CALIFORNIA INSTRUMENTS 12000Ls

Description
California Instruments 12000Ls Power Source - Optional Ethernet LAN interface has been added. (Option -LAN) The front panel graphic design has been enhanced for a more pleasing look.
Part Number
12000Ls
Price
Request Quote
Manufacturer
CALIFORNIA INSTRUMENTS
Lead Time
Request Quote
Category
PRODUCTS - 1
Specifications
Air Intake/Exhaust
Forced air cooling, side air intake, rear exhaust
Diagnostics
Built-in self test available over bus. (*TST).
Dimensions (per chassis)
Height:10.5" (267 mm), Width:19" (483 mm), Depth:23.7" (602 mm)
Efficiency
75 % typical
Ethernet Interface
Local Area Network 10BaseT, 100BaseT, RJ45 connector. (Option -LAN)
Frequency
± 0.025% 45 Hz - 819.1 Hz, ± 0.07% > 819.1 Hz
Frequency Range
With -HF option:3000Ls, 4500Ls, 6000Ls:45 Hz -5000 Hz, 9000Ls, 12500Ls, 13500Ls, 18000Ls:45 Hz -2000 Hz
Hold-up time
At least 10 ms
IEEE-488 Interface
IEEE-488 (GPIB) talker listener. Subset:AH1, DC1, DT1, L3, RL2, SH1, SR1, T6
Inrush Current (per phase)
@ 180-254 V 50 Apeak, @ 360-440 V 83 Apeak
Line Frequency
47 - 440 H
Line Regulation
Less than ± 0.02% for 10% line change
Load Regulation
Less than ± 0.1% FS
Maximum power per phase
Model:3000Ls Single Phase 3000 VA Three Phase 1000 VA, Model:4500Ls Single Phase 4500 VA Three Phase 1500 VA, Model:6000Ls Single Phase
Operating Temperature
0 to 35° C, full power.
Output noise
-100 mVrms typical (20 kHz to 1 MHz)
Phase
± 1° 45- 100 Hz, ±(1° + 1°/kHz) 100 Hz - 1 kHz
Power Factor
0.6 typical
Programming Accuracy (25°C±5°C)Voltage (rms)
±(0.05% + 0.25) V from 5.0 V to FS
Rear Panel Connectors
Three phase AC Input terminal block with safety cover, Three phase AC Output terminal block with safety cover, IEEE-488 (GPIB) connector (Option -GPIB), 9 pin D-Shell RS232C connector, Remote Inhibit (INH) and Discrete fault Indicator (DFI), Remote voltage sense terminal block, Trigger In1 and Trigger Out1, System Interface connectors, Aux. Output (Option -AX) (*RS232 DB9 to DB9 cable supplied)
Setup storage
16 complete instrument setups
Storage Temperature
-40 to 85° C.
Transient lists storage
100 transient steps per list (SCPI mode) or 16 transient
Trigger input
Triggers measurements or transient steps SMA connector: 10K pull-up
Trigger output
SMA connector: HC TTL output
Vibration and Shock
Designed to meet NSTA project 1A transportation levels
Voltage
Models 3000Ls, 4500Ls, 9000Ls, 13500Ls:Standard: 208-230 ±10% VAC, (L-L, 3 Phase) Option -400: 360-440 VAC, (L-L, 3 Phase) Models 6000Ls, 12000Ls, 18000Ls:Standard: 208-230 + 10% VAC,(L-L, 3 Phase)
Voltage Ranges
Low:0-135 Volt, High:0-270 Volt
Voltage Resolution
100 mV
Weight (per chassis)
193 lbs / 87.7 Kg net. 280 lbs / 127.3 Kg shipping
Datasheet
Extracted Text
Login | Modify User Info | Home Products | Literature | Software | Company | Contact Us | Sales / Service Contacts | Related Links Ls Series II Download PDF datasheet Changes from Series I The Series II versions of the Lx and Ls Series are backward compatible with the original Lx/Ls Series models. Series II models are different from the original Lx/Ls Series in the following areas: Standard USB interface has been added. Optional Ethernet LAN interface has been added. (Option -LAN). The front panel graphic design has been enhanced for a more pleasing look. The Output D and E terminal block is no longer installed on the standard Lx and Ls units unless the auxiliary output option -AX is installed. This makes the standard output terminal block more easily accessible. No other functional differences exist between the Series I and Series II AC power sources. The RS232C interface is still available in addition to the USB interface. The User Manual for Series I models is CI P/N 7004-960 and is available for download. For Series II models, refer to user manual CI P/N 7004-980 also available for download. General Description The Ls Series is an improved version of the classic California Instruments L Series AC power sources. It provides many basic AC source capabilities at an economical cost. Additional capabilities such as arbitrary waveform generation and harmonic measurements can be added as options. The Ls Series can be ordered in either single phase (-1) or three phase (-3) configurations. Power levels range from 3 kVA to 6 kVA in a single chassis. Multiple chassis can be combined for power levels up to 18 kVA. The Ls Series is completely microprocessor controlled and can be operated from a simple front panel keypad. A pair of analog controls located next to the backlit alphanumeric LCD display allows output voltage and frequency to be slewed up or down dynamically. For more advanced operations, a series of menus is provided using a dual line high contrast LCD display. L Series Backward Compatibility The Ls Series offers functional and bus compatibility with the CI L Series AC power sources. Using the APE (Abbreviated Plain English) command syntax, the Ls Series can be used in existing test systems without the need to modify program code. The APE language is part of the -GPIB option, which also adds the GPIB/ IEEE-488 interface. Applications With precise output regulation and accuracy, high load drive current, multi or single phase mode and built-in measurement capabilities, Ls Series AC sources address many application areas for AC power testing. Additional features, like available DO 160 or MIL 704 test standards, make the Ls Series a good choice for avionics or defense applications. All Ls Series AC sources are standard equipped with RS232C remote control interfaces. An optional GPIB interface is available as well. Transient Programming To simulate common line disturbance occurrences, the Ls Series offers a list of transient steps. These steps can be programmed from the front panel or downloaded over the interface using the GUI program supplied. The GUI allows libraries of commonly used line disturbances to be created on disk for quick recall. Once downloaded, the transient program can be executed from the PC or from the front panel. AC transient generation allows the effect of rapid changes in voltage, frequency, phase angle and waveform shape on the unit under test to be analyzed. Measurements The following standard measurements are available from the front panel or via the bus: Frequency Phase Voltage (rms) Current(rms) Peak Current Crest Factor Real Power Apparent Power Power Factor Diagnostics Capability The AC Source can perform a self test and report any errors. The self test will run until the first error is encountered and terminate. The response to the self test query command will either be the first error encountered or 0 if no error was found. (Self test passed). Configuration Options The Ls Series is available in either three or one phase output configurations and offers voltage ranges of 135 Vrms and 270 Vrms. A wide range of options can be added to customize the Ls Series to meet your specific application requirements. Voltage Range Options (-HV and -EHV) Output voltage range options are available to provide higher voltage outputs. In addition to the standard 135/270 V range pair, 156/312 Vrms (-HV option) and 200/400 Vrms (-EHV option) can be specified at the time of order. All voltage ranges are Line to Neutral. On three phase Ls Series models, maximum Line to Line voltages are 467 V (standard), 540 V (-HV option) and 692 V (-EHV option). Phase Mode (-MODE) The -MODE option provides automatic switching between three phase and single phase output modes. In single phase mode, all output current is routed to the Phase A output terminal. The -MODE option is available for 3 phase Ls models (e.g. 4500Ls-3). Waveform Generation (-ADV option) The standard Ls Series provides sine wave output capability. For more demanding test applications, the advanced option package adds the following waveform capabilities: Squarewave. Clipped Sinewave - Simulates THD levels to test for harmonic distortion susceptibility. Harmonic and Arbitrary (User defined) waveforms. Using the provided Windows Graphical User Interface (GUI) program, defining harmonic waveforms is as easy as specifying the relative amplitude and phase angle for each of up to 50 harmonics. The waveform data points are generated and downloaded by the GUI to the AC source through the standard RS232C or optional GPIB bus and are retained in non-volatile memory. Up to 50 waveforms can be stored and given a user defined name for easy recall. Advanced Measurement Functions (-ADV option) Power analysis of EUT load characteristics is available by adding the -ADV option. Harmonics up to the 50th harmonic (for fundamental frequencies up to 250 Hz) and total harmonic distortion of both voltage and current is provided as well. Harmonic analysis data can be displayed on the front panel display or on the PC using the GUI program. The GUI can also be used to save and print harmonics data in tabular, bar graph or time domain formats. The acquired voltage and current time-domain waveforms for each output phase can be displayed using the GUI program. Waveform displays on the PC. Available display modes include voltage and current combined, three phase voltage, three phase current and true power. The time-domain data is also available for transfer to a PC through the bus when using custom software. Windows Graphical User Interface A Windows compatible Graphical User Interface (GUI) offers a soft front panel interface for operation from a PC. The following functions are available through this GUI program: Steady state output control (all parameters). Create, run, save and print transient programs. Measure and log standard measurements. With -ADV option: Generate and save harmonic waveforms. Generate and save arbitrary waveforms. Capture and display Voltage and Current waveforms. Measure, display, print and log harmonic voltage and current measurements. Specifications Output Input Power Voltage Models 3000Ls, 4500Ls, 9000Ls, 13500Ls: Maximum power per phase: Standard: 208-230 ±10% VAC, (L-L, 3 Phase) Model: Single Three Option -400: 360-440 VAC, (L-L, 3 Phase) Phase Phase Models 6000Ls, 12000Ls, 18000Ls: 3000Ls 3000 VA 1000 VA Standard: 208-230 + 10% VAC,(L-L, 3 Phase) 4500Ls 4500 VA 1500 VA Notes: 6000Ls 5770 VA 1923 VA 1. Input range must be specified when ordering. Power Factor 2 400 option not available on 6000Ls, 12000Ls or 0 to unity at full output VA 18000Ls. Voltage Ranges Line Current (rms per phase) Low : 0-135 Volt Model: 187 VLL 360 VLL High : 0-270 Volt 3000Ls; 19 A 10 A Contact factory for optional alternate voltage range pairs. 3000Ls (1ø); 32 A n/a Voltage Resolution 100 mV 4500Ls; 31 A 16 A Load Regulation 6000Ls (@208V); 38 A n/a Less than ± 0.1% FS Inrush Current (per phase) Line Regulation @ 180-254 V 50 A peak Less than ± 0.02% for 10% line change @ 360-440 V 83 A peak Programming Accuracy (25°C±5°C) Line Frequency Voltage (rms): 47 - 440 H ±(0.05% + 0.25) V from 5.0 V to FS Efficiency Frequency: 75 % typical ± 0.025% 45 Hz - 819.1 Hz Power Factor ± 0.07% > 819.1 Hz 0.6 typical Hold-up Time Phase: At least 10 ms ± 1° 45- 100 Hz ±(1° + 1°/kHz) 100 Hz - 1 kHz Frequency Range 45 Hz - 1000 Hz Max RMS Current @ full power V Range V high V low -3 3 Phs 7.4 A 14.8 A -1 1 Phs 22.2 A 44.4 A Note: Constant power modes on 3000Ls and 4500Ls. Current available at reduced voltage for 3000Ls, 4500Ls and max voltage for 6000Ls.. Max RMS Current @ FS Voltage V Range V high V low 3000Ls 3 Phs 3.7 A 7.4 A 1 Phs 11.1 A 22.2 A 4500Ls 3 Phs 5.5 A 11.1 A 1 Phs 16.7 A 33.3 A 6000Ls 3 Phs 7.4 A 14.8 A 1 Phs 22.2 A 44.4 A Current Limit Programmable from 0 A to max. current for selected range. Peak Current 3000Ls: 6 x Irms at FS voltage. 4500Ls: 4 x Irms at FS voltage. 6000Ls: 3 x Irms at FS voltage. Output Noise -100 mVrms typical (20 kHz to 1 MHz) Harmonic Distortion < 1% (At full scale voltage, full resistive load.) Isolation Voltage 300 V rms output to chassis Output Relay Push button controlled and bus controlled output relay Measurements Parameter Range Accuracy* (±) Resolution 1 ø mode 3 ø mode Frequency 45.00 - 81.91 Hz 0.1% + 1 digit 0.01 Hz 82.0 - 819.1 Hz 0.1 Hz > 819 Hz 1 Hz Phase 45 - 100 Hz 0.5° 00.1° 100 - 1000 Hz 2° 1° Voltage (AC) 0 -300 V 0.05% + 250mV 10 mV Current (AC rms) 0 - 50 A 0.1% + 150 mA 0.1% + 50 mA 1 mA Real Power 0 - 5 kW 0.15% + 9 W 0.15% + 3 W 1 W Apparent Power 0 - 5 kVA 0.15% + 9 VA 0.15% + 3 VA 1 VA Power Factor 0.00 - 1.00 0.03 0.01 0.01 * Accuracy specifications are in % of reading. Frequency measurement accuracy applies for output voltages of 20Vrms and higher. System Physical Setup storage Dimensions (per chassis) 16 complete instrument setups Height: 10.5" (267 mm) Width: 19" (483 mm) Transient lists storage 100 transient steps per list (SCPI mode) or 16 transient Depth: 23.7" (602 mm) registers (APE mode). Depth includes rear panel connectors and safety covers. All weights and dimension are per chassis. Trigger input Weight (per chassis) Triggers measurements or transient steps 193 lbs / 87.7 Kg net. SMA connector: 10K pull-up 280 lbs / 127.3 Kg shipping Vibration and Shock Trigger output Designed to meet NSTA project 1A transportation levels SMA connector: HC TTL output. Air Intake/Exhaust Forced air cooling, side air intake, rear exhaust Operating Temperature Remote Control 0 to 35° C, full power. Ethernet Interface Storage Temperature Local Area Network 10BaseT, 100BaseT, RJ45 -40 to 85° C. connector. (Option -LAN) Diagnostics IEEE-488 Interface Built-in self test available over bus. (*TST). IEEE-488 (GPIB) talker listener. Rear Panel Connectors Subset: Three phase AC Input terminal block with safety cover AH1, DC1, DT1, L3, RL2, SH1, SR1, T6 Three phase AC Output terminal block with safety cover RS232C Interface IEEE-488 (GPIB) connector (Option -GPIB) Bi-directional serial interface. 9 pin D-Shell RS232C connector 9 pin D-shell connector Remote Inhibit (INH) and Discrete fault Indicator (DFI) Handshake: CTS, RTS Remote voltage sense terminal block Data bits: 7 with parity, Trigger In1 and Trigger Out1 System Interface connectors 8 without parity Aux. Output (Option -AX) Stop bits: 2 (*RS232 DB9 to DB9 cable supplied) Baud rate: 9600 to 115200 Supplied with RS232C cable Code and Format SCPI APE (option -GPIB) Option Specifications All specifications same as standard Ls models except where noted. -ADV Option Waveforms Pre defined: Sine, Square, Clipped User defined, 1024 addressable data points. Storage: 50 user waveforms, non-volatile memory. Data Acquisition Parameters: Voltage, Current time domain, per phase. Resolution: 4096 data points, 10.4 usec (1 phase) or 31.25 usec (3 phase) sampling interval. Measurements - Harmonics Parameter Range Accuracy* (±) Resolution Frequency 45 - 250 Hz 0.1% + 1 digit 0.01 Hz Fundamental 0.09-12.5 kHz 0.5% + 1 digit 0.1 Hz Voltage Fundamental 0.05% + 250mV 10 mV Harmonics 2 - 50 0.1%+0.1%/KHz+250mV 10 mV Current Fundamental 50 mA 10 mA Harmonics 2 - 50 0.1% + 50 mA +0.1% /1 kHz 10 mA * Accuracy specifications are in % of reading for single unit in 3 phase mode. -HV Option Voltage Ranges Low : 0-156 Volt High : 0-312 Volt Max RMS Current @ full power V high V low V Range Mode: 3 Phs 6.4 A 12.8 A Mode: 1 Phs 19.2 A 38.4 A Note: Constant power modes on 3000Ls and 4500Ls. Current available at reduced voltage for 3000Ls, 4500Ls and max voltage for 6000Ls. Max RMS Current @ FS Voltage V Range V high V low 3000Ls 3 Phs 3.2 A 6.4 A 1 Phs 9.6 A 19.2 A 4500Ls 3 Phs 4.8 A 9.6 A 1 Phs 14.4 A 28.8 A 6000Ls 3 Phs 6.4 A 12.8 A 1 Phs 19.2 A 38.4 A Frequency Range: With -HF option: 3000Ls, 4500Ls, 6000Ls: 45 Hz - 5000 Hz 9000Ls, 12500Ls, 13500Ls, 18000Ls: 45 Hz - 2000 Hz -EHV Option All specifications same as standard Ls models except where noted. Voltage Ranges Low : 0-200 Volt High : 0-400 Volt Max RMS Current @ full power V high V low V Range Mode: 3 Phs 5.0 A 10.0 A Mode: 1 Phs 15.0 A 30.0 A Note: Constant power modes on 3000Ls and 4500Ls. Current available at reduced voltage for 3000Ls, 4500Ls and max voltage for 6000Ls. Max RMS Current @ FS Voltage V Range V high V low 3000Ls 3 Phs 2.5 A 5.0 A 1 Phs 7.5 A 15.0 A 4500Ls 3 Phs 3.8 A 7.5 A 1 Phs 11.3 A 22.5 A 6000Ls 3 Phs 5.0 A 10.0 A 1 Phs 15.0 A 30.0 A Frequency Range: With -HF option: 45 Hz - 2000 Hz -HF Option Frequency Range: 3000Ls, 4500Ls, 6000Ls Standard, -HV: 45 Hz - 5000 Hz -EHV: 45 Hz - 2000 Hz All other models: 45 Hz - 2000 Hz Output Noise 250 mVrms typical (20 kHz to 1 MHz) Measurements F < 2000 Hz: See standard Ls specifications. F > 2000 Hz: See table. Parameter Range Accuracy* (±) Resolution 1 ø mode 3 ø mode Frequency See standard Ls 1 Hz Phase < 2000 Hz See standard Ls > 2000 Hz 5° 1° Voltage (AC) 0 -300 V < 1000 Hz 0.05% + 250mV 10 mV > 1000 Hz 0.1% + 0.1%/KHz + 300 mV 10 mV Current (AC rms) 0 - 50 A 0.5% + 150 mA 0.5% + 50 mA 1 mA Real Power 0 - 5 kW 0.5% + 9 W 0.5% + 3 W 1 W Apparent Power 0 - 5 kVA 0.5% + 9 VA 0.5% + 3 VA 1 VA Power Factor 0.00 - 1.00 0.03 0.01 0.01 * See standard measurement specifications for notes. Ordering Information Model Output Phase Input 1 Power Output Voltage 3000Ls 3 kVA 1/3 208-230V ±10 % 4500Ls 4.5 kVA 1/3 208-230V ±10 % 4500Ls-400 4.5 kVA 1/3 400V ±10% 6000Ls 6 kVA 1/3 208-230V ±10 % 9000Ls 9 kVA 1/3 208-230V ±10 % 9000Ls-400 9 kVA 1/3 400V ±10% 12000Ls 12 kVA 1/3 208-230V ±10 % 13500Ls 13.5 kVA 1/3 208-230V ±10 % 13500Ls-400 13.5 kVA 1/3 400V ±10% 18000Ls 18 kVA 1/3 208-230V ±10 % Note (1): All input voltage specifications are for Line-to-Line three phase, delta or wye. Model 3000Ls (208 V input) can be operated on 230 V L-N single-phase if needed. Options C prefix Cabinet System. Installed and pre-wired in 19 cabinet. Input Options -400 400 Volt Line-to-Line AC input. [Not available on 6000Ls model or 12000Ls and 18000Ls Systems] Output Options -AX1 Auxiliary outputs, 26 VAC, 5 VAC. Limits upper frequency to 800 Hz. -HV1 135/270 V output range. -EHV1 200/400 V output range. -HF1 Extends upper frequency limit. See HF table. HF Table Models Max. Freq. 3000Ls, 4500Ls, 6000Ls 5000 Hz 9000Ls/2, 12000Ls/2, 13500Ls/2, 18000Ls/2 2000 Hz -LF1 Limits output frequency to 500 Hz. Note 1: See option matrix Keypad Options -KPD Upgraded keypad control panel. Controller Options -160 RTCA/DO-160D, Change 2, EuroCAE-14D and Airbus test firmware [Section 16, AC only] -704 Mil-Std 704 Rev D and E test firmware. [AC only] -ABD Airbus Directive 0100.1.8 tests. [AC only]. Requires -ADV and use of Windows PC and included LxGui software. -ADV Advanced feature set. Adds arbitrary waveform generation and harmonic analysis of voltage and current. -GPIB GPIB interface and APE programming language -LAN Ethernet Interface -MB Multi-box. Adds controller to auxiliary chassis of multi-chassis systems. -MODE Adds phase mode selections for -3 models. -L22 Locking Knobs -LKM1 Clock and Lock Master -LKS1,2 Clock and Lock Auxiliary -LNS2 Line Sync. -EXS2 External Sync. Note 1: See option matrix Note2 : -LKS, -LNS and -EXS are mutually exclusive and with Ext Trig function. Cabinet Options -RMS Rack-mount slides. Recommended for rack-mount applications. C prefix Cabinet System. Installed and pre-wired in 19 cabinet. Option Matrix: Note that some options are mutually exclusive as indicated in the table below. An o means the options can be combined. An x means they cannot. HF LF HV EHV LKM LKS EXS AX - x o o x x x x HF x - o o o o o o LF HV o o - o o o o o EHV x o x - o o o o LKM x o o o - x o o LKS x o o o x - x o o o o o o x - o EXS AX x o o o o o o - © 2002 California Instruments Home | Top | Back Terms of use and legal restrictions Privacy Policy
Frequently asked questions
What makes Elite.Parts unique?

What kind of warranty will the 12000Ls have?

Which carriers does Elite.Parts work with?

Will Elite.Parts sell to me even though I live outside the USA?

I have a preferred payment method. Will Elite.Parts accept it?

Why buy from GID?

Quality
We are industry veterans who take pride in our work

Protection
Avoid the dangers of risky trading in the gray market

Access
Our network of suppliers is ready and at your disposal

Savings
Maintain legacy systems to prevent costly downtime

Speed
Time is of the essence, and we are respectful of yours
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods