APPLETON ELECTRIC ELF90-50
Datasheet
Extracted Text
I I-20 Class I, Div. 1 and 2 45° and 90° Elbows: Groups A,B,C,D Class II, Div. 1 and 2 Explosionproof, Dust-Ignitionproof Groups E,F,G ® UNILETS for use with Threaded Metal Conduit. Class III Size Dimensions (A) Catalog Number NPT Threads Inches Inches (mm) Malleable Iron Aluminum 45° Female Elbows 1/2 1.19 (30.2) ELF45-50 ELF45-50-A 3/4 1.31 (33.3) ELF45-75 ELF45-75-A 1 1.56 (39.7) ELF45-100 1-1/4 1.69 (42.9) ELF45-125 1-1/2 2.00 (50.8) ELF45-150 ELF45-150-A 2 2.25 (57.2) ELF45-200 90° Female Elbows 1/2 1.50 (38.1) ELF90-50 ELF90-50-A 3/4 1.69 (42.9) ELF90-75 ELF90-75-A 1 1.81 (46.0) ELF90-100 ELF90-100-A 1-1/4 2.06 (52.4) ELF90-125 ELF90-125-A 90° Male and Female Elbows 1/2 1.50 (38.1) ELMF90-50 ELMF90-50-A 3/4 1.69 (42.9) ELMF90-75 ELMF90-75-A 1 1.81 (46.0) ELMF90-100 ELMF90-100-A 1-1/4 2.06 (52.4) ELMF90-125 90° Male Elbows 1/2 1.50 (38.1) ELM90-50 ELM90-50-A 3/4 1.69 (42.9) ELM90-75 ELM90-75-A 1 1.88 (47.6) ELM90-100 1/2 1.75 (44.5) ELMFL90-50 ELMFL90-50-A 3/4 2.25 (57.2) ELMFL90-75 ELMFL90-75-A 1 2.63 (66.7) ELMFL90-100 ELMFL90-100-A 1-1/4 3.31 (84.1) ELMFL90-125 1-1/2 3.50 (88.9) ELMFL90-150 2 4.00 (101.6) ELMFL90-200 Flexible/Swivel Elbows (Full 360°) Class I, Group D; Class II, Groups E,F,G; and Class III. 1/2 3.75 (95.3) UNAF50 3/4 4.38 (111.1) UNAF75 1 5.00 (127.0) UNAF100 Shaded area indicates items suitable for Class I, Groups A and B in addition to Class I, Groups C,D; Class II, Groups E,F,G; and Class III. Effective September, 2005 800-621-1506 Copyright 2005 www.appletonelec.com PAGE 20 I I-3 Unions, Sealing Fittings, Flexible Couplings, Elbows, Drain/Breather, Close-Up Plugs: Explosionproof ® UNILETS for Use with Threaded Metal Conduit and restrict the passage of gases and of malleable iron have triplecoat—(1) Features: All Fittings explosions in classified areas. zinc electroplate, (2) dichromate, and (3) Explosionproof, dust-ignitionproof. • epoxy powder coat, of steel have zinc Fiber Filler-makes dams around • Smooth, rounded integral bushing in • electroplate, of aluminum 1/2” thru 2” have and between all conductors to prevent each hub protects conductor insulation. natural finish and 2-1/2” thru 4” have epoxy sealing compound from leaking while Accurately tapped, tapered threads for powder coat. • being poured in its liquid state. tight, rigid joints and ground continuity. Sealing Fittings— EYSF/EYSM, ESUF/ • Features: Sealing Hubs ESUM, EYF/EYM,EYDM and EYD/EYS Features: Non-Expansion Unions ❹ UL Listed for use in hazardous ® of malleable iron and Grayloy -iron have ❶ Concentric ring interlocked design of ® locations when Kwiko A Sealing triple-coat—(1) zinc electroplate, (2) 1/2”, 3/4” and 1” sizes makes possible ® Compound or Crouse-Hinds Chico A dichromate, and (3) epoxy powder coat, of smaller diameter, allowing use in tight- Sealing Compound are used to make Almag 35 aluminum have epoxy powder er spaces. 1-1/4” and larger UNY sizes the seal. coat. have removable male nipple. Sealing Hubs—ES of malleable iron Features: Flexible Couplings • Choice of malleable iron or alumi- • have a triple-coat—(1) zinc electroplate, ❺ Heavy duty design resists mechani- num. (2) dichromate, and (3) epoxy powder cal abuse. Watertight. Features: Expansion Unions coat. Electrical conductivity equal to rigid • ❷ One-piece design eliminates need Flexible Couplings—EXGJH and EXLK conduit on a similar length basis—no • for disassembly during installation. natural finish. bonding jumper required. Telescoping cylinder within cylinder • Close-up Plugs—PLG of malleable iron Interior insulating liner protects con- • • design permits expansion or contraction. have a triple-coat—(1) zinc electroplate, ductors from abrasion under vibrating (2) dichromate, and (3) epoxy powder Standard or long types available. • conditions. coat; steel have zinc electroplate; alumi- Small external diameters—excellent • EXGJH—both end fittings are female, • num have natural finish. in restricted areas in wiring of pumps, each furnished with a removable male Bell Reducers—BR of malleable iron motors, and other equipment. • nipple. have a triple-coat—(1) zinc electroplate, Internal phosphor bronze “bonding • EXLK—female end fitting with union at • (2) dichromate, and (3) epoxy powder jumper” ring assures positive ground one end and a female end fitting with a coat; aluminum have natural finish. between telescoping cylinders. removable male nipple at the other end. Elbows—EL are malleable iron and • Features: Sealing Fittings Standard Materials have zinc electroplate; UNA are mal- ❸ Raintight construction. UNY and UNF (Non-Expansion) Unions, leable iron and have a triple-coat—(1) • Removable nipple in male sealing zinc electroplate, (2) dichromate, and 1/2” thru 1”: steel or aluminum. 1-1/4” • fitting may be used interchangeably in thru 6”: malleable iron or aluminum. (3) epoxy powder coat. top or bottom hub. UNY and UNF Expansion Unions: steel. Combination Drain/Breathers—ECDB • • are passivated stainless steel and have EYS—for sealing vertical conduit. • UNL Unions: malleable iron and steel. • a natural finish. Large opening for damming and filling. EYSF/EYSM, EYF/EYM and EYDM Seals: • Expanded Fill EYSEF/EYDEF— allow • malleable iron or Almag 35 aluminum. Options up to 40% conduit fill in compliance For ES Sealing Hubs, add suffix BLSG EYS, EYSEF/EYDEF, and ESUF/ESUM: • • with the National Electrical Code. for sealing gaskets and locknuts (pro- malleable iron. EYSF/EYSM—for sealing vertical con- vide a water and oil-tight connection). • ® EYD and EYS Seals: Grayloy -iron. • duit. Large opening for damming and fill- EXGJH and EXLK Couplings, 1/2” Compliances • ing. thru 2”: outer bronze braid, inner brass UL Standard 886 • ESUF/ESUM for sealing vertical • core with insulating liner; 2-1/2” thru Appleton malleable iron products or horizontal conduit. Pouring spout • 4”: outer stainless steel braid, inner conform to ASTM A47-77, Grade rotates 90° Removable cover provides stainless steel core with insulating 32510. which has the following proper- full access for damming 2-1/2” thru 4” liner. End Fittings: 1/2” thru 2”—brass; ties: tensile strength, 50,000 psi; yield, sizes have threaded cover openings 2-1/2” thru 4”—stainless steel. 32,000 psi; and elongation, 10%. for damming. PLG Close-Up Plugs: malleable iron, • Appleton aluminum products • EYF/EYM—close radius type for seal- • steel, or aluminum. are produced from a high strength ing vertical or horizontal conduit runs. BR Reducers: malleable iron or aluminum. copper-free (4/10 or 1% max.) alloy. • EYDM Drain Sealing Fittings—close • EL and UNA Elbows: malleable or cast Class I, Div. 1 & 2 and Class II, Div. • • radius type for sealing vertical conduit 1 & 2, if installed as follows: Unions, iron. runs. Access cover has drain valve for Elbows, Plugs, Flex. Couplings— ECDB Combination Drain/Breather: automatic draining of water accumula- • NEC 501-4 (a)(b); Seals—NEC 501-5 stainless steel. tion above the seal. (a)(b)(c)(d)(e) and NEC 502-5; Drains— ® Kwiko A sealing cement is a specially • Standard Finishes NEC 501-5(f). formulated water soluble powder. Mixed Unions—UNY,UNF and UNL (Non-Ex- • to the proper proportions, it is poured in pansion) and UNY and UNF (Expansion) sealing fittings and hardens to contain Effective September, 2005 800-621-1506 Copyright 2005 www.appletonelec.com PAGE 3
Frequently asked questions
What makes Elite.Parts unique?

What kind of warranty will the ELF90-50 have?

Which carriers does Elite.Parts work with?

Will Elite.Parts sell to me even though I live outside the USA?

I have a preferred payment method. Will Elite.Parts accept it?

What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods