CORCOM 5EHM1

Description
MODULE POWER ENTRY 5A MEDICAL 1V
Part Number
5EHM1
Price
Request Quote
Manufacturer
CORCOM
Lead Time
Request Quote
Category
PRODUCTS - 5
Datasheet
Extracted Text
Power Entry Modules CORCOM Product Guide Power Entry Module with Optional RFI Power Line Filters for General and Medical Applications M Series XM/ZM UL Recognized CSA Certified VDE Approved VM FM Models – General purpose RFI filter designed for sus- M Series ceptibility applications, effectively providing RFI control of The M series power entry modules offer the most choices line-to-ground noise. The design is compact and meets of power entry components and filtering options to fit a the very low leakage current requirements of VDE portable specific need. The fully configured M series expands the equipment as well as (120 Volt) UL544 non-patient medical options of a manufacturer whose products are marketed equipment. worldwide. One component, fully assembled and tested, XM Models – High performance RFI filter designed to bring provides the capability of interfacing a multi-voltage power most digital equipment (including switching power supply to any common voltage or fusing scheme in the supplies) into compliance with FCC Part 15J, Class B world, without modification. conducted emissions limits. •The IEC connector provides an internationally accepted ZM Models – Premium RFI filter designed to bring most power entry termination, which can be used with a variety digital equipment (including switching power supplies) into of line cords. compliance with EN55022, Level B (as well as FCC Part •The selectable fuseholder allows use of single or dual 15J, Class B) conducted emissions limits. European fuses, or a single North American fuse. •The optional DPST on/off switch breaks both sides of the line and is labeled with the international I/O markings. Fuse Installation Instructions •The optional voltage selector provides a convenient means to change transformer primary connection, and it is available in both 2-voltage and 4-voltage configurations. •The series is available with four filter circuits to meet a variety of applications, and convenient connections are provided on unfiltered models to allow wiring of a separate RFI filter. The M series is a family of components offering greater flexibility and cost-effectiveness in the selection of primary power components. Wiring to the modules is accom- plished via .110” terminals for labor savings and convenience. Four filter circuits provide a choice of attenuation tailored to specific categories of susceptibility and emissions needs. 1. Remove power cord. 2. Pry door open at socket. HM Models – This medical filter provides susceptibility 3. Lift and swing door into socket. protection without the leakage current associated with 4. Lift fuse holder out of housing. line-to-ground capacitors. Designed to allow equipment 5. Install one (1) AG fuse or two (2) metric fuses*. to meet UL544 for patient care and non-patient care 6. Replace fuse holder into housing. equipment, the HM filter has a maximum leakage current 7. Swing and snap door back in place. of 2 µA at 120 VAC 60 Hz. See Appendix C for more information on medical applications and UL standards. *Install fuses on one side only, do not install both AG and metric fuses at the same time. 115 Catalog 1654001 Dimensions are in inches and Dimensions are shown for USA Cust. Svc.: 1-800-468-2023 www.cor.com Revised 03-04 millimeters unless otherwise reference purposes only. CORCOM Prods: 1-847-680-7400 www.tycoelectronics.com specified. Values in italics Specifications subject 1-508-992-4495 are metric equivalents. to change. Germany: 49-89-6089-0 CORCOM Product Guide Power Entry Module with Optional RFI Power Line Filters for General and Medical Applications (Continued) M Series UNFILTERED MODELS Current Rating Current Rating Available Voltage DPST Part Mounting Fuseholder @120VAC 250VAC Selection On/Off Number Style Type (Amps) (Amps) Position* Switch 6VM1 6 6 1 - Flange Selectable 6VM1C 6 6 1 - Snap-in Selectable 6VM1S 6 4 1 • • Flange Selectable 6VM1SC 6 4 1 • • Snap-in Selectable 6VM2 6 6 2 - Flange Selectable 6VM2S 6 6 2 • • Flange Selectable 6VM4 6 6 4 - Flange Selectable 6VM4C 6 6 4 - Snap-in Selectable 6VM4S 6 4 4 • • Flange Selectable 6VM4SC 6 4 4 • • Snap-in Selectable * 1 - 120V/240V Fixed 2 - 120/240 V Selectable 4 - 100V, 120V, 230V, 240V Selectable • • Includes DPST switch FILTERED MODELS RFI Current Rating Current Rating Available Voltage DPST Part Mounting Fuseholder Filter @120VAC @250VAC Selection On/Off Number Style Type Type✝(Amps) (Amps) Position Switch 1 5EHM1 Medical 54 1 − − Flange Selectable 1 5EHM1S Medical 54 1 • • Flange Selectable 1 5EHM4 Medical 54 4 − − Flange Selectable 1 5EHM4S Medical 54 4 • • Flange Selectable 2 5EFM1 General Purpose54 1 − − Flange Selectable 2 5EFM1C General Purpose54 1 − − Snap-in Selectable 2 5EFM1S General Purpose54 1 • • Flange Selectable 2 5EFM1SC General Purpose54 1 • • Snap-in Selectable 2 5EFM4 General Purpose54 4 – Flange Selectable 2 5EFM4C General Purpose54 4 – Snap-in Selectable 2 5EFM4S General Purpose54 4 • • Flange Selectable 2 5EFM4SC General Purpose54 4 • • Snap-in Selectable 3 3EXM1S SMPS FCC-B32 1 • • Flange Selectable 3 3EXM4 SMPS FCC-B32 4 − − Flange Selectable 3 3EXM4S SMPS FCC-B32 4 • • Flange Selectable 4 3EZM1S SMPS EN55022-B32 1 • • Flange Selectable 4 3EZM4 SMPS EN55022-B32 4 – Flange Selectable 4 3EZM4S SMPS EN55022-B32 4 • • Flange Selectable • • Includes DPST switch 1 Medical filter for very low leakage UL 544 health care applications. 2 General purpose filter for susceptibility applications. 3 Emissions filter for switching power supply applications where FCC-B level requirements must be met. 4 Emissions filter for switching power supply applications where EN55022-B level requirements must be met. Refer to page 97 for more information on available RFI filter types. * 1 - 120V/240V Fixed 4 - 100V, 120V, 230V, 240V Selectable Fuse Changing European Fusing Arrangement** North American Fusing Arrangement** **Install fuses on one side only. Do Not install both AG and Metric fuses at the same time. 116 Catalog 1654001 Dimensions are in inches and Dimensions are shown for USA Cust. Svc.: 1-800-468-2023 www.cor.com Revised 03-04 millimeters unless otherwise reference purposes only. CORCOM Prods: 1-847-680-7400 www.tycoelectronics.com specified. Values in italics Specifications subject 1-508-992-4495 are metric equivalents. to change. Germany: 49-89-6089-0 Power Entry Modules CORCOM Product Guide Power Entry Module with Optional RFI Power Line Filters for General and Medical Applications (Continued) M Series Specifications – Unfiltered Models Specifications – Filtered Models Maximum leakage current,each line-to-ground HM FM XM/ZM Hipot rating (one minute): @ 120 VAC 60 Hz: 2μA .25 mA .30 mA line-to-ground 1500 VAC @ 250 VAC 50 Hz: 5μA .50 mA .50 mA line-to-line 1450 VDC Hipot rating (one minute): line-to-load (switch off) 2500 VAC line-to-ground: HM Models 1500 VAC Operating voltages: 100, 120, 230, 240 VAC FM/XM/ZM 1500 VAC Operating frequency: 50/60 Hz line-to-line All Models 1450 VDC Switch: Double-insulated, rated for 100,000 operations at full load. Operating voltages: 100, 120, 230, 240 VAC 10,000 operations at 70 Amps inrush current. Operating frequency: 50/60 Hz Fuse (not included): Reversible fuseholder, accepts Rated voltage (max.): 250 VAC one 1/4" x 1-1/4" fuse or two 5 x 20 mm fuses. Switch: Double-insulated, rated for 100,000 operations at full load. Terminals: .110 [2.79] terminals 10,000 operations at 70 Amps inrush current. Fuse (not included): Reversible fuseholder, accepts Electrical Schematics – Unfiltered Models one 1/4" x 1-1/4" fuse VM (1-Voltage) or two 5 x 20 mm fuses Power On/Off Terminals: .110 [2.79] terminals Note 3 K K Neutral Minimum insertion loss in dB: Note 2 Line-to-ground in 50 ohm circuit Current Frequency-MHz 120V L Rating .01 .05 .15 .5 1 5 10 30 Hot L G Customer HM Transformer Primaries 5A - - 14 18 19 22 22 17 VM (2-Voltage) FM 05A - - 14 21 26 40 45 40 120V 240V Power On/Off A XM Note 3 A 120V HB B K 120V 3A 2 13 23 40 46 44 44 44 Neutral Note 2 Note 1 ZM C C 3A 15 29 39 46 43 40 40 40 D D 120V E E 120V Hot J F Line-to-line in 50 ohm circuit L F F Note 1 Note 4 G Customer Transformer Primaries Current Frequency-MHz Rating .02 .03 .05 .07 .15 .5 1 5 10 30 VM (4-Voltage) XM 120V 230V 03A - - - 5 34 62 68 60 50 40 100V 240V Power On/Off 20V ZM Note 3 A A 100V 3A 5 13283755 75 75 62 54 44 K HB Neutral Note 2 Note 1 230V Nomenclature relates to pending European CENELEC agreement. C C D D E E 120V L J F F Hot Note 1 G Customer Transformer Primaries Note 1: Jumpers required if no input filter is used. Note 2: Provision for dual European style fusing. Note 3: On/off switch present only with "S" suffix. Note 4: When using a center-tapped transformer, the C-F winding should be the low voltage (high current) winding and must be capable of handling the full primary current in the 120V position. 117 Catalog 1654001 Dimensions are in inches and Dimensions are shown for USA Cust. Svc.: 1-800-468-2023 www.cor.com Revised 03-04 millimeters unless otherwise reference purposes only. CORCOM Prods: 1-847-680-7400 www.tycoelectronics.com specified. Values in italics Specifications subject 1-508-992-4495 are metric equivalents. to change. Germany: 49-89-6089-0 1 2 3 1 2 2 4 CORCOM Product Guide Power Entry Module with Optional RFI Power Line Filters for General and Medical Applications (Continued) M Series Case Dimensions – Unfiltered Models Case Dimensions – Filtered Models AB C D E F G AB C D E F Part No. (max) ±0.01 (max) (max) (max) Part No. (max) ±0.01 (max) (max) (max) ±0.25 ±0.25 5EFM1 3.39 2.84 1.14 2.44 2.19 2.5 3.39 2.84 1.14 2.44 1.45 2.5 — 6VM1 5EHM1 86.1 72.1 29.0 62.0 55.6 63.5 86.1 72.1 29.0 62.0 36.8 63.5 2.56 1.14 2.44 2.19 2.49 2.56 1.14 2.44 1.45 2.5 5EFM1C — — 6VM1C — 65.0 29.0 62.0 55.6 63.2 86.1 29.0 62.0 36.8 63.2 5EFM1S 4.17 3.62 1.14 3.22 2.19 3.28 4.17 3.62 1.14 3.22 1.45 3.28 — 6VM1S 5EHM1S 105.9 91.9 29.0 81.8 55.6 83.3 105.9 91.9 29.0 81.8 36.8 83.3 3.34 1.14 3.27 2.19 3.27 3.34 1.14 3.27 1.45 3.27 5EFM1SC — — 6VM1SC — 84.8 29.0 83.1 55.6 83.1 84.8 29.0 83.1 36.8 83.1 5EFM4 3.88 3.32 1.14 2.92 2.19 2.98 6VM2 3.88 3.32 1.14 2.92 1.45 2.98 — 5EHM4 98.6 84.3 29.0 74.2 55.6 75.7 6VM4 98.6 84.3 29.0 74.2 36.8 75.7 3.04 1.14 2.92 2.19 2.97 3.04 1.14 2.92 1.45 2.97 5EFM4C — — 6VM4C — 98.6 29.0 74.2 36.8 75.4 77.2 29.0 74.2 55.6 75.4 5EFM4S 4.65 4.1 1.14 3.7 2.19 3.76 6VM2S 4.65 4.1 1.14 3.72 1.45 3.76 — 5EHM4S 118.1 104.1 29.0 94.0 55.6 95.5 6VM4S 118.1 104.1 29.0 94.5 36.8 95.5 3.82 1.14 3.7 1.45 3.75 3.82 1.14 3.7 2.19 3.75 5EFM4SC — — 6VM4SC — 97.0 29.0 94.0 55.6 95.3 97.0 29.0 94.0 36.8 95.3 3EXM1S 4.17 3.62 1.14 3.22 1.72 3.28 3.3 3EZM1S 105.9 91.9 29.0 81.8 43.7 83.8 83.8 3EXM4 3.88 3.32 1.14 2.92 1.72 2.98 2.99 3EZM4 98.6 84.3 29.0 74.2 43.7 75.7 75.9 Voltage Selection 3EXM4S 4.65 4.1 1.14 3.72 1.72 3.76 3.8 To change selected voltage: open cover, using small 3EZM4S 118.1 104.1 29.0 94.5 43.7 95.5 96.5 blade screwdriver or similar tool; set aside cover/fuse block assembly; pull voltage selector card straight out of housing, using indicator pin; orient selector card so that desired voltage is readable at the bottom; orient indicator Recommended Panel Cutout pin to point up when desired voltage is readable at bottom (note that when indicator pin is fixed, successive voltages *Blind insert are selected by rotating the card 90° clockwise); insert XM and ZM voltage selector card into housing, printed side of card Models only facing forward toward IEC connector and edge containing + 1.17 .020 *4S Models the desired voltage first; replace cover, and verify that + + 1.88 .020 29.7 .508 + 47.8 .508 indicator pin shows the desired voltage. + 1.13 .020 *1S & 4 models + 28.7 .508 0.13 R 3.30 .570 Voltage Selector Card Orientation 14.5 1.145 Holes (2) 29.08 .170 Dia. 4.32 .175 F 4.45 B 1 0 0 1 2 0 100V 120V Note: Snap-in models allow front mount only. XM and ZM models allow back mount only. FM and HM models allow front or back mounting. 0 0 Accessories for M series include interconnection assembly, medical standoff bracket, voltage selector cards, and insulating shroud. See page 131. 2 3 0 2 4 0 All mounting holes countersunk. 230V 240V 118 Catalog 1654001 Dimensions are in inches and Dimensions are shown for USA Cust. Svc.: 1-800-468-2023 www.cor.com Revised 03-04 millimeters unless otherwise reference purposes only. CORCOM Prods: 1-847-680-7400 www.tycoelectronics.com specified. Values in italics Specifications subject 1-508-992-4495 are metric equivalents. to change. Germany: 49-89-6089-0 0 0 0 2 4 1 2 0 0 0 0 0 1 0 3 2 0 1 2 4 2 3 Power Entry Modules CORCOM Product Guide Power Entry Module with Optional RFI Power Line Filters for General and Medical Applications (Continued) M Series Case Styles – Unfiltered Models 6VM1 (IEC Connector, Selectable Fuseholder) 6VM2 & 6VM4 (IEC Connector, Voltage Selector, Selectable Fuseholder) USE ONLY WITH 250V FUSES C 100V USE ONLY WITH 120V DISCONNECT POWER 250V FUSES 230V BEFORE REPLACING FUSES C 240V DISCONNECT POWER BEFORE REPLACING FUSES E D E D B B A A 6VM1C (IEC Connector, Selectable Fuseholder, Snap-in) 6VM4C (IEC Connector, Voltage Selector, Selectable Fuseholder, Snap-In) USE ONLY WITH 250V FUSES C 100V DISCONNECT POWER USE ONLY WITH 120V BEFORE REPLACING FUSES 250V FUSES 230V C DISCONNECT POWER 240V BEFORE REPLACING FUSES D E D A E A 6VM1S (IEC Connector, DPST On/Off Switch, Selectable 6VM2S & 6VM4S (IEC Connector, DPST On/Off Switch, Fuseholder) Voltage Selector, Selectable Fuseholder) 100V USE ONLY WITH USE ONLY WITH 120V 250V FUSES C 250V FUSES 230V C 240V DISCONNECT POWER DISCONNECT POWER BEFORE REPLACING FUSES BEFORE REPLACING FUSES E D E D B B A A 6VM1SC (IEC Connector, DPST On/Off Switch, 6VM4SC (IEC Connector, DPST On/Off Switch, Voltage Selectable Fuseholder, Snap-In) Selector, Selectable Fuseholder, Snap-In) 100V USE ONLY WITH USE ONLY WITH 120V 250V FUSES 250V FUSES C C 230V DISCONNECT POWER DISCONNECT POWER 240V BEFORE REPLACING FUSES BEFORE REPLACING FUSES B E D E A A Recommended Panel Cutout (Snap-In Only) 0.13 R 3.30 1.145 29.08 F Typical dimensions: Mounting Holes: .155 [3.94] Dia. (2) with .279 [7.09] Dia. x 82˚ Countersunk. All mounting holes countersunk. Panel Thickness: .06 - .09 [1.53 -2.29] 119 Catalog 1654001 Dimensions are in inches and Dimensions are shown for USA Cust. Svc.: 1-800-468-2023 www.cor.com Revised 03-04 millimeters unless otherwise reference purposes only. CORCOM Prods: 1-847-680-7400 www.tycoelectronics.com specified. Values in italics Specifications subject 1-508-992-4495 are metric equivalents. to change. Germany: 49-89-6089-0 CORCOM Product Guide Power Entry Module with Optional RFI Power Line Filters for General and Medical Applications (Continued) M Series XM & ZM (1-Voltage) Electrical Schematics - Filtered Models Power On/Off FM & HM (1-Voltage) Note 2 HB Neutral Note 1 Power On/Off Note 2 HB Neutral Note 1 Note 3 JF Phase G J F Phase XM & ZM (4-Voltage) G 120V 230V 100V 240V FM & HM (4-Voltage) 20V Power On/Off A A 120V 230V Note 4 Note 2 100V 240V H B 100V K Neutral Note 1 20V Power On/Off A A C C Note 2 H 100V Neutral K B Note 1 D D Note 4 C C E E Note 3 D D 120V Phase J F L F Note 4 G Customer E E Transformer Primaries 120V J F F L Phase Note 4 G Customer 5EFM1SC (IEC Connector, DPST On/Off Switch, Transformer Primaries Selectable Fuseholder) Case Styles - Filtered Snap-In Models USE ONLY WITH 250V FUSES DISCONNECT POWER 5EFM1C (IEC Connector, Selectable Fuseholder) BEFORE REPLACING FUSES USE ONLY WITH 250V FUSES A DISCONNECT POWER BEFORE REPLACING FUSES C D A C D E E 5EFM4SC (IEC Connector, DPST On/Off Switch, Voltage Selector, Selectable Fuseholder) 5EFM4C (IEC Connector, Voltage Selector, Selectable 100V USE ONLY WITH 120V 250V FUSES Fuseholder) 230V DISCONNECT POWER 240V BEFORE REPLACING FUSES 100V USE ONLY WITH 120V 250V FUSES A 230V DISCONNECT POWER 240V BEFORE REPLACING FUSES C D A D C E E Note 1: Provision for dual fusing (Euro standard) Note 2: Power on/off switch with suffix "S" only Note 3: HM models without line-to-ground capacitors Note 4: Models HM4, FM4, XM4, and ZM4 have added terminals K and L. External switch or jumper must be placed from K to H and L to J. 230V Nomenclature relates to pending European CENELEC agreement. 120 Catalog 1654001 Dimensions are in inches and Dimensions are shown for USA Cust. Svc.: 1-800-468-2023 www.cor.com Revised 03-04 millimeters unless otherwise reference purposes only. CORCOM Prods: 1-847-680-7400 www.tycoelectronics.com specified. Values in italics Specifications subject 1-508-992-4495 are metric equivalents. to change. Germany: 49-89-6089-0 Power Entry Modules CORCOM Product Guide Power Entry Module with Optional RFI Power Line Filters for General and Medical Applications (Continued) M Series Case Styles – Filtered Models Case Styles – Filtered Models 5EHM1 & 5EFM1 (IEC Connector, Selectable 3EXM4 & 3EZM4 (IEC Connector, Voltage Selector, Fuseholder) Selectable Fuseholder) G Thread 6-32 x 1/4 USE ONLY WITH 250V FUSES C DISCONNECT POWER BEFORE REPLACING FUSES 1.13±.020 28.7±.508 E D 1.88±.020 3.09 Max. 47.8±.508 78.49 B A 100V USE ONLY WITH 120V 250V FUSES 230V C DISCONNECT POWER 240V BEFORE REPLACING FUSES 5EHM1S & 5EFM1S (IEC Connector, DPST On/Off D Switch, Selectable Fuseholder) E B A USE ONLY WITH 250V FUSES C DISCONNECT POWER BEFORE REPLACING FUSES E D B A 3EXM1S & 3EZM1S (IEC Connector, DPST On/Off Switch, Selectable Fuseholder) 5EHM4 & 5EFM4 (IEC Connector, DPST On/Off Switch, G Thread Selectable Fuseholder) 6-32 x 1/4 1.13±.020 28.7±.508 100V USE ONLY WITH 120V 250V FUSES 230V C 1.88±.020 3.09 240V DISCONNECT POWER Max. BEFORE REPLACING FUSES 47.8±.508 78.49 E D USE ONLY WITH 250V FUSES C DISCONNECT POWER B BEFORE REPLACING FUSES A D E B 5EHM4S & 5EFM4S (IEC Connector, DPST On/Off A Switch, Voltage Selector, Selectable Fuseholder) 100V USE ONLY WITH 120V 250V FUSES C 230V 240V DISCONNECT POWER BEFORE REPLACING FUSES 3EXM4S & 3EZM4S (IEC Connector, DPST On/Off E D Switch, Voltage Selector, Selectable Fuseholder) B A G Thread 6-32 x 1/4 1.17±.020 29.7±.508 1.88±.020 3.09 Max. 47.8±.508 78.49 100V USE ONLY WITH 120V 250V FUSES 230V C DISCONNECT POWER 240V BEFORE REPLACING FUSES D Typical dimensions: E B Torque: 7 in. lb max. A Holes: .055 [1.40] Dia. ±.004 [±.10] except solder lug ground tap with wire wrap. Mounting Holes: .155 [3.94] Dia. All parts typical. Note: Mounting holes on tabs are countersunk and take a #6 flathead screw. 121 Catalog 1654001 Dimensions are in inches and Dimensions are shown for USA Cust. Svc.: 1-800-468-2023 www.cor.com Revised 03-04 millimeters unless otherwise reference purposes only. CORCOM Prods: 1-847-680-7400 www.tycoelectronics.com specified. Values in italics Specifications subject 1-508-992-4495 are metric equivalents. to change. Germany: 49-89-6089-0
Frequently asked questions
What makes Elite.Parts unique?

What kind of warranty will the 5EHM1 have?

Which carriers does Elite.Parts work with?

Will Elite.Parts sell to me even though I live outside the USA?

I have a preferred payment method. Will Elite.Parts accept it?

What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods