Description
225W AC/DC Switch-Mode Power Supply
Part Number
FLU4-225-1CDP
Price
Request Quote
Manufacturer
AULT / SL POWER
Lead Time
Request Quote
Category
PRODUCTS - F
Datasheet
Extracted Text
225W ENCLOSED QUAD OUTPUT SWITCHING POWER SUPPLIES ✔ 225W Continuous Output Power ✔ Auto-Ranging AC Input and DC-Input Models ✔ Power-Fail Warning Signal ✔ ±3% Margining ✔ Remote Sense and Remote ON/OFF ✔ Over-Current and Short-Circuit Protection ✔ Thermal Shutdown Protection ✔ CE Mark: UL/CSA/EN60950 Approvals ✔ EN55022/FCC Class B Input Line Filter ✔ 2-Year Warranty ✔ Minimum 200,000-Hour MTBF CHARACTERISTICS Input Voltage.............................FLU models, auto-ranging input volt- age range, 90-265 VAC, single phase. DC-input models, 38-72 VDC (48V, nominal). Output Current Output Input Line Frequency ................FLU models, 47-440 Hz (50/60 Hz, Output Voltage Min. Nom. Max. Voltage Line Load Cross- nominal). Model Output (V) (A) (A) (A) Tol. Reg. Reg. Reg. Input Line Protection.................MOV transient-protected (FLU mod- els). Input line fuse on-board (Note 1). AC-DC Quad Output 90-265 VAC Input EMI Filter...................................Standard. Performance surpasses FLU4-225-1CDP V1 5.0 3.0 30.0 30.0 1.0% 0.2% 0.5% — conducted EMI requirements of V2 +12 0.0 4.00 4.00 1.0% 0.2% 0.5% 1.0% EN55022/FCC Class B by 10 dB, typ. V3 - 12 0.0 2.00 3.00 1.0% 0.2% 0.5% 1.0% Continuous Output Power.........225W, maximum. V4 5.0(ISO) 0.0 1.50 1.50 3.0% 0.2% 1.0% 1.0% Output Voltage Adjust ...............V1 adjustable ±5%. V2 adjustable ±5% (models 1,3); V2 adjustable DC-DC Quad Output 38-72 VDC Input ±2% (model 2). V4 fixed. DC4-225-1CCP V1 5.0 3.0 30.0 30.0 1.0% 0.2% 0.5% — Efficiency...................................65%, minimum (FLU models, 115 or V2 +12 0.0 4.00 4.00 1.0% 0.2% 0.5% 1.0% 230 VAC input, DC models, 48V V3 - 12 0.0 2.00 3.00 1.0% 0.2% 0.5% 1.0% input, full load conditions). V4 5.0(ISO) 0.0 1.50 1.50 3.0% 0.2% 1.0% 1.0% Hold-Up Time............................16 ms at 115 VAC input, 32 ms at 230 VAC input, minimum, full load conditions (FLU models). Overload Protection ..................Independent current limiting, each output. Short-Circuit Protection.............Continuous. Over-Voltage Protection............V1, V2, V3, standard on all models. Soft Start...................................Standard on all models. Design Topology .......................Forward converter, current-mode control. Frequency of Operation ............125 kHz (fixed). Electrical Strength/Isolation......5300 VDC, input-to-output for one minute. (Note 2.) Noise, Ripple and Spike ...........1% peak-to-peak, max. (See Note 4.) Transient Response..................4 ms recovery to within 1% of the regulation band with no more than 5% deviation. Margining ..................................V1, ±3%, nominal. Remote On/Off..........................TTL compatible (logic 1 or OPEN = ON, logic 0 = OFF). Power-Fail Warning...................TTL compatible (logic 1, 5 ms, mini- mum, before loss of output). Temperature Range ..................-20°C to +70°C. Output Power De-Rating...........De-rate output power and current linearly 2%/°C from +50°C to +70°C. Temperature Coefficient............±0.05%/°C over the entire operating temperature range. Relative Humidity......................0 to 95%, non-condensing. Altitude ......................................0 to 10,000 feet. Cooling......................................Cooling fan built-in. Storage Temperature ................-40°C to +85°C. Storage Humidity ......................0 to 95%, non-condensing. Mean Time Between Failures ...>200,000 hours (Note 5). POWER 152 Will Drive · Canton, MA 02021 USA · Phone 781-828-6216 · Fax 781-830-1155 · Email power@nidecpg.com · http://www.nidec.com GENERAL 38 225W ENCLOSED QUAD OUTPUT SWITCHING POWER SUPPLIES FLU4-225/DC4-225 A. Dimensions shown are in inches. B. Tolerances = 0.00 ±0.01 inch. 0.000 ±0.005 inch. C. The TB1 input connector is a three-position screw terminal. D. The TB2 output connector is a seven-posi- tion screw terminal E. The P1 output connector is Molex 22-05- 3051. The mating connector combines Molex housing 22-01-3057 and Molex crimp terminal 08-50-0114. Pin-Out FLU4-225 DC4-225 FLU4-225 DC4-225 Pin TB2 TB2 P1 P1 1 V4 Return V4 Return Low Margin Low Margin 2 V4 V4 Common Margin Common Margin 3 V3 V3 High Margin High Margin 4 V2/V3 Common V2/V3 Common Power Fail Power Fail 5 V2 V2 Remote ON/OFF Remote ON/OFF § § 6 +Sense +Sense N/A N/A § § 7 -Sense -Sense N/A N/A § If REMOTE SENSE terminals are not used, tie Pin 6 of TB2 to V1 and and tie Pin 7 of TB2 to the V1 Return stud. Notes 6. Output voltage tolerance is measured under nominal load current condi- 1. Replace the input line fuse with the same type and rating. tions specified for the power supply. Recommended: 5.0A/250V slow-blow fuse (ac-dc models); 10A/125V 7. Line regulation is measured under nominal load conditions as the input slow-blow fuse (dc-dc models). voltage is varied from 90 to 132 VAC and 180 to 265 VAC (ac-input mod- 2. Electrical strength/isolation is 2200 VDC from the input of the supply to els) or from 38 to 72 VDC (dc-input models). ground for 60 seconds. 8. Load regulation is measured at 115 VAC or 230 VAC input (ac-input mod- 3. All measurements are made directly at the terminals of the supply. els) or at 48 VDC (dc-input models). The output under test is brought to 4. Peak-to-peak and RMS metering equipment must have a 20 MHz fre- 60% of nominal load; load current and is then varied ±40% of nominal quency response with probes and cables that maintain a frequency while other outputs are held at nominal load current conditions. response of 20 Hz to 20 MHz. Output ripple and spikes are measured 9. Cross-regulation is tested by changing the load on the primary output directly at the output terminals of the power supply with a 0.1 µF ceramic from 15A to 30A while measuring the voltage change on the auxiliary out- capacitor. The probe ground band must make direct contact with the out- put under test. put return or the common terminal of the power supply to prevent erro- 10. The FLU4-225-1 is approved to UL1950 (File E140439), CAN/CSA22.2 neous noise measurements. No. 234 (File LR52335), and EN60950/IEC950/DIN VDE 0805 (TÜV 5. MTBF is calculated using the parts stress method in MIL-HDBK 217F License B 94 07 18771 007). Power General model DC4-225-1 is approved to (ground benign, T = +25°C). UL1950 (File E140439). A POWER 152 Will Drive · Canton, MA 02021 USA · Phone 781-828-6216 · Fax 781-830-1155 · Email power@nidecpg.com · http://www.nidec.com GENERAL 39
Frequently asked questions
What makes Elite.Parts unique?

What kind of warranty will the FLU4-225-1CDP have?

Which carriers does Elite.Parts work with?

Will Elite.Parts sell to me even though I live outside the USA?

I have a preferred payment method. Will Elite.Parts accept it?

What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods