive Controller

product

Delta AHB1548VHG Fan, 4000RPM, 305.29CFM, 34W Power, 62.0dB-A, 172 x 150 x 50.8 mm Fan, 32.0 ~ 80.0 ...

product

Delta ASB 40 x 40 x 10 mm Series Fans