California Instruments 4500LX 4.5 kVA AC Source w/ RS-232/USB & GPIB

Part Number

4500LX

Price

Request Quote

Manufacturer

CALIFORNIA INSTRUMENTS

Lead Time

Request Quote

Category

PRODUCTS - 4

Features

Datasheet

pdf file

California Instruments-4500LX-datasheet1-1623902339.pdf

458 KiB

Extracted Text

California Instruments Lx Series 3000–18000 VA 135–400 V 3-18 kVA Programmable AC and DC Power Source / Analyzer • Backward Compatible 0–132 A Compatible with HP6834B & iL Series AC Sources Function & bus compatible with the Agilent HP6834B & California Instruments iL Series 208 230 400 • Three phase and Single phase modes Ideally suited for avionics and defense applications 230 • 3 kVA to 18 kVA Power Levels Match power source and cost to application requirements • Arbitrary Waveform Generator Test products for harmonics susceptibility • Built-in Power Analyzer Performs voltage and load current harmonic changes with quick sweeps through the entire analysis and waveform acquisition range. A keypad makes precise entries simple. • Standard IEEE-488, USB & RS232 Applications Remote control interface for ATE With precise output regulation and accuracy, system integration included high load drive current, multi or single phase mode and built-in power analyzer measurement Integrated System capabilities, Lx Series AC source/analyzers address The Lx Series represents a modern AC power many application areas for AC power testing. source that addresses increasing demands on test Additional features, like line arbitrary waveform equipment to perform more functions at a lower generation and available DO 160, MIL 704, or cost. By combining a flexible AC power source Airbus test standards, make the Lx Series a good with a harmonic power analyzer, the Lx Series choice for avionics or defense applications. All systems are capable of handling applications Lx Series AC sources are equipped with IEEE- that would traditionally have required multiple 488 (GPIB), USB and RS232C remote control instruments. interfaces and support SCPI command language programming. An ethernet interface option is The sleek integrated approach of the Lx Series available. avoids the cable clutter that is commonly found in AC test setups. All connections are made HP6834B Compatibility internally and the need for external digital The Lx Series offers functional and bus multimeters, power harmonics analyzer and compatibility with the Agilent HP6834B AC current shunts is completely eliminated. power sources as well as the CI iL Series AC power sources and may be used in existing test Using a state of the art Digital Signal Processor in systems without the need to modify program conjunction with precision A/D converters, the Lx code. Series provides more accuracy and resolution than can be found in most dedicated harmonic power Standard Waveforms analyzers. Since many components in the Lx The Lx Series provides three standard waveforms Series are shared between the AC source and the that are always available for output. The standard power analyzer, the total cost of the integrated waveforms are: system is less than the typical cost of a multiple • Sinewave for normal AC applications. unit system. • Squarewave for special applications. Easy To Use Controls • Clipped Sinewave - Simulates THD leveLx to test Distributed by: The Lx Series is completely microprocessor www.SignalTestInc.com for harmonic distortion susceptibility. controlled and can be operated from a simple 1529 Santiago Ridge Way In addition to these standard waveforms, user San Diego, CA 92154 USA. front panel keypad. An analog control located defined waveform can be downloaded over the Sales@SignalTestInc.com next to the backlit alphanumeric LCD display bus. allows output voltage and frequency to be slewed up or down dynamically. The control employs a dynamic rate change algorithm that combines the benefits of precise control over small parameter sales@ProgrammablePower.com 191 858.458.0223 Lx Series Lx Series - AC Transient Generation Harmonic Waveform Generation Using the latest DSP (Digital Signal Processing) technology, the Lx Series controller is capable of generating harmonic waveforms to test for harmonics susceptibility of a unit under test. With the help of the supplied Windows Graphical User Interface program, defining harmonic waveforms is as easy as specifying the relative amplitude and phase angle for each of up to 50 harmonics. The waveform data points are generated and downloaded by the GUI to the AC source through either IEEE-488 or RS232C bus and remain in non-volatile memory. Up to twelve waveforms Harmonic waveform, Fund., 3rd, 5th, 7th and 9th. can be stored and given a user defined name for easy recall. Arbitrary Waveform Generation Using the provided GUI program or custom software, the user also has the ability to define arbitrary waveform data. Complex AC voltage anomalies can be simulated this way. The GUI program provides a catalog of custom waveforms and also allows real-world waveforms captured on a digital oscilloscope to be downloaded to one of the AC source’s waveform memories. Downloaded waveforms are retained in non- volatile memory for recall over the bus or from the front panel. User defined waveform names Simulation of severe ringing on the output of a UPS. make it easy to recall the desired waveform when needed. Lx Series - Configuration Options Transient Programming To simulate common line disturbance occurrences, the Lx Series offers a list of transient steps. These steps can be programmed from the front panel or downloaded over the interface using the GUI program supplied. The GUI allows libraries of commonly used line disturbances to be created on disk for quick recall. Once downloaded, the transient program can be executed from the PC or from the front panel. AC transient generation allows the effect of rapid changes in voltage, frequency, phase angle and waveform shape on the unit under test to be Voltage sweep transient causes output voltage to change at analyzed. The combination of transients and user a programmed rate. defined arbitrary waveforms creates a powerful test platform for AC powered products. Lx Series - Measurement and Analysis Standard Measurements The Lx Series measurement system is based The following standard measurements are on real-time digitization of the voltage and available from the front panel or via the bus: current waveforms using a 4K sample buffer. • Frequency and Phase The digitized waveform data is processed by a • Voltage (rms) Digital Signal Processor to extract conventional • Current(rms) and Peak Current load values such as rms voltage, rms current, real • Crest Factor and apparent power. The same data is also used • Neutral Current (rms) to perform Fast Fourrier Transformation (FFT) to • Real Power and Apparent Power extract the harmonic amplitude and phase angle • Power Factor of up to 50 harmonics. 192 www.ProgrammablePower.com Lx Series 3000–18000 VA Advanced Measurement Functions In addition to standard load parameters, the Lx Series is capable of measuring voltage and current amplitude and phase harmonics up to the 50th harmonic (for fundamental frequencies up to 250 Hz). Total harmonic distortion of both voltage and current is also available. Harmonic analysis data can be displayed on the front panel display or on the PC using the GUI program. The GUI can also be used to save and print harmonics data in tabular, bar graph or time domain formats. The acquired voltage and current time- domain waveforms for each output phase can be displayed using the GUI program. Waveform Standard measurements for all phases. displays on the PC include voltage and current combined, three phase voltage, three phase current and true power. The time-domain data is aLxo available for transferr to a PC through IEEE- 488, USB, RS232C, or Ethernet (option) when using custom software. Diagnostics Capability The AC Source can perform a self test and report any errors. The self test will run until the first error is encountered and terminate. The response to the self test query command will either be the first error encountered or 0 if no error was found. (Self test passed). Windows Instrument Control Software A Windows Vista/2000/XP™ compatible Relative Current Harmonics shown in table and chart. Instrument Control Software (GUI) offers a soft front panel interface for operation from a PC. The following functions are available: • Steady state output control (all parameters). • Create, run, save and print transient programs. • Generate and save harmonic waveforms. • Generate and save arbitrary waveforms. • Download data from a digital storage oscilloscope. • Measure and log standard measurements. • Capture and display Voltage and Current waveforms. • Measure, display, print and log harmonic voltage and current measurements. Soft front panel control through Windows GUI. Constant Power AC Mode - Available Max. AC Current 125% 100% Full Power 50% 20% 50% 10% 80% 100% sales@ProgrammablePower.com 193 858.458.0223 Lx Series Output Maximum Power per phase 3000Lx: 1 phase: 3000 VA, 3 phase: 1000 VA; 4500Lx: 1 phase 4500 VA, 3 phase 1500 VA; 6000Lx: 1 phase 5770 VA, 3 phase: 1923 VA Power factor 0 to unity at full output VA Voltage Ranges Range V Low V High VA Programming Resolution 100 mV AC 0-150V 0-300V Load Regulation < 0.1 % FS Line Regulation < 0.02 % for 10 % line change See -HV and EHV options for alternative voltage range pairs. Programming Accuracy (25°C ±5°C Voltage (rms): ± (0.05% + 0.25) V from 5.0 V to FS; Frequency: ± 0.025 45 Hz - 819.1 Hz, ± 0.7 % > 819.1 Hz; Phase: ± 1° 45-100 Hz, ± (1° + 1°/kHz) 100 Hz-1kHz Frequency Range 17 Hz - 1000 Hz (see -HF option for higher output frequencies) Frequency Resolution 0.01 Hz at < 81.9 Hz, 0.1 Hz at 82.0 to 819.1 Hz, 1 Hz at > 819 Hz Max RMS Current V Range V high V low < At Full Power Model 3000Lx-3 Ø 3000Lx-1 Ø 4500Lx-3 Ø 4500Lx-1 Ø 6000Lx-3 Ø 6000Lx-1 Ø -3 3 ø 6..4 A 12.8 A V Low At FS Voltage > 6.6 A 20.0 A 10.0 A 30.0 A 19.2 A 38.4 A -1 1 ø 19.2 A 38.4 A V High 3.3 A 10.0 A 5.0 A 15.0 A 6.4 A 12.8 A Note: Constant power mode on 3000Ls and 4500Ls provides increased current at reduced voltage; 6000Ls provides maximum voltage. Current Limit Programmable from 0 Amps to maximum current for selected range Peak Current 3000Lx: 5.7 X (lrms @ full scale voltage); 4500Lx: 3.8 X (lrms @ full scale voltage); 6000Lx: 3 X (lrms @ full scale voltage) Output Noise 100mV rms typ. (20 kHz to 1 MHz) Harmonic Distortion < 1% (at full scale voltage, full resistive load) Isolation Voltage 300 V rms output to chassis Output Relay Push button controlled and bus controlled output relay Input Voltage ModeLx 3000Lx, 4500Lx, 9000Lx, 13500Lx: Standard: 208-230 ± 10% VAC, (L-L, 3 Phase); Option -400: 400 ± 10% VAC (L-L, 3 Phase); ModeLx 6000Lx, 12000Lx, 18000Lx: Standard 208-230 + 10% VAC (L-L, 3 Phase) Notes: 1. Input must be specified when ordering. 2. -400 option not availble on 6000Lx, 12000Lx, 18000Lx. 3. 3000Lx can be operated from 1 phase AC. Line Current (rms per phase) Model 3000Lx 3000Lx (1Phase) 4500Lx 6000Lx (@ 208V) Inrush Current @ 180-254 V: 50 A peak (Per phase): @ 360-440 V: 83 A peak 187 VLL 19 A 32 A 31 A 38 A 360 VLL 10 A n/a 16 A n/a Line Frequency: 47-440 Hz 75% typical Efficiency Power Factor 0.6 typical Hold-up Time At least 10 ms System Storage Setup: 16 complete instrument setups / Transient List: 100 transient steps per list (SCPI mode) or 16 transient registers (APE mode) Trigger Input/Output Input: Triggers measurements or transient steps - SMA connector: 10K pull-up / Output: SMA Connector: HCTTL output Protection Overload/Temp/Voltage Overload: Constant current or constant voltage mode; Over temperature: Automatic Shutdown; Over voltage: Automatic shutdown Regulatory/RFI Suppresion IEC1010, EN50081-2, EN50082-2, CE, EMC, and safety mark requirements / RIF Suppression: CISPR 11, Group1, Class A Measurement Measurements - Standard Parameter Frequency Phase Voltage (AC) Current (AC rms) Real Power Apparent Power Power Factor (AC Measurements) Range 45-81.91 Hz 45-100 Hz 0-300 V 0-50 A 0-6 kW 0-6 kVA 0.00-1.00 82.0-819.1 Hz 100-1000 Hz > 819 Hz Accuracy* (±) 1 ø mode (-1) 0.1% + 1 digit 0.5° 0.5% + 250 mV 0.1% + 150 mA 0.15% + 9 W 0.15% + 9 VA 0.03 3 ø mode (-3) 2° 0.1% + 50 mA 0.15% + 3 W 0.15% + 3 VA 0.01 Resolution* .01 Hz / 0.1 Hz / 1 Hz 0.1° / 1° 10 mV 1 mA 1 W 1 VA 0.01 * Accuracy specifications are in % of reading and apply above 100 counts. For multi-chassis configurations, current, power range and accuracy specifications are times three. Power factor accuracy applies for PF > 0.5 and VA > 50% of max. Frequency measurement specification valid for output > 30 Vrms. Note: Specifications are subject to change without notice. Specifications are warranted over an ambient temperature range of 25°± 5° C. Unless otherwise noted, specifications are per phase for a sinewave with a resistive load and apply after a 30 minute warm-up period. For three phase configurations, all specifications are for L-N. Phase angle specifica- tions are valid under balanced load conditions only. 194 www.ProgrammablePower.com Lx Series 3000–18000 VA Remote Control IEEE-488 Interface (option) IEEE-488 (GPIB) talker listener. Subset: AH1, C0, DC1, DT1, L3, PP0, RL2, SH1, SR1, T6, IEEE-488.2 SCPI Syntax USB Interface & Ethernet Version: USB 1.1; Speed: 460 Kb/s maximum / Ethernet Interface (Optional): specify -LAN option. 10BaseT, 100BaseT, RJ45 RS232C Interface Bi-directional serial interface; 9-pin D-shell connector. Handshake: CTS, RTS. Databits: 7 w/ parity, 8 w/o parity. Stopbits: 2. Baud rate: 9600 to 115200. Supplied with RS232C cable / Code and Format: SCPI; APE (option -GPIB) Physical Dimensions Dimensions (per chassis) Height: 10.5” (267 mm), Width: 19” (483 mm), Depth: 23.7” (602 mm) (depth includes rear panel connectors) Weight Chassis: Net: 193 lbs / 87.7 Kg, Shipping: 280 lbs / 127.3 Kg (for /2 or /3 model configuarations multiply number of chassis). Vibration and Shock Designed to meet NSTA project 1A transportation leveLx Air Intake/Exhaust Forced air cooling, side air intake, rear exhaust Temperature & Diagnostics Temperature: Operating: 0 to 35° C, full power / Storage: -40 to +85° C; Diagnostics: Built-in self test available over bus (*TST) Rear Panel Connectors *Three phase AC input and output terminal block with safety cover. *IEEE-488 (GPIB) connector, USB connector, RJ45 connector (with -LAN Option). *9-pin D-Shell RS232C connector (RS232 DB9 to DB9 cable supplied). *Remote Inhibit (INH) and Discrete Fault Indicator (DFI). *Remote voltage sense terminal block. *Trigger In1 and Trigger Out1. *System interface connectors. *Auxilary Output (Option -AX) Option -AX Specifications Option -AX Provides seperate isolated 26 VAC regulated and 5 Vac unregulated outputs. The 26 V is normally used for servo-synchro excitation, and the 5 V for lamp power. 26 Volt-Accuracy: ± 2%. Current capacity: 3 ARMS. Frequency: 360/440 Hz. Regulation ± 0.05%. 5 Volt-Accuracy: ± 5%. Current capacity: 5 ARMS Option -ADV Specifications Measurements - Harmonics Parameter Frequency Fundamental Harmonics Voltage Current Range 45-250 Hz / 0.09 - 12.5 kHz Fundamental Harmonics 2 - 50 Fundamental Harmonics 2 - 50 Accuracy* (±) 0.01% + 1 digit / 0.5% + 1 digit 750 mV 0.3% + 750 mV+0.3% /1 kHz 0.5 A / 0.3% + 150 mA +0.3% /1 kHz Resolution 0.01 Hz / 0.1 Hz 10 mV / 10 mV 10 mA / 10 mA * Accuracy specifications are in a percent of reading for single unit in 3-phase mode. Waveforms Pre defined: Sine, Square, Clipped User defined, 1024 addressable data points; Storage: 50 user waveforms, non-volatile memory Data Acquisition Parameters: Voltage, Current time domain, per phase; Resolution: 4096 data points, 10.4 usec (1ø) or 31.25 usec (3ø) sampling interval Option -HV Specifications Voltage/Frequency Ranges Low: 0-135 Volt; High: 0-270 Volt / Frequency: With -HF option: 3000Lx, 4500Lx, 6000Lx: 45 Hz - 5000 Hz; 9000Lx, 12000Lx, 13500Lx, 18000Lx: 45 Hz - 5000 Hz Max RMS Current at Full Power 3 Phase: High: 7.4 A, Low 14.8 A; 1 Phase: High: 22.2 A, Low: 44.4 A; Note: Constant power modes on 3000Lx and 4500Lx. Current available at reduced voltage for 3000Lx, 4500Lx, and max voltage for 6000Lx Max RMS Current at FSVoltage 3000Lx: 3 Phase: High: 3.7 A, Low: 7.4 A; 1 Phase: High 11.1 A, Low: 22.2 A; 4500Lx: 3 Phase: High: 5.6, Low 11.1; 1 Phase: High: 16.7 A, Low: 33.3 A; 6000Lx: 3 Phase: High: 7.4 A, Low 14.8 A; 1 Phase: High: 22.2 A, Low: 44.4 A Option -EHV Specifications Voltage/Frequency Ranges Voltage: Low: 0-200 Volt; High: 0-400 Volt / Frequency: With -HF option: 45 Hz - 5000 Hz Max RMS Current at Full Power 3 Phase: High: 5.0 A, Low 10.0 A; 1 Phase: High: 15.0 A, Low: 30.0 A; Note: Constant power modes on 3000Lx and 4500Lx. Current available at reduced voltage for 3000Lx, 4500Lx, and max voltage for 6000Lx Max RMS Current at FS Voltage 3000Lx: 3 Phase: High: 2.5 A, Low: 5.0 A; 1 Phase: High 7.5 A, Low: 15.0 A; 4500Lx: 3 Phase: High: 3.8, Low 7.5; 1 Phase: High: 11.3 A, Low: 22.5 A; 6000Lx: 3 Phase: High: 5.0 A, Low 10.0 A; 1 Phase: High: 15.0 A, Low: 30.0 A Option -HF Specifications Measurements: Parameter Frequency Phase Voltage (AC) Current Real Power Apparent Power (AC rms) Power Factor F < 2000 Hz: See standard Lx Range 45 - 5000 Hz < 2000 Hz 0-300 V 0-50 A 0-5 kW 0-5 kVA 0.00-1.00 > 2000 Hz < 1000 Hz / > 1000 Hz Specifications; Accuracy* (±) F > 2000 Hz: See table > 1 ø mode (-1) 0.1% + 1 digit 0.5° 0.05% + 250 mV 0.5% + 150 mA 0.5% + 9 W 0.5% + 9 VA 0.03 3 ø mode (-3) 5° 0.1% + 0.1%/kHz +300MV 0.5% + 50 mA 0.5% + 3 W 0.5% + 3 VA 0.01 Resolution* 0.01 Hz / 0.1 Hz / 1 Hz 0.1° / 1° 10 mV 1 mA 1 W 1 VA 0.01 * Accurac specifications are in % of reading and apply above 100 counts. For multi-chassis configurations, current, power range and accuracy specifications are times three. Power factor accuracy applies for PF > 0.5 and VA > 50% of max. Frequency measurement specification valid for output > 30 Vrms. 250 mVrms typical (20 kHz to 1 MHz) 3000Lx 34500Lx, 6000Lx: Standard: -HV 45 Hz- 5000 Hz; - EHV: 45 Hz - 5000 Hz Output Noise 250 mVrms typical (20 kHz to 1 MHz) © 2009 AMETEK Programmable Power All rights reserved. AMETEK Programmable Power is the trademark of AMETEK Inc., registered in the U.S. and other countries. Elgar, Sorensen, California Instruments, and Power Ten are trademarks of AMETEK Inc., registered in the U.S. sales@ProgrammablePower.com 195 858.458.0223 Lx Series Model¹ Output Power No of Output Phases Nom. Input Voltage² -1 -3 3000Lx 3 kVA 1 3 208-230 V 3000Lx-400 3 kVA 1 3 400 V 4500Lx 4.5 kVA 1 3 208-230 V 4500Lx-400 4.5 kVA 1 3 400 V 6000Lx 6 kVA 1 3 208-230 V 9000Lx/2 9 kVA 1 3 208-230 V 9000Lx/2-400 9 kVA 1 3 400 V 12000Lx/2 12 kVA 1 3 208-230 V 13500Lx/3 13.5 kVA 1 3 208-230 V 13500Lx/3-400 13.5 kVA 1 3 400 V 18000Lx/3 18 kVA 1 3 208-230 V Note 1: The /2 or /3 designation indicates number of chassis. Note 2: All input voltage specifications are for Line to Line three phase, delta or wye. Model 3000Ls (208 V input) can be operated on 230 V L-N single phase if needed. Ordering Information -ABD Airbus Directive 0100.1.8 tests. HF Table Model Max. Freq. [AC only]. Requires -ADV and use of Model Windows PC and included Refer to table shown for model numbers and 3000Lx 5000 Hz LxGui software. configurations. Specify number of output phases 4500Lx 5000 Hz (-1 or -3) as part of model number, eg 4500Lx-1 -AMD Airbus AMD24 Test 6000Lx 5000 Hz or 4500Lx-3. 9000Lx/2 2000 Hz -A350 Airbus Test Software Supplied with 12000Lx/2 2000 Hz -AIRB Airbus A380, A350 & AMD24 package User / Programming Manual on CD-ROM, 13500Lx/3 2000 Hz Software and RS232C serial cable. -ABL Emulates Elgar SL Series 18000Lx/3 2000 Hz Options -B787 Boeing 787 Test Software Input Options -ADV Advanced feature set. Adds arbitrary -400 400 ±10% Volt Line to Line AC input. waveform generation and harmonic [Not available on 6000Ls, 12000Ls and analysis of voltage and current. 18000Ls Models] -GPIB GPIB interface and APE programming -480 480 ±10% (3 phase output only) language. Output Options -LAN Ethernet Interface. -AX Auxiliary outputs, 26 VAC, 5 VAC. Limits upper frequency to 800 Hz. -MB Multi-box. Adds controller to auxiliary chassis of multi-chassis systems. -HV 156/312 V output range. -MODE Add phase mode selection for 3 models -EHV 200/400 V output range. -L22 Locking Knobs. -HF Extends upper frequency limit. See HF table. -LKM Clock and Lock Master -LF Limits output frequency to 500 Hz. -LKS Clock and Lock Auxiliary -LNS Line Sync. Keypad Options -RP LS style rotary knobs -EXS External Sync. Option Matrix Cabinet Options HF LF HV EHV LKM LKS EXS AX -RMS Rackmount Slides. Recommended for HF - X O O X X O X rack mount applications. LF X - O O O O O O C prefix Cabinet System. Installed and pre-wired HV O O - X O O O O in 19” cabinet. EHV O O X - O O O O Controller Options LKM X O O O - X O O -160 RTCA/DO-160, Change 2, EuroCAE-14D [Section 16, AC only] LKS X O O O X - X O EXS O O O O O X - O -704F Mil-Std 704 rev A - F AX X O O O O O O - -704 Mil-Std 704 rev D and E test firmware. [AC only] Note 1: See option matrix Note2 : -LKS, -LNS and -EXS are mutually exclusive and with Ext Trig function. 196 www.ProgrammablePower.com

Frequently asked questions

What makes Elite.Parts unique?

chervon down
At GID Industrial (Elite.Parts' parent company), we specialize in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

What kind of warranty will the 4500LX have?

chervon down
Warranties differ by part and by which suppliers we use to procure it for you. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carriers does Elite.Parts work with?

chervon down
Elite.Parts can ship via FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Will Elite.Parts sell to me even though I live outside the USA?

chervon down
Absolutely! We are happy to serve customers regardless of location. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

I have a preferred payment method. Will Elite.Parts accept it?

chervon down
All major credit cards are accepted: Visa, MasterCard, Discover, and American Express. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

Power Supply (AC), 270 VAC MAX, 47 Hz to 66 Hz, rack mount

4500 VA Single / 3-Phase AC Power Source

Power Supply (AC), 5000 W Max, 270 VAC Max, Single or Three Phase, 45 Hz to 2 kHz, Rackmount

product

California Instruments 4500Ls Power Source - Optional Ethernet LAN interface has been added. (Option...

product

California Instruments 4500LS-3 Power Source - Optional Ethernet LAN interface has been added. (Opti...

product

California Instruments 4500Ls-400 Power Source - Optional Ethernet LAN interface has been added. (Op...