AULT / SL POWER HD3-30-2A

Description
30W DC/DC Converter
Part Number
HD3-30-2A
Price
Request Quote
Manufacturer
AULT / SL POWER
Lead Time
Request Quote
Category
PRODUCTS - H
Datasheet
Extracted Text
30W-40W DC-DC CONVERTERS ✔ Single and Triple Output Models ✔ Wide Input Ranges ✔ 5V, 12V, 15V Outputs ✔ Pi Input Filters—Built-in EMI Suppression ✔ UL/CSA/VDE/EN Safety Standards ✔ 850-1500V Input/Output Isolation ✔ Short-Circuit/Over-Voltage Protection ✔ Remote Load Sensing ✔ Remote Shutdown/Output Adjustment ✔ 3” ✕ 3” Six-Sided Metal Case ✔ 2-Year Warranty ✔ 700,000-Hour Minimum MTBF Nominal Max. CHARACTERISTICS Input Voltage Input DC Output Output Line/ Min.Nom.Max. Current Output Current Voltage Load Effi- EMI Suppression..........................Pi input filter, standard. Model (V) (V) (V) (A) Output(V) (A) Tolerance Reg. ciency Base-Plate Temperature...............Operating temperature of +100°C, max.with built-in thermal shutdown. DC-DC 30W Singles Isolation Voltage...........................D-input models: 1500V, input to output, HD1-30-5A 9.0 12 25 3.16 V1 5.0 6.00 1.0% 0.3% 79% for one minute. A- and B-input models: HD1-30-5B 18 24 36 1.52 V1 5.0 6.00 1.0% 0.3% 82% 850V, input to output, for one minute. HD1-30-5D 36 48 75 0.75 V1 5.0 6.00 1.0% 0.3% 83% Output Adjustment........................Primary output adjustable ±10%. Continuous Output Power ............HD1-30 and HD3-30 total output HD1-30-12A 9.0 12 25 3.09 V1 12 2.50 1.0% 0.3% 81% power should not exceed 30W. HD1- HD1-30-12B 18 24 36 1.51 V1 12 2.50 1.0% 0.3% 83% 40 and HD3-40 total output power HD1-30-12D 36 48 75 0.75 V1 12 2.50 1.0% 0.3% 83% should not exceed 40W. Maximum output current for individual outputs of HD1-30-15A 9.0 12 25 3.01 V1 15 2.00 1.0% 0.3% 83% triple output models appear in the rat- HD1-30-15B 18 24 36 1.51 V1 15 2.00 1.0% 0.3% 83% ings table. HD1-30-15D 36 48 75 0.73 V1 15 2.00 1.0% 0.3% 86% Minimum Load Requirement ........Single output models, no minimum. Triple output models, 150 mA, mini- † DC-DC 30W Triples mum on 5V output, 50 mA, minimum, V1 5.0 6.00 1.0% 0.3% on auxiliary outputs. HD3-30-1A 9.0 12 25 3.21 V2 +12 0.50 2.5% 5.0% 78% Output Noise and Ripple..............5V output, 50 mVpp, maximum. 12V V3 - 12 0.50 2.5% 6.0% and 15V outputs, 75 mVpp, maxi- mum. (See Note 2.) V1 5.0 6.00 1.0% 0.3% Short-Circuit Protection ................Cycle-by-cycle current limiting. HD3-30-1B 18 24 36 1.54 V2 +12 0.50 2.5% 5.0% 81% Over-Voltage Protection ...............V1 output only: 125% of rated output, V3 - 12 0.50 2.5% 6.0% typical. Single output models with 5V V1 5.0 6.00 1.0% 0.3% outputs and all triple output models HD3-30-1D 36 48 75 0.76 V2 +12 0.50 2.5% 5.0% 82% have latching OVP; RESET = 0V. All V3 - 12 0.50 2.5% 6.0% other models are diode protected. Under-Voltage Lockout.................Nom. Input Off (Typ.) On (Typ.) V1 5.0 6.00 1.0% 0.3% 12V 7.5V 8.5V HD3-30-2A 9.0 12 25 3.21 V2 +15 0.40 2.5% 5.0% 78% 24V 16.5V 17.5V V3 - 15 0.40 2.5% 7.0% 48V 34.0V 35.5V V1 5.0 6.00 1.0% 0.3% Transient Response .....................200 µs recovery after half-load to full load HD3-30-2B 18 24 36 1.54 V2 +15 0.40 2.5% 5.0% 81% step change to within 1% of the regulation V3 - 15 0.40 2.5% 7.0% band with no more than 5% deviation. V1 5.0 6.00 1.0% 0.3% Frequency of Operation ...............300 kHz. HD3-30-2D 36 48 75 0.76 V2 +15 0.40 2.5% 5.0% 82% Remote Shutdown........................CMOS and open-collector TTL com- V3 - 15 0.40 2.5% 7.0% patible: ON = 2.4V to VIN(MAX); OFF = 0.8V or less. Logic reference is -VIN. DC-DC 40W Singles Temperature Range......................-40°C to +85°C (ambient). See HD1-40-5A 9.0 12 25 4.20 V1 5.0 8.00 1.0% 0.3% 79% Package Power De-Rating graph. HD1-40-5B 18 24 36 2.03 V1 5.0 8.00 1.0% 0.3% 82% Temperature Coefficient ...............±0.02%/°C over the entire operating HD1-40-5D 36 48 75 1.00 V1 5.0 8.00 1.0% 0.3% 83% temperature range. Relative Humidity .........................0 to 95%, non-condensing. HD1-40-12A 9.0 12 25 4.12 V1 12 3.33 1.0% 0.3% 81% Altitude .........................................0 to 10,000 feet. HD1-40-12B 18 24 36 2.01 V1 12 3.33 1.0% 0.3% 83% Cooling .........................................Convection cooling is adequate. HD1-40-12D 36 48 75 1.00 V1 12 3.33 1.0% 0.3% 83% Moving air is recommended for opera- HD1-40-15A 9.0 12 25 4.02 V1 15 2.67 1.0% 0.3% 83% tion in a confined area. See Package Power De-Rating graph. HD1-40-15B 18 24 36 2.01 V1 15 2.67 1.0% 0.3% 83% Storage Temperature....................-40°C to +100°C. HD1-40-15D 36 48 75 0.97 V1 15 2.67 1.0% 0.3% 86% † Storage Humidity..........................0 to 95%, non-condensing. HD3-30 models with tightly regulated auxiliary outputs are available. For more Mean Time Between Failures.......>700,000 hours. (See Note 4.) information, contact Power General applications engineering. POWER 152 Will Drive · Canton, MA 02021 USA · Phone 781-828-6216 · Fax 781-830-1155 · Email power@nidecpg.com · http://www.nidec.com GENERAL 47 30W-40W DC-DC CONVERTERS PACKAGE POWER DE-RATING Nominal Max. — Flat Base Plate — Input Voltage Input DC Output Output Line/ Min.Nom.Max. Current Output Current Voltage Load Effi- Model (V) (V) (V) (A) Output(V) (A) Tolerance Reg. ciency † DC-DC 40W Triples V1 5.0 8.00 1.0% 0.3% HD3-40-1A 9.0 12 25 4.27 V2 +12 0.50 2.5% 5.0% 78% V3 - 12 0.50 2.5% 6.0% V1 5.0 8.00 1.0% 0.3% HD3-40-1B 18 24 36 2.06 V2 +12 0.50 2.5% 5.0% 81% V3 - 12 0.50 2.5% 6.0% V1 5.0 8.00 1.0% 0.3% HD3-40-1D 36 48 75 1.02 V2 +12 0.50 2.5% 5.0% 82% V3 - 12 0.50 2.5% 6.0% V1 5.0 8.00 1.0% 0.3% HD3-40-2A 9.0 12 25 4.27 V2 +15 0.40 2.5% 5.0% 78% V3 - 15 0.40 2.5% 7.0% PACKAGE POWER DE-RATING V1 5.0 8.00 1.0% 0.3% — Cross-Cut Heat Sink — HD3-40-2B 18 24 36 2.06 V2 +15 0.40 2.5% 5.0% 81% V3 - 15 0.40 2.5% 7.0% V1 5.0 8.00 1.0% 0.3% HD3-40-2D 36 48 75 1.02 V2 +15 0.40 2.5% 5.0% 82% V3 - 15 0.40 2.5% 7.0% † HD3-40 models with tightly regulated auxiliary outputs are available. For more information, contact Power General applications engineering. 30W AND 40W HD SERIES A. Dimensions shown are in inches. B. Tolerances = 0.00 ±0.01 inch. 0.000 ±0.005 inch. C. HD1-40 and HD3-40 models are normally supplied with a flat base plate. To specify an HD1-40 or HD3-40 model with the optional cross-cut heat sink, add the letter “H” to the end of the part number (e.g., HD1-40-5AH). D. Module weight: HD1-30, HD3-30, HD1-40 and HD3-40, no heat sink = 4 oz. (113g). HD1-40 and HD3-40 with cross-cut heat sink = 5 oz. (142g). Pin-Out Pin HD1-30/HD1-40 HD3-40/HD3-40 1- VIN - VIN 2+VIN +VIN 3 Case Case 4 Remote On/Off Remote On/Off 5 Output Adjust Output Adjust 6 +V1OUT V1OUT 7- V1OUT Return 8 +Sense V2OUT 9 - Sense V3OUT Notes 1. Use of an external input line fuse is recommended: 2. Peak-to-peak and RMS metering equipment must have a For HD1-30 and HD3-30 models with 12V input, use an 20 MHz frequency response with probes and cables that Output Adjustment 6.0A/125V slow-blow fuse. maintain a frequency response of 20 Hz to 20 MHz. For HD1-30 and HD3-30 models with 24V input, use a Output ripple and spikes are measured directly at the out- 3.0A/125V slow-blow fuse. put terminals of the dc-to-dc converter with a 0.1 µF For HD1-30 and HD3-30 models with 48V input, use a ceramic capacitor. The instruments’ probe ground bands 2.0A/125V slow-blow fuse. must make direct contact with the output return pin or the For HD1-40 and HD3-40 models with 12V input, use an common terminal of the converter in order to prevent erro- 8.0A/125V slow-blow fuse. neous noise measurements. For HD1-40 and HD3-40 models with 24V input, use a 3. All measurements are at nominal input, full load, and 4.0A/125V slow-blow fuse. +25°C unless otherwise specified. For HD1-40 and HD3-40 models with 48V input, use a 4. MTBF is calculated using the parts stress method in MIL- 2.0A/125V slow-blow fuse. HDBK 217F (ground benign, T = +25°C). A POWER 152 Will Drive · Canton, MA 02021 USA · Phone 781-828-6216 · Fax 781-830-1155 · Email power@nidecpg.com · http://www.nidec.com GENERAL 48
Frequently asked questions
What makes Elite.Parts unique?

What kind of warranty will the HD3-30-2A have?

Which carriers does Elite.Parts work with?

Will Elite.Parts sell to me even though I live outside the USA?

I have a preferred payment method. Will Elite.Parts accept it?

What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods