COSEL AD240-24
Features
- Fully Regulated, Fully Isolated Input/Output
- High Quality — Field Failure Rate Less Than 0.012%
- In-rush Current, Over-Voltage and Over-Current Protection Circuitry
- Output Voltage: 24 VDC
- User Selectable Input:AC 85 ~ 132/170 ~ 264
Datasheet
Extracted Text
Home > Product Details AD240 Features User-selectable input voltage(AC85 - 132V/AC170 - 264V) (AD240, 480) Built-in Inrush Current Protection Small size and light Parallel and Master-Slave operation Built-in Over Current Protection Built-in Over Voltage Protection RoHS Compliant 2 year warranty(refer to Instruction Manual) Input Output DC Voltage Wattage Output Model [V] [W] [V/A] 24V AD240-24 AC 85 - 264 240 10A 30V AD240-30 AC 85 - 264 240 8A Ordering information Unit type AD 240 -24 -O AD240 1234 1Series name 2Output wattage 3Output voltage 4Optional AD C :with Coating G :Low leakage current P :Parallel operation R :with Remote ON/OFF MODEL AD240-24 AD240-30 MAX OUTPUT WATTAGE[W] 240 240 DC OUTPUT 24V 10A 30V 8A SPECIFICATIONS MODEL AD240-24 AD240-30 ( ) VOLTAGE[V] AC85 - 132 / 170 - 264 1 User-selectable f FREQUENCY[Hz] 47 - 440 EFFICIENCY[%] 85typ 85typ INPUT ( ) ACIN 100V 15max Io=100% INRUSH CURRENT[A] ACIN 200V 30max (Io=100%) ( , ) LEAKAGE CURRENT[mA] 1.0max 60Hz According to DEN-AN VOLTAGE[V] 24 30 CURRENT[A] 10 8 LINE REGULATION[mV] 300max 260max LOAD REGULATION[mV] 300max 420max 1 RIPPLE[mVp-p] 0to+45 * 240max 240max C *1 OUTPUT RIPPLE NOISE[mVp-p] 0to+45 480max 480max C TEMPERATURE REGULATION[mV] 0to+45 500max 600max C 2 DRIFT[mV] * 500max 120max OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 21.6 - 26.4 28.5 - 33.0 ( , ) START-UP TIME[ms] 500max ACIN 100/200V Io=100% HOLD-UP TIME[ms] 15typ (ACIN 100/200V, Io=100%) PROTECTION OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically CIRCUIT , , , ( ) INPUT-OUTPUT AC1 500V 1minute Cutoff current = 10mA DC500V 100M min At Room Temperature W ISOLATION INPUT-FG AC1,500V 1minute, Cutoff current = 10mA, DC500V 100M min (At Room Temperature) W , , ( ) OUTPUT-FG AC500V 1minute Cutoff current = 50mA DC500V 100M min At Room Temperature W , , ( )( ), , ( , ) OPERATING TEMP. HUMID.AND ALTITUDE 0to+60 20 - 90%RH Non condensing Refer to DERATING CURVE 3 000m 10 000feet max C STORAGE TEMP.,HUMID.AND ALTITUDE -25 to +80 , 10 - 95%RH (Non condensing), 9,000m (30,000feet) max C ENVIRONMENT 2 , ( ), , , VIBRATION 10 - 55Hz 19.6m/s 2G 3minutes period 30minutes each along X Y and Z axis 2 ( ), , , IMPACT 98.0m/s 10G 20ms once each X Y and Z axis CASE SIZE/WEIGHT 75 99 220mm (W H D) /1.8kg max X X X X OTHERS COOLING METHOD Convection *1 Measured by 15MHz oscilloscope. *2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. A-136 AD240 External view max 75 20 200 +0.5 +0.5 12.5 12.5 50 50 - - Voltage Adjust (23) AD LM AD240 +V -V FG VS1 VS2 AC1 100/200 AC2 4-M3 M4 4-M3 Mounting Hole Mounting Hole ¶2 3-M3 ¶1 Mounting Hole ¶2 Safety Cover + 0.5 - +0.5 20 175 - ¶Mounting torque ¶1: 0.6N•m(6.3kgf•cm)max ¶Weight : 1.8kg or less ¶2: 0.4N•m(5.0kgf•cm)max ¶Tolerance : t1 ¶Dimensions in mm. Performance data STATIC CHARACTERISTICS RISE TIME & FALL TIME ¡ ¡ 24 Output Voltage 22 900 20 700 18 Io=100% Io=50% 16 AC100V Io=100% 14 500 12 DC Output 10 300 AC Input 8 ACIN 100V Ripple 100 0 40 50 60 70 80 90 100 110 120 130 140 50ms/DIV 60Hz INPUT VOLTAGE V ( AC 100V ) ¡OVERCURRENT CHARACTERISTICS ¡DERATING CURVE 26 24 22 20 qConvection 3 wForced Air(0.5m /min) 18 16 14 12 0 24 6 8 10 12 14 OUTPUT CURRENT A A-137 OUTPUT VOLTAGE OUTPUT VOLTAGE V V (83.5) +0.5 89 5 - 99 (17.5)9.5 8.1 (27) RIPPLE mVp-p +0.5 65 +0.5 - 89 5 -
Frequently asked questions
What makes Elite.Parts unique?

What kind of warranty will the AD240-24 have?

Which carriers does Elite.Parts work with?

Will Elite.Parts sell to me even though I live outside the USA?

I have a preferred payment method. Will Elite.Parts accept it?

What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods