DALLAS SEMICONDUCTOR DS12C887
Specifications
Clock Format
HH:MM:SS
Clock IC Type
RTC
Date Format
DD:MM:YYYY
Digital IC Case Style
DIP
IC Interface Type
Multiplexed
Memory Configuration
113 x 8
RoHS Compliant
Yes
Supply Voltage Range
4.5V to 5.5V
Datasheet
Extracted Text
DS12885/DS12887/DS12887A/DS12C887/DS12C887A Rev 3; 2/07 Real-Time Clock General Description Features The DS12885, DS12887, and DS12C887 real-time ♦ Drop-In Replacement for IBM AT Computer clocks (RTCs) are designed to be direct replacements Clock/Calendar for the DS1285 and DS1287. The devices provide a real-time clock/calendar, one time-of-day alarm, three ♦ RTC Counts Seconds, Minutes, Hours, Day, Date, maskable interrupts with a common interrupt output, a Month, and Year with Leap Year Compensation programmable square wave, and 114 bytes of battery- Through 2099 backed static RAM (113 bytes in the DS12C887 and DS12C887A). The DS12887 integrates a quartz crystal ♦ Binary or BCD Time Representation and lithium energy source into a 24-pin encapsulated ♦ 12-Hour or 24-Hour Clock with AM and PM in DIP package. The DS12C887 adds a century byte at 12-Hour Mode address 32h. For all devices, the date at the end of the month is automatically adjusted for months with fewer ♦ Daylight Saving Time Option than 31 days, including correction for leap years. The ♦ Selectable Intel or Motorola Bus Timing devices also operate in either 24-hour or 12-hour format with an AM/PM indicator. A precision ♦ Interfaced with Software as 128 RAM Locations temperature-compensated circuit monitors the status of V . If a primary power failure is detected, the device ♦ 14 Bytes of Clock and Control Registers CC automatically switches to a backup supply. A lithium ♦ 114 Bytes of General-Purpose, Battery-Backed coin-cell battery can be connected to the V input BAT RAM (113 Bytes in the DS12C887 and pin on the DS12885 to maintain time and date operation when primary power is absent. The device is accessed DS12C887A) through a multiplexed byte-wide interface, which sup- ♦ RAM Clear Function (DS12885, DS12887A, and ports both Intel and Motorola modes. DS12C887A) Applications ♦ Interrupt Output with Three Independently Embedded Systems Maskable Interrupt Flags Utility Meters ♦ Time-of-Day Alarm Once Per Second to Once Security Systems Per Day Network Hubs, Bridges, and Routers ♦ Periodic Rates from 122μs to 500ms Typical Operating Circuit ♦ End-of-Clock Update Cycle Flag ♦ Programmable Square-Wave Output CRYSTAL V CC ♦ Automatic Power-Fail Detect and Switch Circuitry ♦ Optional 28-Pin PLCC Surface Mount Package or X1 X2 V CC 32-Pin TQFP (DS12885) AS RESET R/W RCLR ♦ Optional Encapsulated DIP (EDIP) Package with Integrated Crystal and Battery (DS12887, DS DS83C520 DS12887A, DS12C887, DS12C887A) DS12885 CS ♦ Optional Industrial Temperature Range Available AD(0–7) SQW ♦ Underwriters Laboratory (UL) Recognized IRQ V BAT MOT GND Pin Configurations and Ordering Information appear at end of data sheet. ______________________________________________ Maxim Integrated Products 1 For pricing, delivery, and ordering information, please contact Maxim/Dallas Direct! at 1-888-629-4642, or visit Maxim’s website at www.maxim-ic.com. Real-Time Clock ABSOLUTE MAXIMUM RATINGS Voltage Range on V Pin Relative to Ground .....-0.3V to +6.0V Storage Temperature Range .............................-55°C to +125°C CC Operating Temperature Range ................................................... Soldering Temperature .......................................See IPC/JEDEC Commercial (noncondensing) .............................0°C to +70°C J-STD-020 Specification (Note 1) Operating Temperature Range ................................................... Soldering Temperature (leads, 10s) ................................+260°C Industrial (noncondensing)...............................-40°C to +85°C Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. DC ELECTRICAL CHARACTERISTICS (V = +4.5V to +5.5V, T = over the operating range, unless otherwise noted.) (Note 2) CC A PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS Supply Voltage V (Note 3) 4.5 5.5 V CC V Input Voltage V (Note 3) 2.5 4.0 V BAT BAT V + CC Input Logic 1 V (Note 3) 2.2 V IH 0.3 Input Logic 0 V (Note 3) -0.3 +0.8 V IL V Power-Supply Current I (Note 4) 15 mA CC CC1 V Standby Current I (Note 5) mA CC CCS Input Leakage I -1.0 +1.0 µA IL I/O Leakage I (Note 6) -1.0 +1.0 µA OL Input Current I (Note 7) -1.0 +500 µA MOT Output at 2.4V I (Note 3) -1.0 mA OH Output at 0.4V I (Note 3) 4.0 mA OL Power-Fail Voltage V (Note 3) 4.0 4.25 4.5 V PF VRT Trip Point VRT 1.3 V TRIP 2 _____________________________________________________________________ DS12885/DS12887/DS12887A/DS12C887/DS12C887A DS12885/DS12887/DS12887A/DS12C887/DS12C887A Real-Time Clock DC ELECTRICAL CHARACTERISTICS (V = 0V, V = 3.0V, T = over the operating range, unless otherwise noted.) (Note 2) CC BAT A PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS V Current (OSC On); BAT I (Note 8) 500 nA BAT T = +25°C, V = 3.0V A BACKUP V Current (Oscillator Off) I (Note 8) 100 nA BAT BATDR AC ELECTRICAL CHARACTERISTICS (V = 4.5V to 5.5V, T = over the operating range.) (Note 2) CC A PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS Cycle Time t 385 DC ns CYC Pulse Width, DS Low or R/W High PW 150 ns EL Pulse Width, DS High or R/W Low PW 125 ns EH Input Rise and Fall t , t 30 ns R F R/W Hold Time t 10 ns RWH R/W Setup Time Before DS/E t 50 ns RWS Chip-Select Setup Time Before t 20 ns CS DS or R/W Chip-Select Hold Time t 0ns CH Read-Data Hold Time t 10 80 ns DHR Write-Data Hold Time t 0ns DHW Address Valid Time to AS Fall t 30 ns ASL Address Hold Time to AS Fall t 10 ns AHL Delay Time DS/E to AS Rise t 20 ns ASD Pulse Width AS High PW 60 ns ASH Delay Time, AS to DS/E Rise t 40 ns ASED Output Data Delay Time from DS t 20 120 ns DDR or R/W Data Setup Time t 100 ns DSW Reset Pulse Width t 5µs RWL IRQ Release from DS t 2µs IRDS IRQ Release from RESET t 2µs IRR _____________________________________________________________________ 3 Real-Time Clock Motorola Bus Read/Write Timing PW ASH t ASED AS t ASD t CYC PW PW EL EH DS t t RWS RWH R/ W t CH t CS CS t DSW t DHW AD0–AD7 WRITE t t ASL AHL t DHR AD0–AD7 READ t DDR Intel Bus Write Timing t CYC AS PW ASH t ASD DS t t ASD ASED R/W PW PW EH EL t CH t CS CS t t ASL t DSW t AHL DHW AD0–AD7 WRITE 4 _____________________________________________________________________ DS12885/DS12887/DS12887A/DS12C887/DS12C887A DS12885/DS12887/DS12887A/DS12C887/DS12C887A Real-Time Clock Intel Bus Read Timing t CYC PW AS ASH t ASD t ASED DS PW PW EL EH t ASD R/W t CH t CS CS t t t t ASL AHL DDR DHR AD0–AD7 IRQ Release Delay Timing DS t RWL RESET IRQ t IRR t IRDS Power-Up/Power-Down Timing V CC V PF(MAX) V PF(MIN) t F t R t RPU t DR DON'T CARE RECOGNIZED RECOGNIZED INPUTS HIGH-Z VALID OUTPUTS VALID _____________________________________________________________________ 5 Real-Time Clock POWER-UP/POWER-DOWN CHARACTERISTICS (T = -40°C to +85°C) (Note 2) A PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS Recovery at Power-Up t 20 200 ms RPU V Fall Time; V to CC PF(MAX) t 300 µs F V PF(MIN) V Rise Time; V to CC PF(MIN) t 0µs R V PF(MAX) DATA RETENTION (T = +25°C) A PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS Expected Data Retention t 10 years DR CAPACITANCE (T = +25°C) (Note 9) A PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS Capacitance on All Input Pins C 5pF IN Except X1 and X2 Capacitance on IRQ, SQW, and C 7pF IO DQ Pins AC TEST CONDITIONS PARAMETER TEST CONDITIONS Input Pulse Levels 0 to 3.0V Output Load Including Scope and Jig 50pF + 1TTL Gate Input and Output Timing Measurement Reference Levels Input/Output: V maximum and V minimum IL IH Input-Pulse Rise and Fall Times 5ns WARNING: Negative undershoots below -0.3V while the part is in battery-backed mode may cause loss of data. Note 1: RTC modules can be successfully processed through conventional wave-soldering techniques as long as temperature exposure to the lithium energy source contained within does not exceed +85°C. However, post-solder cleaning with water- washing techniques is acceptable, provided that ultrasonic vibrations are not used to prevent crystal damage. Note 2: Limits at -40°C are guaranteed by design and not production tested. Note 3: All voltages are referenced to ground. Note 4: All outputs are open. Note 5: Specified with CS = DS = R/W = RESET = V ; MOT, AS, AD0–AD7 = 0; V open. CC BACKUP Note 6: Applies to the AD0 to AD7 pins, the IRQ pin, and the SQW pin when each is in a high-impedance state. Note 7: The MOT pin has an internal 20kΩ pulldown. Note 8: Measured with a 32.768kHz crystal attached to X1 and X2. Note 9: Guaranteed by design. Not production tested. Note 10: Measured with a 50pF capacitance load. 6 _____________________________________________________________________ DS12885/DS12887/DS12887A/DS12C887/DS12C887A DS12885/DS12887/DS12887A/DS12C887/DS12C887A Real-Time Clock Typical Operating Characteristics (V = +5.0V, T = +25°C, unless otherwise noted.) CC A I vs. V BAT1 BAT OSCILLATOR FREQUENCY vs. TEMPERATURE vs. V CC V = 0V +85°C CC 32768.70 300 32768.60 +25°C 32768.50 250 32768.40 0°C +70°C 32768.30 +40°C 200 32768.20 32768.10 -40°C 150 32768.00 2.5 2.8 3.0 3.3 3.5 3.8 4.0 4.5 4.8 5.0 5.3 5.5 V (V) BAT V (V) CC Functional Diagram X1 DIVIDE DIVIDE DIVIDE BY 8 OSC BY 64 BY 64 X2 V CC 16:1 MUX GND POWER SQUARE- SQW CONTROL WAVE GENERATOR V BAT IRQ IRQ DS12885 GENERATOR CS R/W REGISTERS A, B, C, D DS BUS CLOCK/CALENDAR AS UPDATE LOGIC INTERFACE CLOCK/CALENDAR AND MOT ALARM REGISTERS RESET BUFFERED CLOCK/ CALENDAR AND ALARM AD0–AD7 REGISTERS USER RAM RLCR 114 BYTES _____________________________________________________________________ 7 I (nA) BAT DS12885 toc01 FREQUENCY (Hz) DS12885 toc02 Real-Time Clock Pin Description PIN SO, NAME FUNCTION EDIP PLCC TQFP PDIP Motorola or Intel Bus Timing Selector. This pin selects one of two bus types. When connected to V , Motorola bus timing is selected. When connected to GND or CC 1 1 2 29 MOT left disconnected, Intel bus timing is selected. The pin has an internal pulldown resistor. Connections for Standard 32.768kHz Quartz Crystal. The internal oscillator 2— 3 30 X1 circuitry is designed for operation with a crystal having a 6pF specified load capacitance (C ). Pin X1 is the input to the oscillator and can optionally be L connected to an external 32.768kHz oscillator. The output of the internal oscillator, 3— 4 31 X2 pin X2, is floated if an external oscillator is connected to pin X1. Multiplexed, Bidirectional Address/Data Bus. The addresses are presented during the first portion of the bus cycle and latched into the device by the falling edge of AS. Write data is latched by the falling edge of DS (Motorola timing) or the rising 1, 2, 3, edge of R/W (Intel timing). In a read cycle, the device outputs data during the 5–10, AD0– 4–11 4–11 5, 7, 8, 12, 14 AD7 latter portion of DS (DS and R/W high for Motorola timing, DS low and R/W high for 9, 11 Intel timing). The read cycle is terminated and the bus returns to a high- impedance state as DS transitions low in the case of Motorola timing or as DS transitions high in the case of Intel timing. 12, 16 12 15, 20 12, 17 GND Ground Active-Low Chip-Select Input. The chip-select signal must be asserted low for a bus cycle in the device to be accessed. CS must be kept in the active state during DS and AS for Motorola timing and during DS and R/W for Intel timing. Bus cycles 13 13 16 13 CS that take place without asserting CS will latch addresses, but no access occurs. When V is below V volts, the device inhibits access by internally disabling the CC PF CS input. This action protects the RTC data and the RAM data during power outages. Address Strobe Input. A positive-going address-strobe pulse serves to demultiplex the bus. The falling edge of AS causes the address to be latched within the device. The next rising edge that occurs on the AS bus clears the 14 14 17 14 AS address regardless of whether CS is asserted. An address strobe must immediately precede each write or read access. If a write or read is performed with CS deasserted, another address strobe must be performed prior to a read or write access with CS asserted. Read/Write Input. The R/W pin has two modes of operation. When the MOT pin is connected to V for Motorola timing, R/W is at a level that indicates whether the CC current cycle is a read or write. A read cycle is indicated with a high level on R/W 15 15 19 16 R/W while DS is high. A write cycle is indicated when R/W is low during DS. When the MOT pin is connected to GND for Intel timing, the R/W signal is an active-low signal. In this mode, the R/W pin operates in a similar fashion as the write-enable signal (WE) on generic RAMs. Data are latched on the rising edge of the signal. 8 _____________________________________________________________________ DS12885/DS12887/DS12887A/DS12C887/DS12C887A DS12885/DS12887/DS12887A/DS12C887/DS12C887A Real-Time Clock Pin Description (continued) PIN SO, NAME FUNCTION EDIP PLCC TQFP PDIP 4, 6, 10, 2, 3, 1, 11, 15, 20, No Connection. This pin should remain unconnected. Pin 21 is RCLR for the 22 16, 20, 13, 18, N.C. 23, 25, DS12887A/DS12C887A. On the EDIP, these pins are missing by design. 21, 22 26 27, 32 D ata Str ob e or Re ad Inpu t. The D S p i n has tw o mod es of oper ati on dep endi ng on the l evel of the MO T p i n. W hen the M O T pi n i s connected to V , M otor ola b us C C tim i ng i s selec ted. I n this m od e, DS i s a pos iti ve pul se d ur i ng the lat ter p orti on of the b us cycle an d i s cal l ed d ata str ob e. Dur i ng r ead cycl es, D S si g ni fi es the tim e that the 17 17 21 18 DS device is to dr i ve the b i d i r ection al b us. In w r i te cycl es, the trai l i ng ed g e of D S causes the device to l atch the wr i tten data . W hen the M O T pi n i s connected to GN D , Intel b us tim i ng i s sel ected . D S i d entifi es the tim e p eri od w hen the device dr i ves the bus w i th read d ata. In this m od e, the DS p i n op erat es i n a sim i l ar fa shi on as the output - enabl e ( O E ) si g nal on a gen er i c RAM . Active-Low Reset Input. The RESET pin has no effect on the clock, calendar, or RAM. On power-up, the RESET pin can be held low for a time to allow the power supply to stabilize. The amount of time that RESET is held low is dependent on the application. However, if RESET is used on power-up, the time RESET is low should exceed 200ms to ensure that the internal timer that controls the device on power- up has timed out. When RESET is low and V is above V , the following occurs: CC PF A. Periodic interrupt-enable (PIE) bit is cleared to 0. B. Alarm interrupt-enable (AIE) bit is cleared to 0. C. Update-ended interrupt-enable (UIE) bit is cleared to 0. 18 18 22 19 RESET D. Periodic-interrupt flag (PF) bit is cleared to 0. E. Alarm-interrupt flag (AF) bit is cleared to 0. F. Update-ended interrupt flag (UF) bit is cleared to 0. G. Interrupt-request status flag (IRQF) bit is cleared to 0. H. IRQ pin is in the high-impedance state. I. The device is not accessible until RESET is returned high. J. Square-wave output-enable (SQWE) bit is cleared to 0. In a typical application, RESET can be connected to V . This connection allows CC the device to go in and out of power fail without affecting any of the control registers. _____________________________________________________________________ 9 Real-Time Clock Pin Description (continued) PIN SO, NAME FUNCTION EDIP PLCC TQFP PDIP Active-Low Interrupt Request Output. The IRQ pin is an active-low output of the device that can be used as an interrupt input to a processor. The IRQ output remains low as long as the status bit causing the interrupt is present and the corresponding interrupt-enable bit is set. The processor program normally 19 19 23 21 IRQ reads the C register to clear the IRQ pin. The RESET pin also clears pending interrupts. When no interrupt conditions are present, the IRQ level is in the high- impedance state. Multiple interrupting devices can be connected to an IRQ bus, provided that they are all open drain. The IRQ pin is an open-drain output and requires an external pullup resistor to V . CC Connection for a Primary Battery. (DS12885 Only.) Battery voltage must be held between the minimum and maximum limits for proper operation. If a backup supply is not supplied, V must be grounded. Connect the battery directly to BAT 20 — 24 22 V BAT the V pin. Diodes in series between the V pin and the battery may BAT BAT prevent proper operation. UL recognized to ensure against reverse charging when used with a lithium battery. Active-Low RAM Clear. The RCLR pin is used to clear (set to logic 1) all the general-purpose RAM, but does not affect the RAM associated with the RTC. To 21 clear the RAM, RCLR must be forced to an input logic 0 during battery-backup 21 (DS12887A/ 25 24 RCLR mode when V is not applied. The RCLR function is designed to be used CC DS12C887A) through a human interface (shorting to ground manually or by a switch) and not to be driven with external buffers. This pin is internally pulled up. Do not use an external pullup resistor on this pin. Square-Wave Output. The SQW pin can output a signal from one of 13 taps provided by the 15 internal divider stages of the RTC. The frequency of the 23 23 27 26 SQW SQW pin can be changed by programming Register A, as shown in Table 1. The SQW signal can be turned on and off using the SQWE bit in Register B. The SQW signal is not available when V is less than V . CC PF DC Power Pin for Primary Power Supply. When V is applied within normal CC 24 24 28 28 V limits, the device is fully accessible and data can be written and read. When CC V is below V reads and writes are inhibited. CC PF 10 ____________________________________________________________________ DS12885/DS12887/DS12887A/DS12C887/DS12C887A DS12885/DS12887/DS12887A/DS12C887/DS12C887A Real-Time Clock Detailed Description Table 1. Crystal Specifications* The DS12885 family of RTCs provide 14 bytes of real- PARAMETER SYMBOL MIN TYP MAX UNITS time clock/calendar, alarm, and control/status registers Nominal and 114 bytes (113 bytes for DS12C887 and f 32.768 kHz O Frequency DS12C887A) of nonvolatile, battery-backed static RAM. A time-of-day alarm, three maskable interrupts with a Series ESR 50 kΩ common interrupt output, and a programmable square- Resistance wave output are available. The devices also operate in Load either 24-hour or 12-hour format with an AM/PM indica- C 6pF L Capacitance tor. A precision temperature-compensated circuit moni- tors the status of V . If a primary power-supply failure CC *The crystal, traces, and crystal input pins should be isolated is detected, the devices automatically switch to a back- from RF generating signals. Refer to Application Note 58: Crystal Considerations for Dallas Real-Time Clocks for up supply. The backup supply input supports a primary additional specifications. battery, such as lithium coin cell. The devices are accessed through a multiplexed address/data bus that supports Intel and Motorola modes. Oscillator Circuit The DS12885 uses an external 32.768kHz crystal. The COUNTDOWN oscillator circuit does not require any external resistors CHAIN or capacitors to operate. Table 1 specifies several crys- tal parameters for the external crystal. Figure 1 shows a functional schematic of the oscillator circuit. An enable bit in the control register controls the oscillator. C1C 2 L L RTC REGISTERS Oscillator startup times are highly dependent upon crystal characteristics, PC board leakage, and layout. High ESR and excessive capacitive loads are the major DS12885 contributors to long startup times. A circuit using a crystal with the recommended characteristics and X1 X2 proper layout usually starts within one second. An external 32.768kHz oscillator can also drive the CRYSTAL DS12885. In this configuration, the X1 pin is connected to the external oscillator signal and the X2 pin is floated. Figure 1. Oscillator Circuit Showing Internal Bias Network ____________________________________________________________________ 11 Real-Time Clock Clock Accuracy LOCAL GROUND PLANE (TOP LAYER) The accuracy of the clock is dependent upon the accu- racy of the crystal and the accuracy of the match between the capacitive load of the oscillator circuit and X1 the capacitive load for which the crystal was trimmed. CRYSTAL Additional error is added by crystal frequency drift X2 caused by temperature shifts. External circuit noise cou- pled into the oscillator circuit can result in the clock run- ning fast. Figure 2 shows a typical PC board layout for isolation of the crystal and oscillator from noise. Refer to NOTE: AVOID ROUTING SIGNAL LINES IN THE CROSSHATCHED AREA Application Note 58: Crystal Considerations with Dallas (UPPER LEFT QUADRANT) OF Real-Time Clocks for more detailed information. THE PACKAGE UNLESS THERE IS GND A GROUND PLANE BETWEEN THE SIGNAL LINE AND THE DEVICE PACKAGE. Clock Accuracy for DS12887, DS12887A, DS12C887, DS12C887A Only Figure 2. Layout Example The encapsulated DIP modules are trimmed at the fac- tory to an accuracy of ±1 minute per month at +25°C. automatically adjusted for months with fewer than 31 Power-Down/Power-Up days, including correction for leap years. Considerations Before writing the internal time, calendar, and alarm reg- isters, the SET bit in Register B should be written to logic The real-time clock continues to operate, and the RAM, 1 to prevent updates from occurring while access is time, calendar, and alarm memory locations remain being attempted. In addition to writing the 10 time, calen- nonvolatile regardless of the V input level. V must CC BAT dar, and alarm registers in a selected format (binary or remain within the minimum and maximum limits when BCD), the data mode bit (DM) of Register B must be set V is not applied. When V is applied and exceeds CC CC to the appropriate logic level. All 10 time, calendar, and V (power-fail trip point), the device becomes accessi- PF alarm bytes must use the same data mode. The SET bit ble after t —if the oscillator is running and the oscil- REC in Register B should be cleared after the data mode bit lator countdown chain is not in reset (Register A). This has been written to allow the RTC to update the time and time allows the system to stablize after power is calendar bytes. Once initialized, the RTC makes all applied. If the oscillator is not enabled, the oscillator- updates in the selected mode. The data mode cannot be enable bit is enabled on power-up, and the device changed without reinitializing the 10 data bytes. Tables becomes immediately accessible. 2A and 2B show the BCD and binary formats of the time, Time, Calendar, and Alarm calendar, and alarm locations. Locations The 24-12 bit cannot be changed without reinitializing the hour locations. When the 12-hour format is selected, the The time and calendar information is obtained by read- higher-order bit of the hours byte represents PM when it ing the appropriate register bytes. The time, calendar, is logic 1. The time, calendar, and alarm bytes are always and alarm are set or initialized by writing the appropri- accessible because they are double-buffered. Once per ate register bytes. Invalid time or date entries result in second the seven bytes are advanced by one second undefined operation. The contents of the 10 time, cal- and checked for an alarm condition. endar, and alarm bytes can be either binary or binary- coded decimal (BCD) format. If a read of the time and calendar data occurs during an update, a problem exists where seconds, minutes, The day-of-week register increments at midnight, incre- hours, etc., may not correlate. The probability of read- menting from 1 through 7. The day-of-week register is ing incorrect time and calendar data is low. Several used by the daylight saving function, so the value 1 is methods of avoiding any possible incorrect time and defined as Sunday. The date at the end of the month is calendar reads are covered later in this text. 12 ____________________________________________________________________ DS12885/DS12887/DS12887A/DS12C887/DS12C887A DS12885/DS12887/DS12887A/DS12C887/DS12C887A Real-Time Clock The three alarm bytes can be used in two ways. First, condition when at logic 1. An alarm is generated each when the alarm time is written in the appropriate hours, hour when the don’t-care bits are set in the hours byte. minutes, and seconds alarm locations, the alarm inter- Similarly, an alarm is generated every minute with rupt is initiated at the specified time each day, if the don’t-care codes in the hours and minute alarm bytes. alarm-enable bit is high. In this mode, the “0” bits in the The don’t-care codes in all three alarm bytes create an alarm registers and the corresponding time registers interrupt every second. must always be written to 0 (Table 2A and 2B). Writing All 128 bytes can be directly written or read, except for the 0 bits in the alarm and/or time registers to 1 can the following: result in undefined operation. 1) Registers C and D are read-only. The second use condition is to insert a “don’t care” 2) Bit 7 of register A is read-only. state in one or more of the three alarm bytes. The don’t- care code is any hexadecimal value from C0 to FF. The 3) The MSB of the seconds byte is read-only. two most significant bits of each byte set the don’t-care Table 2A. Time, Calendar, and Alarm Data Modes—BCD Mode (DM = 0) ADDRESS BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 FUNCTION RANGE 00H 0 10 Seconds Seconds Seconds 00–59 01H 0 10 Seconds Seconds Seconds Alarm 00–59 02H 0 10 Minutes Minutes Minutes 00–59 03H 0 10 Minutes Minutes Minutes Alarm 00–59 AM/PM 0 10 Hours 1–12 +AM/PM 04H 0 Hours Hours 00–23 0 10 Hours AM/PM 0 10 Hours 1–12 +AM/PM 05H 0 Hours Hours Alarm 00–23 0 10 Hours 06H 0 0 0 0 0 Day Day 01–07 07H 0 0 10 Date Date Date 01–31 08H 0 0 0 10 Months Month Month 01–12 09H 10 Years Year Year 00–99 0AH UIP DV2 DV1 DV0 RS3 RS2 RS1 RS0 Control — 0BH SET PIE AIE UIE SQWE DM 24/12 DSE Control — 0CH IRQF PF AF UF 0 0 0 0 Control — 0DH VRT 0 0 0 0 0 0 0 Control — 0EH-31H X X X X X X X X RAM — 32H 10 Century Century Century* 00–99 33H-7FH X X X X X X X X RAM — X = Read/Write Bit. *DS12C887, DS12C887A only. General-purpose RAM on DS12885, DS12887, and DS12887A. Note: Unless otherwise specified, the state of the registers is not defined when power is first applied. Except for the seconds regis- ter, 0 bits in the time and date registers can be written to 1, but may be modified when the clock updates. 0 bits should always be written to 0 except for alarm mask bits. ____________________________________________________________________ 13 Real-Time Clock Table 2B. Time, Calendar, and Alarm Data Modes—Binary Mode (DM = 1) ADDRESS BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 FUNCTION RANGE 00H 0 0 Seconds Seconds 00–3B 01H 0 0 Seconds Seconds Alarm 00–3B 02H 0 0 Minutes Minutes 00–3B 03H 0 0 Minutes Minutes Alarm 00–3B AM/PM 0 Hours 01–0C +AM/PM 04H 00 Hours 00–17 0 Hours AM/PM 0 Hours 0 01–0C +AM/PM 05H 0 Hours Alarm 00–17 0 Hours 06H 0 0 0 0 0 Day Day 01–07 07H 0 0 0 Date Date 01–1F 08H 0 0 0 0 Month Month 01–0C 09H 0 Year Year 00–63 0AH UIP DV2 DV1 DV0 RS3 RS2 RS1 RS0 Control — 0BH SET PIE AIE UIE SQWE DM 24/12 DSE Control — 0CH IRQF PF AF UF 0 0 0 0 Control — 0DH VRT 0 0 0 0 0 0 0 Control — 0EH-31H X X X X X X X X RAM — 32H N/A N/A Century* — 33H-7FH X X X X X X X X RAM — X = Read/Write Bit. *DS12C887, DS12C887A only. General-purpose RAM on DS12885, DS12887, and DS12887A. Note: Unless otherwise specified, the state of the registers is not defined when power is first applied. Except for the seconds regis- ter, 0 bits in the time and date registers can be written to 1, but may be modified when the clock updates. 0 bits should always be written to 0 except for alarm mask bits. 14 ____________________________________________________________________ DS12885/DS12887/DS12887A/DS12C887/DS12C887A DS12885/DS12887/DS12887A/DS12C887/DS12C887A Real-Time Clock Control Registers The real-time clocks have four control registers that are accessible at all times, even during the update cycle. Control Register A MSB LSB BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 UIP DV2 DV1 DV0 RS3 RS2 RS1 RS0 Bit 7: Update-In-Progress (UIP). This bit is a status Bits 3 to 0: Rate Selector (RS3, RS2, RS1, RS0). flag that can be monitored. When the UIP bit is a 1, the These four rate-selection bits select one of the 13 taps update transfer occurs soon. When UIP is a 0, the on the 15-stage divider or disable the divider output. update transfer does not occur for at least 244µs. The The tap selected can be used to generate an output time, calendar, and alarm information in RAM is fully square wave (SQW pin) and/or a periodic interrupt. The available for access when the UIP bit is 0. The UIP bit is user can do one of the following: read-only and is not affected by RESET. Writing the 1) Enable the interrupt with the PIE bit; SET bit in Register B to a 1 inhibits any update transfer 2) Enable the SQW output pin with the SQWE bit; and clears the UIP status bit. 3) Enable both at the same time and the same rate; Bits 6, 5, and 4: DV2, DV1, DV0. These three bits are or used to turn the oscillator on or off and to reset the countdown chain. A pattern of 010 is the only combina- 4) Enable neither. tion of bits that turn the oscillator on and allow the RTC Table 3 lists the periodic interrupt rates and the square- to keep time. A pattern of 11x enables the oscillator but wave frequencies that can be chosen with the RS bits. holds the countdown chain in reset. The next update These four read/write bits are not affected by RESET. occurs at 500ms after a pattern of 010 is written to DV0, DV1, and DV2. ____________________________________________________________________ 15 Real-Time Clock Control Register B MSB LSB BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 SET PIE AIE UIE SQWE DM 24/12 DSE Bit 7: SET. When the SET bit is 0, the update transfer Bit 3: Square-Wave Enable (SQWE). When this bit is functions normally by advancing the counts once per set to 1, a square-wave signal at the frequency set by second. When the SET bit is written to 1, any update the rate-selection bits RS3–RS0 is driven out on the SQW transfer is inhibited, and the program can initialize the pin. When the SQWE bit is set to 0, the SQW pin is held time and calendar bytes without an update occurring in low. SQWE is a read/write bit and is cleared by RESET. the midst of initializing. Read cycles can be executed in SQWE is low if disabled, and is high impedance when a similar manner. SET is a read/write bit and is not V is below V . SQWE is cleared to 0 on RESET. CC PF affected by RESET or internal functions of the device. Bit 2: Data Mode (DM). This bit indicates whether time Bit 6: Periodic Interrupt Enable (PIE). The PIE bit is a and calendar information is in binary or BCD format. read/write bit that allows the periodic interrupt flag (PF) bit The DM bit is set by the program to the appropriate for- in Register C to drive the IRQ pin low. When the PIE bit is mat and can be read as required. This bit is not modi- set to 1, periodic interrupts are generated by driving the fied by internal functions or RESET. A 1 in DM signifies IRQ pin low at a rate specified by the RS3–RS0 bits of binary data, while a 0 in DM specifies BCD data. Register A. A 0 in the PIE bit blocks the IRQ output from Bit 1: 24/12. The 24/12 control bit establishes the for- being driven by a periodic interrupt, but the PF bit is still mat of the hours byte. A 1 indicates the 24-hour mode set at the periodic rate. PIE is not modified by any internal and a 0 indicates the 12-hour mode. This bit is device functions, but is cleared to 0 on RESET. read/write and is not affected by internal functions or Bit 5: Alarm Interrupt Enable (AIE). This bit is a RESET. read/write bit that, when set to 1, permits the alarm flag Bit 0: Daylight Saving Enable (DSE). This bit is a (AF) bit in Register C to assert IRQ. An alarm interrupt read/write bit that enables two daylight saving adjust- occurs for each second that the three time bytes equal ments when DSE is set to 1. On the first Sunday in the three alarm bytes, including a don’t-care alarm April, the time increments from 1:59:59 AM to 3:00:00 code of binary 11XXXXXX. The AF bit does not initiate AM. On the last Sunday in October when the time first the IRQ signal when the AIE bit is set to 0. The internal reaches 1:59:59 AM, it changes to 1:00:00 AM. When functions of the device do not affect the AIE bit, but is DSE is enabled, the internal logic test for the first/last cleared to 0 on RESET. Sunday condition at midnight. If the DSE bit is not set Bit 4: Update-Ended Interrupt Enable (UIE). This bit is when the test occurs, the daylight saving function does a read/write bit that enables the update-end flag (UF) not operate correctly. These adjustments do not occur bit in Register C to assert IRQ. The RESET pin going when the DSE bit is 0. This bit is not affected by internal low or the SET bit going high clears the UIE bit. functions or RESET. The internal functions of the device do not affect the UIE bit, but is cleared to 0 on RESET. 16 ____________________________________________________________________ DS12885/DS12887/DS12887A/DS12C887/DS12C887A DS12885/DS12887/DS12887A/DS12C887/DS12C887A Real-Time Clock Control Register C MSB LSB BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 IRQF PF AF UF 0 0 0 0 Bit 7: Interrupt Request Flag (IRQF). This bit is set to Bit 5: Alarm Interrupt Flag (AF). A 1 in the AF bit indi- 1 when any of the following are true: cates that the current time has matched the alarm time. If the AIE bit is also 1, the IRQ pin goes low and a 1 PF = PIE = 1 appears in the IRQF bit. This bit can be cleared by AF = AIE = 1 reading Register C or with a RESET. UF = UIE = 1 Bit 5: Update-Ended Interrupt Flag (UF). This bit is Any time the IRQF bit is 1, the IRQ pin is driven low. set after each update cycle. When the UIE bit is set to This bit can be cleared by reading Register C or with a 1, the 1 in UF causes the IRQF bit to be a 1, which RESET. asserts the IRQ pin. This bit can be cleared by reading Register C or with a RESET. Bit 6: Periodic Interrupt Flag (PF). This bit is read- only and is set to 1 when an edge is detected on the Bits 3 to 0: Unused. These bits are unused in Register selected tap of the divider chain. The RS3 through RS0 C. These bits always read 0 and cannot be written. bits establish the periodic rate. PF is set to 1 indepen- dent of the state of the PIE bit. When both PF and PIE are 1s, the IRQ signal is active and sets the IRQF bit. This bit can be cleared by reading Register C or with a RESET. Control Register D MSB LSB BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 VRT 0000000 Bit 7: Valid RAM and Time (VRT). This bit indicates the RTC data and RAM data are questionable. This bit the condition of the battery connected to the V pin. is unaffected by RESET. BAT This bit is not writeable and should always be 1 when Bits 6 to 0: Unused. The remaining bits of Register D read. If a 0 is ever present, an exhausted internal lithi- are not usable. They cannot be written and they always um energy source is indicated and both the contents of read 0. ____________________________________________________________________ 17 Real-Time Clock when reading Register C. Each used flag bit should be Century Register examined when Register C is read to ensure that no (DS12C887/DS12C887A Only) interrupts are lost. The century register at location 32h is a BCD register The second flag bit method is used with fully enabled designed to automatically load the BCD value 20 as the interrupts. When an interrupt flag bit is set and the cor- year register changes from 99 to 00. The MSB of this responding interrupt-enable bit is also set, the IRQ pin is register is not affected when the load of 20 occurs, and asserted low. IRQ is asserted as long as at least one of remains at the value written by the user. the three interrupt sources has its flag and enable bits set. The IRQF bit in Register C is a 1 whenever the IRQ Nonvolatile RAM (NV RAM) pin is driven low. Determination that the RTC initiated an The general-purpose NV RAM bytes are not dedicated interrupt is accomplished by reading Register C. A logic to any special function within the device. They can be 1 in bit 7 (IRQF bit) indicates that one or more interrupts used by the processor program as battery-backed have been initiated by the device. The act of reading memory and are fully available during the update cycle. Register C clears all active flag bits and the IRQF bit. Interrupts Oscillator Control Bits The RTC family includes three separate, fully automatic When the DS12887, DS12887A, DS12C887, and sources of interrupt for a processor. The alarm interrupt DS12C887A are shipped from the factory, the internal can be programmed to occur at rates from once per oscillator is turned off. This prevents the lithium energy second to once per day. The periodic interrupt can be cell from being used until the device is installed in a selected for rates from 500ms to 122µs. The update- system. ended interrupt can be used to indicate to the program A pattern of 010 in bits 4 to 6 of Register A turns the that an update cycle is complete. Each of these inde- oscillator on and enables the countdown chain. A pat- pendent interrupt conditions is described in greater tern of 11x (DV2 = 1, DV1 = 1, DV0 = X) turns the oscil- detail in other sections of this text. lator on, but holds the countdown chain of the oscillator The processor program can select which interrupts, if in reset. All other combinations of bits 4 to 6 keep the any, are to be used. Three bits in Register B enable the oscillator off. interrupts. Writing a logic 1 to an interrupt-enable bit permits that interrupt to be initiated when the event Square-Wave Output Selection occurs. A 0 in an interrupt-enable bit prohibits the IRQ Thirteen of the 15 divider taps are made available to a 1- pin from being asserted from that interrupt condition. If of-16 multiplexer, as shown in the functional diagram. an interrupt flag is already set when an interrupt is The square-wave and periodic-interrupt generators enabled, IRQ is immediately set at an active level, share the output of the multiplexer. The RS0–RS3 bits in although the interrupt initiating the event may have Register A establish the output frequency of the multi- occurred earlier. As a result, there are cases where the plexer (see Table 1). Once the frequency is selected, the program should clear such earlier initiated interrupts output of the SQW pin can be turned on and off under before first enabling new interrupts. program control with the square-wave enable bit, SQWE. When an interrupt event occurs, the relating flag bit is Periodic Interrupt Selection set to logic 1 in Register C. These flag bits are set inde- pendent of the state of the corresponding enable bit in The periodic interrupt causes the IRQ pin to go to an Register B. The flag bit can be used in a polling mode active state from once every 500ms to once every 122µs. without enabling the corresponding enable bits. The This function is separate from the alarm interrupt, which interrupt flag bit is a status bit that software can interro- can be output from once per second to once per day. gate as necessary. When a flag is set, an indication is The periodic interrupt rate is selected using the same given to software that an interrupt event has occurred Register A bits that select the square-wave frequency since the flag bit was last read; however, care should (Table 1). Changing the Register A bits affects the be taken when using the flag bits as they are cleared square-wave frequency and the periodic-interrupt out- each time Register C is read. Double latching is includ- put. However, each function has a separate enable bit in ed with Register C so that bits that are set remain sta- Register B. The SQWE bit controls the square-wave out- ble throughout the read cycle. All bits that are set (high) put. Similarly, the PIE bit in Register B enables the peri- are cleared when read, and new interrupts that are odic interrupt. The periodic interrupt can be used with pending during the read cycle are held until after the software counters to measure inputs, create output inter- cycle is completed. One, two, or three bits can be set vals, or await the next needed software function. 18 ____________________________________________________________________ DS12885/DS12887/DS12887A/DS12C887/DS12C887A DS12885/DS12887/DS12887A/DS12C887/DS12C887A Real-Time Clock sponding time byte and issues an alarm if a match or if Table 3. Periodic Interrupt Rate and a don’t-care code is present in all three positions. Square-Wave Output Frequency There are three methods that can handle RTC access SELECT BITS t PERIODIC PI that avoid any possibility of accessing inconsistent time SQW OUTPUT REGISTER A INTERRUPT and calendar data. The first method uses the update- FREQUENCY RATE RS3 RS2 RS1 RS0 ended interrupt. If enabled, an interrupt occurs after every update cycle that indicates over 999ms is avail- 0 0 0 0 None None able to read valid time and date information. If this 0 0 0 1 3.90625ms 256Hz interrupt is used, the IRQF bit in Register C should be 0 0 1 0 7.8125ms 128Hz cleared before leaving the interrupt routine. 0 0 1 1 122.070µs 8.192kHz A second method uses the update-in-progress bit (UIP) 0 1 0 0 244.141µs 4.096kHz in Register A to determine if the update cycle is in 0 1 0 1 488.281µs 2.048kHz progress. The UIP bit pulses once per second. After the UIP bit goes high, the update transfer occurs 244µs 0 1 1 0 976.5625µs 1.024kHz later. If a low is read on the UIP bit, the user has at least 0 1 1 1 1.953125ms 512Hz 244µs before the time/calendar data is changed. 1 0 0 0 3.90625ms 256Hz Therefore, the user should avoid interrupt service rou- 1 0 0 1 7.8125ms 128Hz tines that would cause the time needed to read valid time/calendar data to exceed 244µs. 1 0 1 0 15.625ms 64Hz The third method uses a periodic interrupt to determine if 1 0 1 1 31.25ms 32Hz an update cycle is in progress. The UIP bit in Register A 1 1 0 0 62.5ms 16Hz is set high between the setting of the PF bit in Register C 1 1 0 1 125ms 8Hz (Figure 3). Periodic interrupts that occur at a rate greater 1 1 1 0 250ms 4Hz than t allow valid time and date information to be BUC reached at each occurrence of the periodic interrupt. 1 1 1 1 500ms 2Hz The reads should be complete within one (t + t ) PI/2 BUC Update Cycle to ensure that data is not read during the update cycle. The device executes an update cycle once per second Handling, PC Board Layout, regardless of the SET bit in Register B. When the SET bit in Register B is set to 1, the user copy of the double- and Assembly buffered time, calendar, and alarm bytes is frozen and The EDIP module can be successfully processed does not update as the time increments. However, the through conventional wave-soldering techniques so long time countdown chain continues to update the internal as temperature exposure to the lithium energy source copy of the buffer. This feature allows time to maintain does not exceed +85°C. Post-solder cleaning with water- accuracy independent of reading or writing the time, washing techniques is acceptable, provided that ultra- calendar, and alarm buffers, and also guarantees that sonic vibration is not used. Such cleaning can damage time and calendar information is consistent. The update the crystal. cycle also compares each alarm byte with the corre- 1 SECOND UIP t BUC UF t t P1/2 P1/2 PF t PI t = DELAY TIME BEFORE UPDATE BUC CYCLE = 244μs Figure 3. UIP and Periodic Interrupt Timing ____________________________________________________________________ 19 Real-Time Clock Pin Configurations TOP VIEW MOT 1 24 V MOT 1 24 V CC CC X1 2 23 SQW N.C. 2 23 SQW X2 3 22 N.C. N.C. 3 22 N.C. N.C. AD0 4 21 RCLR AD0 4 21 (RCLR) AD1 5 20 V AD1 5 20 N.C. BAT DS12885 DS12887 AD2 6 19 IRQ AD2 6 19 IRQ DS12885S DS12887A AD3 7 18 RESET AD3 7 18 RESET DS12C887 DS12C887A AD4 8 17 DS AD4 8 17 DS AD5 9 16 GND AD5 9 16 N.C. AD6 10 15 R/W AD6 10 15 R/W AD7 11 14 AS AD7 11 14 AS GND 12 13 CS GND 12 13 CS SO, PDIP EDIP ( ) FOR THE DS12887A/DS12C887A. N.C. 26 18 N.C. AS SQW 27 17 CS VCC 28 16 GND N.C. 1 15 DS12885Q AD7 MOT 2 14 3 X1 13 N.C. X2 4 12 AD6 PLCC NOTE: THE DS12887A AND DS12C887A CANNOT BE STORED OR SHIPPED IN CONDUCTIVE MATERIAL THAT WILL GIVE A CONTINUITY PATH BETWEEN THE RAM CLEAR PIN AND GROUND. 20 ____________________________________________________________________ DS12885/DS12887/DS12887A/DS12C887/DS12C887A AD0 5 25 RCLR V AD1 6 24 BAT AD2 7 23 IRQ 22 RESET AD3 8 AD4 9 21 DS AD5 10 GND 20 N.C. 11 19 R/W DS12885/DS12887/DS12887A/DS12C887/DS12C887A Real-Time Clock Pin Configurations (continued) Ordering Information PIN- TOP PART TEMP RANGE TOP VIEW PACKAGE MARK* DS12885 0°C to +70°C 24 PDIP DS12885 DS12885+ 0°C to +70°C 24 PDIP DS12885 32 31 30 29 28 27 26 25 DS12885N -40°C to +85°C 24 PDIP DS12885 DS12885N+ -40°C to +85°C 24 PDIP DS12885 AD0 1 24 RCLR DS12885Q 0°C to +70°C 28 PLCC DS12885Q AD1 2 23 N.C. DS12885Q+ 0°C to +70°C 28 PLCC DS12885Q 22 V AD2 3 BAT DS12885QN -40°C to +85°C 28 PLCC DS12885Q N.C. 4 21 IRQ DS12885QN+ -40°C to +85°C 28 PLCC DS12885Q DS12885T AD3 5 20 N.C. DS12885Q/T&R 0°C to +70°C 28 PLCC DS12885Q DS12885Q+T&R 0°C to +70°C 28 PLCC DS12885Q N.C. 6 19 RESET DS12885QN/T&R -40°C to +85°C 28 PLCC DS12885Q AD4 7 18 DS DS12885QN+T&R -40°C to +85°C 28 PLCC DS12885Q AD5 8 17 GND 24 SO DS12885S 0°C to +70°C DS12885S (300 mils) 9 10 11 12 13 14 15 16 24 SO DS12885S+ 0°C to +70°C DS12885S (300 mils) TQFP 24 SO DS12885SN -40°C to +85°C DS12885S (300 mils) 24 SO DS12885SN+ -40°C to +85°C DS12885S Thermal Information (300 mils) 24 SO PACKAGE THETA-JA (°C/W) THETA-JC (°C/W) DS12885S/T&R 0°C to +70°C DS12885S (300 mils) PDIP 75 30 24 SO SO 105 22 DS12885S+T&R 0°C to +70°C DS12885S (300 mils) PLCC 95 25 DS12885T 0°C to +70°C 32 TQFP DS12885 DS12885T+ 0°C to +70°C 32 TQFP DS12885 Package Information DS12885TN -40°C to +85°C 32 TQFP DS12885 PIN-PACKAGE DOCUMENT NO. DS12885TN+ -40°C to +85°C 32 TQFP DS12885 56-G4009-001 24 SO (300 mils) DS12885T/T&R 0°C to +70°C 32 TQFP DS12885 24 PDIP 56-G5000-003 DS12887 0°C to +70°C 24 EDIP DS12887 24 EDIP 56-G0001-001 DS12887+ 0°C to +70°C 24 EDIP DS12887 56-G4001-001 28 PLCC DS12887A 0°C to +70°C 24 EDIP DS12887A 32 TQFP 56-G4004-001 DS12887A+ 0°C to +70°C 24 EDIP DS12887A DS12C887 0°C to +70°C 24 EDIP DS12C887 DS12C887+ 0°C to +70°C 24 EDIP DS12C887 Chip Information DS12C887A DS12C887A 0°C to +70°C 24 EDIP TRANSISTOR COUNT: 17,000 DS12C887A+ 0°C to +70°C 24 EDIP DS12C887A PROCESS: CMOS +Denotes a lead-free/RoHS-compliant device. SUBSTRATE CONNECTED TO GROUND T&R = Tape-and-reel. *A “+” anywhere on the top mark indicates a lead-free device, and an “N” indicates an industrial temperature range device. ____________________________________________________________________ 21 N.C. AD6 N.C. X2 AD7 X1 GND MOT CS V CC AS N.C. N.C. SQW R/W N.C. Real-Time Clock Revision History Rev 0; 6/05: Initial release of combined data sheet. Rev 1; 4/06: Corrected Intel Bus Write Timing diagram (page 4), Intel Bus Read Timing, IRQ Release Delay Timing, and Power-Up/Down Timing diagrams (page 5), and Functional Diagram (page 7). Added Handling, PC Board Layout, and Assembly section (page 20). Rev 2; 5/06: Corrected Intel Bus Write Timing diagram (page 4); added PLCC pin description information (pages 8, 9, and 10); changed pin 16 from N.C. to GND for the SO, PDIP packages (pages 8, 9, and 20). Rev 3; 2/07: Corrected Intel Bus Write Timing diagram (page 4); updated Ordering Information (page 20); added Package Information table (page 20); removed package drawings (pages 22 to 27). Maxim cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim product. No circuit patent licenses are implied. Maxim reserves the right to change the circuitry and specifications without notice at any time. 22 ____________________Maxim Integrated Products, 120 San Gabriel Drive, Sunnyvale, CA 94086 408-737-7600 © 2007 Maxim Integrated Products is a registered trademark of Maxim Integrated Products, Inc. is a registered trademark of Dallas Semiconductor Corporation. Quijano DS12885/DS12887/DS12887A/DS12C887/DS12C887A
Frequently asked questions
What makes Elite.Parts unique?
What kind of warranty will the DS12C887 have?
Which carriers does Elite.Parts work with?
Will Elite.Parts sell to me even though I live outside the USA?
I have a preferred payment method. Will Elite.Parts accept it?
Why buy from GID?
Quality
We are industry veterans who take pride in our work
Protection
Avoid the dangers of risky trading in the gray market
Access
Our network of suppliers is ready and at your disposal
Savings
Maintain legacy systems to prevent costly downtime
Speed
Time is of the essence, and we are respectful of yours
Manufacturers







What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods