Altitude

0 to 10,000 feet

Continuous Output Power

150W, maximum

Cooling

Convection cooling is adequate. Moving air is recommended for operation in a confined area

Design Topology

Forward converter with current-mode control

Efficiency

70%, typical (115 or 230 VAC input)

Electrical Strength/Isolation

5300 VDC, input-to-output for one minute

EMI Filter

Standard. Performance surpasses conducted EMI requirements of EN55022/FCC Class B by 10 dB, typ

Frequency of Operation

65 kHz (fixed)

Hold-Up Time

16 ms at 115 VAC input, 32 ms at 230 VAC input, minimum at full load

Humidity

Operating:0 to 95%, non-condensing; Storage:0 to 95%, non-condensing

Input Current

3.5A, maximum

Input Line Frequency

47-440 Hz (50/60 Hz, nominal)

Input Line Protection

MOV transient protected. Input line fuse provided on-board

Input Voltage

Auto-ranging input, 90-265 VAC, single phase

Mean Time Between Failures

>165,000 hours

Noise, Ripple and Spike

2% peak-to-peak, maximum

Output Power De-Rating

De-rate output power & current linearly 2%/°C from +50°C to +70°C

Output Voltage Adjust

Primary output adjustable ±5%. Auxiliary outputs fixed

Over-Voltage Protection

Primary output only (120% of rated output voltage, typical)

Overload Protection

Power-limit circuit

Power-Fail Warning

Optional: TTL-compatible (logic 0, 4 ms, minimum, before loss of output)

Short-Circuit Protection

Continuous

Soft Start

Standard on all models. Prevents output overshoot and power transformer saturation at start-up

Temperature

Operating:-20°C to +70°C; Storage:-40°C to +85°C

Temperature Coefficient

±0.05%/°C over the entire operating temperature range

Transient Response

4 ms recovery to within 1% of the regulation band with no more than 5% deviation

Features

Datasheet

pdf file

FDA1-150-1BD.pdf

90 KiB

Extracted Text

150W LOW-PROFILE SWITCHING POWER SUPPLIES IN U-CHANNEL CHASSIS ✔ Single and Dual Output Models ✔ 150W Continuous Output Power ✔ 1.38-Inch Overall Height ✔ 90-265 VAC Auto-Ranging Input ✔ UL1950/CSAC22.2-950/EN60950 Standards ✔ EN55022/FCC Class B Input Line Filter ✔ 0% Minimum Load Requirement ✔ Remote Load Sensing ✔ Over-Voltage/Over-Current/Short-Circuit Protection ✔ Optional Power-Fail Warning ✔ 2-Year Warranty ✔ Minimum 165,000-Hour MTBF CHARACTERISTICS Input Voltage.............................Auto-ranging input, 90-265 VAC, sin- gle phase. Output Current Output Input Line Frequency ................47-440 Hz (50/60 Hz, nominal). Output Voltage Min. Nom. Max. Voltage Line Load Cross- Input Current.............................3.5A, maximum. Model Output (V) (A) (A) (A) Tol. Reg. Reg. Reg. Input Line Protection.................MOV transient protected. Input line fuse provided on-board (Note 1). AC-DC Singles 90-265 VAC Input EMI Filter...................................Standard. Performance surpasses FDA1-150-1BD V1 3.3 0.00 45.0 45.0 1.0% 0.2% 0.5% — conducted EMI requirements of FDA1-150-2BD V1 5.0 0.00 30.0 30.0 1.0% 0.2% 0.5% — EN55022/FCC Class B by 10 dB, typ. FDA1-150-3BD V1 12 0.00 12.5 12.5 1.0% 0.2% 0.5% — Continuous Output Power.........150W, maximum. FDA1-150-4BD V1 15 0.00 10.0 10.0 1.0% 0.2% 0.5% — Output Voltage Adjust ...............Primary output adjustable ±5%. FDA1-150-5BD V1 24 0.00 6.25 6.25 1.0% 0.2% 0.5% — Auxiliary outputs fixed. Efficiency...................................70%, typical (115 or 230 VAC input). FDA1-150-7BD V1 48 0.00 3.13 3.13 1.0% 0.2% 0.5% — Hold-Up Time............................16 ms at 115 VAC input, 32 ms at AC-DC Duals 90-265 VAC Input 230 VAC input, minimum at full load. Overload Protection ..................Power-limit circuit. FDA2-150-1BD V1 +5 0.00 20.0 25.0 1.0% 0.3% 1.0% — Short-Circuit Protection.............Continuous. V2 +12 0.00 4.00 5.00 3.0% 0.5% 4.0% 4.0% Over-Voltage Protection............Primary output only (120% of rated FDA2-150-2BD V1 +5 0.00 20.0 25.0 1.0% 0.3% 1.0% — output voltage, typical). V2 +15 0.00 3.00 4.00 3.0% 0.5% 4.0% 4.0% Soft Start...................................Standard on all models. Prevents FDA2-150-3BD V1 +5 0.00 20.0 25.0 1.0% 0.3% 1.0% — output overshoot and power trans- V2 +24 0.00 2.00 2.50 3.0% 0.5% 4.0% 4.0% former saturation at start-up. Design Topology .......................Forward converter with current-mode control. Frequency of Operation ............65 kHz (fixed). Electrical Strength/Isolation......5300 VDC, input-to-output for one minute. (Note 2.) Noise, Ripple and Spike ...........2% peak-to-peak, maximum. (See Note 4.) Model Selection Guide Transient Response..................4 ms recovery to within 1% of the 1- 150 -1 B D 1 S FDA regulation band with no more than 5% deviation. Power-Fail Warning...................Optional: TTL-compatible (logic 0, 4 Series Power Fail Warning ms, minimum, before loss of output). (Optional) Number of Temperature Range ..................-20°C to +70°C. Outputs Output Power De-Rating...........De-rate output power and current Terminations Output Power linearly 2%/°C from +50°C to +70°C. 1=Screw Terminals (W) Temperature Coefficient............±0.05%/°C over the entire operating 2=Quick Disconnect temperature range. Output Voltage (Model) Relative Humidity......................0 to 95%, non-condensing. Altitude ......................................0 to 10,000 feet. Input Voltage Construction D=90-265 VAC Cooling......................................Convection cooling is adequate. B=U-Channel Moving air is recommended for oper- Chassis ation in a confined area. Storage Temperature ................-40°C to +85°C. Storage Humidity ......................0 to 95%, non-condensing. Mean Time Between Failures ...>165,000 hours (Note 5). POWER 152 Will Drive · Canton, MA 02021 USA · Phone 781-828-6216 · Fax 781-830-1155 · Email power@nidec.com · http://www.nidec.com GENERAL Rev. PG/ABBB 36 150W LOW-PROFILE SWITCHING POWER SUPPLIES IN U-CHANNEL CHASSIS FDA1-150/FDA2-150 A. Dimensions shown are in inches. B. Tolerances = 0.00 ±0.01 inch. 0.000 ±0.005 inch. C. The TB1 input connector is a three- position screw terminal. The alterna- tive, the P1 input connector (shown at A), is Molex 26-60-4051. The mating connector combines housing 43061- 0005 and Molex crimp terminal 08-70- 1030. D. The TB2 output connector is a six- position screw terminal. An alterna- tive (shown at B), the P2 output con- nector, is Molex 26-60-4120. The mating connector combines housing 43061-0012 and Molex crimp terminal 08-70-1030. E. The P4 Remote Sense/Power-Fail warning connector is Molex 22-23- 2041. The mating connector com- bines Molex housing 22-01-3047 and crimp terminal 08-50-0114. F. If Remote Sense is not used, tie +Sense to the appropriate VOUT termi- nation and tie -Sense to the appropri- Pin-Out ate Return or Common termination. G. If the Power-Fail warning option is not FDA1-150 FDA1-150 FDA2-150 FDA2-150 specified, the P4 pin designated +PF Pin TB2 P2 TB2 P2 is open-circuit. The pin designated -PF is always at Return/Common 1VOUT VOUT V2 V2 potential. 2 Return VOUT Common V2 3 Return Return Common Common 4 Return Return Common Common 5VOUT Return V1 Common 6VOUT Return V1 Common 7 N/A Return N/A Common 8 N/A Return N/A Common 9 N/A VOUT N/A V1 10 N/A VOUT N/A V1 11 N/A VOUT N/A V1 12 N/A VOUT N/A V1 Notes 5. MTBF is calculated using the parts stress method in MIL-HDBK 217F 1. Replace the input line fuse with the same type and rating. (ground benign, T = +25°C). Recommended: 4.0A/250V slow-blow fuse. A 6. Output voltage tolerance is measured under nominal load current condi- 2. Electrical strength/isolation is 2200 VDC from the input of the supply to tions specified for the power supply. ground for 60 seconds. 7. Line regulation is measured under nominal load conditions as the input 3. All measurements are made directly at the terminals of the supply. voltage is varied from 90 to 132 VAC and 180 to 265 VAC 4. Ripple is 1 percent, maximum. Ripple and spike is 2 percent, maximum. 8. Load regulation is measured at 115 VAC or 230 VAC input. The output Peak-to-peak and RMS metering equipment must have a 20 MHz fre- under test is brought to 60% of nominal load; load current and is then quency response with probes and cables that maintain a frequency varied ±40% of nominal while the other output is held at nominal load cur- response of 20 Hz to 20 MHz. rent conditions. Output ripple and spikes are measured directly at the output terminals of 9. Cross-regulation is tested by changing the load on the primary output the power supply with a 0.1 µF ceramic capacitor. The probe ground from 50% to 100% of nominal load while measuring the voltage change band must make direct contact with the output return or the common ter- on the auxiliary output under test. minal of the power supply to prevent erroneous noise measurements. POWER 152 Will Drive · Canton, MA 02021 USA · Phone 781-828-6216 · Fax 781-830-1155 · Email power@nidec.com · http://www.nidec.com GENERAL Rev. PG/ABBB 37

Frequently asked questions

What makes Elite.Parts unique?

chervon down
At GID Industrial (Elite.Parts' parent company), we specialize in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

What kind of warranty will the FDA2-150-2BD have?

chervon down
Warranties differ by part and by which suppliers we use to procure it for you. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carriers does Elite.Parts work with?

chervon down
Elite.Parts can ship via FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Will Elite.Parts sell to me even though I live outside the USA?

chervon down
Absolutely! We are happy to serve customers regardless of location. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

I have a preferred payment method. Will Elite.Parts accept it?

chervon down
All major credit cards are accepted: Visa, MasterCard, Discover, and American Express. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

AULT / SL POWER FLU1-40-1AD OPEN-FRAME SWITCHING POWER SUPPLIES

product

AULT / SL POWER FLU1-40-2AD OPEN-FRAME SWITCHING POWER SUPPLIES

product

AULT / SL POWER FLU1-40-2AD OPEN-FRAME SWITCHING POWER SUPPLIES

product

AULT / SL POWER FLU2-40-5AD OPEN-FRAME SWITCHING POWER SUPPLIES

product

AULT / SL POWER FLU2-40-6AD OPEN-FRAME SWITCHING POWER SUPPLIES

product

AULT / SL POWER FLU2-40-7AD OPEN-FRAME SWITCHING POWER SUPPLIES