Elite.Parts chervon right Manufacturers chervon right A chervon right AULT / SL POWER chervon right FDA2-200-2CD
About product Datasheet FAQ

AULT / SL POWER FDA2-200-2CD

Description

200W AC/DC Switch-Mode Power Supply

Part Number

FDA2-200-2CD

Price

Request Quote

Manufacturer

AULT / SL POWER

Lead Time

Request Quote

Category

PRODUCTS - F

Datasheet

pdf file

FDA1-200-1CD.pdf

158 KiB

Extracted Text

POWER GENERAL FDA200 Series SINGLE, DUAL, TRIPLE OUTPUT SWITCHING POWER SUPPLIES — Active Power Factor Correction, Up to 200W Output, Rugged Low-Profile Package — Features 3.3V and 5V Singles · 3.3/5V, 3.3/12V, and 5/12V Duals · 3.3/5/12V Triple with N+1, Current Share · Continuous Output Ratings to 200W · Universal AC Input · EN60555-2 (Power Factor) Compliant · EN55022/FCC Class B Input Filter · EN61000-4 EMC/ESD Immunity · EN61000-3-2 Harmonic Current Limits · Remote Sense · TTL-Compatible Output Failure Warning · (Single Output, Dual Output Models) TTL-Compatible Remote On/Off · (Triple Output Model) Over-Voltage/Short-Circuit/Overload Protection · Thermal Protection · 7.5 ✕ 4.5 ✕ 1.47” U-Channel Chassis with Cover · 2-Year Warranty · FDA200 Characteristics Input Voltage Range........................................ 85-265 VAC (120/240 VAC, nominal). Input Line Frequency ...................................... 47-63 Hz (50/60 Hz, nominal). Input Current ................................................... 3.5A, maximum. In-Rush Current............................................... 50A, peak, at TA = +25°C. Input Line Protection ....................................... MOV transient protected. Input line fuse provided on-board. (See Note 3.) EMI Suppression Filter.................................... Standard; performance better than the requirements of con- ducted emissions standards EN55022/FCC Class B. Continuous Output Power............................... Models FDA1-200-1BD and FDA2-200-1BD, 165W, maxi- mum. Models FDA1-200-2BD, FDA2-200-2BD, and FDA3- 200-1BD, 200W, maximum. Turn-On Delay................................................. 0.8 seconds, maximum. Output Rise Time ............................................ 50 ms, maximum. Turn-On Overshoot ......................................... None. Design Topology ............................................. Forward converter operating under current-mode control. Frequency of Operation .................................. 67 kHz, fixed. Output Voltage Adjustment.............................. FDA1-200 and FDA2-200, all outputs adjustable ±5%. FDA3-200, outputs V1 and V2 adjustable ±5%; V3 fixed. Short-Circuit Protection................................... Continuous, cycle-by-cycle current limiting, all outputs; hiccup mode, automatic recovery. POWER GENERAL A Division of Nidec America Corporation 152 Will Drive · Canton, MA 02021 USA · Phone 781-828-6216 · Fax 781-830-1155 · E-Mail power@nidec.com · http://www.nidec.com POWER GENERAL FDA200 Series FDA200 Characteristics (Continued) Thermal Protection.......................................... +120°C critical component cutoff; automatic recovery. Over-Voltage Protection.................................. Latched OVP shutdown; input OFF/ON reset required. FDA1-200 and FDA2-200: Output V1, 110% to 130% of nominal. Output V2, 120% to 140% of nominal. FDA3-200: Output V1, 110% to 130% of nominal. Output V2, 110% to 130% of nominal. Output V3, 120% to 140% of nominal. Efficiency......................................................... FDA1-200 & FDA2-200, 78%, typical, at 120 VAC input, full load conditions; 80%, typical, at 240 VAC input, full load. FDA3-200, 76%, typical, at 120 VAC input, full load condi- tions; 78%, typical, at 240 VAC input, full load. Output-Fail Warning........................................ FDA1-200 and FDA2-200 models: TTL-compatible; an active LOW signal, 16 ms, minimum, before loss of regulation. Output DISABLE............................................... FDA3-200: TTL-compatible; all outputs disabled with connec- tor J4 pins shorted, or with voltage across them 0.8V or less; outputs enabled with connector J4 pins open, or with voltage across them 2.4V or more. Maximum voltage across connec- tor J4 pins = 60V. Electromagnetic Immunity............................... Meets the Electrostatic Discharge Immunity requirements of EN61000-4-2 (IEC801-2) at Level 4. Meets the Radiated Fields Immunity standards of EN61000-4- 3 (IEC801-3) at Level 3. Shock Immunity .............................................. Operating unit withstands triple 5g shocks (11 ms duration) on X, Y and Z axes without negative effect on performance. Vibration Immunity .......................................... Unpowered unit withstands 1.5g vibration (5.5 to 200 Hz cycling over an 84-minute period, per Mil Std 810C, Method 514) on X, Y, Z axes without damage. Transient Response........................................ 3 ms, maximum, recovery time to within 1% of the regulation window (150 mV peak deviation) after a step load change of 10A, maximum, at a slew rate of 0.1 A/µs. Hi-Pot Isolation................................................ 4300 VDC, input-to-output, for 60 seconds (Note 4). Operating Temperature Range ....................... 0°C to +50°C. Forced air cooling (100 LFM, minimum) is required. Temperature De-Rating................................... 2.5W/°C above +50°C to a maximum of +70°C. Temperature Coefficient.................................. ±0.04%/°C over the operating temperature range. Relative Humidity............................................ 0% to 95%, non-condensing. Altitude ............................................................ 0 to 10,000 feet. Storage Temperature Range........................... -20°C to +85°C. Storage Humidity ............................................ 0% to 95%, non-condensing. Mean Time Between Failures ......................... >165,000 hours (Note 12). -2- POWER GENERAL FDA200 Series Electrical Characteristics Output Current Output Initial Ripple 5 Output Voltage Min. Nom. Max. Voltage Setting & Noise Line Load Cross- Model Number Output (V) (A) (A) (A) Tolerance Tolerance (mVpp) Regulation Regulation Regulation FDA1-200-1CD V1 3.3 0 50 50 ±3% ±1.0% 100 ±0.2% ±1.0% — FDA1-200-2CD V1 5.0 0 40 40 ±3% ±1.0% 100 ±0.2% ±1.0% — FDA2-200-1CD V1 3.3 0 40 50 ±3% ±1.0% 100 ±0.2% ±1.0% — V2 +5.0 0 5.0 6.0 ±5% ±2.0% 100 ±0.5% ±3.0% ±3.0% FDA2-200-2CD V1 5.0 0 30 40 ±3% ±1.0% 100 ±0.2% ±1.0% — V2 +12 0 4.0 5.0 ±5% ±2.0% 100 ±0.5% ±3.0% ±3.0% 9 FDA3-200-1CD V1 5.0 3.0 22 40 ±3% ±1.0% 100 ±0.3% ±1.0% — V2 3.3 0 22 40 ±3% ±1.0% 100 ±0.3% ±1.0% ±2.0% V3(ISO) 12 0 1.0 1.0 ±3% ±3.0% 100 ±0.3% ±1.0% ±2.0% Notes: 1. All measurements are at nominal input, nominal load and +25°C, unless otherwise specified. 2. All measurements are made directly at the terminals of the power supply. 3. Replace the input line fuse with the same type and rating. Recommended: 4A/250V slow-blow fuse. 4. High-pot isolation is 2200 VDC from the input of the power supply to ground for 60 seconds. 5. Ripple and noise figures shown in the Electrical Characteristics table are maximum values. 6. Peak-to-peak and RMS metering equipment must have a 20 MHz response with probes and cables that maintain a frequency response of 20 Hz to 20 MHz. Output ripple and spikes are measured directly at the output terminals of the power supply across a 0.1 µF ceramic capacitor without use of the probe ground. The probe ground must make contact with the output return to prevent erroneous noise measurements. 7. Output voltage tolerance is the total maximum variation from rated output, including the initial setting tolerance, line and load regulation variations, and cross-regulation swings. 8. Line regulation is measured under full load conditions as the input voltage is varied from 90 to 250 VAC. 9. Minimum current required to meet load regulation characteristic on V2 and V3 outputs. 10. Load regulation is measured at 120 VAC or 240 VAC input. The output under test is brought to 60% of full load. The load current is then varied ±40% of its maximum rating while the other outputs are held at full load conditions. 11. Cross-regulation is tested by changing the load on the V1 output from 10% to 100% of full load while measuring voltage change on the auxiliary output. 12. MTBF is calculated using the parts stress method in MIL-HDBK 217F (ground benign, T = +25°C). A Conducted EMI EN55022 Class B EN55022 Class B FCC Class B FCC Class B FDA1-200-1BD: V = 120 VAC, Line-to-Ground FDA1-200-1BD: V = 240 VAC, Line-to-Ground in in -3- POWER GENERAL FDA200 Series Mechanical Outline and Terminal Configuration FDA1-200 and FDA2-200 Models #8 HEX NUT (3 PL) SCREW PH SLOT (3 PL) 8-32 x 0.075 LONG V1 PWR GOOD 3.250 #8 FLAT WASHER (3 PL) 2.000 COMMON #8 KEPS HEX NUT (3 PL) 0.500 V2 V1 J2 J3 DS1 PWR FAIL COMM R65 R49 -V1 SENSE +V1 SENSE T1 7.50 V1 ADJ 6.000 C12 L8 C11 V2 ADJ J1 0.450 0.25 0.050 0.250 CUSTOMER CHASSIS 1.47 MOUNTING 4 PL (NOTE 3) 0.350 1.300 3.800 DIMENSION NOTES: 4.50 1. Dimensions shown are in inches. 2. Tolerances = 0.00 ±0.03 0.000 ±0.015. 3. Chassis mounting inserts are PEM F-632-2. 4. Approximate unit weight: L N G FDA1-200 = 29 oz. (822g). FDA2-200 = 30 oz. (851g). 5. The output and output common studs, and associat- ed hardware, are designed for use with AMP 52197 or an equivalent connector. 6. The V1 Sense and Power-Fail connectors are AMP 640456-2. The mating connector combines AMP housing 770602-2 and crimp terminal 770666-1. -4- LINE NEUTRAL GROUND POWER GENERAL FDA200 Series Mechanical Outline and Terminal Configuration FDA3-200 #8 HEX NUT (3 PL) SCREW PH SLOT 8-32 x 3/4 LONG (3 PL) +V1 SENSE - V1 SENSE 3.250 #8 FLAT WASHER (3 PL) 2.000 #8 KEPS HEX NUT (3 PL) 0.500 V1 COMMON V2 V2 ADJ J5 J2 J3 J4 R6 COMMON R6 ENABLE +V2 SENSE -V2 SENSE T1 6.000 7.50 +V3 -V3 OUT C1 L8 C1 V1 ADJ J1 0.450 0.250 0.050 0.250 1.47 CUSTOMER CHASSIS MOUNTING 4 PL 0.350 (NOTE 3) 1.300 3.800 4.50 DIMENSION NOTES: 1. Dimensions shown are in inches. 2. Tolerances = 0.00 ±0.03 L N G 0.000 ±0.015. 3. Chassis mounting inserts are PEM F-632-2. 4. Approximate unit weight = 33 oz. (936g). 5. Output and output common studs, and associated hardware, are designed for use with AMP 52197 or an equivalent connector. 6. The V3 Output, V1 Sense, V2 Sense, and Output Disable connectors are AMP 640456-2. The mating connector combines AMP housing 770602-2 and crimp terminal 770666-1. Specifications are subject to change without notice. PG/ACAG LINE NEUTRAL GROUND

Frequently asked questions

What makes Elite.Parts unique?

chervon down
At GID Industrial (Elite.Parts' parent company), we specialize in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

What kind of warranty will the FDA2-200-2CD have?

chervon down
Warranties differ by part and by which suppliers we use to procure it for you. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carriers does Elite.Parts work with?

chervon down
Elite.Parts can ship via FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Will Elite.Parts sell to me even though I live outside the USA?

chervon down
Absolutely! We are happy to serve customers regardless of location. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

I have a preferred payment method. Will Elite.Parts accept it?

chervon down
All major credit cards are accepted: Visa, MasterCard, Discover, and American Express. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

AULT / SL POWER FLU1-40-1AD OPEN-FRAME SWITCHING POWER SUPPLIES

product

AULT / SL POWER FLU1-40-2AD OPEN-FRAME SWITCHING POWER SUPPLIES

product

AULT / SL POWER FLU1-40-2AD OPEN-FRAME SWITCHING POWER SUPPLIES

product

AULT / SL POWER FLU2-40-5AD OPEN-FRAME SWITCHING POWER SUPPLIES

product

AULT / SL POWER FLU2-40-6AD OPEN-FRAME SWITCHING POWER SUPPLIES

product

AULT / SL POWER FLU2-40-7AD OPEN-FRAME SWITCHING POWER SUPPLIES