CORCOM F-3374
Datasheet
Extracted Text
1308230 - CORCOM, Englisch 07.08.2003 12:56 Uhr Seite 1 Catalog 1308230 Rev. 07-03 GLOBAL INDUSTRIAL AND COMMERCIAL RFI Power Line Filters 1308230 - CORCOM, Englisch 07.08.2003 12:56 Uhr Seite 2 CORCOM Catalog 1308230 Rev. 07-03 RFI Power Line Filters Table of Contents Content PageContent Page CORCOM Filters for RFI Solutions Summary . . . . . . . . . . . . . . . . . . . . . . . . . 1–3 VS-, VV-, VW-Series . . . . . . . . . . . . . . . . . 54–55 Introduction . . . . . . . . . . . . . . . . . . . . . . . 4–8 MV-Series . . . . . . . . . . . . . . . . . . . . . . . . 54–55 RFI Power Line Filters P-Series . . . . . . . . . . . . . . . . . . . . . . . . . . 9–12 SK-Series . . . . . . . . . . . . . . . . . . . . . . . . . 56–57 Power Entry Products M-Series . . . . . . . . . . . . . . . . . . . . . . . . . 13–18 T-Series . . . . . . . . . . . . . . . . . . . . . . . . . . 58–59 High Power Filters EDL-, EHL-Series . . . . . . . . . . . . . . . . . . . 19–21 EP-/VP-Series . . . . . . . . . . . . . . . . . . . . . . 60PCB Filters LC Filtered Jacks F-3558 . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 X-, Z-Series . . . . . . . . . . . . . . . . . . . . . . . 61 Facility Filters LA-Series . . . . . . . . . . . . . . . . . . . . . . . . . 23–24 Q-Series . . . . . . . . . . . . . . . . . . . . . . . . . . 62–63 Military Filters J-Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 FC-Series . . . . . . . . . . . . . . . . . . . . . . . . . 64–65 C-Series . . . . . . . . . . . . . . . . . . . . . . . . . . 26–27 IK-Series . . . . . . . . . . . . . . . . . . . . . . . . . 66–67 EGG-Series . . . . . . . . . . . . . . . . . . . . . . . . 28–29 A-Series . . . . . . . . . . . . . . . . . . . . . . . . . . 68–69 EBF-Series . . . . . . . . . . . . . . . . . . . . . . . . 30 AYC-Series . . . . . . . . . . . . . . . . . . . . . . . . 70–71 CORCOM filters comply with the requirements of the low EEA-, EEB-Series . . . . . . . . . . . . . . . . . . . 31–33 ADT-Series . . . . . . . . . . . . . . . . . . . . . . . . 72–73 voltage directive and can be EF-Series . . . . . . . . . . . . . . . . . . . . . . . . . 34–35 AYA-Series . . . . . . . . . . . . . . . . . . . . . . . . 74–75 CE marked. ED-Series . . . . . . . . . . . . . . . . . . . . . . . . . 36–37 AYO-Series . . . . . . . . . . . . . . . . . . . . . . . . 76 EC-Series . . . . . . . . . . . . . . . . . . . . . . . . . 38–39 F-Series . . . . . . . . . . . . . . . . . . . . . . . . . . 77–79 Corcom products are manufac- EH-Series . . . . . . . . . . . . . . . . . . . . . . . . . 40–41 FCD-Series . . . . . . . . . . . . . . . . . . . . . . . . 80–82 tured in several locations, stocked and distributed through a world- XP-, YP-, ZP-Series . . . . . . . . . . . . . . . . . 42–43 FCD10BS-Series . . . . . . . . . . . . . . . . . . . . 83 wide network of Tyco Electronics F-3443 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 CFN-Series . . . . . . . . . . . . . . . . . . . . . . . . 84 Sales Offices and stocking distri- butors. EBP-, EDP-, EOP-Series . . . . . . . . . . . . . . 44 BCD-Series . . . . . . . . . . . . . . . . . . . . . . . . 85–87 G/N-Series . . . . . . . . . . . . . . . . . . . . . . . . 45 AQ-Series . . . . . . . . . . . . . . . . . . . . . . . . . 88–89 B-Series . . . . . . . . . . . . . . . . . . . . . . . . . . 46–47 SignalSentry . . . . . . . . . . . . . . . . . . . . . . . 90–91 K-Series . . . . . . . . . . . . . . . . . . . . . . . . . . 48–49 Cross Reference List . . . . . . . . . . . . . . . . . 92–95 R-Series . . . . . . . . . . . . . . . . . . . . . . . . . . 50–51 Further Products . . . . . . . . . . . . . . . . . . . . 96 DK-Series . . . . . . . . . . . . . . . . . . . . . . . . . 52–53 Filter Selection Chart . . . . . . . . . . . . . . . . . 97 Series in Alphabetical Order Series PageSeries PageSeries Page A . . . . . . . . . . . . . . . . . . . . 68 EEA . . . . . . . . . . . . . . . . . . 31 LA . . . . . . . . . . . . . . . . . . . 23 ADT . . . . . . . . . . . . . . . . . . 72 EEB . . . . . . . . . . . . . . . . . . 31 M . . . . . . . . . . . . . . . . . . . . 13 AQ . . . . . . . . . . . . . . . . . . . 88 EF . . . . . . . . . . . . . . . . . . . 34 MV . . . . . . . . . . . . . . . . . . . 54 AYA . . . . . . . . . . . . . . . . . . 74 EGG . . . . . . . . . . . . . . . . . . 28 N . . . . . . . . . . . . . . . . . . . . 45 AYC . . . . . . . . . . . . . . . . . . 70 EH . . . . . . . . . . . . . . . . . . . 40 P . . . . . . . . . . . . . . . . . . . . 9 AYO . . . . . . . . . . . . . . . . . . 76 EHL . . . . . . . . . . . . . . . . . . 19 Q . . . . . . . . . . . . . . . . . . . . 62 B . . . . . . . . . . . . . . . . . . . . 46 EHT . . . . . . . . . . . . . . . . . . 58 R . . . . . . . . . . . . . . . . . . . . 50 BCD . . . . . . . . . . . . . . . . . . 85 EOP . . . . . . . . . . . . . . . . . . 44 SignalSentry . . . . . . . . . . . . 90 C . . . . . . . . . . . . . . . . . . . . 26 EP/VP . . . . . . . . . . . . . . . . . 60 SK . . . . . . . . . . . . . . . . . . . 56 CFN . . . . . . . . . . . . . . . . . . 84 F . . . . . . . . . . . . . . . . . . . . 77 T . . . . . . . . . . . . . . . . . . . . 58 DK . . . . . . . . . . . . . . . . . . . 52 FC . . . . . . . . . . . . . . . . . . . 64 VS . . . . . . . . . . . . . . . . . . . 54 EAH . . . . . . . . . . . . . . . . . . 31 FCD . . . . . . . . . . . . . . . . . . 80 VV . . . . . . . . . . . . . . . . . . . 54 All specifications subject to change. EBF . . . . . . . . . . . . . . . . . . 30 FCD10BS . . . . . . . . . . . . . . 83 VW . . . . . . . . . . . . . . . . . . . 54 Consult Tyco Electronics for latest EBH . . . . . . . . . . . . . . . . . . 31 F-3443 . . . . . . . . . . . . . . . . 43 X . . . . . . . . . . . . . . . . . . . . 61 design specifications. This also applies to contents and EBP . . . . . . . . . . . . . . . . . . 44 F-3558 . . . . . . . . . . . . . . . . 22 XP . . . . . . . . . . . . . . . . . . . 42 revisions of technical standards and EC . . . . . . . . . . . . . . . . . . . 38 G/N . . . . . . . . . . . . . . . . . . 45 YP . . . . . . . . . . . . . . . . . . . 42 guidelines referred to in this catalog. ED . . . . . . . . . . . . . . . . . . . 36 IK . . . . . . . . . . . . . . . . . . . . 66 Z . . . . . . . . . . . . . . . . . . . . 61 All dimensions in millimeters. EDL . . . . . . . . . . . . . . . . . . 19 J . . . . . . . . . . . . . . . . . . . . 25 ZP . . . . . . . . . . . . . . . . . . . 42 AMP, CORCOM and TYCO are registered trademarks. EDP . . . . . . . . . . . . . . . . . . 44 K . . . . . . . . . . . . . . . . . . . . 48 Summary General Purpose Power Entry Module PCB Filters with/without Filters XP-, YP-, ZP-Series M-Series F-3443 Page 42 Page 13 PCB Filters Chassis-mount for various Filters Requirements EBP-, EDP-, EOP-Series X-, Z-Serie Page 44 Page 61 Power Entry Module Universal with/without Filters and Chassis-mount variable Construction Filters P-Series B-Series Page 9 Page 46 Power Entry Module Chassis/Back Panel Filters Mount Filters with/without IEC Connector EDL-, EHL-Series, F-3558 R-Series Page 19 Page 50 Power Entry Modules Universal Chassis/ with/without Filters Back Panel Mount Filters with/without IEC Connector J-Series K-Series Page 25 Page 48 IEC Connector Universal Chassis/ Filters Back Panel Mount Filters with IEC EEA-, EEB-Series Connector DK-Series Page 31 Page 52 Faston-, Solder Lugs or Wire Terminals 3-Phase Filters IEC Connector Filters AYO-Series EF-Series, EH-Series Page 34,40 Page 76 Faston-, Solder Lugs or Wire Terminals All specifications subject to change. Consult Tyco Electronics for latest design specifications. 1 For Wide Performance Range Power Entry Module IEC Connector with high Filters performance Filter EC-Series, ED-Series LA-Series Page 23 Page 38 / 36 Faston- or Wire Terminals IEC Connector Chassis-mount Filters Filters with Fuses EGG-Series G/N-Series Page 28 Faston- or Wire Terminals Page 45 IEC Connector Chassis-mount Filters Filters VS-, VV-, VW-Series EBF-Series NEW: MV-Series for medical applications up to 20A/250VAC Page 30 Faston- or Wire Terminals Page 54 IEC Connector Chassis/Back Panel Filters Mount Filters with Fuses with/without IEC Connector EHG-Series SK-Series Page 56 Page 28 For medical applications 2-Phase Filters 3-Phase Filters (With neutral) IK-Series AYA6-Series Page 66 Page 74 IEC Connector Filters High Current with double Pole Switch Filters C-Series CFN-Series NEW Page 26 Page 84 2 All specifications subject to change. Consult Tyco Electronics for latest design specifications. For Superior Performance Chassis-mount Filters 3-Phase Filters with Screw Type Terminals A-Series ADT-Series FC10-Series Page 64 Page 68, 72 Chassis-mount 3-Phase Filters Filters F-Series T-Series For medical applications Page 77 Page 58 up to 15A / 250VAC Chassis/Back Panel mount 3-Phase Filters Filters with/without with Screw Type IEC Connector Terminals FCD-Series EP-Series Page 80 Page 60 Chassis/Back Panel mount Line Filters Filters with/without for Tempest IEC Connector Applications Q-Series AQ-Series For medical applications Page 88 Page 62 up to 6A / 250VAC 3-Phase plus Neutral Chassis-mount Filters Filters with Screw Terminal Plugs AYC-Series FC10B-, FCD10B-Series Page 70 Page 64, 83 3-Phase Filters 3-Phase Filters BCD-Series FCD10BS-Series Page 85 Page 83 All specifications subject to change. Consult Tyco Electronics for latest design specifications. 3 Introduction 1. General From the propagation of conducted interferences three different modes are being distinguished: Interference suppression filters are being used in the conducted U1 = Symmetrical noise value (differential mode) area of electromagnetic susceptibility to reduce noise U2, U3 = Unsymmetrical noise value potentials (currents, voltages). U4 = Asymmetrical noise value (common mode) Noise potentials may be of natural origin (lightning, electrostatic discharge) as well as of technical origin (transient voltages, Figure 3 switches, semiconductor switches, oscillators, switched po- wer supplies). Both commonly produce - wanted or unwanted P - noise spectra leading to undue influence of neighbouring U U electronical devices or systems. These interferences are 1 4 being distinguished into wide band and narrow band values. Device N Typical wide band interference values are • Transient noise voltages on the power lines U2 U 3 • Mechanical switches • Thyristor switches • Commutator motors B. 3. Figure 1 Continuous noise spectrum db (µV) 2. Purpose of Filtering 100 Filters preferably show bilateral results. Figure 4 visualizes the function of interference suppression filters: Example: 66 Figure 4 N Conductive Power line noise Noise source Noise drain MHz Way of influence 0,15 30 Device 1 Device 2 Filter Filter 1. Reduction of 2. Reduction of transmission of conducted influence conducted noise of noise value Typical small band interference values are values (Noise immunity) • Supersonic devices • Switched power (RFI suppresion) supplies • Transmitters • HF generators The purpose of filters is therefore to reduce the emission of Figure 2 Discrete noise spectrum noise (RFI suppression) and to prevent noise values from being entered into electronic systems (noise immunity). In the FRG db (µV) the area of RFI suppression is governed by law. For the 100 operation of electronic equipment an approval by the German Postal Authorities is mandatory (see item 8 Regulations). Even though noise immunity is not legally governed until end of 1995 it seems obvious that devices unduely influenced by its 54 environment can not be marketed easily (see also item 8 B Regulations). 3. Function of Filters MHz 0,15 30 Suppression filters are usually low pass filters in form of TT- The propagation modes for interference potentials are or T-networks. According to their requirements multistage filter arrangements can be built. The effects of such measures • Radiation (electromagnetic waves in free space) • Conduction (noise voltages/currents on power lines or are steep filter characteristics and high attenuations over a wide frequency range. Filter networks of todays design usually data lines) In order to reduce conducted interferences an interference work on the principles of reflexion. This means that the greater the mismatch of filter impedance to terminating impedance, filter is the primary tool available. The frequency range concerned reaches from several kHz to approximately 30 the more effective the filter is in attenuating interference energies, e.g. low power line impedance should be met by high MHz. Above this value the main means of propagation are radiated phenomena (antenna effect). filter impedance. 4 All specifications subject to change. Consult Tyco Electronics for latest design specifications. Figure 5 Impedance conditions for power line filters Figure 9 P P' Device impedance Power line impedance at high frequencies at high frequencies 501 501 Filter Low Z High Z N N' N = 2 or "L" Low Z Low Z Measurements of attenuation are being performed over a wide frequency range. Figure 10 shows the typical attenuation curves resulting for the Corcom filter type 3EQ3. N = 3 or "T" Figure 10 asym. sym. dB 4. Insertion Loss 90 80 The selection criteria for a filter is its insertion loss. It is defined 70 as the logarithmic ratio of the power delivered into a defined 60 50 output impedance with and without filter. 40 P Ref. 30 A = 10 x log P 20 10 P : Power between energy source and load without filter Ref. 0 0,01 0,1 1 10 30 (Figure 6) Frequency in MHz P: Power between source and load with filter inserted 3EQ (Figure 7) The predictability of the actual performance of insertion loss Figure 6 Measurement of insertion values without filter in a real application is not very accurate. The reason for this is R 1 the measuring method in a closed 50 Ohm system. In reality it is quite doubtful that line impedance as well as device impedance will stay at 50 Ohms over an extended frequency U 0 E R range. Therefore the true performance of a filter can only be 1 measured empiricly within a device or system by the user. For quality assurance however the insertion loss is an important tool. This measurement can certainly be used to prove a product's quality and consistency. Figure 7 Measurement of insertion values with filter 5. Typical Filter Network I I 2 R 1 Figure 11 E F R 2 U 1 C Power line X L Device The insertion loss can also be directly specified as voltage ratio U 0 A = 20 x log ( ) U 1 When measuring attenuation it can usually be distinguished C CY Y between Symmetrical attenuation (differential mode) and Asymmetrical attenuation (common mode). This network is the most frequently used type in real a) Measurement of the asymmetrical component applications. It serves for both asymmetrical as well as (common mode) symmetrical interference suppression. Symmetrical interferences are being suppressed by the capacitor showing Figure 8 P P' the suffix X. If these capacitances are not sufficient, additional Filter inductances (e.g. linear inductors) will be neccessary. N N' Asymmetrical interferences are being reduced by shown 501 501 inductances and the capacitors carrying the suffix Y. The Y- capacitors connected to safety ground are acting as HF- shunts. The value of the capacity is determined by the maximum permissible leakage current of the device. The inductivities shown in the network above are usually current compensated inductances. For operating current these inductivities are of very low values. According to its winding technique the b) Measurement of the symmetrical component (differential magnetic flux in the core is being neutralized, when operating mode) All specifications subject to change. Consult Tyco Electronics for latest design specifications. 5 current is flowing through. In case of asymmetrical interferences The observance of above mentioned safety regulations does however the magnetic fluxes are supporting one another. not free the designer of Electronic equipment from the Therefore the inductances show their full efficiency. responsibility to verify the safety instructions, for which the device must be designed. These regulations have first priority. 6. Capacitors 7.2 Operating Current The ceramic type capacitors used by Corcom offer - besides The permissible nominal current for Corcom filters is specified their very high 18 to 20 years life cycle as compared to a for an ambient temperature of 40°C. Above this temperature normal foil capacitor - a substantially better HF frequency the permissible nominal current will be reduced according to response making it the best choice for use in filter networks. the graph and formula shown in Figure 13 below. The following diagram illustrates the HF response of a foil capacitor as compared with the ceramic capacitor used by Figure 13 Dependency of current I and ambient perm Corcom. Both devices are specified with 5.000 pF at 1 kHz. temperature Figure 12 1,2 P N dB 1 90 85° – µ P =Pn· 80 perm 85° – n 3 70 60 50 Corcom 40 type 0,5 30 Foil type 20 10 0 0,0 20,0 40,0 60,0 Frequency in MHz n = 40°C 80°C85°C Temp.µ 7. General Technical Data Peak current load: 7.1 Safety Regulations The operating current of most devices is not sinusoidal. Often high peak values appear during short periods of current flow. Interference suppression filters are subject to both national as Corcom filters are designed to show no sign of saturation even well as international testing regulations. A summary of the if the current load is 3 to 6 times the nominal value. most important regulations and testing agencies is shown in All inductances mentioned in the catalog are measured at the table below. nominal load. Summary of International Testing Agencies Line Filter Regulations and Specifications Leakage Current Insulation Qualification High Current Approving Equipment Requirement* Resistance Hipot Rating Voltage Overload Organization City Specifications Country Maximum I at (1 minute) Minimum at Pulse Test Name 6 mA V HZ 1 x 10 V Test 1 3,4 United 0.5 250 50 2250 VDC or 6.000 100 — — BEAB London BS6201 Part 3 2 3 Kingdom 0.25/5.0 250 50 1500 VAC (BSI) 4 4.3 x Ur. VDC 4 20 100 — — BS613 1 3,4 Switzerland 0.5 250 50 2250 VDC or 3.000 100 Yes — SEV Zürich IEC939.1988 2 3 0.25/5.0 250 50 1500VAC Par 5.6 7 2000 VAC 4 4.3 x Ur. VDC 1 3 3,4 Sweden 0.5 250 50 1500 VAC 6.000 100 — — SEMKO Stockholm SEN432901 2 0.25/5.0 250 50 3 Canada 5.0 120 60 1000+2Ur. VAC — — — — CSA Rexdale C22.2 No.0 1414 VDC Min. No. 0.4 500+2Ur. VDC No. 14 1,5 3 3,4 Germany 0.75/3.5 250 50 1500 VAC 6.000 100 — 75xI VDE Offenbach EN133200 2 4 0.25/3.5 250 50 4.3 x Ur.VDC rated for EN60950 3 2,000 100 Yes 2.5 cycles 4 1,500 100 Par 5.419 France — — — — — — — — UTE Paris — United 5.0 125 60 1000 VAC or — — — — UL Various UL1283, 544 3 States 1414 VDC UL2601 1000 VAC or 4 1414 VDC 1500 VAC or 8 2121 VDC Ur-Line voltage *applicable throughout Europe (substitude for national norms) 1-Devices of Safety Class 1 4-Conductor-Conductor 7-Between conductor and un-unzeroed (non-metallic) case 2-Devices of Safety Class 2 5-Lower values for mobile devices 8-Conductor-Ground line/Case and condutor-conductor 3-Conductor-Ground line/Case 6-At higher temperatures for units not to be touched by a patient 6 All specifications subject to change. Consult Tyco Electronics for latest design specifications. P . perm Moreover Corcom filters are being tested at 6 times the If not explicitly stated in the various data sheets, the max. nominal current for 8 seconds. permissible operating voltage for filters is 250 VAC, 50/60 Hz. Filters can also be used in DC-networks if above stated 7.3 High Voltage Test operating voltages are not exceeded. 7.6 Climate Class All Safety Class I Corcom filters are being tested with the following parameters (100 % testing): All filters are of Climate Class JPF (Ambient Temperature -10° to +85°C) P, N - Ground = 1800 VAC/2 sec for filter homologation Other values on special request. P - N = 1450 VDC/2 sec 1 minute permitted 7.4 Leakage Current 8. Standards When using filters for devices of Safety Class I Y-capacitors 8.1 RFI Suppression are being used to increase asymmetrical attenuation. These capacitors are connected line to ground. During normal The field of RFI suppression in Germany is governed by the operation leakage current flows to ground through these new EMV Rules (EMVG) of November 1992. Observance of capacitors. This leakage current must be limited for the simple the EMV Rules is controlled by the following standards: reason that in case of a faulty ground return within the device the body of the operator may serve as conductor for lethal 1. Subject Base Standards for RFI Emission voltages. CENELEC EN 50081-1 of 1.92 For this reason the permissible leakage currents are clearly DIN VDE 0839 Part 81-1/3.93 (German version) defined for every product group in the appropriate safety Electro magnetic compatibility for residential, trade and office regulations. areas as well as small industrial businesses. EN 50081-2 RFI Emission in industrial areas Typical values for internationally permissible leakage currents 2. Subject Base Standards for RFI Immunity are by safety classes: CENELEC EN 50082-1 of 1.92 DIN VDE 0839 Part 82-1/3.93 (German version) • Mobile devices of Safety Class I 0,75 mA Electro magnetic compatibility for residential, trade and office • Stationary motor units of Safety Class I 3.5 mA areas as well as small industrial businesses. • Stationary heating units of Safety Class I 5 mA EN 50082-2 RFI Immunity in industrial areas (Stationary devices - fixed mounted, or weighing in excess of 18 kg) 3. Product related Standards are • Devices of Safety Class II 0,25 mA EN 55011 EN 55013 EN 55013A • Encapsulated units 5 mA EN 55014 EN 55015 EN 55022 • Other units 3,5 mA EN 55020 EN 55104 EN 50091 EN 60555-2 EN 61000-3 Internationally permissible values of leakage currents for various applications: 8. 2. CE Symbol The CE Symbol has to be carried by all Ref. Analytical Medical DataProc.CalculatorInstrument devices covered by the Technical UL 0,5 mA 0,1 mA 5,0 mA 5,0 mA 0,5 mA Harmonisation Guidelines as of Jan 1st, (UL 1262) (UL 554) (UL 478) (UL 114) (UL 1244) 1996. The application of the CE 0,1 mA 3,5 mA 0,5 mA 3,5 mA Symbol is mandatory. After Dec 31st, (IEC 62A) (IEC 435) (IEC 380) (IEC 348) 1995 relevant products must not be issued to the market any longer without carrying the CE Symbol. More than half Measuring Leakage Current: of all presently sold technical industrial goods must thus For safety reasons during measurements an isolation carry the CE Symbol in the future. transformer should be used. The filter output must not be After publication of the respective locations where relevant connected to any load terminals. The current of each path European standards are found in the official gazettes the will have to be measured. manufacturers can at their own responsibility declare conformity of their products with these EMC safety Figure 14 Leakage Current Measurement requirements and can further mark their electrical devices with the EG standarized CE Symbols on their own. 7.5 Operating Voltage and Frequency The CE Symbol in a way represents a “passport” within the EC and guarantees the assurance of two attributes for the Variac Filter under test consumer/user: Reduced emission of and immunity from Isolation H H interferences as well as protection for the user. 50 Hz AC No connection If any one product is covered by more than one EC to load Input G terminals voltage guidelines requiring the application of the CE Symbol then N N the application of the CE Symbol signifies that the relevant Line Load requirements of these guidelines too are observed. 120V, 60 Hz The manufacturer is responsible for the observance of all or HN 250V, 50 Hz safety requirements for his products. If the product is 15001 V imported into the EC from any non-member country then the importer by law is the one firm or person issueing the 0,15µF product to the market and is thus equated with the EC manufacturer. All specifications subject to change. Consult Tyco Electronics for latest design specifications. 7 If any mechanical or electrical EMC problem cannot be solved by any one of our standard filters customers have access to a 8.3 New nominal voltage 230 V wide variety of thoroughly tested special filters. If any of these products still does not fit the specific needs and The new Harmonization Document HD 472 S1 authorized by there is no possible compromise, the costly way of designing CENELEC on 11/4/1988 changed the National Rules in two a customer specific filter is inevitable. steps until latest 1995. All accrueing tooling costs for new enclosures as well as Newly standardized values of nominal voltages: approvals (VDE, UL, CSA, SEV, etc.) requested by the customer 1. 400 V between outer conductors in a 4-conductor including the test sample necessary for each approval amount 3-phase supply network (3-phase operation) to a cost factor which usually requires manufacture and sales 2. 230 V between outer conductor and neutral (center-) of considerably large quantities. conductor Frame orders with time schedules up to one year as well as 3. 230 V between the outer conductors in a 3-conductor fixed shipping volumes allowing economically produceable 3-phase supply network (1-phase operation) lot sizes are also pre-requisite. Change-over deadlines Often only minor modifications have to be applied to standard filters. Willingness to compromise with mechanical layout by Until latest 1995 all energy supplying institutes had to change resort to existing enclosures and limiting the number of their present 220/380 V networks to the new voltages of 230/ approvals to those really necessary to market the devices 400 V +6%/-10%. cause immediate cost reduction. Countries with networks still operating at 240/415 V should adjust their voltages to 230/400 V +10%/-6%. Please contact us - the commonly found solution will satisfy At the end of the change-over period in the year 2003 the you. standardized voltage should be at 230/400 V +/-10%. Tyco Electronics will be happy to assist you in selecting the appropriate filter for your application. If your facility lacks time In order to advance harmonization in the EU and EFTA States and resources all your necessary measurements can easily be CENELEC Memorandum Nr.14 advised all appliance quick and reliably performed by the qualified personnel in our manufacturers to mark their products with the new nominal laboratory. voltages beginning latest 1/1/1993. This catalog contains only part of the comprehensive line of suppression filters produced by Tyco electronics. The filters depicted here mostly evolved out of specific requirements asked for by our worldwide customer base, have constantly been improved and were within their series extended by additional current classes. Widely accepted by our clientele they now form part of our standard products program. They are competitivelly priced and available at short notice. Example of interference Suppression Equipment characteristics without filtering Equipment characteristics with the appropriate filter 8 All specifications subject to change. Consult Tyco Electronics for latest design specifications. P o w e r E n t r y M o V D E Multifunction- Power-Entry-Module P-Series - IEC-plug with/without filter - Two pole line switch (optional) by Corcom - Double voltage selector - Combined fuse holder (twist protected) according IEC 950 - Line filter to 10 A/250 VAC (optional, also for medical applications) - Mounting cutout appr. 27 x 56 mm only - Filter mountable in the field Filter Selection Table Filter Selection Table for medical Applications Filter Max.current Shielding Inductance Capacity Filter Max.current Shielding Inductance Capacity type UL/VDE C C type UL/VDE C C Y X Y X S3A 3A yes 2x 2,0mH 3nF 0,047µF H3A 3A yes 2x 2,0mH - 0,047µF S30 3A no 2x 2,0mH 3nF 0,047µF H30 3A no 2x 2,0mH - 0,047µF S6A 6A yes 2x 0,66mH 3nF 0,047µF H6A 6A yes 2x 0,66mH - 0,047µF S60 6A no 2x 0,66mH 3nF 0,047µF H60 6A no 2x 0,66mH - 0,047µF SXA 10A yes 2x 0,27mH 3nF 0,047µF HXA 10A yes 2x 0,27mH - 0,047µF SX0 10A no 2x 0,27mH 3nF 0,047µF HX0 10A no 2x 0,27mH - 0,047µF Z6C 6A yes 2x 6,7mH 3nF 1,0µF L6C 6A yes 2x 6,7mH - 1,0µF ZXC 10A yes 2x 4,0mH 3nF 1,0µF LXC 10A yes 2x 4,0mH - 1,0µF Max. leakage current line to ground 0,5 mA at 250 VAC/50Hz Max. leakage current line to ground < 5 µA at 250 VAC/50Hz Ordering Information Example: PS 0 S S D S 3 A Ordering-Nr: PS0SSDS3A PS J O X S 0 0 0 Ordering-Nr: PSJ0XS000 Shielded line filter 3A/Shield type A No line filter Dual fuse holder Single fuse Dual voltage select (SMPS) Dual voltage select (serial/parallel) Double pole, line switch No line switch No fitting part J series fitting part Snap-in mounting Snap-in mounting Note 1: If ordered w/o filter max. current 10A Note 2: Z and L versions only available with screw mounting and without voltage selector (PE only) Note 3: No extender option possible when ordered with screw mounting (PE) All specifications subject to change. Consult Tyco Electronics for latest design specifications. 9 d u l e Electrical Schematic Dual voltage Switching power supply 115V 230V 115V 230V Power on/off Power on/off A Phase Power Phase G A 115V input Note 1 Note 2 B Note 1 Note 2 B Sel. C Note 1 C Note 2 115V Jumpers Note 1 Note 2 Neutral D Neutral H D Transformer primary SMPS Provision for Provision for single fusing single fusing Note 1: Jumpers are not required if a filter or interconnection module is used. Note 2: Space for filter Filter S3 / S6 / SX Filter H3 / H6 / HX C Y C Power C X X Power Device Device line line C Y Filter Z6 / ZX Filter L6 / LX Power C C C C X X X X Power Device Device line line Typ. Insertion Loss asym. sym. dB dB dB 90 90 90 80 80 80 70 70 70 60 60 60 50 50 50 40 40 40 30 30 30 20 20 20 10 10 10 0 0 0 0,1 1 10 30 0,1 1 10 30 0,1 1 10 30 S3 Frequency in MHz S6 Frequency in MHz SX Frequency in MHz dB dB dB 90 90 90 80 80 80 70 70 70 60 60 60 50 50 50 40 40 40 30 30 30 20 20 20 10 10 10 0 0 0 0,1 1 10 30 0,1 1 10 30 0,1 1 10 30 Frequency in MHz H3 H6 Frequency in MHz Frequency in MHz HX dB dB 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 10 0 0 0,01 0,1 1 10 30 0,01 0,1 1 10 30 Frequency in MHz Frequency in MHz Z6 ZX 10 All specifications subject to change. Consult Tyco Electronics for latest design specifications. Case Styles and typ. Sizes for Types without Filter PSO PMO 4,8 58,7 54,9 73 54,1 27,2 5,7 49 26,7 3,4 51,6 31,5 31 3,56 fl (2x) R 1,5 R 1,5 (1) 55,9 56 63,4 (2) 56,2 (4) 0,5 min (4) 0,5 min 26,9 + 0,203 - 0,000 28 Rear view Panel cutout without shield Panel cutout with shield and filter Note 4: For snap-in application, the 26.9 mm sides of the cutout must have a 0.5 mm radius on the installation side Panel thickness: 1) 0,8 - 2,0 mm 2) 2,1 - 2,9 mm 3) 1,5 - 2,3 mm Note 5: Terminals = 4,8 x 0,8mm; except Z and L version = 6,3mm Case Styles and typ. Sizes for Types with Filter PS with filter without shielding PE with filter and shielding type A 90¡ 1,5 51,6 49,5 52,3 40,0 4,8 4,8 58,7 Base module 54,9 Base module 58,2 with shielding "A" 3,3 Dia 5,8 Dia Filter module without shielding Filter module 20,9¡ Ground terminal Ground R 2,2 R 4,2 terminal 27,2 31,5 26,9 28,4 All specifications subject to change. Consult Tyco Electronics for latest design specifications. 11 Case Styles and typ. Sizes for Types with shielded Filter Panel cut-out for Shielding type A (part shielding) Shielding type B (full shielding) shield type A and B R 1,5 (1) 55,9 Note 4 Page 11 (2) 56,2 29,0 +0,3 Note: In case of B-shield no extender option possible Case Styles and typ. Sizes L / Z 40,1 104,7 12,7 11,9 59,9 58,2 54,6 28,5 Not available with selection power line voltages Accessories P-Series Description of possible Choices PA 100 Interconnect assembly; 4 x 150mm wire leads PA 105 Interconnect assembly; 2 x 150mm wire leads Extender for J-Series or C Fuse holder PA 101 Plug only PA 102 Pins only PA 103 Pins on reel PA 200 Fuse clip Optional switch PA 400 Extender J for J-Series PA 410 Extender L for L-Series; fit L-panel cut out; use two per module, without shield only PA 420 Extender C for FN-Series; fit FN-panel cut out; only snap-in versions SPST Voltage selection S for Switching mode power Optional filter RF Metal shield supplies PRSR Voltage selection X for dual primary transformers - parallel/serial 12 All specifications subject to change. Consult Tyco Electronics for latest design specifications. V D E Power Entry Module Filters M-Series according IEC 950 - Suppression filters for various applications - IEC-power line plug with fuses 2/5 x 20 or 1/6,3 x 32 mm to choose from - Two pole line switch - 110/120/230/240 V voltage selector - Suitable for medical equipment Power Entry Module Filters Type Max. current Max. leakage current Inductance Capacity Line switch Voltage Cover Mounting UL / VDE line to ground C C (switch on current) selector order no. X Y 3EXM4/E 3A / 2A 0,50mA 2x2,21mH 0,27+0,1µF 2x4nF – x – 3EXM1S/E 3A / 2A 0,50mA 2x2,21mH 0,27+0,1µF 2x4nF x(34A) - – 3EXM4S/E 3A / 2A 0,50mA 2x2,21mH 0,27+0,1µF 2x4nF x(34A) x – 3EZM4/E 3A / 2A 0,50mA 2x13,77mH 0,47+0,27µF 2x4nF – x 3EZM1S/E 3A / 2A 0,50mA 2x13,77mH 0,47+0,27µF 2x4nF x(34A) – – 3EZM4S/E 3A / 2A 0,50mA 2x13,77mH 0,47+0,27µF 2x4nF x(34A) x – 5EFM1/E 5A / 4A 0,50mA 2x0,93mH 0,009µF 2x3nF – – 3116 5EFM4/E 5A / 4A 0,50mA 2x0,93mH 0,009µF 2x3nF – x 3115 5EFM1S/E 5A / 4A 0,50mA 2x0,93mH 0,009µF 2x3nF x(34A) – 3114 5EFM4S/E 5A / 4A 0,50mA 2x0,93mH 0,009µF 2x3nF x(34A) x 3113 5EFM1C/E 5A / 4A 0,50mA 2x0,93mH 0,009µF 2x3nF – – 3116 Snap-in 5EFM4C/E 5A / 4A 0,50mA 2x0,93mH 0,009µF 2x3nF – x 3115 Snap-in 5EFM1SC/E 5A / 4A 0,50mA 2x0,93mH 0,009µF 2x3nF x(34A) – 3114 Snap-in 5EFM4SC/E 5A / 4A 0,50mA 2x0,93mH 0,009µF 2x3nF x(34A) x 3113 Snap-in 5EHM1/E 5A / 4A 0,005mA 2x0,93mH 0.009µF– –3116 5EHM4/E 5A / 4A 0,005mA 2x0,93mH 0,009µF– x3115 5EHM1S/E 5A / 4A 0,005mA 2x0,93mH 0,009µF x(34A) – 3114 5EHM4S/E 5A / 4A 0,005mA 2x0,93mH 0,009µF x(34A) x 3113 at 250VAC/50Hz Two pole,100000 operations at full load For medical Applications Type Max. current Max. leakage current Inductance Capacity Line switch Voltage Cover UL / VDE line to ground C C (switch on current) selector order No. X Y F-3374 3A / 2A 0,160 mA 2x16mH(L1) 0,47µF 2x1nF x(34A) - - at 250VAC/50Hz 2x0,47mH(L2) 0,1µF The M-Series offers the manufacturer of electronic equipment the maximum variety in a series of standard products with regard to the power line integration and various filter specifications. FILTER SPECIFICATIONS: XM-Series: Suitable for high performance applications. ZM-Series: Suitable for very high performance applications. FM-Series: Suitable for general purpose requirements. HM-Series: Suitable for medical equipment (also suitable for medical equipment permetting body contact) Fuse Change 5 x 20 fuse -> change to -> 6,3 x 32 fuse All specifications subject to change. Consult Tyco Electronics for latest design specifications. 13 Electrical Schematic FM & HM models for 2 and 4 voltages XM & ZM models for 2 and 4 voltages Customers transformer primaries Customers transformer primaries 120V 220V 120V 220V 100V 240V 100V 240V Power on/off Power on/off A A A A Note 2 Note 4 Note 4 Note 2 Neutral Neutral HB HB Note 1 Note 1 C C C C Note 3 D D D D E E E E Note 4 Note 4 J F F J F F Phase Phase G G FM & HM models for 1 voltage XM & ZM models for 1 voltage Power on/off Power on/off Note 2 Neutral Note 2 HB HB Neutral Note 1 Note 1 Note 3 JF J F Phase Phase G G F-3374 N HB Note 1: Provision for dual fusing (Euro standard) G L Note 2: Power on/off switch with suffix "S" only L 2 1 Note 3: HM models without Y-capacitors L JF Note 4: Switch or bridge between K-H and L-J Two more K- and L-connectors by 5EFM4 G Voltage Selection Before changing selected voltage, disconnect power cord • Open cover using a small screwdriver or equivalent and store fuse Selection of various power line voltages block in a save place. • Using the indicator pin, pull voltage selector card straight out of housing. • Turn card until desired voltage becomes readable at the bottom. • Place indicator pin pointing up when desired voltage is readable at the bottom. 100V 120V 230V 240V • Insert voltage selector card into the housing with printed side facing toward the IEC connector and indicator pin toward case maker. • Replace fuse block and cover making sure that the indicator pin shows the desired voltage. Typ. Insertion Loss asym. sym. dB dB 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 10 0 0 0,1 1 10 30 0,1 1 10 30 XM Frequency in MHz ZM Frequency in MHz 14 All specifications subject to change. Consult Tyco Electronics for latest design specifications. Case Styles and typ. Sizes for M-Modules with Filter 3EXM1S/3EZM1S/F-3374 3EXM4/3EZM4 IEC connector, DPST on/off switch, selectable IEC connector, voltage selector, selectable fuse holder fuse holder Thread 75,9 ±0,5 6-32 x 1/4 Thread 83,8 ±0,5 6-32 x 1/4 29,4 ±0,5 28,7 ±0,5 47,8 ±0,5 78,5 47,8 ±0,5 78,5 100V USE ONLY WITH 120V 250V FUSES USE ONLY WITH 230V * 27,9 250V FUSES DISCONNECT POWER 240V BEFORE REPLACING FUSES 27,9 DISCONNECT POWER * BEFORE REPLACING FUSES 43,7 74,2 81,8 43,7 84,3 ±0,5 91,9 ±0,5 Side view 98,6 Side view 105,9 * Self aligning M3 screws 3EXM4S/3EZM4S 5EHM1 / 5EFM1 IEC connector, DPST on/off switch, voltage selector, IEC connector, selectable fuse holder selectable fuse holder Thread 96,5 ±0,5 6-32 x 1/4 USE ONLY WITH 29,7 –0,5 250V FUSES 27,9 DISCONNECT POWER BEFORE REPLACING FUSES 47,8 ±0,5 78,5 62,0 55,6 72,1 ±0,5 100V USE ONLY WITH 120V 250V FUSES * 230V 86,1 Side view 27,9 DISCONNECT POWER 240V BEFORE REPLACING FUSES 94,0 43,7 27,9 104,1 ±0,5 Side view 118,1 55,6 Snap-in version All backplate terminals 2.8 mm flat type plugs/holes 1.4 Dia ±0,1 Exception: Solder lug ground terminal (wire wrap suitable) mounting holes 3.9 Dia. 5EHM4 / 5EFM4 5EHM1S / 5EFM1S IEC connector, voltage selector, selectable fuse holder. IEC connector, DPST on/off switch, selectable Connection of external Switch fuse holder USE ONLY WITH 100V USE ONLY WITH 250V FUSES 120V 27,9 250V FUSES 230V 27,9 DISCONNECT POWER BEFORE REPLACING FUSES DISCONNECT POWER 240V BEFORE REPLACING FUSES 55,6 81,8 55,6 74,2 91,9 ±0,5 84,3 ±0,5 Side view Side view 105,9 98,6 27,9 27,9 55,6 55,6 Snap-in version Snap-in version Typ. Insertion Loss asym. sym. dB dB dB 90 90 90 80 80 80 70 70 70 60 60 60 50 50 50 40 40 40 30 30 30 20 20 20 10 10 10 0 0 0 0,15 1 10 30 0,01 0,1 1 10 30 0,15 1 10 30 Frequency in MHz Frequency in MHz HM Frequency in MHz F-3374 FM All specifications subject to change. Consult Tyco Electronics for latest design specifications. 15 Case Styles and typ. Sizes for M-Modules with Filter 5EHM4S / 5EFM4S 5EFM1C IEC connector, DPST on/off switch, voltage selector, IEC connector, selectable fuse holder, snap-in selectable fuse holder Ø3,0 USE ONLY WITH 250V FUSES 29,2±0,25 100V USE ONLY WITH DISCONNECT POWER 250V FUSES 120V BEFORE REPLACING FUSES 27,9 230V DISCONNECT POWER 240V BEFORE REPLACING FUSES 53,8 94,0 63,2±0,25 104,1 ±0,5 64,8 max 32,9 1,52 Side view 118,1 62,0 max 27,9 max 27,9 26,9 53,8 55,6 9,9 Snap-in version 21,1 7,1 5EFM4C 5EFM4SC IEC connector, voltage selector, IEC connector, DPST on/off switch, voltage selector, selectable fuse holder, snap-in selectable fuse holder, snap-in 3,0 Dia 3,3 Dia 100V USE ONLY WITH 120V 250V FUSES 29,1 29,2±0,25 230V 100V USE ONLY WITH DISCONNECT POWER 240V BEFORE REPLACING FUSES 120V 250V FUSES 230V DISCONNECT POWER BEFORE REPLACING FUSES 240V 75,4±0,25 92±0,25 96,8 33 77,0 32,9 1,5 1,5 27,9 94 74,2 27,9 26,9 26,9 53,7 55,6 9,9 9,9 21,1 21,1 7 7,1 5EFM1SC IEC connector, DPST on/off switch, selectable fuse holder, snap-in 33 max 38,1±0,25 USE ONLY WITH 250V FUSES DISCONNECT POWER BEFORE REPLACING FUSES 83±0,25 84,6 32,9 1,5 27,9 81,8 26,9 55,6 max 9,9 21,1 7,1 16 All specifications subject to change. Consult Tyco Electronics for latest design specifications. Case Styles and typ. Sizes for M-Modules without Filter 6VM1C 6VM1SC IEC connector, selectable fuse holder, snap-in IEC connector, DPST on/off switch, selectable fuse holder, snap-in USE ONLY WITH 250V FUSES DISCONNECT POWER USE ONLY WITH BEFORE REPLACING FUSES 250V FUSES DISCONNECT POWER BEFORE REPLACING FUSES 62,0 1,52 64,8 32,9 84,6 32,9 1,5 27,9 27,9 81,8 26,9 26,9 9,9 9,9 6VM4C 6VM4SC IEC connector, DPST on/off switch, IEC connector, DPST on/off switch, selectable fuse holder, snap-in selectable fuse holder, snap-in 100V USE ONLY WITH 120V 100V USE ONLY WITH 250V FUSES 230V 120V 250V FUSES DISCONNECT POWER 240V 230V BEFORE REPLACING FUSES DISCONNECT POWER 240V BEFORE REPLACING FUSES 77,0 32,9 96,8 1,5 33 1,5 27,9 74,2 27,9 94 26,9 26,9 9,9 1,0 6VM4S/6VM2S 6VM1S IEC connector, DPST on/off switch, voltage selector, IEC connector, DPST on/off switch, selectable fuse holder selectable fuse holder 100V USE ONLY WITH USE ONLY WITH 250V FUSES 250V FUSES 120V C C 230V DISCONNECT POWER DISCONNECT POWER 240V BEFORE REPLACING FUSES BEFORE REPLACING FUSES E E C C Snap-in version Snap-in version 6VM4/6VM2 6VM1 IEC connector, voltage selector, selectable fuse holder IEC connector, selectable fuse holder 100V USE ONLY WITH 120V 250V FUSES C 230V USE ONLY WITH DISCONNECT POWER 250V FUSES 240V BEFORE REPLACING FUSES C DISCONNECT POWER BEFORE REPLACING FUSES E D E B C A C Snap-in version Typ. dimensions Snap-in version All backplate terminals 2.8 Dia. Exception: silder lug ground terminal (wire wrap suitable) mounting holes 3.94 Dia. Holes 1.4 Dia±0.1 VM-models suitable for front and back mounting All specifications subject to change. Consult Tyco Electronics for latest design specifications. 17 Power Entry Module without Filter Case sizes Type A (max) B (±0,25) C (max) D (max) E (max) F (max) 6VM1 86,1 72,1 27,9 62,0 36,8 63,5 6VM1C 64,8 - 27,9 62,0 36,8 63,5 6VM1S 105,9 91,9 27,9 81,8 36,8 83,3 6VM1SC 84,6 - 27,9 81,8 36,8 83,3 6VM2 98,6 84,3 27,9 74,2 36,8 75,7 6VM2S 118,1 104,1 27,9 94,0 36,8 95,5 6VM4 98,6 84,3 27,9 74,2 36,8 75,7 6VM4C 77,0 - 27,9 74,2 36,8 75,7 6VM4S 118,1 104,1 27,9 94,0 36,8 95,5 6VM4SC 96,8 - 27,9 94,0 36,8 95,5 AB 3,3 R 0,1 R 4,5 4,5 VM und FM models suitable xxxM1: 72,1 ±0,5 63,3 ±0,3 14,5 for front and back mounting. xxxM1S: 91,9 ±0,5 83,1 ±0,3 29 14,5 XM and ZM models for back xxxM4: 84,3 ±0,5 75,4 ±0,3 29,1 mounting only Holes xxxM4S: 104,1 ±0,5 95,2 ±0,3 4,3 Dia 4,3 Dia B F A B Accessories for M-Modules These plugs have been designed for all M-Series modules in order to accomplish simple connection. Plugs are available with or without colour coded wire leads. 216,9 ±12,7 D F E 10 15,8 13,5 Dia MA 100 3 9,8 Dia 14 21,9 20 35 F E D A B C A 27,3 Part No. Shroud-lupolen (HDPE/MDPE) Assembly MA - 100 for M1 - versions (62,0) 41 - 3116 - AO Plug only MA - 101 for M4 - versions (74,0) 41 - 3115 - AO Pins on stripes (100) MA - 102 for M1S - versions (81,8) 41 - 3114 - AO Pins on reel (7000) MA - 103 for M4S - versions (94,0) 41 - 3113 - AO Note for tools: pliers/Molex:HTR 2445 A Material UL-94/2 listed Voltage selection card 120V / 240V (VM2) MA - 302 Medical safety bracket kit 100V / 120V / 230V / 240V (VM4) MA - 304 for use with HM models MA - 400 The modules are standard delivered with one card (UL - 544) 18 All specifications subject to change. Consult Tyco Electronics for latest design specifications. V D E Power Entry Module according IEC 950 Filters EDL-, EHL-Series Compact units for international applications - IEC-Connector - Fuse blocks for 2/5 x 20 or 1/6,3 x 32 fuses - Choice of 4-voltage selector or power line switch - Operating voltage110/120/230/240 VAC - Further standard types on request Type Max. current Inductance Capacity Line switch 4-fold Fuses Mounting UL/VDE C C (switch on current) voltage X Y 2EDL4 2 2x0,79mH 0,047µF 2x2,8nF x 1 Flange 2EDL4C 2 2x0,79mH 0,047µF 2x2,8nF x 1 Snap-in 2EDL4M 2 2x0,79mH 0,047µF 2x2,8nF x 2 Flange 2EDL4CM 2 2x0,79mH 0,047µF 2x2,8nF x 2 Snap-in 4EDL4 4 2x0,35mH 0,047µF 2x2,8nF x 1 Flange 4EDL4C 4 2x0,35mH 0,047µF 2x2,8nF x 1 Snap-in 4EDL4M 4 2x0,35mH 0,047µF 2x2,8nF x 2 Flange 4EDL4CM 4 2x0,35mH 0,047µF 2x2,8nF x 2 Snap-in 6EDL4 6 2x0,27mH 0,047µF 2x2,8nF x 1 Flange 6EDL4C 6 2x0,27mH 0,047µF 2x2,8nF x 1 Snap-in 6EDL4M 6 2x0,27mH 0,047µF 2x2,8nF x 2 Flange 6EDL4CM 6 2x0,27mH 0,047µF 2x2,8nF x 2 Snap-in 2EDL1S 2 2x0,79mH 0,047µF 2x2,8nF x(51A) 1 Flange 2EDL1SC 2 2x0,79mH 0,047µF 2x2,8nF x(51A) 1 Snap-in 2EDL1SM 2 2x0,79mH 0,047µF 2x2,8nF x(51A) 2 Flange 2EDL1SCM 2 2x0,79mH 0,047µF 2x2,8nF x(51A) 2 Snap-in 4EDL1S 4 2x0,35mH 0,047µF 2x2,8nF x(51A) 1 Flange 4EDL1SC 4 2x0,35mH 0,047µF 2x2,8nF x(51A) 1 Snap-in 4EDL1SM 4 2x0,35mH 0,047µF 2x2,8nF x(51A) 2 Flange 4EDL1SCM 4 2x0,35mH 0,047µF 2x2,8nF x(51A) 2 Snap-in 6EDL1S 6 2x0,27mH 0,047µF 2x2,8nF x(51A) 1 Flange 6EDL1SC 6 2x0,27mH 0,047µF 2x2,8nF x(51A) 1 Snap-in 6EDL1SM 6 2x0,27mH 0,047µF 2x2,8nF x(51A) 2 Flange 6EDL1SCM 6 2x0,27mH 0,047µF 2x2,8nF x(51A) 2 Snap-in Two pole, 10000 One 6,3x32 mm operations at full load or two 5x20 mm Max. leakage current line to ground 0,5 mA at 250 VAC/50 Hz Type Max.current Inductance Capacity Line switch 4-fold Fuses Mounting UL/VDE C (switch on current) voltage X 6EHL4 6 2x0,58mH 0,047µF x 1 Flange 6EHL4C 6 2x0,58mH 0,047µF x 1 Snap-in 6EHL4M 6 2x0,58mH 0,047µF x 2 Flange 6EHL4CM 6 2x0,58mH 0,047µF x 2 Snap-in 6EHL1S 6 2x0,58mH 0,047µF x(51A) 1 Flange 6EHL1SC 6 2x0,58mH 0,047µF x(51A) 1 Snap-in 6EHL1SM 6 2x0,58mH 0,047µF x(51A) 2 Flange 6EHL1SCM 6 2x0,58mH 0,047µF x(51A) 2 Snap-in Max. leakage current line to ground 5 µA at 250 VAC/50 Hz Typ. Insertion Loss asym. sym. dB dB 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 10 0 0 0,1 1 10 30 0,1 1 10 30 Frequency in MHz 4EDL 2EDL Frequency in MHz All specifications subject to change. Consult Tyco Electronics for latest design specifications. 19 Voltage Selection Before changing selected voltage, disconnect power cord. Open cover using a small screwdriver or equivalent. Rotate voltage selector to the desired voltage and replace cover. Ordering notes: with M = Fuse block for 2/5 x 20 DIN fuses Without M = Fuse block for 1/6,3 x 32 DIN fuses Further combinations voltage selector/fuse block on request. Case Styles and typ. Sizes Flange mounted version Snap-in version 54 54 58 ±0,3 ±0,3 ±0,3 28,9 28,9 5,5 5,5 51 51 ±0,3 ±0,3 ±0,3 ±0,3 32 40±0,3 ±0,3 2,0 R 50±0,3 AC E 2,0 R B D F 3,2 Dia G H 2a 2 56 ±1 1 1a G H 58 56 0,5 R. ±0,3 ±1 Faston 2,8 28,5±0,3 Faston switch 4,8 Panel thickness Hole 1,4 ±0,1 Dia 28,5±0,3 0,8-2,0 mm 55,9+0,2 2,1-3,2 mm 56,2+0,2 Faston 2,8 For snap-in version the cutout measuring 28.5 must have a 0.5 mm round off 40±0,3 Faston switch 4,8 on the mounting side. Mounting holes 3,2 Dia Electrical Schematic DL models with switch DL models with 4 Voltages Power on/off H F F F Neutral Neutral EE 11a Power Power D D line Device line Device C C Phase 2 2a B Phase G AA G 240V 100V 120V 220V Note: EHL-models without Y-capacity Typ. Insertion Loss in dB asym. sym. dB dB 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 10 0 0 0,1 1 10 30 0,1 1 10 30 Frequency in MHz 6EDL Frequency in MHz 6EHL 20 All specifications subject to change. Consult Tyco Electronics for latest design specifications. Customers transformer primaries Customers transformer primaries Accessories for EDL/EHL-Series 41-3150-AO 41-3150-AA Round cable fitting Flat cable fitting 6,25±0,25 46 42,0 46,0 ±0,25 13 Dia 9,8 Dia 56 ±0,25 45¡ 10 23,0 ±0,5 3 27,5±0,25 22,5±1,0 45¡ 28,5 7,0±1,0 55,0±0,5 Color black, material UL-94 Part No. Shroud Round cable fitting 41-3150-AO Flat cable fitting 41-3150-AA Voltage selection drum for use with all L4 models 115V / 115V / 230V / 230V 72-2695-BO 110V / 230V / 240V 72-2954-AO 100V / 120V/ 230V / 240V 72-2695-AO 115V / 230V 72-2955-AO 100V / 120V / 220V / 240V 72-2695-CO The EDL- / EHL-Series are by standard equipped and held in stock with a voltage selector for 100V/120V/220V/240V as well as one fuse holder for North American fuses (6,3 x 32 mm) or two holders for European fuses (5 x 20 mm with "M" design). Different requirements regarding voltage selection or fuse holders can either be realized by parts offered as accessories or taken into consideration directly from manufacturing in case of sufficient order volume and delivery time. Fuse holder Accomodates DIN-fuse 81-2694-AO 5 x 20 mm Accommodates North American fuse 81-2693-AO 6,3 x 32 mm Standard With 1 fuse: North American fuse holder With 2 fuses: 2 x DIN fuse holder All specifications subject to change. Consult Tyco Electronics for latest design specifications. 21 V D E Power Entry Module with IEC Connector according IEC 950 and Switch F-3558 Fuse holder (5 x 20) and filter Type Max. current Max. leakage current Inductance Capacity VDE line to ground L C C 1 X Y F-3558 6A 0,5 mA 2 x 0,93mH 0,1µF 2x3nF with discharge resistor 1 M1 with 250VAC/50Hz On request also available in 1A and 3A units. Case Style and typ. Sizes Panel cutout for frontmounting 5 50 4,8mm plug 29 2 pieces 3 65 60 59 6,3mm plug 44 40 40 52 Electrical Schematic Power Device Typ. Insertion Loss in dB asym. sym. dB 90 80 70 60 50 40 30 20 10 0 0,1 1 10 30 Frequency in MHz F3558 22 All specifications subject to change. Consult Tyco Electronics for latest design specifications. V D E for Series FLA, XLA and ZLA Power Entry Module Filters according IEC 950 LA-Series - IEC-Connector - Fuse block 5 x 20 or 6,3 x 32 mm - Two pole line switch (illuminated on request) - Voltage selector 110 / 120 V or 230 / 240 V - Further types on request - Illuminated line switch F-7332A Type Max. current Max. Inductance Capacity Line switch Terminals Application UL/VDE voltage L C C 1 x y 5EFLA2S 5A/4A 250 VAC 2x0,93 mH 0,009µF 2x3nF >50000 operations Normal attenuation at full load Fastons 3EXLA2S 3A/2A 250 VAC 2x2,3 mH 0,27+0,1µF 2x4nF 2,79 mm High attenuation 35A 3EZLA2S 3A/2A 250 VAC 2x13,77 mH 0,47x0,27µF 2x4nF switch on current Very high attenuation Max. leakage current line to ground 0.5 mA at 250 VAC/50 Hz All models are available with a cover to prevent electrical as well as with a common line plug. Filters for Switching Power Supplies, illuminated Type Max. current Max. Inductance Capacity Line switch Terminals Application UL/VDE voltage L C C 1 x y F7332A 3A/2A 250 VAC 2x13,77 mH 0,47x0,27µF 2x4nF s.a. s.a. Very high attenuation Max. leakage current line to ground 0.5 mA at 250 VAC/50 Hz All models are available with a cover to prevent electrical as well as with a common line plug. Electrical Schematic A B C 5EFLA2S 3EXLA2S & 3EZLA2S 120V 240V A or D A B C A Power on/off A D E F B B 120V 240V A or D Neutral C Y C Power on/off D E F A A Ground C X D D L B B 1 Neutral E E C C Y Ground F F D D Phase G E E Transformer primary A B C F F F7332A Phase G 120V 240V A or D Transformer primary Power on/off A A D E F B B Neutral C Ground D D E E F F Phase G Transformer primary F-7332A with var. switches Typ. Insertion Loss asym. sym. dB dB dB 90 90 90 80 80 80 70 70 70 60 60 60 50 50 50 40 40 40 30 30 30 20 20 20 10 10 10 0 0 0 0,1 1 10 30 0,01 0,1 1 10 30 0,01 0,1 1 10 30 Frequency in MHz Frequency in MHz Frequency in MHz XLA FLA ZLA All specifications subject to change. Consult Tyco Electronics for latest design specifications. 23 Case Styles and typ. Sizes 5EFLA2S, 3EXLA2S & 3EZLA2S, F-7332A 2,4 R 50±0,5 30 Type 5EFLA2S 78,0 max 39,9±0,5 Type 3EXLA2S/3EZLA2S 104,6 max 61,5 +0,5 65,3 3,5 Dia 61,2 ±0,5 110-120 30,23 +0,5 40 Faston 2,79 Faston switch 2,79 Hole 3,20 Exception: Solder lug ground terminal (Wire wrap suitable). By using 6.3 x 32 fuses use left insertion. Accessories for LA - Series and F7332A 35 Part No. 2S Cover 41 - 3116 - A0 9,8 Dia Material UL-94 13 Dia 10 3 216,9±12,7 D E F 20 MA 1200 24,6 20 D E F AB C Assembly Assembly MA - 1200 Plug only MA - 1201 These plugs have been designed for all LA-Series + F-7332 Pins on stripes (100) MA - 102 modules in order to accomplish simple connection. Plugs are available with or without colour coded wire leads. Pins on reel (7000/MBM) MA - 103 24 All specifications subject to change. Consult Tyco Electronics for latest design specifications. 230-240 Power Entry Modules with/without Filters according IEC 950 J-Series - Voltage selector, fuse and IEC- connector - Selectable voltages - Type 6J4 with attached interference suppression filter Type Max. current Inductance Capacity Power connector Terminals UL/VDE C C X Y 6VJ1 6A According to UL- and IEC- Back plane terminals suitable for Without filter standards as well as soldering, wire wrap and crimp-on 6J4 6A 2x0,46mH 0,009µF 2x2,8nF CEE-public. 22 Typ VI lugs such as MOLEX Nr.2123 With filter Max. leakage current line to ground: type 6VJ1 5 µA, type 6J4 0,5 mA at 250 VAC/50 Hz Electrical Schematic 120V 220V 6VJ1 6J4 240V 100V 120V 220V 240V 100V Note 2 A A P A A Power line switch Power line switch R B B S P Off Off B B C C H Ground On On J C DD Ground DD E E N K E F F M Note 1 L F Transformer primary Note 1: Jumper required with N Note 1 Pilot light N Transformer primary P SPST switch Pilot light Note 2: Jumper required without input filtering Accessories J-Series Case Styles and typ. Sizes Mounting diagram Note 1: Fuse cover window open Note 2: Panel thickness 1.5-2.2 mm Part No. Flat pin plug Note 2 2,8 Voltage selector card 115V / 230V JA - 302 100V / 120V / 230V / 240V* JA - 304 29,7 * Standard 6VJ1 68,1 38,6 47,5 Mounting clip up to 6J4 69,9 6VJ1 6J4 3,2 mm thickness JA - 403 Note 1 27,0 29,2 ±0,07 59,0 240V Line V. +5-10% 100V 120V 220V 5,3 Fuse 48-440 !50 VA Max. 500mA 250mA 66,0 Housing ±0,07 67,3 A B C 76,2 Device rating label Typ. Insertion Loss asym. sym. AB C VA Fuse Part No. dB Max. 100/120 230/240 90 80 25 250 mA 125 mA 85 - 1500 70 50 500 mA 250 mA 85 - 1501 60 50 100 1 A 500 mA 85 - 1502 40 200 2 A 1 A 85 - 1503 30 250 2,5 A 1,25 A 85 - 1504 20 300 3 A 1,5 A 85 - 1505 10 400 4 A 2 A 85 - 1506 0 0,1 1 10 30 500 5 A 2,5 A 85 - 1507 6J4 Frequency in MHz 600 6 A 3 A 85 - 1508 All specifications subject to change. Consult Tyco Electronics for latest design specifications. 25 V D E IEC Connector Filters with double Pole Switch according IEC 950 C-Series - Three function PEM combining IEC socket DPST switch and filter - Available up to 10A - Compact size - Also available w/o filter Type Max. current Inductance Capacity Switch Terminals UL/VDE Cx Cy 10CS1 / 10CE1 10A - - - x 4,8mm x 0,8mm flat connectors 1CFS1 / 1CFE1 1A 2 x 10mH 0,1µF 2 x 3nF x 6,35mm x 0,8mm flat connectors 3CFS1 / 3CFE1 3A 2 x 2,43mH 0,1µF 2 x 3nF x 6,35mm x 0,8mm flat connectors 6CFS1 / 6CFE1 6A 2 x 0,82mH 0,1µF 2 x 3nF x 6,35mm x 0,8mm flat connectors 10CFS1 / 10CFE1 10A 2 x 0,31mH 0,1µF 2 x 3nF x 6,35mm x 0,8mm flat connectors For medical Applications Type Max. current Inductance Capacity Switch Terminals UL/VDE Cx Cy 1CHS1 / 1CHE1 1A 2 x 10mH 0,1µF- x 6,35mm x 0,8mm flat connectors 3CHS1 / 3CHE1 3A 2 x 2,43mH 0,1µF- x 6,35mm x 0,8mm flat connectors 6CHS1 / 6CHE1 6A 2 x 0,82mH 0,1µF- x 6,35mm x 0,8mm flat connectors 10CHS1 / 10CHE1 10A 2 x 0,31mH 0,1µF- x 6,35mm x 0,8mm flat connectors Electrical Schematic F models Device Power line Typ. Insertion Loss asym. sym. dB dB 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 10 0 0 0,1 1 10 30 0,1 1 10 30 Frequency in MHz 1CFS1/1CFE1 3CFS1/3CFE1 Frequency in MHz dB dB 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 10 0 0 0,1 1 10 30 0,1 1 10 30 6CFS1/6CFE1 Frequency in MHz 10CFS1/10CFE1 Frequency in MHz 26 All specifications subject to change. Consult Tyco Electronics for latest design specifications. Case Styles and typ. Sizes Flange / CE Snap-in / CS 41,0 35,8 35,8 90° Countersunk 41,0 17,9 26,9 + 0,2 26,9 + 0,2 31,2 max Mounting holes 36,0 + 0,2 Dia. 3,18 (2) 44,2 max Filtered / CFS, CFE Unfiltered / CS, CE 6,35mm x 0,8mm Faston (3 places) 4,8mm x 0,8mm Faston (3 places) 41,2 max 64,3 max 5,4 max 24,6 max Panel cutout for CS, CE (CFE) 28,5 1,5-R max Snap-in + 0,2 Flange x 39,7 max Accessories for C-Series x: With K-extender 36,0 Available extenders are: add 3,3mm to + 0,2 height PA420 - extender C increases height by 5,1mm PA400 - extender J increases height by 10,7mm Panel cutout for thickness of 0,8-2,5mm. CA430 - extender K increases height by 3,3mm Not recommended for plastic panels. For snap-in application, the D sides of the cutout must have a 0,5mm radius on the installation side. Snap-in models allow front mounting only. All specifications subject to change. Consult Tyco Electronics for latest design specifications. 27 V D E IEC Connector Filters with Fuses according IEC 950 EGG-Series - IEC-connector including 1 or 2 5 x 20 fuses - Universal filter with high attenuation - C-Version suppresses RF noise between equipment ground and protective ground Type Max. Induct. Type Max. Induct. Type Max. Inductance Capacity Fuses Ground Terminals current current current line UL/VDE UL/VDE UL/VDE Cx Cy induct. 1EGG1-1 1A 2x10mH 3EGG1-1 3A 2x2mH 6EGG1-1 6A/5A 2x0,93mH 0,1µF 2x3nF 1 Faston 1EGS1-1 1A 2x10mH 3EGS1-1 3A 2x2mH 6EGS1-1 6A/5A 2x0,93mH 0,1µF 2x3nF 1 Faston 1EGG1C-1 1A 2x10mH 3EGG1C-1 3A 2x2mH 6EGG1C-1 6A/5A 2x0,93mH 0,1µF 2x3nF 1 x Faston 1EGG1-2 1A 2x10mH 3EGG1-2 3A 2x2mH 6EGG1-2 6A/5A 2x0,93mH 0,1µF 2x3nF 2 Faston 1EGS1-2 1A 2x10mH 3EGS1-2 3A 2x2mH 6EGS1-2 6A/5A 2x0,93mH 0,1µF 2x3nF 2 Faston 1EGG1C-2 1A 2x10mH 3EGG1C-2 3A 2x2mH 6EGG1C-2 6A/5A 2x0,93mH 0,1µF 2x3nF 2 x Faston 1EGG8-1 1A 2x10mH 3EGG8-1 3A 2x2mH 6EGG8-1 6A/5A 2x0,93mH 0,1µF 2x3nF 1 Wire 1EGG8C-1 1A 2x10mH 3EGG8C-1 3A 2x2mH 6EGG8C-1 6A/5A 2x0,93mH 0,1µF 2x3nF 1 x Wire 1EGG8-2 1A 2x10mH 3EGG8-2 3A 2x2mH 6EGG8-2 6A/5A 2x0,93mH 0,1µF 2x3nF 2 Wire 1EGG8C-2 1A 2x10mH 3EGG8C-2 3A 2x2mH 6EGG8C-2 6A/5A 2x0,93mH 0,1µF 2x3nF 2 x Wire Max. leakage current line to ground 0,5 mA at 250 VAC/50 Hz For medical Applications Type Max. Induct. Type Max. Induct. Type Max. Inductance Capacity Fuses Ground Terminals current current current line UL/VDE UL/VDE UL/VDE Cx induct. 1EHG1-2 1A 2x10mH 3EHG1-2 3A 2x2mH 6EHG1-2 6A/5A 2x0,93mH 0,1µF 2 – Faston Max. leakage current line to ground 5 µA at 250 VAC/50 Hz Electrical Schematic EGG with ground line inductance (C-version) EHG Power line Power line Device Device EGG-1 / EGS-1 EGG-2 / EGS-2 Power line Device Power line Device Typ. Insertion Loss asym. sym. dB dB dB 90 90 90 80 80 80 70 70 70 60 60 60 50 50 50 40 40 40 30 30 30 20 20 20 10 10 10 0 0 0 0,1 1 10 30 0,1 1 10 30 0,1 1 10 30 Frequency in MHz Frequency in MHz 3EGG1/3EGS1 Frequency in MHz 3EGG1C 1EGG1/1EGG1C/ 1EGS1 28 All specifications subject to change. Consult Tyco Electronics for latest design specifications. Case Styles and typ. Sizes 31,0 2,5 33 EGG1 / EHG 1 44,2 36 28,0 16,8 28,7 54,5 4,5 M3 33 32,8 32,8 +0,3 29 42,0 +0,3 R3,5 6,35 Faston 51,7 36+0,2 31,0 2,5 33,0 EGG1C 36,0 44,0 28,0 28,7 12,2 ±0,2 19,0 6,35 4,5 Faston (3) M3 32,8 +0,3 33,0 -0 29,0 50,9 +0,3 R3,5 -0 62,2 36,0±0,2 31 50,9 140,0 33,0 EGG8 / EGG8C Blue 36 Green/Yellow 44 28,0 12,2 ±0,2 Brown 2,5 19 4,5 M3 33 32,8 +0,3 29 +0,3 3,5 R 36+0,2 0,7 EGS 28,7 36,0 34,0 18,0 max. 54,0 max. 37,0 51,5 max. 31,5 32,5 35,0 32,8 max. 12,5 R 3,5 5,0 6,3 3,0 Faston (3) Typ. Insertion Loss asym. sym. dB dB 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 10 0 0 0,1 1 10 30 0,1 1 10 30 Frequency in MHz Frequency in MHz 6EGG1C 6EGG1/6EGS1 All specifications subject to change. Consult Tyco Electronics for latest design specifications. 29 V D E IEC Connector Filters EBF-Series - Accessory outlet filter according IEC 950 Type Max.current Inductance Capacity Terminals Sizes UL/VDE C C AB C D E Y X 1EBF1 1A 2x10mH 2x3nF 0,047µF Faston 65,3 33,0 29,5 40,01 50,5 1EBF4 1A 2x10mH 2x3nF 0,047µF Wire 52,1 33,0 29,5 40,01 50,5 3EBF1 3A 2x1,5mH 2x3nF 0,047µF Faston 65,3 33,0 29,5 40,01 50,5 3EBF4 3A 2x1,5mH 2x3nF 0,047µF Wire 52,1 33,0 29,5 40,01 50,5 6EBF1 6A 2x0,47mH 2x3nF 0,047µF Faston 65,3 33,0 29,5 40,01 50,5 6EBF4 6A 2x0,47mH 2x3nF 0,047µF Wire 52,1 33,0 29,5 40,01 50,5 10EBF1 10A 2x0,35mH 2x3nF 0,047µF Faston 65,3 33,0 29,5 40,01 50,5 10EBF4 10A 2x0,35mH 2x3nF 0,047µF Wire 52,1 33,0 29,5 40,01 50,5 Max. leakage current line to ground 0.42 mA at 250 VAC/50 Hz Case Styles and typ. Sizes EBF1 EBF4 E B A D 5,8 Dia 3,5 Dia C C 40,0 D Typical length 33,6 E B A 100 mm 3,6 Dia 25,7 Recommended 5,1R panel cutouts Electrical Schematic Device Power line Typ. Insertion Loss asym. sym. dB dB dB 90 90 90 80 80 80 70 70 70 60 60 60 50 50 50 40 40 40 30 30 30 20 20 20 10 10 10 0 0 0 0,1 1 10 30 0,1 1 10 30 0,1 1 10 30 1EBF Frequency in MHz 3EBF Frequency in MHz Frequency in MHz 6EBF 30 All specifications subject to change. Consult Tyco Electronics for latest design specifications. V D E IEC Connector Filters EEA-/EEB-Series according IEC 950 - Best price/performance ratio - Compatible with many standard filters Type Max.current Inductance Capacity Terminals Type Max.current Inductance Capacity Terminals UL/VDE C C UL/VDE C C Y X Y X 1EEA1 1A 2x 10mH 3nF 0,009µF Faston 1EEB1 1A 2x 10mH 3nF 0,047µF Faston 1EEAP 1A 2x 10mH 3nF 0,009µF PCB 1EEBP 1A 2x 10mH 3nF 0,047µF PCB 1EEA2 1A 2x 10mH 3nF 0,009µF90° Faston 1EEB2 1A 2x 10mH 3nF 0,047µF90° Faston 1EAS1 1A 2x 10mH 3nF 0,009µF Faston 1EBS1 1A 2x 10mH 3nF 0,047µF Faston/snap-in 3EEA1 3A 2x 1,5mH 3nF 0,009µF Faston 3EEB1 3A 2x 1,5mH 3nF 0,047µF Faston 3EEAP 3A 2x 1,5mH 3nF 0,009µF PCB 3EEBP 3A 2x 1,5mH 3nF 0,047µF PCB 3EEA2 3A 2x 1,5mH 3nF 0,009µF90° Faston 3EEB2 3A 2x 1,5mH 3nF 0,047µF90° Faston 3EAS1 3A 2x 1,5mH 3nF 0,009µF Faston 3EBS1 3A 2x 1,5mH 3nF 0,047µF Faston/snap-in 6EEA1 6A 2x 0,47mH 3nF 0,009µF Faston 6EEB1 6A 2x 0,47mH 3nF 0,047µF Faston 6EEAP 6A 2x 0,47mH 3nF 0,009µF PCB 6EEBP 6A 2x 0,47mH 3nF 0,047µF PCB 6EEA2 6A 2x 0,47mH 3nF 0,009µF90° Faston 6EEB2 6A 2x 0,47mH 3nF 0,047µF90° Faston 6EAS1 6A 2x 0,47mH 3nF 0,009µF Faston 6EBS1 6A 2x 0,47mH 3nF 0,047µF Faston/snap-in 10EEA1 10A 2x 0,36mH 3nF 0,009µF Faston 10EEB1 10A 2x 0,36mH 3nF 0,047µF Faston 10EEAP 10A 2x 0,36mH 3nF 0,009µF PCB 10EEBP 10A 2x 0,36mH 3nF 0,047µF PCB 10EEA2 10A 2x 0,36mH 3nF 0,009µF90° Faston 10EEB2 10A 2x 0,36mH 3nF 0,047µF90° Faston 10EAS1 10A 2x 0,36mH 3nF 0,009µF Faston 10EBS1 10A 2x 0,36mH 3nF 0,047µF Faston/snap-in Max. leakage current line to ground 0.5 mA at 250 VAC/50 Hz For medical Applications Type Max.current Inductance Capacity Type Max.current Inductance Capacity UL/VDE C UL/VDE C X X 1EAH1 1A 2x 10mH 0,009µF 1EBH1 1A 2x 10mH 0,047µF 3EAH1 3A 2x 1,5mH 0,009µF 3EBH1 3A 2x 1,5mH 0,047µF 6EAH1 6A 2x 0,47mH 0,009µF 6EBH1 6A 2x 0,47mH 0,047µF 10EAH1 10A 2x 0,36mH 0,009µF 10EBH1 10A 2x 0,36mH 0,047µF Max. leakage current line to ground 5 µA at 250 VAC/50 Hz Electrical Schematic EEA / EEB / EAS / EBS EAH / EBH Power line Device Power line Device All specifications subject to change. Consult Tyco Electronics for latest design specifications. 31 Typ. Insertion Loss asym. sym. dB dB dB 90 90 90 80 80 80 70 70 70 60 60 60 50 50 50 40 40 40 30 30 30 20 20 20 10 10 10 0 0 0 0,1 1 10 30 0,1 1 10 30 0,1 1 10 30 1EEA Frequency in MHz Frequency in MHz 6EEA 3EEA Frequency in MHz dB dB dB 90 90 90 80 80 80 70 70 70 60 60 60 50 50 50 40 40 40 30 30 30 20 20 20 10 10 10 0 0 0 0,1 1 10 30 0,1 1 10 30 0,1 1 10 30 Frequency in MHz 10EEA 3EEB Frequency in MHz 1EEB Frequency in MHz dB dB dB 90 90 90 80 80 80 70 70 70 60 60 60 50 50 50 40 40 40 30 30 30 20 20 20 10 10 10 0 0 0 0,1 1 10 30 0,1 1 10 30 0,1 1 10 30 Frequency in MHz 6EEB Frequency in MHz 10EEB Frequency in MHz 1EAH dB dB dB 90 90 90 80 80 80 70 70 70 60 60 60 50 50 50 40 40 40 30 30 30 20 20 20 10 10 10 0 0 0 0,1 1 10 30 0,1 1 10 30 0,1 1 10 30 Frequency in MHz 3EAH 6EAH Frequency in MHz 10EAH Frequency in MHz dB dB dB 90 90 90 80 80 80 70 70 70 60 60 60 50 50 50 40 40 40 30 30 30 20 20 20 10 10 10 0 0 0 0,1 1 10 30 0,1 1 10 30 0,1 1 10 30 1EBH Frequency in MHz 3EBH1 Frequency in MHz Frequency in MHz 6EBH1 dB 90 80 70 60 50 40 30 20 10 0 0,1 1 10 30 10EBH1 Frequency in MHz 32 All specifications subject to change. Consult Tyco Electronics for latest design specifications. Case Styles and typ. Sizes EEA / EEB / EAH 3,4 Dia Panel cutout for front mounting 20,8 28,2 40,0 ±0,4 50,3 3,6 Dia 28,5 ±0,2 3,0 R 53,8 40,0 ±0,5 6,6 Dia 20,6 Panel cutout for back mounting 6,35 Faston 22,9 Hole 1,8 Dia Mounting holes 3,4 Dia Tolerance ±0,1 3,6 Dia 30,5 ±0,2 5,9 R 40,0 ±0,5 EEAP / EEBP for PLB 1,8 Dia 20,6 13,2 9,7 14 17,4±0,5 28,2 40,0 ±0,3 14,0 50,3 39,2 Order information: EAS / EBS snap-in mounting for thickness 0,8 – 1,2 mm: F-7533F for thickness 1,3 – 2,0 mm: F-7533B 32,0 35,8 11,5 +0,5 7,4 22,9 20,7 27,9 20,6 max +0,5 4,8 R 30,1 54,6 ±0,3 EEA2 / EEB2 20,6 Accessories for EEA / EEB / EAH / EBH / EAS / EBS -Series 12,7 10,5 Dia 39,2 40,1 ±0,3 6,9 Dia 50,3 Shroud for all versions 3 35,4 Material UL-94 Part No. 19,5 29,7 41-3151-AO 28,2 All specifications subject to change. Consult Tyco Electronics for latest design specifications. 33 V D E for EF1F and EF2F Series IEC Connector Filters EF-Series - FC-version with ground line according IEC 950 inductor Type Max.current Inductance Capacity Mounting Type Max.Current Inductance Capacity Mounting UL/VDEC C terminals UL/VDEC C terminals X Y X Y 1EF1 1A 2x1,8mH 0,009µF 2x2,8nFSolder lugs 1EF2 1A 2x1,8mH 0,009µF 2x2,8nFSolder lugs 1EF4 1A 2x1,8mH 0,009µF 2x2,8nFWire 1EF8 1A 2x1,8mH 0,009µF 2x2,8nFWire 3EF1 3A 2x0,99mH 0,009µF 2x2,8nFSolder lugs 3EF2 3A 2x0,99mH 0,009µF 2x2,8nFSolder lugs 3EF4 3A 2x0,99mH 0,009µF 2x2,8nFWire 3EF8 3A 2x0,99mH 0,009µF 2x2,8nFWire 6EF1 6A2x0,46mH 0,009µF 2x2,8nFSolder lugs 6EF2 6A2x0,46mH 0,009µF 2x2,8nFSolder lugs 6EF4 6A2x0,46mH 0,009µF 2x2,8nFWire 6EF8 6A2x0,46mH 0,009µF 2x2,8nFWire 1EF1F 1A 2x1,8mH 0,009µF 2x2,8nFFaston 1EF2F 1A 2x1,8mH 0,009µF 2x2,8nFFaston 3EF1F 3A 2x0,99mH 0,009µF 2x2,8nFFaston 3EF2F 3A 2x0,99mH 0,009µF 2x2,8nFFaston 6EF1F 6A2x0,46mH 0,009µF 2x2,8nFFaston 6EF2F 6A2x0,46mH 0,009µF 2x2,8nFFaston 10EF1F 10A2x0.36mH 0,009µF 2x2,8nFFaston 10EF1FC 10A2x0,36mH 0,009µF 2x2,8nFFaston Max. leakage current line to ground 0.5 mA at 250 VAC/50 Hz Electrical Schematic EF1 / EF2 / EF1F / EF2F EF1FC Power line Device Power line Device Typ. Insertion Loss in dB asym. sym. dB dB 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 10 0 0 0,11 10 30 0,11 10 30 Frequency in MHz 1EF Frequency in MHz 3EF dB dB 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 10 0 0 0,11 10 30 0,11 10 30 Frequency in MHz Frequency in MHz 6EF 10EF All specifications subject to change. Consult Tyco Electronics for latest design specifications. 34 Case Styles and typ. Sizes EF1 EF4 Mounting holes 3,4 Dia 20,8 20,6 50,6 40,0±0,4 Solder lugs 30,1 39,4 2 Dia 50,3 30,2 F 7,5 EF1F F 20,6 50,6 30,1 10A Version 66,5 40,0±0,4 50,3 EF8 Mounting holes F EF2 Blue 3,4 Dia 7,5 Green/Yellow 30,2 Brown 21,6 F 10,7 39,4 40,0±0,4 39,4 30,1 50,3 Solder lugs 2,0 Dia 20,8 Typical wire length 100 mm EF2F 21,6 16,5 40,0±0,4 39,4 30,1 50,3 Panel cutout for back mounting 22,9 3,6 Dia 30,5 5,9 R 40,0 Accessories for EF-Series 10,5 Dia Shroud 6,9 Dia for front mounting for all versions 20,8 EF1 / EF1F 3 3,6 Dia Material UL-94 30,5 35,4 1,6 R 40,0 Part No. Faston 6,35 29,7 19,5 41-3151-AO Hole 1,8 Dia Mounting holes 3,4 Dia Tolerance ± 0,1 All specifications subject to change. Consult Tyco Electronics for latest design specifications. 35 Brown Green/Yellow Blue IEC Connector Filters V D E ED-Series - 6ED1C/10ED1C with ground line inductor according IEC 950 - F-3550 high performance filter for switching power supplies F-3550 only approved Type Max.current Inductance Capacity Ground line Type Max.current Inductance Capacity Ground line UL/VDEC C inductor UL/VDEC C inductor X Y X Y 1ED1 1A 2x3,7mH 0,1µF 2x3nFNo 1ED2 1A 2x3,7mH 0,1µF 2x3nFNo 1ED4 1A 2x3,7mH 0,1µF 2x3nFNo 1ED8 1A 2x3,7mH 0,1µF 2x3nFNo 3ED1 3A 2x2,0mH 0,1µF 2x3nFNo 3ED2 3A 2x2,0mH 0,1µF 2x3nFNo 3ED4 3A 2x2,0mH 0,1µF 2x3nFNo 3ED8 3A 2x2,0mH 0,1µF 2x3nFNo 6ED1 6A2x0,93mH 0,1µF 2x3nFNo 6ED1C 6A2x0,93mH 0,1µF 2x3nFYes 6ED2 6A2x0,93mH 0,1µF 2x3nFNo 6ED4 6A2x0,93mH 0,1µF 2x3nFNo 6ED4C 6A2x0,93mH 0,1µF 2x3nHYes 6ED8 6A2x0,93mH 0,1µF 2x3nFNo 6ED8C 6A2x0,93mH 0,1µF 2x3nHYes 10ED1C 10A2x0,36mH 0,1µF 2x3nFYes 10ED1 10A2x0,36mH 0,1µF 2x3nFNo F-3550 3A 2x7mH 0,1µF 2x4nFNo Max. leakage current line to ground 0.5 mA at 250 VAC/50 Hz Electrical Schematic ED F-3550 Device Device Power line Power line 6ED1C / 10ED1C Device Power line Typ. Insertion Loss asym. sym. dB dB dB 90 90 90 80 80 80 70 70 70 60 60 60 50 50 50 40 40 40 30 30 30 20 20 20 10 10 10 0 0 0 0,1 110 100 0,11 10 30 0,11 10 100 Frequency in MHz 1ED Frequency in MHz 6ED Frequency in MHz 3ED dB dB dB 90 90 90 80 80 80 70 70 70 60 60 60 50 50 50 40 40 40 30 30 30 20 20 20 10 10 10 0 0 0 0,11 10 30 0,11 10 30 0,01 0,11 10 30 Frequency in MHz 6ED1C Frequency in MHz Frequency in MHz 10ED/10ED1C F3550 All specifications subject to change. Consult Tyco Electronics for latest design specifications. 36 Case Styles and typ. Sizes ED1 20,8 20,6 3,6 Dia Faston 6,35 55,9 30,1 30,5 Hole 1,8 Dia 10ED1 40,0 40,0±0,4 Mounting holes 3,4 Dia 1,6 R 6/10ED1C Tolerance±0,1 66,5 Panel cutout for front mounting 50,3 ED2 21,6 22,9 3,6 Dia 15,9 30,5 5,9 R 40,0±0,4 30,1 40,0 39,4 50,3 Faston 6,35 Mounting holes 3,4 Dia Panel cutout for back mounting Hole 1,8 Dia Tolerance±0,1 ED4 / ED4C F-3550 3,6±0,2 Dia Thread M3 20,8 Brown Green/Yellow 50 30,1 30 Blue ED4 39,4 ED4C 50,4 30,2 F 22,6 67,1 100 ±3,0 7,5 5 AWG18 15 40 Typical wire length 100 mm 20,5 F ED8 / ED8C Accessories for ED-Series F Blue 7,5 10,5 Dia Shroud Green/Yellow 6,9 Dia 30,2 Brown for all versions ED1 / ED1C F 3 Material UL-94 35,4 ED8 39,4 ED8C 50,4 Part No. 41-3151-AO 19,5 29,7 20,8 All specifications subject to change. Consult Tyco Electronics for latest design specifications. 37 Brown Green/Yellow Blue V D E IEC Connectors Filters EC-Series Like ED-Series, additionally according IEC 950 equipped with a second X-capacitor for increased symmetrical attenuation Type Max.current Inductance Capacity Type Max.current Inductance Capacity UL/VDEC C UL/VDEC C X Y X Y 1EC1 1A 2x3,7mH 2x0,1µF 2x3nF 1EC2 1A 2x3,7mH 2x0,1µF 2x3nF 1EC4 1A 2x3,7mH 2x0,1µF 2x3nF 1EC8 1A 2x3,7mH 2x0,1µF 2x3nF 3EC1 3A 2x2,0mH 2x0,1µF 2x3nF 3EC2 3A 2x2,0mH 2x0,1µF 2x3nF 3EC4 3A 2x2,0mH 2x0,1µF 2x3nF 3EC8 3A 2x2,0mH 2x0,1µF 2x3nF 6EC1 6A2x0,93mH 2x0,1µF 2x3nF 6EC2 6A2x0,93mH 2x0,1µF 2x3nF 6EC4 6A2x0,93mH 2x0,1µF 2x3nF 6EC8 6A2x0,93mH 2x0,1µF 2x3nF 10EC1 10A2x0,36mH 2x0,1µF 2x3nF Max. leakage current line to ground 0.5 mA at 250 VAC/50 Hz Electrical Schematic Power line Device Typ. Insertion Loss asym. sym. dB dB 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 10 0 0 0,11 10 30 0,11 10 30 Frequency in MHz Frequency in MHz 1EC 3EC dB dB 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 10 0 0 0,11 10 30 0,11 10 30 Frequency in MHz Frequency in MHz 6EC 10EC1 All specifications subject to change. Consult Tyco Electronics for latest design specifications. 38 Case Styles and typ. Sizes EC1 20,8 20,6 3,6 Dia Faston 6,35 66,5 30,1 30,5 Hole 1,8 Dia 40,0 40,0±0,4 Mounting holes 3,4 Dia 1,6 R Tolerance±0,1 50,3 Panel cutout for front mounting EC2 21,6 22,9 3,6 Dia 15,9 30,5 5,9 R 40,0±0,4 40,0 50,0 30,1 50,3 Mounting holes 3,4 Dia Panel cutout for back mounting Faston 6,4 Tolerance±0,1 Hole 1,8 Dia EC4 20,8 50,0 30,2 F Accessories for EC-Series 7,5 10,5 Dia 6,9 Dia Shroud Typical wire length 100 mm F for all versions 3 with EC1 35,4 EC8 Material UL-94 Part No. 19,5 29,7 F 41-3151-AO Blue 7,5 Green/Yellow 30,2 Brown F 50,0 20,8 All specifications subject to change. Consult Tyco Electronics for latest design specifications. 39 Brown Green/Yellow Blue V D E IEC Connector Filters Chassis-mount according IEC 950 EH-Series - For medical applications (UL 544) - Type 10EH4C with ground line inductor Type Max.current Inductance Capacity UL/VDEC C X Y 3EH1 3A 2x1,00mH 0,01µF– 3EH3 3A 2x1,00mH 0,01µF– 6EH1 6A2x0,46mH 0,01µF– 6EH3 6A2x0,46mH 0,01µF– 6EH4 6A2x0,46mH 0,01µF– 6EH5 6A2x0,46mH 0,01µF– 6EH8 6A2x0,46mH 0,01µF– 6EH9 6A2x0,46mH 0,01µF– 10EH1 10A2x0,36mH 0,01µF– 10EH3 10A2x0,36mH 0,01µF– 10EH4 10A2x0,36mH 0,01µF– 10EH4C 10A2x0,36mH 0,01µF– Max. leakage current line to ground 5 µA at 250 VAC/50 Hz Electrical Schematic 6EH 10EH4C Power line Device Device Power line Typ. Insertion Loss asym. dB dB 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 10 0 0 0,11 10 30 0,11 10 30 Frequency in MHz 6EH Frequency in MHz 10EH/10EH4C Case Styles and typ. Sizes 6EH4/10EH4 (C) 20.6 20.8 3.6 Dia Flat connectors 6.35 55.9 30.1 30.5 Hole 1.8 Dia 40.0 40.0±0.4 Mounting holes 3.4 Dia 1.6 R Tolerance±0.13 50.3 Panel cutout for front mounting All specifications subject to change. Consult Tyco Electronics for latest design specifications. 40 Case Styles and typ. Sizes 6EH5 6EH8 F 21.6 Blue 7.5 Green/Yellow 30.2 Brown F 39.4 30.2 39.4 F 7.5 21.6 Typical wire length 100 mm F 6EH9 22.9 21,6 3.6 Dia 15,9 30.5 5.9 R 40.0±0.4 39.4 40.0 Faston 6,35 Mounting holes 3,4 Dia 30.1 Panel cutout for back mounting 50.3 Hole 1,8 Dia Tolerance ±0,13 EH1 EH3 54,0 64,3 46,1 46.1 ±0,4 64.3 54±0.4 16.7 24.4 16,7 57,2 Accessories for EH-Series Shroud 10,5 Dia 6,9 Dia for all versions 6EH4 10EH4 3 10EH4C 35,4 Material UL-94 Part No. 29,7 19,5 41-3151-AO All specifications subject to change. Consult Tyco Electronics for latest design specifications. 41 Brown Green/Yellow Blue V D E PCB Filters XP-, YP-, ZP-Series - Compact housing - For various applications Electrical Schematic Type Max.current Inductance Capacity UL/VDEC C X Y 3EXP 3A/2A 2x2,3mH 0,27+0,1µF 2x4nF 4EXP 4A 2x2,2mH 0,33+0,1µF 2x4nF 6EXP 6A2x2,4mH 0,33+0,1µF 2x4nF 2EYP 2A/1,5A2x5,7mH 0,27+0,1µF 2x4nF Power line Device 3EYP 3A/2A 2x9,6mH 0,27+0,1µF 2x4nF 4EYP 4A 2x4,7mH 0,33+0,1µF 2x4nF 1EZP 1A/0,75A2x21,2mH 2x0,27µF 2x4nF 2EZP 2A/1,5A2x21,5mH 0,27+0,33µF 2x4nF 3EZP 3A/2A 2x13,77mH 0,47+0,27µF 2x4nF Max. leakage current line to ground 0.5 mA at 250 VAC/50 Hz X-Series - Normal attenuation Y-Series - Increased attenuation Z-Series - Very high attenuation Example: RFI suppression in electronic devices Example: RFI suppression in electronic devices Example: RFI suppression in electronic devices acc. to FCC Part 15J, Class B. also equipped with switching power supplies acc. also equipped with switching power supplies acc. to VDE 0871, Class A or FCC Part 15 J, Class B to VDE 0871, Class B. Typ. Insertion Loss asym. sym. dB dB dB 90 90 90 80 80 80 70 70 70 60 60 60 50 50 50 40 40 40 30 30 30 20 20 20 10 10 10 0 0 0 0,01 0,11 10 30 0,01 0,11 10 30 0,01 0,11 10 30 Frequency in MHz Frequency in MHz 6EXP 3EXP 4EXP Frequency in MHz dB dB dB 90 90 90 80 80 80 70 70 70 60 60 60 50 50 50 40 40 40 30 30 30 20 20 20 10 10 10 0 0 0 0,01 0,11 10 30 0,01 0,11 10 30 0,01 0,11 10 30 Frequency in MHz Frequency in MHz Frequency in MHz 2EYP 3EYP 4EYP dB dB dB 90 90 90 80 80 80 70 70 70 60 60 60 50 50 50 40 40 40 30 30 30 20 20 20 10 10 10 0 0 0 0,01 0,11 10 30 0,01 0,11 10 30 0,01 0,11 10 30 Frequency in MHz Frequency in MHz Frequency in MHz 1EZP 2EZP 3EZP All specifications subject to change. Consult Tyco Electronics for latest design specifications. 42 Case Styles and typ. Sizes 66,2 66,2 6EXP, 3EYP 3EXP, 4EXP 4EYP, 2EZP 2EYP, 1EZP 3EZP 41,2 44,5 3,3 3,3 67,6 5,2 15,4 47,0 Pin-size 1,27 x 1,27 6,2 26,7 Power line Device 28,1 8,9 30,2 Ground 17,8 3,8 6,2 Tolerance 0,15 Hole 1,9 Dia PCB Filters for various requirements - Applications: gambling machines, ATMs, office appliances. - For higher requirements Type Max.current Inductance Capacity Max. leakage current VDEC C line to ground X Y F-3443 3A 2x2mH 0,1µF 2x3nF 0,50mA Ground line inductance Case Styles and typ. Sizes Electrical Schematic 31 20.5 Power line Device Power line 46 Typ. Insertion Loss in dB asym. sym. Device dB 9.3 90 0.7 80 70 7 60 50 Mounting holes 1.0 min 5 40 Tolerance±0.15 30 17.5 20 10 0 0,01 0,11 10 30 15 Frequency in MHz F-3443 All specifications subject to change. Consult Tyco Electronics for latest design specifications. 43 V D E for EDP- and EOP-Series PCB Filters for various Requirements according IEC 950 EBP-, EDP-, EOP-Series - Applications: gambling machines, ATMs, office appliances - Compact housing and best price/ performance ratio for normal requirements Case Styles and typ. Sizes Type Max.current Inductance Capacity Max. leakage current Dimensions VDEC C line to ground A X Y 25.0 EBP A 4.5 Line 1EBP 1A 2x10,0 mH 0,047 µF 2,2 nF 0,50 mA25,0 3EBP 3A 2x2,0 mH 0,047 µF 2,2 nF 0,50 mA25,0 1EDP 1A 2x10,0 mH 0,1 µF 3nF 0,50 mA24,0 25.0 20.0 3EDP 3A 2x2,0 mH 0,1 µF 3nF 0,50 mA24,0 10.0 0.6x0.6 6EDP 6A2x0,93 mH 0,1 µF 3nF 0,50 mA24,0 10EDP 10A2x0,36 mH 0,1 µF 3nF 0,50 mA24,0 Load 1EOP 1A 2x10,0 mH 0,02 µF 3nF 0,50 mA19,5 2.5 15.0 2.5 Hole 1,2mm Dia 3EOP 3A 2x2,0 mH 0,02 µF 3nF 0,50 mA19,5 6EOP 6A2x0,93 mH 0,02 µF 3nF 0,50 mA19,5 10EOP 10A2x0,36 mH 0,02 µF 3nF 0,50 mA19,5 EDP/ EOP A Typ.Insertion Loss in dB asym. sym. Electrical Schematic dB 4.5 80 EBP 36.5 C Y 70 C X Power line Device 60 C Y 50 7.5±0.2 40 31.5 15±0.2 30 C EDP/EOP Y 20 7.9±0.5 Power line Device 10 C X C Y 17.5±0,2 0 0,11 10 30 9.1±0.5 Frequency in MHz 1EBP dB dB dB 80 80 80 70 70 70 60 60 60 50 50 50 40 40 40 30 30 30 20 20 20 10 10 10 0 0 0 0,11 10 30 0,1 110 30 0,11 10 30 Frequency in MHz 1EDP Frequency in MHz Frequency in MHz 3EDP 3EBP dB dB dB 80 80 80 70 70 70 60 60 60 50 50 50 40 40 40 30 30 30 20 20 20 10 10 10 0 0 0 0,11 10 30 0,1 110 30 0,11 10 30 Frequency in MHz 10EDP Frequency in MHz Frequency in MHz 1EOP 6EDP dB dB dB 80 80 80 70 70 70 60 60 60 50 50 50 40 40 40 30 30 30 20 20 20 10 10 10 0 0 0 0,11 10 30 0,1 110 30 0,1 110 30 Frequency in MHz Frequency in MHz 10EOP Frequency in MHz 6EOP 3EOP All specifications subject to change. Consult Tyco Electronics for latest design specifications. 44 V D E Chassis-mount Filters G/N-Series according IEC 950 For increased requirements - For applications in switching power supplies with switching frequencies from 20/50 to 150 kHz - Suitable for frequency converter applications (motor drives etc.) Type Max.current Inductance Capacity Max. leakage current (line to ground) UL/VDE L L C C at 250VAC / 50Hz 1 2 X Y 6EG1 6A/5A2x4,6mH 0,47µF+0,1µF 4nF 0,50mA 6VG1 6A/5A2x4,0mH 0,47µF+0,1µF 15nF 2,10mA 6VN1 6A/5A2x5,4mH 0,68µF+0,27µF 15nF 2,10mA 10EG1 10A/8A2x7,83mH 0,036mH 0,47µF+0,27µF 2+2nF 0,60mA 10VG1 10A/8A2x7,14mH 0,036mH 0,47µF+0,27µF 10+5,5nF 2,50mA 10VN1 10A/8A2x7,83mH 0,036mH 0,68µF+0,47µF 10+5,5nF 2,50mA Electrical Schematic 10A version 6A version C C C Y Y Y L 2 Power line Power line Device L Device L L 1 1 1 C C C Y Y Y Case Styles and typ. Sizes 6EG1 / 6VG1 / 6VN1 10EG1 / 10VG1 / 10VN1 103.2±0.4 74.6±0.4 6EG1/6VG1 39.6 6VN1 45.9 max 54.6 57.7 10A version: 45.7 113.5 85.8 Faston 6.35 (5) Hole 1,8 Dia 119.1 90.4 Mounting holes 4.8 Dia (2) Typ. Insertion Loss asym. sym. dB dB dB 90 90 90 80 80 80 70 70 70 60 60 60 50 50 50 40 40 40 30 30 30 20 20 20 10 10 10 0 0 0 0,01 0,11 10 30 0,01 0,11 10 30 0,01 0,11 10 30 Frequency in MHz Frequency in MHz Frequency in MHz 6EG 10VG1 10VN1 dB dB dB 90 90 90 80 80 80 70 70 70 60 60 60 50 50 50 40 40 40 30 30 30 20 20 20 10 10 10 0 0 0 0,01 0,11 10 30 0,01 0,11 10 30 0,01 0,11 10 30 Frequency in MHz Frequency in MHz Frequency in MHz 6VG1 6VN1 10EG1 All specifications subject to change. Consult Tyco Electronics for latest design specifications. 45 V D E Universal Chassis- mount Filters according IEC 950 B-Series Designed to clean-up noise in a wide range of electrical and electronical devices (VB, EB) Type Max. leak- Capacity Type Max. leak- Capacity Max. current Inductance Dimensions (mm) age current C age current C UL/VDEA B C D E Y Y 1EB1 2x2,8nF 1VB1 2x5,5nF 1A 2x1,8mH 57,146,116,7 54,0 64,2 1EB3 2x2,8nF 1VB3 2x5,5nF 1A 2x1,8mH 24,346,116,7 54,0 64,2 2EB1 Line 2x2,8nF 2VB1 Line 2x5,5nF 2A 2x0,54mH 57,146,116,7 54,0 64,2 2EB3 to 2x2,8nF 2VB3 to 2x5,5nF 2A 2x0,54mH 24,346,116,7 54,0 64,2 3EB1 ground 2x2,8nF 3VB1 ground 2x5,5nF 3A 2x1,7mH 66,146,119,9 54,0 64,2 3EB3 2x2,8nF 3VB3 2x5,5nF 3A 2x1,7mH 33,246,119,9 54,0 64,2 5EB1 2x2,8nF 5VB1 2x5,5nF5A2x0,51mH 66,146,119,9 54,0 64,2 5EB3 250VAC 2x2,8nF 5VB3 250VAC 2x5,5nF5A2x0,51mH 33,246,119,9 54,0 64,2 10EB1 50Hz 2x2,8nF 10VB1 50Hz 2x5,5nF 10A/8A2x0,49mH 66,146,129,4 54,0 64,2 10EB3 3x2,8nF 10VB3 2x5,5nF 10A/8A2x0,49mH 33,446,129,4 54,0 64,2 20EB1 0,40mA2x2,8nF 10VB6 1,0mA2x5,5nF 10A/8A2x0,49mH 69,146,129,4 54,0 64,2 20VB1 2x5,5nF 20A/16A2x0,44mH 85,2 52,429,4 60,3 71,3 20VB6 2x5,5nF 20A/16A2x0,44mH 87,9 52,429,4 60,3 71,3 30VB6 2x5,5nF 30A/25A2x0,69mH 135,6 85,7 38,9 95,3106,7 Electrical Schematic Power line Device C = 0,009 µF X Typ. Insertion Loss asym. sym. dB dB dB 90 90 90 80 80 80 70 70 70 60 60 60 50 50 50 40 40 40 30 30 30 20 20 20 10 10 10 0 0 0 0,11 10 30 0,11 10 30 0,11 10 30 Frequency in MHz Frequency in MHz 2EB/5EB/10EB Frequency in MHz 20EB 1EB/3EB dB dB dB 90 90 90 80 80 80 70 70 70 60 60 60 50 50 50 40 40 40 30 30 30 20 20 20 10 10 10 0 0 0 0,11 10 30 0,11 10 30 0,11 10 30 Frequency in MHz Frequency in MHz 3VB Frequency in MHz 2VB 1VB All specifications subject to change. Consult Tyco Electronics for latest design specifications. 46 Case Styles and typ. Sizes B1 10B6 / 20B6 Terminal bolt and nut No. 8-32 E E DB DB AC C A Mounting holes 4,8 Dia Faston 6,35Hole 1,8 Dia Mounting holes 4,8 Dia B3 Blue Blue Wire length 100 min. Green/Yellow E DB Brown Brown Mounting holes 4,8 Dia A C 30B6 Terminal bolt Slot 6,4 x 4 and nut No. 8-32 E DB 50.8 A C Typ. Insertion Loss asym. sym. dB dB dB dB 90 90 90 90 80 80 80 80 70 70 70 70 60 60 60 60 50 50 50 50 40 40 40 40 30 30 30 30 20 20 20 20 10 10 10 10 0 0 0 0 0,11 10 30 0,11 10 30 0,11 10 30 0,11 10 30 5VB Frequency in MHz Frequency in MHz Frequency in MHz Frequency in MHz 20VB 30VB 10VB All specifications subject to change. Consult Tyco Electronics for latest design specifications. 47 V D E Chassis/Back Panel Mount Filters with/ according IEC 950 without IEC Connector K-Series - Comparable to B-Series, with increased symmetrical attentuation Type Max.leak- Capacity Type Max.leak- Capacity Max.current Inductance. Tapped Dimensions (mm) age current C age current C UL/VDE insert A B C D E Y Y 1EK1 2x2,8nF 1VK1 2x5,5nF 1A 2x1,8mH 78,7 52,423,1 60,3 71,3 1EK3 2x2,8nF 1VK3 2x5,5nF 1A 2x1,8mH 45,9 52,423,1 60,3 71,3 2EK1 2x2,8nF 2VK1 2x5,5nF 2A 2x0,54mH 78,7 52,423,1 60,3 71,3 2EK3 2x2,8nF 2VK3 2x5,5nF 2A 2x0,54mH 45,9 52,423,1 60,3 71,3 3EK1 2x2,8nF 3VK1 2x5,5nF 3A 2x1,7mH 78,7 52,429,4 60,3 71,3 3EK3 Line 2x2,8nF 3VK3 Line 2x5,5nF 3A 2x1,7mH 45,9 52,429,4 60,3 71,3 3EK7 to 2x2,8nF 3VK7 to 2x5,5nF 3A 2x1,7mH 6-32x1/4 81,4 57,132,440,0 16,0 3EK7M ground 2x2,8nF 3VK7M ground 2x5,5nF 3A 2x1,7mH M 3x0,5 81,4 57,132,440,0 16,0 5EK1 2x2,8nF 5VK1 2x5x5nF5A2x0,51mH 78,7 52,429,4 60,3 71,3 5EK3 250VAC 2x2,8nF 5VK3 250VAC 2x5,5nF5A2x0,51mH 45,9 52,429,4 60,3 71,3 5EK7 50Hz 2x2,8nF 5VK7 50Hz 2x5,5nF5A2x0,51mH 6-32x1/4 81,4 57,132,440,0 16,0 5EK7M 2x2,8nF 5VK7M 2x5,5nF5A2x0,51mH M 3x0,5 81,4 57,132,440,0 16,0 10EK1 2x2,8nF 10VK1 2x5,5nF 10A/8A2x0,49mH 85,1 52,429,4 60,3 71,3 10EK3 0,40mA2x2,8nF 10VK3 1,0mA2x5,5nF 10A/8A2x0,49mH 52,4 52,429,4 60,3 71,3 10VK6 2x5,5nF 10A/8A2x0,49mH 87,9 52,429,4 60,316,0 10EK7 2x2,8nF 10VK7 2x5,5nF 10A/8A2x0,49mH 6-32x1/4 94,1 57,144,440,0 16,0 10EK7M 2x2,8nF 10VK7M 2x5,5nF 10A/8A2x0,49mH M 3x0,5 94,1 57,144,440,0 16,0 20EK1 2x2,8nF 20VK1 2x5,5nF 20A/16A2x0,44mH 87,9 65,0 38,8 74,6 85,1 20VK6 2x5,5nF 20A/16A2x0,44mH 87,9 65,0 38,8 74,6 85,1 20VK7 2x5,5nF 20A/16A2x0,44mH 6-32x1/4 96,5 57,9 50,8 40,421,5 30VK6 2x5,5nF 30A/25A2x0,69mH 135,6 85,7 38,9 95,3106,7 30VK6C 2x5,5nF 30A/25A2x0,69mH 135,6 85,7 38,9 95,3106,7 Electrical Schematic 30VK6C (with choke) Power line Device Power line Device C = 2 x 0,1 µF except 30VK6: C = 2 x 0,27 µF + 0,47 µF X X Typ. Insertion Loss asym. sym. dB dB dB dB 90 90 90 90 80 80 80 80 70 70 70 70 60 60 60 60 50 50 50 50 40 40 40 40 30 30 30 30 20 20 20 20 10 10 10 10 0 0 0 0 0,11 10 30 0,11 10 30 0,11 10 30 0,11 10 30 Frequency in MHz Frequency in MHz 5EK Frequency in MHz 2EK/10EK Frequency in MHz 1EK/3EK 20EK All specifications subject to change. Consult Tyco Electronics for latest design specifications. 48 Case Styles and typ. Sizes K1 E Tapped insert K3 K7 / K7M E Blue Blue D Green/Yellow E DB B Brown Brown DB A A A C 6 R 4 Dia Wire length 100 min. Mounting holes 4,8 Dia 23.1 Faston 6,35Hole 1,8 Dia Mounting holes 4,8 Dia 32.9 Panel cutout for back mounting Tolerance±0,1, Faston 6.35, Hole 1,8 Dia 40.0 C 10K6 / 20K6 Terminal bolt and C nut No. 8-32 E DB 20VK7 E AC Mounting holes 4,8 Dia 30VK6/30VK6C DB Slot 6.4 x 4 Terminal bolt and nut No. 8-32 A C 1.6 R 4 Dia E DB 37.1 Insulated terminal on 29.1 30VK6C only 40.0 50.8 A C Typ. Insertion Loss asym. sym. dB dB dB dB 90 90 90 90 80 80 80 80 70 70 70 70 60 60 60 60 50 50 50 50 40 40 40 40 30 30 30 30 20 20 20 20 10 10 10 10 0 0 0 0 0,11 10 30 0,11 10 30 0,11 10 30 0,11 10 30 1VK Frequency in MHz 3VK Frequency in MHz Frequency in MHz Frequency in MHz 2VK 5VK dB dB dB dB 90 90 90 90 80 80 80 80 70 70 70 70 60 60 60 60 50 50 50 50 40 40 40 40 30 30 30 30 20 20 20 20 10 10 10 10 0 0 0 0 0,15 110 30 0,11 10 30 0,11 10 30 0,11 10 30 Frequency in MHz Frequency in MHz Frequency in MHz 30VK6C Frequency in MHz 20VK 30VK 10VK All specifications subject to change. Consult Tyco Electronics for latest design specifications. 49 V D E 6,5VR1 VDE only Chassis/Back Panel Approvals are not valid for C-models Mount Filters according IEC 950 with/without IEC Connector R-Series - Double tuned circuit filter for low impedance loads (motors, semiconductor actuators etc.) Type Max.leak- Capacity Type Max.leak- Capacity Max.current Inductance Tapped Dimensions (mm) age current C age current C UL/VDE L /L insert A B C D E Y Y 1 2 1ER1 2x2,8nF 1VR1 2x5,5nF 1A 2x1,8mH 85,145,9 29,4 60,3 70,6 1ER3 2x2,8nF 1VR3 2x5,5nF 1A 2x1,8mH 52,445,9 29,4 60,3 70,6 2ER1 2x2,8nF 2VR1 2x5,5nF 2A 2x0,54mH 85,145,9 29,4 60,3 70,6 2ER3 2x2,8nF 2VR3 2x5,5nF 2A 2x0,54mH 52,445,9 29,4 60,3 70,6 3ER1 2x2,8nF 3VR1 2x5,5nF 3A 2x1,7mH 97,7 52,429,4 74,6 85,1 3ER1C 2x2,8nF 3A 2x1,7mH 65,1 52,6 38,9 74,6 85,1 3ER3 Line 2x2,8nF 3VR3 Line 2x5,5nF 3A 2x1,7mH 65,0 52,429,4 74,6 85,1 3ER7 to 2x2,8nF 3VR7 to 2x5,5nF 3A 2x1,7mH 6-32x1/4110,0 57,132,440,0 16,3 3ER7M ground 2x2,8nF 3VR7M ground 2x5,5nF 3A 2x1,7mH M 3x0,5 110,0 57,132,440,0 16,3 5ER1 2x2,8nF 5VR1 2x5,5nF5A2x0,51mH 97,7 52,429,4 74,6 85,1 5ER3 2x2,8nF 5VR3 2x5,5nF5A2x0,51mH 65,0 52,429,4 74,6 85,1 5ER7 250VAC 2x2,8nF 5VR7 250VAC 2x5,5nF5A2x0,51mH 6-32x1/4110,0 57,132,440,0 16,3 5ER7M 50Hz 2x2,8nF 5VR7M 50Hz 2x5,5nF5A2x0,51mH M 3x0,5 110,0 57,132,440,0 16,3 6ER1C 2x2,8nF 6,5VR1 2x5,5nF 6,5A2x0,52mH 65,1 52,6 38,9 74,6 85,1 10ER1 2x2,8nF 10VR1 2x5,5nF 10A/8A2x0,49mH 97,7 52,438,8 74,6 85,1 10ER1C 2x2,8nF 10A/8A2x0,49mH 65,1 52,6 38,9 74,6 85,1 10ER3 0,40mA2x2,8nF 10VR3 1,0mA2x5,5nF 10A/8A2x0,49mH 65,0 52,438,8 74,6 85,1 10VR6 2x5,5nF 10A/8A2x0,49mH 100,6 52,438,8 74,6 85,1 10ER7 2x2,8nF 10VR7 2x5,5nF 10A/8A2x0,49mH 6-32x1/4110,0 57,138,8 40,0 22,3 10ER7M 2x2,8nF 10VR7M 2x5,5nF 10A/8A2x0,49mH M 3x0,5 110,0 57,138,8 40,0 22,3 20ER1 2x2,8nF 20VR1 2x5,5nF 20A/16A2x0,44mH 132,6 85,6 38,8 95,3106,7 20VR6 2x5,5nF 20A/16A2x0,44mH 135,6 85,6 38,8 95,3106,7 Electrical Schematic ER / VR ER1C 0,28 mH Power line Device Power line L L Device L L 1 2 1 2 C = 2 x 0,1 µF C = 3 x 0,1 µF X X Typ. Insertion Loss asym. sym. dB dB dB dB 90 90 90 90 80 80 80 80 70 70 70 70 60 60 60 60 50 50 50 50 40 40 40 40 30 30 30 30 20 20 20 20 10 10 10 10 0 0 0 0 0,11 10 30 0,11 10 30 0,11 10 30 0,11 10 30 1ER Frequency in MHz 2ER/10ER/20ER Frequency in MHz 3ER Frequency in MHz 5ER/6ERC Frequency in MHz All specifications subject to change. Consult Tyco Electronics for latest design specifications. 50 Case Styles and typ.Sizes R3 R1 (except 20A) Blue Blue B Brown Brown B Green A C Yellow D Wire length 100 min. E Mounting holes 4,8 Dia. D C E Faston 6,35 R7 / R7M Tapped insert Hole 1,8 Dia A Mounting holes 4,8 Dia Terminal bolt and D B 10VR6 nut No. 8-32 B A C D C 4 Dia Mounting 6R E holes 4,8 Dia A 23,1 30,9 E 15,9 R1C 40,0 D 12,7 Faston 6,35 Hole 1,8 Dia. Panel cutout for back mounting Tapped insert: Tolerance ±0,1 M = metric M3x0,5 Inch-thread 6-32x1/4 B 25,4 20VR6 Terminal bolt and Slot 6,4 x 4 nut No. 8-32 4,8 Dia A C 16,4 E DB 1,8 Dia Faston 6,3 (5) 50.8 Models 20VR1 and 20ER1 are the same as 20VR6, A C with Faston 6.35 instead of terminal bolts shown. Typ. Insertion Loss asym. sym. dB dB dB 90 90 90 80 80 80 70 70 70 60 60 60 50 50 50 40 40 40 30 30 30 20 20 20 10 10 10 0 0 0 0,11 10 30 0,11 10 30 0,11 10 30 Frequency in MHz 1VR Frequency in MHz 2VR 3VR Frequency in MHz dB dB dB 90 90 90 80 80 80 70 70 70 60 60 60 50 50 50 40 40 40 30 30 30 20 20 20 10 10 10 0 0 0 0,11 10 30 0,11 10 30 0,11 10 30 5VR/6,5VR Frequency in MHz 10VR Frequency in MHz 20VR Frequency in MHz All specifications subject to change. Consult Tyco Electronics for latest design specifications. 51 V D E Chassis/Back Panel Mount Filters with according IEC 950 IEC Connector DK-Series - Extended K-Series Type Max.leak- Capac. Type Max.leak- Capacity Max. current Inductance Dimensions (mm) age current C age current C C UL/VDEA B C D E Y x Y 1EDK1 3nF 1VDK1 0,54x0,27µF 4,7nF 1A/1A 2x 1,86mH 85,1 52,6 29,5 60,3 71,4 1EDK3 Line 3nF 1VDK3 Line 0,54x0,27µF 4,7nF 1A/1A 2x 1,86mH 52,6 52,6 29,5 60,3 71,4 3EDK1 to 3nF 3VDK1 to 2x0,54µF 5,5nF 3A/3A 2x 1,76mH 97,8 52,6 29,5 74,6 85,1 3EDK3 ground 3nF 3VDK3 ground 2x0,54µF 5,5nF 3A/3A 2x 1,76mH 65,0 52,6 29,5 74,6 85,1 6EDK1 3nF 6VDK1 2x0,54µF 5,5nF6A/6A2x 0,516mH 97,8 52.6 33,5 74,6 85,1 6EDK3 250VAC 3nF 6VDK3 250VAC 2x0,54µF 5,5nF6A/6A2x 0,516mH 65,0 52,6 29,5 74,6 85,1 10EDK1 50Hz 3nF 10VDK1 50Hz 2x0,54µF 5,5nF 10A/8A2x 0,495mH 97,8 52,6 33,5 74,6 85,1 10EDK3 3nF 10VDK3 2x0,54µF 5,5nF 10A/8A2x 0,495mH 65,3 52,6 33,5 74,6 85,1 20EDK1 0,50mA3nF 20VDK1 0,90mA2x0,54µF 5,5nF 20A/16A2x 0.540mH 97,8 52,6 45,2 74,6 85,1 20VDK6 2x0,54µF 5,5nF 20A/16A2x 0,540mH 87,9 52,6 45,2 74,6 85,1 Electrical Schematic C Y Power line Device C Y Typ. Insertion Loss asym. sym. dB dB 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 10 0 0 0,11 10 30 0,11 10 30 Frequency in MHz 1EDK/3EDK 6EDK/10EDK/20EDK Frequ. in MHz dB dB 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 10 0 0 0,11 10 30 0,11 10 30 1VDK/3VDK Frequency in MHz 6VDK/10VDK/20VDK Frequ. in MHz All specifications subject to change. Consult Tyco Electronics for latest design specifications. 52 Case Styles and typ. Sizes VDK1 / EDK1 20VDK1 / 20EDK1 E C D B E D B C A Faston 6,35 (5) Hole 1,8 Dia. A Mounting holes 4,8 Dia (2) VDK3 / EDK3 20VDK6 E C D Blue Blue B E D B Brown Brown A A C Green/Yellow Terminal screws No. 8-32 (5x) Typical wire length 100 mm All specifications subject to change. Consult Tyco Electronics for latest design specifications. 53 V D E Chassis-mount Filter VS- VV-, VW-Series These series of similarly constructed according IEC 950 filters are available in various electronic designs, optimized for the respective impedance requirements (switching power supplies, thyristor circuits, motor drives etc.). Also for DC/DC applications. Type Max.current Inductance Capacity Comm.mode Normal mode Device impedance Dimensions (mm) UL/VDE L L C impedance impedance at high frequencies A B C D E 1 2 X 3VS1 3A/2,5A2x1mH 2x0,03mH 2x0,27µF 85,346,129,4 60,3 70,5 6VS1 6A/5A2x1,8mH 2x0,07mH 2x0,27µFN=2 N=3 High 98,0 52,8 38,9 74,6 84,8 10VS1 10A/8A2x1,2mH 2x0,04mH 2x0,27µF (‘L’) (‘Pi’) 98,0 52,8 38,9 74,6 84,8 20VS1 20A/16A2x0,93mH 2x0,03mH 2x0,27µF 132,8 85,7 38,9 95,3106,7 20VS6 20A/16A2x0,93mH 2x0,03mH 2x0,27µF 135,6 85,7 38,9 95,5 106,6 3VV1 3A/2,5A2x1mH 2x0,03mH 3x0,27µF 85,346,132,6 60,3 70,5 6VV1 6A/5A2x1,8mH 2x0,07mH 3x0,27µFN=3 N=3 Low 98,0 52,8 38,9 74,6 84,8 10VV1 10A/8A2x1,2mH 2x0,04mH 3x0,27µF(‘T’) (‘Pi’) 98,0 52,8 38,9 74,6 84.8 20VV1 20A/16A2x1,73mH 2x0,03mH 3x0,27µF 132,8 85,7 38,9 95,3106,7 20VV6 20A/16A2x1,73mH 2x0,03mH 3x0,27µF 135,6 85,7 38,9 95,5 106,6 3VW1 3A/2,5A2x1mH 2x0,03mH 3x0,27µF 85,346,132,6 60,3 70,5 6VW1 6A/5A2x1,8mH 2x0,07mH 3x0,27µFN=4 N=3 High 98,0 52,8 38,9 74,6 84,8 10VW1 10A/8A2x1,2mH 2x0,04mH 3x0,27µF (‘Dbl.L’) (‘Pi’) 98,0 52,8 38,9 74,6 84,8 20VW1 20A/16A2x1,73mH 2x0,03mH 3x0,27µF 132,8 85,7 38,9 95,3106,7 20VW6 20A/16A2x1,73mH 2x0,03mH 3x0,27µF 135,6 85,7 38,9 95,5 106,6 Max. leakage current line to ground 1.0 mA at 250 VAC/50 Hz, VS, VV; 1.5 mA VW For medical Applications Type Max.current Inductance Capacity Comm.mode Normal mode Device impedance Dimensions (mm) UL/VDE L L C impedance impedance at high frequencies A B C D E 1 2 X 3MV1 3A/2,5A2x1mH 2x0,04mH 3x0,27µF 85,346,132,6 60,3 70,5 6MV1 6A/5A2x1,8mH 2x0,07mH 3x0,27µFN=3 N=3 Low 98,0 52,8 38,9 74,6 84,8 10MV1 10A/8A2x1,2mH 2x0,05mH 3x0,27µF(‘T’) (‘Pi’) 98,0 52,8 38,9 74,6 84.8 20MV1 20A/16A2x1,73mH 2x0,03mH 2x0,47µF 132,8 85,7 38,9 95,3106,7 Max. leakage current line to ground 250 VAC/50 Hz 0,15 mA Electrical Schematic VS-Series VW-Series * * C C C Y Y Y Power line L Power line L 2 L L Device 1 Device 2 1 C C C Y Y Y * * CY = 5,5 nF CY = 3,2 nF * R only by 20A-device VV-Series MV-Series C C Y Y Power line Power line L L Device L L Device 1 1 2 2 C C Y Y CY = 5,5 nF CY = 1 nF All specifications subject to change. Consult Tyco Electronics for latest design specifications. 54 Case Styles and typ. Sizes 3A / 6A / 10A 20A Slot 6.4 x 4 Terminal bolt Slot 6,4 x 4,0 and nut No. 8-32 DB E E D B D E A Faston 6,4 50,8 50.8 B Slot 1,8 x 4 AC A C Faston 6,35 Slot 1,8 x 4,0 Mounting holes 4,8 Dia C Typ. Insertion Loss asym. sym. dB dB dB dB 90 90 90 90 80 80 80 80 70 70 70 70 60 60 60 60 50 50 50 50 40 40 40 40 30 30 30 30 20 20 20 20 10 10 10 10 0 0 0 0 0,11 10 30 0,11 10 30 0,11 10 30 0,11 10 30 3VS Frequency in MHz Frequency in MHz Frequency in MHz 6VS 10VS Frequency in MHz 20VS dB dB dB dB 90 90 90 90 80 80 80 80 70 70 70 70 60 60 60 60 50 50 50 50 40 40 40 40 30 30 30 30 20 20 20 20 10 10 10 10 0 0 0 0 0,1 110 30 0,11 10 30 0,11 10 30 0,11 10 30 Frequency in MHz 10VV Frequency in MHz 20VV 3VV 6VV Frequency in MHz Frequency in MHz dB dB dB dB 90 90 90 90 80 80 80 80 70 70 70 70 60 60 60 60 50 50 50 50 40 40 40 40 30 30 30 30 20 20 20 20 10 10 10 10 0 0 0 0 0,11 10 30 0,11 10 30 0,11 10 30 0,11 10 30 6VW Frequency in MHz Frequency in MHz 10VW 3VW Frequency in MHz 20VW Frequency in MHz dB dB dB dB 90 90 90 90 80 80 80 80 70 70 70 70 60 60 60 60 50 50 50 50 40 40 40 40 30 30 30 30 20 20 20 20 10 10 10 10 0 0 0 0 0,11 10 30 0,11 10 30 0,11 10 30 0,11 10 30 Frequency in MHz 20MV Frequency in MHz Frequency in MHz 6MV Frequency in MHz 10MV 3MV All specifications subject to change. Consult Tyco Electronics for latest design specifications. 55 V D E Chassis/Back Panel Mount Filters with/ according IEC 950 without IEC Connector SK-Series - Single stage filter with very high symmetrical and asymmetrical attenuation - Extended frequency range (effective above 10 kHz) Type Max.leak- Induc. Capacity Typ Max.leak- Induc. Capacity Max.Current Terminal Dimensions (mm) age current C age current C UL/VDEA B C D E Y Y 3ESK1 2x7mH 2x2,8nF 3VSK1 2x7mH 2x5,5nF 3A Faston 97,7 52,429,4 74,6 85,1 3ESK3 Line 2x7mH 2x2,8nF 3VSK3 Line 2x7mH 2x5,5nF 3A Wire 65,0 52,429,4 74,6 85,1 3ESK7 to 2x7mH 2x2,8nF 3VSK7 to 2x7mH 2x5,5nF 3A IEC-connector 81,5 57,138,8 40,0 16,0 3ESK7M ground 2x7mH 2x2,8nF 3VSK7M ground 2x7mH 2x5,5nF 3A IEC-connector 81,5 57,138,8 40,0 16,0 6ESK1 2x8,7mH 2x2,8nF 6VSK1 2x8,7mH 2x5,5nF6A/5A Faston 110,1 57,132,4 87,1 97,1 6ESK3 2x8,7mH 2x2,8nF 6VSK3 2x8,7mH 2x5,5nF6A/5A Wire 77,4 57,132,4 87,1 97,1 6ESK7 250VAC 2x8,7mH 2x2,8nF 6VSK7 250VAC 2x8,7mH 2x5,5nF6A/5A IEC-connector 81,5 57,145,140,0 16,0 6ESK7M 50Hz 2x8,7mH 2x2,8nF 6VSK7M 50Hz 2x8,7mH 2x5,5nF6A/5A IEC-connector 81,5 57,145,140,0 16,0 10ESK1 2x7mH 2x2,8nF 10VSK1 2x7mH 2x5,5nF 10A/8A Faston 126,2 57,145,1103,2 113,3 10ESK3 0,40mA2x7mH 2x2,8nF 10VSK3 1,0mA2x7mH 2x5,5nF 10A/8A Wire 93,6 57,145,1103,2 113,3 10ESK7 2x7mH 2x2,8nF 10VSK7 2x7mH 2x5,5nF 10A/8A IEC-connector 109,9 57,145,140,0 16,0 10ESK7M 2x7mH 2x2,8nF 10VSK7M 2x7mH 2x5,5nF 10A/8A IEC-connector 109,9 57,145,140,0 16,07 20ESK6 Line/ground 2x6,1 mH 2x4nF 20VSK6 Line/ground 2x6,1mH 2x10nF 20 A / 16 A Mounting stud 127,3 57,145,1103,2 113,3 30ESK6 250VAC 2x1,7mH 2x4nF 30VSK6 250VAC 2x1,7mH 2x10nF 30 A / 25 A Mounting stud 125,0 79,3 69,9 87,3101,6 30ESK6C 0,50mA2x1,7mH 2x4nF 30VSK6C 1,25mA2x1,7mH 2x10nF 30 A / 25 A Mounting stud 125,0 79,3 69,9 87,3101,6 40VSK6 1,25mA2x2,3mH 2x10nF 40 A / 36 A Mounting stud 152,4 79,3 55,4 88,9 100,6 Electrical Schematic Only 30ESK6C / 30VSK6C Device Device Power line Power line C C C C X X X X C = 0,27 µF except 30A=0,54µF, 40A=1µF X Typ. Insertion Loss asym. sym. dB dB 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 10 0 0 0,01 0,11 10 30 0,01 0,11 10 30 Frequency in MHz 3ESK/6ESK Frequency in MHz 3VSK/6VSK dB dB 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 10 0 0 0,01 0,11 10 30 0,01 0,11 10 30 Frequency in MHz 10ESK/20ESK 10VSK/20VSK Frequency in MHz All specifications subject to change. Consult Tyco Electronics for latest design specifications. 56 Case Styles and typ. Sizes 20ESK6 / 20VSK6 6SK3 / 10SK3 E Blue Blue D C Green/Yellow B Brown Brown B A C D E Terminal threads No 8-32 Wire length 100 min Mounting holes 4,8 Dia A 3SK3 Blue Blue 30ESK6 / 30VSK6 B Brown Brown B ED Green A Yellow C D E Terminal threads No 10-32 36,7 SK1 A C B 30ESK6C / 30VSK6C D C E Faston 6,35 E DB A Hole 1,8 x 4,0 Mounting holes 4,8 Dia Mounting slots 6,35 x 3,96 SK7 / SK7M Terminal threads No 10-32 38,7 SK7: Tapped insert No. 6-32x1/4 SK7M: M3x0,5 A C 40VSK6 DB Terminal bolt and nut No. 8-32 50,8 E A C E B D Panel cutout for back mounting 6R 4 Dia 23,1 A C 32,9 Faston 6,35 Mounting holes 5.2 x 4.0 40.0 Hole 1,8 Dia Typ. Insertion Loss asym. sym. dB dB 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 10 0 0 0,01 0,11 10 30 0,01 0,11 10 30 Frequency in MHz 30ESK 30VSK Frequency in MHz All specifications subject to change. Consult Tyco Electronics for latest design specifications. 57 V D E Chassis-mount Filters T-Series Applications, special features: according IEC 950 - Optimized filter with regard to attenuation and size - Very high symmetrical and asymmetrical attenuation - Low leakage currents - Especially suited for RFI suppression above 10 kHz - Suitable for motor drive applications - HT types for medical applications Type Max.current Max. leak- Capacity Inductance Capacity For medical Applications UL/VDE age current C L L C Y 1 2 X 3ET1 3A/2,75A2x4nF 2x36,8mH 2x0,47µF Type Max.current Max. leak- Inductance Capacity 3ET3 3A/2,75A Line 2x4nF 2x36,8mH 2x0,47µF UL/VDE age current L L C 1 2 X 3ET7 3A/2,75Ato 2x4nF 2x36,8mH 2x0,47µF 6ET1 6A/5A ground 2x4nF 2x18,5mH 2x0,47µF 3EHT1 3A/2,75A2x36,8mH 2x0,47µF 6ET3 6A/5A2x4nF 2x18,5mH 2x0,47µF 3EHT3 3A/2,75A Line 2x36,8mH 2x0,47µF 6ET7 6A/5A250VAC/ 2x4nF 2x18,5mH 2x0,47µF 3EHT7 3A/2,75Ato 2x36,8mH 2x0,47µF 10ET1 10A/8A 50Hz 2x4nF 2x9,5mH 0,074mH 1,77µF 6EHT1 6A/5A ground 2x18,5mH 2x0,47µF 10ET3 10A/8A2x4nF 2x9,5mH 0,074mH 1,77µF 6EHT3 6A/5A2x18,5mH 2x0,47µF 15ET1 15A/12A 0,5mA2x4nF 2x5,04mH 2x0,03mH 2,07µF 6EHT7 6A/5A250VAC/ 2x18,5mH 2x0,47µF 15ET6 15A/12A 2x4nF 2x5,04mH 2x0,03mH 2,07µF 10EHT1 10A/8A 50Hz 2x9,5mH 0,074mH 1,77µF 10VT1 10A/8A1,25mA2x10nF 2x9,5mH 0,074mH 1,77µF 10EHT3 10A/8A 5µA2x9,5mH 0,074mH 1,77µF 10VT3 10A/8A1,25mA2x10nF 2x9,5mH 0,074mH 1,77µF 15EHT1 15A/12A 2x5,04mH 2x0,03mH 2,07µF 15VT1 15A/12A 2,1mA2x15nF 2x5,04mH 2x0,03mH 2,07µF 15EHT6 15A/12A 2x5,04mH 2x0,03mH 2,07µF 15VT6 15A/12A 2,1mA2x15nF 2x5,04mH 2x0,03mH 2,07µF 20ET1/6 20A/20A 0,5mA2x4nF 2x3,88mH 2x0,03mH 2,07µF 20VT1/6 20A/20A2,1mA2x15nF 2x3,88mH 2x0,03mH 2,07µF Electrical Schematic 10ET & 10VT 3ET & 6ET 3EHT / 6EHT Power line L L Device Power line L Device Power line L 1 2 1 Device 1 x 15ET & 15VT 10EHT 15EHT 20ET & 20VT Power line L Device Power line L L L Power line Device 2 Device 1 2 1 L L 1 2 x = only 20A version x Typ. Insertion Loss asym. sym. dB dB dB 90 90 90 80 80 80 70 70 70 60 60 60 50 50 50 40 40 40 30 30 30 20 20 20 10 10 10 0 0 0 0,01 0,1 110 30 0,01 0,1 110 30 0,01 0,1 110 30 Frequency in MHz Frequency in MHz 10ET Frequency in MHz 3ET 6ET dB dB dB 90 90 90 80 80 80 70 70 70 60 60 60 50 50 50 40 40 40 30 30 30 20 20 20 10 10 10 0 0 0 0,01 0,11 10 30 0,01 0,1 110 30 0,01 0,1 110 30 Frequency in MHz Frequency in MHz 15ET Frequency in MHz 10VT 15VT All specifications subject to change. Consult Tyco Electronics for latest design specifications. 58 Case Styles and typ. Sizes Terminal variant 1 Terminal variant 3 85,9 max 3A / 6A 3A / 6A 12,7 27 9,8 74,6±0,4 4,8±0,25 Dia 8,9 Blue 45,9 46 Gr./Yellow Brown 19 28,9 52.0 max 11,2 Brown Blue 14,5 20,3 74,6±0,4 100 46 max 64,8 min Faston 6,35 52.0 33 Hole 1,8 Dia Mounting holes 4,8 Dia 85,8 6,4±1,5 90,4 Terminal variant 3 10A Terminal variant 1 Blue Blue 10A Green/Yellow 33,0(2) 57,4 11,4 Brown Brown (2) 6,4±1,5 45,7 93,7 16,5 45,7 103,2±0,4 Wire length 100 min. 113,5 Mounting holes 4,8 Dia 57,7 11,9 113,5 103,2±0,4 Terminal variant 6 50,8 15A / 20A ±0,3 4,8 –0,3 Dia Device Power line 88,9 79,2 100,6 ±0,4 10,8 min 92,1 REF 12,7 max 119,1 151,1 55,4 Terminals No. 8-32 Mounting holes 5,2 x 4,0 Terminal variant 1 Terminal variant 7 15A / 20A 3A / 6A 6R 4 Dia 138,4 79,2 23,1 55,4 Panel cutout for back mounting 32,9 40,0 Tolerance±0,1 Tapped insert 1 16,0 6 x 32 / 4 Faston 6,35 Hole 1,8 Dia 50,8±0,3 Faston 6,35 88,9 100,6 Hole 1,8 Dia 40,0 ±0,4 57,2 Mounting holes 5,2 x 4,0 78,0 45,0 89,4 Typ. Insertion Loss asym. sym. dB dB 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 10 0 0 0,01 0,1 1 10 30 0,01 0,1 110 30 Frequency in MHz Frequency in MHz 20ET 20VT All specifications subject to change. Consult Tyco Electronics for latest design specifications. 59 V D E Chassis/Back Panel Mount Filters with/ according IEC 950 without IEC Connector EP/VP-Series - Two stage filter series for equipment with interferences difficult to suppress Type Max.current Inductance Capacity Tapped Dimensions (mm) UL/VDE L L C C insert A B C D E 1 2 X Y 3EP1 3A 2x7mH 2x7mH 3x0,27µF 2x2,8nF 97,7 52,345,1 74,6 85,1 3EP3 3A 2x7mH 2x7mH 3x0,27µF 2x2,8nF 65,0 52,345,1 74,6 85,1 3EP7 3A 2x7mH 2x7mH 3x0,27µF 2x2,8nF81,5 57,145,140,0 16,8 3EP7M 3A 2x7mH 2x7mH 3x0,27µF 2x2,8nF81,5 57,145,140,0 16,8 6EP1 6A/5A2x7mH 2x7mH 3x0,27µF 2x2,8nF6-32x1/4168,1 52,4 57,9 142,9 153,2 6EP3 6A/5A2x7mH 2x7mH 3x0,27µF 2x2,8nFM3x0,5 135,3 52,4 57,9 142,9 153,2 10EP1 10A/8A2x7mH 2x7mH 3x0,27µF 2x2,8nF 168,1 52,4 70,6 142,9 153,2 10EP3 10A/8A2x7mH 2x7mH 3x0,27µF 2x2,8nF 135,3 52,4 70,6 142,9 153,2 20EP1/6 20A/20A2x1,73mH 2x1,73mH 2x1,0µF 2x2,8nF 127,3 57,7 45,7 103,2 113,5 20VP1/6 20A/20A2x1,73mH 2x1,73mH 2x1,0µF 2x10nF 127,3 57,7 45,7 103,2 113,5 Max. leakage current line to ground 0.4 mA at 250 VAC/50 Hz Case Styles and typ. Sizes EP1 EP6/VP6 EP7 / EP7M (Tapped insert with metrical thread) E Tapped insert D B D B D C E Faston 6,35 Hole 1,8 Dia A A E Mounting holes 4,8 Dia EP3 A C Terminal threads No 8-32 Brown Brown C 6R 4 Dia B Blue Blue 23,1 B Faston 6,35 (3) Hole 1,8 Dia 32,9 A Green/ C Panel cutout for back mounting 40,0 Yellow D Wire length 100 min. Tolerance±0,13 Mounting holes 4,8 Dia E Typ. Insertion Loss asym. sym. Electrical Schematic dB dB 90 90 80 80 70 70 60 60 Power line L 50 L 2 Device 50 1 40 40 30 30 20 20 10 10 0 0 0,01 0,11 10 30 0,01 0,11 10 30 Frequency in MHz 6EP Frequency in MHz 3EP dB dB dB 90 90 90 80 80 80 70 70 70 60 60 60 50 50 50 40 40 40 30 30 30 20 20 20 10 10 10 0 0 0 0,01 0,11 10 30 0,01 0,11 10 30 0,01 0,11 10 30 Frequency in MHz 20VP Frequency in MHz 10EP Frequency in MHz 20EP All specifications subject to change. Consult Tyco Electronics for latest design specifications. 60 V D E Chassis-mount Filters according IEC 950 X-,Z-Series - Optimized differential and common mode performance filter to clean up switch mode power supplies and similar equipment Type Max.current Inductance Capacity Dimensions (mm) UL/VDEC C A B C D E X Y 3EX1 3A/2A 2x2,3mH 0,27+0,1µF 2x4nF 76,7 46,7 29,5 60,3 70,8 3EZ1* 3A/2A 2x13,77mH 0,47+0,27µF 2x4nF 89,9 52,8 33,3 74,6 85,1 Max. leakage current line to ground 0.5 mA at 250 VAC/50 Hz *Suitable for frequency applications For medical Applications Type Max.current Inductance Capacity Dimensions (mm) UL/VDEC C A B C D E X Y 3EHZ1 3A/2A 2x13,77mH 0,47+0,27µF – 89,9 52,8 33,3 74,6 85,1 Max. leakage current line to ground 250 VAC/50 Hz 5 µA X-Series -Normal attenuation Z-Series -Very high attenuation Example: RFI suppression in electronic devices acc. to Example: RFI suppression in electronic devices also equipped FCC Part 15J, Class B. with switching power supplies according to VDE 0871, Class B. Electrical Schematic 3EX1/3EZ1 3EHZ1 Power line Device Power line Device Case Styles and typ. Sizes D For PCB mounting also with plastic case available (see XP, YP, ZP Series) B C E Faston 6,35 Mounting holes 4,8 Dia A Typ. Insertion Loss asym. sym. Minimum Insertion Loss dB dB dB 90 90 90 80 80 80 70 70 70 60 60 60 50 50 50 40 40 40 30 30 30 20 20 20 10 10 10 0 0 0 0,01 0,11 10 30 0,01 0,11 10 30 0,01 0,11 10 30 Frequency in MHz Frequency in MHz Frequency in MHz 3EZ1 3EX1 3EHZ1 All specifications subject to change. Consult Tyco Electronics for latest design specifications. 61 V D E Chassis/Back Panel according IEC 950 For F3426 VDE only Mount Filters with/ without IEC Connectors Q-Series - Very high attenuation and low leakage currents also at high current transients (switching power supplies) - Optimizied filter with regard to attenuation and size (exceeding T-Series) - Especially suited for RFI suppression in equipment above 10 kHz - EHQ-types for medical applications Type Max.leak- Capac. Type Max.leak- Capac. Max.current Inductance Capacity Tapped Dimensions (mm) age current C age current C UL/VDE L L C insert A B C D E Y Y 1 2 X 3EQ1* Line 2x3nF 3VQ1 Line 2x10nF 3A/2A 2x31,8mH 2x0,4mH 2x0,47µF 97,8 52,445,1 74,6 84,6 3EQ3* to 2x3nF 3VQ3 to 2x10nF 3A/2A 2x31,8mH 2x0,4mH 2x0,47µF 65,0 52,445,1 74,6 84,6 3EQ7 ground 2x3nF 3VQ7 Ground 2x10nF 3A/2A 2x31,8mH 2x0,4mH 2x0,47µF6-32x1/4 92,5 57,245,140,0 77,0 250VAC 3VQ7M 250VAC 2x10nF 3A/2A 2x31,8mH 2x0,4mH 2x0,47µFM 4x0,5 92,5 57,245,140,0 77,0 3EQ8 50Hz 2x3nF 3VQ8 50Hz 2x10nF 3A/2A 2x31,8mH 2x0,4mH 2x0,47µF6-32x1/4 77,8 57,245,140,0 16,0 3EQ8M 0,42mA2x3nF 3VQ8M 1,25mA2x10nF 3A/2A 2x31,8mH 2x0,4mH 2x0,47µFM 3x0,5 77,8 57,245,140,0 16,0 6EQ1* 2x4nF6A/5A2x47,2mH 2x1,6mH 1,5+0,47µF 126,5 57,445,7 103,2 113,5 6EQ3* 2x4nF6A/5A2x47,2mH 2x1,6mH 1,5+0,47µF93,6 57,445,7 103,2 113,5 6EQ8 0,5mA2x4nF6A/5A2x47,2mH 2x1,6mH 1,5+0,47µF6-32x1/4135,2 50,7 44,140,0 68,6 6EQ8M 2x4nF6A/5A2x47,2mH 2x1,6mH 1,5+0,47µFM 3x0,5 135,2 50,7 44,140,0 68,6 20EQ1 2x4nF 20VQ1 2x10nF 20A/20A2x3,26mH 2x3,26mH 2x2,2µF 168,1 52,6 57,9 142,9 153,2 *Suitable for frequency converter applications For Medical Applications Type Max.leak- Max.current Inductance Capacity Tapped Dimensions (mm) age current UL/VDE L L C insert A B C D E 1 2 X 3EHQ1 Line 3A/2A 2x31,8mH 2x0,4mH 0,27+0,27+0,47µF 97,8 52,445,1 74,6 84,6 3EHQ3 to 3A/2A 2x31,8mH 2x0,4mH 0,27+0,27+0,47µF 65,0 52,445,1 74,6 84,6 3EHQ8 ground 3A/2A 2x31,8mH 2x0,4mH 0,27+0,27+0,47µF6-32x1/4 77,8 57,245,140,0 16,0 3EHQ8M 250VAC 3A/2A 2x31,8mH 2x0,4mH 0,27+0,27+0,47µFM 3x0,5 77,8 57,245,140,0 16,0 6EHQ1 50Hz 6A/5A2x47,2mH 2x1,6mH 1,5+0,47µF 126,5 57,445,7 103,2 113,5 6EHQ3 6A/5A2x47,2mH 2x1,6mH 1,5+0,47µF93,6 57,445,7 103,2 113,5 6EHQ8 5µA 6A/5A2x47,2mH 2x1,6mH 1,5+0,47µF6-32x1/4135,2 50,7 44,140,0 68,6 6EHQ8M 6A/5A2x47,2mH 2x1,6mH 1,5+0,47µFM 3x0,5 135,2 50,7 44,140,0 68,6 Special Construction Style Type Max. current Max. leakage current Inductance Capacity VDE line to ground 250 VAC L L C C 1 2 X Y F-3426B 1A 2,5mA2x21,1mH 2x0,37mH 0,2µF 2x14nF Electrical Schematic 3EQ & 3VQ 6EQ Power line Device Power line L Device L 1 L 2 1 L 2 3EHQ 6EHQ Power line Device L 1 Device Power line L L 2 1 L 2 F-3426 Power line Device L 1 L 2 All specifications subject to change. Consult Tyco Electronics for latest design specifications. 62 Case Styles and typ. Sizes Q3 Q1 Blue Blue B Green/Yellow B Brown Brown D C A E 3A model C D A E Wire length 100 min Mounting holes 4,8 Dia Faston 6.35 B Hole 1,8 Dia 3A Q8 & Q8M Mounting holes 4,8 Dia Tapped insert C Brown 6A model Green/Yellow F-3426B B D Blue 12,5 33,0 Faston 6,35 Hole 1,8 Dia E A C 20,0 70,0 6,0R 4,0 Dia 23,1 19,5 46,0 56 32,5 ±0,1 22,6 ±0,3 21,5 32,9 Wire length 150 min 40,0 11,5 Panel cutout for back mounting 32,4 2,0 4,4 Dia Tolerance±0,1 3A Q7 6A Q8 & Q8M Tapped insert M=metric M3x0,5 Tapped insert inch-thread 6-32x1/4 Green/ Yellow DB C Blue Brown E E D B A C A Wire terminals also valid for 6EQ3 Typ. Insertion Loss asym. sym. dB dB dB 90 90 90 80 80 80 70 70 70 60 60 60 50 50 50 40 40 40 30 30 30 20 20 20 10 10 10 0 0 0 0,01 0,11 10 30 0,01 0,11 10 30 0,01 0,11 10 30 Frequency in MHz Frequency in MHz 20EQ Frequency in MHz 3EQ 6EQ dB dB dB 90 90 90 80 80 80 70 70 70 60 60 60 50 50 50 40 40 40 30 30 30 20 20 20 10 10 10 0 0 0 0,01 0,11 10 30 0,01 0,11 10 30 0,01 0,11 10 30 Frequency in MHz 3VQ Frequency in MHz 20VQ Frequency in MHz F-3426B All specifications subject to change. Consult Tyco Electronics for latest design specifications. 63 LOAD V D E Chassis-mount Filters FC-Series up to 36A -High performance single phase filter -Suitable to meet latest EMC standards (EN55011, -14, UL1283 and EN133200) -Applicable in single phase-powered FC-drives with long motor-cables -Very high insertion loss -Double stage design -Shock protected screw type terminals -Ideal for EMC-trouble shooting and EMC-refurbishing in the field Type Operating Max. Leakage Inductance Capacity Type of voltage current current L C C connection X Y AC 50/60Hz 250V/50Hz 2 6FC10 250V 6A 5,2mA 8,8mH 4,4µF62nF Terminal block 4mm 2 12FC10 250V 12A 5,2mA 5,6mH 4,4µF62nF Terminal block 4mm 2 16FC10 250V 16A 5,2mA 5,5mH 4,4µF62nF Terminal block 4mm 2 25FC10 250V 25A 5,2mA 5,0mH 4,4µF62nF Terminal block 6mm 2 36FC10 250V 36A 5,2mA2,0mH 4,4µF62nF Terminal block 6mm 2 50FC10 250V 50A 6,5mA2,0mH 6,6µF77nF Terminal block 6mm 2 12FC10B 250V 12A 7mA 5,4mH 4,4µF62nF Terminal block 4mm 2 16FC10B 250V 16A 7mA4,9mH 4,4µF62nF Terminal block 4mm 2 25FC10B 250V 25A 7mA 5,0mH 4,4µF62nF Terminal block 6mm 2 36FC10B 250V 36A 7mA2,0mH 4,4µF62nF Terminal block 6mm 2 50FC10B 250V 50A 7mA2,0mH 6,6µF62nF Terminal block 6mm Earth-conductor-connection on both sides with threaded studs Caution: Increased leakage current - please observe mounting instructions Case Styles and typ. Sizes 6FC10 12FC10 / 16FC10 116 max 8-32 45,2 max 131,6 max Screws 10,9 (2x) 94,0 max 6,6 (4) (4x) 5,16 x 3,96 20,6 35,1 55,5 Hole (4) (4) 21 max 32 30,5 78,7 57,4 35,1 68,0 135 max max ±,51 (2) 139 max 85,4 17,5 50,8±,25 Phoenix VDFK4 8-32 Screw (4x) 114,0 (2x) L L 101 79,5 I O 40 max 30 LABEL max N A 88,9 E D ±0,4 Terminals 2 6, 12, 16A : to 4mm 2 25, 36, 50A : to 6mm 50,8±0,3 5,2 x 4,0 Hole (4x) All specifications subject to change. Consult Tyco Electronics for latest design specifications. 64 LINE Typ. Insertion Loss asym. sym. dB dB dB 90 90 90 80 80 80 70 70 70 60 60 60 50 50 50 40 40 40 30 30 30 20 20 20 10 10 10 0 0 0 0,01 0,11 10 30 0,01 0,11 10 30 0,01 0,11 10 30 Frequency in MHz Frequency in MHz 6FC10 12FC10 Frequency in MHz 16FC10 dB dB dB 90 90 90 80 80 80 70 70 70 60 60 60 50 50 50 40 40 40 30 30 30 20 20 20 10 10 10 0 0 0 0,01 0,11 10 30 0,01 0,11 10 30 0,01 0,11 10 30 Frequency in MHz Frequency in MHz Frequency in MHz 12FC10B/16FC10B 25FC10 36FC10/50FC10 dB dB dB 90 90 90 80 80 80 70 70 70 60 60 60 50 50 50 40 40 40 30 30 30 20 20 20 10 10 10 0 0 0 0,01 0,11 10 30 0,01 0,11 10 30 0,01 0,11 10 30 Frequency in MHz Frequency in MHz Frequency in MHz 25FC10B 36FC10B 50FC10B Case Styles and typ. Sizes Electrical Schematic 25FC10 / 36FC10 / 50FC10 FC10 177 max 8-32 Screw (2x) 9 Device Power line 65 max 40,1 * 21 10 9 170 6,6 50A only * (4x) 9 25, 36 and 50A only Phoenix VDFK6 (4x) FC10B L L I O 30 LABEL 140 N A 125 max E D ±0,5 111 Device max Power line 70,0±0,3 151 max All specifications subject to change. Consult Tyco Electronics for latest design specifications. 65 2-Phase Filters IK-Series according IEC 950 - Designed for 2-phase industrial applications Type Operating Max. Max. leakage Inductance Capacity Connections voltage current current C C Power line Device X Y AC 50/60Hz 250V/50Hz 1IK1C 500V 1x1A 1,2mA 1,1mH 0,22µF 11nF Faston Faston 6IK1 480V 2x6A 1,2mA 1,9mH 0,54µF 11nF Faston Faston 16IK10 480V 2x16A 3,2mA 6,1mH 2,2µF 30nF Terminal screw Cable 35IK10 480V 2x35A 3,2mA 3,0mH 2,2µF 30nF Terminal screw Cable 50IK10 480V 2x50A 3,2mA 1,7mH 2,2µF 30nF Terminal screw Terminal screw 80IK10 480V 2x80A 7,9mA 1,0mH 2,2µF 94nF Terminal screw Terminal screw Electrical Schematic Power Device Typ. Insertion Loss asym. sym. dB dB -100 90 80 -80 70 60 -60 50 40 -40 30 20 -20 10 0 0,1 1 10 30 0,01 0,1 1 10 30 1IK1C Frequency in MHz Frequency in MHz 6IK1 dB dB -100 -100 -80 -80 -60 -60 -40 -40 -20 -20 0,01 0,1 1 10 30 0,01 0,1 1 10 30 Frequency in MHz 16IK10/35IK10 Frequency in MHz 50IK10/80IK10 66 All specifications subject to change. Consult Tyco Electronics for latest design specifications. Case Styles and typ. Sizes 1IK1C 6IK1 33,0(2) 85,1 15,0 11,4 max (2) 74,4 11,9 ±0,38 45,7 16,5 52,6 57,7 11,9 25,4 113,5 max 103,2 ±0,4 4,75 Dia ±0,25 4,8 –0,3 Dia 65,0 38,9 Device Power line max max 16,4 max 10,8 min 92,1 REF 12,7 max Faston 6,35 (6) 119,1 1,75 Dia ± 0,08 16IK10/35IK10 97,8 max Phoenix VDFK6 (3) 121 max Type Dimensions AB C 16IK10 50,5 21 11 B 35IK10 55,5 31 16 A 40 C 161 max Black 136 180 mm min 10 38 ±0,1 30 20 50 ±0,5 Brown 180 mm min 150 ±0,2 Gr/Yellow 5,5 Dia (4) 200 mm min 50IK10/80IK10 Screw 1/4x20 (2) Phoenix HDFK25VP (4) 90,0 max 75 24 190 max Mounting holes 6,5 Dia (4) 60 ±0,2 40 100 max 10 160 175 ±0,2 240 max All specifications subject to change. Consult Tyco Electronics for latest design specifications. 67 V D E 3-Phase Filters up to 30A 20AYT6C and 60AYT6C also TÜV A-Series 3-phase RFI filters with high according IEC 950 attenuation in wye/delta applications with integrated ground-inductor - Max. operating voltage 440V Main Keypoints - Effective by symmetrical and asymmetrical load - Universal possibility in the industial field - Input filters for motor drives Type Max. current Max. Inductance Capacity Ground Dimensions (mm) UL voltage L L C C wire A B C D E 1 2 X Y 20AYP6C 20A 440V 4x4,44mH – 3x3,2µF+ 4x18nF 0,261mH 224,0 141,5 65,0 117,2 38,1 6x47nF 20AYT6C 20A 440V 4x3,5mH 4x3,5mH 6x1,5µF+ 4x26nF 0,261mH 351,0 141,5 65,0 117,2 38,1 3x1,47µF 30AYP6C 30A 440V 4x1,97mH – 3x3,2µF 4x18nF 0,261mH 224,0 141,5 65,0 117,2 38,1 6x47nF 30AYT6C 30A 440V 4x1,66mH 4x1,66mH 6x1,5µF 4x26nF 0,261mH 351,0 141,5 65,0 117,2 38,1 3x1,47µF 45AYP6C 45A 440V 4x1,1mH – 6x1,0µF 8x10nF 0,261mH 239,5 175,8 122,4 151,1 95,3 45AYT6C 45A 440V 4x1,1mH 4x1,1mH 9x1,5µF 4x26nF 0,261mH 351,3 175,8 122,4 151,1 95,3 60AYP6C 60A 440V 4x0,74mH – 6x1,0µF 8x10nF 0,242mH 239,5 175,8 122,4 151,1 95,3 60AYT6C 60A 440V 4x0,74mH 4x0,74mH 9x1,5µF 4x26nF 0.242mH 351,3 175,8 122,4 151,1 95,3 Max. leakage current lead/ground 3.4 mA at 250 VAC/50 Hz 1 8 mounting studs No. 8-32 for installation. 10 mounting studs / x20 with nuts and washers for cable connection. 4 Electrical Schematic AYP6C AYT6C Power line L L Power line L Device Device 1 2 1 N N« N N« PE PE« PE PE« Typ. Insertion Loss asym. sym. dB dB dB 90 90 90 80 80 80 70 70 70 60 60 60 50 50 50 40 40 40 30 30 30 20 20 20 10 10 10 0 0 0 0,01 0,1 1 10 30 0,01 0,1 1 1030 0,01 0,1 1 10 30 Frequency in MHz Frequency in MHz Frequency in MHz 20AYT6C 30AYP6C 20AYP6C dB dB dB 90 90 90 80 80 80 70 70 70 60 60 60 50 50 50 40 40 40 30 30 30 20 20 20 10 10 10 0 0 0 0,01 0,1 1 10 30 0,01 0,1 1 10 30 0,01 0,1 1 10 30 Frequency in MHz Frequency in MHz 45AYP6C Frequency in MHz 45AYT6C 30AYT6C 68 All specifications subject to change. Consult Tyco Electronics for latest design specifications. Case Styles and typ. Sizes C A E 13 58 12,3 D B 25 22,4 46 Mounting Accessories Shock protection incl. nuts and lock washers Shock protection incl. nuts and lock washers AA406 for 20/30A version AA406A for 20/30A version AA407 for 45/60A version 40,0 61,5 95±0,2 25,0 142 max Shock protection incl. nuts and lock washers AA407A for 45/60A version AA400 Two brackets only AA405 Two brackets only Typ. Insertion Loss asym. sym. dB dB 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 10 0 0 0,01 0,1 1 10 30 0,01 0,1 1 10 30 Frequency in MHz Frequency in MHz 60AYP6C 60AYT6C All specifications subject to change. Consult Tyco Electronics for latest design specifications. 69 (pending) 3-Phase plus Neutral Filters AYC-Series - Suitable to meet latest EMC standards (EN55011, -14, UL1283 and EN133200) - Designed for very noisy delta and wye applications, e.g. frequency converters with long motor cables - Very high insertion loss - Low leakage currents - Ideal for EMC - trouble shooting and EMC - refurbishing in the field - Nominal operating voltage 480V Type Operating Max. Max. leakage current Inductance Capacity Terminal voltage current voltage drop N to PE C C in-/output X Y AC 50/60Hz 2 16AYC10B 480V 4x16A 0,70mA/V 2,66mH 4,5µF2µF Terminal block 4mm 2 25AYC10B 480V 4x25A 0,70mA/V 3,96mH 6,6µF2µF Terminal block 6mm 2 36AYC10B 480V 4x36A 0,70mA/V 1,66mH 6,6µF2µF Terminal block 10mm 2 63AYC10B 480V 4x63A 0,70mA/V 1,00mH 8,8µF2µF Terminal block 16mm 2 80AYC10B 480V 4x80A 0,70mA/V 0,69mH 8,8µF2µF Terminal block 50mm 2 110AYC10B 480V 4x110A 0,70mA/V 0,53mH 8,8µF2µF Terminal block 50mm 2 150AYC10B 480V 4x150A 0,70mA/V 0,53mH 11,0µF2µF Terminal block 50mm 2 150AYC10B-95 480V 4x150A 0,70mA/V 0,53mH 11,0µF2µF Terminal block 95mm 2 180AYC10B 480V 4x180A 1,05mA/V 0,35mH 13,2µF3µF Terminal block 95mm 2 200AYC10B 480V 4x200A 1,05mA/V 0,35mH 13,2µF3µF Terminal block 95mm Electrical Schematic Case Styles and typ. Sizes 25AYC10B Device Power line Ground terminal M5 screw 240 max (2 places) 214 3Nm max. torque 40 ref 64 max 31 ref Phoenix VDFK6 (6 places) 246 ref N´ 1,5Nm max. torque N 5 ref 6,6 ref (4 places) PE PE´ 129 L L max I O 15 ref 145 16AYC10B N A ± 0,5 E D 15 ref 159 max M5 screw Phoenix VDFK4 (2 places) 49 (8 places) 177 max 3Nm max. torque 25,6 ref 0,6Nm max torque 21 ref 115 ± 0,3 148 65 10 ref 40,1 1,0 mat. thickness 36AYC10B Ground terminal 263 ref 170 ref M5 screw 240 max (2 places) 6,6 ref 214 3Nm max. torque 39,6 64 15 ref 6 max Phoenix HDFK10 L L L L (8 places) 125 II O O 1,5Nm max. torque 6,6 ref N N 140 111 A A (4 places) E E D D 5,0 ref 15 ref 10,0 ref 129 L L max I O 145 N A ± 0,5 70,0 ± 0,3 E 159 D 15,6 ref max 102 ref 44 ref 151 max 115 ± 0,3 25,6 148 1,0 mat. thickness 70 All specifications subject to change. Consult Tyco Electronics for latest design specifications. Typ. Insertion Loss asym. sym. dB dB dB 90 90 90 80 80 80 70 70 70 60 60 60 50 50 50 40 40 40 30 30 30 20 20 20 10 10 10 0 0 0 0,01 0,1 1 10 30 0,01 0,1 1 10 30 0,01 0,1 1 10 30 Frequency in MHz Frequency in MHz Frequency in MHz 16AYC10B 25AYC10B 36AYC10B dB dB dB 90 90 90 80 80 80 70 70 70 60 60 60 50 50 50 40 40 40 30 30 30 20 20 20 10 10 10 0 0 0 0,01 0,1 1 10 30 0,01 0,1 1 10 30 0,01 0,1 1 10 30 Frequency in MHz Frequency in MHz Frequency in MHz 63AYC10B 80AYC10B 110AYC10B dB dB 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 10 0 0 0,01 0,1 1 10 30 0,01 0,1 1 10 30 Frequency in MHz Frequency in MHz 150AYC10B 180AYC10B 150AYC10B-95 200AYC10B Case Styles and typ. Sizes 63AYC10B 80AYC10B Ground terminal 279 ref 110AYC10B M6 screw 240 max (2 places) 150AYC10B 214 6Nm max. torque 39,6 141 max 75 6 max 50,5 Phoenix HDFK16 14,7 (8 places) 2,5Nm max. torque 6,6 ref 307 (4 places) 115±0,5 129 L L max 12 I O 168 75,2 145 48 ref N A ± 0,5 E D 159 155±0,5 max M10 6,6±0,2 Phoenix HDFK50 (8) 34 221 max 6Nm max. torque 115 ± 0,3 15,0 148 1,0 mat. thickness 180AYC10B 150AYC10B-95 200AYC10B 141 141 max max 62,0 62,0 14,7 23,7 399 max 320 max 100 141 141 100 168 168 82,5 82,5 155±0,5 155±0,5 ±0,2 ±0,2 115±0,5 M10 M10 6,6±0,2 Phoenix HDFK95 (8) 6,6±0,2 Phoenix HDFK95 (8) 34 12Nm max. torque 300 max 34 12Nm max. torque 221 max All specifications subject to change. Consult Tyco Electronics for latest design specifications. 71 A B C Device Line A B C 3-Phase Filters ADT-Series - Very high insertion loss for delta applications and difficult cases of RFI suppression - Max. operating voltage 480 VAC/Ph/Ph - EMC conform design - Shielding ≥100 dB - Voltage drop ≤1% - Peak current carrying capacity 15 Min/140% I nom - Case sheet metal, hermetically sealed, corrosion protected, varnished surface Type Max. Max. leakage Dimensions Terminal Type Max. max. leakage Dimensions Terminal Max. current current A B C D thread current current A B C D thread torque 230 VAC/50 Hz 230 VAC/50 Hz 63ADT6 63A 0,76 A 254,0 254,0 89,0 127,0 3/8-16 63ADT6-S 63A 1,5 A 381,0 254,0 114,3 127,0 3/8-16 2Nm 100ADT6 100A 0,76 A 381,0 254,0 114,3 127,0 3/8-16 100ADT6-S 100A 2,7 A 381,0 279,4 114,3 127,0 3/8-16 2Nm 160ADT6 160A 0,76 A 381,0 254,0 114,3 127,0 7/16-20 160ADT6-S 160A 2,7 A 457,2 330,2 114,3 177,8 7/16-20 5Nm 200ADT6 200A 0,76 A 381,0 254,0 114,3 127,0 7/16-20 200ADT6-S 200A 2,7 A 457,2 330,2 114,3 177,8 7/16-20 5Nm 300ADT6 300A 0,76 A 381,0 254,0 114,3 127,0 1/2-20 Caution: Increased leakage current - please observe mounting instructions Other designs - also with overvoltage protection - on request Suitable for frequency converter applications Case Styles and typ. Sizes 50,8 A 19 19 25,4 19 19 19 31,8 63,5 D B 30,0 x 14,2 Cutout 25,4 C 17,5 50,8 3/8-16 steel 10Nm max. forque Terminal see table Electrical Schematic ADT6S ADT6 Device Power line Device Power line PE PE´ PE PE´ 72 All specifications subject to change. Consult Tyco Electronics for latest design specifications. Typ. Insertion Loss asym. sym. dB dB 100 100 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 10 0 0 0,01 0,1 1 10 100 300 0,01 0,1 1 10 100 300 63ADT6-S Frequency in MHz 63ADT6 Frequency in MHz dB dB 100 100 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 10 0 0 0,01 0,1 1 10 100 300 0,01 0,1 1 10 100 300 Frequency in MHz 100ADT6-S 100ADT6 Frequency in MHz dB dB 100 100 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 10 0 0 0,01 0,1 1 10 100 300 0,01 0,1 1 10 100 300 160ADT6-S Frequency in MHz 160ADT6 Frequency in MHz dB dB 100 100 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 10 0 0 0,01 0,1 1 10 100 300 0,01 0,1 1 10 100 300 200ADT6-S 200/300ADT6 Frequency in MHz Frequency in MHz Accessories Protective cover (2ea.) with nuts and lockwashers for case width (Ref. B) 254,0 mm AA-500A 279,4 mm AA-501A 330,2 mm AA-502A Mounting bracket for wall/floor mounting with nuts and lockwashers for case width A B 254,0 mm AA-506 190,5 mm 279,4 mm AA-507 216,0 mm 330,2 mm AA-508 267,0 mm All specifications subject to change. Consult Tyco Electronics for latest design specifications. 73 440V AC for 3-Phase Filters 16AYA6/A, AYA-Series 25AYA6/A - 4-wire-style suitable for high 36AYA6/A 50AYA6/A industrial requirements - Applicable in wye and delta pending for others configurations Type Operating Max. Max. leakage current Inductance Capacity Terminal voltage current voltage drop N to PE C C in-/output X Y AC 50/60Hz 16AYA6/A 480V 4x16A 20µA/V 1,2mH 2,1µF 30nF Threaded bolt 8-32; turn. mom. 3Nm max 25AYA6/A 480V 4x25A 20µA/V 1,1mH 4,4µF 30nF Threaded bolt 8-32; turn. mom. 3Nm max 36AYA6/A 480V 4x36A 20µA/V 1,0mH 4,4µF 30nF Threaded bolt 10-32; turn. mom. 4Nm max 50AYA6/A 480V 4x50A 20µA/V 0,67mH 4,4µF 30nF Threaded bolt 1/4-20; turn. mom. 5Nm max 63AYA6/A 480V 4x63A 20µA/V 0,34mH 4,4µF 30nF Threaded bolt 1/4-20; turn. mom. 5Nm max 100AYA6/A 480V 4x100A 20µA/V 0,25mH 4,4µF 30nF Threaded bolt 1/4-20; turn. mom. 5Nm max 2 16AYA10 480V 4x16A 20µA/V 1,2mH 2,1µF 30nF Terminal block 4mm 2 36AYA10 480V 4x36A 20µA/V 1,0mH 4,4µF 30nF Terminal block 10mm 2 63AYA10 480V 4x63A 20µA/V 0,34mH 4,4µF 30nF Terminal block 16mm Electrical Schematic Device Power line N N´ PE PE´ Typ. Insertion Loss asym. sym. dB dB dB 90 90 90 80 80 80 70 70 70 60 60 60 50 50 50 40 40 40 30 30 30 20 20 20 10 10 10 0 0 0 0,01 0,1 1 10 30 0,01 0,1 1 10 30 0,01 0,1 1 10 30 Frequency in MHz 16AYA6/A 25AYA6/A Frequency in MHz 50AYA6/A Frequency in MHz dB dB 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 10 0 0 0,01 0,1 1 10 30 0,01 0,1 1 10 30 36AYA6/A/10 Frequency in MHz Frequency in MHz 63AYA6/A/10 74 All specifications subject to change. Consult Tyco Electronics for latest design specifications. Case Styles and typ. Sizes 151,0 max 16AYA6 16AYA6-A 16AYA6 25AYA6 25AYA6 25 44,0 ±0,3 25AYA6-A 50 max 36AYA6 36AYA6-A 36AYA6 63AYA6 50AYA6 50AYA6-A 65 max 70,0 ±0,3 63AYA6 63AYA6-A 14 M5x8 (4) 15 75,0 ±0,3 110,0 max 111 max 140 125 24,6 max ±0,5 73,8 39 C = Threaded bolt 6,6 (4) 50max 16/25AYA6 102 65max 36-63AYA6 151 max 201 36AYA10 16AYA10 M5 screw Phoenix VDFK4 (8 pieces) M5 screw (2 pieces) 0,6Nm max. Phoenix HDFK10 (8x) (2 places) 3Nm max. 177 max. torque 1,5Nm max torque 3Nm max. torque 177 max torque 21 ref 10 ref 50 65 5,3 ref max. 40,1 40,1 170 ref 24,5 ref 6,6 ref 10 ref 6,6 ref 15 ref L L L L 15 ref 125 II L L O O L L 125 140 N N 111 A A II O O E E D D 140 N N 111 A A E E D D 15 ref 15 ref 39,5 ref 70,0 ± 0,3 15,6 ref 70,0 ± 0,3 15,6 ref 102 ref 102 ref 151 max 151 max. 63AYA10 Ground terminal 279 ref M6 screw 240 max (2 places) 214 5Nm max. torque 24,0 64 6 max Phoenix HDFK16 (8 places) 6,6 ref (4 places) 28 129 L L max 12 I O 145 48 ref N A ± 0,5 159 E D max 115 ± 0,3 20,0 148 1,0 mat. thickness All specifications subject to change. Consult Tyco Electronics for latest design specifications. 75 V D E 3-Phase Filters not for 50AYO6 and 100AY06 AYO-Series - 3-Phase RFI filter for wye and according IEC 950 delta applications - Best price/performance ratio Type Operating Max. Max. leakage current Inductance Capacity voltage current 250 VAC / 50 Hz C C X Y AC 50/60Hz 3AYO1 440V 3A 1,5 mA 4x1,0mH 0,1µF 15nF 6AYO1 440V 6A 1,5 mA 4x0,45mH 0,1µF 15nF 10AYO1 440V 10A 1,5 mA 4x0,2mH 0,1µF 15nF 20AYO1 440V 20A 3,5 mA 4x0,12mH 0,1µF 47nF Case Styles and typ. Sizes 85,1 3AY01/6AY01 74,6 10AY01/20AY01 26,9 52,4 65,0 11,4 38,7 85,6 Typ. Insertion Loss asym. sym. Electrical Schematic dB dB 80 80 70 70 60 60 AYO 50 50 40 40 30 30 Power line Device 20 20 10 10 0 0 0,1 1 10 30 0,1 1 10 30 Frequency in MHz Frequency in MHz 6AYO1 3AYO1 dB dB 80 80 70 70 N N´ 60 60 50 50 PE 40 40 30 30 20 20 10 10 0 0 0,1 1 10 30 0,1 1 10 30 Frequency in MHz 20AYO1 10AYO1 Frequency in MHz 76 All specifications subject to change. Consult Tyco Electronics for latest design specifications. Flat connector 6,35 4,8 Dia F-2810, F-3297, F-3737 3-Phase Filters F-Series F-3297 3-phase RFI filter with high attenuation in wye/delta-applications according IEC 950 - Max. operating voltage 440V/480V/660V - Low leakage current Type Operating Max. Leakage Circuit Inductance Capacity Case Type voltage current current No. L L C C No. of 1 2 X Y AC 50/60Hz connection F3719* 440V 8A 3,0mA 5 3x2,8mH 3x380µH 3x2,2µF + 3x2,3µF 3x15nF 2 Terminal screw/cable F3727* 440V 10A 3,4mA 2 4x4,44mH 4x74µH 3x3,7µF + 3x3,2µF 25nF 3 Mounting stud F3727A 440V 10A 3,4mA 2 4x4,44mH 4x74µH 3x3,7µF + 3x3,2µF 25nF 7 Terminal screw F2810 440V 10A 3,5mA 6 4x0,94mH 4x0,94mH 4x0,1µF 4x18nF 3 Mounting stud F3737 400V 15A 1,4mA 1 3x0,45mH - 3x0,33µF + 3x0,47µF 15nF 1 Mounting stud F3380C 480V 16A 4,0mA 3 3x4,44mH 3x360µH 3x2,2µF + 3x1,0µF 3x35nF 6 Terminal screw F3738* 440V 20A 2,5mA 4 3x4,3mH 3x30µH 3x1,5µF + 3x0,74µF 3x15nF 5 Mounting stud F3297 480V 30A 3,0mA 7 4x0,67mH – 3x0,135µF + 3x0,135µF 4x10nF 4 Mounting stud F3297A 660V 30A 3,0mA 7 4x0,67mH – 3x0,75µF + 3x0,75µF 4x10nF 4 Mounting stud *Suitable for frequency converter applications Plastic incapsulated screw terminal (polyamide 6.6) for easy handling for wire sizes up to 4 mm (AWG 12) Leakage current line/ground at 250 V/50 Hz max. 3.4 mA/F3380-40 µA. Further versions with wire connections or combined with screw terminal on request. F2810/F3727 – 8 mounting studs No. 8-32 for fixed installation, 10 mounting studs with nut and washer No. 10-32 for cable connection. F3297A – 10 mounting studs with nut and washer. No. 10-32 for cable connection, 4 mounting straps for fixed installation (4x5.5 mm holes). Electrical Schematic Circuit No. 3 Circuit No. 1 Circuit No.2 Power line L L Power line L L Device Power line Device 2 1 L Device 1 2 1 PE N PE PE N PE PE PE Circuit No. 4 Circuit No. 5 Circuit No. 6 L L Power line L Device L 1 1 2 Power line L L Device Power line L Device 2 2 1 1 PE PE N PE PE N PE PE Circuit No. 7 Device Power line L 1 NN PE PE All specifications subject to change. Consult Tyco Electronics for latest design specifications. 77 Case Styles and typ. Sizes Case No. 1 Case No. 2 236,0 68,5 10,0±0,4 3,7x6,35 (x0,4) 8x32 14,0±0,4 42,5 10,0 95,2 M4 x 25 44,4±0,4 85,8 106,7 Hole M3 Phoenix VDFK4-DP 50,0 50,8 55,0 79,4 +0,8 +0,0 15,9 -1,8 19,0 -1,8 100,1 38,9 20,0 140,0 68,0 Case No. 3 Case No. 4 57,2 25,4 57,9 167 23,8 203,2 233,5 10±0,5 5,5±0,3 8±0,5 141,2 117,5 139,7 114,3 25,4 38,1 215 254,0 Typ. Insertion Loss asym. sym. dB dB dB 90 90 90 80 80 80 70 70 70 60 60 60 50 50 50 40 40 40 30 30 30 20 20 20 10 10 10 0 0 0 0,01 0,1 1 10 30 0,01 0,1 1 10 30 0,1 1 10 30 Frequency in MHz Frequency in MHz Frequency in MHz F3719 F3380 F3738 dB dB dB 90 90 90 80 80 80 70 70 70 60 60 60 50 50 50 40 40 40 30 30 30 20 20 20 10 10 10 0 0 0 0,01 0,1 1 10 30 0,1 1 10 30 0,01 0,1 1 10 30 Frequency in MHz Frequency in MHz Frequency in MHz F3737 F3380B F3727 dB dB 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 10 0 0 0,1 1 10 30 0,1 1 10 30 Frequency in MHz Frequency in MHz F2810 F3297/F3297A 78 All specifications subject to change. Consult Tyco Electronics for latest design specifications. Case Styles and typ. Sizes Case No. 5 50,0 260,0±0,8 25,0 95,0 120,0 60,0 ±0,8 25,0 Case No. 7 5,5 Dia (4x) 25,0 167 max 235,0 58 8x32 (7x) max 24,6 15 70,0 217 max 1/4x20 (2x) 287,0 211 Thickness 1,0 Case No. 6 240 max 214 8x32 (2x) 60 20 95,25 64 ±0,25 10 max 21 Phoenix 142 max VDFK4 (6x) Phoenix VDFK4 (8x) 246 187 Hole 10,5x5,5 (4x) 198,2±0,5 6,6 (4x) 15 159 145 129 max ±0,5 15 115±0,3 Thickness 1,0 148 Accessories for F2810 and F3727 Mounting bracket kit Mo. AA-400 (2 pieces) End bell kit No. AA-406 (2 pieces) All specifications subject to change. Consult Tyco Electronics for latest design specifications. 79 3-Phase Filters FCD-Series - Suitable to meet latest EMC standards (EN55011, -14, UL1283 and EN133200) - Designed for very noisy delta applications, e.g. frequency converters with long motor cables - Very high insertion loss - Low leakage currents - Shock protected screw-type terminal - Ideal for EMC-trouble shooting and EMC-refurbishing in the field - Nominal operating voltage 480V - Voltages up to 500V and beyond on request Type Operating Max. Max. Leakage current Inductance Capacity Type of voltage current voltage drop virtual LC C connection X Y AC 50/60Hz N to PE/V 2 6FCD10 480V 3x6A 0,26mA/V 4,62mH 2,2µF 0,7µF Terminal block 4mm 2 12FCD10 480V 3x12A 0,45mA/V 3,47mH 2,3µF 1,22µF Terminal block 4mm 2 16FCD10 480V 3x16A 0,45mA/V 3,46mH 2,3µF 1,22µF Terminal block 4mm 2 25FCD10 480V 3x25A 0,52mA/V 4,0mH 3,3µF 1,39µF Terminal block 6mm 2 36FCD10 480V 3x36A 0,52mA/V 1,7mH 3,3µF 1,39µF Terminal block 6mm 2 50FCD10 480V 3x50A 0,52mA/V 1,03mH 3,3µF 1,39µF Terminal block 10mm 2 12FCD10B 480V 3x12A 0,46mA/V 3,37mH 1,5µF 1,22µF Terminal block 4mm 2 16FCD10B 480V 3x16A 0,46mA/V 3,40mH 1,5µF 1,22µF Terminal block 4mm 2 25FCD10B 480V 3x25A 0,52mA/V 3,96mH 2,2µF 1,39µF Terminal block 6mm 2 36FCD10B 480V 3x36A 0,52mA/V 1,66mH 2,2µF 1,39µF Terminal block 6mm 2 50FCD10B 480V 3x50A 0,57mA/V 1,03mH 3,3µF 1,52µF Terminal block 10mm 2 80FCD10B 480V 3x80A 0,62mA/V 0,80mH 4,4µF 1,64µF Terminal block 50mm 2 110FCD10B 480V 3x110A 0,62mA/V 0,70mH 4,4µF 1,64µF Terminal block 50mm 2 150FCD10B 480V 3x150A 0,63mA/V 0,53mH 5,5µF 1,70µF Terminal block 50mm 2 150FCD10B-95 480V 3x150A 0,63mA/V 0,53mH 5,5µF 1,70µF Terminal block 95mm 2 180FCD10B 480V 3x180A 0,92mA/V 0,62mH 6,6µF 2,46µF Terminal block 95mm 2 200FCD10B 480V 3x200A 0,92mA/V 0,62mH 6,6µF 2,46µF Terminal block 95mm 2 230FCD10B 480V 3x230A 0,92mA/V 0,40mH 7,7µF 2,50µF Terminal block 95mm Earth-conductor-connection with threaded studs on each side Caution: Increased leakage current - please observe mounting instructions Electrical Schematic Device FCD10 Power line PE PE´ not with 6A FCD10B FCD10B 12A to 50A 80A to Device Power line Device Power line 230A PE PE´ PE PE´ 80 All specifications subject to change. Consult Tyco Electronics for latest design specifications. Case Styles and typ. Sizes 6FCD10 12FCD10 / 16FCD10/12FCD10B / 16FCD10B Phoenix VDFK4 (6x) Phoenix VDFK4 (6x) 0,6Nm max. torque Grounding 177 max 157 max M5 Screw 0,6Nm max. torque 8-32 Screw (2x) (2x) 59 65 max 40,1 47 21 max 21 10 58,4 max 10 149 170 9,9 (6) 6,6 20,6 6,6 (4x) (6) (4x) L L 15 L 40,1 L I O 80 15 LABEL I (2) 110 95 O N A max LABEL 15 109,2 140 125 N max ±0,5 A E D 15 max max ±,5 E D 111 max 10,9 (2) 47,2 (2) 70,0±0,3 70,0±0,3 131 max 151 max 25FCD10 / 36FCD10 / 50FCD10 80FCD10B / 110FCD10B / 150FCD10B 25FCD10B / 36FCD10B / 50FCD10B 25FCD10B 240 max Grounding M5 Screw (2x) 214 36/50FCD10B 141 Grounding max 10-32 Screw (2x) Phoenix VDFK6 (6x) 64 55 1,5Nm max. torque 33 31 50A: HDFK10 1,5Nm max. torque 246 307 6,6 (4x) 115±0,5 141 L L 15 168 56,5 O I LABEL 159 145 A N 15 max ±0,5 D E 155±0,5 129 max M10 6,6±0,2 Phoenix HDFK50 (6) 6Nm max. torque 34 221 max 115±0,3 148 150FCD10B-95 180FCD10B / 200FCD10B / 230FCD10B 141 141 max max 62,0 62,0 23,7 14,7 320 max 399 max 165±0,5 50 50 168 141 168 141 155±0,5 155±0,5 M10 M10 6,6±0,2 Phoenix HDFK95 (6x) 6,6±0,2 Phoenix HDFK95 (6x) 12Nm max. torque 34 221 max 34 12Nm max. torque 300 max All specifications subject to change. Consult Tyco Electronics for latest design specifications. 81 Typ. Insertion Loss asym. sym. dB dB dB 90 90 90 80 80 80 70 70 70 60 60 60 50 50 50 40 40 40 30 30 30 20 20 20 10 10 10 0 0 0 0,01 0,1 1 10 30 0,01 0,1 1 10 30 0,01 0,1 1 10 30 Frequency in MHz Frequency in MHz Frequency in MHz 12FCD10B 16FCD10B 6FCD10 dB dB dB 90 90 90 80 80 80 70 70 70 60 60 60 50 50 50 40 40 40 30 30 30 20 20 20 10 10 10 0 0 0 0,01 0,1 1 10 30 0,01 0,1 1 10 30 0,01 0,1 1 10 30 Frequency in MHz Frequency in MHz Frequency in MHz 25FCD10B 36FCD10B 12FCD10 dB dB dB 90 90 90 80 80 80 70 70 70 60 60 60 50 50 50 40 40 40 30 30 30 20 20 20 10 10 10 0 0 0 0,01 0,1 1 10 30 0,01 0,1 1 10 30 0,01 0,1 1 10 30 Frequency in MHz Frequency in MHz Frequency in MHz 50FCD10B 80FCD10B 16FCD10 dB dB dB 90 90 90 80 80 80 70 70 70 60 60 60 50 50 50 40 40 40 30 30 30 20 20 20 10 10 10 0 0 0 0,01 0,1 1 10 30 0,01 0,1 1 10 30 0,01 0,1 1 10 30 Frequency in MHz Frequency in MHz Frequency in MHz 110FCD10B 150FCD10B 25FCD10/36FCD10 dB dB dB 90 90 90 80 80 80 70 70 70 60 60 60 50 50 50 40 40 40 30 30 30 20 20 20 10 10 10 0 0 0 0,01 0,1 1 10 30 0,01 0,1 1 10 30 0,01 0,1 1 10 30 Frequency in MHz Frequency in MHz Frequency in MHz 230FCD10B 180FCD10B 50FCD10 200FCD10B 82 All specifications subject to change. Consult Tyco Electronics for latest design specifications. (pending) 3-Phase Filters FCD10BS-Series - Optimized for very high insertion loss - Suitable for infeed/regenerative- (ER)-modules Type Operating max. Max. Leakage current Inductance Capacity Type of connection voltage current voltage drop virtual LC C (both sides) X AC 50/60Hz N to PE/V 2 36FCD10BS 480V 3x36A 3,25mA/V 1,66mH 11µF 8,6µF Terminal block 16mm 2 50FCD10BS 480V 3x50A 3,25mA/V 1,03mH 11µF 8,6µF Terminal block 16mm 2 63FCD10BS 480V 3x63A 3,25mA/V 0,99mH 11µF 8,6µF Terminal block 16mm 2 80FCD10BS 480V 3x80A 3,25mA/V 0,8mH 11µF 8,6µF Terminal block 50mm 2 110FCD10BS 480V 3x110A 3,25mA/V 0,7mH 11µF 8,6µF Terminal block 50mm 2 150FCD10BS 480V 3x150A 3,25mA/V 0,53mH 11µF 8,6µF Terminal block 50mm 2 180FCD10BS 480V 3x180A 3,25mA/V 0,62mH 11µF 8,6µF Terminal block 95mm 2 230FCD10BS 480V 3x230A 3,25mA/V 0,4mH 11µF 8,6µF Terminal block 95mm Earth-conductor-connection with threaded studs on each side Caution: Increased leakage current - please observe mounting instructions Case Styles and typ. Sizes 36FCD10BS / 50FCD10BS / 63FCD10BS / 180FCD10BS / 230FCD10BS 80FCD10BS / 110FCD10BS / 150FCD10BS 400 max 308 max 300 max 221 max 141 max 74 ref 141 max 54 ref 62 ref 55 ref 25 ref 34 33 ref ref Phoenix HDFK95 (6x) 34 12Nm max torque Phoenix HDFK50 (6x) ref 6Nm max torque 165±0,5 115±0,5 L1 L1´ 168 25 L L 169 L1 L L1´ ref L ref 50 O max L2 I I L2´ 56,5 O 155±0,5 140 L2 ref L2´ A 140 N ref N max A D max E 155±0,5 L3 E L3´ 18,8 L3 L3´ D 18 ref 18 Ref Ground terminal M10x35 screw 6,6 ±0,2 6,6 ±0,2 Ground terminal M10x35 screw (2x) 20Nm max torque (2x) 10Nm max torque Electrical Schematic Typ. Insertion Loss asym. sym. dB Power line Device FCD10BS L1 L1´ 90 80 36A to 70 L2 L2´ 230A 60 50 L3 L3´ 40 30 20 10 0 0,01 0,1 1 10 30 PE PE´ Frequ. in MHz 80FCD10BS - 230FCD10BS All specifications subject to change. Consult Tyco Electronics for latest design specifications. 83 High Current Filter according IEC 950 CFN-Series - standard aluminium housing - suitable to meet UL1283, CSA, EN 133 200 - universal High-current-filter for industrial applications like frequency-converter, High current-driving-system, etc. - Delivered in three operating-voltages Type Operating- Leakage Type Operating- Leakage Type Operating- Leakage Operating voltage current voltage current voltage current current 50-60Hz 50Hz 50-60Hz 50Hz 50-60Hz 50Hz 300CFN12 480VAC 39mA 300CFN12H 520VAC 51mA 300CFN12HV 690VAC 60mA 300A 400CFN12 480VAC 39mA 400CFN12H 520VAC 51mA 400CFN12HV 690VAC 60mA 400A 500CFN12 480VAC 39mA 500CFN12H 520VAC 51mA 500CFN12HV 690VAC 60mA 500A 600CFN12 480VAC 39mA 600CFN12H 520VAC 51mA 600CFN12HV 690VAC 60mA 600A * Leakage current measured by IEC 1000-2-4 under normal orperating conditions. Are two phases disconnected, may be that the leakage current by unfavourable facts can reach the multiple of the value. Electrical Schematic Device Power line L1 L1« L2 L2« L3 L3« PE PE Typ. Insertion Loss asym. sym. Case Styles and typ. Sizes 630 564 100±0,5 3,0 dB L1 L1´ 90 100 L L O 275±0,5 80 300 I 250 120 L2 L2´ A N 220±0,5 70 E D L3 60 L3´ 50 PE PE 40 Hole for 30 Mounting brackets M5 (8x) 27 9 Dia (6x) 420±1 20 10 Screw M12 (2x) 0 30Nm max. torque 0,01 0,1 1 10 30 Copper-stick-terminal 30x8 160 (6x) 300CFN12 / 400CFN12 Frequency in MHz 500CFN12 / 600CFN12 10,5 Dia hole (6x) 64 516 84 All specifications subject to change. Consult Tyco Electronics for latest design specifications. (pending) 3-Phase Filters BCD-Series - Bookform with insolated safety terminals for input and output - Very high insertion loss - Ideal for EMC-trouble shooting and refurbishing in the field - Operating voltages over 480V AC available on request Type Operating Max. Max. leakage current Inductance Capacity Type of voltage current voltage drop virtual LC C connection X Y AC 50/60Hz N to PE/V 2 6BCD10 480V 3x6A 0,26mA/V 4,62mH 2,25µF 0,7µF Terminal block 4mm 2 12BCD10 480V 3x12A 0,45mA/V 3,46mH 2,25µF 1,2µF Terminal block 4mm 2 16BCD10 480V 3x16A 0,45mA/V 3,46mH 2,25µF 1,2µF Terminal block 6mm 2 25BCD10 480V 3x25A 0,52mA/V 4,0mH 3,3µF 1,38µF Terminal block 10mm 2 36BCD10 480V 3x36A 0,52mA/V 1,69mH 3,3µF 1,38µF Terminal block 10mm 2 50BCD10 480V 3x50A 0,52mA/V 1,03mH 3,3µF 1,38µF Terminal block 25mm 2 63BCD10 480V 3x63A 0,52mA/V 1,02mH 3,3µF 1,38µF Terminal block 25mm 2 80BCD10B 480V 3x80A 3,25mA/V 1,0mH 11µF 8,6µF Terminal block 50mm 2 110BCD10B 480V 3x110A 3,25mA/V 0,88mH 11µF 8,6µF Terminal block 50mm 2 130BCD10B 480V 3x130A 3,25mA/V 0,83mH 11µF 8,6µF Terminal block 50mm 2 150BCD10B 480V 3x150A 3,25mA/V 0,83mH 11µF 8,6µF Terminal block 50mm 2 180BCD10B 480V 3x180A 3,25mA/V 0,71mH 11µF 8,6µF Terminal block 95mm 2 230BCD10B 480V 3x230A 3,25mA/V 0,4mH 11µF 8,6µF Terminal block 95mm Earth-conductor-connection with threaded studs on each side; unless specified, tolerance to be ±0,5 Caution: Increased leakage current - please observe mounting instructions Case Styles and typ. Sizes 6BCD10 16BCD10 12BCD10 290 240 ±0,3 30 ±0,2 25 ±0,2 Phoenix VDFK 4 (6x) Phoenix VDFK 6 (6x) 0,6Nm max. torque 1,5Nm max. torque Thickness 1,0 Thickness 1,0 Grounding M5 (2x) Grounding M5 (2x) 5Nm max. torque 306 ref 5Nm max. torque 248 ref 30 275 225 30 ref LINE LOAD LOAD LINE 128 13 142 126 115 13 ref 95 ref ref ref 96 ref 79 85 ref 55 305 ref 50 255 ref 25BCD10 50BCD10 320 15 ref 314 ±0,3 36BCD10 63BCD10 L1 L1´ 58 L2 LINE LOAD L2´ 55 ±0,2 35 ref Phoenix HDFK 10 (6x) L3´ L3 1,5Nm max. torque Thickness 1,5 Phoenix HDFK 25 (6x) Thickness 1,0 Grounding M5 (2x) 4Nm max. torque 379 ref 5Nm max. torque Grounding M6 (2x) 5Nm max torque 30 305 300 ref LINE LOAD LINE LOAD 185 136 150 168 13 ref ref 119 ref 105 ref ref ref 90 98 80 330 ref 60 335 ref All specifications subject to change. Consult Tyco Electronics for latest design specifications. 85 Electrical Schematic BCD10 BCD10 6A 12A to 63A Device Power line Device Power line L1 L1« L1 L1« L2 L2« L2 L2« L3 L3« L3 L3« PE PE PE PE BCD10B 80A to 230A Device Power line L1 L1´ L2 L2´ L3 L3´ PE PE Case Styles and typ. Sizes 80BCD10B / 110BCD10B / 150BCD10B 130BCD10B 486 max Thickness 3,0 438 Max Thickness 1,5 L1´ L1 L1 L1´ 80 L2 LINE LOAD L2´ L2 LINE LOAD 65 L2´ Phoenix HDFK 50 (6x) L3 L3´ Phoenix HDFK 50 L3 L3´ 6Nm max. torque (6x) 6Nm max. torque 414 364 110 90 62 400 ref 62 350 Ref 54 ref LINE LOAD LINE LOAD 240 220 137 138 ref 106 Ref 116 Grounding M10 x 30 (2x) 440 max Grounding M10 x 30 (2x) 10Nm max. torque 380 Max 10Nm max. torque 501 max Thickness 3,0 180BCD10B L1 L1´ 230BCD10B 80 L2 LINE LOAD L2´ L3´ Phoenix HDFK 95(6x) L3 12Nm max. torque 414 110 75 400 ref 101 74 ref ref LINE LOAD 240 116 ref 100 Grounding M10 x 30 (2x) 440 max 12Nm max. torque 86 All specifications subject to change. Consult Tyco Electronics for latest design specifications. Typ. Insertion Loss asym. sym. dB dB 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 10 0 0 0,01 0,1 1 10 30 0,01 0,1 1 10 30 Frequ. in MHz Frequency in MHz 6BCD10 12BCD10/16BCD10/25BCD10 dB dB 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 10 0 0 0,01 0,1 1 10 30 0,01 0,1 1 10 30 Frequency in MHz Frequency in MHz 36BCD10 50BCD10 dB 90 80 70 60 50 40 30 20 10 0 0,01 0,1 1 10 30 Frequency in MHz 63BCD10 dB dB 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 10 0 0 0,01 0,1 1 10 30 0,01 0,1 1 10 30 Frequency in MHz Frequency in MHz 80BCD10B 110BCD10B dB dB 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 10 0 0 0,01 0,1 1 10 30 0,01 0,1 1 10 30 Frequ. in MHz Frequency in MHz 130BCD10B / 150BCD10B 180BCD10B / 230BCD10B All specifications subject to change. Consult Tyco Electronics for latest design specifications. 87 Line Filters for TEMPEST Applications AQ-Series - For commercial applications Tempest-Series - Standard and custom applications Type Max. current Max. Max. leakage current Additions voltage line to ground at 250 VAC/50 Hz 3VAQ3 3 A 250 VAC 2,3 mA 3VAQ8F 3 A 250 VAC 2,3 mA IEC connector and fuse holder 3VAQ8FS 3 A 250 VAC 2,3 mA IEC connector / fuse holder / switch 6VAQ3 6 A 250 VAC 1,2 mA — 6VAQ8F 6 A 250 VAC 1,2 mA IEC connector and fuse holder Electronic computing devices processing confidential infor- one device to the next. CORCOM TEMPEST filters provide mations must be protectet against misuse by unauthorized a very high conformity with the TEMPEST specifications. personnel. The most common standard in this respect is the This is accomplished by a filter design with extremely high TEMPEST specification issued by the U.S. Government. attenuation factors over the range from 10 kHz through 1 The same principle applies to all related equipment in the GHz for common as well as differential mode. Signals military, commercial or industrial field processing original or exceending this frequency range are mainly being radiated. encoded data. Filtering below 10 kHz is commonly unnecessary. Data, which have not been encoded, can easily be read out The stated performance features are being accomplished by either emission or propagation via power line. Availability by means of a multi-stage circuit and shielding in extension of highly sensitive receiving equipment is the only provision to a design for the observance of attenuation values in necessary. The available methods to prevent this are in switching power supplies in accordance with VDE level B. principle similar to those being utilized for interference The filters are hermetically sealed into metal cases and suppression in electronic equipment according to FCC or have been built in accordance with all applicable UL VDE standards. Radiated interference requires shielding, specifications. conducted interference requires line filtering. These standard filters can directly be used within a variety The concepts of power line filters for applications in accor- of applications without creating further design costs. For dance with TEMPEST specifications and those for common applications requiring further functions such as switches, power line interference suppression are of considerable power line plugs, fuses etc. different styles can on request difference. The actual TEMPEST specifications are easily be accomplished. For further advice we will be glad to confidential and the required attenuation factors vary from be at your service. Electrical Schematic 3A models 6A models 88 All specifications subject to change. Consult Tyco Electronics for latest design specifications. Case Style and typ. Sizes for Tempest Custom Applications 3VAQ8F 3VAQ8FS 41,2 41,2 151,4 160,1 10,4 Ref 10,4 Ref 6-32(6x) 6-32(6x) 13,2 40,0 I 40,0 63,0 24,4 63,0 ±0,4 O ±0,4 11,2 11,2 59,6 22,9 10,4 Ref 4,4 26,9 59,5 ±0,4 10,4 Ref ±0,4 128,6 ±0,4 136,9 ±0,4 3VAQ3 6VAQ8F 12,7±0,4 6,35±0,4 12,7 9,5 65,6 62,3 max 42,1 max 21,0 162,3 ±0,4 9,0 ±0,3 111,4±0,4 9,9 ±0,3 12,7±0,5 28,6 ±0,3 59,2 +0,4 40,1 max 78,0 19,8 105,1 max 101,6 ±0,4 9,0 ±0,3 11,3 ±0,3 144,3 ±0,4 6VAQ3 143,4 65,6 135,0 ±0,4 12,7 ±0,3 Recommended panel cutouts 78,0 50,8 ±0,4 33 18 23 22 16 Dia R 6 Fuse holder Power line switch IEC connector 130,3 Inserts and studs: 6-32 Wire leads: 300 min. Typ. Insertion Loss asym. sym. dB dB 100 100 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 10 0 0 0,01 0,1 1 10 100 1000 0,01 0,1 1 10 100 1000 6A models 3A models All specifications subject to change. Consult Tyco Electronics for latest design specifications. 89 CORCOM – Your Partner for RFI Solutions ™ Filtered Modular Jack Space saving and cost effective device for interference elimination in signal lines. L and C components integrated in plug- in space. Available in three sizes and pole numbers 2-4-6-8. Can optionally be shipped with shielding with/without ground spring. Separate catalogue on request. L-Models Inductive filtering in a direct retrofit to standard, unfiltered jacks. Both L and LC models are offered with standard ferrite sleeve (or higher performance ferrite block) inductors for RJ11 and RJ45 style jacks. Shielded L-Models LC-Models Inductance filtering with the ad- Capacitance components ditional metal shield. The shield enhance the filtering performance is available with RFI gasket style in the LC models. Available with spring fingers to provide a low block or sleeve inductance, all impedance ground path across models are shielded for additional the interface. protection. N-Models Low profile RJ jacks BLF-Series Surface mountable RFI filters RJH-Models A direct retrofit to handset connectors, the RJH models feature block inductance for op- timal filtering of up to four lines. NEW Ganged Version: 2 RJ11 - 6 LB 4 RJ11 - 6 LB 6 RJ11 - 6 LB X-Models Standard, unfiltered jacks to complement our filtered models. 90 All specifications subject to change. Consult Tyco Electronics for latest design specifications. ™ Surface mountable RFI filters BLF-Series Type Max. current Capacity Inductance This line of surface mountable RFI filters is specifically UL, VDE designed to eliminate noise on the signal line. These board level filters attenuate noise on the signal line at the frequency BLF082 1A 82pF 2µH range of 10MHz to 1000MHz with maximum attenuation at BLF820 1A 820pF 2µH 40MHz to 400MHz. the filter performance by combining the elements into one The U shaped ferrite features a parallel first and second leg low profile single piece filter. Each filter acts on two signal with a center leg surrounded by a grounding/shorting strap lines, but can be stacked an an array to allow performance and a capacitor for each line. This unique design optimizes over multiple lines. Electrical Schematic The BLF filter can withstand dielectric voltage of 1000VAC for 60 seconds, thereby allowing placement of this filter at the optimal location, immediately behind the connector. This placement allows immunity protection from signal line interference as well as significant reduction of RFI emissions. Power Device line The filter can be used in conjunction with unfiltered RJ jacks, ganged jacks, or with filtered modular jacks for additional protection. Typ. Insertion Loss asym. Case Styles and typical Sizes dB 6,35 max 11,43 max 40 30 9,52 max 20 10 2,54 0 1 10 100 1000 Frequency in MHz 6,73 BLF082 PC Board 2,54 Layout dB 40 Gnd Pad 30 3,81 20 1,19 3,04 10 min. 1,19 min. 0 1,27 1 10 100 1000 Frequency in MHz BLF820 All specifications subject to change. Consult Tyco Electronics for latest design specifications. 91 Cross Reference List Corcom PN Tyco PN Corcom PN Tyco PN Corcom PN Tyco PN Corcom PN Tyco PN 100ADT6 0-1609071-4 1EGG8C-2 0-1609115-9 10MV1 0-1609056-3 15DCF10 1-1609074-1 100ADT6-S 0-1609071-3 10R1 0-1609030-5 15DCF10B 1-1609074-2 1EGS1-1 0-1609117-1 100AYA6A 0-1609977-7 10R6 0-1609030-6 15DCF6 0-1609074-1 1EGS1-2 0-1609117-2 100AYO6 0-1609972-2 10VB1 0-1609021-9 15DCF6B 0-1609074-2 1EHG1-2 0-1609116-1 100DCB10 5-1609074-3 10VB3 1-1609021-0 15ED1 1-1609016-8 1EK1 0-1609027-1 100DCB10B 5-1609074-5 10VB6 1-1609021-2 15EF1F 0-1609015-9 1EK3 0-1609027-2 100DCB10BF 5-1609074-6 10VDK1 0-1609034-7 15EHT1 1-1609053-1 1EOP 0-1609064-1 100DCB10F 5-1609074-4 10VDK3 0-1609034-8 15EHT6 1-1609053-2 1ER1 0-1609031-1 100DCB6 3-1609074-3 10VG1 0-1609051-2 15ET1 0-1609046-9 1ER3 0-1609031-2 100DCB6B 3-1609074-5 10VK1 1-1609028-3 15ET6 1-1609046-0 1EZP 0-1609062-1 100DCB6BF 3-1609074-6 1IK1C 1-1609085-1 10VK3 1-1609028-4 15VT1 0-1609047-3 100DCB6F 3-1609074-4 10VK6 1-1609028-8 15VT6 0-1609047-4 1K1 0-1609026-1 100DCF10 1-1609074-7 10VK7 1-1609028-5 160ADT6 0-1609071-6 1R1 0-1609030-1 100DCF10B 1-1609074-8 10VK7L 5-1609087-3 160ADT6-S 0-1609071-5 1VB1 0-1609021-1 100DCF6 0-1609074-7 10VK7M 1-1609028-6 16AYA10 0-1609977-1 1VB3 0-1609021-2 100DCF6B 0-1609074-8 10VN1 0-1609052-2 16AYA6 0-1609068-1 1VDK1 0-1609034-1 10AYO1 0-1609066-3 10VR1 1-1609032-3 16AYA6A 0-1609068-2 1VDK3 0-1609034-2 10B1 0-1609019-5 10VR3 1-1609032-4 16AYC10B 0-1609067-1 1VK1 0-1609028-1 10CE1 0-1609112-3 10VR6 1-1609032-5 16BCD10 1-1609979-2 1VK3 0-1609028-2 10CFE1 1-1609113-3 10VR7 1-1609032-6 16FC10 0-1609069-3 1VR1 0-1609032-1 10CFS1 1-1609113-4 1VR3 0-1609032-2 10VR7M 1-1609032-7 16FC10B 0-1609976-1 10CHE1 1-1609114-3 10VS1 0-1609042-3 16FCD10 0-1609070-3 200ADT6 0-1609071-8 10CHS1 1-1609114-4 10VSK1 0-1609036-9 16FCD10A 3-1609974-4 200ADT6-S 0-1609071-7 10CS1 0-1609112-8 10VSK3 1-1609036-0 16FCD10B 0-1609974-5 200AYC10B 0-1609067-8 10DAF1 0-1609075-8 10VSK7 1-1609036-1 16IK10 0-1609973-1 200FCD10B 1-1609070-1 10DAFP 0-1609075-7 10VSK7M 1-1609036-2 180AYC10B 0-1609977-6 20AYO1 0-1609066-4 10EAH1 0-1609002-5 10VSP1 8-1609082-7 180BCD10B 0-1609979-4 20AYP6C 0-1609072-1 10EAS1 0-1609004-4 10VT1 0-1609047-1 180FCD10B 1-1609070-0 20AYT6C 0-1609073-1 10EB1 0-1609020-9 10VT3 0-1609047-2 180FCD10BS 2-1609974-1 20B6 0-1609019-8 10EB3 1-1609020-0 10VV1 0-1609043-3 1B1 0-1609019-1 20EB1 1-1609020-1 10EBF1 0-1609018-7 20EDK1 0-1609033-9 10VW1 0-1609044-3 1CFE1 0-1609113-1 10EBF4 0-1609018-8 10W1 0-1609041-3 1CFS1 0-1609113-2 20EK1 1-1609027-7 10EBH1 0-1609003-4 110AYC10B 0-1609067-5 1CHE1 0-1609114-1 20EP1 0-1609037-9 10EBS1 0-1609005-4 110BCD10B 0-1609979-3 1CHS1 0-1609114-2 20EP6 1-1609037-0 10EC1 1-1609017-3 110FCD10B 0-1609070-8 1EAH1 0-1609002-1 20EQ1 0-1609048-9 10ED1 1-1609016-6 110FCD10BS 1-1609974-8 1EAS1 0-1609004-1 20ER1 1-1609031-7 10ED1C 1-1609016-7 125DCB10 5-1609074-7 1EB1 0-1609020-1 20ESK1 7-1609971-6 10EDK1 0-1609033-7 125DCB10B 5-1609074-9 1EB3 0-1609020-2 20ESK6 1-1609035-3 10EDK3 0-1609033-8 125DCB10BF 6-1609074-0 1EBF1 0-1609018-1 20ET1 1-1609046-1 10EDP 0-1609065-4 125DCB10F 5-1609074-8 1EBF4 0-1609018-2 20ET6 1-1609046-2 10EEA1 1-1609000-0 20K6 0-1609026-8 125DCB6 3-1609074-7 1EBH1 0-1609003-1 10EEA2 1-1609000-1 125DCB6B 3-1609074-9 1EBP 0-1609063-1 20MV1 0-1609056-4 10EEAP 1-1609000-2 125DCB6BF 4-1609074-0 1EBS1 0-1609005-1 20R6 0-1609030-8 10EEB1 1-1609001-0 125DCB6F 3-1609074-8 1EC1 0-1609017-1 20VB1 1-1609021-1 10EEB2 1-1609001-1 125DCF10 1-1609074-9 1EC2 0-1609017-2 20VB6 1-1609021-3 10EEBP 1-1609001-2 125DCF10B 2-1609074-0 1EC4 0-1609017-3 20VDK1 0-1609034-9 10EF1F 0-1609015-7 125DCF6 0-1609074-9 1EC8 0-1609017-4 20VDK6 1-1609034-0 10EF1FC 0-1609015-8 125DCF6B 1-1609074-0 1ED1 0-1609016-1 20VK1 1-1609028-7 10EG1 0-1609050-2 12BCD10 0-1609979-8 1ED2 0-1609016-2 20VK6 1-1609028-9 10EH1 0-1609012-5 12FC10 0-1609069-2 1ED4 0-1609016-3 20VK7 2-1609028-2 10EH3 0-1609012-6 20VP1 0-1609038-1 12FC10B 0-1609976-3 1ED8 0-1609016-4 10EH4 0-1609013-5 12FCD10 0-1609070-2 1EDK1 0-1609033-1 20VP6 0-1609038-2 10EH4C 0-1609013-6 12FCD10A 0-1609974-3 1EDK3 0-1609033-2 20VQ1 0-1609049-5 10EHT1 0-1609053-9 12FCD10B 0-1609974-4 1EDP 0-1609065-1 20VR1 1-1609032-8 10EHT3 1-1609053-0 130BCD10B 0-1609979-9 1EEA1 0-1609000-1 20VR6 1-1609032-9 10EK1 1-1609027-3 14EQ8 1-1609083-5 1EEA2 0-1609000-2 20VS1 0-1609042-4 10EK3 1-1609027-4 150AYC10B 0-1609067-6 1EEAP 0-1609000-3 20VS6 0-1609042-5 10EK7 1-1609027-5 150AYC10B-95 0-1609067-7 1EEB1 0-1609001-1 20VSK6 1-1609036-3 10EK7M 1-1609027-6 150BCD10B 1-1609979-0 1EEB2 0-1609001-2 20VT1 0-1609047-5 10EOP 0-1609064-4 150BCD10B-95 1-1609979-1 1EEBP 0-1609001-3 20VT6 0-1609047-6 10EP1 0-1609037-7 20VV1 0-1609043-4 150FCD10B 0-1609070-9 1EEC1 0-1609076-1 10EP3 0-1609037-8 150FCD10B-95 3-1609974-3 1EF1 0-1609014-1 20VV6 0-1609043-5 10ER1 1-1609031-3 150FCD10BS 2-1609974-0 1EF1F 0-1609015-1 20VW1 0-1609044-4 10ER1C 7-1609087-1 150FCD10BS-95 1-1609974-9 1EF2 0-1609014-2 20VW6 0-1609044-5 10ER3 1-1609031-4 15DAF1 1-1609075-0 1EF2F 0-1609015-2 20VW7 0-1609044-6 10ER7 1-1609031-5 15DAFP 0-1609075-9 1EF4 0-1609014-3 230BCD10B 1-1609979-3 10ER7M 1-1609031-6 15DCB10 4-1609074-1 1EF8 0-1609014-4 230FCD10B 1-1609070-2 10ESK1 0-1609035-9 15DCB10B 4-1609074-3 1EGG1-1 0-1609115-1 230FCD10BS 3-1609974-6 10ESK3 1-1609035-0 15DCB10BF 4-1609074-4 1EGG1-2 0-1609115-3 250ADT6 1-1609071-0 10ESK7 1-1609035-1 15DCB10F 4-1609074-2 1EGG1C-1 0-1609115-4 25AYA6 0-1609068-3 10ESK7M 1-1609035-2 25AYA6A 0-1609977-2 15DCB6 2-1609074-1 1EGG1C-2 0-1609115-5 10ET1 0-1609046-7 15DCB6B 2-1609074-3 1EGG8-1 0-1609115-6 25AYC10B 0-1609068-4 10ET3 0-1609046-8 15DCB6BF 2-1609074-4 1EGG8-2 0-1609115-7 25BCD10 1-1609979-4 10K6 0-1609026-6 15DCB6F 2-1609074-2 1EGG8C-1 0-1609115-8 25FC10 0-1609069-4 92 All specifications subject to change. Consult Tyco Electronics for latest design specifications. Corcom PN Tyco PN Corcom PN Tyco PN Corcom PN Tyco PN Corcom PN Tyco PN 25FC10B 0-1609976-2 3DAF1 0-1609075-4 3ESK3 0-1609035-2 4EDL4CM-32 0-1609980-8 25FCD10 0-1609070-4 3DAFP 0-1609075-3 3ESK7 0-1609035-3 4EDL4M 1-1609122-8 25FCD10B 0-1609974-9 3EAH1 0-1609002-2 3ESK7M 0-1609035-4 4EXP 0-1609060-4 2B1 0-1609019-2 3EAS1 0-1609004-2 3ET1 0-1609046-1 4EYP 0-1609061-4 2EB1 0-1609020-3 3EB1 0-1609020-5 3ET3 0-1609046-2 4RJ11-6LB 0-1609213-1 2EB3 0-1609020-4 3EB3 0-1609020-6 3ET7 0-1609046-3 500CFN12 0-1609978-3 2EDL1S 0-1609122-1 3EBF1 0-1609018-3 3EX1 0-1609059-1 500CFN12S 0-1609978-8 2EDL1S-01 0-1609980-5 3EBF4 0-1609018-4 3EXLA2S 0-1609119-1 50AYA6 0-1609068-7 2EDL1SC 0-1609122-2 3EBH1 0-1609003-2 3EXM1S 0-1609131-1 50AYA6A 0-1609068-8 2EDL1SCM 0-1609122-3 3EBP 0-1609063-2 3EXM4 0-1609131-2 50AYO6 0-1609972-1 2EDL1SM 0-1609122-4 3EBS1 0-1609005-2 3EXM4S 0-1609131-3 50BCD10 0-1609979-1 2EDL4 0-1609122-5 3EC1 0-1609017-5 3EXM4SE 0-1609980-1 50FC10 0-1609069-6 2EDL4-11 0-1609122-6 3EC2 0-1609017-6 3EXP 0-1609060-3 50FC10B 0-1609069-7 2EDL4-21 0-1609980-3 3EC4 0-1609017-7 3EYP 0-1609061-3 50FCD10 0-1609070-6 2EDL4-31 0-1609980-4 3EC8 0-1609017-8 3EZ1 0-1609059-2 50FCD10B 1-1609974-3 2EDL4C 0-1609122-7 3ED1 0-1609016-5 3EZLA2S 0-1609120-1 50FCD10BS 1-1609974-6 2EDL4CM 0-1609122-9 3ED2 0-1609016-6 3EZM1S 0-1609132-1 50IK10 0-1609973-5 2EDL4M 1-1609122-0 3ED4 0-1609016-7 3EZM4 0-1609132-2 5B1 0-1609019-4 2EDL4M-32 0-1609980-9 3ED8 0-1609016-8 3EZM4S 0-1609132-3 5EB1 0-1609020-7 2EK1 0-1609027-3 3EDK1 0-1609033-3 3EZM4SE 0-1609980-2 5EB3 0-1609020-8 2EK3 0-1609027-4 3EDK3 0-1609033-4 3EZP 0-1609062-3 5EDM4S 0-1609148-1 2ER1 0-1609031-3 3EDP 0-1609065-2 3K1 0-1609026-3 5EFLA2S 0-1609118-1 2ER3 0-1609031-4 3EEA1 0-1609000-4 3MV1 0-1609056-1 5EFM1 0-1609129-1 2EYP 0-1609061-2 3EEA2 0-1609000-5 3R1 0-1609030-3 5EFM1C 0-1609129-2 2EZP 0-1609062-2 3EEAP 0-1609000-6 3VAQ3 0-1609057-1 5EFM1S 0-1609129-4 2K1 0-1609026-2 3EEB1 0-1609001-4 3VAQ8F 0-1609058-1 5EFM1SC 0-1609129-5 2R1 0-1609030-2 3EEB2 0-1609001-5 3VAQ8FG 0-1609058-6 5EFM1SE 0-1609129-3 2RJ11-6LB 3-1609208-6 3EEBP 0-1609001-6 3VAQ8FS 0-1609058-2 5EFM4 0-1609129-6 2VB1 0-1609021-3 3EEC1 0-1609076-2 3VAQ8FSG 0-1609058-7 5EFM4C 0-1609129-7 2VB3 0-1609021-4 3EF1 0-1609014-5 3VB1 0-1609021-5 5EFM4E 1-1609088-0 2VK1 0-1609028-3 3EF1F 0-1609015-3 3VB3 0-1609021-6 5EFM4S 0-1609129-9 2VK3 0-1609028-4 3EF2 0-1609014-6 3VDK1 0-1609034-3 5EFM4SC 1-1609129-0 2VR1 0-1609032-3 3EF2F 0-1609015-4 3VDK3 0-1609034-4 5EFM4SE 0-1609129-8 2VR3 0-1609032-4 3EF4 0-1609014-7 3VK1 0-1609028-5 5EHM1 0-1609130-1 300ADT6 0-1609975-1 3EF8 0-1609014-8 3VK3 0-1609028-6 5EHM1E 6-1609088-6 300CFN12 0-1609978-1 3EF8C 1-1609093-6 3VK7 0-1609028-7 5EHM1S 0-1609130-2 300CFN12S 0-1609978-6 3EGG1-1 1-1609115-1 3VK7M 0-1609028-8 5EHM1SE 1-1609980-0 30AYP6C 0-1609072-2 3EGG1-2 1-1609115-2 3VQ1 0-1609049-1 5EHM4 0-1609130-3 30AYT6C 0-1609073-2 3EGG1C-1 1-1609115-3 3VQ3 0-1609049-2 5EHM4E 1-1609980-1 30B6 0-1609019-9 3EGG1C-2 1-1609115-5 3VQ8 0-1609049-3 5EHM4S 0-1609130-4 30DCB10 4-1609074-5 3EGG8-2 1-1609115-8 3VQ8M 0-1609049-4 5EHM4SE 6-1609088-8 30DCB10B 4-1609074-7 3EGG8C-1 1-1609115-9 3VR1 0-1609032-5 5EK1 0-1609027-9 30DCB10BF 4-1609074-8 3EGG8C-2 2-1609115-0 3VR3 0-1609032-6 5EK3 1-1609027-0 30DCB10F 4-1609074-6 3EGS1-1 0-1609117-3 3VR7 0-1609032-7 5EK7 1-1609027-1 30DCB6 2-1609074-5 3EGS1-2 0-1609117-4 3VR7M 0-1609032-8 5ER1 0-1609031-9 30DCB6B 2-1609074-7 3EH1 0-1609012-1 3VS1 0-1609042-1 5ER3 1-1609031-0 30DCB6BF 2-1609074-8 3EH3 0-1609012-2 3VSK1 0-1609036-1 5ER7 1-1609031-1 30DCB6F 2-1609074-6 3EHG1-2 0-1609116-2 3VSK3 0-1609036-2 5ER7M 1-1609031-2 30DCF10 1-1609074-3 3EHQ1 0-1609054-1 3VSK7 0-1609036-3 5K1 0-1609026-4 30DCF10B 1-1609074-4 3EHQ3 0-1609054-2 3VSK7M 0-1609036-4 5R1 0-1609030-4 30DCF6 0-1609074-3 3EHQ8 0-1609054-3 3VV1 0-1609043-1 5VB1 0-1609021-7 30DCF6B 0-1609074-4 3EHQ8M 0-1609054-4 3VW1 0-1609044-1 5VB3 0-1609021-8 30ESK6 1-1609035-4 3EHT1 0-1609053-1 400CFN12 0-1609978-2 5VK1 0-1609028-9 30ESK6C 1-1609035-5 3EHT3 0-1609053-2 400CFN12S 0-1609978-7 5VK3 1-1609028-0 30K6 0-1609026-9 3EHT7 0-1609053-3 40VK6 2-1609028-3 5VK7 1-1609028-1 30VB6 1-1609021-4 3EHT7M 0-1609053-4 40VK6C 2-1609028-4 5VK7M 1-1609028-2 30VK6 2-1609028-0 3EHZ1 0-1609055-1 40VSK6 1-1609036-6 5VR1 0-1609032-9 30VK6C 2-1609028-1 3EK1 0-1609027-5 41-3090-AO 4-1609218-1 5VR3 1-1609032-0 30VSK6 1-1609036-4 3EK3 0-1609027-6 41-3113-AO 4-1609219-1 5VR7 1-1609032-1 30VSK6C 1-1609036-5 3EK7 0-1609027-7 41-3114-AO 4-1609220-1 5VR7M 1-1609032-2 35IK10 0-1609973-2 3EK7M 0-1609027-8 41-3115-AO 4-1609221-1 6,5VR1 7-1609087-4 36AYA10 0-1609068-6 3EOP 0-1609064-2 41-3116-AO 4-1609222-1 600CFN12 0-1609978-4 36AYA6 0-1609068-5 3EP1 0-1609037-1 41-3150-AA 4-1609223-1 600CFN12S 0-1609978-9 36AYA6A 0-1609977-3 3EP3 0-1609037-2 41-3150-AO 4-1609224-1 60AYP6C 0-1609072-4 36AYC10B 0-1609067-2 3EP7 0-1609037-3 41-3151-AO 4-1609225-1 60AYT6C 0-1609073-4 36BCD10 1-1609979-5 3EP7M 0-1609037-4 41-3421-AO 4-1609229-1 60DCB10 4-1609074-9 36FC10 0-1609069-5 3EQ1 0-1609048-1 45AYP6C 0-1609072-3 60DCB10B 5-1609074-1 36FC10B 0-1609976-4 3EQ3 0-1609048-2 45AYT6C 0-1609073-3 60DCB10BF 5-1609074-2 36FCD10 0-1609070-5 3EQ8 0-1609048-3 4EDL1S 1-1609122-1 60DCB10F 5-1609074-0 36FCD10B 1-1609974-1 3EQ8M 0-1609048-4 4EDL1SC 1-1609122-2 60DCB6 2-1609074-9 3AYO1 0-1609066-1 3ER1 0-1609031-5 4EDL1SCM 1-1609122-3 60DCB6B 3-1609074-1 3B1 0-1609019-3 3ER1C 6-1609087-9 4EDL1SM 1-1609122-4 60DCB6BF 3-1609074-2 3CFE1 0-1609113-5 3ER3 0-1609031-6 4EDL4 1-1609122-5 60DCB6F 3-1609074-0 3CFS1 0-1609113-6 3ER7 0-1609031-7 4EDL4C 1-1609122-6 60DCF10 1-1609074-5 3CHE1 0-1609114-5 3ER7M 0-1609031-8 4EDL4C-21 0-1609980-6 60DCF10B 1-1609074-6 3CHS1 0-1609114-6 3ESK1 0-1609035-1 4EDL4CM 1-1609122-7 60DCF6 0-1609074-5 All specifications subject to change. Consult Tyco Electronics for latest design specifications. 93 Corcom PN Tyco PN Corcom PN Tyco PN Corcom PN Tyco PN Corcom PN Tyco PN 60DCF6B 0-1609074-6 6EH8 0-1609013-3 6VM4SC 1-1609128-3 F-3426 6-1609083-3 60VB6 4-1609086-0 6EH9 0-1609013-2 6VM4SE 1-1609128-1 F-3426B 6-1609083-4 63ADT6 0-1609071-2 6EHG1-2 0-1609116-3 6VN1 0-1609052-1 F-3550 2-1609093-0 63ADT6-S 0-1609071-1 6EHL1S 0-1609123-1 6VS1 0-1609042-2 F-3558 1-1609084-5 63AYA10 0-1609977-5 6EHL1SC 0-1609123-2 6VSK1 0-1609036-5 F-3719 7-1609084-3 63AYA6 0-1609977-4 6EHL1SCM 0-1609123-3 6VSK3 0-1609036-6 F-3737 8-1609084-2 63AYA6A 0-1609977-8 6EHL1SM 0-1609123-4 6VSK7 0-1609036-7 F-3738 8-1609084-3 63AYC10B 0-1609067-3 6EHL4 0-1609123-5 6VSK7M 0-1609036-8 G-0110 0-1609300-6 63BCD10 0-1609979-2 6EHL4C 0-1609123-6 6VV1 0-1609043-2 G-0111 0-1609301-6 6AYO1 0-1609066-2 6EHL4CM 0-1609123-7 6VW1 0-1609044-2 G-0112 0-1609302-6 6BCD10 0-1609979-6 6EHL4M 0-1609123-8 700CFN12 1-1609978-0 G-0114 0-1609303-6 6CFE1 0-1609113-9 6EHL4M-32 0-1609123-9 700CFN12S 1-1609978-1 G-0127 0-1609318-6 6CFS1 1-1609113-0 6EHQ1 0-1609054-5 70-1470 0-1609143-2 GA210 0-1609136-1 6CHE1 0-1609114-9 6EHQ3 0-1609054-6 7EQ1 7-1609971-5 GA310 0-1609136-2 6CHS1 1-1609114-0 6EHQ8 0-1609054-7 800CFN12 1-1609978-2 HPF300CTF 2-1609092-2 6DAF1 0-1609075-6 6EHQ8M 0-1609054-8 800CFN12S 1-1609978-3 JA-302 0-1609143-1 6DAFP 0-1609075-5 6EHT1 0-1609053-5 80-1245 0-1609142-1 JA-400 0-1609137-1 6EAH1 0-1609002-3 6EHT3 0-1609053-6 80AYC10B 0-1609067-4 JA-401 0-1609137-2 6EAS1 0-1609004-3 6EHT7 0-1609053-7 80BCD10 1-1609979-6 JA-403 0-1609137-3 6EBF1 0-1609018-5 6EHT7M 0-1609053-8 80BCD10B 0-1609979-5 MA-100 0-1609139-1 6EBF4 0-1609018-6 6EL1S 0-1609121-1 80FCD10B 0-1609070-7 MA-101 0-1609139-2 6EBG1-1 3-1609115-2 6EL1SC 0-1609121-2 80FCD10BS 1-1609974-7 MA-102 0-1609145-1 6EBH1 0-1609003-3 6EL1SM 0-1609121-4 80IK10 0-1609973-3 MA-103 0-1609145-2 6EBP 0-1609970-9 6EL4 0-1609121-5 85-1500 0-1609137-4 MA-104 0-1609145-3 6EBS1 0-1609005-3 6EL4C 0-1609121-6 8BCD10 0-1609979-7 MA-1200 0-1609139-3 6EC1 0-1609017-9 6EL4CM 0-1609121-7 900CFN12 0-1609978-5 MA-1201 7-1609297-2 6EC2 1-1609017-0 6EOP 0-1609064-3 900CFN12S 1-1609978-4 MA-302 0-1609145-4 6EC4 1-1609017-1 6EP1 0-1609037-5 AA-400 0-1609080-1 MA-304 0-1609145-5 6EC8 1-1609017-2 6EP3 0-1609037-6 AA-405 0-1609080-6 MA-400 0-1609139-4 6ECJ4 0-1609127-5 6EQ1 0-1609048-5 AA-406 0-1609080-7 NF10431-12 2-1609092-3 6ED1 0-1609016-9 6EQ3 0-1609048-6 AA-406A 0-1609970-1 NF21590 0-1609194-5 6ED1C 1-1609016-1 6EQ8 0-1609048-7 AA-407 0-1609080-8 NF21593-3 0-1609194-8 6ED2 1-1609016-0 6EQ8M 0-1609048-8 AA-407A 0-1609970-2 NFR543 7-1609202-4 6ED4 1-1609016-2 6ER1C 7-1609087-0 AA-500A 0-1609970-3 PA100 0-1609140-1 6ED4C 1-1609016-4 6ESK1 0-1609035-5 AA-501A 0-1609970-4 PA101 0-1609146-1 6ED8 1-1609016-3 6ESK3 0-1609035-6 AA-502A 0-1609970-5 PA102 0-1609146-2 6ED8C 1-1609016-5 6ESK7 0-1609035-7 AA-506 0-1609970-6 PA105 0-1609140-3 6EDK1 0-1609033-5 6ESK7M 0-1609035-8 AA-507 0-1609970-7 PA200 0-1609140-4 6EDK3 0-1609033-6 6ESRFC3 0-1609133-2 AA-510 0-1609970-8 PA400 0-1609146-3 6EDL1S 1-1609122-9 6ESRMC2 0-1609133-4 APF300CEE 1-1609092-9 PA410 0-1609146-4 6EDL1SC 2-1609122-0 6ET1 0-1609046-4 APF331W 0-1609092-6 PA420 0-1609146-5 6EDL1SCM 2-1609122-1 6ET3 0-1609046-5 APF600CEE 2-1609092-0 PE000DD3D 0-1609110-1 6EDL1SM 2-1609122-2 6ET7 0-1609046-6 APF600CET 2-1609092-1 PE000DD6D 0-1609110-3 6EDL4 2-1609122-3 6EU1 0-1609045-2 APFV2031L 1-1609092-1 PE000DDXD 0-1609110-5 6EDL4C 2-1609122-4 6EUP 0-1609045-1 BLF082 0-1609207-1 PE000DS6A 8-1609930-3 6EDL4CM 2-1609122-5 6EXP 0-1609060-6 BLF820 0-1609207-2 PE000DSXA 7-1609930-7 6EDL4M 2-1609122-6 6FC10 0-1609069-1 CDEFX400025B6 1-1609163-9 PE000SD3D 0-1609110-2 6EDL4M-32 0-1609980-7 6FCD10 0-1609070-1 CDEUL400010B6 3-1609166-2 PE000SD6D 0-1609110-4 6EDP 0-1609065-3 6FCD10A 0-1609974-2 CDEUX400030B6 2-1609172-0 PE000SDXD 0-1609110-6 6EEA1 0-1609000-7 6HJ4-4 0-1609126-2 CDEUX400060B6 2-1609172-1 PE000SS30 0-1609104-8 6EEA2 0-1609000-8 6IK1 0-1609973-4 CDEUX400100B6 3-1609172-2 PE000SS3B 0-1609931-2 6EEAP 0-1609000-9 6J4 0-1609125-1 CDEUX400300B6 2-1609172-6 PE000SS6B 0-1609931-5 6EEB1 0-1609001-7 6J4-2 0-1609125-2 CDFS 1004-A 0-1609192-1 PE000SSX0 0-1609104-6 6EEB2 0-1609001-8 6MV1 0-1609056-2 CDFS 1028 0-1609195-1 PE00SD000 0-1609100-3 6EEBP 0-1609001-9 6RJ11-6LB 0-1609213-2 CDFS 1030 0-1609193-1 PE00SDH60 8-1609929-5 6EEC1 0-1609076-3 6SP1A 1-1609088-3 CDFS 1038 5-1609192-4 PE00SDHXB 7-1609929-6 6EF1 0-1609014-9 6V1 0-1609040-2 CDFS 1043 0-1609194-2 PE00SSS3B 1-1609930-5 6EF1F 0-1609015-5 6VAQ3 0-1609057-3 CDFS 1044 0-1609194-3 PE00SSS60 0-1609104-3 6EF2 1-1609014-0 6VAQ3G 0-1609057-4 CDSRW1050B6-C 2-1609182-4 PE00SSS6A 1-1609930-8 6EF2F 0-1609015-6 6VAQ8F 0-1609058-3 CDSRW2005B6-E 3-1609183-6 PE00XD000 2-1609956-2 6EF4 1-1609014-1 6VAQ8FG 0-1609058-8 CDSRW2030B6-E 3-1609183-9 PE00XDS3B 3-1609930-8 6EF8 1-1609014-2 6VDK1 0-1609034-5 CDSRW2050B6-E 4-1609183-0 PE00XDS60 1-1609104-8 6EG1 0-1609050-1 6VDK3 0-1609034-6 CDSRX1005B6-E 0-1609185-7 PE00XDS6A 4-1609930-1 6EGG1-1 2-1609115-2 6VG1 0-1609051-1 CDSRX1025B6-E 0-1609185-8 PE00XSS3B 6-1609930-1 6EGG1-2 2-1609115-3 6VJ1 0-1609124-1 CDSRX1200B6-E 1-1609185-1 PE00XSS60 0-1609104-2 6EGG1C-1 2-1609115-4 6VJ1-2 0-1609124-2 CDSRX1400B6-E 1-1609185-3 PE00XSSX0 5-1609930-9 6EGG1C-2 2-1609115-6 6VM1 0-1609128-1 CDSUW1030B6-C 2-1609186-2 PE0S0D000 9-1609955-2 6EGG8-1 2-1609115-8 6VM1C 0-1609128-2 CDSUW2010A6C 1-1609186-2 PE0S0DBX0 8-1609955-8 6EGG8-2 2-1609115-9 6VM1S 0-1609128-3 CDSUW2030B6-C 2-1609186-9 PE0S0DH30 4-1609929-7 6EGG8C-2 3-1609115-1 6VM1SC 0-1609128-4 CDSUX2030B6C 2-1609187-5 PE0S0DH3A 4-1609929-5 6EGS1-1 0-1609117-5 6VM2 0-1609128-5 F-2810 7-1609082-0 PE0S0DH3B 0-1609103-5 6EGS1-2 0-1609117-6 6VM2S 0-1609128-7 F-3297 0-1609096-1 PE0S0DH60 5-1609929-0 6EH1 0-1609012-3 6VM2SE 0-1609128-6 F-3297A 3-1609083-4 PE0S0DH6B 0-1609103-8 6EH3 0-1609012-4 6VM4 0-1609128-8 F-3380A 4-1609083-6 PE0S0DHXA 4-1609929-1 6EH4 0-1609013-1 6VM4C 0-1609128-9 F-3380B 4-1609083-7 PE0S0DL6C 0-1609109-2 6EH5 0-1609013-4 6VM4S 1-1609128-2 F-3380C 0-1609971-1 PE0S0DLXC 0-1609109-4 94 All specifications subject to change. Consult Tyco Electronics for latest design specifications. Corcom PN Tyco PN Corcom PN Tyco PN Corcom PN Tyco PN Corcom PN Tyco PN PE0S0DS30 1-1609104-6 PS000SS3B 6-1609107-3 PS0SSDSX0 5-1609107-2 RJ11-2X 0-1609214-1 PE0S0DS3A 2-1609104-3 PS000SS6A 4-1609107-3 PS0SSDSXA 1-1609951-6 RJ11-4L1B 2-1609208-2 PE0S0DS3B 3-1609104-0 PS000SS6B 5-1609107-5 PS0SSDSXB 1-1609951-7 RJ11-4L1S 2-1609208-1 PE0S0DS6A 5-1609929-4 PS000SSXA 4-1609107-9 PS0SSS000 0-1609101-9 RJ11-4L2B 2-1609208-7 PS000SSXB 6-1609107-1 PS0SSSH30 1-1609106-2 PE0S0DS6B 2-1609104-4 RJ11-4L2S 2-1609208-5 PS00SD000 0-1609101-4 PS0SSSH3A 1-1609106-4 PE0S0DSX0 5-1609929-2 RJ11-4LB 1-1609208-7 PS00SDH3A 7-1609951-3 PS0SSSH60 0-1609106-7 PE0S0DSXA 2-1609104-5 RJ11-4LC1B 0-1609209-8 PE0S0DSXB 2-1609104-9 PS00SDH3B 1-1609103-7 PS0SSSH6A 1-1609106-5 RJ11-4LC1S 0-1609209-6 PE0S0DZ6C 0-1609108-2 PS00SDH60 0-1609106-1 PS0SSSHXA 2-1609106-1 RJ11-4LC2B 1-1609209-3 PE0S0DZXC 0-1609108-5 PS00SDHXB 4-1609106-2 PS0SSSS3A 3-1609107-0 RJ11-4LC2S 1-1609209-0 PE0S0SH3A 6-1609929-0 PS00SDS6B 8-1609951-8 PS0SSSS3B 3-1609951-3 RJ11-4LS 1-1609208-5 PE0S0SL6C 0-1609109-3 PS00SS000 0-1609101-3 PS0SSSS6A 3-1609107-1 RJ11-4X 0-1609214-3 PE0S0SLXC 0-1609109-5 PS00SSH30 1-1609106-0 PS0SSSSXA 4-1609107-4 RJ11-6L1B 4-1609208-0 PE0S0SS6A 7-1609929-3 PS00SSS30 2-1609107-3 PS0SXD000 1-1609101-2 RJ11-6L1S 3-1609208-8 PS00SSS6A 4-1609107-1 PS0SXDH30 0-1609106-2 PE0S0SS6B 1-1609104-7 RJ11-6L2B 4-1609208-5 PS00XD000 0-1609101-6 PS0SXDH3A 2-1609106-7 PE0S0SSXA 6-1609929-7 RJ11-6L2S 4-1609208-3 PS00XDH30 4-1609106-3 PS0SXDH3B 3-1609951-8 PE0S0SSXB 2-1609104-2 RJ11-6LB 3-1609208-1 PE0S0SZ6C 0-1609108-4 PS00XDHX0 3-1609106-4 PS0SXDH60 2-1609106-6 RJ11-6LC1B 1-1609209-8 PE0S0SZXC 0-1609108-6 PS00XDHXA 4-1609106-4 PS0SXDH6A 2-1609106-8 RJ11-6LC1S 1-1609209-6 PE0SSDH3B 6-1609928-7 PS00XDS3B 7-1609107-4 PS0SXDHX0 4-1609106-6 RJ11-6LC2B 2-1609209-1 PE0SSDS3A 7-1609928-7 PS00XDS60 1-1609107-2 PS0SXDHXA 3-1609106-9 RJ11-6LC2S 2-1609209-0 PE0SSDS6A 8-1609928-1 PS00XDS6A 2-1609107-9 PS0SXDHXB 3-1609951-6 RJ11-6LS 2-1609208-9 PE0SSDS6B 8-1609928-2 PS00XDSXB 1-1609952-3 PS0SXDS30 0-1609107-6 RJ11-6N3B 0-1609212-6 PE0SSDSXB 7-1609928-4 PS00XS000 0-1609101-5 PS0SXDS3A 5-1609107-4 RJ11-6N3S 0-1609212-7 PS00XSBX0 0-1609105-5 PS0SXDS3B 6-1609107-6 PE0SSS000 0-1609100-1 RJ11-6N4B 0-1609212-8 PS00XSS30 9-1609107-1 PS0SXDS60 0-1609107-2 PE0SSSS30 0-1609929-0 RJ11-6N4S 0-1609212-9 PS00XSS60 1-1609107-1 PS0SXDS6A 6-1609107-7 PE0SSSS60 0-1609104-5 RJ11-6NB 0-1609212-4 PE0SSSS6A 0-1609929-1 PS00XSS6A 4-1609107-2 PS0SXDS6B 6-1609107-8 RJ11-6NS 0-1609212-5 PE0SSSSX0 0-1609104-7 PS00XSS6B 5-1609107-6 PS0SXDSX0 4-1609951-3 RJ11-6X 0-1609214-5 PE0SXD000 7-1609955-6 PS00XSSXA 4-1609107-8 PS0SXDSXA 5-1609107-3 RJ45-6L1B 5-1609208-0 PE0SXDBX0 7-1609955-2 PS0S0D000 0-1609101-8 PS0SXDSXB 8-1609107-9 RJ45-6L1S 4-1609208-9 PE0SXDH3A 1-1609103-3 PS0S0DBX0 0-1609105-9 PS0SXS000 1-1609101-1 RJ45-6L2B 5-1609208-2 PE0SXDH3B 0-1609929-8 PS0S0DBXB 1-1609105-1 PS0SXSBX0 0-1609105-2 RJ45-6L2S 5-1609208-1 PE0SXDH6B 1-1609103-0 PS0S0DH30 4-1609106-7 PS0SXSH30 1-1609106-3 RJ45-6LB 4-1609208-8 PS0S0DH3A 5-1609951-6 PS0SXSH3A 1-1609106-6 PE0SXDS30 2-1609929-0 RJ45-6LC1B 2-1609209-7 PS0S0DH3B 3-1609106-2 PS0SXSH3B 4-1609106-0 PE0SXDS3A 1-1609104-9 RJ45-6LC1S 2-1609209-6 PS0S0DH6A 3-1609106-3 PS0SXSH6A 1-1609106-7 PE0SXDS3B 1-1609929-8 RJ45-6LC2B 2-1609209-9 PE0SXDS6A 1-1609104-4 PS0S0DH6B 4-1609106-8 PS0SXSHXA 2-1609106-2 RJ45-6LC2S 2-1609209-8 PE0SXDS6B 2-1609104-0 PS0S0DHX0 3-1609106-1 PS0SXSS30 2-1609107-6 RJ45-6LS 4-1609208-7 PE0SXDSXA 1-1609929-4 PS0S0DHXA 4-1609106-9 PS0SXSS3A 3-1609107-2 RJ45-6X 1-1609214-0 PE0SXDSXB 1-1609929-5 PS0S0DHXB 3-1609106-0 PS0SXSS3B 6-1609107-9 RJ45-8L1B 5-1609208-7 PE0SXSS3A 1-1609104-2 PS0S0DS30 7-1609107-1 PS0SXSS60 2-1609107-0 RJ45-8L1S 5-1609208-5 PE0SXSS3B 3-1609929-4 PS0S0DS3A 7-1609107-0 PS0SXSS6A 3-1609107-3 RJ45-8L2B 6-1609208-0 PE0SXSS6A 3-1609929-7 PS0S0DS3B 8-1609107-0 PS0SXSS6B 5-1609107-9 RJ45-8L2S 5-1609208-9 PS0S0DS60 1-1609107-8 PS0SXSSXA 4-1609107-5 PM00SDHXB 1-1609941-4 RJ45-8LB 5-1609208-4 PS0S0DS6A 6-1609107-5 PSCS0DH3A 5-1609943-7 PM0S0DBXB 6-1609959-4 PS0S0DS6B 7-1609107-2 PSCS0DS30 7-1609943-2 RJ45-8LC1B 3-1609209-3 PM0S0DH60 0-1609103-6 PM0S0DH6A 7-1609940-5 PS0S0DSX0 5-1609107-1 PSCS0SS3A 8-1609107-4 RJ45-8LC1S 3-1609209-0 PM0S0DS30 8-1609940-5 PS0S0DSXA 7-1609107-7 PSCS0SS6A 5-1609107-0 RJ45-8LC2B 4-1609209-1 PM0S0DS3A 8-1609940-2 PS0S0DSXB 8-1609107-1 PSJ00D000 1-1609101-7 RJ45-8LC2S 3-1609209-6 PM0S0DS60 3-1609104-1 PS0S0S000 0-1609101-7 PSJ00S000 1-1609101-8 RJ45-8LCT1-B 1-1609211-1 PM0SSDH30 7-1609939-8 PS0S0SH3A 6-1609951-4 PSJ0SD000 2-1609101-0 RJ45-8LCT1-S 1-1609211-0 PM0SSDH60 8-1609939-2 PS0S0SHXA 1-1609106-9 PSJ0SS000 1-1609101-9 RJ45-8LCT2-B 1-1609211-3 PM0SXDBX0 0-1609102-2 PS0S0SS30 2-1609107-4 PSJ0XD000 1-1609101-6 RJ45-8LS 5-1609208-3 PS0S0SS3A 7-1609107-3 PSJ0XS000 1-1609101-3 PM0SXDS3B 3-1609940-6 RJ45-8N3B 1-1609212-3 PS0S0SS3B 6-1609107-4 PSJ0XSH6A 6-1609947-4 PS000D000 0-1609101-2 RJ45-8N3S 1-1609212-4 PS0S0SS60 1-1609107-7 PSJS0D000 2-1609101-1 PS000DD3D 0-1609111-3 RJ45-8N4B 1-1609212-5 PS000DD6D 0-1609111-5 PS0S0SS6A 4-1609107-0 PSJS0DH3A 4-1609946-3 RJ45-8N4S 1-1609212-6 PS000DDXD 0-1609111-7 PS0S0SS6B 5-1609107-8 PSJS0DH6A 4-1609946-6 RJ45-8NB 1-1609212-0 PS000DH30 4-1609952-1 PS0S0SSX0 3-1609107-6 PSJS0DS60 6-1609946-1 RJ45-8NS 1-1609212-2 PS000DH3A 3-1609106-7 PS0S0SSXA 4-1609107-6 PSJS0S000 1-1609101-5 RJ45-8X 1-1609214-1 PS000DH6B 4-1609952-3 PS0S0SSXB 6-1609107-2 PSJS0SS3A 8-1609107-6 RJ45-8Z4 0-1609215-6 PS000DHXA 2-1609106-0 PS0SPDS6B 7-1609107-8 PSJS0SS60 8-1609107-7 RJH-4LB 6-1609208-1 PS000DHXB 3-1609952-7 PS0SSD000 1-1609101-0 PSJSSD000 2-1609101-3 SLA214-100 1-1609192-4 PS0SSDH30 1-1609951-1 PSJSSDS60 6-1609945-6 PS000DS30 9-1609107-0 SLA214-25 1-1609192-9 PS0SSDH3A 0-1609951-8 PSJSSS000 2-1609101-2 PS000DS3A 4-1609952-9 SLA214-4-4 3-1609192-1 PS0SSDH60 1-1609951-5 PSJSXD000 1-1609101-4 PS000DS3B 5-1609952-0 SLA253-4-4 0-1609193-7 PS000DS60 0-1609107-8 PS0SSDH6A 1-1609951-2 PSJSXDH3A 9-1609945-5 SLA254-4-4 1-1609193-3 PS000DS6B 7-1609107-6 PS0SSDH6B 1-1609951-3 PSJSXDS6A 1-1609946-1 SLA255-4-4 1-1609193-8 PS000DSXA 4-1609952-6 PS0SSDHXA 0-1609951-4 PSLS0SS6A 6-1609949-2 SLA257-4-4 2-1609194-6 PS000DSXB 7-1609107-9 PS0SSDS30 0-1609107-5 RJ11-2LB 0-1609208-3 TS260S-00 0-1609078-5 PS000S000 0-1609101-1 PS0SSDS3A 1-1609951-9 RJ11-2LC1B 0-1609209-2 TS260W-00 0-1609078-3 PS000SD3D 0-1609111-4 PS0SSDS3B 2-1609951-0 RJ11-2LC1S 0-1609209-1 WFV3470 4-1609192-4 PS000SD6D 0-1609111-6 PS0SSDS60 0-1609107-1 RJ11-2LC2B 0-1609209-4 WFV3544 4-1609192-5 PS0SSDS6A 2-1609951-2 RJ11-2LC2S 0-1609209-3 PS000SDXD 0-1609111-8 WFV3563 2-1609193-7 PS0SSDS6B 2-1609951-3 RJ11-2LS 0-1609208-1 PS000SS30 2-1609107-2 All specifications subject to change. Consult Tyco Electronics for latest design specifications. 95 CORCOM – Your Partner for RFI Solutions Manufacturing Program High Current Filter ● High current filter to 4 x 4.000 A for buildings and cabins, manufactured according to UL and MIL Standard, choice of inductive or capacitive inputs. ● Signal-, data- and control line filters, single filters and cabinet style with 4 to 200 filter pairs. For detailed information call for the separate catalogue. 96 All specifications subject to change. Consult Tyco Electronics for latest design specifications. 1308230 - CORCOM, Englisch 07.08.2003 12:56 Uhr Seite 3 CORCOM Catalog 1308230 Rev. 07-03 RFI Power Line Filters Filter Selection Chart Noise into Noise out of equipment equipment Filter Purpose Interference Suppression No 3–Phase Yes Yes 3–Phase No Current Current ? ? No Yes For Medical Application No Yes For Yes For No ? medical Medical Application Application ? ? Please try: not included in Filter Selection Chart: Please try: Please try: EH-Series P. 40 AYO-Series P. 76 EH-Series P. 40 Accessory Outlet Filters P. 30 No Yes for High Yes No BCD-Series P. 85 2-Phase-Filters P. 66 EAH-Series P. 31 EAH-Series P. 31 Tempest- Distortion Level EBH-Series P. 31 F-Series P. 77 EBH-Series P. 31 Requirements ? A-Series P. 68 CH-Series P. 26 P-Series P. 9 ? AYA-Series P. 74 P-Series P. 9 EHG-Series P. 28 Please try: EHT-Series P. 58 FCD-Series P. 80 EHL-Series P. 19 Please try: Tempest P. 88 FCD10BS-Series P. 83 Switching EHL-Series P. 19 EHM-Series P. 13 Yes No VS-Series P. 54 Small EHM-Series P. 13 AYC-Series P. 70 F-3374 P. 13 Power Supply No Yes (standard requir.) ADT-Series P. 72 Applicattion Mounting F-3374 P. 13 EHT-Series P. 58 VV-Series P. 54 ? Size with EHQ-Series P. 62 EHQ-Series P. 62 Please try: VW-Series P. 54 IEC 320 MV-Series P. 54 MV-Series P. 54 P. 77 (Increased requir.) F-3380 Connector 3EHZ1 P. 40 3EHZ1-SeriesP. 61 T-Series P. 58 ? Yes Following No (Very high requir.) VDE FC-Series P. 64 Regulations ? Please try: Please try: EOP-Series P. 44 EF-Series P. 34 Small Class A Class B Which Class A Class B Yes No EBP-Series P. 44 EEA-Series P. 31 Which Mounting Size VDE-Limit FCC-Class EDP-Series P. 44 EEB-Series P. 31 with IEC320 ? XP-Series P. 42 ED-Series P. 36 ? Connector F-3443 P. 43 EC-Series P. 38 ? B-Series P. 46 EGG-Series P. 28 Please try: Please try: Please try: Please try: K-Series P. 48 C-Series P. 26 EOP-Series P. 44 EBP-Series P. 44 EF-Series P. 34 EOP-Series P. 44 DK-Series P. 52 6J4 P. 25 Yes Switching No Yes Switching No EBP-Series P. 44 EDP-Series P. 44 EEA-Series P. 31 F-3443 P. 43 R-Series P. 50 M-Series P. 13 Frequency Frequency EDP-Series P. 44 XP-Series P. 42 EEB-Series P. 31 EBP-Series P. 44 >50kHz? EDL-Series P. 19 >50kHz VW-Series P. 54 3EX1-Series P. 61 ED-Series P. 36 EDP-Series P. 44 P-Series P. 9 ? SK-Series P. 56 YP-Series F-3550 P. 36 XP-Series P. 42 P. 42 LA-Series P. 23 T-Series P. 58 DK-Series P. 52 EC-Series P. 38 B-Series P. 46 F-3558 P. 22 Please try: Please try: Please try: Please try: SK-Series P. 56 EGG-Series P. 28 K-Series P. 48 EBP-Series P. 44 EBP-Series P. 44 G/N-Series P. 45 ZP-Series P. 42 3EZ1-Series P. 61 C-Series P. 26 DK-Series P. 52 EDP-Series P. 44 EDP-Series P. 44 F-3426 P. 62 M-Series P. 13 EP-Series P. 60 6J4-Series P. 25 R-Series P. 50 EP-Series P. 60 YP-Series P. 42 LA-Series P. 23 P-Series P. 9 (very high requir.) SK-Series P. 56 F-7332A P. 23 F-3558 P. 22 G/N-Series S. 45 T-Series P. 58 T-Series P. 58 M-Series P. 13 (standard requir.) FC-B-Series P. 64 Q-Series P. 62 EDL-Series P. 19 FC-Series P. 64 LA-Series P. 23 Yes No Problem Please contact your local Tyco Electronics Please Order solved Sales Office (see back page) ? 1308230 - CORCOM, Englisch 07.08.2003 12:56 Uhr Seite 4 Global Contacts Americas Argentina – Buenos Aires Chile – Santiago United States – Venezuela – Caracas Phone: +54-1-733-2000 Phone: +56-2-739-1230 Harrisburg, PA Phone: +58-2-986-7774 Fax: +54-1-717-0988 Fax: +56-2-739-1227 Phone: +1-717-564-0100 Fax: +58-2-986-9739 Fax: +1-717-986-7575 Brasil – São Paulo Colombia – Bogota For Latin/South American Phone: +55-11-3611-1311 Phone: +57-1-231-9398 Troy, MI Countries not shown Fax: +55-11-3611-0397 Fax: +57-1-240-3769 Phone: +1-248-273-3359 Phone: +54-11-4733-2015 Fax: +1-248-273-3322 Fax: +54-11-4733-2083 Canada – Toronto Mexico – Mexico City Phone: +905-475-6222 Phone: +52-5-729-0400 Customer Service: Fax: +905-474-5520 Fax: +52-5-361-8545 Phone: +1-800-522-6752 Asia/Pacific Australia – Sydney Korea – Seoul People’s Republic of China – Singapore – Singapore Phone: +61-2-9554-2600 Phone: +82-2-3415-4500 Hong Kong Phone: +65-480-4525 Fax: +61-2-9502-2556 Fax: +82-2-3486-3810 Phone: +852-2735-1628 Fax: +65-482-1012 Fax: +852-2735-0243 India – Bangalore Malaysia – Selangor Taiwan – Taipei Phone: +91-80-841-0200 Phone: +60-3-7805-3055 Shanghai Phone: +886-2-2664-9977 Fax: +91-80-841-0210 Fax: +60-3-7805-3066 Phone: +86-21-5383-8188 Fax: +886-2-2664-9900 Fax: +86-21-5383-8018 Indonesia – Jakarta New Zealand – Auckland Thailand – Bangkok Phone: +62-21-526-7852 Phone: +64-9-634-4580 Shunde Phone: +66-2-955-0500 Fax: +62-21-526-7856 Fax: +64-9-634-4586 Phone: +86-765-775-1368 Fax: +66-2-955-0505 Fax: +86-765-775-2823 Japan – Kawasaki, Kanagawa Philippines – Makati City Vietnam – Ho Chi Minh City Phone: +81-44-844-8111 Phone: +632-867-8641 Phone: +84-8-930-4547 Fax: +81-44-812-3207 Fax: +632-867-8661 Fax: +84-8-930-3443 Europe/Middle East/Africa Austria – Vienna Tyco Electronics Export – Lithuania – Vilnius South Africa – Port Elizabeth Phone: +43-1-90-560-0 Cergy-Pontoise Cedex Phone: +370-5-2131-402 Phone: +27-41-405-4500 Fax: +43-1-90-560-1333 Phone: +33-1-3420-8866 Fax: +370-5-2131-403 Fax: +27-41-486-1314 office.vienna@tycoelectronics.com Fax: +33-1-3420-8300 RMasteika@tycoelectronics.com jblomerus@tycoelectronics.com Belgium – Kessel-Lo Germany – Bensheim Netherlands – ’s-Hertogenbosch Spain – Barcelona Phone: +32-16-352-300 Phone: +49-6251-133-0 Phone: +31-73-6246-246 Phone: +34-93-291-0330 Fax: +32-16-352-352 Fax: +49-6251-133-1600 Fax: +31-73-6212-365 Fax: +34-93-201-7879 beneluxsales@tycoelectronics.com tyco-sales@tycoelectronics.com beneluxsales@tycoelectronics.com Sweden – Upplands Väsby Product Information Center: Product Information Center: Bulgaria – Sofia Phone: +46-8-50-72-50-00 Phone: +49-6251-133-1999 Phone: +31-73-6246-999 Phone: +359-2-971-2152 Fax: +46-8-50-72-50-01 Fax: +49-6251-133-1988 Fax: +31-73-6246-998 Fax: +359-2-971-2153 info.se@tycoelectronics.com ampbg@internet-bg-net Great Britain – Stanmore Middlesex Norway – Nesbru Switzerland – Steinach Phone: +44-208-954-2356 Phone: +47-66-77-88-99 Czech Republic – Kurim Phone: +41-71-447-0447 Fax: +44-208-954-6234 Fax: +47-66-77-88-55 Phone: +420-5-41-162-111 Fax: +41-71-447-0444 busdevelop@tycoelectronics.com info.no@tycoelectronics.com Fax: +420-5-41-162-223 info.ch@tycoelectronics.com Product Information Center: amp@tycoelectronics.cz Poland – Warsaw Freephone GB: 0800-267-666 Turkey – Istanbul Denmark – Viby J Phone: +48-22-45-76-700 Phone: +44-141-810-8967…69 Phone: +90-212-281-8181…3 Phone: +45-70-15-52-00 Fax: +48-22-45-76-720 Fax: +44-141-810-8971 +90-212-282-5130/5430 Fax: +45-86-29-51-33 poland.info@tycoelectronics.com Fax: +90-212-281-8184 info.dk@tycoelectronics.com Greece – Athens Romania – Bucharest ProductInfo.Turkey@tycoelectronics.com Phone: +30-10-9370-396/397 Egypt – Cairo Phone: +40-21-311-3479 + 3596 Fax: +30-10-9370-655 Phone: +20-2-417-76-47 Ukraine – Kiev Fax: +40-21-312-0574 gbakatsas@tycoelectronics.com Fax: +20-2-419-23-34 Phone: +38-044-238-6908 rpupezaamp@pcnet.ro mgamil@tycoelectronics.com Fax: +38-044-568-5740 Hungary – Budapest Russia – Moscow SMarchuk@tycoelectronics.com Estonia – Tallinn Phone: +36-1-289-1000 Phone: +7-095-926-55-06/07/08/09 Phone: +372-65-05-474 Fax: +36-1-289-1010 Fax: +7-095-926-55-05 Fax: +372-65-05-470 office.budapest@tycoelectronics.com OBorrisowa@tycoelectronics.com info.ee@tycoelectronics.com Ireland – Dublin Russia – St. Petersburg Finland – Helsinki Phone: +353-1-820-3000 Phone: +7-812-118-8192 Phone: +358-95-12-34-20 Fax: +353-1-820-9790 Fax: +7-812-118-8193 Fax: +358-95-12-34-250 john.padley@tycoelectronics.com ABlokhin@tycoelectronics.com info.fi@tycoelectronics.com Israel – Yokneam France – Cergy-Pontoise Cedex Slovenia – Ljubljana Phone: +972-4-959-0508 Phone: +33-1-3420-8888 Phone: +386-1561-3270 Fax: +972-4-959-0506 Fax: +33-1-3420-8600 Fax: +386-1561-3240 Product Information Center: Italy – Collegno (Torino) barbara.dominic@tycoelectronics.com Phone: +33-1-3420-8943 Phone: +39-011-4012-111 Fax: +33-1-3420-8623 Fax: +39-011-4031116 Tyco Electronics AMP GmbH certified according ISO 9001, QS 9000/VDA 6.1 and ISO 14001 © 2003 Tyco Electronics AMP GmbH • AMPèrestr. 12–14, 64625 Bensheim • Phone +49-6251-133-0, Fax +496251-133-1600 1308230–5M–ST–07-03 Printed in Germany www.tycoelectronics.com
Frequently asked questions
What makes Elite.Parts unique?

What kind of warranty will the F-3374 have?

Which carriers does Elite.Parts work with?

Will Elite.Parts sell to me even though I live outside the USA?

I have a preferred payment method. Will Elite.Parts accept it?

What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods