AULT / SL POWER CPA2-65

Description
65W AC/DC Switch-Mode Power Supply
Part Number
CPA2-65
Price
Request Quote
Manufacturer
AULT / SL POWER
Lead Time
Request Quote
Category
PRODUCTS - C
Datasheet
Extracted Text
What’s New 65W DUAL OUTPUT SWITCHING POWER SUPPLIES ✔ Economical, Full-Feature Models ✔ 2 Outputs: +5 and +12 VDC ✔ 85-265 VAC Universal Input or 38-60 VDC Input ✔ Convection/Conduction Cooled ✔ No Minimum Load Requirements ✔ CE Mark: UL/CSA/EN Safety ✔ EN55022/FCC Class B Input Filter ✔ EN61000-4 EMC/ESD Immunity ✔ Over-Voltage, Short-Circuit/Overload Protection ✔ 5.9” ✕ 3.0” ✕ 1.3” Open-Frame or 6.2” ✕ 3.2” ✕ 1.5” Chassis and Cover ✔ Input Connector IEC320 or 3-Pin Quick-Disconnect ✔ Eight-Wire Output Harness ✔ 2-Year Warranty ✔ Minimum 450,000-Hour MTBF Output Current Output CHARACTERISTICS Output Voltage Min. Nom. Max. Voltage Line Load Cross- Model Output (V) (A) (A) (A) Tol. Reg. Reg. Reg. Input Voltage.............................CPA2-65: 85-265 VAC single phase AC-DC Dual 85-265 VAC Input (120/240 VAC nominal) or 100-370 VDC. CPD2-65: 38-60V VDC (48V CPA2-65 V1 +5 0.00 10 10 0.5% 0.2% 2.0% — V2 +12 0.00 1.0 1.0 3.0% 1.0% 5.0% 3.0% nominal). Input Line Frequency ................CPA2-65: 47-440 Hz. DC-DC Dual 38-60 VDC Input Input Current.............................CPA2-65: 1.8A, maximum. CPD2- CPD2-65 V1 +5 0.00 10 10 0.5% 0.2% 2.0% — 65: 2.75A, maximum. V2 +12 0.00 1.0 1.0 3.0% 1.0% 5.0% 3.0% In-Rush Current ........................CPA2-65: 60A, peak, at TA = +25°C, Vin = 265 VAC. CPD2-65: 60A, peak, at TA = +25°C, VIN = 60 VDC. CHARACTERISTICS Input Line Protection.................CPA2-65: MOV transient protection; input line fuse provided on-board. Design Topology .......................Flyback converter with current-mode CPD2-65: Dual input line fuses pro- control. vided on board. (Note 1.) Frequency of Operation ............40 kHz (fixed). Turn-On Delay...........................1 second, maximum, both outputs. Electrical Strength/Isolation......5300 VDC, input-to-output for one EMI Filter...................................Standard, performance better than minute. (Note 3.) the conducted EMI requirements of EN55022/FCC Class B. Noise and Ripple ......................2% peak-to-peak, maximum. (See Note 3.) Continuous Output Power.........65W, maximum. Temperature Range ..................-20°C to +70°C. Output Voltage Adjust ...............Output V1 is adjustable ±10%. Output V2 is fixed. Output Power De-Rating...........De-rate output power and current lin- early 2%/°C from +50°C to +70°C. Output Rise Time ......................100 ms, maximum, both outputs. Temperature Coefficient............Output V1: ±0.02%/°C over the Efficiency...................................65%, minimum (nominal input line entire operating temperature range. voltage and full load conditions). Output V2: ±0.05%/°C over the Hold-Up Time............................16 ms (115 VAC input), 32 ms (230 entire operating temperature range. VAC input), minimum, at full load. Relative Humidity......................0 to 95%, non-condensing. Overload Protection ..................Power-limit circuit. Altitude ......................................0 to 10,000 feet. Short-Circuit Protection.............Continuous, cycle-by-cycle current Cooling......................................Convection cooling is adequate. limiting, both outputs; foldback/hic- When operating in a confined area, cup mode, automatic recovery. (See moving air is recommended. Note 2.) Storage Temperature ................-40°C to +85°C. Over-Voltage Protection............Crowbar type, V1 only: 6.7V, maxi- mum, automatic recovery. Storage Humidity ......................0 to 95%, non-condensing. Power Factor.............................65%, minimum. Mean Time Between Failures ...>450,000 hours (Note 8). POWER 152 Will Drive · Canton, MA 02021 USA · Phone 781-828-6216 · Fax 781-830-1155 · Email power@nidecpg.com · http://www.nidec.com GENERAL 04 What’s New 65W DUAL OUTPUT SWITCHING POWER SUPPLIES CPA2-65-1AD CPA2-65-1AD CPA2-65-1CD A. Dimensions shown are in inches. B. Tolerances = 0.00 ±0.01 inch. 0.000 ±0.005 inch. C. For the open-frame model CPA2-65- 1AD, the P1 input connector is Molex 26-62-4050. The mating connector com- bines Molex housing 26-03-4050 and crimp terminal 08-52-0113. For the enclosed model, CPA2-65-1CD, the input connector P1 is IEC320-C14. D. The output connector P2 combines Molex housing 09-50-8083 and Molex crimp terminals 08-58-0187. Pin-Out Wire Pin Color Function 1 Black Common 2 Black Common 3 Red V1 4 Red V1 5 Black Common 6 Yellow V2 7 Black Common 8 Red V1 CPA2-65-1CD POWER 152 Will Drive · Canton, MA 02021 USA · Phone 781-828-6216 · Fax 781-830-1155 · Email power@nidecpg.com · http://www.nidec.com GENERAL 5 What’s New 65W DUAL OUTPUT SWITCHING POWER SUPPLIES CPD2-65-1AC A. Dimensions shown are in inches. B. Tolerances = 0.00 ±0.01 inch. 0.000 ±0.005 inch. C. The P1 input connector is Molex 26-60- 4020. The mating connector combines Molex housing 09-50-8023 and crimp terminal 08-50-0106. D. The output connector P2 combines Molex housing 09-50-8083 and Molex crimp terminals 08-58-0187. Pin-Out Wire Pin Color Function 1 Black Common 2 Black Common 3 Red V1 4 Red V1 5 Black Common 6 Yellow V2 7 Black Common 8 Red V1 Notes 1. Replace the input line fuses with the same types and rating. for CPD2-65 models is measured under full load conditions as the input Recommended: CPA2-65—2.0A/250V slow-blow fuse. voltage is varied from 38 to 60 VDC. CPD2-65—3.5A/250V slow-blow fuses. 6. Load regulation for CPA2-65 models is measured at 120 VAC or 240 2. Foldback/hiccup mode is used for overload protection; the overload limit VAC. Load regulation for CPD2-65 models is measured at 48 VDC. The for output V1 is 14.5A; the overload limit for output V2 is 2.8A. output under test is brought to 60%of full load; load current is then varied 3. Electrical strength/isolation is 2200 VDC from the input of the power sup- ±40% of full load while other output is held at full load condition. ply to ground for 60 seconds. 7. Cross-regulation is tested by changing the load on the V1 output from 4. Peak-to-peak and RMS metering equipment must have a 20 MHz fre- 50% to 100% of full load while measuring the voltage change on the aux- quency response with probes and cables that maintain a frequency iliary output under test. response of 20 Hz to 20 MHz. Output ripple and spikes are measured 8. MTBF is calculated using Bellcore TR-NWT-000332 (ground benign, TA = directly at the output terminals of the power supply with a 0.1 µF ceramic +40°C). capacitor. The probe ground band must make direct contact with the out- put return or common terminal to prevent erroneous noise measure- 9. CPA2-65-5509, CPA2-65-5520 and CPD2-65-5554 are approved to ments. UL1950 (File E140439) and CUL1950 (File E140439). CPA2-65-5509 5. Line regulation for CPA2-65 models is measured under full load condi- and CPA2-65-5520 are approved to EN60950 (TÜV License tions as the input voltage is varied from 85 to 265 VAC. Line regulation B970918781048). POWER 152 Will Drive · Canton, MA 02021 USA · Phone 781-828-6216 · Fax 781-830-1155 · Email power@nidecpg.com · http://www.nidec.com GENERAL 06
Frequently asked questions
What makes Elite.Parts unique?

What kind of warranty will the CPA2-65 have?

Which carriers does Elite.Parts work with?

Will Elite.Parts sell to me even though I live outside the USA?

I have a preferred payment method. Will Elite.Parts accept it?

What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods