Elite.Parts chervon right Manufacturers chervon right C chervon right CARLO GAVAZZI chervon right G38900034230
About product Features Datasheet FAQ

CARLO GAVAZZI G38900034230

Image of CARLO GAVAZZI G38900034230

Description

Carlo Gavazzi G38900034230 Monitoring Controller. 115/230V AC

Part Number

G38900034230

Price

Request Quote

Manufacturer

CARLO GAVAZZI

Lead Time

Request Quote

Category

PRODUCTS - G

Features

Datasheet

pdf file

Carlo Gavazzi-G38900034230-datasheet1-152576214.pdf

96 KiB

Extracted Text

® Monitoring Controller Du line Type G 3890 0034 Fieldbus Installationbus • Channel generator and logging unit • Windows-based configuration software • Up to 112 AnaLink signals • Reading of analog and digital values via RS232 • Control of digital outputs via RS232 • Direct connection to printer through Centronics port • Print-outs of continuous-, daily or history reports • 48 loggins per point stored in EEPROM • ISA alarm monitoring • Alarm on-delay time configurable • Built-in realtime clock and display • 4 pushbuttons for manual operations • AC or DC power supply Product Description Ordering Key G 3890 0034 230 ® Generator controller 1 is de- is able to monitor up to 112 Type: Dupline signed for monitoring of ana- analog signals and generate Logging unit log signals, measured by 1- various reports on a standard Power supply channel AnaLink sensors. The IBM-graphics printer or com- generator, once configured, patible. Type Selection Input/Output Specifications Supply Ordering no. Serial Port RS 232, 9-pole female SUB-D Pin assignment T.D Pin 2 R.D Pin 3 115/230 VAC G 3890 0034 230 GND Pin 5 10 to 30 VDC G 3890 0034 800 RTS Pin 7 CTS Pin 8 Dielectric voltage Supply Specifications ® Com.port - Dupline‡2 kVAC (rms) Power supply AC-type Overvoltage cat. III (IEC 60664) Parallel Port Centronic Rated operational voltage 25-pole female SUB-D through term. 21 & 24 Pin assigment Strobe Pin 1 jumper term. 22 & 23 230 VAC ± 15% (IEC 60038) Data D0-D7 Pins 2-9 jumper term. 21 & 23 Busy Pin 11 Paper out Pin 12 and term. 24 & 22 115 VAC ± 15% (IEC 60038) GND Pins 18-25 Frequency 45 to 65 Hz Dielectric voltage Rated operational power Typ. 7 VA/3 W ® Com.port - Dupline‡2 kVAC (rms) Rated impulse withstand ® voltage 115/230 V 4 kV Output Dupline carrier Dielectric voltage Output voltage 8.2 V ® Supply - Dupline‡4 kVAC (rms) Current < 100 mA Short-circuit protection Yes Supply - Output‡4 kVAC (rms) Output impedance ≤ 15 Ω Supply - Input‡4 kVAC (rms) Sequence time Time for 1 pulse train ±1% Supply - Com. ports‡4 kVAC (rms) 32 channels 38.6 ms Power supply DC-type Overvoltage cat. III (IEC 60664) 128 channels 132.3 ms Rated operational voltage Analog channel update through term. 21 & 22 10 - 30 VDC 32 channels 9.75 s Reverse polarity protection Yes 128 channels 33.8 s Rated operational power 7 W Distance to AnaLink sensors See graph next page Inrush current 1 A Output 1 NPN transistor Rated impulse withstand Function Watchdog voltage 800 V Output voltage V ≤ 35 VDC DD Dielectric voltage Output current ≤ 100 mA ® Supply - Dupline 500 V Output voltage drop ≤ 2 V Supply - Output 200 V Off-state leakage current ≤ 100 μA Short-circuit protection None Built-in protective diodes None Dielectric voltage ® Output - Dupline‡4 kVAC (rms) Output - Input‡4 kVAC (rms) Inductive loads External noise sup. required Specifications are subject to change without notice (28.09.99) 1 ® Dupline is a registered trademark. A product of the CARLO GAVAZZI Group G 3890 0034 ® Du line Fieldbus Installationbus Input/Output Specifications (cont.) General Specifications Input Backup supply Real-time clock Function Real-time clock Accuracy Better than ± 1 minute/month Isolated in groups of 1 x 1 Internal backup time Typ. 120 hours Input voltage range 4.5 to 9 V Unit parameter backup time > 1 year Reverse polarity protection Yes Power ON delay < 2.5 s until start of Rated operational current 10 to 100 μA ® 1) Dupline carrier Input resistance > 47 kΩ Indication for Cable length < 0.5 m Supply ON LED, green Dielectric voltage ON Line LED, yellow ® Input - Dupline‡4 kVAC (rms) Busy LED, yellow Adjustment Time, Date, Year, Day Fault LED, red 4 tactile pushbuttons Manual reporting AM LED, yellow (Mode, Up, Down, Enter) Time, date etc. 4-digit LCD display red background light Environment Degree of protection IP 20 Distance versus No. of Sensors Pollution degree 3 (IEC 60664) Operating temperature 0° to +50°C (+32° to +122°F) DC loop Storage temperature -20° to +85°C (-4° to +185°F) resistance (Ω) Example: Max. distance for 75 sen- ^ 1/2 cable Humidity (non-condensing) 20 to 80% RH = sors D 8911 1010: 75 x 0.8 mA = 60 distance mA ⇒ loop resistance ~ 35 Ω. If 1.5 Mechanical resistance 2 mm cable @ 12 Ω/km is used, the Shock 15 G (11 ms) distance is: Vibration 2 G (6 to 55 Hz) 35 Ω = 1.45 km max. Dimensions 2 x 12 Ω/km Material (see "Technical Information") H8-housing Weight 540 g ® Dupline load (mA) 1) < 90 s until start of analog from AnaLink sen- measuring. sors Wiring Diagrams G 3890 0034 230 G 3890 0034 800 ® ® 0.1 A Dupline Dupline 0.1 A S S 35 V 35 V +- +- 1 2 3 4 5 6 7 8 9 10 111213 1415 16 1 2 3 4 5 6 7 8 9 10 111213 1415 16 Centronic Centronic Noise red. Noise red. Watchdog NPN Watchdog NPN RS 232 RS 232 +- 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 Backup Backup 4.5-9 V 4.5-9 V Supply Supply 10-30 VDC 7 W Power supply Power supply 230 VAC 115 VAC 2 Specifications are subject to change without notice (28.09.99) ® Dupline is a registered trademark. A product of the CARLO GAVAZZI Group G 3890 0034 ® Du line Fieldbus Installationbus Mode of Operation The G 3890 0034 230 is basically a channel generator which is Alarm Function capable of supplying and reading AnaLink sensors. It can operate If enabled, the controller con-tinuously checks the actual readings in two different ways: from AnaLink sensors for a value within free selectable upper and lower alarm limits. Any reading outside this bandwidth causes the 1) As a stand-alone unit (no PC required) with automated functions summary alarm channel B8 to turn ON. Additionally, a group like printing out reports of monitored analog signals and ISA alarm alarm channel turns ON for easier alarm localisation (B1 for Ana- monitoring of limit-values. Link sensors in groups C-D, B2 for sensors in groups E-F etc.) The alarming follows the ISA alarm sequencing and uses the fol- 2) As a digital and analog I/O-system for a PC or PLC through the lowing channels for control: RS232 port. Lamp test: A2 Configuration (required for stand-alone operation) Acknowledge: A3 The configuration is performed from a PC with a Windows based Reset: A4 Software supplied with the unit. Complete configurations can be Continuous up- and downloaded to the unit via a RS-232 link or stored to disk. report request: A5 From the Object Oriented Graphically menues all relevant parame- ters can be setup in a easy way. Alarm Suppression For every AnaLink sensor an ON-delay timer (0 - 255 m) may be * Basic functions, such as number of channels, number of analog assigned to suppress the alarm of its analog value. This function measuring points and logging intervals, are defined. may be used to suppress the alarm generation of the signal, e.g. during defrosting. * Specific functions for each block of 16measuring points are used for: Multiplex Analog Outputs - Enabling or disabling of measuring points. If enabled, multiplexed analog receivers (G 3496 6470) or displays - Assigning a specific Ana-Link sensor to a measuring point. (D 6369 6475) may be used to output the signals from AnaLink - Assigning alarm levels to a measuring point. sensors in analogue form or for display purposes. The AnaLink - Assigning descriptive text for reporting. sensors are related to receivers (display) as follows: * Range specification of 8 dif-ferent types of sensors in enginee- AnaLink Receiver Rec.Mux ring units. channel channel Address C1 C-D 0 Number of Dupline channels 128 C2 C-D 1 Number of analog points 0 .. . Dupline output mode Normal Dupline Operation .. . Parallel port Off .. . D8 C-D F Default Settings E1 E-F 0 The controller is shipped with the following settings: .. . .. . Setup .. . The four pushbuttons in the front are used together with the 4-digit P8 O-P F LCD display for the basic setup: setting time and date, selecting report print-outs, selecting printer operation and serial port opera- If the multiplexed analog output function is disabled, a digital tion etc. receiver coded to the same channel as the AnaLink sensor can be used to indicate an alarm condition of that sensor. Display Mode The display normally shows the For more information, please refer to user manual. actual time. By pressing either the UP-key or the Down-key, the month, day of week and year will be displayed. By pressing Enter, the software revision number will be displayed. With the Mode- key the setup changes from display mode to main settings mode. Main Settings Mode When entering the Main Set-tings Mode, the unit is in the setup menu and the display shows SEt. By pressing Enter the unit scrol- ls through the setup menu. By pressing Up or Down the unit scrolls through the main setting menu. Specifications are subject to change without notice (28.09.99) 3 ® Dupline is a registered trademark. A product of the CARLO GAVAZZI Group G 3890 0034 ® Du line Fieldbus Installationbus Key Operation Diagram D Date Day Year I Time S P Software L Revision A Y M A Setup Menu I [SEt] Set Time Set Date Set Set N Time Format Date Day Year Format [HrS] [For] [DAtE] [dAY] [YEAr] [For] day cent Hour EU_F Month S Ascending deca Min US_F date Descending E US format T T I Report Menu N [rEP] Continuous Daily Min/Max G Report Report Summary [Cont] [dAIL] [HISt] S M O D E Paper Length [PLEn] P_A4 P_A5 P_11 P_8.5 Legend Mode key Enter key Up key Down key 4 Specifications are subject to change without notice (28.09.99) ® Dupline is a registered trademark. A product of the CARLO GAVAZZI Group G 3890 0034 ® Du line Fieldbus Installationbus Pin Assignment RS 232 Cables 9-pin male 9-pin female to controller to PC 1 5 2 2 3 3 6 9 5 5 Pin Signal 7 7 2 T x D 8 8 3 R x D 5 Signal Ground 7RTS 8 CTS 25-pin female 9-pin male to PC to controller 13 1 2 2 3 3 25 14 7 4 Pin Signal 8 5 1 Strobe 6 2-9 Do - D7 11 Busy 5 7 12 Paper out 20 18-25 GND Scope of Supply Accessories 1 x Monitoring Controller D 3890 0034 .. User manual MAN G 3890 0034 ENG 1 x AnaLink Sensor coding cable GTS-CAB RS 232 cable (9 pole F) RS 232-9 M/9 F 1 x User Manual MAN G 3890 0034 ENG 1 x RS 232 cable RS 232-9 M/9F 1 x Configurations software SW G3890 0034 Specifications are subject to change without notice (28.09.99) 5 ® Dupline is a registered trademark. A product of the CARLO GAVAZZI Group

Frequently asked questions

What makes Elite.Parts unique?

chervon down
At GID Industrial (Elite.Parts' parent company), we specialize in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

What kind of warranty will the G38900034230 have?

chervon down
Warranties differ by part and by which suppliers we use to procure it for you. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carriers does Elite.Parts work with?

chervon down
Elite.Parts can ship via FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Will Elite.Parts sell to me even though I live outside the USA?

chervon down
Absolutely! We are happy to serve customers regardless of location. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

I have a preferred payment method. Will Elite.Parts accept it?

chervon down
All major credit cards are accepted: Visa, MasterCard, Discover, and American Express. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

Dupline Field and Installlation Bus

Carlo Gavazzi - Digital Input Module

Carlo Gavazzi - Digital Input Module

Carlo Gavazzi - Digital Output Module

Carlo Gavazzi - Digital Output Module

product

Carlo Gavazzi G21404421700 - I/O Module for Elevators, Type G