Elite.Parts chervon right Manufacturers chervon right C chervon right CARLING TECHNOLOGIES chervon right CF1-B0-14-810-33D-MG
About product Specifications Datasheet FAQ

CARLING TECHNOLOGIES CF1-B0-14-810-33D-MG

Description

Carling Technologies CF1-B0-14-810-33D-MG Circuit Breaker - 100 Amp Circuit Breaker

Part Number

CF1-B0-14-810-33D-MG

Price

Request Quote

Manufacturer

CARLING TECHNOLOGIES

Lead Time

Request Quote

Category

PRODUCTS - C

Specifications

Actuator Type

Rocker

Current Rating

100 A

Mounting

Screw

Number of Poles

1

Terminal Design

Stud

Voltage Rating

480|277 Vac

Datasheet

pdf file

Carling-HM-CB-C-Series-7320922.pdf

5471 KiB

Extracted Text

C-Series Circuit Breaker The C-Series hydraulic/magnetic circuit breakers are ideal for applications that require higher amperage and voltage handling capability in a smaller package. They are available in 1-6 poles, 0.02-100amps, UL Recognized up to 480VAC or 150VDC, UL489 Listed up to 240VAC or 125VDC, with choice of time delays, terminal options, actuator HANDLE ACTUATOR METAL TOGGLE ACTUATOR styles and colors. Product Highlights: Š The UL489 C-Series employs a unique arc chute design which allows for higher interrupting capacities of up to 10,000 amps. New thermoset glass filled polyester half shell construction provides for increased mechanical and electrical strength. The wiping contacts, mechanical linkage with two step actuation, clean contacts providing high, positive contact pressure and longer contact life PARALLEL POLE ACTUATOR Š Available with American Standard or Metric Threaded Stud terminals, or Saddle Clamp screw terminals. Optional mid-trip handle style actuator allows visual Agency Certifications: indication of electrical overload with or without alarm UL Recognized | feature UL Standard 1077 UL Standard 508 Š Available with new solid color rocker actuators and UL Standard 1500 unique two-color Visi-rocker® actuators, which can be UL Listed | specified to indicate either the ON or TRIPPED/OFF UL Standard 489 UL Standard 489A | mode CSA Accepted CSA Certified | Š Exclusive Rockerguard and Push-To-Reset bezel help TUV Certified VDE Certified prevent inadvertent actuation * For full Agency Certifications, please see pg. 6 Carling Technologies, Inc. 60 Johnson Avenue • Plainville, CT 06062-1177 Phone: (860) 793-9281 • Fax: (860) 793-9231 Email: sales@carlingtech.com • www.carlingtech.com | 2 C-Series – General Specifications Electrical Tables Table A: Lists UL Recognized & CSA Accepted configurations and performance capabilities as a Component Supplementary Protector 150 80-100 TC1, OLO, U3 Agency Code L 150 101-175 TC, OLO, U3 Agency Code L Parallel Pole Notes for Table A: 1 Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse rated 15A minimum and no more than 4 times full load amps not to exceed 125A for 50 Amp or less rating and not to exceed 175 for 51 through 100 Amp rating *Manufacturer reserves the right to change product specification without prior notice. 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 Email: sales@carlingtech.com • www.carlingtech.com | C-Series – General Specifications 3 Electrical Tables Table B: Lists UL Recognized and CSA Accepted configurations and performance capabilities as a Manual Motor Controller. RELAY Notes for Table B: 1 UL recognized and CSA Accepted at 480V refers to 3 & 4 pole versions used in a 3Ø, wye connected circuit or 2-pole version connected with 2 poles breaking. 1Ø and backed up with series fusing as stated above in note 1. * Series, Shunt and Relay Trip - Voltage Coil Construction not current coils Table C: Lists UL Recognized, CSA Accepted , VDE and TUV Certified configurations and performance capabilities as a Component Supplementary Protector. Notes for Table C: 1 General Purpose ratings for UL/CSA only. 2 Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse rated 15A minimum and no more than 4 times full load amps not to exceed 125A for 50 Amp or less rating and not to exceed 175 for 51 through 100 Amp rating. 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 Email: sales@carlingtech.com • www.carlingtech.com Email: sales@carlingtech.com • www.carlingtech.com | 4 C-Series – General Specifications Electrical Tables Table D: Lists UL Listed (489), CSA Certified (C22.2 No. 5.1-M) configuration and performance capabilities as a Molded Case Circuit Breaker. C SERIES TABLE D : UL489 LISTED BRANCH CIRCUIT BREAKERS INTERRUPTING CURRENT VOLTAGE CAPACITY RATING CIRCUIT (AMPS) CONSTRUCTION NOTES CONFIGURATION MAX. FULL LOAD WITHOUT FREQUENCY PHASE RATING AMPS BACKUP FUSE 1 Limited to 2 Poles Max from 71 - 100 Amps. 50,000 80 DC --- 0.10 - 100 10,000 Limited to 2 Poles Max from 71 - 100 Amps. 125 DC --- 0.10 - 100 5,000 1 - 3 Poles 125 / 250 DC --- 0.10 - 50 5,000 1 or 2 Poles (2 Poles Required for 250 Volts) 0.10 - 50 10,000 1 - 3 Poles 120 50 / 60 1 SERIES 51 - 70 5,000 1 - 3 Poles 0.10 - 50 5,000 2 or 3 Poles. 1 Pole of a 3 Pole Unit is Neutral 120 / 240 50 / 60 1 1 2 or 3 Poles. 1 Pole of a 3 Pole Unit is Neutral 0.10 - 50 10000 240 50 / 60 10.10 - 30 5,000 1Pole 240 50 / 60 10.10 - 20 5,0002 Pole 277 50 / 60 10.10 - 20 10,000 1Pole DUAL COIL 120 50 / 60 10.10 - 30 10,000 --- Notes from Table D: 1 Special catalog number required. Consult factory. Table E: Lists UL Recognized, CSA Accepted configurations and performance capabilities as Protectors, Supplementary for Marine Electrical and Fuel Systems (Guide PEQZ2, File E75596). Ignition Protected per UL 1500. UL Classified Small Craft Electrical Devices, Marine in accordance with ISO 8846 (Guide UZMK, File MQ1515) as Marine Supplementary Protectors. Table F: Lists UL Listed configurations and performance capabilities as Circuit Breakers for use in Communications Equipment (Guide DITT, File E189195), under UL489A. 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 Email: sales@carlingtech.com • www.carlingtech.com | C-Series – General Specifications 5 Electrical Mechanical Endurance 10,000 ON-OFF operations @ 6 per Maximum Voltage AC, 480 WYE/277 VAC, 50/60 Hz (see Table A.) minute; with rated current & voltage UL489: AC,240 VAC. (Table D), Trip Free All C-Series circuit breakers will trip 50/60 Hz, 125 VDC, UL 1077, on overload, even when actuator is 150 VDC, 277 VAC forcibly held in the ON position. Trip Indication The operating actuator moves Current Rating Standard current coils: 0.100, 0.250, 0.500, 0.750, 1.00, 2.50, positively to the OFF position when 5.00, 7.50, 10.0, 15.0, 25.0, 30.0, an overload causes the breaker to 35.0, 40.0, 50.0, 60.0, 70.0, 80.0, trip. With mid-trip, handle moves to 90.0 and 100 amps. Other ratings the mid position on electrical trip of the circuit breaker. With mid trip available, see Ordering Scheme. Standard Voltage Coils DC - 6V, 12V; AC - 120V; other handle with alarm switch, handle ratings available, see Ordering moves to the mid position and Scheme. the alarm switch actuates when Auxiliary Switch Rating SPDT; 10.1 amps-250VAC, DC the circuit breaker is electrically tripped. Aux. Switch 1.0A, 65 VDC. 0.5A, 80VDC,1/4 HP, 125VAC,VDE & TUV 1.0 125 VAC. Physical Insulation Resistance Minimum of 100 Megohms at 500 VDC. Number of Poles 1-6 poles ≤ 50A; 1-4 poles @ 51- Dielectric Strength UL, CSA: 1960 V 50/60 Hz for one 70A; 1-2 poles 71-100A. UL489 minute between all electrically Handle: 1 pole ≤ 100A, 2 pole ≤ isolated terminals. C-Series 50A; Rocker: 1 pole ≤ 100A. Circuit Breakers comply with the Internal Circuit Configuration Series (with or without auxiliary 8mm spacing and 3750V 50/60 switch, mid trip & mid trip with Hz dielectric requirements from alarm switch) Shunt & Relay with hazardous voltage to operator current or voltage trip coils, Dual accessible surfaces, between Coil, Switch Only (with or without adjacent poles and from main aux. switch). UL489: Series (with or circuits to auxiliary circuits per without auxiliary switch, mid-trip & Publications EN 60950 and VDE mid-trip with alarm switch). 0805. Weight Approx.112 grams/pole ( 3.95 oz). Resistance, Impedance Values from Line to Load Terminal Standard Colors Housing: Black based on Series Trip Circuit RESISTANCE, IMPEDANCE VALUES Breaker. Environmental from Line to Load Terminals (Values Based on Series Trip Circuit Breaker ) Designed and tested in accordance with requirements of 1000 CURRENT specification MIL-PRF-55629 & MIL-STD-202 as follows: TOLERANCE (AMPS) (%) 100 Shock Withstands 100 Gs, 6ms sawtooth 0.10 - 5.0 ± 15% while carrying rated current per 10 5.1 - 20.0 ± 25% Method 213, Test Condition “I”. O 20.1 - 100.0 ± 35% Instantaneous and ultrashort curves H 1 tested @ 90% of rated current. M S 60 Hz 1/2 Cycle Vibration Withstands 0.060” excursion from Inrush Pulse Tolerance 0.1 I r Time Delay Curves 10-55 Hz & 10 Gs 55-500 Hz, @ 42, 44 & 46 (50 Amps Max.) 25x 0.01 rated current per Method 204C, Time Delay Curves 22, 24 (100 Amps Max.) Test Cond. A. Instantaneous & 12x 26 (70 Amps Max.) 0.001 ultrashort curves tested @ 90% of 0.01 0.1 1 10 100 t AMPERE RATING  8.33 16.67 4.165 rated current. CURRENT TOLERANCE Moisture Resistance Method 106D, i.e., ten 24-hour (AMPS) (%) Pulse Tolerance Curves 0.100 - 5.0  ± 15% 5.1 - 20.0 ± 25% cycles @ +25°C to +65°C, 80-98% 60 Hz 1/2 Cycle 50 Hz 1/2 Cycle Inrush Pulse 20.1 - 100 Tolerance   ± 35% Inrush Pulse Tolerance I I r r RH. Time Delay Cur FIGURE 1 ves  Time Delay Curves 42, 44 & 46 22x 42, 44 & 46 (50 Amps Max.) 25x (50 Amps Max.) Salt Spray Method 101, Condition A (90-95% Time Delay Curves Time Delay Curves 10x 22, 24 (100 Amps Max.) 22, 24 (100 Amps Max.) RH @ 5% NaCl Solution, 96 hrs). 12x 26 (70 Amps Max.) 26 (70 Amps Max.) t Method 107D, Condition A (five t 10.0 20.0 5.0 8.33 4.165 16.67 Time in  Thermal Shock cycles @ -55°C to +25°C to +85°C Milliseconds to +25°C). 50 Hz 1/2 Cycle Operating Temperature -40°C to +85°C I Inrush Pulse Tolerance r Time Delay Curves 22x 42, 44 & 46 (50 Amps Max.) Time Delay Curves 10x 22, 24 (100 Amps Max.) 26 (70 Amps Max.) t 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 10.0 20.060 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 5.0 Time in  Milliseconds Email: sales@carlingtech.com • www.carlingtech.com Email: sales@carlingtech.com • www.carlingtech.com Multiple of Multiple of Rated Current Rated Current Multiple of Multiple of Rated Current Rated Current | 6 C-Series - Agency Certifications Agency Certifications: UL Recognized UL Standard 1077 Component Recognition Program as Protectors, Supplementary (Guide CCN/QVNU2, File E75596) UL Standard 508 Motor Controllers, Manual (Guide CCN/NLRV2, File E135367) UL Standard 1500 Protectors, Supplementary for Marine Electrical & Fuel Systems (Guide PEQZ2, File E75596) Ignition Protection UL Listed UL Standard 489 Circuit Breakers, Molded Case, (Guide DIVQ, File E129899) UL Standard 489A Communications Equipment (Guide CCN/DITT, File E189195) CSA Accepted Component Supplementary Protector under Class 3215 30, File 047848 0 000 CSA Standard C22.2 No. 235 CSA Certified Circuit Breaker Model Case (Class 1432 01, File 093910), CSA Standard C22.2 No. 5.1 - M TUV Certified EN60934, under License No. R72041016 VDE Certified EN60934, VDE 0642 under File No. 10537 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 Email: sales@carlingtech.com • www.carlingtech.com | C-Series Handle UL Recognized – Ordering Scheme 7 C A 3 — B 0 — 10 — 450 — 1 2 1 — C 1 2 3 4 5 6 7 8 9 10 11 Terminal Actuator Mounting Agency Series Actuator Poles Circuit Aux/Alarm Frequency Current Rating Color Bezel/Barrier Approval Switch & Delay 1 SERIES 7 CURRENT RATING (AMPERES) CODE AMPERES C 020 0.020 235 0.350 430 3.000 614 14.000 025 0.025 240 0.400 435 3.500 615 15.000 1 2 ACTUATOR 030 0.030 245 0.450 440 4.000 616 16.000 A Handle, one per pole 035 0.035 250 0.500 445 4.500 617 17.000 B Handle, one per multipole unit 040 0.040 255 0.550 450 5.000 618 18.000 S Mid-Trip Handle, one per pole 045 0.045 260 0.600 455 5.500 620 20.000 T Mid-Trip, one per pole & Alarm Switch 050 0.050 265 0.650 460 6.000 622 22.000 055 0.055 270 0.700 465 6.500 624 24.000 060 0.060 275 0.750 470 7.000 625 25.000 2 3 POLES 065 0.065 280 0.800 475 7.500 630 30.000 1 One 3 Three 5 Five 070 0.070 285 0.850 480 8.000 635 35.000 2 Two 4 Four 6 Six 075 0.075 290 0.900 485 8.500 640 40.000 080 0.080 295 0.950 490 9.000 650 50.000 9 085 0.085 410 1.000 495 9.500 660 60.000 3 4 4 CIRCUIT F Relay Trip (current) 9 090 0.090 512 1.250 610 10.000 670 70.000 3 4 A Switch Only (no coil) G Relay Trip (voltage) 9 095 0.095 415 1.500 710 10.500 680 80.000 4,5 B Series Trip (current) H Dual Coil with Shunt Trip 9 210 0.100 517 1.750 611 11.000 685 85.000 C Series Trip (voltage) Voltage Coil 9 215 0.150 420 2.000 711 11.500 690 90.000 4 4,5 D Shunt Trip (current) K Dual Coil with Relay Trip 9 220 0.200 522 2.250 612 12.000 695 95.000 4 E Shunt Trip (voltage) Voltage Coil 9 225 0.250 425 2.500 712 12.500 810 100.000 230 0.300 527 2.750 613 13.000 7 VOLTAGE COIL (NORMINAL RATED VOLTAGE) 5 AUXILIARY/ALARM SWITCH 5 S.P.S.T., 0.110 Q.C. Term. CODE RATING 0 w/o Aux Switch (Gold Contacts) A06 6DC A32 32DC J12 12AC J65 65AC 2 S.P.D.T., 0.110 Q.C. Term. 6 S.P.S.T., 0.139 Solder Lug A12 12DC A48 48DC J18 18AC K20 120AC 3 S.P.D.T., 0.139 Solder Lug 7 S.P.S.T., 0.110 Q.C. Term. A18 18DC A65 65DC J24 24AC L40 240AC 4 S.P.D.T., 0.110 Q.C. Term. (Gold Contacts) A24 24DC J06 6AC J48 48AC (Gold Contacts) 8 S.P.S.T., 0.187 Q.C. Term. 9 S.P.D.T., 0.187 Q.C. Term. 15 12 8 TERMINAL 6 Screw M6, threaded 10 13,15 6 FREQUENCY & DELAY 1 Stud 10-32, threaded 7 0.250 Double Click Connect 3 11 15 03 DC 50/60Hz, Switch Only 30 DC 50/60Hz Instantaneous 2 Screw 10-32 8 1/4” Clip Terminal 7 12 12,15 10 DC Instantaneous 31 DC 50/60Hz Ultra Short 3 Screw 1/4-20, threaded 9 7/16” Clip Terminal 11 14 11 DC Ultra Short 32 DC 50/60Hz Short 4 Screw M5 x 0.8, threaded A Plug-In Stud 11 11,15 12 DC Short 34 DC 50/60Hz Medium 5 Screw M5 x 0.8 C 5/16” Clip Terminal 14 DC Medium 36 DC 50/60Hz Long 8 16 DC Long 42 50/60Hz Short, Hi-Inrush 7 8 16 20 50/60Hz Instantaneous 44 50/60Hz Medium, Hi-Inrush 9 ACTUATOR COLOR & LEGEND 8 21 50/60Hz Ultra Short 46 50/60Hz Long, Hi-Inrush Actuator Color I-O ON-OFF Dual Legend Color 8 22 50/60Hz Short 52 DC Short, Hi-Inrush White A B 1 Black 8 24 50/60Hz Medium 54 DC Medium, Hi-Inrush Black C D 2 White 26 50/60Hz Long 56 DC Long, Hi-Inrush Red F G 3 White Green H J 4 White Notes: Blue K L 5 White 1 Actuator Code: Yellow M N 6 Black A: Handle tie pin spacer(s) and retainers provided assembled with multi-pole units. Gray B: Handle location as viewed from front of breaker: P Q 7 Black Orange 2 pole - left pole 3 pole - center pole 4 pole - two handles at center poles R S 8 Black 17 5 pole - three handles at center poles 6 pole - four handles at center poles Black (short handle) T U 9 White S: Handle moves to mid-position only upon electrical trip of the breaker. Available with circuit codes B, C, D, E, F, G, H and K. T: Handle moves to mid-position and alarm switch activates only upon electrical trip of 10 MOUNTING/BARRIERS the breaker. Available with circuit codes B & C. MOUNTING STYLE BARRIERS VOLTAGE 2 Standard multipole units have all poles identical except when specifying auxilary switch Threaded Insert and/or mixed poles. 4 pole max w/VDE. 5th pole available as Series Trip w/Voltage Coil only. < 1 6-32 x 0.195 inches no 300 3 Switch Only circuits, rated up to 50 amps and 6 poles, and only available with VDE Certi- < fication when tied to a protected pole (Circuit Code B, C, D or H.). For .02 to 30 amps, A 6-32 x 0.195 inches yes 300 18 > select Current Code 630. For 35 - 50 amps, select Current Code 650. For 55-70 amps, C 6-32 x 0.195 inches yes 300 – select Current Code 670. For 75-100 amps, select Current Code 810. < 2 ISO M3 x 5mm no 300 4 Circuit Codes D,E,F,G,H & K available with Terminal Codes 1,2,4 & 5 only. Circuit Codes < B ISO M3 x 5mm yes 300 D, F, H & K available up to 50 amps maximum Current Rating. 18 > D ISO M3 x 5mm yes 300 – 5 Consult factory for available Dual Coil options, as special catalog number is required. Front Panel Snap-In, 1.00” [25.4mm] wide bezel Dual Coil Voltage Coils with Shunt Trip Construction trip instantaneously on line voltage. 17 < E with Handleguard no 300 Dual Coil Voltage Coils require 30VA minimum power to trip instantaneously and are rated for intermittent duty only. 6 ers, one aux. switch is supplied, mounted in the extreme right pole. Voltage coils not rated for continuous duty. Available only with delay codes 10 and 20. 11 AGENCY APPROVAL 7 Available with Circuit Codes B & D only, and up to 50 amps maximum. C UL Recognized, CSA Accepted 8 Current Ratings 60 - 70 are available up to four poles maximum. Ratings 71 - 100 are D VDE Certified, UL Recognized, CSA Accepted 9 available up to two poles maximum. E TUV Certified, UL Recognized, CSA Accepted Terminal Code 1 available to 60 amps maximum. H UL489 Construction: VDE Certified, UL Recognized, CSA Accepted 10 Terminal Codes 2,4,5 and C available to 50 amps maximum. I UL Rec. STD 1077, UL Rec. 1500 (ignition protected), CSA Accepted 11 Terminal Codes 3,6 & 9 available to 100 amps maximum. L UL489 Construction: UL Recognized, CSA Accepted 12 Terminal Code 7 available to 25 amps maximum. R UL489 Construction: TUV Certified, UL Recognized, CSA Accepted 13 Terminal Code A available to 100 amps maximum. 14 Terminal Codes 7,8,9 & C are not VDE approved. 15 No marking available. Consult factory. VDE/TUV Approval requires dual (I-O, ON-OFF) 16 or I-O markings on all handles. Single pole only. 17 VDE/TUV: 30 amps max.; UL/CSA: 50 amps max.; Available in 2 - 4 poles only and 18 limited to AC Delays. “General Purpose amps” not rated for “full load amps” or to be used in applications with a motor. 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 Email: sales@carlingtech.com • www.carlingtech.com Email: sales@carlingtech.com • www.carlingtech.com | 8 C-Series Handle Parallel Pole UL489A Listed – Ordering Scheme C A 2 — P 0 — D4 — 820 — 3 2 1 — M T 1 2 3 4 5 6 7 8 9 10 11 12 Terminal Actuator Mounting Max. App. Agency Series Actuator Poles Circuit Aux/Alarm Frequency Current Rating Color Rating Approval Switch & Delay 2 8 TERMINAL 1 SERIES 3 1/4-20, threaded C 6 M6, threaded A Plug-In Stud 1 2 ACTUATOR A Handle, one per pole S Mid-Trip Handle, one per pole 9 ACTUATOR COLOR T Mid-Trip, one per pole & Alarm Switch LEGEND ON-OFF Dual Legend Color White B 1 Black 3 3 POLES Black D 2 White 2 Two 3 Three Red G 3 White Green J 4 White Blue L 5 White 4 CIRCUIT Yellow N 6 Black P Series Trip (parallel pole) Gray Q 7 Black Orange S 8 Black 5 AUXILIARY/ALARM SWITCH 5 S.P.S.T., 0.110 Q.C. Term. 0 w/o Aux Switch (Gold Contacts) 10 MOUNTING/BARRIERS 2 S.P.D.T., 0.110 Q.C. Term. 6 S.P.S.T., 0.139 Solder Lug MOUNTING STYLE 3 S.P.D.T., 0.139 Solder Lug 7 S.P.S.T., 0.110 Q.C. Term. Threaded Insert 4 S.P.D.T., 0.110 Q.C. Term. (Gold Contacts) 1 6-32 x 0.195 inches (Gold Contacts) 8 S.P.S.T., 0.187 Q.C. Term. 2 ISO M3 x 5mm 9 S.P.D.T., 0.187 Q.C. Term. 11 MAXIMUM APPLICATION RATING 6 FREQUENCY & DELAY M 80 DC D1 DC Ultra Short D4 DC Medium D2 DC Short D6 DC Long 12 AGENCY APPROVAL T UL489A Listed (up to 250 amps) 7 CURRENT RATING (AMPERES) K UL489A Listed, VDE Certified (up to 200 amps) CODE AMPERES 7 UL489A Listed, TUV Certified (up to 250 amps) 3 811 110.000 814 140.000 917 170.000 922 225.000 3 812 120.000 815 150.000 818 180.000 825 250.000 912 125.000 816 160.000 819 190.000 813 130.000 817 170.000 820 200.000 Notes: 1 Actuator Code: A: Handle tie pin spacer(s) and retainers provided assembled with multi-pole units. S: Handle moves to mid-position only upon electrical trip of the breaker. T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the breaker. 2 Terminal Code: 3 & 6: Supplied with bus bars connecting the Line and Load Terminals. A: Line and Load Terminals must be connected to a copper bus bar having a minimum cross section of 0.078 square inches. 3 Above 200 amps, 3 poles are required. 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 Email: sales@carlingtech.com • www.carlingtech.com | C-Series Handle UL489 Listed – Ordering Scheme 9 C A 3 — B 0 — 14 — 450 — 1 2 1 — K G 1 2 3 4 5 6 7 8 9 10 11 12Agency Terminal Actuator Mounting/ Max. App. Approval Series Actuator Poles Circuit Aux/Alarm Frequency Current Rating Color Barriers Rating Switch & Delay 5 1 SERIES 7 CURRENT RATING (AMPERES) CODE AMPERES C 210 0.100 295 0.950 470 7.000 618 18.000 215 0.150 410 1.000 475 7.500 620 20.000 1 2 ACTUATOR 220 0.200 512 1.250 480 8.000 622 22.000 A Handle, one per pole 225 0.250 415 1.500 485 8.500 624 24.000 B Handle, one per multipole unit 230 0.300 517 1.750 490 9.000 625 25.000 S Mid-Trip Handle, one per pole 235 0.350 420 2.000 495 9.500 630 30.000 T Mid-Trip, one per pole & Alarm Switch 240 0.400 522 2.250 610 10.000 635 35.000 245 0.450 425 2.500 710 10.500 640 40.000 250 0.500 527 2.750 611 11.000 660 60.000 2 3 POLES 255 0.550 430 3.000 711 11.500 670 70.000 1 One 2 Two 3 Three 260 0.600 435 3.500 612 12.000 680 80.000 265 0.650 440 4.000 712 12.500 685 85.000 270 0.700 445 4.500 613 13.000 690 90.000 4 CIRCUIT 275 0.750 450 5.000 614 14.000 695 95.000 B Series Trip (current) 280 0.800 455 5.500 615 15.000 810 100.000 285 0.850 460 6.000 616 16.000 290 0.900 465 6.500 617 17.000 3 5 AUXILIARY/ALARM SWITCH 5 S.P.S.T., 0.110 Q.C. Term. 0 w/o Aux Switch (Gold Contacts) 6 9 2 S.P.D.T., 0.110 Q.C. Term. 6 S.P.S.T., 0.139 Solder Lug 8 TERMINAL 6 Screw M6, threaded 7 3 S.P.D.T., 0.139 Solder Lug 7 S.P.S.T., 0.110 Q.C. Term. 1 Stud 10-32, threaded 8 1/4” Clip Terminal 8 9 4 S.P.D.T., 0.110 Q.C. Term. (Gold Contacts) 2 Screw 10-32 9 7/16” Clip Terminal 9 10 (Gold Contacts) 8 S.P.S.T., 0.187 Q.C. Term. 3 Screw 1/4-20, threaded A Plug-In Stud 8 9 S.P.D.T., 0.187 Q.C. Term. 4 Screw M5 x 0.8, threaded C 5/16” Clip Terminal 8 5 Screw M5 x 0.8 6 FREQUENCY & DELAY 26 50/60Hz Long 4 11 DC Ultra Short 42 50/60Hz Short, Hi-Inrush 11 9 ACTUATOR COLOR & LEGEND 4 12 DC Short 44 50/60Hz Medium, Hi-Inrush Actuator Color ON-OFF Dual Legend Color 4 14 DC Medium 46 50/60Hz Long, Hi-Inrush White B 1 Black 4 16 DC Long 52 DC Short, Hi-Inrush Black D 2 White 4 21 50/60Hz Ultra Short 54 DC Medium, Hi-Inrush Red G 3 White 4 22 50/60Hz Short 56 DC Long, Hi-Inrush Green J 4 White 24 50/60Hz Medium Blue L 5 White Yellow N 6 Black Notes: Gray Q 7 Black 1 Actuator Code: Orange S 8 Black A: Handle tie pin spacer(s) and retainers provided assembled with multi-pole units. B: Handle located, as viewed from front of breaker in left pole. 2 pole maximum. S: Handle moves to mid-position only upon electrical trip of the breaker. T: Handle moves to mid-position and alarm switch activates only upon electrical trip of 10 MOUNTING/BARRIERS 12 the breaker. MOUNTING STYLE BARRIERS 2 Standard multipole units have all poles identical except when specifying auxiliary switch Threaded Insert and/or mixed poles. 1 6-32 x 0.195 inches yes 2 & 3 pole circuit breakers required for 120/240 VAC (Maximum application rating code 2 ISO M3 x 5mm yes C) applications, have all poles identical except when specifying auxiliary / alarm switch which is normally supplied in extreme right pole per figure B. Terminal barriers are required on all multipole breakers. Third pole is for 120/240 VAC applications requiring neutral disconnect. The 3rd pole has 11 MAXIMUM APPLICATION RATING the same construction as poles 1 & 2. A 65 DC 3 On multi-pole breakers, one auxiliary. switch is supplied, mounted in the extreme right pole. B 125 DC VDE approval on auxiliary switch codes 2, 3 & 4 only. 2 C 120/240 AC Auxiliary / Alarm Switch with Independent Circuit ie: separate from breaker circuit, D 240 AC only available with circuit breakers rated 50 amp maximum at 80 VDC, 125 VDC, and K 120 AC 120 VAC. Auxiliary / Alarm Switch with Dependent Circuit ie: same as circuit breaker, is supplied from factory with common terminal of auxiliary / alarm switch connected to M 80 DC line terminal on 120/240 and 240 VAC ratings. Circuit breakers rated 120 VAC 50 amp maximum can be supplied with Auxiliary/Alarm switch common terminal connected to breaker line terminal. Consult factory for special catalog number. 11 12 AGENCY APPROVAL 4 Available up to 50 amps maximum. A w/o approvals 5 Current ratings 71 - 100 with VDE approvals are available up to two poles maximum. F UL489 Listed, VDE Certified, CSA Accepted 6 Terminal Codes 8, 9 & C are not VDE approved. G UL489 Listed, CSA Accepted 7 Terminal Code 1 available to 60 amps maximum. J UL489 Listed, TUV Certified, CSA Accepted 8 Terminal Codes 2, 4, 5 & C available to 50 amps maximum. 9 Terminal Codes 3, 6 & 9 available to 100 amps maximum. 10 Terminal Code A available to 100 amps maximum. 11 VDE and TUV approvals require Dual (I-O, ON-OFF) markings on all handles. 12 Barriers supplied on multi-pole units only. 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 Email: sales@carlingtech.com • www.carlingtech.com Email: sales@carlingtech.com • www.carlingtech.com | 10 C-Series Sealed Toggle UL Recognized – Ordering Scheme C M 3 — B 0 — 10 — 450 — 1 0 1 — C 1 2 3 4 5 6 7 8 9 10 11 Terminal Legend Mounting Agency Series Actuator Poles Circuit Aux/Alarm Frequency Current Rating Plate Bezel/Barrier Approval Switch & Delay 9 1 SERIES 7 CURRENT RATING (AMPERES) CODE AMPERES C 020 0.020 235 0.350 430 3.000 614 14.000 025 0.025 240 0.400 435 3.500 615 15.000 1 2 ACTUATOR 030 0.030 245 0.450 440 4.000 616 16.000 M Sealed Toggle, one per pole 035 0.035 250 0.500 445 4.500 617 17.000 040 0.040 255 0.550 450 5.000 618 18.000 045 0.045 260 0.600 455 5.500 620 20.000 050 0.050 265 0.650 460 6.000 622 22.000 3 POLES 055 0.055 270 0.700 465 6.500 624 24.000 1 One 2 Two 3 Three 060 0.060 275 0.750 470 7.000 625 25.000 065 0.065 280 0.800 475 7.500 630 30.000 3 070 0.070 285 0.850 480 8.000 635 35.000 4 CIRCUIT F Relay Trip (current) 2 3 075 0.075 290 0.900 485 8.500 640 40.000 A Switch Only (no coil) G Relay Trip (voltage) 3,4 080 0.080 295 0.950 490 9.000 650 50.000 B Series Trip (current) H Dual Coil with Shunt Trip 9 085 0.085 410 1.000 495 9.500 660 60.000 C Series Trip (voltage) Voltage Coil 9 3 3,4 090 0.090 512 1.250 610 10.000 670 70.000 D Shunt Trip (current) K Dual Coil with Relay Trip 9 3 095 0.095 415 1.500 710 10.500 680 80.000 E Shunt Trip (voltage) Voltage Coil 9 210 0.100 517 1.750 611 11.000 685 85.000 9 215 0.150 420 2.000 711 11.500 690 90.000 9 5 AUXILIARY/ALARM SWITCH 5 S.P.S.T., 0.110 Q.C. Term. 220 0.200 522 2.250 612 12.000 695 95.000 9 0 w/o Aux Switch (Gold Contacts) 225 0.250 425 2.500 712 12.500 810 100.000 2 S.P.D.T., 0.110 Q.C. Term. 6 S.P.S.T., 0.139 Solder Lug 230 0.300 527 2.750 613 13.000 3 S.P.D.T., 0.139 Solder Lug 7 S.P.S.T., 0.110 Q.C. Term. 7 VOLTAGE COIL (NORMINAL RATED VOLTAGE) 4 S.P.D.T., 0.110 Q.C. Term. (Gold Contacts) CODE RATING (Gold Contacts) 8 S.P.S.T., 0.187 Q.C. Term. A06 6DC A32 32DC J12 12AC J65 65AC 9 S.P.D.T., 0.187 Q.C. Term. A12 12DC A48 48DC J18 18AC K20 120AC A18 18DC A65 65DC J24 24AC L40 240AC A24 24DC J06 6AC J48 48AC 6 FREQUENCY & DELAY 2 03 DC 50/60Hz, Switch Only 30 DC 50/60Hz Instantaneous 6 10 DC Instantaneous 31 DC 50/60Hz Ultra Short 11 8 TERMINAL 6 Screw M6, threaded 11 DC Ultra Short 32 DC 50/60Hz Short 9 12 1 Stud 10-32, threaded 7 0.250 Double Click Connect 12 DC Short 34 DC 50/60Hz Medium 10 2 Screw 10-32 8 1/4” Clip Terminal 14 DC Medium 36 DC 50/60Hz Long 11 11 7 3 Screw 1/4-20, threaded 9 7/16” Clip Terminal 16 DC Long 42 50/60Hz Short, Hi-Inrush 10 13 6 7 4 Screw M5 x 0.8, threaded A Plug-In Stud 20 50/60Hz Instantaneous 44 50/60Hz Medium, Hi-Inrush 10 10 7 5 Screw M5 x 0.8 C 5/16” Clip Terminal 21 50/60Hz Ultra Short 46 50/60Hz Long, Hi-Inrush 7 22 50/60Hz Short 52 DC Short, Hi-Inrush 7 24 50/60Hz Medium 54 DC Medium, Hi-Inrush 9 LEGEND PLATE 26 50/60Hz Long 56 DC Long, Hi-Inrush 0 No Legend Notes: 1 Actuator Code M: Handle location as viewed from front of breaker: 2 pole - right pole 3 pole - center pole 10 MOUNTING/BARRIERS 2 Switch Only circuits, rated up to 50 amps and 3 poles, and only available with VDE. For MOUNTING STYLE BARRIERS .02 to 30 amps, select Current Code 630. For 35 - 50 amps, select Current Code 650. 1 Standard Hex Nut no For 55-70 amps, select Current Code 670. For 75-100 amps, select Current Code 810. A Standard Hex Nut (multi-pole units only) yes 3 Circuit Codes D,E,F,G,H & K available with Terminal Codes 1,2,4 & 5 only. 4 Consult factory for available Dual Coil options, as special catalog number is required. Dual Coil Voltage Coils with Shunt Trip Construction trip instantaneously on line voltage. Dual Coil Voltage Coils require 30VA minimum power to trip instantaneously and are 11 AGENCY APPROVAL rated for intermittent duty only. C UL Recognized, CSA Accepted 5 Auxiliary Switch available with Series Trip and Switch Only circuits. On multi-pole break- L UL Recognized, CSA Accepted with listed construction ers, one aux. switch is supplied, mounted in the extreme right pole. I UL Recognized, CSA Accepted, UL1500 ignition protection 6 Voltage coils not rated for continuous duty. Available only with delay codes 10 and 20. 7 Available with Circuit Codes B & D only, and up to 50 amps maximum. 8 Consult factory for current ratings 71-100, in three pole units, available as special catalog number only. 9 Terminal Code 1 available to 60 amps maximum. 10 Terminal Codes 2,4,5 and C available to 50 amps maximum. 11 Terminal Codes 3,6 & 9 available to 100 amps maximum. 12 Terminal Code 7 available to 25 amps maximum. 13 Terminal Code A available to 100 amps maximum. 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 Email: sales@carlingtech.com • www.carlingtech.com | C-Series Rocker UL Recognized – Ordering Scheme 11 C C 3 — B 0 — 14 — 450 — 1 2 1 — D 1 2 3 4 5 6 7 8 9 10 11 Terminal Actuator Mounting/ Agency Series Actuator Poles Circuit Aux/Alarm Frequency Current Rating Color Barriers Approval Switch & Delay 1 SERIES 7 CURRENT RATING (AMPERES) CODE AMPERES C 020 0.020 235 0.350 430 3.000 614 14.000 025 0.025 240 0.400 435 3.500 615 15.000 1 030 0.030 245 0.450 440 4.000 616 16.000 2 ACTUATOR Single color 035 0.035 250 0.500 445 4.500 617 17.000 Two Color Visi-Rocker J Vertical legend 040 0.040 255 0.550 450 5.000 618 18.000 C Indicate ON, vertical legend K Horizontal legend 045 0.045 260 0.600 455 5.500 620 20.000 D Indicate ON, horizontal legend L No legend 050 0.050 265 0.650 460 6.000 622 22.000 E Indicate ON, no legend Push-To-Reset, Single color 055 0.055 270 0.700 465 6.500 624 24.000 F Indicate OFF, vertical legend R Vertical legend 060 0.060 275 0.750 470 7.000 625 25.000 G Indicate OFF, horizontal legend U Horizontal legend 065 0.065 280 0.800 475 7.500 630 30.000 070 0.070 285 0.850 480 8.000 635 35.000 H Indicate OFF, no legend V No legend 075 0.075 290 0.900 485 8.500 640 40.000 Push-To-Reset, Visi-Rocker 080 0.080 295 0.950 490 9.000 650 50.000 N Indicate OFF, 9 085 0.085 410 1.000 495 9.500 660 60.000 vertical legend 9 090 0.090 512 1.250 610 10.000 670 70.000 O Indicate OFF, 9 095 0.095 415 1.500 710 10.500 680 80.000 horizontal legend 9 210 0.100 517 1.750 611 11.000 685 85.000 P Indicate OFF, 9 215 0.150 420 2.000 711 11.500 690 90.000 9 no legend 220 0.200 522 2.250 612 12.000 695 95.000 9 225 0.250 425 2.500 712 12.500 810 100.000 230 0.300 527 2.750 613 13.000 7 VOLTAGE COIL (NORMINAL RATED VOLTAGE) CODE RATING A06 6DC A32 32DC J12 12AC J65 65AC A12 12DC A48 48DC J18 18AC K20 120AC 2 3 POLES A18 18DC A65 65DC J24 24AC L40 240AC A24 24DC J06 6AC J48 48AC 1 One 2 Two 3 Three 4 8 TERMINAL 4 CIRCUIT F Relay Trip (Current) 10 13 3 4 1 Stud 10-32, threaded 7 0.250 Double Quick Connect A Switch Only (No Coil) G Relay Trip (Voltage) 11 2 Screw 10-32 8 1/4” Clip Terminal 4,5 B Series Trip (Current) H Dual Coil with Shunt Trip 12 3 Stud 1/4-20, threaded 9 7/16” Clip Terminal C Series Trip (Voltage) Voltage Coil 11 14 4 Stud M5 x 0.8, threaded A Plug-In Stud 4 4,5 D Shunt Trip (Current) K Dual Coil with Relay Trip 11 5 Screw M5 x 0.8 C 5/16” Clip Terminal 4 E Shunt Trip (Voltage) Voltage Coil 12 6 Stud M6, threaded 6 5 AUXILIARY/ALARM SWITCH 5 S.P.S.T., 0.110 Q.C. Term. 16,17,18 9 ACTUATOR COLOR & LEGEND 0 w/o Aux Switch (Gold Contacts) Actuator or 2 S.P.D.T., 0.110 Q.C. Term. 6 S.P.S.T., 0.139 Solder Lug Visi-Color Marking: Marking Color: 3 S.P.D.T., 0.139 Solder Lug 7 S.P.S.T., 0.110 Q.C. Term. Single Color 4 S.P.D.T., 0.110 Q.C. Term. (Gold Contacts) Color: I-O ON-OFF Dual/None Rocker/Handle Visi-Rocker (Gold Contacts) 8 S.P.S.T., 0.187 Q.C. Term. White A B 1 Black White 9 S.P.D.T., 0.187 Q.C. Term. Black C D 2 White n/a Red F G 3 White Red Green H J 4 White Green 6 FREQUENCY & DELAY 30 DC 50/60Hz Instantaneous Blue K L 5 White Blue 03 DC 50/60Hz, Switch Only 31 DC 50/60Hz Ultra Short 7 Yellow M N 6 Black Yellow 10 DC Instantaneous 32 DC 50/60Hz Short Gray P Q 7 Black Gray 11 DC Ultra Short 34 DC 50/60Hz Medium Orange R S 8 Black Orange 12 DC Short 36 DC 50/60Hz Long 8 14 DC Medium 42 50/60Hz Short, Hi-Inrush 8 16 DC Long 44 50/60Hz Medium, Hi-Inrush 7 8 1 20 50/60Hz Instantaneous 46 50/60Hz Long, Hi-Inrush 10 MOUNTING/BARRIERS 8 21 50/60Hz Ultra Short 52 DC Short, Hi-Inrush Standard Rocker Bezel BARRIERS 8 6-32 x 0.195 inches no 22 50/60Hz Short 54 DC Medium, Hi-Inrush 1 8 2 6-32 x 0.195 inches yes 24 50/60Hz Medium 56 DC Long, Hi-Inrush 19 6-32 x 0.195 inches yes 3 26 50/60Hz Long ISO M3 x 5mm no 4 Notes: ISO M3 x 5mm yes 5 1 Push-To-Reset actuators have OFF portion of rocker shrouded. 19 ISO M3 x 5mm yes 6 2 Multi-pole breakers have all poles identical except when specifying Aux. switch and/or mixed poles, and have one Rockerguard Bezel rocker per breaker. Rocker location as viewed from front panel: 2 pole – left pole; 3 pole – center pole. 6-32 x 0.195 inches no A 3 Switch Only circuits, rated up to 50 amps and 3 poles, and only available with VDE Certification when tied to a C 6-32 x 0.195 inches yes protected pole (Circuit Code B, C, D or H.), For .02 to 30 amps, select Current Code 630. For 35 - 50 amps, select 19 6-32 x 0.195 inches yes Current Code 650. For 55-70 amps, select Current Code 670. For 75-100 amps, select Current Code 810. E ISO M3 x 5mm no 4 Circuit Codes D,E,F,G,H & K available with Terminal Codes 1,2,4 & 5 only. Circuit Codes D,F,H & K available up G to 50 amps maximum Current Rating. J ISO M3 x 5mm yes 19 5 Consult factory for available Dual Coil options, as special catalog number is required. Dual Coil Voltage Coils ISO M3 x 5mm yes L with Shunt Trip Construction trip instantaneously on line voltage. Dual Coil Voltage Coils require 30VA minimum Push-To-Reset Bezel power to trip instantaneously and are rated for intermittent duty only. 6-32 x 0.195 inches no B Auxiliary Switch available with Series Trip and Switch Only circuits. On multi-pole breakers, one aux. switch is 6-32 x 0.195 inches yes D 6 supplied, mounted in the extreme right pole.Auxilary switch codes 2,3 & 4 are VDE approved. 19 6-32 x 0.195 inches yes F 7 Voltage coils not rated for continuous duty. Available only with delay codes 10 and 20. ISO M3 x 5mm no H 8 Available with Circuit Codes B & D only, and up to 50 amps maximum. J ISO M3 x 5mm yes 9 Current Ratings 60-70 are available up to four poles maximum. Ratings 71-100 are available up to two poles maximum. 19 ISO M3 x 5mm M yes 10 Terminal Code 1 available to 60 amps maximum. 11 Terminal Codes 2,4,5 & C available to 50 amps maximum. 12 Terminal Codes 3,6 & 9 available to 100 amps maximum. 13 Terminal Code 7 available to 25 amps maximum. 14 Terminal Code A available to 100 amps maximum. 11 AGENCY APPROVAL 15 Terminal Codes 7,8,9 & C are not VDE approved. C UL Recognized, CSA Accepted 16 Color shown is visi and legend with remainder of rocker black D VDE Certified, UL Recognized, CSA Accepted 17 Legend on Push-to-reset bezel/shroud is white when single color rocker is ordered. Dual = ON-OFF/I-O legend E TUV Certified, UL Recognized, CSA Accepted with actuator codes C - G, and J, K, N, O, R, & U. None = no legend with actuator codes H, L, P, V. Rocker- H UL489 Construction: VDE Certified, UL Recognized, CSA Accepted guard available with actuator codes C - L. Push-to-reset available witha ctuator codes N, O, P, R, U, V. I UL Rec. STD 1077, UL Rec. 1500 (ignition protected), CSA Accepted 18 VDE/TUV approval requires Dual (I-O, ON-OFF) or I-O markings on rocker. L UL489 Construction: UL Recognized, CSA Accepted 19 VDE/TUV: 30 amps max.; UL/CSA: 50 amps max.; Available in 2 - 4 poles only and limited to AC Delays. R UL489 Construction: TUV Certified, UL Recognized, CSA Accepted “General Purpose amps” not rated for “full load amps” or to be used in applications with a motor. 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 Email: sales@carlingtech.com • www.carlingtech.com Email: sales@carlingtech.com • www.carlingtech.com | 12 C-Series Handle UL Listed – Ordering Scheme C C 3 — B 0 — 14 — 450 — 1 2 A — K G 1 2 3 4 5 6 7 8 9 10 11 12 Terminal Actuator Mounting/ Max. App. Agency Series Actuator Poles Circuit Aux/Alarm Frequency Current Rating Color Barriers Rating Approval Switch & Delay 4 1 SERIES 7 CURRENT RATING (AMPERES) CODE AMPERES C 210 0.100 295 0.950 470 7.000 618 18.000 215 0.150 410 1.000 475 7.500 620 20.000 1 2 ACTUATOR 220 0.200 512 1.250 480 8.000 622 22.000 Two Color Visi-Rocker 225 0.250 415 1.500 485 8.500 624 24.000 C Indicate ON, vertical legend Single color 230 0.300 517 1.750 490 9.000 625 25.000 D Indicate ON, horizontal legend J Vertical legend 235 0.350 420 2.000 495 9.500 630 30.000 F Indicate OFF, vertical legend K Horizontal legend 240 0.400 522 2.250 610 10.000 635 35.000 G Indicate OFF, horizontal legend 245 0.450 425 2.500 710 10.500 640 40.000 250 0.500 527 2.750 611 11.000 650 50.000 ROCKER STYLE DESCRIPTIONS 255 0.550 430 3.000 711 11.500 660 60.000 INDICATE "ON" INDICATE "OFF" SINGLE COLOR 260 0.600 435 3.500 612 12.000 670 70.000 LINE CODE "C" CODE "F" CODE "J" 265 0.650 440 4.000 712 12.500 680 80.000 270 0.700 445 4.500 613 13.000 685 85.000 275 0.750 450 5.000 614 14.000 690 90.000 INDICATE COLOR 280 0.800 455 5.500 615 15.000 695 95.000 LINE LINE LOCATION 285 0.850 460 6.000 616 16.000 100 100.000 CODE "D" CODE "G" CODE "K" 290 0.900 465 6.500 617 17.000 LINE LINE LINE 8 TERMINAL 5 7 1 Stud 10-32, threaded 6 Stud M6, threaded 6 8 2 Screw 8-32 w/saddle & 8 1/4” Clip Terminal 1 3 POLES 7,8 washer clamps 9 7/16” Clip Terminal 1 One 2 Two 3 Three 7 7,8 3 Stud 1/4-20, threaded A Plug-In Stud 6 6,8 4 Stud M5 x 0.8, threaded C 5/16” Clip Terminal 6 5 Screw M5 x 0.8 w/saddle & 4 CIRCUIT washer clamps B Series Trip (current) 11 9 ACTUATOR COLOR & LEGEND 2 5 AUXILIARY/ALARM SWITCH 5 S.P.S.T., 0.110 Q.C. Term. Actuator or 0 w/o Aux Switch (Gold Contacts) Visi-Color 9 Marking: Marking Color: 2 S.P.D.T., 0.110 Q.C. Term. 6 S.P.S.T., 0.139 Solder Lug Single Color 3 S.P.D.T., 0.139 Solder Lug 7 S.P.S.T., 0.110 Q.C. Term. 10 Color: ON-OFF Dual Rocker/Handle Visi-Rocker 4 S.P.D.T., 0.110 Q.C. Term. (Gold Contacts) White B 1 Black White (Gold Contacts) 8 S.P.S.T., 0.187 Q.C. Term. Black D 2 White n/a 9 S.P.D.T., 0.187 Q.C. Term. Red G 3 White Red Green J 4 White Green Blue L 5 6 FREQUENCY & DELAY 26 50/60Hz Long White Blue 8 Yellow N 6 11 DC Ultra Short 42 50/60Hz Short, Hi-Inrush Black Yellow 8 Gray Q 7 12 DC Short 44 50/60Hz Medium, Hi-Inrush Black Gray 8 Orange S 8 14 DC Medium 46 50/60Hz Long, Hi-Inrush Black Orange 8 16 DC Long 52 DC Short, Hi-Inrush 8 21 50/60Hz Ultra Short 54 DC Medium, Hi-Inrush 12 22 50/60Hz Short 56 DC Long, Hi-Inrush 10 MOUNTING/BARRIERS 13 24 50/60Hz Medium Standard Rocker Bezel BARRIERS Threaded Insert, 2 per pole Notes: A 6-32 x 0.195 inches yes 1 Multi-pole breakers have all breakers identical except when specifying Aux. switch and/ C ISO M3 x 5mm yes or mixed poles, and have one rocker per breaker. Rockerguard Bezel 2 On multi-pole breakers, one aux. switch is supplied, mounted in the extreme right pole. Threaded Insert, 2 per pole 3 Available up to 50 amps maximum. B 6-32 x 0.195 inches yes 4 Current ratings 71 - 100 with VDE approvals are available up to two poles maximum. D ISO M3 x 5mm yes 5 Terminal Code 1 available to 60 amps maximum. 6 Terminal Codes 2, 4, 5 & C available to 50 amps maximum. 7 Terminal Codes 3, 6, 9 & A available to 100 amps maximum. 11 MAXIMUM APPLICATION RATING 8 Terminal Codes 8, 9 & C are not VDE approved. A 65 DC 9 Color shown is visi and legend with remainder of rocker black B 125 DC 10 Dual = ON-OFF/I-O legend on actuator. 14 C 120/240 AC 11 VDE and TUV approval requires Dual (I-O, ON-OFF) markings on rocker. D 240 AC 12 Rockerguard available with all actuator codes. K 120 AC 13 Barriers supplied on multi-pole units only. M 80 DC 14 2 & 3 pole circuit breakers required for 120/240 AC rating. 12 AGENCY APPROVAL A without approvals F UL 489 Listed, CSA Certified, & VDE Certified G UL 489 Listed & CSA Certified J UL489 Listed, CSA Certified & TUV Certified 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 Email: sales@carlingtech.com • www.carlingtech.com HORIZONTAL VERTICAL STYLE STYLE | C-Series Flat Rocker UL Recognized – Ordering Scheme 13 C 1 2 — B 0 — 10 — 450 — 1 2 1 — E 1 2 3 4 5 6 7 8 9 10 11 Terminal Actuator Mounting/ Agency Series Actuator Poles Circuit Aux/Alarm Frequency Current Rating Color Barriers Approval Switch & Delay 9 1 SERIES 7 CURRENT RATING (AMPERES) CODE AMPERES C 020 0.020 235 0.350 430 3.000 614 14.000 025 0.025 240 0.400 435 3.500 615 15.000 1 030 0.030 245 0.450 440 4.000 616 16.000 2 ACTUATOR 035 0.035 250 0.500 445 4.500 617 17.000 Two Color Visi-Rocker 040 0.040 255 0.550 450 5.000 618 18.000 1 Indicate OFF, vertical legend 045 0.045 260 0.600 455 5.500 620 20.000 2 Indicate OFF, horizontal legend 050 0.050 265 0.650 460 6.000 622 22.000 Single color 055 0.055 270 0.700 465 6.500 624 24.000 3 Vertical legend 060 0.060 275 0.750 470 7.000 625 25.000 4 Horizontal legend 065 0.065 280 0.800 475 7.500 630 30.000 070 0.070 285 0.850 480 8.000 635 35.000 Push-To-Reset, Visi-Rocker 075 0.075 290 0.900 485 8.500 640 40.000 5 Indicate OFF, vertical legend 080 0.080 295 0.950 490 9.000 650 50.000 6 Indicate OFF, horizontal legend 9 085 0.085 410 1.000 495 9.500 660 60.000 Push-To-Reset , Single color 9 090 0.090 512 1.250 610 10.000 670 70.000 7 Vertical legend 9 095 0.095 415 1.500 710 10.500 680 80.000 8 Horizontal legend 9 210 0.100 517 1.750 611 11.000 685 85.000 9 215 0.150 420 2.000 711 11.500 690 90.000 9 220 0.200 522 2.250 612 12.000 695 95.000 2 9 3 POLES 225 0.250 425 2.500 712 12.500 810 100.000 230 0.300 527 2.750 613 13.000 1 One 2 Two 3 Three 7 VOLTAGE COIL (NORMINAL RATED VOLTAGE) CODE RATING 4 4 CIRCUIT F Relay Trip (Current) A06 6DC A32 32DC J12 12AC J65 65AC 3 4 A12 12DC A48 48DC J18 18AC K20 120AC A Switch Only (No Coil) G Relay Trip (Voltage) 4,5 A18 18DC A65 65DC J24 24AC L40 240AC B Series Trip (Current) H Dual Coil with Shunt Trip A24 24DC J06 6AC J48 48AC C Series Trip (Voltage) Voltage Coil 4 4,5 D Shunt Trip (Current) K Dual Coil with Relay Trip 4 E Shunt Trip (Voltage) Voltage Coil 12 8 TERMINAL 6 Stud M6, threaded 10 13 1 Stud 10-32, threaded 7 0.250 Double Quick Connect 11 2 Screw 10-32 8 1/4” Clip Terminal 6 5 AUXILIARY/ALARM SWITCH 5 S.P.S.T., 0.110 Q.C. Term. 12 3 Stud 1/4-20, threaded 9 7/16” Clip Terminal 11 14 0 w/o Aux Switch (Gold Contacts) 4 Stud M5 x 0.8, threaded A Plug-In Stud 11 2 S.P.D.T., 0.110 Q.C. Term. 6 S.P.S.T., 0.139 Solder Lug 5 Screw M5 x 0.8 C 5/16” Clip Terminal 3 S.P.D.T., 0.139 Solder Lug 7 S.P.S.T., 0.110 Q.C. Term. 4 S.P.D.T., 0.110 Q.C. Term. (Gold Contacts) (Gold Contacts) 8 S.P.S.T., 0.187 Q.C. Term. 16,17,18 9 ACTUATOR COLOR & LEGEND 9 S.P.D.T., 0.187 Q.C. Term. Actuator or Visi-Color Marking: Marking Color: 6 FREQUENCY & DELAY 30 DC 50/60Hz Instantaneous Single Color 03 DC 50/60Hz, Switch Only 31 DC 50/60Hz Ultra Short Color: I-O ON-OFF Dual/None Rocker/Handle Visi-Rocker 7 10 DC Instantaneous 32 DC 50/60Hz Short White A B 1 Black White 11 DC Ultra Short 34 DC 50/60Hz Medium Black C D 2 White n/a 12 DC Short 36 DC 50/60Hz Long Red F G 3 White Red 8 14 DC Medium 42 50/60Hz Short, Hi-Inrush Green H J 4 White Green 8 16 DC Long 44 50/60Hz Medium, Hi-Inrush Blue K L 5 White Blue 7 8 20 50/60Hz Instantaneous 46 50/60Hz Long, Hi-Inrush Yellow M N 6 Black Yellow 8 21 50/60Hz Ultra Short 52 DC Short, Hi-Inrush Gray P Q 7 Black Gray 8 22 50/60Hz Short 54 DC Medium, Hi-Inrush Orange R S 8 Black Orange 8 24 50/60Hz Medium 56 DC Long, Hi-Inrush 26 50/60Hz Long 1` 10 MOUNTING/BARRIERS Notes: Standard Rocker Bezel BARRIERS VOLTAGE 1 Push-to-reset actuators have OFF portion of rocker shrouded. 6-32 x 0.195 inches no < 300 1 2 Multi-pole breakers have all poles identical except when specifying Aux. switch and/or mixed poles, and have 6-32 x 0.195 inches yes < 2 300 one rocker per breaker. Rocker location as viewed from front panel: 2 pole – left pole; 3 pole – center pole. 19 > 6-32 x 0.195 inches yes 300 3 Switch Only circuits, rated up to 50 amps and 3 poles, and only available with VDE Certification when tied to a 3 – < protected pole (Circuit Code B, C, D or H.). For .02 to 30 amps, select Current Code 630. For 35 - 50 amps, ISO M3 x 5mm no 300 4 select Current Code 650. For 55-70 amps, select Current Code 670. For 75-100 amps, select Current Code 810. ISO M3 x 5mm yes 300 < 5 19 4 Circuit Codes D,E,F,G,H & K available with Terminal Codes 1,2,4 & 5 only. Circuit Codes D,F,H & K available up > 6 ISO M3 x 5mm yes 300 – to 50 amps maximum Current Rating. Rockerguard Bezel 5 Consult factory for available Dual Coil options, as special catalog number is required. Dual Coil Voltage Coils 6-32 x 0.195 inches no < 300 7 with Shunt Trip Construction trip instantaneously on line voltage. Dual Coil Voltage Coils require 30VA minimum < 8 6-32 x 0.195 inches yes 300 power to trip instantaneously and are rated for intermittent duty only. > 6-32 x 0.195 inches yes 300 9 – 6 Auxiliary Switch available with Series Trip and Switch Only circuits. On multi-pole breakers, one aux. switch is < ISO M3 x 5mm no 300 A supplied, mounted in the extreme right pole.Auxilary switch codes 2,3 & 4 are VDE approved. ISO M3 x 5mm yes < C 300 7 Voltage coils not rated for continuous duty. Available only with delay codes 10 and 20. > ISO M3 x 5mm yes 300 8 Available with Circuit Codes B & D only, and up to 50 amps maximum. E – Push-To-Reset Bezel 9 Current ratings 60-70 are available up to four poles maximum. Current ratings 71 - 100 are available up to two 6-32 x 0.195 inches no < 300 poles maximum. B < 10 Terminal Code 1 available to 60 amps maximum. D 6-32 x 0.195 inches yes 300 19 > 11 Terminal Codes 2,4,5 & C available to 50 amps maximum. 6-32 x 0.195 inches yes 300 F – 12 Terminal Codes 3,6 & 9 available to 100 amps maximum. < ISO M3 x 5mm no 300 H 13 Terminal Code 7 available to 25 amps maximum. < J ISO M3 x 5mm yes 300 14 Terminal Code A available to 100 amps maximum. 19 > ISO M3 x 5mm yes 300 M – 15 Terminal Codes 7,8,9 & C are not VDE approved. 16 Color shown is visi & legend with remainder of rocker black. Dual = ON-OFF/I-O legend. 17 Legend on Push-to-reset bezel/shroud is white with single color actuator codes 7 & 8. Legend on Push-to-reset bezel/shroud matches visi-color of rocker with actuator codes 5 & 6. 11 AGENCY APPROVAL 18 VDE/TUV approval requires Dual (I-O, ON-OFF) or I-O markings on rocker. C UL Recognized, CSA Accepted 19 VDE/TUV: 30 amps max.; UL/CSA: 50 amps max.; Available in 2 & 3 poles only and limited to AC Delays. E TUV Certified, UL Recognized, CSA Accepted “General Purpose amps” not rated for “full load amps” or to be used in applications with a motor. I UL Rec. STD 1077, UL Rec. 1500 (ignition protected), CSA Accepted 20 Recessed “OFF SIDE” available with actuator codes 1,2,3&4. Legends on rocker are available in ink stamping only. L UL489 Construction: UL Recognized, CSA Accepted R UL489 Construction: TUV Certified, UL Recognized, CSA Accepted 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 Email: sales@carlingtech.com • www.carlingtech.com Email: sales@carlingtech.com • www.carlingtech.com | 14 C-Series Handle Flat Rocker UL Listed – Ordering Scheme C 1 2 — B 0 — 14 — 450 — 1 2 A — K G 1 2 3 4 5 6 7 8 9 10 11 12 Terminal Actuator Mounting/ Max. App. Agency Series Actuator Poles Circuit Aux/Alarm Frequency Current Rating Color Barriers Rating Approval Switch & Delay 5 1 SERIES 7 CURRENT RATING (AMPERES) CODE AMPERES C 210 0.100 295 0.950 470 7.000 618 18.000 215 0.150 410 1.000 475 7.500 620 20.000 1 2 ACTUATOR 220 0.200 512 1.250 480 8.000 622 22.000 Two Color Visi-Rocker 225 0.250 415 1.500 485 8.500 624 24.000 1 Indicate OFF, vertical legend 230 0.300 517 1.750 490 9.000 625 25.000 2 Indicate OFF, horizontal legend 235 0.350 420 2.000 495 9.500 630 30.000 Single color 240 0.400 522 2.250 610 10.000 635 35.000 3 Vertical legend 245 0.450 425 2.500 710 10.500 640 40.000 4 Horizontal legend 250 0.500 527 2.750 611 11.000 650 50.000 Push-To-Reset, Visi-Rocker 255 0.550 430 3.000 711 11.500 660 60.000 5 Indicate OFF, vertical legend 260 0.600 435 3.500 612 12.000 670 70.000 6 Indicate OFF, horizontal legend 265 0.650 440 4.000 712 12.500 680 80.000 Push-To-Reset , Single color 270 0.700 445 4.500 613 13.000 685 85.000 7 Vertical legend 275 0.750 450 5.000 614 14.000 690 90.000 8 Horizontal legend 280 0.800 455 5.500 615 15.000 695 95.000 285 0.850 460 6.000 616 16.000 100 100.000 290 0.900 465 6.500 617 17.000 2 3 POLES 1 One 2 Two 3 Three 8 TERMINAL 6 8 1 Stud 10-32, threaded .625 long 6 Stud M6, threaded 17mm long 7 9 4 CIRCUIT 2 Screw 8-32 w/saddle & 8 1/4” Clip Terminal 8,9 B Series Trip (current) washer clamps 9 7/16” Clip Terminal 8 8,9 3 Stud 1/4-20, threaded .625 long A Plug-In Stud 7 7,9 4 Stud M5 x 0.8, threaded .625 long C 5/16” Clip Terminal 2 7 5 AUXILIARY/ALARM SWITCH 5 S.P.S.T., 0.110 Q.C. Term. 5 Screw M5 x 0.8 w/saddle & 0 w/o Aux Switch (Gold Contacts) washer clamps 2 S.P.D.T., 0.110 Q.C. Term. 6 S.P.S.T., 0.139 Solder Lug 3 S.P.D.T., 0.139 Solder Lug 7 S.P.S.T., 0.110 Q.C. Term. 12 4 S.P.D.T., 0.110 Q.C. Term. (Gold Contacts) 9 ACTUATOR COLOR & LEGEND (Gold Contacts) 8 S.P.S.T., 0.187 Q.C. Term. Actuator or 9 S.P.D.T., 0.187 Q.C. Term. Visi-Color 9 Marking: Marking Color: Single Color 11 Color: ON-OFF Dual Rocker/Handle Visi-Rocker 6 FREQUENCY & DELAY White B 1 Black White 11 DC Ultra Short 26 50/60Hz Long 4 Black D 2 White n/a 12 DC Short 42 50/60Hz Short, Hi-Inrush 4 Red G 3 White Red 14 DC Medium 44 50/60Hz Medium, Hi-Inrush 4 Green J 4 White Green 16 DC Long 46 50/60Hz Long, Hi-Inrush 4 Blue L 5 White Blue 21 50/60Hz Ultra Short 52 DC Short, Hi-Inrush 4 Yellow N 6 Black Yellow 22 50/60Hz Short 54 DC Medium, Hi-Inrush 4 Gray Q 7 Black Gray 24 50/60Hz Medium 56 DC Long, Hi-Inrush Orange S 8 Black Orange Notes: 1 Push-to-reset actuators have OFF portion of rocker shrouded. 12 10 MOUNTING/BARRIERS 2 Multi-pole breakers have all breakers identical except when specifying Aux. switch and/ 15 Standard Rocker Bezel BARRIERS or mixed poles, and have one rocker per breaker. Threaded Insert, 2 per pole 3 On multi-pole breakers, one aux. switch is supplied, mounted in the extreme right pole. A 6-32 x 0.195 inches yes 4 Available up to 50 amps maximum. C ISO M3 x 5mm yes 5 Current ratings 71 - 100 with VDE approvals are available up to two poles maximum. 14 Recessed Off Rocker 6 Terminal Code 1 available to 60 amps maximum. Threaded Insert, 2 per pole 7 Terminal Codes 2, 4, 5 & C available to 50 amps maximum. E 6-32 x 0.195 inches yes 8 Terminal Codes 3, 6, 9 & A available to 100 amps maximum. F ISO M3 x 5mm yes 9 Terminal Codes 8, 9 & C are not VDE approved. Push-To-Reset Bezel 10 Color shown is visi and legend with remainder of rocker black Threaded Insert, 2 per pole 11 Dual = ON-OFF/I-O legend on actuator. B 6-32 x 0.195 inches yes 12 VDE and TUV approval requires Dual (I-O, ON-OFF) markings on rocker. D ISO M3 x 5mm yes 13 Legend on push-to-reset bezel/shroud is white when single color rocker is ordered. Legend on push-to-reset bezel/shroud matches visi-color of rocker with actuator codes 5 & 6. 11 MAXIMUM APPLICATION RATING 14 Recessed “OFF-SIDE” available with actuator codes 1, 2, 3, & 4. Legends on rocker are A 65 DC available in ink stamping only. B 125 DC 15 Barriers supplied on multi-pole units only. 16 C 120/240 AC 16 2 & 3 pole circuit breakers required for 120/240 AC rating. D 240 AC K 120 AC M 80 DC 12 AGENCY APPROVAL A without approvals G UL 489 Listed & CSA Certified J UL489 Listed, CSA Certified & TUV Certified 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 Email: sales@carlingtech.com • www.carlingtech.com | C-Series Handle – Circuit & Terminal Diagrams 15 LINE LOAD Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 3 Available on Series Trip and Switch Only Circuits when called for on multi-pole units. Only one aux. switch is normally supplied, as viewed in mulit-pole identification scheme. 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 Email: sales@carlingtech.com • www.carlingtech.com Email: sales@carlingtech.com • www.carlingtech.com | 16 C-Series Handle – Circuit & Terminal Diagrams LINE LOAD Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 3 Schematic shown represents current trip circuits. 4 Available only as special catalog number. 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 Email: sales@carlingtech.com • www.carlingtech.com C-Series Handle – Form & Fit Drawings | 17 LINE LOAD Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 Email: sales@carlingtech.com • www.carlingtech.com Email: sales@carlingtech.com • www.carlingtech.com | 18 C-Series Handleguard – Form & Fit Drawings LINE LOAD Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 Email: sales@carlingtech.com • www.carlingtech.com | C-Series Parellel Pole – Form & Fit Drawings 19 LINE LOAD Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 Email: sales@carlingtech.com • www.carlingtech.com Email: sales@carlingtech.com • www.carlingtech.com | 20 C-Series Sealed Toggle – Form & Fit Drawings LINE LOAD Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 Email: sales@carlingtech.com • www.carlingtech.com | C-Series Rocker – Circuit & Terminal Diagrams 21 LINE LOAD Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 3 Schematic shown represents current trip circuit. 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 Email: sales@carlingtech.com • www.carlingtech.com Email: sales@carlingtech.com • www.carlingtech.com | 22 C-Series Rocker – Form & Fit Drawings LINE LOAD Notes: 1 Dimensions apply to all variations shown. Notice that circuit breaker line and load terminal orientation on indicate OFF is opposite of indicate ON. 2 For pole orientation with horizontal legend, rotate front view clockwise 90°. 3 All dimensions are in inches [millimeters]. 4 Tolerance ±.020 [.51] unless otherwise specified. 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 Email: sales@carlingtech.com • www.carlingtech.com | C-Series Flat Rocker – Form & Fit Drawings 23 LINE LOAD Notes: 1 For pole orientation with horizontal legend, rotate front view clockwise 90°. 2 All dimensions are in inches [millimeters]. 3 Tolerance ±.020 [.51] unless otherwise specified. 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 Email: sales@carlingtech.com • www.carlingtech.com Email: sales@carlingtech.com • www.carlingtech.com Worldwide Headquarters Carling Technologies, Inc. 60 Johnson Avenue • Plainville, CT 06062-1177 Phone: (860) 793-9281 • Fax: (860) 793-9231 Email: sales@carlingtech.com • www.carlingtech.com East Region Sales Office, CT • ersm@carlingtech.com Midwest Region Sales Office, IL • mrsm@carlingtech.com West Region Sales Office, CA • wrsm@carlingtech.com Asia-Pacific Headquarters Carling Technologies, Asia-Pacific Ltd., Kowloon, Hong Kong Int + 852-2737-2277 • Fax: Int + 852-2736-9332 Email: sales@carlingtech.com.hk Shenzhen, China • shenzhen@carlingtech.com Shanghai, China • shanghai@carlingtech.com Pune, India • india@carlingtech.com Kaohsiung, Taiwan • taiwan@carlingtech.com Yokohama, Japan • japan@carlingtech.com Europe/Middle East/Africa Headquarters Carling Technologies, Ltd., Devon, England 06062-1177 Int + 44 1392-364422 • Fax: Int + 44 1392-364477 Email: ltd.sales@carlingtech.com GmbH, Germany • gmbh@carlingtech.com SAS, France • sas@carlingtech.com REV_CB_C_0312

Frequently asked questions

What makes Elite.Parts unique?

chervon down
At GID Industrial (Elite.Parts' parent company), we specialize in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

What kind of warranty will the CF1-B0-14-810-33D-MG have?

chervon down
Warranties differ by part and by which suppliers we use to procure it for you. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carriers does Elite.Parts work with?

chervon down
Elite.Parts can ship via FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Will Elite.Parts sell to me even though I live outside the USA?

chervon down
Absolutely! We are happy to serve customers regardless of location. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

I have a preferred payment method. Will Elite.Parts accept it?

chervon down
All major credit cards are accepted: Visa, MasterCard, Discover, and American Express. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

Circuit Breaker, Visi-Rocker, Vertical Legends, 5 Amps

Circuit Breaker, Visi-Rocker, Vertical Legends, 10 Amps

Circuit Breaker, Visi-Rocker, Vertical Legends, 15 Amps

Circuit Breaker, Visi-Rocker, Vetical Legends, 20 Amps

Circuit Breaker, Visi-Rocker, 2 Pole, Vertical Legends, 10 Amps

Circuit Breaker, Visi-Rocker, 2 Pole, 15 Amps