Specifications
Altitude
0 to 10,000 feet
Continuous Output Power
65W, maximum
Cooling
Convection cooling is adequate; Moving air is recommended for operation in a confined area
Design Topology
Flyback converter with current-mode control
Efficiency
65%, minimum, 115 or 230 VAC input, full load conditions
Electrical Strength/Isolation
5300 VDC, input-to-output for one minute
EMI Filter
Standard. Performance surpasses conducted EMI requirements of EN55022/FCC Class B by 10 dB, typ
Frequency of Operation
40 kHz (fixed)
Hold-Up Time
16 ms (115 VAC input), 32 ms (230 VAC input), minimum, at full load
Humidity
Operating:0 to 95%, non-condensing; Storage:0 to 95%, non-condensing
Input Line Frequency
47-440 Hz (50/60 Hz, nominal)
Input Line Protection
MOV transient protected. Input line fuse on-board. Replace the input line fuse with the same type and rating; Recommended:2A/250V slow blow fuse
Input Voltage
Universal input voltage range, 85-265 VAC single phase or 100-370 VDC
Mean Time Between Failures
>175,000 hours,calculated using the parts stress method in MIL-HDBK 217F (ground benign, TA equals +25°C)
Noise, Ripple and Spike
1% peak-to-peak, maximum
Output Power De-Rating
De-rate output power and current linearly 2%/°C from +50°C to +70°C
Output Voltage Adjust
Primary output adjustable ±5%; Auxiliary outputs fixed
Over-Voltage Protection
Primary output only (120% of rated output voltage, typical)
Overload Protection
Power-limit circuit
Short-Circuit Protection
Continuous
Soft Start
Standard on all models
Temperature
Operating:-20°C to +70°C; Storage:-40°C to +85°C
Temperature Coefficient
±0.05%/°C over the entire operating temperature range
Transient Response
4 ms recovery to within 1% of the regulation band with no more than 5% deviation
Features
- 0% Minimum Load Requirement—All Outputs
- 65W Continuous Output Power—Convection Cooled
- 85-265 VAC Universal Input Models
- CE Mark: UL/CSA/EN60950 Approvals
- Dual and Triple Output Models
- EN55022/FCC Class B Input Line Filter
- Low-Profile and Standard Height Formats
- Minimum 175,000-Hour MTBF
- Over-Current/Short-Circuit Protection
Datasheet
Extracted Text
65W OPEN-FRAME SWITCHING POWER SUPPLIES ✔ Dual and Triple Output Models ✔ Low-Profile and Standard Height Formats ✔ 65W Continuous Output Power—Convection Cooled ✔ 85-265 VAC Universal Input Models ✔ CE Mark: UL/CSA/EN60950 Approvals ✔ EN55022/FCC Class B Input Line Filter ✔ 0% Minimum Load Requirement—All Outputs ✔ Over-Current/Short-Circuit Protection ✔ 2-Year Warranty ✔ Minimum 175,000-Hour MTBF CHARACTERISTICS Input Voltage.............................Universal input voltage range, 85- Output Current Output 265 VAC single phase or 100-370 Output Voltage Min. Nom. Max. Voltage Line Load Cross- VDC. Model Output (V) (A) (A) (A) Tol. Reg. Reg. Reg. Input Line Frequency ................47-440 Hz (50/60 Hz, nominal). Input Line Protection.................MOV transient protected. Input line AC-DC Duals 85-265 VAC Input fuse on-board. Replace the input FLU2-65-2AD V1 +5 0.00 4.00 5.00 1.0% 0.2% 0.5% — line fuse with the same type and rat- V2 +15 0.00 4.00 5.00 5.0% 0.5% 5.0% 4.0% ing. Recommended: 2A/250V slow- FLU2-65-3AD V1 +5 0.00 8.00 8.50 1.0% 0.2% 0.5% — blow fuse. V2 +24 0.00 1.25 2.50 5.0% 0.5% 5.0% 4.0% EMI Filter...................................Standard. Performance surpasses AC-DC Triples 85-265 VAC Input conducted EMI requirements of EN55022/FCC Class B by 10 dB, typ. LPU3-65-5AD V1 +5 0.00 5.00 6.00 1.0% 0.2% 0.5% — V2 +12 0.00 1.70 3.00 5.0% 0.5% 3.0% 4.0% Continuous Output Power.........65W, maximum. V3 -12 0.00 1.70 3.00 5.0% 0.5% 4.0% 4.0% Output Voltage Adjust ...............Primary output adjustable ±5%. Auxiliary outputs fixed. LPU3-65-6AD V1 +5 0.00 5.00 6.00 1.0% 0.2% 0.5% — V2 +15 0.00 1.30 2.00 5.0% 0.5% 3.0% 4.0% Efficiency...................................65%, minimum, 115 or 230 VAC V3 -15 0.00 1.30 2.00 5.0% 0.5% 4.0% 4.0% input, full load conditions. Hold-Up Time............................16 ms (115 VAC input), 32 ms (230 FLU3-65-6AD V1 +5 0.00 5.00 6.00 1.0% 0.2% 0.5% — V2 +15 0.00 1.30 2.00 5.0% 0.5% 3.0% 4.0% VAC input), minimum, at full load. V3 -15 0.00 1.30 2.00 5.0% 0.5% 4.0% 4.0% Overload Protection ..................Power-limit circuit. Short-Circuit Protection.............Continuous. Over-Voltage Protection............Primary output only (120% of rated output voltage, typical). Soft Start...................................Standard on all models. Design Topology .......................Flyback converter with current-mode control. Frequency of Operation ............40 kHz (fixed). Electrical Strength/Isolation......5300 VDC, input-to-output for one minute. (See Note 1). Noise, Ripple and Spike ...........1% peak-to-peak, maximum. (Note 4.) Transient Response..................4 ms recovery to within 1% of the regulation band with no more than 5% deviation. Temperature Range ..................-20°C to +70°C. Output Power De-Rating...........De-rate output power and current linearly 2%/°C from +50°C to +70°C. Temperature Coefficient............±0.05%/°C over the entire operating temperature range. Relative Humidity......................0 to 95%, non-condensing. Altitude ......................................0 to 10,000 feet. Cooling......................................Convection cooling is adequate. Moving air is recommended for oper- ation in a confined area. Storage Temperature ................-40°C to +85°C. Storage Humidity ......................0 to 95%, non-condensing. Mean Time Between Failures ...>175,000 hours,calculated using the parts stress method in MIL-HDBK 217F (ground benign, T = +25°C). A POWER 152 Will Drive · Canton, MA 02021 USA · Phone 781-828-6216 · Fax 781-830-1155 · Email power@nidec.com · http://www.nidec.com GENERAL Rev. PG/ABBB 30 65W OPEN-FRAME SWITCHING POWER SUPPLIES FLU2-65 SERIES A. Dimensions shown are in inches. B. Tolerances = 0.00 ±0.01 inch. 0.000 ±0.005 inch. C. P1 input connectors are Molex 26-62-4030. The mating connector combines Molex housing 43061-0003 and crimp terminal 08-70-1030. D. P2 output connectors are Molex 26-60-4100. The mating connector combines the Molex housing 43061-0010 and the Molex crimp ter- minal 08-70-1030. Notes 1. Electrical strength/isolation is 2200 VDC from the input of the sup- ply to ground for 60 seconds. 2. All measurements are made directly at the power supply terminals. 3. Peak-to-peak and RMS metering equipment must have a 20 MHz frequency response with probes and cables that maintain a frequen- cy response of 20 Hz to 20 MHz. Output ripple and spikes are measured directly at the output terminals of the power supply with a 0.1 µF ceramic capacitor. The probe ground band must make direct contact with the output return or the common terminal of the power supply to prevent erroneous noise measurements. 4. Output voltage tolerance is measured under nominal load current conditions specified for the power supply. 5. Line regulation is measured under nominal load conditions as the input voltage is varied from 85 to 265 VAC (ac-input models) or from 36 to 75 VDC (dc-input models). 6. Load regulation is measured at 115 VAC or 230 VAC input. The output under test is brought to 60% of nominal load; load current is then varied +40%/-30% of nominal while other outputs are held at nominal load conditions. 7. Cross-regulation is tested by changing the load on the primary out- put from 50% to 100% of nominal load while measuring the voltage Pin-Out change on the auxiliary output under test. 8. The FLU2-65 and FLU3-65 series are approved to UL1950 (File LPU3-65 E140439), and CAN/CSA22.2 No. 234 (File LR52335). The FLU3- 65 series is approved to EN60950/IEC950/DIN VDE 0805 (TÜV Pin FLU2-65 FLU3-65 Licenses R9071576 and R9071575), as is FLU2-65-3AD (TÜV 1 Comm V1 License R0097629). 2 Comm V1 3V2 V1 4V2 V1 5 Comm V1 Comm 6 Comm V1 Comm 7 Comm V2 Comm 8V1 V2 9 V1 V3 Comm 10 V1 V3 11 N/A N/A 12 N/A N/A LPU3-65, FLU3-65 SERIES A. Dimensions shown are in inches. B. Tolerances = 0.00 ±0.01 inch. 0.000 ±0.005 inch. C. P1 input connectors are Molex 26-60-4051. The mating connector combines Molex housing 43061-0005 and Molex crimp terminal 08-70-1030. D. P2 output connectors are Molex 26-60-4120. The mat- ing connector combines Molex housing 43061-0012 and Molex crimp terminal 08-70-1030. POWER 152 Will Drive · Canton, MA 02021 USA · Phone 781-828-6216 · Fax 781-830-1155 · Email power@nidec.com · http://www.nidec.com GENERAL Rev. PG/ABBB 31
Frequently asked questions
What makes Elite.Parts unique?

What kind of warranty will the FLU2-65-3AD have?

Which carriers does Elite.Parts work with?

Will Elite.Parts sell to me even though I live outside the USA?

I have a preferred payment method. Will Elite.Parts accept it?

Why buy from GID?

Quality
We are industry veterans who take pride in our work

Protection
Avoid the dangers of risky trading in the gray market

Access
Our network of suppliers is ready and at your disposal

Savings
Maintain legacy systems to prevent costly downtime

Speed
Time is of the essence, and we are respectful of yours
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods