Arcom APCI-RELAY8/IN8 Features eight opto-isolated inputs with 1500V input-to-output isolation, together with 8 changeover relay outputs rated to a maximum of 60 Watts

Part Number

APCI-RELAY8/IN8

Price

Request Quote

Manufacturer

ARCOM

Lead Time

Request Quote

Category

PCI-BUS »  DIGITAL I/O

Features

Datasheet

pdf file

Arcom-APCI-RELAY8-IN8-Relay-Output-datasheet1-1180092086.pdf

138 KiB

Extracted Text

J594 APCI-RELAY8/IN8 2192-09101-000-000 APCI-RELAY8/IN8 Introduction The APCI-RELAY8/IN8 is a 32-bit PCI local BUS board which provides 8 changeover relays and 8 opto isolated digital input signals. Each relay has a power rating of 60W (resistive load). This allows switching of voltages up to 48V DC (to meet low voltage directive) and currents of up to 1.0A. Features � 8 Changeover relays with power switching rating of 60W (resistive load) � Switching voltage up to 48V DC (to meet low voltage directive) and currents up to 1.0A � 8 Opto Isolated inputs with current limiting resistors � Opto input switching voltage 10V to 30V � Relay status readback register � N.O. and N.C. contacts provided at connector � Relay drivers disabled at power-up and reset � Link selectable debounce option on inputs � Board access LED � PCI 2.1 Compatible Bus interface � Plug and Play software compatible � Operating Temperature range 0 to +70C � Relay operating life 500,000 operations (DC Full load) � CE Compliant design � Power Consumption 60mA + 30mA per relay operating @ +5V � MTBF 323,293 hours (using generic figures from MIL-HDBK-217F at benign ground) Getting Started � Power down your PC system. � Install the board in a spare PCI Slot (See Installation for CE compliance). � Power up system with MSDOS. � Run APCI.EXE (supplied on the utility disk), this will search for the board and check I/O access. If this fails, check board is correctly l0cated. Warning This board contains C CM MO OS S devices which may be damaged by static electricity. Please ensure anti- static precautions are taken at all times when handling this board. If for any reason this board is returned to Arcom Control Systems, please ensure it is adequately packed to prevent damage during shipment. Page 1 2192-09101-000-000 J594 APCI-RELAY8/IN8 Operation PCI Bus Interface The PCI bus is a high speed alternative to ISA bus, it has been designed to overcome some of the limitations of ISA bus, and provide faster throughput for I/O intensive peripheral devices. PCI bus also supports Plug and Play configuration which allows the system software to allocate resources during initialisation helping to overcome resource conflicts, which might exist in a system. The APCI-RELAY8/IN8 uses a single chip PCI bus slave controller which is designed and manufactured by PLX Technology. This device has been designed to fully support the PCI 2.1 specification and provides plug and play software capabilities. During power-up initialisation the PCI BIOS will detect the card and assign a unique I/O address location and interrupt line. This ensures that there are no resource conflicts on the PCI bus. Multiple cards are supported through this mechanism without the need for address decode links. The PLX device contains a standard type 00H configuration space header. The table below shows the registers within this header which are required for configuration of the APCI-RELAY8/IN8. Configuration Space Header Offset Register Name Description Value 00-01H Vendor ID ID of PCI device manufacturer 10B5H (PLX Technology) 02-03H Device ID ID of PCI device 9050H 18-1BH Base Address Register I/O base address assigned to card 0000xxxxH 2C-2DH Subsystem Vendor ID ID of board manufacturer 13ABH (ARCOM) 2E-2FH Subsystem ID ID of Board 0594H(APCI-RELAY8/IN8) 3CH Interrupt Line Interrupt line assigned to device 0xH These registers can be accessed using PCI BIOS functions. Please contact Arcom control systems customer support team (Tel: 01223 412428) for a copy of the PCI BIOS Specification if required. Page 2 J594 APCI-RELAY8/IN8 2192-09101-000-000 Relays When the board is switched ON, all relays are in the normally closed position. To swicth a relay ON (i.e. change to normally open position) a logic �1� must be written to the corresponding bit in the relay output register. This will have no effect until a logic �1� is written to bit 0 of the relay enable register. For system initialisation, it is recommended that the output register is written with the required relay states before the relay enable bit is set. A relay status register has been incoporated in the design to enable reading of the relay outputs. If a bit in this register is set to logic �1� the corresponding relay is in the N.O position. Relay Configuration Opto Isolated Inputs The status of the opto isolated inputs can be read via the opto input register. If the input is switched ON (i.e. a voltage has been applied to the input line) the corresponding bit in this register is set to logic�0�. A voltage in the range 10-30V must be applied to the input to ensure it is switched ON. Each opto-isolated input has an optional debounce circuit which can be enabled/disabled via LK1. Opto Isolated Inputs Page 3 2192-09101-000-000 J594 APCI-RELAY8/IN8 I/O Map The APCI-RELAY8/IN8 uses two consecutive I/O address locations to access the onboard functions. The I/O base address is set by the PCI BIOS during initialisation (refer to the PCI BUS section of this manual for details). A PCI BIOS function call may be used to determine the base address once the system has been initialised. Multiple boards may be used in a system as each will be given a unique I/O address. Offset Register Name Read/Write Comments Bit Function 00 Relay Output Write Configure Relay Bit 0-7 for relay 0-7 Outputs �0� = relay NC contacts closed �1� = relay NO contacts closed 00 Relay Status Read Readback Status Bit 0-7 for relay 0-7 �0� = relay NC position �1� = relay NO position 01 Relay Enable Write Enable Relay latches Bit 0 �0� = all relays OFF (NC position) �1� = relays enabled. Bit 1-7 unused. 01 Opto Inputs Read Read Opto Inputs Bit 0-7 �0�=input ON �1�=input OFF Page 4 J594 APCI-RELAY8/IN8 2192-09101-000-000 Links Each opto-isolated input line has an optional debounce circuit which can be enabled/disabled via LK1. If a link is fitted the corresponding debounce circuit will be enabled. LK1 Position Opto Input bit A 0 B 1 C 2 D 3 E 4 F 5 G 6 H 7 Default Link Position Diagram User Configuration Record Diagram Page 5 2192-09101-000-000 J594 APCI-RELAY8/IN8 D-50 I/O Connector (PL1) Pin Assignments The pin assignments are listed with the pin number of the D-50 connector and also the pin number when a 50-way IDC ribbon cable is connected to the D-50. The pin assignments conform to the Arcom signal conditioning system (SCS) and may be connected to an external signal conditioning board. Ribbon Cable D-Type Ribbon Cable D-Type Pin No. Pin No. Function Pin No. Pin No. Function 1 1 N/C 26 42 N/C 2 34 Relay 1 common 27 26 Relay 6 common 3 18 Relay 1 NO 28 10 Relay 6 NO 4 2 Relay 1 NC 29 43 Relay 6 NC 5 35 N/C 30 27 N/C 6 19 N/C 31 11 N/C 7 3 Relay 2 common 32 44 Relay 7 common 8 36 Relay 2 NO 33 28 Relay 7 NO 9 20 Relay 2 NC 34 12 Relay 7 NC 10 4 N/C 35 45 N/C 11 37 N/C 36 29 N/C 12 21 Relay 3 common 37 13 Relay 8 common 13 5 Relay 3 NO 38 46 Relay 8 NO 14 38 Relay 3 NC 39 30 Relay 8 NC 15 22 N/C 40 14 N/C 16 6 N/C 41 47 Common -ve input (low bits) 17 39 Relay 4 common 42 31 +ve input bit 0 18 23 Relay 4 NO 43 15 +ve input bit 1 19 7 Relay 4 NC 44 48 +ve input bit 2 20 40 N/C 45 32 +ve input bit 3 21 24 N/C 46 16 +ve input bit 4 22 8 Relay 5 common 47 49 +ve input bit 5 23 41 Relay 5 NO 48 33 +ve input bit 6 24 25 Relay 5 NC 49 17 +ve input bit 7 25 9 N/C 50 50 Common -ve input (high bits) Page 6 J594 APCI-RELAY8/IN8 2192-09101-000-000 Installation for CE Compliance To maintain compliance with the requirements of the EMC directive (89/336/EEC), this product must be correctly installed. The PC system in which the board is housed must be CE compliant as declared by the manufacturer. The type of external I/O cable required can be chosen according to the notes below: 1. Remove the cover of the PC observing any additional instructions of the PC manufacturer. 2. Locate the board in a spare PCI slot and press gently but firmly into place. 3. Ensure that the metal bracket attached to the board is fully seated. 4. fit the bracket clamping screw and firmly tighten this on the bracket. Note:- Good contact of the bracket to the chassis is essential. 5. Replace the cover of the PC observing any additional instructions of the PC manufacturer. Cable Cable length 1 Metre or less : Ribbon cable satisfactory. Cable 1 Metre to 3 Meters : Commerial screened cable. > 3 Meters or noisy environment : Use fully screened cable with metal backshells e.g. Arcom CAB50CE The following standards have been applied to this product: BS EN50081-1 : 1992 Generic Emissions Standard, Residential, Commercial, Light Industry BS EN50082-1 : 1992 Generic Immunity Standard, Residential, Commercial, Light Industry BSEN55022 : 1995 ITE Emissions, Class B, Limits and Methods. Page 7 2192-09101-000-000 J594 APCI-RELAY8/IN8 Product Information F Fa ax x--o on n--D De em ma an nd d S Sy ys stte em m Full information about other Arcom products is available via the , (Telephone Numbers are listed below), or by contacting our W We eb bS Siit te e in the UK at: w ww ww w. .a ar rc co om m. .c co o. .u uk k , or in the US at: w ww ww w. .a ar rc co om mc co on nt tr ro olls s. .c co om m U Us se ef fu ul l C Co on nt ta ac ct t I In nf fo or rm ma at tiio on n C Cu us st to om me er r S Su up pp po or rt t S Sa alle es s Tel: +44 (0)1223 412 428 Tel: +44 (0)1223 411 200 Fax: +44 (0)1223 403 400 Fax: +44 (0)1223 410 457 E-mail: support@arcom.co.uk E-mail sales@arcom.co.uk or for the US E-mail icpsales@arcomcontrols.com U Un ni it te ed d K Ki in ng gd do om m U Un ni it te ed d S St ta at te es s F Fr ra an nc ce e G Ge er rm ma an ny y B Be el lg gi iu um m Arcom Control Systems Ltd Arcom Control Systems Inc Arcom Control Systems Kostenlose Infoline: Groen Nummer: Clifton Road 13510 South Oak Street Centre d�affaires SCALDY Tel: 0130 824 511 Tel: 0800 7 3192 Cambridge CB1 4WH, UK Kansas City MO 64145 USA 23 rue Colbert Fax: 0130 824 512 Fax: 0800 7 3191 Tel: 01223 411 200 Tel: 816 941 7025 7885 SAINT QUENTIN FoD: 0130 860 449 Fax: 01223 410 457 Fax: 816 941 0343 Cedex, FRANCE N Ne et th he er rl la an nd ds s FoD: 01223 240 600 FoD: 800 747 1097 Tel: 0800 90 84 06 I It ta al ly y Gratis 06 Nummer: Fax: 0800 90 84 12 NumeroVerde: Tel: 06022 11 36 FoD: 0800 90 23 80 FoD: 1678 73600 Fax: 06022 11 48 The choice of boards or systems is the responsibility of the buyer, and the use to which they are put cannot be the liability of Arcom Control Systems Ltd. However, Arcom�s sales team is always available to assist you in making your decision. ' 1997 Arcom Control Systems Ltd Arcom Control Systems is a subsidiary of Fairey Group Plc. Specifications are subject to change without notice and do not form part of any contract. All trademarks recognised. Arcom Control Systems Ltd operate a company-wide quality management system which has been certified by the British Standards Institution (BSI) as compliant with ISO9001:1994 Revision History Manual PCB Comments Issue A V1 Iss 2 980313 First released in this format. Page 8

Frequently asked questions

What makes Elite.Parts unique?

chervon down
At GID Industrial (Elite.Parts' parent company), we specialize in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

What kind of warranty will the APCI-RELAY8/IN8 have?

chervon down
Warranties differ by part and by which suppliers we use to procure it for you. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carriers does Elite.Parts work with?

chervon down
Elite.Parts can ship via FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Will Elite.Parts sell to me even though I live outside the USA?

chervon down
Absolutely! We are happy to serve customers regardless of location. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

I have a preferred payment method. Will Elite.Parts accept it?

chervon down
All major credit cards are accepted: Visa, MasterCard, Discover, and American Express. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

Arcom APCI-IB40 40-Channel Digital I/O & Counter Board