Elite.Parts chervon right Manufacturers chervon right C chervon right COOPER BUSSMANN chervon right BDH47
About product Specifications Datasheet FAQ

COOPER BUSSMANN BDH47

Image of COOPER BUSSMANN BDH47

Description

HANDLE FOR DISCONNECT SWITCH

Part Number

BDH47

Price

Request Quote

Manufacturer

COOPER BUSSMANN

Lead Time

Request Quote

Category

PRODUCTS - B

Specifications

Breaker Size

None

Color

Black

Defeater

Defeatable

Handle Shape/Style

Lever

Handle Type

Rotary Disconnect Switch

Locking

Padlockable

Marking

Off/On

Mounting

Cover

NEMA Rating

1, 12

Switch Size

40-100 Amp

Used On

BD

Datasheet

pdf file

Cooper Bussmann-BDH47-handle for disconnect switch-datasheet1-253630680.pdf

1390 KiB

Extracted Text

¤ Disconnect Switches Bussmann Page Selection Guide Fusible 2 Non-Fusible 3 Handles 4 Disconnect Switches Fusible (30-800A) Features 5-6 Components 7 Accessories 8 Non-Fusible (16-3150A) Features 9 Components 10-14 Accessories 15 Mounting Depths (Compact Disconnect) 16 Technical Data Fusible 17-18 Non-Fusible 19-20 Auxiliary Contact Timing Diagrams 21-27 Approximate Dimensions Fusible 28-29 Non-Fusible 30-34 Handles 35 Transfer & Bypass Switches 36-40 Get the latest, most up-to-date specification data on products listed in this catalog by calling Bussmann Information Fax. BIF is a simple to use automated fax response system. No need to wait for normal business hours; BIF is available around the clock for your convenience. All you need is a touch-tone telephone and a fax machine to get specification data when Bussmann you want it. Information Fax ~ A BIF document number is indicated with each product in 314.527.1450 this catalog. To get a detailed specification sheet simply call Bussmann 314-527-1450 and follow the prompts. In a matter of min- utes, a data sheet will be faxed to you. It’s that simple! Worldwide Web ~ http://www.bussmann.com © 1997 Cooper Industries, Inc. Bussmann Division Printed in U.S.A. 1 ® Bussmann Worldwide Circuit Protection Solutions North America’s leading supplier of fuses and fusible protection systems, Bussmann continues its 80-year history of blazing new trails of innovative technologies. Maker of the industry’s first truly global product line, each item is backed by an efficient worldwide network of distribution, customer service and technical support. Bussmann products include the most extensive circuit protection solutions approved for use in a variety of major standards: UL, CSA, IEC. . . Not to mention both European (DIN, British Standard) and North American styled fuses for a wide range of applications: industrial motor protection, power conversion, medium voltage, power distribution, telecommunications network equipment, electronics, and automotive. Manufacturing operations in the U.S., Denmark, and the United Kingdom have earned ISO 9000 certification. Bussmann customers are assured of only the utmost quality across every product line. Knowledgeable. Responsive. Customer focused. Bussmann continues to set the standard for circuit protection solutions around the world. This catalog is intended to present product data and provide technical information that will help the end user with design application. Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information contained in this catalog. Once a product has been selected, it should be tested by the user in all possible applications. ©1997 Cooper Industries, Bussmann Division Printed in the U.S.A. Headquarters Bussmann Denmark Cooper Industries 5 Literbuen Bussmann Division DK-2740 Skovlunde P.O. Box 14460 Copenhagen, Denmark St. Louis, Missouri 63178-4460, USA Telephone: 45 4485 0900 Telephone: 314 394 2877 Facsimile: 45 4485 0901 Facsimile: 800 544 2570 Bussmann France ® Bussmann Circuit Components Tour Mattei Bussmann 7300 West Wilson Avenue 207 Rue de Bercy Chicago, IL 60656-4793, USA 75587 Paris Cedex 12 Disconnect Switches Telephone: 708 867 4600 France Facsimile: 708 867 2211 Telephone: 33 1 4475 0033 Facsimile: 33 1 4475 0420 European Headquarters Bussmann Division Bussmann Germany Cooper (U.K.) Limited Frankfurter Landstrasse 19 Burton-on-the-Wolds 64546 Mörfelden Leicestershire LE12 5th, England Germany Telephone: 44 1509 882737 Telephone: 49 6105 951509 Facsimile: 44 1509 882786 Facsimile: 49 6105 951510 Bussmann Asia Pacific Bussmann India 331 North Bridge Road 2nd Floor, Unit #5 #03-02 Odeon Towers White House Singapore 188720 23-29, St. Marks Road Republic of Singapore Bangalore – 560-001 Telephone: 65 336 3610 India Facsimile: 65 336 4810 Telephone: 91 80 227 0893 Facsimile: 91 80 224 0124 Bussmann Australia Dock 5, Block X Bussmann Mexico 391 Park Road Arrow-Hart S.A. de C.V. P.O. Box 257 Poniente 148, No. 933 Regents Park, Sydney 02300 Mexico, D.F. Mexico NSW 2143, Australia Telephone: 52 5 587 0211 Telephone: 61 2 9743 8333 Facsimile: 52 5 567 4049 Facsimile: 61 2 9743 8070 Bussmann Brasil Bussmann do Brasil Ltda. Rodovia Santos Dumont, Km 23 Cruz das Almas Itu-Sao Paulo 13 300-000 Brasil Telephone: 55 11 7824 1856 Facsimile: 55 11 7824 1721 © Cooper Industries, Bussmann Division, Printed in U.S.A. Form No. BDS.1197 ¤ Disconnect Switches Bussmann Fusible Selection Guide Ampere Rating 30 60 100 200 400 600 800 Poles available 3, 4 2, 3, 4 2, 3, 4 2, 3, 4 2, 3, 4 2, 3, 4 2, 3, 4 † 3 Pole dimensions (inches) Width 4.17 6.89 7.48 10.25 11.18 14.68 14.68 Height 3.94 4.22 5.60 9.87 12.18 14.30 14.30 Depth 4.22 4.76 5.12 7.28 7.79 8.86 8.86 Fuse type J & CC J J & T J & T J & T J & T L Line & load fuse isolation X X X X X X X Auxiliary contacts X X X X X X X Terminal shrouds STD STD X X X X X Fuse covers STD X X STD STD STD STD 6 Pole kit X X X X X X X Transfer kit X X X X X X X Bypass kit � � � X X X X Mechanical interlock X � � X X X X NEMA 1, 3R, 12 handles Selector X —— —— —— —— —— —— Pistol X X X X X X X NEMA 4, 4X handles Pistol X X X X X X X Metallic � � � X X X X Flange-mounted operator X X X � � � � U.L. Listed (3 pole) X X X X X X X CSA Certified X X X X X X X IEC Ratings X X X X X X X Marked X X X X X X X † Includes terminals. X = Available � = Not available STD = Standard + + = Basic Switch Shaft Handle Complete Device (fusible) 1, 2 Basic switch catalog numbering system — fusible devices BDCF 30J6 Fusible device Fuse type BDCF—30A Amp rating BDF — 60-100A FD — 200-800A 1 Shaft and handle must be ordered separately. 2 Terminal lugs need to be ordered separately for 100A and above. 2 ¤ Disconnect Switches Bussmann Non-Fusible Selection Guide Ampere Rating 16 25 30 40 80 100 175 200 400 600 800 1200 1600 2000 3150 Frame size NF16 NF25 NF32 NF45 NF60 NF100 NF175 NF200A NF400 NF600A NF800A NF1200 NF1600 NF2000 NF3150 Poles available 3, 4 3, 4 3, 4 3, 4 3 3 2, 3, 4 2, 3, 4 2, 3, 4 2, 3, 4 2, 3, 4 2, 3, 4 2, 3, 4 2, 3, 4 2, 3, 4 † 3 Pole dimensions (inches) Width 1.4 1.4 1.4 2.1 2.08 3.06 7.86 8.64 10.23 11.90 14.29 14.29 18.42 18.42 18.42 Height 2.7 2.7 2.7 3.6 3.31 3.88 8.36 8.36 11.82 11.77 19.09 19.09 25.02 25.02 25.02 Depth 2.2 2.2 2.2 2.8 2.92 3.12 4.55 4.55 5.13 5.13 4.92 4.92 10.66 10.66 10.66 Visible blades � � � � � � X X X X X X X X X Auxiliary contacts X X X X X X X X X X X X X X X 6 Pole kit X X X X X X X X X X X X � � � Transfer kit X X X X X X X X X X X X � � � Bypass kit X X X X X X X X X X X X � � � Mechanical interlock � � � � � � X X X X X X X X X Terminal shrouds X X X X X X X X X X X X � � � * NEMA 1, 3R & 12 handles Selector X X X X X X � � � � � � � � � Pistol X X X X X X X X X X X X � � � NEMA 4 & 4X handles Pistol X X X X X X X X X X X X � � � Metallic � � � � � � � � X X X X X X X Flange-mounted operator � � � � � X � � � � � � � � � Door mounting kit X X X X � � � � � � � � � � � Toggle operator X X � � � � � U.L. Listed (3 pole) X X X X X X X X X X X X X X � CSA Certified X X X X X X X X X X X X X X � IEC Ratings X X X X X X X X X X X X X X X † Includes terminals. Compact switches (16-40A) are touch safe without terminal shrouds, but shrouds can be installed for extra protection. * X = Available � = Not available + + = Basic Switch Shaft Handle Complete Device 1, 2 Basic switch catalog numbering system — non-fusible devices CDNF 30 Non-fusible device Frame size CDNF - Compact Size (16-40A) BDNF - Standard Size (80-3150A) 1 Shaft and handle must be ordered separately. 2 Terminal lugs need to be ordered separately for 100A and above. 3 ¤ Disconnect Switches Bussmann Handles — Fusible and Non-Fusible Handles for Non-Fusible Switches Handles for Fusible Switches Grip Grip NEMA Length Catalog NEMA Length Catalog Style Type Color (Inches) Marking Number Style Type Color (Inches) Marking Number 30A 16-100A Selector 1 Blk — Off/On & O/l No No CDH1S Selector 1, 3R, 12 Blk — Off/On & O/l Yes No CDH3S Selector 1, 3R, 12 R/Y — Off/On & O/l Yes No CDH4S Selector 1 R/Y — Off/On & O/l No No CDH2S Selector 1, 3R, 12 Blk — Off/On & O/l Yes Yes CDH5S Selector 1, 3R, 12 Blk — Off/On & O/l Yes No CDH3S Selector 1, 3R, 12 R/Y — Off/On & O/l Yes No CDH4S Selector 1, 3R, 12 R/Y — Off/On & O/l Yes Yes CDH6S Pistol 1, 12 Blk 3.15 Off/On Yes Yes BDH47 Selector 1, 3R, 12 Blk — Off/On & O/l Yes Yes CDH5S Pistol 1, 12 R/Y 3.15 O/l Yes Yes BDH48 Selector 1, 3R, 12 R/Y — Off/On & O/l Yes Yes CDH6S Pistol 1, 12 Blk 3.15 Off/On Yes Yes BDH47 Pistol 1, 3R, 12 Blk 2.36 Off/On Yes Yes BDH99 Pistol 1, 3R, 12 R/Y 2.36 O/l Yes Yes BDH100 Pistol 1, 12 R/Y 3.15 O/l Yes Yes BDH48 Pistol 1, 3R, 4, 4X, 12 Blk 2.36 Off/On Yes No BDH102 Pistol 1, 3R, 12 Blk 2.36 Off/On Yes Yes BDH99 Pistol 1, 3R, 12 R/Y 2.36 O/l Yes Yes BDH100 Pistol 1, 3R, 4, 4X, 12 R/Y 2.36 O/l Yes No BDH103 Pistol 1, 3R, 4, 4X, 12 Blk 2.36 Off/On Yes No BDH102 60-100A Pistol 1, 3R, 4, 4X, 12 R/Y 2.36 O/l Yes No BDH103 Pistol 1, 12 Blk 3.15 Off/On Yes Yes BDH20* 175-200A Pistol 1, 3R, 12 Blk 2.36 Off/On Yes Yes BDH50* Pistol 1, 3R, 4, 4X, 12 Blk 2.36 Off/On Yes No BDH57* Pistol 1, 3R, 12 Blk 3.15 Off/On Yes Yes BDH64 Pistol 1, 3R, 4, 4X, 12 Blk 3.15 Off/On Yes No BDH67 200A 400A Pistol 1, 3R, 12 Blk 4.72 Off/On Yes Yes BDH53 Pistol 1, 3R, 12 Blk 4.72 Off/On Yes Yes BDH53 200-800A 400-1200A Pistol 1, 3R, 12 R/Y 5.71 O/l Yes Yes BDH11 Pistol 1, 3R, 12 Blk 5.71 Off/On Yes Yes BDH16 Pistol 1, 3R, 12 Blk 5.71 Off/On Yes Yes BDH16 Pistol 1, 3R, 4, 4X, 12 Blk 5.71 Off/On Yes No BDH35 Pistol 1, 3R, 4, 4X, 12 Blk 5.71 Off/On Yes No BDH35 Pistol 1, 3R, 12 R/Y 5.71 O/l Yes Yes BDH11 Pistol 1, 3R, 4, 4X, 12 R/Y 5.71 O/l Yes No BDH36 Metallic 1, 3R, 4, 4X, 12 Blk 8.66 Off/On Yes No BDH8 Pistol 1, 3R, 4, 4X, 12 R/Y 5.71 O/l Yes No BDH36 400-3150A *Consult factory for red, yellow, “O/l”. Metallic 1, 3R, 4, 4X, 12 Blk 8.66 Off/On Yes No BDH8 4 Padlock- able Defeat- able Padlock- able Defeat- able ¤ Disconnect Switches Bussmann Fusible Disconnect Switches More about the Compact 30A: 30-800 Amps • Compact size (2• narrower than present 30A fusible switch) Features: • J & CC class fuse clips • Compact, space saving design • DIN rail mounting • Complete line of fusible disconnect switches 30A • Fuseholder cannot be removed under load through 800A • Finger-protected fuse holder • J fusible switches (30-600A) • Rotary and variable depth handle mechanism for through- • T fusible switches (100-600A) the-door operation • L fusible switch (800A) • NEMA rated handles 1, 3R, 4, 4X & 12 • Rotary and variable-depth handle mechanisms for through- • Test position handle permits the operation of the auxiliary the-door operation contacts without main contacts being closed. The door can • NEMA rated handles 1, 3R, 4, 4X & 12 be opened in handle test position • Handles are lockable with three padlocks • Auxiliary contacts (up to eight auxiliary contacts, including • NEMA 1, 3R, 4 & 12 flange-mounted operators (30-100A) two auxiliary contacts/test contacts which are mounted in the • Type 1, 3R, 4 & 12 flange-mounted operators include inter- body of the switch) lock defeater for emergency maintenance purpose • NEMA 1, 3R & 12 handles are defeatable in “ON” position • 30-800A double break contacts • Auxiliary contacts • Terminal shrouds and fuse covers available for “touch-safe” protection Agency Approvals: U.L. Listed & CSA Certified (2 Pole & 3 Pole): U.L. 98 (CSA 22.2 No. 4): Suitable for use on service equipment, panel boards, switchboards, industrial control equipment, motor control centers, etc. (30-800A) U.L. File E155129 (30-100A), E155130 (200-800A) CSA File 58077M9 IEC 947-1 5 ¤ Disconnect Switches Bussmann Fusible Disconnect Switches — 30-800A, 600V Rotary Type Switches (30-800 Amps, 600V)* Maximum Horsepower Rating Amp Fuse Certification/ Catalog* BIF Rating Type 200V 208V 240V 480V 600V Listing Number Document 3 pole 30 CC 5 7.5 7.5 15 20 CSA, U.L. BDCF30CC6 1120 30 J 5 7.5 7.5 15 20 CSA, U.L. BDCF30J6 1 60A J 15 15 15 30 40 CSA, U.L. BDF60J6 1 1121 100A J 25 25 30 60 60 CSA, U.L. BDF100JT6 1 200 J 50 50 60 125 150 CSA, U.L. FD200J3 1 400 J 100 125 125 250 350 CSA, U.L. FD400J3 1122 1 600 J 150 150 200 400 500 CSA, U.L. FD600J3 800 L 200 200 250 500 600 CSA, U.L. FD800L3 Other pole configurations 2 pole 1 60 J 15 15 15 30 40 CSA, U.L. BDF60J62 1 100 J 25 25 30 40 50 CSA, U.L. BDF100JT62 1 200 J 50 50 60 125 150 CSA, U.L. FD200J2 — 1 400 J 100 125 125 250 350 CSA, U.L. FD400J2 1 600 J 150 150 200 400 500 CSA, U.L. FD600J2 800 L 200 200 250 500 600 CSA, U.L. FD800L2 4 pole 30 J 5 7.5 7.5 15 20 IEC BDCF30J64 30 CC 5 7.5 7.5 15 20 IEC BDCF30CC64 1 60 J 15 15 15 30 40 IEC BDF60J64 1 100 J 25 25 30 40 50 IEC BDF100JT64 — 1 200 J 50 50 60 125 150 IEC FD200J4 1 400 J 100 125 125 250 350 IEC FD400J4 1 600 J 150 150 200 400 500 IEC FD600J4 800 L 200 200 250 500 600 IEC FD800L4 *Catalog number includes switch only. Order handle, shaft and terminal lugs from tables on next page. 1 Class J fuses are standard. If a 600V Class T fuse is desired, select the necessary fuse adaptor from the Class T Fuse Adaptor Kit chart below. This provides the benefit of protecting downstream components U.L. Listed & CSA Certified: U.L. 98 (CSA 22.2 No. 4): Suitable for use on service equipment, against the damaging thermal and magnetic effects of short-circuit currents. Class CC fuses are branch circuit rated and can be used on panel boards, switchboards, industrial control equipment, motor con- branch circuits of electrical distribution systems. trol centers, etc. Class L (KRP-C) (30-800A), U.L. File E155129; (30-100A), E155130; (200-800A), Guide This 100% rated fuse is a high interrupting rating, current-limiting WPZX; CSA File 58077M9; IEC 947-1. device for the protection of service entrance equipment, feeder cir- Description cuits and circuit breakers. It may be applied at continuous currents Bussmann fusible disconnect switches allow the user to select the up to its ampere rating. The 4 second minimum time-delay provided appropriate fuse which best suits the tripping characteristic for the allows this fuse to pass normal surges and to coordinate with ground application. The various classes of fuses are described below. fault relays. Changing the fuse is convenient as the fuse links are isolated on both Class T Fuse Adaptor Kits for 600V Class J Switches the line and load side of the fuse. Fuse Classes Amp Rating Catalog Number Amp Rating Catalog Number Class J (LPS) 30A, 600V N/A 200A, 600V BDTA2 This fuse provides both time-delay for motor loads and a high degree of current-limitation. Suitable for the protection of service entrance 60A, 600V Contact Factory 400A, 600V BDTA4 equipment, feeder circuits, and branch circuits serving both motor 100A, 600V BDTA1 600A, 600V BDTA6 and non-motor loads. Class T (JJS) CE logo denotes compliance with European Union Low Voltage Directive Suitable for the protection of service entrance equipment, feeder cir- (50-1000 Vac, 75-1500 Vdc). Refer to BIF document #8002 or contact cuits, and branch circuits serving both motor and non-motor loads. Bussmann Application Engineering at 314-527-1270 for more information. Class CC (LP-CC) The Class CC fuse was developed specifically for a growing need in the industry: a compact, space saving branch circuit fuse for motor circuits. CC fuses can be used for protection of motors from �‰¢ to 10HP. A major feature of the CC fuse is that they are current-limiting. 6 ¤ Disconnect Switches Bussmann Fusible Disconnect Switch Components Handles — 30A Fusible Style NEMA Type Color Grip Length (Inches) Marking Padlockable Defeatable Catalog Number 30 Amps ( N0.20• ¯ 0.20•) Selector 1, 3R, 12 Blk — O/l and Off/On Yes No CDH3S Selector 1, 3R, 12 Red/Yel — O/l and Off/On Yes No CDH4S Selector 1, 3R, 12 Blk — O/l and Off/On Yes Yes CDH5S Selector 1, 3R, 12 Red/Yel — O/l and Off/On Yes Yes CDH6S Pistol 1, 12 Blk 3.15 Off/On Yes Yes BDH47 Pistol 1, 12 Red/Yel 3.15 O/l Yes Yes BDH48 Pistol 1, 3R, 12 Blk 2.36 Off/On Yes Yes BDH99 Pistol 1, 3R, 12 Red/Yel 2.36 O/l Yes Yes BDH100 Pistol 1, 3R, 4, 4X, 12 Blk 2.36 Off/On Yes No BDH102 Pistol 1, 3R, 4, 4X, 12 Red/Yel 2.36 O/l Yes No BDH103 Pistol 1 Blk 2.36 Off/On/Test Yes No BDH4 Pistol 1 Blk 2.00 O/I/Test Yes No BDH79 * * Mounts directly to switch. No shaft required. * Shafts Handles — 60-800A Fusible Mounting Depth Shaft Length (inches) Catalog Number ** Grip 30 Amps ( 0.20• ¯ 0.20•) Selector N NEMA Length Catalog 5.5 - 5.7 3.3 CDS85S Style Type Color (Inches) Marking Number 5.5 - 6.5 4.1 CDS105S 60-100 Amps ( N0.24• ¯ 0.24•) 5.5 - 7.1 4.7 CDS120S 5.5 - 7.5 5.1 CDS130S Pistol 1, 12 Blk 3.15 Off/On Yes Yes BDH20 6.3 - 9.4 7.1 CDS180S Pistol 1, 3R, 12 Blk 2.36 Off/On Yes Yes BDH50 9.1 - 12.2 9.8 CDS250S Pistol 1, 3R, 4X, 12 Blk 2.36 Off/On Yes No BDH57 12.2 - 15.4 13.0 CDS330S 200 Amps ( 0.47• ¯ 0.47•) N 30 Amps ( 0.20• ¯ 0.20•) Pistol N Pistol 1, 3R, 12 Blk 4.72 Off/On Yes Yes BDH53 6.89 - 7.48 5.91 BDS150P 200-800 Amps ( 0.47• ¯ 0.47•) N 7.67 - 8.27 6.69 BDS170 11.42 - 12.00 10.43 BDS265 Pistol 1, 3R, 12 Blk 5.71 Off/On Yes Yes BDH16 16.72 - 17.32 15.75 BDS400 Pistol 1, 3R, 4, 4X, 12 Blk 5.71 Off/On Yes No BDH35 60-100 Amps ( 0.24• ¯ 0.24•) N Pistol 1, 3R, 12 R/Y 5.71 O/l Yes Yes BDH11 5.50 - 8.50 5.90 BDS150 Pistol 1, 3R, 4, 4X, 12 R/Y 5.71 O/l Yes No BDH36 8.00 - 11.00 8.26 BDS210 Metallic 1, 3R, 4, 4X, 12 Blk 8.66 Off/On Yes No BDH8 11.00 - 14.00 11.41 BDS290 13.75 - 16.75 14.17 BDS360 16.54 - 19.69 16.93 BDS430 Terminal Lug Kits — Kit Includes 6 Lugs 200-400 Amps ( 0.47• ¯ 0.47•) N Amp Rating Wire Size Wire Type Kit Catalog Number 7.87 - 12.20 8.66 BDS220 30 & 60 Lugs come standard with switch 9.05 - 13.38 9.84 BDS250 10.22 - 14.54 11.00 BDS280 100 #14 - 2/0 Cu/Al BDTL24 12.0 - 16.32 12.78 BDS325 200 #6 - 300 kcmil Cu/Al BDTL25 14.78 - 19.10 15.56 BDS395 400 #2 - 600 kcmil Cu/Al BDTL26 17.53 - 21.85 18.31 BDS465 20.28 - 24.62 21.06 BDS535 600 & 800 (2) #2 - 600 kcmil Cu/Al BDTL27 600-800 Amps ( 0.47• ¯ 0.47•) N 10.04 - 12.83 9.84 BDS250 CE logo denotes compliance with European Union Low Voltage Directive 11.20 - 14.00 11.00 BDS280 (50-1000 Vac, 75-1500 Vdc). Refer to BIF document #8002 or contact 12.98 - 15.77 12.78 BDS325 Bussmann Application Engineering at 314-527-1270 for more information. 15.76 - 18.55 15.56 BDS395 18.51 - 21.30 18.31 BDS465 21.06 - 24.08 21.06 BDS535 Mounting depth is the distance from the outside of door to the disconnect switch mounting ** plate. Shaft can be cut to desired length. 7 Padlock- able Defeat- able ¤ Disconnect Switches Bussmann Fusible Disconnect Switch Accessories & Flange-Mounted Operators � Fuse Covers and Terminal Shrouds (line-side) Flange-Operated Switches Switch Type Amp Switch & Mechanism Fuse Covers Terminal Shrouds Rating Catalog Number Amp Fuse Catalog Catalog Rating Class Voltage Number Number 30 BDFLCF30J6-F 60 BDFLF60J6-F 60 J 600V BDFC60J Not Required 100 BDFLF100J6-F 100 J or T 600V BDFC100 BDTSF1 200 J or T 600V BDFC200* BDTSF2 † Shaft and handle must be ordered separately. 400 J 600V BDFC400* BDTSF4 600, 800 J or L 600V BDFC600* BDTSF6 *3-pole 30, 200-800 amp fusible switches come with the fuse cover as standard. Flange Switch Handles Terminal shrouds can also be used on the load side. NEMA Handle Rating Auxiliary Contacts — 30 Amps 4, 4X BDFNHS4 Type of Amp Catalog 12 BDFNHS12 Voltage Auxiliary Contact Rating Number Form C 6 250 BDAUX157 Flange Switch Shafts Aux. Contact Bracket BDAUXB Length Shaft Aux. Contact (NO) NEMA, A600, P600 BDAUXCB10 (inches) Catalog Number Aux. Contact (NC) BDAUXCB01 12 BDFHS12 17 BDFHS17 22.5 BDFHS22 Auxiliary Contacts — 60-800 Amps Switch Aux. Contact 1 NO & 1 NC 2 NO & 2 NC Voltage Amp Rating Amp Rating Catalog Number Catalog Number Door Hardware — NEMA 12 60 6 250 BDAUX7 BDAUX8 Item Catalog Number 100 6 250 BDAUX7 BDAUX8 Safety door latch, 2 point with 69 handle BDDHK 200-800 10 600 BDAUX1 BDAUX2 Roller for 3 point latch, add to FH-DHK BD3RL Conversion Kits for Combination Switches** CE logo denotes compliance with European Union Low Voltage Directive 30 Amp 60-100 Amp 200-800 Amp (50-1000 Vac, 75-1500 Vdc). Refer to BIF document #8002 or contact Description Catalog Number Catalog Number Catalog Number Bussmann Application Engineering at 314-527-1270 for more information. 6 Pole BDZW5 BDZW2 BDZW9 1 Transfer BDZW30 BDZW1 BDZW12 (2 switches with center OFF position) Bypass — — BDZW13 (3 switches with center OFF position) 2 Mechanical Interlock BDZW4 — BDZW3 (Mechanical interlock of two 2 BDZW14 switches) 2 BDZW15 Shaft Extension Coupler — — BDZW95 1 Includes metallic handle. 2 Distance between center line of shafts: BDZW3 = 11.819; BDZW14 = 9.849; BDZW15 = 19.689. See page 14 for descriptions of conversion kits. ** 8 ¤ Disconnect Switches Bussmann Non-Fusible Disconnect Switches 16-3150 Amps Features: Agency Approvals: • Compact, heavy-duty, space saving design U.L. 508 (CSA 22.2 No. 14): Suitable for use in equipment, • Complete line of non-fusible disconnect switches 16A machinery, or industrial control panels as a motor controller; through 3150A and are provided with horsepower and ampere ratings. • Convenient through-the-door operation (16-175A, 3 Pole), (16-40A, 4 Pole) • Rotary and variable-depth handle mechanisms for through- U.L. 98 (CSA 22.2 No. 4): Suitable for use on service the-door operation equipment, panel boards, switchboards, industrial • NEMA rated handles 1, 3R, 4, 4X & 12 control equipment, motor control centers, etc. (200-2000A, • NEMA 1, 3R & 12 handles are defeatable in “ON” position 2 & 3 Pole), (200-600A, 4 Pole) • Handles available with interlock defeater for emergency U.L. File 155129 (16-175A) maintenance purpose U.L. File 155130 (200-2000A) • Handles are lockable with three padlocks CSA File 58077M9 • DIN rail mountable switches (16-80A), base and door IEC 947-1, 3 mountable switches • Snap-on auxiliary contacts, power poles and additional poles • Terminal shrouds available for “touch-safe” protection 9 ¤ Disconnect Switches Bussmann Compact Disconnect Switches — 16-40A, 600V Select one of each + + 2 Shaft Handle Switch Non-Fusible, 16-40A, 600V Base & DIN Rail Mounted Switches 1 (16-40A, 600V) 3 pole Maximum Horsepower Rating Terminal Lugs Single Phase Three Phase Amp Wire Wire Certification/ Catalog Rating 120V 240V 200V 240V 480V 600V Size Type Listing Number 16 �‰“ 1.5 2 2 7.5 7.5 #18-#8 Cu CSA/U.L. CDNF16 25 �‰¢ 2 3 3 7.5 10 #18-#8 Cu CSA/U.L. CDNF25 30 1 3 5 5 10 15 #18-#8 Cu CSA/U.L. CDNF32 40 2 5 10 10 20 20 #14-#4 Cu CSA/U.L. CDNF45 CDNF32 CDNF45 Selector Handles Shafts for use with 2 CDH Selector Handles (M5 ¯ 5mm) NEMA Catalog 3 Ratings Color Padlockable Defeatable Number Length Catalog inches/mm Number All marked both O/l and OFF/ON 3.3/85 CDS85S 1 Blk CDH1S 4.1/105 CDS105S 1 R/Y CDH2S 4.7/120 CDS120S 1, 3R, 12 Blk • CDH3S 5.1/130 CDS130S 1, 3R, 12 R/Y • CDH4S CDH1S CDH6S 7.1/180 CDS180S 1, 3R, 12 Blk • • CDH5S 9.8/250 CDS250S 1, 3R, 12 R/Y • • CDH6S 13.0/330 CDS330S Pistol Handles Shafts for use with 2 Pistol Handles (M5 ¯ 5mm) NEMA Length Padlock- Defeat- Catalog 3 Ratings Color Marking mm able able Number Length Catalog inches/mm Number 1, 12 Blk Off/On 80 • • BDH47 5.9/150 CDS48P BDH47 1, 12 R/Y O/l 80 • • BDH48 6.7/170 CDS67P 1, 3R, 12 Blk Off/On 60 • • BDH99 10.4/265 CDS49P 1, 3R, 12 R/Y O/l 60 • • BDH100 15.8/400 CDS50P 1, 3R, 4, 4X, 12 Blk Off/On 60 • BDH102 19.7/500 CDS99P 1, 3R, 4, 4X, 12 R/Y O/l 60 • BDH103 Door Mounted Switches Selector Handles for Door Mounted Switches 1 (16-30A, 600V) 3 pole NEMA Catalog Maximum Horsepower Rating Terminal Lugs Ratings Color Padlockable Defeatable Number Single Phase Three Phase All marked both O/l and OFF/ON Amp Wire Wire Catalog Rating 120V 240V 200V 240V 480V 600V Size Type Number 1 Blk CDH7S 16 �‰“ 1.5 2 2 7.5 7.5 #18-#8 Cu CDNF16D 1 R/Y CDH8S 25 �‰¢ 2 3 3 7.5 10 #18-#8 Cu CDNF25D 1, 3R, 12 Blk • CDH9S 30 1 3 5 5 10 15 #18-#8 Cu CDNF32D 1, 3R, 12 R/Y • CDH10S Shafts not required with door mounted switches. 1 A snap-on fourth pole may be added. See Accessories. CE logo denotes compliance with European Union Low Voltage Directive 2 Door mounted switches do not require shafts. (50-1000 Vac, 75-1500 Vdc). Refer to BIF document #8002 or contact 3 For mounting depth please see page 16. Bussmann Application Engineering at 314-527-1270 for more information. 10 ¤ Disconnect Switches Bussmann Non-Fusible Disconnect Switches — 80-100A, 600V Rotary Type Switches (80-100 Amps, 600V) Maximum Horsepower Rating Wire Size 3 Pole Single Phase Three Phase Amp For Terminal Certification/ Catalog Rating 120V 200V 240V 200V 208V 240V 480V 600V Lugs Listing Number 80 3 7.5 10 15 15 20 40 50 #14 - #1 Cu CSA, U.L. BDNF60 100 5 10 15 20 20 25 50 60 #6 - 2/0 Cu CSA, U.L. BDNF100 Catalog number & price includes switch and lugs only. Order handles and shafts from tables below. Handles 80-100 Amps ( N0.20• ¯ 0.20•) Style NEMA Type Color Grip Length (Inches) Marking Padlockable Defeatable Catalog Number Selector 1, 3R, 12 Blk — O/l and Off/On Yes No CDH3S Selector 1, 3R, 12 Red/Yel — O/l and Off/On Yes No CDH4S Selector 1, 3R, 12 Blk — O/l and Off/On Yes Yes CDH5S Selector 1, 3R, 12 Red/Yel — O/l and Off/On Yes Yes CDH6S Pistol 1, 12 Blk 3.15 Off/On Yes Yes BDH47 Pistol 1, 12 Red/Yel 3.15 O/l Yes Yes BDH48 Pistol 1, 3R, 12 Blk 2.36 Off/On Yes Yes BDH99 Pistol 1, 3R, 12 Red/Yel 2.36 O/l Yes Yes BDH100 Pistol 1, 3R, 4, 4X, 12 Blk 2.36 Off/On Yes No BDH102 Pistol 1, 3R, 4, 4X, 12 Red/Yel 2.36 O/l Yes No BDH103 � Rotary Handles — Mounted Directly to Switch Switch Type Poles NEMA Type Color Marking Padlockable Defeatable Catalog Number BDNF60 3 1 Blk O/l Yes No BDH127 † No shaft required Toggle Type Switch (80-100 Amps, 600V) Maximum Horsepower Rating Wire Size 3 Pole Single Phase Three Phase Amp For Terminal Certification/ Catalog Rating 120V 200V 240V 200V 208V 240V 480V 600V Lugs Listing Number 80 3 7.5 10 15 15 20 40 50 #14 - #1 Cu CSA, U.L. BDNF60T 100 5 10 15 20 20 25 50 60 #6 -2/0 Cu CSA, U.L. BDNF100T Extended Shafts ( 0.20• ¯ 0.20•) N Accessories — 80-100 Amps For Handle Mounting Shaft Catalog Auxiliary Contacts — 80A Type Depth* Length Number Switch Auxiliary Amp Catalog Voltage 4.61 - 5.39 3.3 CDS85S Amp Rating Contact Rating Number 5.39 - 6.18 4.1 CDS105S 80 Aux. contact base — BDAUXB80 NEMA 1, 3R 5.98 - 6.77 4.7 CDS120S 80 Aux. contact (NO) NEMA A600, P600 BDAUXCA10 & 12 6.38 - 7.17 5.1 CDS130S 80 Aux. contact (NC) NEMA A600, P600 BDAUXCA01 Selector 8.35 - 9.13 7.1 CDS180S 11.10 - 11.89 9.8 CDS250S Auxiliary Contacts — 80-100A 14.25 - 15.04 13 CDS350S Switch Aux. Contact 1 NO & 1 NC 2 NO & 2 NC Voltage 6.89 - 7.48 5.91 BDS150P Amp Rating Amp Rating Catalog Number Catalog Number NEMA 1, 3R, 7.67 - 8.27 6.69 BDS170 4, 4X & 12 80 6 250 BDAUX79 BDAUX80 11.42 - 12.00 10.43 BDS265 Pistol 100 6 250 BDAUX52 BDAUX53 16.72 - 17.32 15.75 BDS400 Terminal Shrouds (Line side) *Mounting depth is the distance from the outside of the door to the disconnect switch mounting plate. Shaft can be cut to desired length. Amp Rating Catalog Number Agency Approvals: 40-175 Amps: U.L. 508, File 155129, 100 BDTS1 CSA 22.2 No. 14; 200-800 Amps: U.L. 98, File 155130, CSA Note: Terminal shrouds can also be used on the load side. 22.2 No. 4, Guide WPZX: CSA File 58077M9; IEC 947-1 11 ¤ Disconnect Switches Bussmann Non-Fusible Disconnect Switches — 175-600A, 600V Rotary Type Switches (175-600 Amps, 600V) Maximum Horsepower Rating Amp Certification/ Catalog Rating 200V 208V 240V 480V 600V Listing Number 3 Pole 175 30 30 40 75 100 CSA, U.L. BDNF175A 200 60 60 75 150 200 CSA, U.L. BDNF200A 400 100 100 125 250 350 CSA, U.L. BDNF400 600 150 150 200 400 500 CSA, U.L. BDNF600A 2 Pole 175 30 30 40 75 100 CSA, U.L. BDNF175A2 200 60 60 75 150 200 CSA, U.L. BDNF200A2 400 100 100 125 250 350 CSA, U.L. BDNF4002 600 150 150 200 400 500 CSA, U.L. BDNF600A2 4 Pole 175 30 30 40 75 100 IEC BDNF175A4 200 60 60 75 150 200 CSA, U.L. BDNF200A4 400 100 100 125 250 350 CSA, U.L. BDNF4004 600 150 150 200 400 500 CSA, U.L. BDNF600A4 Catalog number & price includes switch only. Order handles, shafts and terminal lugs from tables below. Handles Shafts Mounting Depth* Shaft Length Catalog Number 175-200 Amps ( N0.31• ¯ 0.31•) NEMA Length Catalog Style Type Color (Inches) Marking Number 4.72 - 8.66 5.51 BDS140 8.66 - 12.59 9.45 BDS240 175-200 Amps ( N0.31• ¯ 0.31•) 12.61 - 16.55 13.39 BDS340 Pistol 1, 12 Blk 3.15 Off/On Yes Yes BDH64 18.91 - 22.85 19.69 BDS500 Pistol 1, 3R, 4, 4X, 12 Blk 3.15 Off/On Yes No BDH67 400-600 Amps ( N0.47• ¯ 0.47•) 400 Amps ( N0.47• ¯ 0.47•) 6.15 - 7.75 4.21 BDS107 Pistol 1, 3R, 12 Blk 4.72 Off/On Yes Yes BDH53 6.15 - 10.07 6.54 BDS166 400-600 Amps ( N0.47• ¯ 0.47•) 6.49 - 10.82 7.28 BDS185 7.87 - 12.2 8.66 BDS220 Pistol 1, 3R, 12 Blk 5.71 Off/On Yes Yes BDH16 9.05 - 13.38 9.84 BDS250 Pistol 1, 3R, 4, 4X, 12 Blk 5.71 Off/On Yes No BDH35 10.22 - 14.54 11.02 BDS280 Pistol 1, 3R, 12 R/Y 5.71 O/l Yes Yes BDH11 12.0 - 16.32 12.80 BDS325 Pistol 1, 3R, 4, 4X, 12 R/Y 5.71 O/l Yes No BDH36 14.78 - 19.1 15.55 BDS395 Metallic 1, 3R, 4, 4X, 12 Blk 8.66 Off/On Yes No BDH8 17.53 - 21.85 18.31 BDS465 20.28 - 24.62 21.06 BDS535 Terminal Lug Kits — Kit Includes 6 Lugs Mounting depth is the distance from the outside of the door to the disconnect switch * Amp Rating Wire Size Wire Type Kit Catalog Number mounting plate. Shaft can be cut to desired length. 175 & 200 #6 - 300 kcmil Cu/Al BDTL25 400 #2 - 600 kcmil Cu/Al BDTL26 600 (2) #2 - 600 kcmil Cu/Al BDTL27 Agency Approvals: 40-175 Amps: U.L. 508, File 155129, CSA 22.2 No. 14; 200-800 Amps: U.L. 98, File 155130, CSA 22.2 No. 4 CSA File 58077M9; IEC 947-1 Accessories — 175-600A Terminal Shrouds (Line side) Auxiliary Contacts Amp Rating Catalog Number Switch Aux. Contact 1 NO & 1 NC 2 NO & 2 NC 175 & 200 BDTS2 Voltage Amp Rating Amp Rating Catalog Number Catalog Number 400 BDTS4 600 BDTS6A 175-200 10 600 BDAUX12 BDAUX13 400-600 10 600 BDAUX1 BDAUX2 Note: Terminal shrouds can also be used on the load side. CE logo denotes compliance with European Union Low Voltage Directive (50-1000 Vac, 75-1500 Vdc). Refer to BIF document #8002 or contact Bussmann Application Engineering at 314-527-1270 for more information. 12 Padlock- able Defeat- able ¤ Disconnect Switches Bussmann Non-Fusible Disconnect Switches — 800-3150A, 600V Switches (800-3150 Amps, 600V) Maximum Horsepower Rating Amp Certification/ Catalog Rating 200V 208V 240V 480V 600V Listing Number 3 pole 800 200 200 250 500 600 CSA/U.L. BDNF800A 1200 — — — — — CSA/U.L. BDNF1200 1600 — — — — — CSA/U.L. BDNF1600 2000 — — — — — CSA/U.L. BDNF2000 3150 — — — — — IEC BDNF31503 Other pole configurations 2 pole 800 200 200 250 500 600 CSA/U.L. BDNF800A2 1200 — — — — — CSA/U.L. BDNF12002 1600 — — — — — CSA/U.L. BDNF16002 2000 — — — — — CSA/U.L. BDNF20002 3150 — — — — — IEC BDNF31502 4 pole 800 200 200 250 500 600 IEC BDNF800A4 1200 — — — — — IEC BDNF12004 1600 — — — — — IEC BDNF16004 2000 — — — — — IEC BDNF20004 3150 — — — — — IEC BDNF31504 Handles — all padlockable Shafts 1 Mounting Depth Shaft Length Catalog Number 800-1200 Amps ( N0.47• ¯ 0.47•) Catalog NEMA Color Length Marking Number 7.4 - 8.6 4.2 BDS107 7.4 - 10.9 6.5 BDS166 800-3150 Amps ( N0.47• ¯ 0.47•) 7.9 - 11.6 7.3 BDS185 Pistol 9.3 - 13.0 8.7 BDS220 1, 3R, 12 Blk 5.71 Off/On • BDH16 10.4 - 14.2 9.8 BDS250 1, 3R, 12 R/Y 5.71 O/l • BDH11 11.6 - 15.3 11.0 BDS280 1, 3R, 4, 4X, 12 Blk 5.71 Off/On BDH35 13.7 - 17.1 12.8 BDS325 1, 3R, 4, 4X, 12 R/Y 5.71 O/l BDH36 16.2 - 19.9 15.6 BDS395 Metallic 18.9 - 22.6 18.3 BDS465 1, 3R, 4, 4X, 12 Blk 8.66 Off/On BDH8 21.7 - 25.4 21.1 BDS535 1600-3150 Amps ( N0.47• ¯ 0.47•) Terminal Lug Kits — Kit Includes 6 Lugs 13.37 - 23.1 12.8 BDS325 Amp Wire Wire Kit Catalog 16.15 - 23.8 15.6 BDS395 Rating Size Type Number 18.9 - 26.6 18.3 BDS465 800 (2) #2 - 600 kcmil Cu/Al BDTL30 21.65 - 29.3 21.1 BDS535 1200 (4) #2 - 600 kcmil Cu/Al BDTL28 1 Mounting depth is the distance from the outside of door to the 1600 (4) #2 - 600 kcmil Cu/Al BDTL28 disconnect switch mounting plate. Shaft can be cut to desired 2000 (8) #2 - 600 kcmil Cu/Al BDTL28/2 length. 3150 (8) #2 - 600 kcmil Cu/Al BDTL28/2 Agency Approvals: U.L. 98 Accessories — 800-3150 Amps U.L. File E101914, Guide WPZX Auxiliary Contacts CSA File LR58077, LR58247 Switch Aux. 1 NO & 2 NO & IEC 947-1 Amp Contact Voltage 1 NC 2 NC Rating Amp Rating Cat. No. Cat. No. CE logo denotes compliance with European Union 800-3150 10 600 BDAUX1 BDAUX2 Low Voltage Directive (50-1000 Vac, 75-1500 Vdc). Refer to BIF document #8002 or contact Bussmann Terminal Shrouds (Line side) Application Engineering at 314-527-1270 for more Amp Rating Catalog Number information. 800 BDTS8A 1200 BDTS12 13 Defeat- able ¤ Disconnect Switches Bussmann Flange-Operated, Non-Fusible Disconnect Switches 30-200A, 600V Flange-Operated Switch 1 Flange-Operated Switches Shafts Amperage Switch & Mechanism Length Shaft Rating Catalog Number (Inches) Catalog Number 30 BDFLNF30F 12 BDFHS12 60 BDFLNF60F 17 BDFHS17 100 BDFLNF100F 22.5 BDFHS22 175 BDFLNF175F Door Hardware — NEMA 12 200 BDFLNF200AF Item Catalog Number 1 Contact Bussmann for additional information. Safety door latch, 2 point with 69 handle. BDDHK Handles Roller for 3 point latch, add to FHDHK BD3RL NEMA Handle Type Catalog Number CE logo denotes compliance with European Union Low Voltage Directive 1, 3R, 4, 4X, 12 BDFHNHS4 (50-1000 Vac, 75-1500 Vdc). Refer to BIF document #8002 or contact Bussmann Application Engineering at 314-527-1270 for more information. 1, 3R, 12 BDFHNHS12 Conversion Kits — 16-3150A, 600V Conversion Kits for Combination Switches Catalog Numbers Description 16 - 100A 175 - 200A 400 - 1200A 1600 - 3150A 6 pole CDZW8 BDZW18 BDZW9 — Transfer — 1 CDZW6 BDZW20 BDZW12 (2 switches with center OFF position) Bypass CDZW17 BDZW21 BDZW13 — (3 switches with center OFF position) 2 Mechanical Interlock BDZW3 CDZW8 2 2 (Mechanical interlock of two switches) — BDZW19 BDZW14 BDZW15 2 BDZW15 Shaft Extension Coupler — — BDZW95 BDZW95 1 Includes metallic handle. 2 Distance between center line of shafts: BDZW3 - 11.819; BDZW14 - 9.849; BDZW15 - 19.689. Mechanical interlock of two Conversion kit descriptions standard switches 6 Pole This conversion kit, in conjunction with two This conversion kit prevents one switch from closing when the other switch is in the ON standard 3 pole switches, allows the switches to open or close simultaneously. Handle is position. Handle is not included. not included. Bypass (three standard switches with center Transfer (two standard switches with center OFF position) OFF position) This conversion kit operates three switches: Two This conversion kit, in conjunction with two CDZW6 switches in parallel and one changeover switch 3 pole switches, manually transfers power to allow power bypass. A 3 position handle is from one switch to another with a center OFF included. position. A 3 position handle is included. Switch Size Handle Part Number Switch Size Handle Part Number BDH37 BDH37 16-100A 16-100A NEMA 1 & 12 only NEMA 1 & 12 only 175-1200A BDH6 175-1200A BDH21 CE logo denotes compliance with European Union Low Voltage Directive (50-1000 Vac, 75-1500 Vdc). Refer to BIF document #8002 or contact Bussmann Application Engineering at 314-527-1270 for more information. 14 ¤ Disconnect Switches Bussmann Compact Disconnect Switches — Accessories Non-Fusible, 16-40A, 600V Auxiliary Contacts — Snap-On Mounting Catalog For Switches Description Amps Volts Number 1 NO CDNF16...45 Mounts on right hand 10 600 CDAUX10 side of switch (2 max.) Auxiliary Contacts 1 NC CDNF16...45 Mounts on left hand 10 600 CDAUX01 Mounted on CDNF32 and CDAUX10 side of switch (2 max.) CDNF45 Switches CDAUX01 1 1 Power Poles — Snap-On Mounting Additional Poles — Snap-On Mounting • Only one power pole per switch • Switch accepts one additional pole per side • Mounts on left or right side of switch • Mounts on left or right side of switch For Switches Catalog Number For Switches Catalog Number Fourth Pole Solid Neutral CDNF16...32 CDS32P CDNF16...32 CDN32P CDNF16...32D CDS32D CDNF16...32D CDN32D CDS32P CDNF45 CDS63P Manually Operated Neutral Late-Break/Early Make CDNF16...32 CDD32P CDS63P CDNF16...32 CDL32P CDNF16...32D CDD32D CDNF16...32D CDL32D Ground Terminal CDNF16...32 CDE32P CDNF16...32D CDE32D 2 Terminal Shrouds — Snap-On Mounting Bypass (three standard switches with For Switches Catalog Number center OFF position) For 3-Pole Switches CDNF16...32 CDTS32T3 This conversion kit operates three switches: Two CDTS32T3 CDNF45 CDTS63T3 switches in parallel and one changeover switch to CDTS63T3 For Single Pole allow power bypass. A 3 position handle is CDAUX32P CDTS32T1 included, (NEMA 1 & 12 only.) CDAUX63P CDTS63T1 Conversion Kits for 2 Combination Switches Description Catalog Number 3 6 Pole CDZW8 Transfer 4 CDZW6 (2 switches with center OFF position) Bypass 4 CDZW17 CDZW8 6 Pole (3 switches with center OFF position) This conversion kit, in conjunction with two standard 3 pole switches, allows the switches Transfer (two standard switches with to open or close simultaneously. Handle is not center OFF position) included. This conversion kit, in conjunction with two 3 pole switches, manually transfers power from one switch to another with a center OFF position. A 3 position handle is included. (NEMA 1 & 12 only). CDZW6 CE logo denotes compliance with European Union Low Voltage Directive (50-1000 Vac, 75-1500 Vdc). Refer to BIF document #8002 or contact Bussmann Application Engineering at 314-527-1270 for more information. 1 Switch accepts one power pole or one additional pole per side. Only one power pole per switch. 2 Switches are not included. 3 One shaft is included. 4 Shafts included. 15 I ON O I O ® ® Strömberg IEC 947-3 Ue/V 415 500 690 Ith 16A AC-22A Ie/A 16 16 16 50...60Hz AC-23A Ie/A 14 14 12 ¤ Disconnect Switches Bussmann Compact Disconnect Switches — Mounting Depths Non-Fusible, 16-40A, 600V Shaft Shaft Length Mounting Depth Mounting Depth Shaft Dimensions Switch Sizes Handles Catalog Number Inches/mm Inches mm M mm CDS85S 3.3/85 4.2 – 5.0 106 – 126 CDS105S 4.1/105 5.0 – 5.8 126 – 146 CDS120S 4.7/120 5.6 – 6.4 141 – 161 CDNF16–32 CDH1S & CDH2S CDS130S 5.1/130 6.0 – 6.7 151 – 171 5 CDS180S 7.1/180 7.9 – 8.7 201 – 221 CDS250S 9.8/250 10.7 – 11.5 271 – 291 CDS330S 13.0/330 13.8 – 14.6 351 – 371 CDS85S 3.3/85 3.6 – 4.3 92 – 110 CDS105S 4.1/105 4.4 – 5.1 112 – 130 CDS120S 4.7/120 5.0 – 5.7 127 – 145 CDNF16–32 CDH3S-6S CDS130S 5.1/130 5.4 – 6.1 137 – 155 5 CDS180S 7.1/180 7.4 – 8.1 187 – 205 CDS250S 9.8/250 10.1 – 10.8 257 – 275 CDS330S 13.0/330 13.3 – 14.0 337 – 355 CDS48P 5.9/150 6.2 – 6.7 157 – 171 CDS67P 6.7/170 7.0 – 7.5 177 – 191 CDNF16–32 Pistol 5 CDS49P 10.4/265 10.7 – 11.3 272 – 286 CDS50P 15.8/400 16.0 – 16.6 407 – 421 CDS85S 3.3/85 4.9 – 5.6 124.5 – 142.5 CDS105S 4.1/105 5.7 – 6.4 144.5 – 162.5 CDS120S 4.7/120 6.3 – 7.0 159.5 – 177.5 CDNF45 CDH1S & CDH2S CDS130S 5.1/130 6.7 – 7.4 169.5 – 187.5 5 CDS180S 7.1/180 8.6 – 9.4 219.5 – 237.5 CDS250S 9.8/250 11.4 – 12.1 289.5 – 307.5 CDS330S 13.0/330 14.6 – 15.3 369.5 – 387.5 CDS85S 3.3/85 4.4 – 5.0 110.5 – 126.5 CDS105S 4.1/105 5.1 – 5.8 130.5 – 146.5 CDS120S 4.7/120 5.7 – 6.4 145.5 – 161.5 CDNF45 CDH3S-6S CDS130S 5.1/130 6.1 – 6.8 155.5 – 171.5 5 CDS180S 7.1/180 8.1 – 8.7 205.5 – 221.5 CDS250S 9.8/250 10.9 – 11.5 275.5 – 291.5 CDS330S 13.0/330 14.0 – 14.7 355.5 – 371.5 CDS48P 5.9/150 6.9 – 7.4 175 – 187 CDS67P 6.7/170 7.7 – 8.1 195 – 207 CDNF45 Pistol 5 CDS49P 10.4/265 11.4 – 11.9 290 – 302 CDS50P 15.8/400 16.7 – 17.2 425 – 437 IEC Utilization Categories Utilization Category Nature of Current Typical Applications Frequent Operation Infrequent Operation AC-20A AC-20B • Connecting and disconnecting under no-load conditions AC-21A AC-21B • Switching of resistive loads including moderate overloads Alternating Current AC-22A AC-22B • Switching of mixed resistive and inductive loads, including AC-23A AC-23B moderate overloads • Switching of motor loads or other highly inductive loads DC-20A DC-20B • Connecting and disconnecting under no-load conditions DC-21A DC-21B • Switching of resistive loads including moderate overloads Direct Current DC-22A DC-22B • Switching of mixed resistive and inductive loads, including DC-23A DC-23B moderate overloads (e.g., shunt motors) • Switching of highly inductive loads (e.g., series motors) Rated Thermal Current No. Mechanical Operations No. Mechanical Operations 0-50A 10,000 2,000 Category AC-23 includes occasional switching of individual motors. The switching of capacitors or tungsten filament lamps shall be subject to agreement between manufacturer and user. 16 ¤ Disconnect Switches Bussmann Technical Data — Fusible, 30-800 Amps U.L. & CSA Ratings Ampere Rating 30 60 100 200 400 600 800 2 pole — U.L. 98 U.L. 98 U.L. 98 U.L. 98 U.L. 98 U.L. 98 U.L. Standard 3 pole U.L. 98 U.L. 98 U.L. 98 U.L. 98 U.L. 98 U.L. 98 U.L. 98 4 pole — — — — — — — Short-circuit rating with fuse kA 100 100 100 100 100 100 100 Fuse size A 30 60 100 200 400 600 800 Fuse class J/CC J/T J/T J/T J/T J/T T/L — Electrical endurance 6,000 6,000 6,000 6,000 1,000 1,000 1,000 Mechanical endurance 10,000 10,000 8,000 6,000 6,000 6,000 — 200V 5 15 25 50 100 150 200 Maximum 208V 7.5 15 25 50 125 150 200 Horsepower 240V 7.5 15 30 60 125 200 250 Ratings 480V 15 30 60 125 250 400 500 600V 20 40 60 150 350 500 600 IEC Ratings Ampere Rating 30 60 100 200 400 600 800 Dielectric strength 50 Hz, 1 min kV 10 8 8 10 10 10 10 Rated impulse withstand voltage kV 12 12 12 12 12 12 12 Rated thermal current in ambient 40°C/in open air A/W 32/3.5 63/7.5 125/12 250/32 400/45 630/60 800/65 1 Max. fuse power dissipation in enclosure A/W 32/3.5 63/7.5 125/12 250/23,250/27 400/34,360/37 600/45,570/50 720/55 In enclosure with solid links A 32 7.5 125 315 450 700 900 2 With minimum cable cross section Cu mm 6 16 50 120 240 2 x 185 2 x 240 Rated operational voltage AC-20 and DC-20 V 1,000 750 750 1,000 1,000 1,000 1,000 Rated operational current, AC-21A up to 500V A 32 63 125 250 400 630 800 2 2 690V A 32 63 125 250 400 630 800 Rated operational current, AC-22A up to 500V A 32 63 125 250 400 630 800 2 2 690V A 32 63 125 250 400 630 800 Rated operational current, AC-23A up to 500V A 32 63 125 250 400 630 720 2 2 690V A 32 40 50 250 400 630 720 4 Rated operational current/poles in series 48V A 32/2 — — 250/2 400/2 630/2 800/2 DC-21A 100/220V A 32/2 63/3 125/3 250/2 400/2 630/2 800/2 2 440V A 32/4 63/4 125/4 250/2 400/2 630/2 800/2 500-750V A — — — 250/3 400/3 630/3 800/3 1000V A — — — 250/4 400/4 630/4 800/4 4 Rated operational current/poles in series 48V A 32/2 — — 250/2 400/2 630/2 800/2 DC-22A 100/220V A 32/2 63/3 125/3 250/2 400/2 630/2 800/2 2 440V A 32/4 63/4 125/4 250/2 400/2 630/2 800/2 500-750V A — — — 250/3 400/3 630/3 800/3 1000V A — — — 250/4 400/4 630/4 800/4 4 Rated operational current/poles in series 48V A 32/2 — — 250/2 400/2 630/2 800/2 DC-23A 110/220V A 32/2 63/3 125/3 250/2 400/2 630/2 800/2 2 440V A 32/4 — 100/4 250/2 400/2 630/2 800/2 500-750V A — — — 250/3 400/3 630/3 800/3 1000V A — — — — — 630/4 800/4 3 Rated operational power, AC-23 230V kW 8 15 30 70 110 180 200 —The kW ratings are accurate for 3-phase 400V kW 14 30 55 132 210 315 350 1500 R.P.M. standard asynchronous motors 415V kW 15 30 55 140 230 340 380 500V kW 18 30 70 170 280 400 470 690V kW 25 30 45 230 330 540 600 1 Ambient temperature 60°C: derating 20%. Mounting on “ceiling”: derating 10%. Mounting on wall, horizontal fuses: derating 8%. 2 Utilization category B. 3 Some fuse links limit these figures further. Starting current characteristics must be considered separately. 4 Use 4-pole switches with 2 + 2 parallel contacts in series. Figure 1 17 LOAD ¤ Disconnect Switches Bussmann Technical Data — Fusible, 30-800 Amps IEC Ratings Ampere Rating 30 60 100 200 400 600 800 Rated breaking capacity in category AC-23 up to 500V A 256 504 800 2,000 3,200 5,760 5,760 690V A 256 320 405 2,000 3,200 5,760 5,760 Rated breaking capacity/poles in series up to 220V A 128/2 256/3 640/3 1,000/2 1,600/2 3,200/2 3,200/2 in category DC-23 400V A 128/4 — 400/4 1,000/2 1,600/2 3,200/2 3,200/2 500-750V A — — — 1,000/3 1,600/3 3,200/3 3,200/3 1000V A — — — — — 3,200/4 3,200/4 Rated conditional short-circuit current RMS 80kA, 415V kA 9 12 23 40 40 75 75 and corresponding max. allowed cut-off current, peak-values 100kA, 500V kA 7.5 9 17 40 40 75 75 —The cut-off currents refer to single phase fuse tests 50kA, 690V kA 6 8 14 35 35 60 —Fuse selection tables on request Rated short-time withstand current, 1s. RMS -value kA 1 2 5 8 10 16 16 Rated capacitor power 400V kVAr 15 30 50 105 180 250 310 —The capacitor rating of the switch-fuse is limited by the fuse link 415V kVAr 15 32 55 115 200 270 340 690V kVAr 25 50 90 190 325 450 550 Power loss/pole With rated current, without fuse W 2 4 5 11 30 55 77 Mechanical endurance Divide by two for operation cycles Oper 20,000 20,000 20,000 16,000 16,000 10,000 10,000 Fuse types, IEC 269-2 DIN 43620 — 00 00 0-1 0-2 3 3 NFC 14 x 51 14 x 51 22 x 58 0-1 0-2 3 — BS88 A1.F1 A2-A3 A2-A4AB1-B2 B1-B4 B1-B4 C1-C2 C1-C3 –size/distance of fuse link bolts– mm M4/44.5 M5/73 M5/73, M8/94 M8/111 M8/111 M10/133, 184 M10/133, 184 Weight without accessories 3-pole switch fuses kg 0.7 1.6 1.8 6.9 7.8 15.5 17.0 4-pole switch fuses kg 0.9 1.9 2.3 7.9 8.8 19.0 21.0 2 Built-in terminal size Cu mm 0.5...10 2.5…25 Terminal bolt size Metric thread diameter x length mm M8 x 25 M10 x 40 M10 x 40 M12 x 40 M12 x 40 Terminal tightening torque Counter torque required Nm 2 5 15…22 30…44 30…44 50…75 50…75 Fuse-links bolts tightening torque Nm 2 3.5 M5:3.5/M8:10 15 15 40 40 Operating torque Typical for 3-pole switch fuses Nm 3 3 5 22 22 28 28 18 ¤ Disconnect Switches Bussmann Technical Data — Non-Fusible, 16-3150 Amps U.L. & CSA Ratings Ampere Rating 16 25 32 40 80 100 175 200 400 600 800 1200 1600 2000 3150 2 Pole — — — — — — — U.L. 98 U.L. 98 U.L. 98 U.L. 98 U.L. 98 U.L. 98 U.L. 98 U.L. Standard 3 Pole U.L. 508 U.L. 508 U.L. 508 U.L. 508 U.L. 508 U.L. 508 U.L. 508 U.L. 98 U.L. 98 U.L. 98 U.L. 98 U.L. 98 U.L. 98 U.L. 98 4 Pole U.L. 508 U.L. 508 U.L. 508 U.L. 508 U.L. 98 U.L. 98 U.L. 98 Short-circuit rating with fuse kA 10/5 10/5 10/5 10/5 10 100 100 100 100 100 100 100 100 100 Fuse size A 30 30 30 60 110 110 200 200 600 600 1,200 1,200 2,000 2,000 Fuse class CC, J, T, RK1/RK5 H or K J RK5 RK5 RK5 RK5 L L L L Short-circuit rating with MCCB kA — — — — — — 25 25 50 50 50 50 65 65 — 200V 2 3 5 10 15 20 30 60 100 150 200 — — — Maximum 208V 2 3 5 10 15 20 30 60 100 150 200 — — — Horsepower 240V 2 3 5 10 20 25 40 75 125 200 250 — — — Ratings 480V 7.5 7.5 10 20 40 50 75 150 250 400 500 — — — 600V 7.5 10 15 20 50 60 100 200 350 500 600 — — — Electrical endurance 6,000 6,000 6,000 6,000 6,000 6,000 6,000 6,000 1,000 1,000 1,000 1,000 1,000 1,000 Mechanical endurance 6,000 6,000 6,000 6,000 6,000 6,000 6,000 8,000 6,000 6,000 6,000 6,000 6,000 6,000 IEC Ratings Ampere Rating 16 25 32 40 80 100 175 200 400 600 800 1200 1600 2000 3150 Rated insulation voltage and operational voltage, AC 20 and DC 20 V 750 750 750 750 690 690 1,000 1,000 1,000 1,000 1,000 1,000 1,000 1,000 1,000 Rated impulse withstand voltage kV 8 8 8 8 8 8 12 12 12 12 8 8 8 8 8 Rated Thermal Current I : th AC 20 and DC 20 open A 25 32 40 50 100 125 250 350 630 800 1,250 1,600 2,500 3,150 3,150 40°C enclosed A 25 32 40 50 80 125 200 315 630 720 1,250 1,600 2,300 2,600 2,600 60°C enclosed A 25 32 40 50 63 100 175 260 500 600 1,000 1,250 1,950 2,300 2,300 Rated Operational Currents: 4 4 4 AC21A 500V A 16 25 32 45 80 125 200 315 630 800 1,250 1,600 2,500 3,150 3,150 4 4 4 690V A 16 25 32 45 80 125 200 315 630 800 1,250 1,600 2,500 3,150 3,150 5 1000V A — — — — — — 200 315 630 — — — — — — 4 4 4 AC22A 500V A 16 25 32 45 80 125 200 315 630 800 1,250 1,600 1,600 1,600 1,600 690V A 16 25 32 45 80 80 200 315 630 800 — — — — — 5 1000V A — — — — — — 200 250 400 — — — — — — 4 4 4 AC23A 415V A 16 20 23 30 63 75 200 315 630 720 800 800 800 800 800 4 4 4 500V A 16 20 23 30 45 56 200 315 580 600 800 800 800 800 800 6 6 690V A 8 11 12 20 40 35 200 315 350 350 — — — — — 5 1000V A — — — — — — 125 125 200 200 — — — — — 1 1 DC21A 48V A 80 125 200 315 630 800 1,250 1,600 1,600 1,600 1,600 3-poles in series 16-100A 110V A 80 125 200 315 630 800 1,250 1,600 1,600 1,600 1,600 2-poles in series 175-3150A 220V A 80 — 200 315 630 800 1,250 1,600 1,600 1,600 1,600 2 440V A — — 200 315 — — — — — — — 3 750V A — — 200 315 — — — — — — — 1 1 DC22A 48V A 80 75 200 315 630 800 — — — — — 3-poles in series 16-100A 110V A 80 50 200 315 630 630 — — — — — 2-poles in series 7 7 7 7 7 175-3150A 220V A 50 — 200 315 400 500 — — — — — 2 440V A — — 200 315 400 500 — — — — — 3 750V A — — 200 315 — — — — — — — 1 1 DC23A 48V A 80 75 200 315 — — — — — — — 3-poles in series 16-100A 110V A 35 50 200 315 630 800 — — — — — 2 7 7 7 7 7 2-poles in series 175-3150A 220V A 25 — 200 315 630 630 — — — — — 3 440V A — — 200 315 400 400 — — — — — 3 750V A — — 200 315 — — — — — — — 3 5 1 Four poles in series IEC 408 Two sets of parallel poles in series (Figure 1) 4 6 IEC 947-3, utilization category B, infrequent Size 4 2 operation Three poles in series (Figure 2) 7 Available upon request Figure 1 Figure 2 19 LOAD LOAD ¤ Disconnect Switches Bussmann Technical Data — Non-Fusible, 16-3150 Amps IEC Ratings Ampere Rating 16 25 32 40 80 100 175 200 400 600 800 1200 1600 2000 3150 Rated operational power 230V kW 3 4 5.5 7.5 18.5 22 55 90 180 200 250 250 250 250 250 AC23 400/415V kW 7.5 9 11 15 30 37 90 160 315 355 400 400 400 400 400 The kW-ratings are accurate 500V kW 7.5 9 11 15 30 37 132 200 355 400 450 450 450 450 450 12 12 for three-phase 1500 r.p.m. 690V kW 7.5 9 11 15 30 30 170 250 355 355 — — — — — standard asynchronous motors. 8 5 5 5 Short-circuit current with kA 50 50 50 50 50 50 100 100 80 150 80 50 50 50 50 50 11 back-up fuses of size A 25 32 40 50 100 125 400 400 630 800 800 1,000 1,250 1,250 1,250 1,250 Rated voltage Ue V/V 415 415 415 415 415/690 500/690 500/690 500/690 500/690 500/690 690 690 690 690 690 Rated conditional short-circuit current kA/kA 50 50 50 50 10/18 10/10 100/50 100/50 100/50 100/50 45 45 50 50 50 13 13 Max. allowed fuse size, type OFAA A/A 16 32 40 50 100/63 80/63 400 400 800 800 — — — — — Max. allowed cut-off current, peak value kA/kA 4 4.3 4.6 5.5 5.8/5.5 4.2/5.6 30 30 62 62 — — — — — Rated short-circuit making capacity, prospective peak value, I kA 1 1 1 1 2.7 3.6 35/35 35 80 80 95 95 115 115 115 cm Rated short-time withstand current, RMS l 0.2 kA 1.5 2.5 17 17 38 38 45 45 50 50 50 cw 5 1.0 kA 1 1 1 1 1.5 2.5 8 8 17 17 33 33 37 37 37 5 AC breaking capacity 415V A 128 160 184 240 510 600 1,600 2,520 5,760 5,780 6,400 6,400 6,400 6,400 6,400 Pf 0.35 500V A 128 160 184 240 400 450 1,600 2,520 4,800 4,800 6,400 6,400 6,400 6,400 6,400 6 6 10 10 690V A 54 88 96 150 320 280 1,600 2,520 2,800 2,500 2,500 4,800 4,800 — — 11 1000V A — — — — — — 1,000 1,000 1,200 1,200 — — — — — DC breaking capacity 9 9 48V A 325 — 1,260 1,260 — — — — — — — 4 9 9 L/R = 8ms, 3-poles 110V A 550 300 1,260 1,260 — — — — — — — 4 1 1 1 1 1,4 1,4 1,4 1,4 1,4 in series 220V A 215 200 1,260 1,260 1,600 2,000 1,900 2,600 2,600 2,600 2,600 4 440V A 30 — 1,260 1,260 1,600 2,000 — — — — — 2 3 3 750V A — — 1,260 1,260 — — — — — — — Electrical endurance at rated operational current. 7 7 7 pf 0.65 operation cycles 3,000 3,000 3,000 3,000 1,500 1,500 1,000 1,000 1,000 500 500 500 100 100 100 Mechanical endurance operations 20,000 20,000 20,000 20,000 20,000 16,000 16,000 16,000 10,000 10,000 10,000 10,000 6,000 6,000 6,000 Weight 3-pole lb .24 .24 .24 .60 .66 .99 6.17 13.66 13.33 35.93 38.58 143 143 143 143 4-pole lb .33 .33 .33 .77 .72 1.38 7.93 7.93 16.75 16.75 45.19 49.60 165 165 165 Power loss per one pole W .3 .6 1.0 1.4 7 7 3.5 8.5 22 40 40 67 90 140 140 11 Operating torque Nm 1 1 1 1.2 2.0 1.6 8.2 8.2 21 21 21 21 50 50 50 Suitable conductor 2 cross section Cu mm .75…10 .75…10 .75…10 1.5…25 1.5…35 10…70 8 x 25 10 x 30 12 x 40 12 x 40 12 x 60 12 x 60 12 x 60 12 x 60 12 x 60 1 6 9 Two poles in series Pf 0.95 One pole 2 7 10 Three poles in series (Figure 2) IEC 947-3, utilization category B, infrequent Pf 0.65 operation 3 11 Four poles in series IEC 408 8 With circuit breaker, time-delay 0.5 sec. max. 4 12 L/R = 2.5 ms Available upon request (in closed position) 5 13 With circuit breaker, time-delay 1 sec. max. Size 4 Figure 1 Figure 2 20 LOAD LOAD ¤ Disconnect Switches Bussmann Technical Data — Auxiliary Contact Timing Diagrams Fusible — 30 Amps 0° 30° 60° 90° Legend � Main contact ˆ ON ON closing O 1`NO auxiliary contact opening O 1˜ II ´NC auxiliary contact¯ OFF OFF O O OFF ON O I Contacts closing 1 Main contacts close 2 NO auxiliary contacts close 3 NC auxiliary contacts open Contacts opening 4 Main contacts open 5 NO auxiliary contacts open 6 NC auxiliary contacts close 30 Amps 0° 30° 60° 90° Catalog Auxiliary Contact Number Contact Configuration Main contact BDAUX157 1 NO & 1 NC BDCF30 BDAUXCB01 1 NO NO auxiliary closing O 1 contact opening O 1 BDAUXCB10 1 NC NC auxiliary contact OFF BDAUX157 ON O I 0° 30° 60° 90° Main contact NO auxiliary closing O 1 contact opening O 1 NC auxiliary contact OFF ON BDAUXCB01 O I BDAUXCB10 21 ¤ Disconnect Switches Bussmann Technical Data — Auxiliary Contact Timing Diagrams Fusible — 60-100 Amps 60-100 Amps 0° 30° 60° 90° Contact Catalog Auxiliary Configuration Main contact Numbers Contact Form C BDF60 & BDAUX7 1 NO & 1 NC closing O 1 NO auxiliary opening O 1 contact BDF100 BDAUX8 2 NO & 2 NC NC auxiliary ON contact OFF ON I O I OFF O 22 ¤ Disconnect Switches Bussmann Technical Data — Auxiliary Contact Timing Diagrams Fusible — 200-800 Amps 200-400 Amps 0° 30° 60° 90° Catalog Auxiliary Contact Numbers Contact Configuration Main contact FD200 & BDAUX1 1 NO & 1 NC NO auxiliary closing O 1 FD400 BDAUX2 2 NO & 2 NC contact opening O 1 NC auxiliary ON contact OFF ON I O I OFF O 600-800 Amps Catalog Auxiliary Contact 0° 30° 60° 90° Numbers Contact Configuration Main contact FD600 & BDAUX1 1 NO & 1 NC FD800 BDAUX2 2 NO & 2 NC closing O 1 NO auxiliary opening O 1 contact NC auxiliary contact OFF ON O I 23 ¤ Disconnect Switches Bussmann Technical Data — Auxiliary Contact Timing Diagrams Non-Fusible — 16-40 Amps 0° 30° 60° 90° Legend � Main contact ˆ ON closing O 1`NO auxiliary contact opening O 1˜ I ´NC auxiliary contact¯ OFF O OFF ON O I Contacts closing 1 Main contacts close 2 NO auxiliary contacts close 3 NC auxiliary contacts open Contacts opening 4 Main contacts open 5 NO auxiliary contacts open 6 NC auxiliary contacts close 16-30 Amps 0° 30° 60° 90° Catalog Auxiliary Contact Number Contact Configuration Main contact CDAUX10 NO CDNF16-32 CDAUX01 NC closing O 1 NO auxiliary opening O 1 contact NC auxiliary contact OFF ON O I 40 Amps 0° 30° 60° 90° Catalog Auxiliary Contact Number Contact Configuration Main contact CDAUX10 NO CDNF45 CDAUX01 NC closing O 1 NO auxiliary contact opening O 1 NC auxiliary contact OFF ON O I 24 ¤ Disconnect Switches Bussmann Technical Data — Auxiliary Contact Timing Diagrams Non-Fusible — 80 Amps 80 Amps 0° 30° 60° 90° Catalog Auxiliary Contact Number Contact Configuration Main contact BDAUXCA10 NO BDNF60 BDAUXCA01 NC closing O 1 NO auxiliary contact opening O 1 NC auxiliary contact ON OFF ON I O I OFF O 80 Amps Contact 0° 30° 60° 90° Catalog Auxiliary Configuration Number Contact Form C Main contact BDAUX79 1 NO & 1 NC BDNF60 BDAUX80 2 NO & 2 NC NO auxiliary closing O 1 contact opening O 1 NC auxiliary contact OFF ON O I 25 ¤ Disconnect Switches Bussmann Technical Data — Auxiliary Contact Timing Diagrams Non-Fusible — 100-200 Amps 100 Amps Contact 0° 30° 60° 90° Catalog Auxiliary Configuration Number Contact Form C Main contact BDAUX52 1 NO & 1 NC BDNF100 BDAUX53 2 NO & 2 NC NO auxiliary closing O 1 contact opening O 1 NC auxiliary contact ON OFF ON O I I OFF O 175-200 Amps Catalog Auxiliary Contact 0° 30° 60° 90° Numbers Contact Configuration Main contact BDNF175A & BDAUX12 1 NO & 1 NC BDNF200A BDAUX13 2 NO & 2 NC NO auxiliary closing O 1 contact opening O 1 NC auxiliary contact OFF ON O I 26 ¤ Disconnect Switches Bussmann Technical Data — Auxiliary Contact Timing Diagrams Non-Fusible — 400-3150 Amps 400-600 Amps 0° 30° 60° 90° Catalog Auxiliary Contact Numbers Contact Configuration Main contact BDNF400 & BDAUX1 1 NO & 1 NC BDNF600A BDAUX2 2 NO & 2 NC NO auxiliary closing O 1 contact opening O 1 NC auxiliary contact OFF ON ON O I I OFF O 800-3150 Amps 0° 30° 60° 90° Catalog Auxiliary Contact Numbers Contact Configuration Main contact BDNF800A through BDAUX1 1 NO & 1 NC closing O 1 NO auxiliary BDNF3150 BDAUX2 2 NO & 2 NC contact opening O 1 NC auxiliary contact OFF ON O I 27 ¤ Disconnect Switches Bussmann Approximate Dimensions — Fusible 00.00 Inches 00.00 Inches 30 Amps 00.00 Millimeters 00.00 Millimeters 3.84 97.5 2.75 4.10 70.0 1.27 0.93 104.0 32.5 23.6 0.17 4.3 35mm DIN RAIL 3.66 2.44 93.0 62.0 2.95..3.15 75.0...80.0 3.70 94.0 1.83 46.5 1.52 3.66 38.5 93.0 4.15 105.5 2.00 51.0 60 Amps 0.23 0.27 Dia. 5.9 7.1 4.74 2.36 2.92 120.4 3.70 60.0 74.1 94.0 1.18 30.0 3.19 81.0 1.46 .80 1.54 4.85 37.0 20.3 39.1 123.1 5.57 141.4 6.85 ( 3 POLE ) 8.31 ( 4 POLE ) 5.50 ... 8.63 2.00 140.0 ... 219.0 174.0 50.8 211.0 100 Amps 1.75 2.13 0.26 Dia. 44.4 54.1 6.6 M6 x 1.0 0.23 5.9 0.27 Dia. 6.9 4.76 121.0 1.18 3.58 6.80 30.0 91.0 172.5 5.61 2.36 142.5 60.0 3.90 99.2 2.15 1.14 54.6 .79 5.15 29.0 20.0 7.70 130.8 195.5 2.01 5.50...8.62 8.39 51.0 139.7....219.0 213.0 8.78 223.0 28 ¤ Disconnect Switches Bussmann Approximate Dimensions — Fusible 00.00 Inches 200 Amps 00.00 Millimeters 2.02 51.3 0.27 Dia. 0.47 6.8 11.9 1.84 8.88 5.91 46.7 225.5 150.1 5.91 150.1 9.87 4.38 250.7 111.2 7.86 6.89 199.6 5.71 175.0 145.0 2.25 0.95 1.81 0.20 1.51 57.1 24.1 0.28 45.9 7.24 5.0 38.3 7.1 1.90 7.84 183.9 48.2 199.1 2.40 9.25 ... 13.58 60.9 234.9 ... 344.9 7.80 (2 Pole) 10.25 (3 Pole) 12.68 (4 Pole) 260.3 322.0 198.1 400 Amps 1.97 50.0 0.47 0.27 Dia. 11.9 6.8 12.18 1.84 309.3 8.62 46.7 218.9 5.25 133.3 5.91 150.1 8.89 225.8 10.82 7.67 5.71 274.8 194.8 145.0 2.73 1.38 0.28 69.3 1.77 1.97 8.79 35.0 0.20 7.1 2.40 44.9 50.0 223.2 7.80 5.0 70.0 198.1 9.25 ... 13.58 8.43 (2 Pole) 11.19 (3 Pole) 13.94 (4 Pole) 234.9 ... 344.9 214.1 284.2 354.0 600 & 800 Amps 1.83 0.35 Dia. 46.4 8.8 0.47 11.9 10.12 14.30 7.48 3.74 257.0 363.2 189.9 95.0 5.97 11.11 151.9 9.84 282.1 249.9 12.97 5.71 329.4 145.0 0.23 1.59 1.58 0.92 2.57 3.55 5.8 8.71 40.3 40.1 23.3 65.2 90.1 12.14 221.2 0.95 2.43 10.23 ... 13.78 308.0 54.1 60.9 259.8 ... 350.0 11.14 (2 Pole) 14.69 (3 Pole) 18.23 (4 Pole) 282.9 373.1 463.0 29 ¤ Disconnect Switches Bussmann Approximate Dimensions — Non-Fusible, Toggle Type 00.00 Inches 80 Amps 00.00 Millimeters 1.49 0.14 37.8 3.6 1.61 2.98 40.9 75.6 1.49 37.8 1.55 1.77 39.4 45.0 2.11 1.87 53.6 47.5 2.48 63.0 100 Amps 1.96 3.15 50.0 80.0 1.81 46.0 0.59 0.25 15.0 6.35 5.79 0.15 147.0 3.81 3.03 1.68 77.0 1.96 42.6 50.0 1.18 0.81 0.10 30.0 20.5 2.5 2.75 2.34 70.0 59.4 3.06 3.06 78.0 78.0 30 ¤ Disconnect Switches Bussmann Approximate Dimensions — Compact, Non-Fusible 00.00 Inches Non-Fusible, 16-40A, 600V 00.00 Millimeters Base and DIN rail mounted switches CDNF16, CDNF25, & CDNF32 .4 1.8 0.4 0.4 11 45 11 11 0.6 15 I ON 2.4 2.1 60 1.4 O 1.5 1.4 54 35 37 35 1.6 2.7 40 68 .5 13 5 0.9 22 ş.18 4.5 1.4 35 0.4 0.5 0.4 11 13 11 CDNF45 0.7 0.7 17.5 0.4 2.4 17.5 11 61.0 0.6 1.8 15 45 0.5 13 I ON 2.8 3.2 O 1.5 1.4 72 2.1 37 82.5 OFF 35 54 3.6 91.5 5 1.7 43.5 ş.18 0.4 4.5 2.1 0.4 11 11 52.5 0.7 17 Door mounted switches CDNF16D, CDNF25D, & CDNF32D 1.69 43 1.42 36 1.69 1.42 2.13 43 36 54 .13 ş 3.2 .43 2.68 11 68 .22 1.06 5.7 27 .21 5.4 1 1.97( 50) 1.46 1.57 2 2.56 (65) 37 40 .12 .87 3 1 22 .98 (25) 2 .43 .53 .43 1.36 (34.5) 1.38 11 11 13.4 35 1 CDH7S + CDH8S 2 CDH9S + CDH10S 31 ¤ Disconnect Switches Bussmann Approximate Dimensions — Non-Fusible 00.00 Inches L 2.02 80 Amps 51.3 00.00 Millimeters 0.20 5.08 Auxiliary Switches 0.16 4.0 1.66 42.1 2.75 3.31 69.8 84.0 1.66 42.1 3.15 1.69 80.0 1.97 42.9 2.29 50.0 58.1 2.92 2.08 74.1 52.8 2.92 (2no + 2nc) 74.1 3.55 3.34 (4no + 4nc) 90.1 84.8 1.99 50.5 H 100 Amps 1.89 3.55 48.0 L 90.1 1.81 0.25 Auxiliary Switches 45.9 0.59 0.20 6.3 14.9 5.0 HANDLE TYPE DIMENSION PISTOL SELECTOR 3.03 0.16 76.9 5.91 3.55 4.0 L 1.69 150.1 90.1 3.88 1.97 42.9 6.88 - 7.50 5.50 - 6.12 98.5 H 2.75 50.0 174.8 - 190.5 139.7 - 155.4 69.8 3.15 80.0 0.10 0.81 1.18 2.5 20.5 2.75 29.9 2.42 69.8 61.9 3.06 3.12 (2no + 2nc) 77.7 79.2 4.33 (4 Pole) 3.54 (4no + 4nc) 109.9 1.99 (2no + 2nc) 89.9 3.54 50.5 H 89.9 (4no + 4nc) 175 Amps 1.81 1.81 4.55 45.9 45.9 115.5 0.35 1.42 8.8 36.0 0.27 0.27 6.8 6.8 0.31 7.8 1.41 35.8 4.32 8.36 4.33 109.7 212.3 109.9 7.45 5.37 6.35 136.4 186.4 3.15 161.2 80.0 0.16 1.26 0.43 4.0 0.98 32.0 3.67 10.9 24.8 6.21 93.2 157.7 4.56...8.50 1.99 6.02 (2 Pole) 7.86 (3 Pole) 9.65 (4 Pole) 50.5 115.8...215.9 152.9 199.6 245.1 32 ¤ Disconnect Switches Bussmann Approximate Dimensions — Non-Fusible 00.00 Inches 200 Amps 00.00 Millimeters 2.21 2.21 4.55 56.1 56.1 115.5 0.35 1.42 8.8 36.07 0.27 0.27 6.8 0.31 6.8 7.87 1.41 35.8 4.32 4.33 8.36 109.9 212.34 109.7 6.35 5.37 3.15 161.2 7.34 136.4 80.0 186.44 0.16 1.26 0.43 0.98 4.06 32.0 10.9 3.67 24.8 7.00 93.2 177.8 1.99 4.56...8.50 6.42 (2 Pole) 8.64 (3 Pole) 10.82 (4 Pole) 50.5 115.8 ... 215.9 163.0 219.4 274.8 400 Amps 1.97 50.0 0.62 0.27 Dia. 15.7 0.47 6.8 11.9 1.84 46.7 11.82 5.52 300.2 140.2 5.91 150.1 8.55 7.31 5.71 217.1 185.6 145.0 10.48 266.1 0.70 17.7 0.28 2.74 0.20 1.77 7.1 1.58 7.88 69.6 1.14 5.08 44.96 40.1 5.12 200.9 28.9 1.95 130.05 50.0 7.48 (2 Pole) 10.25 (3 Pole) 12.99 (4 Pole) 2.40 7.88 ... 12.19 189.9 260.3 325.9 60.9 200.1 ... 309.6 600 Amps 1.97 0.62 50.0 15.7 0.47 0.27 Dia. 11.9 6.8 1.84 11.77 46.7 298.9 5.91 5.52 150.1 140.2 10.42 264.6 8.55 7.31 217.1 185.6 5.71 145.0 0.28 7.1 0.70 17.7 1.97 3.56 0.20 1.58 1.77 50.0 90.4 1.14 40.1 5.0 44.9 5.12 28.9 9.56 130.0 242.8 8.39 (2 Pole) 11.90 (3 Pole) 15.47 (4 Pole) 2.40 7.88 ... 12.19 60.9 200.1 .. 309.6 213.1 302.2 392.9 33 ¤ Disconnect Switches Bussmann Approximate Dimensions — Non-Fusible 00.00 Inches 800 Amps 00.00 Millimeters 2.04 0.59 51.8 14.9 0.35 Dia. 8.8 0.47 11.9 19.10 3.74 485.1 95.0 7.48 8.27 189.9 210.0 10.00 254.0 14.65 372.1 5.71 145.0 1.55 39.3 0.47 1.57 0.96 2.32 3.54 1.97 11.9 39.8 50.0 24.3 58.9 89.9 4.92 11.73 0.35 124.9 297.9 8.8 2.40 10.04 ... 12.80 10.75 (2 Pole) 14.29 (3 Pole) 17.83 (4 Pole) 60.9 255.0 ... 325.1 273.0 362.2 452.8 1200 Amps 1.91 0.59 48.5 14.9 0.35 Dia. 8.8 19.09 0.47 484.8 11.9 3.74 95.0 8.27 210.0 7.48 17.71 189.9 449.8 10.00 14.65 372.1 254.0 15.19 5.71 385.8 145.0 1.55 39.3 0.96 2.31 3.55 1.25 0.66 24.3 58.9 89.9 16.7 31.7 11.73 0.48 4.92 297.9 12.1 124.9 10.75 (2 Pole) 14.29 (3 Pole) 17.83 (4 Pole) 2.40 10.04 ... 12.80 60.9 255.0 ... 325.1 273.0 362.9 452.8 1600, 2000, 3150 Amps 10.67 271.0 6.57 3.94 0.69 166.8 17.5 100.0 1.28 32.5 3.43 3.43 87.1 87.1 1.75 1.38 44.4 35.0 0.35 Dia. 25.02 8.8 635.5 0.47 11.9 3.74 7.48 95.0 23.95 189.9 8.35 21.50 600.3 212.0 546.1 21.44 14.65 544.5 372.1 8.66 219.9 1.00 25.4 4.44 2.45 5.47 0.59 0.92 14.9 112.7 23.3 62.2 138.9 15.84 0.48 402.3 12.1 3.94 13.38 ... 21.06 12.95 (2 Pole) 18.43 (3 Pole) 23.90 (4 Pole) 100.0 339.8 ... 534.9 328.9 468.1 607.0 34 ¤ Disconnect Switches Bussmann Approximate Dimensions — Handles 00.00 Inches Handles 00.00 Millimeters for base & DIN rail mounted switches CDH1S & CDH2S 0.6 1 15 25.4 BDH47 & BDH99 0.3 1.9 0.1 6.5 48 2.54 I ON 2.7 68 1 1.2 1.6 25.4 30.5 Ş 40.6 3.2 81 2.0 0.9 50.8 22.8 CDH3S, CDH4S, CDH5S & CDH6S 0.6 1 15 25.4 0.3 1.9 0.1 6.5 48 BDH100, BDH102, BDH103, & 2.54 BDH104 I ON 1 1.2 25.4 1.6 2.7 30.5 Ş 40.6 68 2.4 61 0.9 22.8 2.0 Handles 50.8 for door mounted switches CDH7S & CDH8S 1 1 25.4 25.4 0.3 1.9 0.1 6.5 48 2.54 Mounting dimensions, I ON pistol handle 1 1.2 1.6 25.4 30.5 Ş40 40.6 0.3 O 7 0.9 22.8 CDH9S & CDH10S 1.3 2.6 1 66 33 0.1 25.4 2.54 0.39 45° 1.8 10 45 2.2 I ON 56 1 25.4 1.6 1.6 40.6 Ş 40.6 0.9 22.8 35 O OFF O OFF O OFF O OFF ¤ Disconnect Switches Bussmann Approximate Dimensions — Transfer & Bypass Switches Transfer & bypass switches 00.00 Inches CDZW8 00.00 Millimeters CDZW6 2.84 72.0 1.54 B 2.16 4.57 39.0 55.0 116.0 0.20 1.77 DIA 5.00 45.0 .71 18.0 1.53 11.02 39.0 280.0 1.18 min. + 30.0 Max. 13 steps of 0.59 0.59 15.0 15.0 A 3.15 80.0 0.20 5.0 0.24 6.0 0.59 15.0 A = 3.54 + 10 steps of 0.59 steps 90.0 15.0 B = 0.32 min.; 2.55 max. 8.0 65.0 CDZW17 2.84 72.0 1.54 2.16 1.18 39.0 55.0 30.0 1.77 DIA .71 45.0 18.0 1.53 39.0 B 11.02 280.0 0.20 Max. 5.0 3.15 80.0 0.24 A 6.0 0.59 15.0 0.32 ... 2.55 8.0 ... 65.0 0.20 5.0 A = 4.72 + 8 steps of 0.59 120.0 15.0 B = 3.54 + 6 steps of 0.59 15.0 90.0 36 ¤ Disconnect Switches Bussmann Approximate Dimensions — Transfer Switches 00.00 Inches 00.00 Millimeters BDZW1 BDZW2 0.47 12.00 2.84 1.57 72.0 40.0 2.16 4.57 1.54 B 39.0 55.0 116.0 1.77 DIA 45.0 7.72 0.71 196.0 18.0 0.24 0.24 6.00 6.00 1.53 4.72 39.0 120.0 A 3.15 11.02 80.0 280.0 Max. 0.24 6.0 0.24 6.0 45.0 0.59 0.59 15.0 15.0 1.77 min. + 13 steps of 0.59 A = 3.54 + 10 steps of 0.59 steps 15.0 90.0 15.0 B = 0.32 min.; 2.55 max. 8.0 65.0 BDZW3 — ZW14 and — ZW15 BDZW4 9.50 241.3 8.74 222.0 4.13 105.0 4.60 116.8 B A Dimensions in Inches & mm A B BDZW3 11.81 0.47 300.0 12.0 BDZW14 9.84 0.47 250.0 12.0 BDZW15 19.69 0.47 500.0 12.0 4.63 117.5 BDZW19 11.02 0.31 280.0 8.0 0.55 14.0 37 ¤ Disconnect Switches Bussmann Approximate Dimensions — Transfer Switches 00.00 Inches 00.00 Millimeters BDZW5 BDZW9 and CDZW9 9.50 241.3 8.74 222.0 4.60 0.47 116.8 12.00 4.13 105.0 0.79 15.0 2.36 min. + 19 steps of 0.79 20.0 60.0 4.63 117.5 0.55 14.0 38 ¤ Disconnect Switches Bussmann Approximate Dimensions — Transfer Switches 00.00 Inches BDZW11 BDZW12 00.00 Millimeters 3.27 2.28 4.84 4.84 3.54 83.0 90.0 123.0 58.0 123.0 2.08 1.35 53.0 1.57 34.0 40.0 1.30 1.30 33.0 33.0 0.47 0.47 12.0 12.0 3.31 84.0 3.31 0.47 B 84.0 12.0 27.17 690.0 Max. 5.71 145.0 A 20.08 A 8.66 510.0 0.79 20.0 220.0 Max. 0.79 20.0 0.31 ... 0.59 8.0...15.0 0.31 ... 0.59 8.0 ...15.0 B 0.47 12.0 B = BDZW11 = 0.47 A = 8.27 + 11 steps of 0.79 12.0 210.0 20.0 BDZW20 = 0.31 A = 8.27 + 18 steps of 0.79 8.0 210.0 20.0 BDZW13 2.28 3.54 4.4 90.0 58.0 123.0 1.57 40.0 1.30 33.0 0.47 12.0 3.31 84.0 0.47 12.0 A 8.66 220.0 0.79 20.0 27.17 690.0 1.42 ... 1.69 Max. 36.0 ... 43.0 B 0.47 12.0 0.47 12.0 A = 8.27 + 18 steps of 0.79 210.0 20.0 B = 9.84 + 18 steps of 0.79 250.0 20.0 39 ¤ Disconnect Switches Bussmann Approximate Dimensions — Transfer Switches 00.00 Inches 00.00 Millimeters BDZW18 BDZW20 3.27 0.47 4.84 12.00 83.0 123.0 2.08 1.57 1.35 53.0 40.0 34.0 1.30 33.0 6.93 0.47 176.0 12.0 0.24 0.24 8.00 8.00 3.31 84.0 B 3.94 100.0 20.08 510.0 Max. 5.71 145.0 A 0.79 20.0 3.15 0.31 ... 0.59 80.0 8.0 ...15.0 0.59 15.0 3.15 min. + 10 steps of 0.79 15.0 B BDZW21 3.27 4.84 83.0 123.0 1.35 2.08 35.0 53.0 A = 8.27 + 11 steps of 0.79 B = BDZW11 = 0.47 12.0 210.0 20.0 1.30 BDZW20 = 0.31 33.0 0.47 8.0 12.0 3.31 84.0 0.31 8.0 B 5.71 145.0 0.79 0.31 20.0 8.0 A 0.31 ... 0.59 20.0 7.0 ... 43.0 510.0 Max. 0.31 8.0 A = 9.84 + 9 steps of 0.79 250.0 20.0 B = 8.27 + 9 steps of 0.79 210.0 20.0 40 Headquarters Bussmann Denmark Cooper Industries 5 Literbuen Bussmann Division DK-2740 Skovlunde P.O. Box 14460 Copenhagen, Denmark St. Louis, Missouri 63178-4460, USA Telephone: 45 4485 0900 Telephone: 314 394 2877 Facsimile: 45 4485 0901 Facsimile: 800 544 2570 Bussmann France Bussmann Circuit Components Tour Mattei 7300 West Wilson Avenue 207 Rue de Bercy Chicago, IL 60656-4793, USA 75587 Paris Cedex 12 Telephone: 708 867 4600 France Facsimile: 708 867 2211 Telephone: 33 1 4475 0033 Facsimile: 33 1 4475 0420 European Headquarters Bussmann Division Bussmann Germany Cooper (U.K.) Limited Frankfurter Landstrasse 19 Burton-on-the-Wolds 64546 Mörfelden Leicestershire LE12 5th, England Germany Telephone: 44 1509 882737 Telephone: 49 6105 951509 Facsimile: 44 1509 882786 Facsimile: 49 6105 951510 Bussmann Asia Pacific Bussmann India 331 North Bridge Road 2nd Floor, Unit #5 #03-02 Odeon Towers White House Singapore 188720 23-29, St. Marks Road Republic of Singapore Bangalore – 560-001 Telephone: 65 336 3610 India Facsimile: 65 336 4810 Telephone: 91 80 227 0893 Facsimile: 91 80 224 0124 Bussmann Australia Dock 5, Block X Bussmann Mexico 391 Park Road Arrow-Hart S.A. de C.V. P.O. Box 257 Poniente 148, No. 933 Regents Park, Sydney 02300 Mexico, D.F. Mexico NSW 2143, Australia Telephone: 52 5 587 0211 Telephone: 61 2 9743 8333 Facsimile: 52 5 567 4049 Facsimile: 61 2 9743 8070 Bussmann Brasil Bussmann do Brasil Ltda. Rodovia Santos Dumont, Km 23 Cruz das Almas Itu-Sao Paulo 13 300-000 Brasil Telephone: 55 11 7824 1856 Facsimile: 55 11 7824 1721 © Cooper Industries, Bussmann Division, Printed in U.S.A. Form No. BDS.1197

Frequently asked questions

What makes Elite.Parts unique?

chervon down
At GID Industrial (Elite.Parts' parent company), we specialize in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

What kind of warranty will the BDH47 have?

chervon down
Warranties differ by part and by which suppliers we use to procure it for you. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carriers does Elite.Parts work with?

chervon down
Elite.Parts can ship via FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Will Elite.Parts sell to me even though I live outside the USA?

chervon down
Absolutely! We are happy to serve customers regardless of location. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

I have a preferred payment method. Will Elite.Parts accept it?

chervon down
All major credit cards are accepted: Visa, MasterCard, Discover, and American Express. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

FUSE CLIP TINNED ANGLED LEADS

product

FUSE CLIP SILVER STRAIGHT LEADS

product

FUSE 3/4A 250V FAST ABC CERM

product

FUSE 1/4A 250V FAST CERM AXIAL

product

FUSE 15A 250V FAST CERM AXIAL

product

FUSE 1A 250V FAST CERM AXIAL