Elite.Parts Manufacturers C CROUZET 88970162
About product Specifications Datasheet FAQ

CROUZET 88970162

Description

Crouzet 88970162 Relay - Controller Expandable Relay

Part Number

88970162

Price

Request Quote

Manufacturer

CROUZET

Lead Time

Request Quote

Category

ELECTROMECHANICAL & INDUSTRIAL CONTROL

Specifications

Certifications

UL, CSA; GL : except for 88 970 32x (pending)

Conformity to standards (with the low voltage directive and EMC directive)

In accordance with 73/23/EEC : EN (IEC) 61131-2 (Open equipment)

Conformity with the EMC directive

In accordance with 89/336/EEC : EN (IEC) 61131-2 (Zone B); EN (IEC) 61000-6-2, EN (IEC) 61000-6-3 (*); EN (IEC) 61000-6-4; (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B : using in metallic cabinet)

Earthing

None

Max operating Altitude

Operation:2000 m; Transport:3,048 m

Mechanical resistance

Immunity to vibrations IEC/EN 60068-2-6, Fc test; Immunity to shock IEC/EN 60068-2-27, Fatest

Overvoltage category

3 in accordance with IEC/EN 60664-1

Pollution

Degree : 2 in accordance with IEC/EN 61131-2

Protection rating

In accordance with IEC/EN 60529:IP40 on front panel, IP20 on terminal block

Datasheet

pdf file

Crouzet=2264519=datasheet1-750978091.pdf

130 KiB

Extracted Text

05/06/2012 www.crouzet.com "Expandable" range with display XD26 Part number 88970162  "High-performance" expandable solution with display  Extended memory : 120 lines in LADDER language and up to 700 "typical" blocks in FBD language  LCD with 4 lines of 18 characters and configurable backlighting  Selective parameter setting : You can choose the parameters that can be adjusted on the front panel  Analogue inputs 0-10 V DC or 0-20 mA/Pt 100 with converters (see page 50)  Open to XN network communication extensions and digital I/O or analogue extensions     General environment characteristics for CB, CD, XD, XB, XR and XE product types Certifications UL, CSA GL : except for 88 970 32x (pending) Conformity to standards (with the low voltage directive In accordance with 73/23/EEC : and EMC directive) EN (IEC) 61131-2 (Open equipment) Conformity with the EMC directive In accordance with 89/336/EEC : EN (IEC) 61131-2 (Zone B) EN (IEC) 61000-6-2, EN (IEC) 61000-6-3 (*) EN (IEC) 61000-6-4 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B : using in metallic cabinet) Earthing None Protection rating In accordance with IEC/EN 60529 : IP40 on front panel IP20 on terminal block Overvoltage category 3 in accordance with IEC/EN 60664-1 Pollution Degree : 2 in accordance with IEC/EN 61131-2 Max operating Altitude Operation : 2000 m Transport : 3,048 m Mechanical resistance Immunity to vibrations IEC/EN 60068-2-6, Fc test Immunity to shock IEC/EN 60068-2-27, Fa test Resistance to electrostatic discharge Immunity to ESD IEC/EN 61000-4-2, level 3 Resistance to HF interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3, Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Conducted and radiated emissions Class B (*) in accordance with EN 55022/11 group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in metallic cabinet) Operating temperature -20 →+55 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-2-2 Storage temperature -40 →+70 °C in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-2-2 Relative humidity 95 % max. (no condensation or dripping water) in accordance with IEC/EN 60068-2-30 Mounting On symmetrical DIN profile, 35 x 7.5 mm and 35 mm x 15 or panel (2 x 4 mm Ø) Screw terminals connection capacity Flexible wire with ferrule = 2 1 conductor : 0.25 to 2.5 mm (AWG 24...AWG 14) 2 2 conductors 0.25 to 0.75 mm (AWG 24...AWG 18) Semi-rigid wire = 2 1 conductor : 0.2 to 2.5 mm (AWG 25...AWG 14) Rigid wire = 2 1 conductor : 0.2 to 2.5 mm (AWG 25...AWG 14) 2 2 conductors 0.2 to 1.5 mm (AWG 25...AWG 16) Tightening torque = 0.5 N.m (4.5 lb-in) (tighten using screwdriver diam. 3.5 mm) Processing characteristics of CB, CD, XD & XB product types LCD display CD, XD : Display with 4 lines of 18 characters Programming method Ladder or function blocks/SFC (Grafcet) Program size Ladder : 120 lines Function blocks : CB, CD : typically 350 blocks XB, XD : typically 700 blocks Program memory Flash EEPROM Removable memory EEPROM Data memory 368 bits/200 words Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected 05/06/2012 www.crouzet.com Back-up time in the event of power failure Program and settings in the controller : 10 years Program and settings in the plug-in memory : 10 years Data memory : 10 years Cycle time Ladder : typically 20 ms Function blocks : 6 →90 ms Response time Input acquisition time + 1 to 2 cycle times Clock data retention 10 years (lithium battery) at 25 °C Clock drift Drift < 12 min/year (at 25 °C) 6 s/month (at 25 °C with user-definable correction of drift) Timer block accuracy 1 % ± 2 cycle times Start up time on power up < 1,2 s Characteristics of products with AC power supplied Supply Nominal voltage 24 V AC 100 →240 V AC Operating limits -15 % / +20 % -15 % / +10 % or 20.4 VAC→28.8 VAC or 85 VAC→264 VAC Supply frequency range 50/60 Hz (+4 % / -6 %) 50/60 Hz (+4 % / -6 %) or 47 →53 Hz/57 < 63 Hz or 47→53 Hz/57 < 63 Hz Immunity from micro power cuts 10 ms (repetition 20 times) 10 ms (repetition 20 times) Max. absorbed power CB12-CD12-XD10-XB10 : 4 VA CB12-CD12-XD10-XB10 : 7 VA CB20-CD20 : 6 VA CB20-CD20 : 11 VA XD10 with extension - XD26-XB26 : 7.5 VA XD10-XB10 with extension-XD26-XB26 : 12 VA XD26-XB26 with extension : 10 VA XD26-XB26 with extension : 17 VA Isolation voltage 1780 V AC 1780 V AC Inputs Input voltage 24 V AC (-15 % / +20 %) 100 →240 V AC (-15 % / +10 %) Input current 4,4 mA @ 20,4 V AC 0,24 mA @ 85 V AC 5,2 mA @ 24,0 V AC 0,75 mA @ 264 V AC 6,3 mA @ 28,8 V AC Input impedance 4.6 kΩ 350 kΩ Logic 1 voltage threshold ≥ 14 V AC ≥ 79 V AC Making current at logic state 1 >2 mA >0.17 mA Logic 0 voltage threshold ≤ 5 V AC ≤ 20 V AC (≤ 28 V AC : XE10, XR06, XR10, XR14) Release current at logic state 0 <0.5 mA <0.5 mA Response time with LADDER programming 50 ms 50 ms State 0 →1 (50/60 Hz) State 0 < 1 (50/60 Hz) Response time with function blocks programming Configurable in increments of 10 ms Configurable in increments of 10 ms 50 ms min. up to 255 ms 50 ms min. up to 255 ms State 0 →1 (50/60 Hz) State 0 →1 (50/60 Hz) Maximum counting frequency In accordance with cycle time (Tc) and input response time (Tr)  : In accordance with cycle time (Tc) and input response time (Tr)  : 1/ ( (2 x Tc) + Tr) 1/ ( (2 x Tc) + Tr) Sensor type Contact or 3-wire PNP Contact or 3-wire PNP Input type Resistive Resistive Isolation between power supply and inputs None None Isolation between inputs None None Protection against polarity inversions Yes Yes Status indicator On LCD screen for CD and XD On LCD screen for CD and XD Characteristics of relay outputs common to the entire range Max. breaking voltage 5 →30 V DC 24 →250 V AC Breaking current CB-CD-XB10-XD10-XR06-XR10 : 8 A XD26-XB26 : 8 x 8 A relays, 2 x 5 A relays XE10 : 4 x 5 A relays XR14 : 4 x 8 A relays, 2 x 5 A relays Electrical durability for 500 000 operating cycles Usage category DC-12 : 24 V, 1.5 A Usage category DC-13 : 24 V (L/R = 10 ms), 0.6 A Usage category AC-12 : 230 V, 1.5 A Usage category AC-15 : 230 V, 0.9 A Max. Output Common Current 12A for O8,O9,OA Minimum switching capacity 10 mA (at minimum voltage of 12 V) Minimum load 12 V, 10 mA Maximum rate Off load : 10 Hz At operating current : 0.1 Hz Mechanical life 10,000,000 operations (cycles) Voltage for withstanding shocks In accordance with IEC/EN 60947-1 and IEC/EN 60664-1 : 4 kV Response time Make 10 ms Release 5 ms Built-in protections Against short-circuits : None Against overvoltages and overloads : None Status indicator On LCD screen for CD and XD Characteristics of product with DC power supplied Supply Nominal voltage 12 V DC 24 V DC Operating limits -13 % / +20 % -20 % / +25 % or 10.4 V DC < 14.4 V DC (including ripple) or 19.2 V DC < 30 V DC (including ripple) Immunity from micro power cuts ≤ 1 ms (repetition 20 times) ≤ 1 ms (repetition 20 times) Max. absorbed power CB12 with solid state outputs : 1.5 W CB12-CD12-CD20 with solid state outputs - XD10-XB10 with solid state outputs : 3 W CD12 : 1.5 W XD10-XB10 with relay outputs : 4 W CD20 : 2.5 W XD26-XB26 with solid state outputs : 5 W XD26-XB26 : 3 W CB20-CD20 with relay outputs-XD26 with relay outputs : 6 W Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected 05/06/2012 www.crouzet.com XD26-XB26 with extension : 5 W XD10-XB10 with extension : 8 W XD26 with solid state outputs : 2.5 W XD26-XB26 with extension : 10 W Protection against polarity inversions Yes Yes Digital inputs (I1 to IA and IH to IY) Input voltage 12 V DC (-13 % / +20 %) 24 V DC (-20 % / +25 %) Input current 3,9 mA @ 10,44 V DC 2,6 mA @ 19,2 V DC 4,4 mA @ 12,0 V DC 3,2 mA @ 24 V DC 5,3 mA @ 14,4 VDC 4,0 mA @ 30,0 VDC Input impedance 2.7 kΩ 7.4 kΩ Logic 1 voltage threshold ≥ 7 V DC ≥ 15 V DC Making current at logic state 1 ≥2 mA ≥2.2 mA Logic 0 voltage threshold ≤ 3 V DC ≤ 5 V DC Release current at logic state 0 <0.9 mA <0.75 mA Response time 1 →2 cycle times + 6 ms 1 →2 cycle times + 6 ms Maximum counting frequency I1 & I2 : Ladder (1 k Hz) & FBD (Up to 6 k Hz) I1 & I2 : Ladder (1 k Hz) & FBD (Up to 6 k Hz) I3 to IA & IH to IY : in accordance with cycle time (Tc) and input I3 to IA & IH to IY : in accordance with cycle time (Tc) and input response time (Tr)  : 1/ ( (2 x Tc) + Tr) response time (Tr)  : 1/ ( (2 x Tc) + Tr) Sensor type Contact or 3-wire PNP Contact or 3-wire PNP Conforming to IEC/EN 61131-2 Type 1 Type 1 Input type Resistive Resistive Isolation between power supply and inputs None None Isolation between inputs None None Protection against polarity inversions Yes Yes Status indicator On LCD screen for CD and XD On LCD screen for CD and XD Analogue or digital inputs (IB to IG) CB12-CD12-XD10-XB10 4 inputs IB →IE 4 inputs IB →IE CB20-CD20-XB26-XD26 6 inputs IB →IG 6 inputs IB →IG Inputs used as analogue inputs Measurement range (0 →10 V) or (0 →V power supply) (0 →10 V) or (0 →V power supply) Input impedance 14 kΩ 12 kΩ Input voltage 14.4 V DC max 30 V DC max Value of LSB 14 mV 29 mV Input type Common mode Common mode Resolution 10 bit at maximum input voltage 10 bit at maximum input voltage Conversion time Controller cycle time Controller cycle time Accuracy at 25 °C ± 5 % ± 5 % Accuracy at 55 °C ± 6.2 % ± 6.2 % Repeat accuracy at 55 °C ± 2 % ± 2 % Isolation between analogue channel and power supply None None Cable length 10 m maximum, with shielded cable (sensor not isolated) 10 m maximum, with shielded cable (sensor not isolated) Protection against polarity inversions Yes Yes Potentiometer control 2.2 kΩ/0.5 W (recommended) 2.2 kΩ/0.5 W (recommended) 10 kΩ max. 10 kΩ max. Inputs used as digital inputs Input voltage 12 V DC (-13 % / +20 %) 24 V DC (-20 % / +25 %) Input current 0,7 mA @ 10,44 VDC 1,6 mA @ 19,2 VDC 0,9 mA @ 12,0 VDC 2,0 mA @ 24,0 V DC 1,0 mA @ 14,4VDC 2,5 mA @ 30,0 VDC Input impedance 14 kΩ 12 kΩ Logic 1 voltage threshold ≥ 7 V DC ≥ 15 VDC Making current at logic state 1 ≥0.5 mA ≥1.2 mA Logic 0 voltage threshold ≤ 3 V DC ≤ 5 V DC Release current at logic state 0 ≤0.2 mA ≤0.5 mA Response time 1 →2 cycle times 1 →2 cycle times Maximum counting frequency In accordance with cycle time (Tc) and input response time (Tr)  : In accordance with cycle time (Tc) and input response time (Tr)  : 1/ ( (2 x Tc) + Tr) 1/ ( (2 x Tc) + Tr) Sensor type Contact or 3-wire PNP Contact or 3-wire PNP Conforming to IEC/EN 61131-2 Type 1 Type 1 Input type Resistive Resistive Isolation between power supply and inputs None None Isolation between inputs None None Protection against polarity inversions Yes Yes Status indicator On LCD screen for CD and XD On LCD screen for CD and XD Characteristics of relay outputs common to the entire range Max. breaking voltage 5 →30 V DC 24 →250 V AC Max. Output Common Current 12A (10A UL) for O8,O9,OA Breaking current CB-CD-XD10-XB10-XR06-XR10 : 8 A XD26-XB26 : 8 x 8 A relays, 2 x 5 A relays XE10 : 4 x 5 A relays XR14 : 4 x 8 A relays, 2 x 5 A relays Electrical durability for 500 000 operating cycles Usage category DC-12 : 24 V, 1.5 A Usage category DC-13 : 24 V (L/R = 10 ms), 0.6 A Usage category AC-12 : 230 V, 1.5 A Usage category AC-15 : 230 V, 0.9 A Minimum switching capacity 10 mA (at minimum voltage of 12 V) Minimum load 12 V, 10 mA Maximum rate Off load : 10 Hz At operating current : 0.1 Hz Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected 05/06/2012 www.crouzet.com Mechanical life 10,000,000 operations (cycles) Voltage for withstanding shocks In accordance with IEC/EN 60947-1 and IEC/EN 60664-1 : 4 kV Response time Make 10 ms Release 5 ms Built-in protections Against short-circuits : None Against overvoltages and overloads : None Status indicator On LCD screen for CD and XD Digital / PWM solid state output PWM solid state output* CB12 : O4 CD12-XD10-XB10 : O4 XD26 : O4 →O7 CD20-XD26-XB26 : O4 →O7 * Only available with "FBD" programming language * Only available with "FBD" programming language Breaking voltage 10.4 →30 VDC 19.2 →30 VDC Nominal voltage 12-24 V DC 24 V DC Nominal current 0.5 A 0.5 A Max. breaking current 0,625 A 0,625 A Voltage drop ≤ 2 V for I = 0.5 A (at state 1) ≤ 2 V for I = 0.5 A (at state 1) Response time Make ≤ 1 ms Make ≤ 1 ms Release ≤ 1 ms Release ≤ 1 ms Built-in protections Against overloads and short-circuits : Yes Against overloads and short-circuits : Yes Against overvoltages (*)  : Yes Against overvoltages (*)  : Yes Against inversions of power supply : Yes Against inversions of power supply : Yes (*) In the absence of a volt-free contact between the output of the (*) In the absence of a volt-free contact between the output of the logic controller and the load logic controller and the load Min. load 1 mA 1 mA Maximum incandescent load 0,2 A / 12 V DC 0,1 A / 24 V DC 0,1 A / 24 V DC Galvanic isolation No No PWM frequency 14.11 Hz 14.11 Hz 56.45 Hz 56.45 Hz 112.90 Hz 112.90 Hz 225.80 Hz 225.80 Hz 451.59 Hz 451.59 Hz 1806.37 Hz 1806.37 Hz PWM cyclic ratio 0 →100 % (256 steps for CD, XD and 1024 for XA) 0 →100 % (256 steps for CD, XD and 1024 for XA) PWM accuracy at 120 Hz < 5 % (20 % →80 %) load at 10 mA < 5 % (20 % →80 %) load at 10 mA PWM accuracy at 500 Hz < 10 % (20 % →80 %) load at 10 mA < 10 % (20 % →80 %) load at 10 mA Status indicator On LCD screen for CD and XD On LCD screen for CD and XD Type Description Code M3 SOFT Multilingual programming software containing specific library functions (CD-ROM) 88970111 PA EEPROM memory cartridge 88970108 PA 3 m serial link cable : PC →Millenium 3 88970102 PA USB cable 3 m : PC →Millenium 3 88970109 PA Millenium 3 interface →Bluetooth (class A 10 m) 88970104 Comments st * to be marketed 1 quarter 2006 Dimension Diagram : XD26 Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected

Frequently asked questions

What makes Elite.Parts unique?

chervon down
At GID Industrial (Elite.Parts' parent company), we specialize in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

What kind of warranty will the 88970162 have?

chervon down
Warranties differ by part and by which suppliers we use to procure it for you. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carriers does Elite.Parts work with?

chervon down
Elite.Parts can ship via FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Will Elite.Parts sell to me even though I live outside the USA?

chervon down
Absolutely! We are happy to serve customers regardless of location. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

I have a preferred payment method. Will Elite.Parts accept it?

chervon down
All major credit cards are accepted: Visa, MasterCard, Discover, and American Express. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

Crouzet 83131701 Relays - Snap Switch

product

Crouzet 831613C3/DB Miniature Switch - 10.1A Switch

product

Crouzet 88857005 Timer Module - 8 A; 24 VAC/VDC/110 VAC to 240 VAC; Electronic; Selectable; LCD;...

product

Crouzet 88857800 Timer - 8 A (Max.); 24/48 VAC; Solid State; SPDT; 8 VA @ 115 VAC/0.5 W @ 12 VD...

product

Crouzet 88886016 Timer. 5 A; 12 to 240 VDC, 24 to 240 VAC; 0.02 Sec. to 300 hr; Analog; LED

product

Crouzet GNR45BCZ Relay Solid State, Din Rail Mount, 45mm, 90-140Vac, 45A, 660Vac