COSEL P300E
Features
- Built-in Inrush Current Protection
- Built-in Over Current Protection
- Built-in Over Voltage Protection
- RoHS Compliant
- Small and compact size
- World wide input voltage
Datasheet
Extracted Text
Home > Product Details P300E Features World wide input voltage Small and compact size Built-in Inrush Current Protection Built-in Over Current Protection Built-in Over Voltage Protection RoHS Compliant Safety Agency Approvals Complies with DEN-AN UL1950 CSA 22.2 No.234 EN60950, VDE0160 (without PT1500U) EMI Compliance P15E, 30E, 50E : Complies with FCC-B P100E, 150E, 300E, 600E, 1500E, PT1500U : Complies with FCC-A 3 year warranty(refer to Instruction Manual) Input Output DC Voltage Wattage Output Model [V] [W] [V/A] 5V P300E-5 AC 85 - 264 300 60A 12V P300E-12 AC 85 - 264 324 27A 15V P300E-15 AC 85 - 264 330 22A 18V P300E-18 AC 85 - 264 306 17A 24V P300E-24 AC 85 - 264 336 14A 30V P300E-30 AC 85 - 264 300 10A 48V P300E-48 AC 85 - 264 312 6.5A Ordering information Unit type P 300 E -5 -O P300E P 12345 1Series name R 2Output wattage 3UL recognized,TuV approved, CSA certified:E 4Output voltage 5Optional C :with Coating G :Low leakage current R :Positive logic control RoHS : Please consult us for details MODEL P300E-5 P300E-12 P300E-15 P300E-18 P300E-24 P300E-30 P300E-48 MAX OUTPUT WATTAGE[W] 300 324 330 306 336 300 312 DC OUTPUT 5V 60A 12V 27A 15V 22A 18V 17A 24V 14A 30V 10A 48V 6.5A SPECIFICATIONS MODEL P300E-5 P300E-12 P300E-15 P300E-18 P300E-24 P300E-30 P300E-48 ( ) VOLTAGE[V] AC85 - 132 / 170 - 264 1 Auto-selectable f 1 ( ) ACIN 100V* 5.5typ Io=100% CURRENT[A] *1 ( ) ACIN 200V 3.5typ Io=100% INPUT FREQUENCY[Hz] 47-63 EFFICIENCY[%] 74typ 78typ 81typ 81typ 83typ 78typ 79typ ( )( ) ACIN 100V 25/40typ Io=100% Primary inrush current /Secondary inrush current INRUSH CURRENT[A] ( )( ) ACIN 200V 50/40typ Io=100% Primary inrush current /Secondary inrush current VOLTAGE[V] 5 121518243048 CURRENT[A] 60 27 22 17 14 10 6.5 MAX OUTPUT WATTAGE[W] 300 324 330 306 336 300 312 LINE REGULATION[mV] 20max 48max 60max 72max 96max 120max 192max LOAD REGULATION[mV] 40max 100max 120max 144max 150max 180max 300max *2 OUTPUT RIPPLE[mVp-p] 80max 120max 120max 120max 120max 120max 150max 2 RIPPLE NOISE[mVp-p] * 120max 150max 150max 150max 150max 200max 400max TEMPERATURE REGULATION[mV] 0to+50 50max 120max 150max 180max 240max 300max 480max C OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 10% t START-UP TIME[ms] 300max (ACIN 85/170V, Io=100%) ( , ) ( , ) HOLD-UP TIME[ms] 20typ ACIN 85/170V Io=100% 40typ ACIN 100/200V Io=100% OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically PROTECTION CIRCUIT OVERVOLTAGE PROTECTION Works at 115 - 140% of rating , , , ( ) INPUT-OUTPUT RC AC3 000V 1minute Cutoff current = 10mA DC500V 50M min At Room Temperature - W , , , ( ) INPUT-FG AC2 000V 1minute Cutoff current = 10mA DC500V 50M min At Room Temperature W ISOLATION OUTPUT RC-FG AC500V 1minute, Cutoff current = 100mA, DC500V 50M min (At Room Temperature) - W , , ( ) OUTPUT-RC AC100V 1minute Cutoff current = 100mA DC100V 50M min At Room Temperature W , , ( )( ), , ( , ) OPERATING TEMP. HUMID.AND ALTITUDE -10 to +60 20 - 95%RH Non condensing Refer to DERATING CURVE 3 000m 10 000feet max C STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75 , 20 - 95%RH (Non condensing), 9,000m (30,000feet) max C ENVIRONMENT 2 , ( ), , , VIBRATION 10 - 55Hz 19.6m/s 2G 3minutes period 30minutes each along X Y and Z axis 2 ( ), , , IMPACT 196.1m/s 20G 11ms once each X Y and Z axis SAFETY AND AGENCY APPROVALS UL60950-1, EN60950-1, EN50178, CSA C22.2 No.234 Complies with DEN-AN and IEC60950-1 NOISE REGULATIONS CONDUCTED NOISE Complies with FCC-A *1 The input current of the agency approved unit is indicated as 6.5A (ACIN 100V) or 3.6A (ACIN 200V). *2 According to 15MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101). A-80 P300E P External view ¶Weight : 2.5kg or less ¶Tolerance : t1 ¶Dimensions in mm. . . ¶Mounting torque:1.5N m(16kgf cm)max Performance data ¡Automatic Input Voltage Selector Requires no manual adjusutment(wire or Short-pieces) . P300 unit detects input voltage then select circuit to match applied input voltage. ¡Automatic Current sharing ¡ Output voltage is controlled by a potentiometer in master unit. Turn slave unit's potentiometer clock wise all the way to the end. ¡ Maximun output current can be determined by using the following formula: Total output current = 0.9 †(Rated current per unit)† Number of units paralleled ¡ Five units maximum for the parallel operation. ¡DERATING CURVE The shadow indicates the region where different * specifications for ripple noise should be used. A-81
Frequently asked questions
What makes Elite.Parts unique?

What kind of warranty will the P300E have?

Which carriers does Elite.Parts work with?

Will Elite.Parts sell to me even though I live outside the USA?

I have a preferred payment method. Will Elite.Parts accept it?

What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods