CLIFTON EWPC905T
Datasheet
Extracted Text
EWPC 905 rel. 12/96 ing controllers with dual output GENERAL DESCRIPTION Led “I”: status light of output 1. The EWPC 905 (/T, /R, /P) is a series of mi- Led “II”: status light of output 2. croprocessor based and fully programma- PARAMETER PROGRAMMING ble process controllers for dual setpoint or WHAT IT IS Neutral Zone applications. Programming is easily accessed by hold- The EWPC 905 is a series of micro- In the Neutral Zone control mode it pro- ing the “SET” button down for more than 4 processor based and fully program- vides two relay outputs which are located seconds; the first parameter is displayed mable process controllers for dual at equal values above and below the set- while the status light Led “I” remains blink- setpoint or Neutral Zone applica- point selected. This value - the Neutral ing during the programming period. tions. Zone - is field adjustable. Other parameters are accessed with the Three different versions of this con- The front keypad of these controllers offers “UP” and “DOWN” button. With the “SET” troller are available: EWPC 905/T several alpha-numeric menu prompts to button, the actual setting of each parame- for Temperature, EWPC 905/R for configure the controller for each specific ter is displayed. To change a parameter Relative humidity and EWPC 905/P application (see further). setting, push the “SET” plus the “UP” (or for Pressure control. Three different versions of this controller “DOWN”). are available: EWPC 905/T for The system will automatically return to its Temperature, EWPC 905/R for Relative normal operating mode a few seconds af- humidity and EWPC 905/P for Pressure ter the programming procedure is com- HOW IT IS MADE control. The EWPC 905 (/T, /R, /P) is sup- pleted or interrupted. • Dimensions: front 74x32 mm plied in the popular “32x74” ELIWELL. (2.913x1.260"), depth 67 mm DESCRIPTION OF PARAMETERS FRONT KEYPAD (2.637") The following list of parameters is com- • Mounting: flush panel mount with SET (dual setpoint control mode): pushed plete. According to the selected control mounting bracket once the setpoint 1 value will be displayed mode (ON-OFF or Neutral Zone, see para- • Protection: the instrument front- for 5 seconds (Led “SET 1” is on). Pushed meter “Ft”), only the applicable parameters panel is waterproof IP65; an op- once again within 5 seconds the setpoint 2 will be shown and accessed. tional snap-on cover can be value will be displayed (Led “SET 2” is on). d1: differential setpoint 1. supplied to provide additional pro- The setpoint can be changed with the The switching differential (hysteresis) set- tection of the rear terminal block “UP” or “DOWN” button. point 1 can be set with positive value • Connections: screw terminal SET (Neutral Zone control mode): push (make on rise) or with negative value (make 2 block (2.5 mm ; one wire each ter- and release to display the setpoint for 5 on fall). minal only, in compliance with seconds. During this period, the Led “SET See parameters “HC1” and “HC2”. VDE norms) 1” is on and the setpoint can be changed d2: differential setpoint 2. • Display: 12.5 mm LED (0.50") with the “UP” or “DOWN” button only. Same as “d1”. • Push buttons: located on front UP: used to increase the setpoint value, as db: dead band (or Neutral Zone). panel well as the parameter when in program- This is the span above and below the set- • Outputs: two (2) SPST relays 8(3)A ming. When held down for a few seconds, point beyond which relay 1, respectively 250V AC the change rate accelerates. relay 2 are energized; once an output is • Auxiliary output: 12 Vdc/60 mA DOWN: same functions except to de- energized, the output remains ON until (for transducer power supply, e.g. crease a value. setpoint is reached. humidity sensor, pressure trans- Led “SET 1”: status light of Setpoint 1. On LS1: Lower Set 1. ducer, etc.) during display/change Setpoint 1 or blink- This is the lower limit below which the user • Inputs (depending on model): ing during programming. cannot change the setpoint 1; normally set PTC / RTD (Ni100, Pt100) / Led “SET 2”: status light of Setpoint 2. On at the lowest value recommended for the TC (J, K) / 4…20 mA (Ri = 41 Ω) for during display/change Setpoint 2. sensor. EWPC 905/T; EWHS 28/31 for EWPC 905/R and EWPA 007/030 for EWPC 905/P • Resolution: 1 °C (°F) or 0,1 °C (°F) • The right-most digit can also be set to read-out in 0 or 5 only, or in all 10 digits • Accuracy: better than 0,5% of full scale • Power supply (depending on mod- el): 12 Vac/dc or 24 Vac/dc DEFAULT SETTINGS - STANDARD MODELS in = reverse = light OFF when output 1 is energized. Parameter Description ON - OFF Dead Band Unit LF2: Led Function 2. d1 differential set 1 1 (C) / –1 (H) / °C / °F Same as “LF1”. dP: decimal Point. d2 differential set 2 1 (C) / –1 (H) / °C / °F Choose whether the resolution is required db dead band / 1 °C / °F with or without decimal point. LS1 Low Set 1 min min °C / °F oF = without decimal point; LS2 on = with decimal point. Low Set 2 min min °C / °F NOTES: (a) the decimal point of models HS1 High Set 1 max max °C / °F with current or voltage input is shifted: the HS2 High Set 2 max max °C / °F actual value of parameters “Lci” and “Hci” od output delay 0 0 seconds must be multiplied by 10; (b) on all ver- sions, if a unit is changed from without Lci Low current input 20 (%R.H.) 20 (%R.H.) various decimal point to with decimal point, all pa- Hci High current input 100 (%R.H.) 100 (%R.H.) various rameter values expressed in degrees will CAL CALibration 0 0 °C / °F automatically be divided by 10, including Ft Function type on nr flag the setpoint !! (c) the decimal point selec- tion is not available on models for thermo- PSE Probe SElection Ni / Pt / Fe / Cr Ni / Pt / Fe / Cr flag couple input. OCO Output COnnection in in flag hdd: half digit display. HC1 Heating / Cooling output 1 H / C / flag The right-most digit can be set to read-out in 0 or 5 only, or in all 10 digits. HC2 Heating / Cooling output 2 H / C / flag hdd = n: e.g. 070, 071, 072 etc. (if without rP1 relay Protection 1 ro ro flag decimal point) or 70.0, 70.1, 70.2 etc. (if rP2 relay Protection 2 ro ro flag with decimal point); hdd = y: e.g. 070, 075, 080, etc. (if without LF1 Led Function 1 di di flag decimal point) or 70.0, 70.5, 80.0, etc. (if LF2 Led Function 2 di di flag with decimal point). dP decimal Point on / oF oF flag Useful when measuring values varying hdd half digit display n n flag rapidly (e.g. %R.H.). tAb: tAble of parameters. tAb tAble of parameters / / flag This shows the configuration of the para- meters as set in the factory; can not be modified (for factory identification and di- LS2: Lower Set 2. on = ON-OFF; nr = neutral zone. agnostic purposes only). This is the lower limit below which the user PSE: Probe SElection. cannot change the setpoint 2; normally set Input type (for RTD or Thermocouples NEUTRAL ZONE (DEAD BAND) at the lowest value recommended for the only). The Neutral Zone (Dead Band) control is sensor. RTD models: Ni = Ni100; Pt = Pt100. obtained by setting to “nr” the parameter HS1: Higher Set 1. T/C models: FE = TcJ; Cr = TcK. “Ft”. Similar to LS1, however setting an upper OCO: Output COnnection. This band width is always such that the limit for the setpoint 1. Setpoint dependency. setpoint is at midpoint. Both output relays HS2: Higher Set 2. di = setpoint 2 dependent on set 1 (for 2- are OFF as long as the temperature re- Similar to LS2, however setting an upper stage control; mains within these two limits. limit for the setpoint 2. in = setpoint 2 independent from set 1. The total value of the dead band is twice od: output delay. HC1: Heating/Cooling output 1. the value set with parameter “db”. This provides a delay selection for the out- Relay switch function output 1. As soon as the process temperature ex- puts in applications where noise may H = heating (humidification; reverse ac- ceeds the upper band limit or falls below cause brief erroneous signals from the tion); the lower band limit, the corresponding sensor to the controller. C = cooling (dehumidification; direct ac- output relay will be energized and stay on Factory set at “0”. tion). until the temperature comes back to the Lci: Lower current input. HC2: Heating/Cooling output . setpoint. For EWPC 905/R, EWPC 905/P and Relay switch function output 2. EWPC 905/T with current input only. H = heating (humidification; reverse ac- INSTALLATION Read-out corresponding to 4 mA input sig- tion); The instrument is designed for flush panel nal (factory set at 20 %R.H for EWPC C = cooling (dehumidification; direct ac- mount. Prepare a 29x71 mm panel cut- 905/R). tion). out; insert the instrument through the front Hci: Higher current input. rP1: relay Protection 1. and fasten with the U-bracket supplied For EWPC 905/R, EWPC 905/P and Determines the status of the relay in case with the unit. EWPC 905/T with current input only. of sensor defect. The ambient temperature around the in- Read-out corresponding to 20 mA input Factory set at “ro”. strument should be kept between –5 and signal (factory set at 100 %R.H for EWPC ro = relay open; rc = relay closed 65 °C (23…149 °F). 905/R). rP2: relay Protection 2. Select a location which will not be subject CAL: CALibration. Same as “rP1”. to high humidity or condensation and allow This offers an adjustment up or down of LF1: Led Function 1. some ventilation to provide cooling to the the read-out, if needed. Determines whether the status light “I” is instrument. Factory set at “0”. ON or OFF in relation to output 1. ELECTRICAL WIRING Ft: Function type. di = direct = light ON when output 1 is en- Control mode selection (output 1). ergized; The instrument is equipped with an internal EWPC 905 12/96 ing 2 CONNECTIONS Connections: screw terminal block 2 (2.5mm ; one wire each terminal only, in compliance with VDE norms). 8 9 10 8 9 10 8 9 10 Display: 12.5 mm LED (0.50"). EWPC 905/T Push buttons: located on front panel. Data storage: non-volatile EEPROM PTC Pt100 / Ni100 Pt100 / Ni100 memory. 3 wires 2 wires Operating temperature: –5…65 °C; 1 2 3 4 6 7 8 9 10 (23…149 °F). 8 9 10 8 9 10 8 9 10 Storage temperature: –30…75 °C; (–22…167 °F). + – load 1 load 2 Outputs: two (2) SPST relays 8(3) 250V TcJ / TcK EWHS 31 4…20 mA input AC. Auxiliary output: 12 Vdc/60 mA (for POWER SUPPLY transducer power supply, e.g. humidity sensor, pressure transducer, etc.). Inputs (depending on model): PTC / RTD (Ni100, Pt100) / TC (J, K) / 4…20 mA 8 9 10 8 9 10 EWPC 905/R (Ri = 41 Ω) for EWPC 905/T; EWHS 28/31 for EWPC 905/R and EWPA 007/030 for EWPC 905/P. EWHS 28 EWHS 31 Resolution: 1 °C (°F) or 0,1 °C (°F). The right-most digit can also be set to read-out 1 2 3 4 6 7 8 9 10 8 9 10 in 0 or 5 only, or in all 10 digits. Accuracy: better than 0.5% of full scale. Power supply (dep. on model): 12 Vac/dc load 1 load 2 4…20 mA input ±15% or 24 Vac/dc ±15%. POWER SUPPLY Eliwell S.p.A. via dell’Artigianato, 65 Zona Industriale 8 9 10 EWPC 905/P 32010 Pieve d’Alpago (BL) Italy EWPA 007 Telephone +39 (0)437 986111 EWPA 030 Facsimile +39 (0)437 989066 1 2 3 4 6 7 8 9 10 8 9 10 A Siebe Group Company load 1 load 2 4…20 mA input POWER SUPPLY ERROR ANNOUNCIATION screw terminal block suitable for max. 2 2.5 mm wiring (one wire each terminal Any sensor input defect will be displayed only, in compliance with VDE norms). as follows: “- - -” in case of shorted sensor; Make sure that the power supply corre- “EEE” in case of sensor break, or sensor sponds with the rating shown on the in- absence. The “EEE” error message also strument, i.e. 12 Vac/dc (EWPC 905/T and appears in the event of ovverrange or un- EWPC 905/R in this version are recognized derrange of the system temperature. according to VDE and UL) or 24 Vac/dc. It is recommended to doublecheck the Refer to the instrument label for the applic- sensor wiring before diagnosing a probe able terminals to be used for the sensor as defective. cable. If an ELIWELL humidity or pressure TECHNICAL DATA sensor is used (EWPC 905/R or EWPC 905/P) keep in mind that it can be pow- Housing: black ABS plastic, autoestin- ered by the controller (see wiring diagram). guish. Separate the wiring of the input signals Dimensions: front 74x32 mm from those of the power supply and (2.913x1.260"), depth 67 mm (2.637"). switched output wiring. Mounting: flush panel mount with mount- The relay output contacts are voltage free ing bracket. and independent; do not exceed the resis- Protection: the instrument frontpanel is tive rating of 8 Amp at 250 Vac. For larger waterproof IP65; an optional snap-on cov- loads, please use an external contactor or er can be supplied to provide additional relay. protection of the rear terminal block. 3 EWPC 905 12/96 ing gnd gnd input white input brown brown 12 Vdc out 12 Vdc out blue white white brown blue red gnd input 12 Vdc out
Frequently asked questions
What makes Elite.Parts unique?

What kind of warranty will the EWPC905T have?

Which carriers does Elite.Parts work with?

Will Elite.Parts sell to me even though I live outside the USA?

I have a preferred payment method. Will Elite.Parts accept it?

What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods