CHEROKEE INTERNATIONAL CAP200D3
Specifications
Dimensions
8.50” x 4.95” x 1.5”
Efficiency
70% typical (measured at full load)
EMI
FCC and VDE Level “B” (Conducted)
Hold-Up Time
20ms at full load, low line for V1, V2 and V3. 3ms on V4
Input Current
3.3A max. (at 90VAC)
Input Protection
Single fuse (6.3A, 250VAC / HB Type)
Input Voltage Range
85-264VAC; 47-63Hz (Continuous range operation)
Inrush Current
(Cold Start) 35A @ 115VAC, 70A @ 230VAC typical
Maximum Output Power
200 Watts Continuous
Operating Temperature
0~50ºC. Derates linearly from 50ºC to 70ºC at 2.5% per ºC, 200 LFM Required for Full Power
Output Ripple & Noise
1% or 50mV (whichever is greater) pk-pk maximum @ 20MHz
Over Current Limit
110 - 135% of max Iout. Output recovers when the fault is removed
Over Voltage Protection
Trip point set at 120% - 130% of V1 or V2. To reset, cycle input power
Regulation
+/- 2% max of V1 / V2 / V3, V4 is +/-4%
Shock & Vivratio
n Per MIL STD-810E per 516.4 Part IV
Status & Control Signals
Remote Sense (Compensates 5% of V1 & V2 only), Remote on/off (TTL Low or Short - Off, Open Collector), Input Power Fail (TTL High for normal operation, goes low >4ms before loss of regulation), DC Good Signal (TTL High for normal operation, Open Collector)
Total Power Over-Load Limit
Set at 240W typical by sensing the primary input current
Transient Response
Peak deviation of ± 3% with a 25% step load change at 3A/µs slew rate
Voltage Adjustment Range
+/-5% of V1 / V2 / V3 only, V4 is fixed
Datasheet
Extracted Text
C CA AP P2 20 00 0 S Se er ri ie es s 200 Watt Low Profile Switching Power Supply with 1-4 Outputs P Pr ro od du uc ctt F Fe ea attu ur re es s:: S Siin ng glle e & & M Mu ullttiip plle e O Ou uttp pu utt M Mo od de ells s � A Au utto o R Ra an ng ge e 8 85 5- -2 26 64 4 V VA AC C IIn np pu utt � 1 1U U H Hiig gh h P Pr ro offiille e � N No o M Miin niim mu um m L Lo oa ad d R Re eq qu uiir re em me en ntts s � M Me ee etts s V VD DE E/ /F FC CC C C Clla as ss s “ “B B” ” E EM MII � O Ov ve er r- -V Vo olltta ag ge e,, O Ov ve er r- -C Cu ur rr re en ntt,, O Ov ve er r- -T Te em mp pe er ra attu ur re e � & & O Ov ve er r- -P Po ow we er r P Pr ro otte ec cttiio on n F Fe ea attu ur re es s F Fu ullll S Sa affe etty y C Ce er rttiiffiic ca attiio on ns s � F FE EA AT TU UR RE ES S B BE EN NE EF FIIT TS S K KE EY Y M MA AR RK KE ET T S SE EG GM ME EN NT TS S & & A AP PP PL LIIC CA AT TIIO ON NS S PFC Compliant to EN61000-3-2 Supports global use of power supply � Automation Equipment � Industrial Applications Input protection per EN61000-4 Designed to operate in harsh environmental conditions � Gaming Application � Computer Peripherals Margining on V1 & V2 Ability to compensate for system voltage drops Low Profile Reduced height to fit 1U applications � Point of Sale Equipment � Test Equipment Economical Lowered system costs � Networking / Datacom � Flexibility with options Custom capability without NRE & long lead-times S SP PE EC CIIF FIIC CA AT TIIO ON NS S C CA AP P2 20 00 0 S Se er riie es s o off 2 20 00 0 W Wa atttt L Lo ow w P Pr ro offiille e S Sw wiittc ch hiin ng g P Po ow we er r S Su up pp plliie es s Input Voltage Range 85-264VAC; 47-63Hz (Continuous range operation) Inrush Current (Cold Start) 35A @ 115VAC, 70A @ 230VAC typical Input Current 3.3A max. (at 90VAC) Input Protection Single fuse (6.3A, 250VAC / HB Type) EMI FCC and VDE Level “B” (Conducted) Efficiency 70% typical (measured at full load) Maximum Output Power 200 Watts Continuous Total Power Over-Load Limit Set at 240W typical by sensing the primary input current Voltage Adjustment Range +/-5% of V1 / V2 / V3 only, V4 is fixed Regulation +/- 2% max of V1 / V2 / V3, V4 is +/-4% Output Ripple & Noise 1% or 50mV (whichever is greater) pk-pk maximum @ 20MHz Over Voltage Protection Trip point set at 120% - 130% of V1 or V2. To reset, cycle input power Over Current Limit 110 - 135% of max Iout. Output recovers when the fault is removed Hold-Up Time 20ms at full load, low line for V1, V2 and V3. 3ms on V4 Transient Response Peak deviation of ± 3% with a 25% step load change at 3A/μs slew rate Status & Control Signals Remote Sense (Compensates 5% of V1 & V2 only), Remote on/off (TTL Low or Short = Off, Open Collector), Input Power Fail (TTL High for normal operation, goes low >4ms before loss of regulation), DC Good Signal (TTL High for normal operation, Open Collector) Operating Temperature 0~50ºC. Derates linearly from 50ºC to 70ºC at 2.5% per ºC, 200 LFM Required for Full Power Shock & Vivration Per MIL STD-810E per 516.4 Part IV Dimensions 8.50” x 4.95” x 1.5” (215.9mm x 125.7mm x 38.1mm) for standard open frame model Safety Approvals UL 1950, CSA 22.2 No. 950 & 234, TUV (EN60950), CE Mark & CB Report O Ou uttp pu utt C Co on nffiig gu ur ra attiio on ns s S Stta an nd da ar rd d O Op pttiio on ns s T Ta ab blle e M MO OD DE EL L V V1 1 O OU UT TP PU UT T V V2 2 O OU UT TP PU UT T V V3 3 O OU UT TP PU UT T V V4 4 O OU UT TP PU UT T D De es sc cr riip pttiio on n C Ca allll- -O Ou utt D Diim me en ns siio on ns s C CA AP P2 20 00 0F F1 1 12V @ 16A With vented top cover CAP200xxC 8.50 x 4.95 x 1.50” C CA AP P2 20 00 0C C2 2 3.3V @ 30A 5V @ 20A With End-Mount Fan-Cover CAP200xxG 8.55 x 4.95 x 1.95” C CA AP P2 20 00 0K K2 2 5V @ 30A 12V @ 10A With Top-Mounted Fan-Cover CAP200xxF 9.60 x 4.95 x 2.50” C CA AP P2 20 00 0A A3 3 3.3V @ 30A 2.5V @ 20A 12V @1A With IEC-320 Inlet & Switch CAP200xxL 10.50 x 4.95 x 1.55” C CA AP P2 20 00 0D D3 3 3.3V @ 30A 5V @ 20A 12V @ 8A C CA AP P2 20 00 0E E3 3 3.3V @ 30A 5V @ 20A 24V @ 4A Add 5VSB @ 200mA CAP200xxK 8.50 x 4.95 x 1.50” C CA AP P2 20 00 0H H3 3 5V @ 30A 3.3V @ 20A 12V @ 8A C CA AP P2 20 00 0D D4 4 3.3V @ 30A 5V @ 20A 12V @ 8A 12V @ 1A C CA AP P2 20 00 0H H4 4 5V @ 30A 3.3V @ 20A 12V @ 8A 12V @ 1A C CA AP P2 20 00 0K K4 4 5V @ 30A 12V @ 10A 12V @ 6A 5V @ 1A C CA AP P2 20 00 0P P4 4 5V @ 30A 12V @ 10A 24V @ 4A 12V @ 1A Specifications listed assume 25°C Ambient Operating Temperature and Full Load Operation unlesss otherwise specfified. This product is qualified for use in OEM equipment and is not appropriate for stand-alone operatiuon. The information contained within this specification is believed to be true and correct at the time of publication, however, Cherokee International accepts no responsiblity for consequences arising from printing errors or inaccuracies. The information and specifications contained herein are subject to change without notice. Cherokee International (North America) Cherokee International (Europe) Cherokee International (China) Power Supply Ltd. 2841 Dow Avenue P: (714) 544-6665 Boulevard de l’Europe, 131 P: +32.10.438.510 1353 Chenqiao Road, Shanghai Sengpu Industrial Park Tustin, CA 92780 USA F: (714) 838-4742 B-1301 Wavre, Belgium F: +32.10.438.213 Shanghai, 201401 China P: 021 6710 8910 sales@cherokeepwr.com sales.europe@cherokeepwr.com sales.china@cherokeepwr.com cherokeepwr.com C CA AP P2 20 00 0 S Se er ri ie es s 200 Watt Low Profile Switching Power Supply with 1-4 Outputs O OU UT TL LIIN NE E D DR RA AW WIIN NG G C Co on nn ne ec ctto or r IIn nffo or rm ma attiio on n J J1 1 J J9 9 J J1 10 0 B Bu us s B Ba ar rs s A AM MP P P P/ /N N 6 64 43 34 49 95 5- -2 2 M Mo olle ex x P P/ /N N 3 39 9- -0 01 1- -2 20 06 60 0 A AM MP P P P/ /N N 1 1- -6 64 40 05 56 6- -0 0 L Lo oc ca attiio on n F Fu un nc cttiio on n P Piin n F Fu un nc cttiio on n P Piin n F Fu un nc cttiio on n P Piin n F Fu un nc cttiio on n A +V2 1 Neutral 1 +V3 1 +V1 Remote Sense B Common 3 Line 2 +V3 2 -V1 Remote Sense C Common 5 Ground 3 +V4 3 V1 Margin D +V1 4 -V3 4 +V2 Remote Sense 5 -V3 5 -V2 Remote Sense 6 -V4 6 V2 Margin 7 +5VSB 8 Common 9 Inhibit 10 Power Fail Cherokee International (North America) Cherokee International (Europe) Cherokee International (China) Power Supply Ltd. 2841 Dow Avenue P: (714) 544-6665 Boulevard de l’Europe, 131 P: +32.10.438.510 1353 Chenqiao Road, Shanghai Sengpu Industrial Park Tustin, CA 92780 USA F: (714) 838-4742 B-1301 Wavre, Belgium F: +32.10.438.213 Shanghai, 201401 China P: 021 6710 8910 sales@cherokeepwr.com sales.europe@cherokeepwr.com sales.china@cherokeepwr.com cherokeepwr.com
Frequently asked questions
What makes Elite.Parts unique?

What kind of warranty will the CAP200D3 have?

Which carriers does Elite.Parts work with?

Will Elite.Parts sell to me even though I live outside the USA?

I have a preferred payment method. Will Elite.Parts accept it?

Why buy from GID?

Quality
We are industry veterans who take pride in our work

Protection
Avoid the dangers of risky trading in the gray market

Access
Our network of suppliers is ready and at your disposal

Savings
Maintain legacy systems to prevent costly downtime

Speed
Time is of the essence, and we are respectful of yours
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods