Allen-Bradley 1762-IF4 4 Channel Analogue Input Module

Part Number

1762-IF4

Price

Request Quote

Manufacturer

ALLEN BRADLEY

Lead Time

Request Quote

Category

PROGRAMMABLE CONTROLLERS

Specifications

Analog Ranges

Voltage: ±10V, Current: 4…20 ma

Bus Current Draw, Max.

40 mA at 5V DC, 50 mA at 24V DC

Conducted Immunity (IEC 1000-4-6)

10V, 0.15…80 MHzT

Dimensions (HxWxD), Approx.

90 x 40 x 87mm (3.543 x 1.575 x 3.425 in.)¬

ESD Immunity (IEC 1000-4-2)

4 kV contact, 8 kV air, 4 kV indirect

Fast Transient Burst (IEC 1000-4-4)

2 kV, 5 kHz

Inputs/Outputs

4 differential inputs (bipolar)

Operating Altitude, Max.

2,000 m (6,561 ft)

Operating Humidity

5…95% (without condensation)

Operating Temperature

-20…65 °C (-4…149 °F) (on selected modules)

Overall Accuracy

±0.32% full scale at -20…65° C (-4…149° F)T , ±0.24% full scale at 25° C (77° F)

Radiated and Conducted Emissions

EN50081-2 Class A

Radiated Immunity (IEC 1000-4-3)

10V/m, 80-1000 MHz, 80% amplitude modulation, +900 MHz keyed carrier

Resolution Across Full Range

15 bits (bipolar)T

Shock, nonoperating

40 g panel mounted, 30 g DIN rail mounted

Shock, operating

30 g panel mounted, 20 g DIN-rail mounted

Shock, Relay Operation

7.5 g panel mounted, 5 g DIN rail mounted

Surge Immunity (IEC 1000-4-5)

2 kV common mode, 1 kV differential mode

Typical Update Period

130, 250, 290, 450, 540 ms (selectable)

Vibration, Operating

10…500 Hz, 5 g, 0.015 in peak-to-peak

Vibration, Relay Operation

2 g

Features

Datasheet

pdf file

Rockwell Automation=1761-sg001=datashee-1195018507t.pdf

9939 KiB

Extracted Text

MICROLOGIX PROGRAMMABLE CONTROLLERS SELECTION GUIDE BULLETIN 1761 - MicroLogix 1000 BULLETIN 1763 - MicroLogix 1100 BULLETIN 1762 - MicroLogix 1200 BULLETIN 1766 - MicroLogix 1400 BULLETIN 1764 - MicroLogix 1500 MicroLogix Programmable Controllers Overview 3 The MicroLogix family of controllers provides five levels of control. Small on size, big on MicroLogix Programmable performance, the MicroLogix 1000 controller offers control capabilities in an affordable, Controllers Overview compact package. The MicroLogix 1200 controller is small enough to fit in tight spaces, but powerful enough to accommodate a broad range of applications. Designed to grow as your needs grow, the MicroLogix 1500 controller helps you achieve high-level control in a variety of applications. The MicroLogix family’s newest members, the MicroLogix 1100 and 1400 controllers, further enhance the MicroLogix family by expanding the application coverage area while offering great new features at an affordable price. MicroLogix 1000 Controller Based on the architecture of the market-leading SLC 500 controller family, the MicroLogix 1000 controller brings high-speed, powerful instructions and flexible communication to applications that demand compact, cost-effective solutions. The MicroLogix 1000 controller is available in 10-point, 16-point, or 32-point digital I/O versions. Analog versions are also available with 20 digital I/O points, with 4 analog inputs (2 voltage and 2 current) and 1 analog output (configurable for either voltage or current). The analog I/O circuitry for the MicroLogix 1000 controller is embedded into the base controller, not accomplished through add-on modules: so, it provides very high-speed, cost-effective analog performance. The MicroLogix 1000 controller uses Rockwell Software RSLogix 500 and RSMicro programming software and shares a common instruction set with the MicroLogix and SLC 500 families of controllers. Publication 1761-SG001F-EN-P - March 2011 4 MicroLogix Programmable Controllers Overview Advantages for the MicroLogix 1000 Controllers Preconfigured 1 KB program and data memory to ease configuration (for example, preconfigured bit, integer, timers, and counters). Fast processing allows for typical throughput time of 1.5 ms for a 500-instruction program. Built-in EEPROM memory retains all of your ladder logic and data if the controller loses power, eliminating the need for battery back-up or separate memory module. Multiple input commons lets you use the controller for either sinking or sourcing input devices and multiple output commons provide isolation in multi-voltage output applications. RS-232 communication channel allows for simple connectivity to a personal computer for program upload, download, and monitoring by using multiple protocols, including DF1 full-duplex. RTU slave protocol supports using DF1 half-duplex allows up to 254 slave nodes to communicate with a single master by using radio modems, leased-line modems, or satellite uplinks. Peer-to-peer messaging capability that lets you network up to 32 controllers on a DH-485 network by (using a 1761-NET-AIC module). Advanced communication networks, including DeviceNet and EtherNet/IP, through the 1761-NET-DNI and 1761-NET-ENI communication modules. Controllers that have 24V DC inputs include a built-in, high-speed counter (6.6 kHz). Adjustable DC input filters let you customize the input response time and noise rejection to meet your application needs. Regulatory agency certifications for world-wide market (CE, C-Tick, UL, and c-UL, including Class I Division 2 Hazardous Location). Publication 1761-SG001F-EN-P - March 2011 MicroLogix Programmable Controllers Overview 5 MicroLogix 1100 Controller The MicroLogix 1100 controller is designed to broaden application coverage through embedded analog inputs, Ethernet communication, and visualization capabilities. MicroLogix 1100 controllers maintain the same critical features you have come to expect from the MicroLogix family, and expand that capability to include true online editing. MicroLogix 1100 controllers complement our low-end controllers for applications that require up to 144 digital I/O. Each MicroLogix 1100 controller contains 2 embedded analog inputs, with 10 digital inputs and 6 digital outputs. The controller can also expand its I/O capabilities by using the same modules as the MicroLogix 1200 controller. Up to four of the 1762 I/O modules can be used with a single MicroLogix 1100 controller. Using the latest version of our world-class RSLogix 500 programming software, the MicroLogix 1100 controller can be programmed with an instruction set that is common with the MicroLogix and SLC 500 families of controllers. RSLogix 500 Starter, Standard, and Professional applications all support the MicroLogix 1100 controller, including its online editing capabilities. In addition, the new RSLogix Micro Starter and Developer software provide MicroLogix only programming at a lower cost. Each controller supports a built-in RS-232/RS-485 combo port for serial and networked communication and a second built-in EtherNet/IP port, which supports Ethernet peer-to-peer messaging. An embedded LCD screen lets you monitor controller and I/O status, as well as make changes to bit and integer data. Advantages for the MicroLogix 1100 Controllers Large 8 KB memory (4 KB user program with 4 KB user data) to solve a variety of applications. True online editing allows tuning of progr am, including PID, without going offline. Support for MicroLogix 1100 controller online editing in all current versions of RSLogix 500 and RSLogix Micro Starter and Developer software. Mode switch for Run/Remote/Program. Time-based or event-triggered data logging capability stores controller data records with optional time stamp in a separate 128 Kbyte memory area for later analysis (for example, trending and I/O status during alarm condition data). Recipe storage (up to 64 KB that is deducted from Data Logging memory) that is accessible by your ladder program, enabling quick and easy batch changes of program data for timers, counters, and other data types. High performance expansion I/O options (up to four 1762 I/O modules, in any combination). Four high-speed inputs (except 1763-L16AWA controller) that can be used individually as latching (pulse-catch) inputs, event interrupts, or alternately combined as one 40 kHz high-speed counter featuring 8 modes of operation. Two built-in 0...10V DC analog inputs with 10-bit resolution (not isolated). Publication 1761-SG001F-EN-P - March 2011 6 MicroLogix Programmable Controllers Overview Two high-speed outputs that can be configured as 40 kHz pulse train output (PTO) or as pulse width modulated (PWM) outputs (catalog number 1763-L16BBB only). Multiple input commons let you use the controller for either sinking or sourcing input devices, and multiple output commons provide individual isolation in multi-voltage output applications. One, 1 ms, selectable timed interrupt (STI). High-resolution, 1 ms timers. Communication Channel 0 provides isolated RS-232 or RS-485 electrical compatibility (selectable through the choice of communication cables). Through RS-232, we support all serial protocols. Through RS-485, we support direct interface to DH-485, DF1 half-duplex master/slave, ASCII, and Modbus RTU master/slave networks (without an external electrical interface converter). Communication Channel 1 consists of an embedded RJ45 port that supports EtherNet/IP network for peer-to-peer messaging. This 10/100 Mbps port supports BOOTP and DHCP. Communication toggle selection that allows the controller's Channel 0 port to toggle between user-configured communication parameters and factory default settings for an easy way to switch from Modbus RTU or ASCII protocols (which do not support programming) to DF1 full-duplex (to upload/download, monitor, or edit your program). So a programming computer is able to connect to a controller with an unknown or incorrect communication-parameter settings for troubleshooting. Embedded real-time clock. Embedded web server with email functionality. Optional memory module for external program backup, for program transport, and transfer to another controller. Program and data in the controller is also battery backed for secure storage. Data file download protection prevents crit ical user data from being altered via program downloads from programming computers or memory modules. Built-in LCD provides access to 48 bits and 48 integers that can be changed, or optionally protected, for monitor only access by an operator. LCD instruction allows the controller to output messages to the LCD, and optionally receive user input. IP address can be monitored directly through the built-in LCD. Two built-in digital trim potentiometers. 32-bit signed integer math. Floating-point and double-integer data file support. Built-in PID capabilities. Finger-safe terminal blocks meet global safety standards. Regulatory agency certifications for world-wide market (CE, C-Tick, UL, and c-UL, including Class 1 Division 2 Hazardous Location). Publication 1761-SG001F-EN-P - March 2011 MicroLogix Programmable Controllers Overview 7 MicroLogix 1200 Controller The MicroLogix 1200 controller provides more computing power and flexibility than the MicroLogix 1000 controller to solve a variety of application needs. Available in 24- and 40-point versions, the I/O count can be expanded by using rackless I/O modules. This results in larger control systems, greater application flexibility and expandability at a lower cost and reduced parts inventory. A field-upgradable flash operating system that helps to make sure you will always be up-to-date with the latest features, without having to replace hardware. The controller can be easily updated with the latest firmware via a website download. Publication 1761-SG001F-EN-P - March 2011 8 MicroLogix Programmable Controllers Overview Advantages for the MicroLogix 1200 Controller Large 6 KB memory (4 KB User Program with 2 KB User Data) to solve a variety of applications. High performance expansion I/O options (up to six modules depending on current/power budget). Four high-speed inputs (for controllers with 24V DC inputs) that can be used individually as latching (pulse-catch) inputs, event interrupts,or alternately combined as one 20 kHz high-speed counter featuring eight modes of operation. One high-speed output that can be configured as 20 kHz pulse train output (PTO) or as pulse width modulated (PWM) output (availableon controllers with embedded 24V DC outputs). One, 1 ms, selectable timed interrupt (STI). High-resolution, 1 ms timers. The same advanced communication options as the MicroLogix 1000 controller, including peer-to-peer and SCADA/RTU networks, DF1 full-duplex, DF1 half-duplex slave, DH-485, DeviceNet and EtherNet/IP , plus DF1 half-duplex master, Modbus master and slave, and DF1 radio modem protocols. ASCII read/write capability. An additional Programming/HMI Port, provid ing connectivity to a DF1 full-duplex compatible device such as an operator interface or programming terminal (MicroLogix 1200R controllers only, catalog number 1762-LxxxxxR). Communication toggle pushbutton that allows the controller's Channel 0 port to toggle between user configured communication parameters and factory default settings for an easy means to switch from Modbus RTU or ASCII protocols (which do not support programming) to DF1 full-duplex (to upload/download, monitor, or edit your program), so a programming computer is able to connect to a controller with an unknown or incorrect communication parameter settings for troubleshooting. Optional real-time clock, to allow control to be based on actual time of day, day of week, or other calendar related timing. Optional memory module, for external program backup, transport and transfer to another controller. Control program and data are securely backed up to internal flash memory when power is not applied. Data file download protection prevents crit ical user data from being altered via program downloads from programming computers or memory modules. Two built-in analog trim potentiometers. 32-bit signed integer math. Floating-point and double integer data file support. Built-in PID capabilities. Finger-safe terminal blocks meet global safety standards. Removable terminal blocks on 40-point controllers allow pre-wiring. Regulatory agency certifications for world-wide market (CE, C-Tick, UL, c-UL, including Class 1 Division 2 Hazardous Location). Publication 1761-SG001F-EN-P - March 2011 MicroLogix Programmable Controllers Overview 9 MicroLogix 1400 Controller The MicroLogix 1400 controller is our newest family of controllers to join the popular MicroLogix 1000, MicroLogix 1100, MicroLogix 1200, and MicroLogix 1500 controllers, and is designed to broaden application coverage through available embedded analog inputs, Ethernet communication, faster high-speed counter (HSC), and pulse train output (PTO) capabilities. MicroLogix 1400 controllers maintain the same critical features you have come to expect from the MicroLogix 1100 controller, and expands that capability with more I/O, faster HSC/PTO, and an additional serial port. MicroLogix 1400 controllers complement our low-end controllers for applications that require up to 256 digital I/O. Each MicroLogix 1400 controller includes 20 digital inputs and 12 digital outputs. In addition, several models include 4 embedded analog inputs and 2 embedded analog outputs. The controller can also expand its I/O capabilities by using the same modules as the MicroLogix 1100 and 1200 controllers. Up to 7 of the 1762 I/O modules can be used with a single MicroLogix 1400 controller. Using the latest version of our world-class RSLogix 500 programming software, the MicroLogix 1400 controller can be programmed with an instruction set that is common with the MicroLogix 1000, MicroLogix 1100, MicroLogix 1200, MicroLogix 1500, and SLC 500 families of controllers. RSLogix 500 Starter, Standard, and Professional applications, as well as RSLogix Micro software, all support the MicroLogix 1400 controller, including its online editing capabilities. Each controller has 2 serial ports with DF1/DH485/Modbus RTU/DNP3/ASCII protocol support and a built-in Ethernet port, which supports EtherNet/IP, Modbus TCP/IP and DNP3 over IP. An embedded LCD screen lets you monitor controller and I/O status, as well as make changes to bit and integer data. Publication 1761-SG001F-EN-P - March 2011 10 MicroLogix Programmable Controllers Overview Advantages for the MicroLogix 1400 Controller Large memory (10 KB user program with 10 KB user data) to solve a variety of applications. True online editing allows tuning of progra m, including PID, without going offline. Support for MicroLogix 1400 controller online editing in RSLogix 500 Professional, Standard, and Starter software version 8.1 and later, as well as RSLogix Micro. Mode switch for Run/Remote/Program through LCD keypad operation. Time-based or event-triggered data logging capability stores controller data records with optional time stamp in a separate 128 Kbyte memory area for later analysis (for example, trending and I/O status during alarm condition data). Recipe storage (up to 64 KB that is deducted from Data Logging memory) that is accessible by your ladder program, enabling quick and easy batch changes of program data for timers, counters, and other data types. High performance expansion I/O options (up to seven 1762 I/O modules, in any combination). Twelve high-speed inputs (except 1766-L32AWA and 1766-L32AWAA controllers) that can be used individually as latching (pulse-catch) inputs, event interrupts, or alternately combined as three 100 kHz high-speed counters featuring 10 modes of operation. Two available built-in 0...10V DC analog outputs (for controllers with analog I/O options) with 12-bit resolution (not isolated). Three high-speed outputs that can be confi gured as 100 kHz pulse train output (PTO) or 40 kHz as pulse width modulated (PWM) outputs (only on 1766-L32BXB and 1766-L32BXBA controllers). Multiple input commons let you use the controller for either sinking or sourcing input devices, and multiple output commons provide individual isolation in multi-voltage output applications. One, 1 ms, selectable timed interrupt (STI). High-resolution, 1 ms timers. Communication Channel 0 provides isolated RS-232 or RS-485 electrical compatibility (selectable through the choice of communication cables). Through RS-232, we support all serial protocols. Through RS-485, we support direct interface to DH-485, DF1 half-duplex master/slave, ASCII, and Modbus RTU master/slave networks, DNP 3 slave using the 1763-NC interface (1761-NET-AIC interface is not required). Communication Channel 1 consists of an embedded RJ45 port that supports EtherNet/IP, Modbus TCP/IP and DNP3 over IP. This 10/100 Mbps port supports BOOTP and DHCP. Communication channel 2 provides a 9-pin, non-isolated RS-232 port supporting all serial protocols. Communication toggle selection that allows the controller's Channel 0 port to toggle between user-configured communication parameters and factory default settings for an easy way to switch from Modbus RTU or ASCII protocols (which do not support programming) to DF1 full-duplex (to upload/download, monitor, or edit your program). So a programming computer is able to connect to a controller with an unknown or incorrect communication-parameter settings for troubleshooting. Embedded real-time clock. Embedded web server with email functionality. Publication 1761-SG001F-EN-P - March 2011 MicroLogix Programmable Controllers Overview 11 Optional memory module for external program backup, for program transport, and transfer to another controller. Program and data in the controller is also battery backed for secure storage. Data file download protection prevents crit ical user data from being altered via program downloads from programming computers or memory modules. Built-in LCD provides access to binary and integer files that can be changed, or optionally protected, for monitor only access by an operator. LCD instruction allows the controller to output messages to the LCD, and optionally receive user input. IP address can be monitored and configured directly through the built-in LCD. Two built-in digital trim potentiometers. 32-bit signed integer math. Floating-point and double-integer data file support. Built-in PID capabilities. Finger-safe removable terminal blocks meet global safety standards. Customizable OEM logos on the LCD display. Regulatory agency certifications for world-wide market (CE, C-Tick, cUL, and UL (1) including Class 1 Division 2 Hazardous Location, where product is marked ). (1) See the Product Certification link at http://www.ab.com for Declaration of Conformity, Certificates, and other certification details. Publication 1761-SG001F-EN-P - March 2011 12 MicroLogix Programmable Controllers Overview MicroLogix 1500 Controller The MicroLogix 1500 controller is a world-class programmable logic control platform with even more advanced features and performance than the MicroLogix 1200 controller. Many of these features allow this controller to be used in applications where much larger controllers were required in the past. MicroLogix 1500 architecture features an innovative two-piece design with a small footprint. The processor and base units slide together to form the complete controller. The processor and base are independently replaceable, allowing you to maximize your embedded I/O, memory, and communication options while minimizing inventory stocking costs. Bulletin 1769 Compact I/O modules expand the controller’s embedded I/O offerings and provide the additional flexibility to cover a wide range of applications. This high-performance modular and rackless I/O platform provides front accessibility for removal and insertion. Removable terminal blocks further lower the total system cost by reducing start-up and maintenance time. New features are provided with an enhanced user interface that uses function files to consolidate programming parameters. This simplifies the user interface and increases controller performance. The MicroLogix 1500 controller includes all the features of the MicroLogix 1200 controller, plus more. Publication 1761-SG001F-EN-P - March 2011 MicroLogix Programmable Controllers Overview 13 Advantages for the MicroLogix 1500 Controller (in addition to MicroLogix 1200 controller features) Large memory to solve a variety of applications. 1764-LSP: 7 KB user program capacity (3.65 KB User Program with 4 KB User Data) 1764-LRP:14 KB user program capacity (10 KB User Program with 4 KB User Data) Mode switch for Run/Remote/Program. MicroLogix 1500 controllers using the 1764-LRP processor, can perform time based or event triggered data logging. This allows the controller to store data records with optional time stamp in a separate 48 Kbyte memory area for later analysis (for example, trending and I/O status during alarm condition data). Recipe storage (up to 48 KB that is deducted from Data Logging memory), that is accessible by your ladder program, enabling quick and easy batch changes of program data for timers, counters, and other data types.). High performance expansion I/O options (up to 16 modules by using an additional bank of expansion I/O and expansion power supply). There is an additional Channel 1 configurable isolated RS-232 communication port on the 1764-LRP processor (for peer-to-peer and SCADA/RTU networks, DH-485, DeviceNet and EtherNet/IP). Battery for nonvolatile user program and user data (built-in and optional replacement). Optional data access tool (1764-DAT) allows a user to change integer and bit values within the controller, or optionally protect these elements for monitor only. Eight high-speed inputs (for controllers with 24V DC inputs) that can be used individually as latching (pulse-catch) inputs, event interrupts, or alternately combined in groups of four (0...3, and 4...7) as two 20 kHz high-speed counters featuring eight modes of operation. Two high-speed outputs that can be configur ed as 20 kHz pulse train output (PTO) or as pulse width modulated (PWM) outputs (available on controllers with embedded 24V DC outputs). Removable terminal blocks on all MicroLogix 1500 base units and I/O modules enable pre-wiring. Publication 1761-SG001F-EN-P - March 2011 14 MicroLogix Controller System-selection Checklist Use the following checklist as a guide to completing your own system specification. Skip any MicroLogix Controller sections that do not apply. System-selection Checklist ✔ Step See Select Family: MicroLogix 1000, 1200 or 1500 Controller page 17 1 • controller family - based on memory, I/O, added functionality, programming instructions and dimensions • consider future expansion requirements • consider requirement for online editing • consider the need for networked communication Select Family: MicroLogix 1100 or 1400 Controller page 21 • controller family - based on memory, I/O, added functionality, programming instructions and dimensions • consider future expansion requirements • consider requirement for online editing • consider the need for networked communication Select Communication page 33 2 • communication network - based on application requirementscommunication network - based on application requirements • communication interface device - if required Select Programming Tools and Software page 38 3 • programming tools - hand-held programmer with optional memory module (available for MicroLogix 1000 only) • software - the appropriate RSLogix package for your application Select Network and Programming Cables page 39 4 cables - review device port identification to find cable in the selection chart) Select MicroLogix 1000 Controllers page 41 5 controller - review power and I/O configurations to select a controller catalog number; see power supply and I/O specification for more detailed information Select MicroLogix 1100 Controllers page 46 6 • controller - review power and I/O configurations to select a controller catalog number; see power supply and I/O specification for more detailed information • accessories - memory modules Select MicroLogix 1100 Expansion I/O page 50 7 I/O modules - digital, analog, and temperature Select MicroLogix 1200 Controllers page 58 8 • controller - review power and I/O configurations to select a controller catalog number; see power supply and I/O specifications for more detailed information • accessories - memory and real-time clock modules Select MicroLogix 1200 Expansion I/O page 61 9 • I/O modules - digital, analog, and temperature • perform system expansion calculations Select MicroLogix 1400 Controllers page 64 10 • I/O modules - digital, analog, and temperature • perform system expansion calculations Select MicroLogix 1400 Expansion I/O page 69 11 I/O modules - digital, analog, and temperature Select MicroLogix 1500 Controllers page 70 12 • base unit - review power and I/O configurations to select a catalog number; see power supply and I/O specifications for more detailed information • processor - see notes at Step 1 • accessories - data access tool; real-time clock and memory modules Select MicroLogix 1500 System Expansion Components page 74 13 • I/O modules - digital, analog, temperature and high-speed counter • communication modules - DPI SCANport and DeviceNet • power supplies, cables and end caps • perform system expansion calculations Publication 1761-SG001F-EN-P - March 2011 MicroLogix Controller System-selection Checklist 15 ✔ Step See Select Replacement Parts page 84 14 Select Training Materials page 85 15 training and promotional products - starter paks, demo units and simulators Fill in Your Selection Listing page 86 16 all catalog numbers required for your system specification Publication 1761-SG001F-EN-P - March 2011 16 Select a MicroLogix Controller Use this document to complete the following selection steps. Select a MicroLogix Controller 1. Select Family: MicroLogix 1000, 1100, 1200, 1400, or 1500 Controller. 2. Select Communication. 3. Select Programming Tools and Software. 4. Select Network and Programming Cables. 5. Select MicroLogix 1000 Controllers. 6. Select MicroLogix 1100 Controllers. 7. Select MicroLogix 1100 Expansion I/O. 8. Select MicroLogix 1200 Controllers. 9. Select MicroLogix 1200 Expansion I/O. 10. Perform MicroLogix 1200 Controller System Expansion Calculations. 11. Select MicroLogix 1400 Controllers. 12. Select MicroLogix 1400 Expansion I/O. 13. Select MicroLogix 1500 Controllers. 14. Select MicroLogix 1500 System Expansion Components. 15. Perform MicroLogix 1500 System Expansion Calculations. 16. Select Replacement Parts. 17. Select Training Materials. 18. Fill in Your Selection Listing. Publication 1761-SG001F-EN-P - March 2011 Select Family: MicroLogix 1000, 1200 or 1500 Controller 17 Review the Features, Programming Instructions, Controller Specifications, and Controller Select Family: MicroLogix Dimensions to determine which level of MicroLogix controller is required. 1000, 1200 or 1500 Controller Features MicroLogix Controllers Feature Comparison Chart Step 1 - Select: Controller MicroLogix 1000 MicroLogix MicroLogix 1500 1200/1200R 1764-LSP, 1764-LRP • controller family - based on memory, I/O, added functionality, programming Bulletin Number 1761 1762 1764 instructions and dimensions Memory (in user words) User Program/User Data • consider future expansion requirements • consider requirement for online editing Up to 1 KB 1 KB combined • consider the need for networked (preconfigured) communication Up to 6 KB 4 KB/2 KB Up to 7 KB 3.6 KB/4 KB 1764-LSP Up to 8 KB Up to 14 KB 10 KB/4 KB 1764-LRP Online editing Nonvolatile program and data EEPROM Flash Battery back-up static RAM Memory Module (for program Through hand-held Optional Optional back-up and transport) programmer I/O Embedded Digital I/O, max 32 40 28 Embedded Analog I/O Two current and two voltage inputs with one current or voltage output on 20 pt. controllers Local Expansion I/O, max None 96 512 Thermocouple/RTD None Expansion Expansion Networked Expansion I/O, max None None DeviceNet network using 1769-SDN scanner can own 63 slave devices (such as a 1769-ADN adapter with up to 30 I/O modules per 1769-ADN adapter) Added Functionality Trim Potentiometers 2 2 PID ✓✓ High Speed Counters One @ 6.6 kHz One @ 20 kHz Two @ 20 kHz (embedded) High Speed Counters with 1769-HSC counter (expansion) With two quadrature or four pulse/count @ 1 MHz Real Time Clock Optional Optional Motion: Pulse Width Modulated 1 @ 20 kHz 2 @ 20 kHz Motion: Pulse Train Outputs 1 @ 20 kHz 2 @ 20 kHz Data Access Tool Optional Data Logging 48 KB Recipe Storage Uses user program memory or 48 KB data logging memory Floating Point Math ✓✓ Programming Windows - RSLogix 500/Micro ✓✓✓ Software Hand-held Programmer ✓ Communication Publication 1761-SG001F-EN-P - March 2011 18 Select Family: MicroLogix 1000, 1200 or 1500 Controller MicroLogix Controllers Feature Comparison Chart Controller MicroLogix 1000 MicroLogix MicroLogix 1500 1200/1200R 1764-LSP, 1764-LRP Bulletin Number 1761 1762 1764 RS-232 Ports (1) 8-pin mini DIN (1) 8-pin mini DIN (1) 8-pin mini DIN (1) 8-pin mini DIN (1) 9-pin D-shell Programming/HMI DeviceNet Peer-to-Peer With 1761-NET-DNI With 1761-NET-DNI With 1761-NET-DNI Messaging, slave I/O With 1769-SDN DeviceNet Scanner With 1769-SDN EtherNet/IP With 1761-NET-ENI or With 1761-NET-ENI or With 1761-NET-ENI or 1761-NET-ENIW 1761-NET-ENIW 1761-NET-ENIW Web Server Capabilities With 1761-NET-ENIW With 1761-NET-ENIW With 1761-NET-ENIW DH-485 Network with Network with Network with 1761-NET-AIC 1761-NET-AIC 1761-NET-AIC SCADA RTU - DF1 half-duplex ✓✓✓ slave SCADA RTU - DF1 radio modem ✓✓ SCADA RTU - Modbus RTU slave ✓✓ SCADA RTU - Modbus RTU ✓✓ master ASCII - Read/Write ✓✓ Operating Power 120/240V AC ✓✓✓ 24V DC ✓✓✓ 12V DC Agency Certifications CE, C-Tick, UL, and C-UL ✓✓✓ (including Class I, Division 2 Hazardous Location) Programming Instructions MicroLogix controllers have the range of functionality necessary to address diverse applications. The controllers use the following types of instructions: Basic instructions (for example, Examine if On, Examine if Off) Data Comparison instructions (for exampl e, Equal, Greater than or Equal, Less than or Equal) Data Manipulation instructions (for example, Copy, Move) Math instructions (for example, Add, Subtract, Multiply) Program Flow Control instructions (for example, Jump, Subroutine) Application Specific instructions (for example, Programmable Limit Switch, Sequencer) High-speed Counter instruction High-speed pulse train output (PTO) and pulse width modulated (PWM) instructions (for MicroLogix 1200 and 1500 controllers only) Communication instruction (including ASCII for MicroLogix 1200 and 1500 controllers only) Recipe instruction (MicroLogix 1500 controllers only) Data Logging instruction (MicroLogix 1500 1764-LRP processor only) Publication 1761-SG001F-EN-P - March 2011 Select Family: MicroLogix 1000, 1200 or 1500 Controller 19 Controller Specifications Controller General Specifications Attribute MicroLogix 1000 MicroLogix 1200 MicroLogix 1500 (Bulletin 1761) (Bulletin 1762) (Bulletin 1764) Memory Size and Type 1 KB EEPROM (approximately 6 KB flash memory: 4 KB user 1764-LSP processor: 7 KB user 737 instruction words, 437 program, 2 KB user data memory (total user program data words) plus data) 1764-LRP processor: 14 KB user memory (total user program plus data) Data Elements 512 internal bits, 40 timers, 32 configurable, user-defined file configurable, user-defined file counters, 16 control files, 105 structure, 2 KB max data size structure, 4 KB max data size integer files, 33 diagnostic status Throughput 1.5 ms (for a typical 2 ms (for a typical 1 KB word 1 ms (for a typical 1 KB word (1) (2) (2) 500-instruction program) user program) user program) (1) A typical program contains 360 contacts, 125 coils, 7 timers, 3 counters, and 5 comparison instructions. (2) A typical user program contains bit, timer, counter, math, and file instructions. Environmental Specifications and Certifications Attribute 1761 Controllers 1762 Controllers 1764 Controllers Operating Temperature Horizontal mounting: 0…55 °C (32…131 °F) 0…55 °C (32…131 °F) 0…55 °C (32…131 °F) (1) Vertical mounting : 0 °C…45 °C (32 °F…113 °F) for digital I/O, 0 °C…40 °C (32 °F…104 °F) for analog I/O (2) Storage Temperature -40…85 °C (-40…185 °F) -40…85 °C (-40…185 °F) -40…85 °C (-40…185 °F) Relative Humidity 5…95%, noncondensing 5…95%, noncondensing 5…95%, noncondensing Vibration Operating: 5 Hz…2 kHz, 0.381 10…500 Hz, 5 g, 0.030 in. max 10…500 Hz, 5 g, 0.030 in. max mm (0.015 in.) peak-to-peak, peak-to-peak, 2 hours each peak-to-peak (Relay (3) axis Operation: 2 g) 2.5 g panel mounted , 1 hr (Relay Operation: 1.5 g) per axis Nonoperating: 5 Hz…2 kHz, 0.762 mm (0.030 in.) peak-to-peak, 5 g, 1 hr per axis Shock, Operating 10 and 16 Point Controllers: 30 g; 3 pulses each direction, without Data Access Tool each axis installed: 10 g peak acceleration (7.5 g (Relay Operation: 7 g) DIN rail mounted) (11 ± 1 ms 30 g panel mounted (15 g DIN duration) 3 times each Rail mounted) direction, each axis Relay operation: 7.5 g panel mounted (5 g DIN Rail 32 Point and Analog mounted) Controllers: with Data Access Tool 7.5 g peak acceleration (5.0 g installed: DIN rail mounted) (11 ± 1 ms 20 g panel mounted (15 g DIN duration) 3 times each Rail mounted) direction, each axis Relay operation: 7.5 g panel mounted (5 g DIN Rail mounted) Publication 1761-SG001F-EN-P - March 2011 20 Select Family: MicroLogix 1000, 1200 or 1500 Controller Environmental Specifications and Certifications Attribute 1761 Controllers 1762 Controllers 1764 Controllers Shock, Nonoperating 10 and 16 Point Controllers: 50 g panel mounted (40 g DIN without Data Access Tool Rail mounted); 3 pulses each installed: 20g peak acceleration (11 ± 1 direction, each axis ms duration), 3 times each 40 g panel mounted (30 g DIN direction, each axis Rail mounted) with Data Access Tool 32 Point and Analog installed: Controllers: 30 g panel mounted (20 g DIN 20g peak acceleration (11 ± 1 Rail mounted) ms duration), 3 times each direction, each axis Agency Certification • UL Listed Industrial Control Equipment for use in Class 1, Division 2, Hazardous Locations, Groups A, B, C, D • C-UL Listed Industrial Control Equipment for use in Canada • CE marked for all applicable directives • C-Tick marked for all applicable acts Electrical/EMC The controller has passed testing at the following level ESD Immunity EN 61000-4-2 EN 61000-4-2 8 kV 4 kV contact, 8 kV air, 4 kV indirect Radiated Immunity Radiated RF Immunity EN 61000-4-3 EN 61000-4-3 10 V/m, 27…1000 MHz, 10 V/m, 80…1000 MHz, 80% amplitude modulation, +900 MHz 3 V/m, 87…108 MHz, keyed carrier 174…230 MHz, and 470…790 MHz Electronic Fast EN 61000-4-4 EN 61000-4-4 Transient/Burst (EFT/B) Power Supply, I/O: 2 kV Power Supply, I/O: 2 kV, 5 kHz Immunity Communication: 1 kV Communication Cable: 1 kV, 5 kHz Surge Transient EN 61000-4-5 EN 61000-4-5 Immunity Communication: 1 kV galvanic Communication: 1 kV galvanic gun gun I/O: 2 kV CM (common mode), 1 kV DM (differential mode) I/O: 2 kV CM (Common mode), AC Power Supply: 4 kV CM (Common mode), 2 kV DM 1 kV DM (Differential mode) (Differential mode) AC Power Supply: 4 kV CM DC Power Supply: 500V CM (Common mode), 500V DM (Common mode), 1 kV DM (Differential mode) (Differential mode) Conducted RF Immunity EN 61000-4-6 EN 61000-4-6 Power Supply, I/O: 10V, 150 Power Supply, I/O: 10V kHz…30 MHz Communication Cable 3V Communication Cable 3V (1) DC input voltage derated linearly from 30 °C (86 °F) (30…26.4V). (2) Recommended storage temperature for maximum battery life (5 years typical with normal operating/storage conditions) of Real-time Clock modules is -40…40 °C (-40…104 °F). Battery life can be significantly shorter at elevated temperatures. Applies to 1762-RTC, 1762-MM1RTC, 1764-RTC, 1764-MM1RTC, and 1764-MM2RTC devices. (3) DIN rail mounted controller is 1 g. Publication 1761-SG001F-EN-P - March 2011 Select Family: MicroLogix 1100 or 1400 Controller 21 Review the Features, Programming Instructions, Controller Specifications, and Controller Select Family: MicroLogix Dimensions to determine which level of MicroLogix controller is required. 1100 or 1400 Controller Features MicroLogix Controllers Feature Comparison Chart Step 1 - Select: Controller MicroLogix 1100 MicroLogix 1400 • controller family - based on memory, I/O, Bulletin Number 1763 1766 added functionality, programming Memory (in user words) User Program/User Data instructions and dimensions • consider future expansion requirements Up to 1 KB • consider requirement for online editing • consider the need for networked Up to 6 KB communication Up to 7 KB Up to 8 KB 4 KB/4 KB Up to 14 KB Up to 20 KB 10 KB/10 KB Online editing ✓✓ Nonvolatile program and data Battery back-up static RAM Battery back-up static RAM Memory Module (for program Optional Optional back-up and transport) I/O Embedded Digital I/O, max 16 32 Embedded Analog I/O Two 0…10V DC inputs on all controllers Four 0…10V DC inputs on some controllers Two 0...10V DC outputs on some controllers Local Expansion I/O, max 144 256 Thermocouple/RTD Expansion Expansion Added Functionality Trim Potentiometers Two (digital) Two (digital) PID ✓✓ High Speed Counters One @ 40 kHz Up to six @ 100 kHz (embedded) Real Time Clock ✓✓ Motion: Pulse Width Modulated 2 @ 40 kHz 3 @ 40 kHz Motion: Pulse Train Outputs 2 @ 40 kHz 3 @ 100 kHz Data Access Tool ✓✓ Data Logging 128 KB 128 KB Recipe Storage Uses up to 64 KB data logging memory Uses up to 64 KB data logging memory Floating Point Math ✓✓ Programming Windows - RSLogix 500 ✓✓ Software RSLogix Micro ✓✓ Communication RS-232 Ports (1) 8-pin mini DIN (1) 8-pin mini DIN (1) 9-pin D-shell DeviceNet Peer-to-Peer With 1761-NET-DNI With 1761-NET-DNI Messaging, slave I/O EtherNet/IP ✓✓ Web Server Capabilities ✓✓ DH-485 Network with 1763-NC01 Network with 1763-NC01 Publication 1761-SG001F-EN-P - March 2011 22 Select Family: MicroLogix 1100 or 1400 Controller MicroLogix Controllers Feature Comparison Chart Controller MicroLogix 1100 MicroLogix 1400 Bulletin Number 1763 1766 SCADA RTU - DF1 half-duplex ✓✓ master/slave SCADA RTU - DF1 radio modem ✓✓ SCADA RTU - Modbus RTU slave ✓✓ SCADA RTU - Modbus RTU ✓✓ master SCADA RTU - DNP3 slave ✓ ✓ ASCII - Read/Write ✓ DNP3 over IP ✓ Modbus TCP/IP ✓ Operating Power 120/240V AC ✓✓ 24V DC ✓✓ 12V DC ✓ Agency Certifications CE, C-Tick, UL, and C-UL ✓✓ (including Class I, Division 2 (1) Hazardous Location) (1) See the Product Certification link at http://www.ab.com for Declarations of Conformity, Certificates, and other certification details. Programming Instructions MicroLogix controllers have the range of functionality necessary to address diverse applications. The controllers use the following types of instructions: Basic instructions (for example, Examine if On, Examine if Off) Data Comparison instructions (for exampl e, Equal, Greater than or Equal, Less than or Equal) Data Manipulation instructions (for example, Copy, Move) Math instructions (for example, Add, Subtract, Multiply) Program Flow Control instructions (for example, Jump, Subroutine) Application Specific instructions (for example, Programmable Limit Switch, Sequencer) High-speed Counter instruction High-speed pulse train output (PTO) and pulse width modulated (PWM) instructions Communication instruction including ASCII Recipe instruction Data Logging instruction LCD instruction Trigonometry instructions (MicroLogix 1400 controllers only) y Advanced math instructions (for example, x , compute - MicroLogix 1400 controllers only) Advanced timing instructions (for example, Read High-speed clock, compute time difference - MicroLogix 1400 controllers only) Publication 1761-SG001F-EN-P - March 2011 Select Family: MicroLogix 1100 or 1400 Controller 23 Controller Specifications Controller General Specifications Attribute MicroLogix 1100 MicroLogix 1400 (Bulletin 1763) (Bulletin 1766) Memory Size and Type 8 KB battery backed RAM: 20 KB battery backed RAM: 4 K user program, 10 K user program, 4 K user data 10 K user data Data Elements configurable, user defined file configurable, user defined file structure, 4 KB max data size structure, 10 KB max data size Throughput 1.5 ms (for a typical 1 KB word 0.7 ms (for a typical 1 KB word (1) (1) user program) user program) (1) A typical user program contains bit, timer, counter, math, and file instructions. Environmental Specifications and Certifications Attribute 1763 Controllers 1766 Controllers Operating Temperature -20…65 °C (-4…149 °F) -20…60 °C (-4…140 °F) Storage Temperature -40…85 °C (-40…185 °F) -40…85 °C (-40…185 °F) Relative Humidity 5…95%, noncondensing 5…95%, noncondensing Vibration 10…500 Hz, 5 g, 0.015 in. max 10…500 Hz, 3 g, 0.015 in. max peak-to-peak, (Relay peak-to-peak Operation: 1.5 g) Shock, Operating 30 g; 3 pulses each direction, 30 g; 3 pulses each direction, each axis each axis (Relay Operation: 7 g) Shock, Nonoperating 50 g panel mounted (40 g Din 50 g panel mounted (40 g Din Rail mounted); 3 pulses each Rail mounted); 3 pulses each direction, each axis direction, each axis Agency Certification • UL Listed Industrial • UL Listed Industrial Control Equipment for Control Equipment for use in Class 1, use in Class 1, Division 2, Hazardous Division 2, Hazardous Locations, Groups A, Locations, Groups A, B, C, D B, C, D • C-UL Listed Industrial • C-UL Listed Industrial Control Equipment for Control Equipment for use in Canada use in Canada • CE marked for all • CE marked for all applicable directives applicable directives • C-Tick marked for all • C-Tick marked for all applicable acts applicable acts Electrical/EMC ESD Immunity EN 61000-4-2 EN 61000-4-2 4 kV contact, 8 kV air, 4 kV 4 kV contact, 8 kV air indirect Radiated Immunity ENV 50204 10 V/m, 1000 MHz Radiated RF Immunity EN 61000-4-3 EN 61000-4-3 10V/m, 26...1000 MHz 10V/m, 26...1000 MHz (alternatively, 80...1000 MHz), (alternatively, 80...1000 MHz), 80% amplitude modulation, 80% amplitude modulation, +900 MHz keyed carrier +900 MHz keyed carrier Publication 1761-SG001F-EN-P - March 2011 24 Select Family: MicroLogix 1100 or 1400 Controller Environmental Specifications and Certifications Attribute 1763 Controllers 1766 Controllers Electronic Fast EN 61000-4-4 EN 61000-4-4 Transient/Burst (EFT/B) 2 kV, 5 kHz 2 kV, 5 kHz Immunity communication cable such as communication cable such as EtherNet, RS-232, and RS-485: EtherNet, RS-232, and RS-485: 1 kV, 5 kHz 1 kV, 5 kHz Surge Transient EN 61000-4-5 EN 61000-4-5 Immunity Unshielded communication ±1 kV line-line (DM) and ±2 kV cable: 2 kV CM (common line-earth (CM) on AC power mode), 1 kV DM (differential ports mode) ±1 kV line-line (DM) and ±2 kV Shielded communication line-earth (CM) on signal ports cable: 1 kV galvanic gun ±1 kV line-earth (CM) on I/O: 2 kV CM (common mode), communication ports 1 kV DM (differential mode) AC Power Supply Input: 4 kV CM (common mode), 2 kV DM (differential mode) DC Power Supply Input: 500V CM (common mode), 500V DM (differential mode) AC/DC Auxiliary Output: 500V CM (common mode), 500V DM (differential mode) Conducted RF Immunity EN 61000-4-6 EN 61000-4-6 10V, 150 kHz...80 MHz 10V, 150 kHz...80 MHz Conducted Emissions EN 55011 EN 55011 AC Power Supply Input: 150 AC Power Supply Input: 150 kHz...30 MHz kHz...30 MHz Radiated Emissions EN 55011 EN 55011 30...1000 MHz 30...1000 MHz Line Related Tests EN 61000-4-11 EN 61000-4-11 AC Power Supply Input: 60% dip for 10 periods on AC voltage drop: -30% for 10 ms, supply ports -60% for 100 ms 30% dips for 25 periods at 0× voltage interrupt: at voltage and 180× on AC supply ports greater than -95% for 5 s. 100% dip for 250 periods at 0× voltage fluctuation: +10% for and 180× on AC supply ports 15 minutes, -10% for 15 100% dip for 0.5 periods, minutes arbitrary angle, on AC supply DC Power Supply Input: ports voltage fluctuation: +20% for 15 minutes, -20% for 15 minutes Publication 1761-SG001F-EN-P - March 2011 Select Family: MicroLogix 1100 or 1400 Controller 25 Controller Dimensions MicroLogix 1000 Controller Dimensions are in millimeters (inches). Controller Spacing = 50 mm (2 in.) on all sides for adequate ventilation. MicroLogix Controller Dimensions 1761-L10BWA, 1761-L10BWB, 1761-L10BXB, 1761-L16AWA 1761-L20AWA,1761 -L20BWA, 1761-L20BWB, 1761-L16BBB, 1761-L16BWA, 1761-L16BWB, 1761-L32AWA,1761 -L32BWA, 1761-L32AAA, 1761-L16NWA, 1761-L16NWB 1761-L32BBB, 1761-L32BWB 80 (3.15) 80 (3.15) 80 (3.15) 120 133 200 (4.72) (5.24) (7.87) MicroLogix 1000 DIN Rail 1761-L10BWB, 1761-L16BWB, 1761-L10BWA, 1761-L16AWA, 1761-L16BWA, Dimensions 1761-L16BBB, 1761-L16NWB, 1761-L16NWA, 1761-L20AWA, 1761-L20BWA, 1761-L20BWB, 1761-L32BWB, 1761-L32AWA, 1761-L32BWA, 1761-L32AAA 1761-L32BBB 33 (1.3) 80 (3.15) 80 (3.15) 84 (3.3) DIN Rail 16 (0.63) 73 40 (2.87) (1.57) Publication 1761-SG001F-EN-P - March 2011 26 Select Family: MicroLogix 1100 or 1400 Controller MicroLogix 1100 Controller Dimensions are in millimeters (inches). Controller Spacing = 50 mm (2 in.) on all sides for adequate ventilation. MicroLogix 1100 Controller Dimension Drawing C A B MicroLogix 1100 Controller Dimensions Dimension 1763-L16AWA, 1763-L16BWA, 1763-L16BBB, 1763-L16DWD A 90 mm (3.5 in.) B 110 mm (4.33 in.) C 87 mm (3.43 in.) 1762 Expansion I/O Module Dimension Drawing A C B 1762 Expansion I/O Dimensions Dimension Expansion I/O Module A 90 mm (3.5 in.) B 40 mm (1.57 in.) C 87 mm (3.43 in.) Publication 1761-SG001F-EN-P - March 2011 Select Family: MicroLogix 1100 or 1400 Controller 27 Controller Spacing The controller mounts horizontally, with the expansion I/O extending to the right of the controller. Allow 50 mm (2 in.) of space on all but the right side for adequate ventilation, as shown below. ESC OK DIN Rail Mounting The maximum extension of the latch is 14 mm (0.55 in.) in the open position. A flat-blade screwdriver is required for removal of the controller. The controller can be mounted to EN50022-35 x 7.5 or EN50022-35 x 15 DIN rails. DIN rail mounting dimensions are shown below. B A C DIN Rail Mounting Dimensions Dimension Height A 90 mm (3.5 in.) B 27.5 mm (1.08 in.) C 27.5 mm (1.08 in.) Publication 1761-SG001F-EN-P - March 2011 28 Select Family: MicroLogix 1100 or 1400 Controller MicroLogix 1200 Controller Dimensions are in millimeters (inches). Controller Spacing = 50 mm (2 in.) on all sides for adequate ventilation. MicroLogix 1200 Controller Dimension Drawing C C A A B B 1762-L24AWA, 1762-L24BWA, 1762-L24BXB 1762-L40AWA, 1762-L40BWA, 1762-L40BXB 1762-L24AWAR, 1762-L24BWAR, 1762-L24BXBR 1762-L24AWAR, 1762-L24BWAR, 1762-L24BXBR Controller Dimensions Dimension 1762-L24AWA 1762-L24BWA 1762-L24BXB 1762-L40AWA 1762-L40BWA 1762-L40BXB 1762-L24AWAR 1762-L24BWAR 1762-L24BXBR 1762-L40AWAR 1762-L40BWAR 1762-L40BXBR A 90 mm (3.5 in.) 90 mm (3.5 in.) B 110 mm (4.33 in.) 160 mm (6.30 in.) C 87 mm (3.43 in.) 87 mm (3.43 in.) 1762 Expansion I/O Dimensions A 1762 I/O Dimensions Dimension Expansion I/O Module A 90 mm (3.5 in.) B 40 mm (1.57 in.) C C 87 mm (3.43 in.) B Publication 1761-SG001F-EN-P - March 2011 Select Family: MicroLogix 1100 or 1400 Controller 29 MicroLogix 1200 System Mounting Dimensions For more than 2 modules: (number of modules - 1) x 40 mm (1.58 in.) 40.4 14.5 (1.59) (0.57) 100 90 MicroLogix (3.94) (3.54) 1200 A = 95.86mm (3.774 in.) A 40.4 1762-L24AWA, 1762-L24BWA, 1762-L24BXB B (1.59) 1762-L24AWAR, 1762-L24BWAR, 1762-L24BXBR Important: All dimensions are in B = 145.8 mm (5.739 in.) mm (inches). Hole spacing 1762-L40AWA, 1762-L40BWA, 1762-L40BXB tolerance: ±0.4 mm (0.016 in.). 1762-L40AWAR, 1762-L40BWAR, 1762-L40BXBR MicroLogix 1400 Controller Dimensions are in millimeters (inches). Controller Spacing = 50 mm (2 in.) on all sides for adequate ventilation. Refer to page 27 for DIN rail mounting dimensions. MicroLogix 1400 Controller Dimension Drawing C A B 1766-L32BWA, 1766-L32AWA, 1766-L32BXB, 1766-L32BWAA, 1766-L32AWAA, 1766-L32BXBA Controller Dimensions Dimension Height A 90 mm (3.5 in.) B 180 mm (7.08 in.) C 87 mm (3.43 in.) Publication 1761-SG001F-EN-P - March 2011 1762 I/O 1762 I/O 1762 I/O 30 Select Family: MicroLogix 1100 or 1400 Controller 1762 Expansion I/O Dimensions A 1762 I/O Dimensions Dimension Expansion I/O Module A 90 mm (3.5 in.) B 40 mm (1.57 in.) C C 87 mm (3.43 in.) B MicroLogix 1400 System Mounting Dimension 180.0 mm 25.81 mm (7.08 in.) (1.016 in.) 165.8 mm (6.52 in.) 0.164 100.0 mm (3.93 in.) 1766-L32AWA, 1766-L32AWAA 1766-L32BWA, 1766-L32BWAA 1766-L32BXB, 1766-L32BXBA Publication 1761-SG001F-EN-P - March 2011 Select Family: MicroLogix 1100 or 1400 Controller 31 MicroLogix 1500 Controller Dimensions are in millimeters (inches). Hole spacing tolerance: ±0.04 mm (0.016 in.). Controller Spacing = 50 mm (2 in.) on all sides for adequate ventilation. Compact I/O System with MicroLogix 1500 Base Unit and Processor 168 mm 35 mm 28.5 mm (6.62 in) (1.38 in) Mounting Hole (1.12 in) Dimension 147 mm 35 mm (5.79 in) (1.38 in) DIN Rail Center Line 13.5 mm 14.7 mm controller depth = 87 mm (3.43 in.) (0.53 in) (0.58 in) Publication 1761-SG001F-EN-P - March 2011 122.6 mm (4.83 in) 59 mm 59 mm (2.32 in) (2.32 in) 118 mm (4.65 in) 147.4 mm (5.81 in) 132 mm (5.19 in) 32 Select Family: MicroLogix 1100 or 1400 Controller Expansion Bank with Power Supply, Expansion Cable, and End Cap 35 mm 70 mm 35 mm 28.5 mm (1.38 in) (2.76 in) (1.38 in) Mounting Hole (1.12 in) Dimension 35 mm 35 mm 35 mm 35 mm (1.38 in) (1.38 in) (1.38 in) (1.38 in) DIN Rail Center Line 14.7 mm controller depth = 87 mm (3.43 in.) (0.58 in) Expansion Cable connector and End Cap have identical dimensions. Spacing for Single-wide and One and One-half-wide Modules Panel Mounting Using the Dimensional Template: Spacing for single-wide modules 35 mm (1.378 in.) Spacing for one-and-a half-wide modules 52.5 mm (2.067 in.) Spacing from controller to first I/O mounting hole 35 mm (1.378 in.) Important: Overall hole spacing tolerance: ±0.4 mm (0.016 in.). Locate holes every 17.5 mm (0.689 in.) to allow for a mix of single-wide (for example 1769-IQ16 module) and one-and-one-half-wide modules (for example 1769-OA16 module). Publication 1761-SG001F-EN-P - March 2011 122.6 mm (4.83 in) 59 mm 59 mm (2.32 in) (2.32 in) 118 mm (4.65 in) Host Controller 147.4 mm (5.81 in) 132 mm (5.19 in) Select Communication 33 Communication Networks Select Communication MicroLogix controllers allow you to choose the network that best meets your needs. Step 2 - Select: Channel 0 Isolated RS-232/RS-485 Combo port (MicroLogix 1100 and 1400 controllers only) • communication network - based on application requirementsEtherNet/IP port (MicroLogix 1100 and 1400 controllers only) • communication interface device - if DNP3 over IP (MicroLogix 1400 controller only) required Modbus TCP/IP (MicroLogix 1400 controller only) • record your selection in the Selection Record (starts on page 86) • For RS-232 communication: • 300, 600, 1200, 4800, 9600 bps; 19.2 and 38.4 Kbps • RTS/CTS hardware handshake signals • Connection to DH-485, DeviceNet and Ethernet networks through the 1761-NET-AIC, 1761-NET-DNI and 1761-NET-ENI interface modules, respectively (MicroLogix 1500 controllers also connect to DeviceNet network via the 1769-SDN DeviceNet Scanner Module) • Connection to modems for remote communication • ASCII messaging provides dial-out capability (except MicroLogix 1000 controller) • DF1 half-duplex slave • DF1 half-duplex master (except MicroLogix 1000 controller) • DNP3 slave (MicroLogix 1400 controller only) • Modbus RTU master/slave through the 1761-NET-AIC module (MicroLogix 1100 and 1400 controllers also connect to Modbus RTU master/slave directly through 1763-NC01 cable to Channel 0) Important: The MicroLogix 1100 and 1400 controllers do not provide 24V DC power for network interface whereas all other MicroLogix controllers do. The 24V DC comms power must be provided externally when 1761-NET-AIC or 1761-NET-ENI or 1761-NET-ENIW modules are used with a MicroLogix 1100 and 1400 controller. MicroLogix 1100 and 1400 controllers provide direct connection to RS-485 networks by using the same pins used by other MicroLogix controllers for 24V DC communication power. Publication 1761-SG001F-EN-P - March 2011 34 Select Communication MicroLogix Controller Network Options (RS-232 unless otherwise noted) If your application requires Use this network • Connection to dial-up modems for remote program maintenance or DF1 full-duplex data collection DF1 half-duplex slave/master • Connection to leased-line or radio modems for use in SCADA DF1 radio modem systems • Remote Terminal Unit (RTU) functions • Program upload, download, and monitoring • Plant-wide and cell-level data sharing with program maintenance DH-485 directly through channel 0 RS-485 port using 1763-NC01 • Data sharing between 32 controllers (1) cable • Peer-to-peer communication DH-485 via the 1761-NET-AIC • Program upload, download, and monitoring (2) Advanced Interface Converter • Compatibility with multiple Allen-Bradley HMI devices • Data sharing between 64 devices DeviceNet network via the 1761-NET-DNI DeviceNet Interface • Better diagnostics for improved data collection and fault detection • Less wiring and reduced start-up time than traditional, hard-wired systems • Program upload, download, and monitoring • Peer-to-peer communication • Connection of low-level multi-vendor devices directly to plant floor controllers (when using the 1769-SDN scanner) • Program upload, download, and monitoring EtherNet/IP network directly through Channel 1 10/100 Mbps • Peer-to-peer communication (3) communication port • E-mail communication EtherNet/IP network via the • 10/100 Base-T port with embedded status indicators 1761-NET-ENI Ethernet Interface or 1761-NET-ENIW Web-Enabled • Web server capability via the 1761-NET-ENIW module (2) Ethernet Interface • Connection to third party devices for remote data collection in a Modbus RTU master/slave directly SCADA system (for example, telephone modems, radio modems, through channel) RS-485 port using (2) and leased lines.) 1763-NC01 cable • Remote Terminal Unit (RTU) functions Modbus RTU slave via the 1761-NET-AIC Advanced Interface (2) Converter Modbus RTU master via the 1761-NET-AIC Advanced Interface (2) Converter (4) DNP3 slave via RS-232 (4) DNP3 over IP (4) Modbus TCP/IP (1) MicroLogix 1100 and 1400 controllers only. (2) MicroLogix 1100 and 1400 controllers do not provide 24V DC power for network interface devices. External 24V DC module power must be supplied. (3) Direct EtherNet/IP connections through MicroLogix 1100 and 1400 controllers provide web server capabilities as well as support for email communication. (4) MicroLogix 1400 controllers only. Publication 1761-SG001F-EN-P - March 2011 Select Communication 35 MicroLogix Network Interface Devices The following information describes the functionality of the MicroLogix interface modules. For most applications, the embedded RS-485 and Ethernet/IP functionality of the MicroLogix 1100 and 1400 communication ports replaces the 1761-NET-AIC, 1761-NET-ENI, and the 1761-NET ENIW (or AIC+, ENI, and ENIW) modules. The network interface devices can be mounted on a panel or DIN rail. AIC+ Advanced Interface Converter (Catalog Number 1761-NET-AIC) The AIC+ is an isolated, RS-232 to RS-485 electrical signal converter for supporting serial, half-duplex, multi-drop protocols, such as: DH-485. DF1 half-duplex master/slave. Modbus RTU (a single master can communicate with a maximum of 31 slave devices). Since RS-232 ports can only be connected point-to-point between two devices, an AIC+ (or similar device) is required whenever a MicroLogix controller is configured for one of these protocols and needs to communicate with more than one other device at a time. The AIC+ also provides electrical isolation between each of its three ports for a more stable network and protection for connected devices. When using the 1763-NC01 cable, the MicroLogix 1100 and 1400 controller provides isolated connection to RS-485 networks directly from the Channel 0 combo port. Any MicroLogix controller can connect to either of the two RS-232 ports on the AIC+. When Channel 0 on a MicroLogix controller is connected to Port 2 (RS-232 8-pin mini-DIN) of the AIC+, the interface module can draw its power from the MicroLogix controller. In all other cases, including using MicroLogix 1100 and 1400 controllers, the AIC+ must be powered from an external, 24V DC power supply. The AIC+ can also be used as an RS-232 to RS-485 converter and port isolator for any other Allen-Bradley controller or terminal with an RS-232 port. Since the AIC+ is not a protocol converter, all devices connected to a single AIC+ (or a network of AIC+s) must be configured for the same communication protocol. DH-485 Network Specifications Attribute 1761-NET-AIC Number of Nodes, max 32 per multidrop network Length, max 1219 m (4000 ft) per multidrop network Publication 1761-SG001F-EN-P - March 2011 36 Select Communication DNI DeviceNet Interface (1761-NET-DNI) DNI capabilities: Peer-to-peer messaging between Allen-Bradley controllers and other devices using the DF1 full-duplex protocol Programming and online monitoring over the DeviceNet network With a DNI connected to a modem, you can dial in to any other DNI-controller combination on DeviceNet Other DeviceNet products can send explicit (Get or Set) messages with the DNI at any time The controller can initiate an explicit message to a UCMM (Unconnected Message Manager) compatible device on DeviceNet DeviceNet Specifications Attribute 1761-NET-DNI Number of Nodes, max 64 Length, max 500 m @ 125 Kbps or 100 m @ 500 Kbps DeviceNet Agency Certification ODVA conformance 2.0-A12 ENI Ethernet Interface (1761-NET-ENI) and ENIW Ethernet Interface with Web Server Capabilities (1761-NET-ENIW) The ENI provides EtherNet/IP connectivity for all MicroLogix controllers and other DF1 full-duplex devices. The ENI lets you easily connect a MicroLogix controller to a new or existing Ethernet network to update/download programs, communicate between controllers, and generate e-mail messages via SMTP (simple mail transport protocol). The ENIW adds web server capabilities, enabling the display of 4 standard data web pages with user-configurable data descriptions, and 10 user-configurable web-page links on the ENIW home page. MicroLogix 1100 and 1400 controllers also provide EtherNet/IP connectivity, web server, and email capabilities directly through Channel 1. Ethernet Specifications Attribute 1761-NET-ENI Communication Rate 100 MHz (series C and D), 10 MHz (series A and B) Connector 100Base-T (series C and D), 10Base-T (series A and B) Publication 1761-SG001F-EN-P - March 2011 Select Communication 37 AIC+, DNI, and ENI /ENIW Specifications Network Modules Specifications Attribute 1761-NET-AIC 1761-NET-DNI 1761-NET-ENI, 1761-NET-ENIW Power Supply DC Voltage 20.4…28.8V DC 11…25V DC 20.4…26.4V DC (1) Range Backplane Current (mA) at 120 mA 200 mA 50 mA 24V Inrush Current, max 200 mA 400 mA 200 mA Isolation Voltage 500V DC for 1 minute 500V DC for one minute 710V DC for one minute Operating Temperature 0…60 °C (32…140 °F) Storage Temperature -40…85 °C (-40…185 °F) Relative Humidity 5…95% noncondensing Vibration operating: 10…500 Hz, 5.0 g, 0.030 in. operating: 5…2000 Hz, 2.5 g, 0.015 in. operating: 10…500 Hz, 5.0 g, 0.030 in. peak-to-peak, 2 hour each axis peak-to-peak, 1 hour each axis peak-to-peak, 2 hour each axis nonoperating: 5…2000 Hz, 5.0g, 0.030 in. peak-to-peak, 1 hour each axis Shock, Operating 30 g, ±3 times each axis 30 g, ±3 times each axis 30 g, ±3 times each axis Shock, Nonoperating 50 g, ±3 times each axis 50 g, ±3 times each axis 35 g (DIN rail mount) 50 g (panel mount) ±3 times each axis Certifications • UL Listed Industrial Control Equipment for use in Class 1, Division 2, Hazardous Locations, Groups A, B, C, D • C-UL Listed Industrial Control Equipment for use in Canada • CE marked for all applicable directives • C-Tick marked for all applicable acts (1) When the device is connected to a MicroLogix 1000, 1200, or 1500 controller, power is provided by the MicroLogix controller’s communication port. Power is not supplied by the MicroLogix 1100 and 1400 controllers. External 24V DC module power must be supplied. Network Interface Devices Dimensions 52.07 mm (2.05 in.) 6.6 mm 118 mm 107 mm (0.26 in.) (4.64 in.) (4.20 in.) AIC+ only Allow 15 mm (0.6 in.) for DIN rail latch movement during installation and re- moval. 64.8 mm (2.55 in.) 27.7 mm 71.4 mm (1.09 in.) (2.81 in.) AIC Publication 1761-SG001F-EN-P - March 2011 38 Select Programming Tools and Software Programming Software Select Programming Tools and Software The RSLogix 500 and RSLogix Micro ladder-logic programming packages help you maximize performance, save project development time, and improve productivity. These products have been developed to operate on Windows operating systems. RSLogix 500 software can be used for programming both the SLC 500 and MicroLogix controller families. RSLogix Micro software is for programming MicroLogix controller families only. Step 3 - Select: RSLogix 500 and RSLogix Micro Selection Chart • programming tools - hand-held programmer with optional memory Cat. No. Description module (available for MicroLogix 1000 only) 9324-RL0100ENE RSLogix 500 Starter Edition Programming Software for MicroLogix controller families. (CD-ROM) • software - the appropriate RSLogix package for your application 9324-RL0300ENE RSLogix 500 Standard Edition Programming Software for SLC 500 and • record your selection in the Selection MicroLogix controller families. (CD-ROM) Record (starts on page 86) 9324-RL0700NXENE RSLogix 500 Professional Edition. CD-ROM also includes RSLogix Emulate 500, RSNetworx for DeviceNet and RSNetworx for ControlNet software. 9324-RLM0100ENE RSLogix Micro Starter software 9324-RLM0800ENE RSLogix Micro Developer software Download Free Lite Version of RSLogix Micro Starter TIP Software Now you can download free RSLogix Micro Starter Lite software and RSLinx Lite software to program, upload, and download all MicroLogix 1000 and MicroLogix 1100 controllers. RSLogix Micro Starter Lite software, when used together with RSLinx Lite software, is fully-functional with all MicroLogix 1000 and MicroLogix 1100 controllers. Go to http:www.ab.com/programmablecontrol/plc/micrologix/downloads.ht ml for details. Hand-Held Programmer (MicroLogix 1000 controller only) The 1761-HHP-B30 lets you create, edit, monitor, and troubleshoot Instruction List (Boolean) programs for your MicroLogix 1000 controller. This device also lets you store programs and to transfer programs through the use of an optional removable memory module. There are 2 memory modules: 1761-HHM-K08 - 8 KB, stores 1 program. 1761-HHM-K64 - 64 KB, stores 8 programs. Publication 1761-SG001F-EN-P - March 2011 Select Network and Programming Cables 39 Cables come in several lengths and connector styles to provide connectivity between Select Network and MicroLogix controllers and other devices. MicroLogix 1200 controllers require series C Programming Cables versions of all 1761 cables. Network Cable Selection Step 4 - Select: • cables - review device port identification to find cable in the selection chart) record your selection in the Selection Record (starts on page 86) Controller and PC Port Identification Device Communication Port Description Connector Type MicroLogix 1000 Communication Port (Channel 0) with 24V DC power for communication device 8-pin Mini DIN RS-232/RS-485 Communication Port (Channel 0, no 24V DC power for communication Interface 8-pin Mini DIN (isolated) Modules) MicroLogix 1100 10/100Mbps EtherNet/IP Communication Port (Channel 1) RJ-45 MicroLogix 1200 Communication Port (Channel 0) with 24V DC power for communication device 8-pin Mini DIN MicroLogix 1200R Programming/HMI Port (no 24V DC power) 8-pin Mini DIN RS-232/RS-485 Communication Port (Channel 0, no 24V DC power for communication Interface 8-pin Mini DIN (isolated) Modules) MicroLogix 1400 10/100Mbps EtherNet/IP Communication Port (Channel 1) RJ-45 Communication Port (Channel 2) 9-pin D Shell MicroLogix 1500 Base Unit Communication Port (Channel 0) with 24V DC power for communication device 8-pin Mini DIN MicroLogix 1500 with Processor Communication Port (Channel 1) 9-Pin D Shell (isolated) 1764-LRP Processor Personal Computer Serial Communication Port 9-Pin D Shell Personal Computer Personal Computer Ethernet Communication Port RJ-45 Network Interface Devices Communication Port Identification AIC+ DNI ENI/ENIW DeviceNet ETHERNET V± RS232 CAN_L FAULT NET SHIELD CAN_H V+ NET MOD DH-485 TX/RX TX/RX RS-232 RS-232 8-Pin Mini DIN 8-Pin Mini DIN Ethernet IP NODE Important: The AIC+ is recommended DANGER PWR for isolation purposes when the con- TX/RX CABLE GND troller and an operator interface device EXTERNAL RS-232 are not using the same power supply. 9-Pin D Shell RS-232 8-Pin Mini DIN Publication 1761-SG001F-EN-P - March 2011 40 Select Network and Programming Cables Network Cable Selection Chart Connectors Length Cat. No. Connectors Length Cat. No. (1) 8-pin Mini DIN to 8-pin Mini DIN 0.5 m (1.5 ft) 8-pin Mini DIN to 9-pin D Shell 5 m (16 ft) 2711-CBL-PM05 1761-CBL-AM00 (1) 8-pin Mini DIN to 8-pin Mini DIN 2 m (6.5 ft) 8-pin Mini DIN to 9-pin D Shell 10 m (32 ft) 2711-CBL-PM10 1761-CBL-HM02 8-pin Mini DIN to 8-pin Mini DIN 5 m (16 ft) 2711-CBL-HM05 6-pin Phoenix to RJ45 (DH-485) 3 m (10 ft) 1761-CBL-AS03 8-pin Mini DIN to 8-pin Mini DIN 10 m (32 ft) 2711-CBL-HM10 6-pin Phoenix to RJ45 (DH-485) 9 m (30 ft) 1761-CBL-AS09 (1) 9-pin D Shell to 9-pin D Shell 0.5 m (1.5 ft) 1761-CBL-AC00 8-pin Mini DIN to 8-pin Mini DIN 15 m (49.2 ft) 2707-NC9 9-pin D Shell to 9-pin D Shell 3 m (10 ft) 1747-CP3 8-pin Mini DIN to 6-pin DH-485 30 cm 1763-NC01 series A terminal (11.8in.) (1) (2) 8-pin Mini DIN to 9-pin D Shell 0.5 m (1.5 ft) RJ-45 to RJ-45 100 m (328 1761-CBL-AP00 Ethernet Cable ft), max (1) 8-pin Mini DIN to 9-pin D Shell 2 m (6.5 ft) 1761-CBL-PM02 (1) Series C or later for Class 1 Div 2 applications. (2) Commercially available. Programming Cable Selection Programming Cable Selection Chart - Programming Device to Controller Programming Device MicroLogix 1000, 1100, 1200, 1400, and 1500 Channel 0 (8-pin Mini DIN) MicroLogix 1400 Channel 2 MicroLogix 1200 Programming/HMI MicroLogix 1500 with 1764-LRP Port MicroLogix 1100 and 1400 Processor (8-pin Mini DIN) Channel 1 (RJ-45) Channel 1 (9-pin RS-232) Cat. No. Length Cat. No. Length Cat. No. Length Personal Computer (9-pin D Shell) 1761-CBL-PM02 2 m (6.5 ft) --- 1747-CP3 3m (10 ft) (1) Personal Computer (RJ-45) --- 100 m (328 --- Ethernet Cable ft), max Hand-Held Programmer (1761-HHP) 1761-CBL-HM02 2 m (6.5 ft) --- --- (1) Commercially available. 1747-UIC Universal Serial Bus to DH-485 Interface Converter This device allows a computer with a USB port to interface to DH-485 ports on an SLC 500, MicroLogix, or other Rockwell Automation controllers and on PanelView terminals. The 1747-UIC features a USB connector as well as both an RS-232 and an RS-485 port. Use the RS-232 port to connect to SLC 5/03, 5/04, 5/05 (Channel 0), MicroLogix, CompactLogix, FlexLogix, ControlLogix controllers, PanelView 300 or higher terminals, or the AIC+ interface. Use the RS-485 port to connect to SLC 5/01, 5/02, 5/03 controllers (Channel 1), PanelView 300 or higher terminals, or the 1747-AIC isolated link coupler. USB to DH-485 Interface Converter Specifications Cat. No. 1747-UIC USB Power Consumption <100 mA (low power) USB Speed USB 1.1 (12 Mbps) DH-485 Baud Rate 19.2 Kbps Publication 1761-SG001F-EN-P - March 2011 Select MicroLogix 1000 Controllers 41 Programming Cable Selection Chart - Programming Device to AIC+ (DH-485 only) Programming Device 1761-NET-AIC (8-pin Mini DIN) to PC via 1747-UIC 1761-NET-AIC (9-pin D Shell) to PC via 1747-UIC Universal Serial Bus to DH-485 Interface Universal Serial Bus to DH-485 Interface Converter Converter Cat. No. Length Cat. No. Length Personal Computer (USB Port) 1761-CBL-PM02 2 m (6.5 ft) 1747-CP3 3 m (10 ft) Select MicroLogix 1000 Controllers MicroLogix 1000 Controller Catalog Number Detail 1761 - L 20 A W A - 5 A Step 5 - Select: Analog I/O Bulletin Number • controller - review power and I/O Analog Circuits: configurations to select a controller Base Unit 4 Inputs, 1 Output catalog number; see power supply and I/O specification for more detailed Number of I/O information Power Supply • record your selection in the Selection A = 120/240V AC Record (start on page 86) Input Type: B = 24V DC A = 120V AC Output Type: B = 24V DC B = 24V DC N = 24V AC or 24V DC W = Relay X = Relay and 24V DC FET MicroLogix 1000 Controller Power and I/O Configuration (1) Cat. No. Line Voltage Number of Inputs High Speed I/O Number of Outputs 1761-L16AWA 120/240V AC (10) 120V AC (6) Relay N/A 1761-L32AWA 120/240V AC (20) 120V AC (12) Relay N/A 1761-L20AWA-5A 120/240V AC (12) 120V AC, (4) Analog (8) Relay, (1) Analog N/A 1761-L32AAA 120/240V AC (20) 120V AC (10) Triac, (2) Relay N/A 1761-L16NWA 120/240V AC (10) 24V AC or DC (6) Relay N/A 1761-L10BWA 120/240V AC (6) 24V DC (4) Relay (1) 6.6 kHz input 1761-L16BWA 120/240V AC (10) 24V DC (6) Relay (1) 6.6 kHz input 1761-L20BWA-5A 120/240V AC (12) 24V DC, (4) Analog (8) Relay, (1) Analog (1) 6.6 kHz input 1761-L32BWA 120/240V AC (20) 24V DC (12) Relay (1) 6.6 kHz input 1761-L10BWB 24V DC (6) 24V DC (4) Relay (1) 6.6 kHz input 1761-L16BWB 24V DC (10) 24V DC (6) Relay (1) 6.6 kHz input 1761-L20BWB-5A 24V DC (12) 24V DC (8) Relay (1) 6.6 kHz input 1761-L32BWB 24V DC (20) 24V DC (12) Relay (1) 6.6 kHz input 1761-L10BXB 24V DC (6) 24V DC (2) MOSFET sourcing, (2) relay (1) 6.6 kHz input 1761-L16BBB 24V DC (10) 24V DC (4) MOSFET sourcing, (2) relay (1) 6.6 kHz input 1761-L32BBB 24V DC (20) 24V DC (10) MOSFET sourcing, (2) relay (1) 6.6 kHz input 1761-L16NWB 24V DC (10) 24V AC or DC (6) Relay N/A (1) Two individually isolated relays per unit. Publication 1761-SG001F-EN-P - March 2011 42 Select MicroLogix 1000 Controllers MicroLogix 1000 Controller Power Supply Specifications Cat. No. Power Supply Power Consumption Power Supply Inrush Current 24V DC Sensor Voltage (max) Power 1761- 120V AC 240V AC 24V DC L16AWA 85…264V AC at 15 VA 21 VA --- 30 A for 8 ms --- 47…63 Hz L20AWA-5A 20 VA 27 VA --- 30 A for 8 ms --- L32AWA 19 VA 25 VA --- 30 A for 8 ms --- L32AAA 16 VA 22 VA --- 30 A for 8 ms --- L16NWA 26 VA 33 VA --- 30 A for 8 ms --- L10BWA 24 VA 32 VA --- 30 A for 8 ms 200 mA, 200 µF capacitance, max L16BWA 26 VA 33 VA --- 30 A for 8 ms 200 mA, 200 µF capacitance, max L20BWA-5A 30 VA 36 VA --- 30 A for 8 ms 200 mA, 200 µF capacitance, max L32BWA 29 VA 36 VA --- 30 A for 8 ms 200 mA, 200 µF capacitance, max L16NWB 20.4…26.4V DC --- --- 5 W 30 A for 4 ms --- L10BXB --- --- 5 W 30 A for 4 ms --- L16BBB --- --- 5 W 30 A for 4 ms --- L10BWB --- --- 5 W 30 A for 4 ms --- L16BWB --- --- 5 W 30 A for 4 ms --- L20BWB-5A --- --- 10 W 50 A for 4 ms --- L32BWB --- --- 7 W 30 A for 4 ms --- L32BBB --- --- 7 W 30 A for 4 ms --- L16NWB --- --- 5 W 30 A for 4 ms --- Publication 1761-SG001F-EN-P - March 2011 Select MicroLogix 1000 Controllers 43 MicroLogix 1000 Controller DC Input Power Requirements Based on I/O Usage 1761-L10BWB Typical Power Requirements 1761-L10BXB, -L16BBB, Typical Power Requirements 6 7 6 5 5 4 4 3 3 2 2 1 1 0 0 024 6 8 10 02468 10 12 14 16 I/O Points Used I/O Points Used 1761-L16BWB Typical Power Requirements 1761-L32BBB Typical Power Requirements 7 10 9 6 8 5 7 6 4 5 3 4 3 2 2 1 1 0 0 02468 10 12 14 16 0 4 8 1216 20 2428 32 I/O Points Used I/O Points Used 1761-L20BWB-5A Typical Power Requirements 1761-L32BWB Typical Power Requirements 10 12 9 10 8 7 8 6 5 6 4 4 3 2 2 1 0 0 0 2 4 6 8 10 121416 1820 0 4 8 1216 20 2428 32 I/O Points Used I/O Points Used Publication 1761-SG001F-EN-P - March 2011 Input Power Required at Input Power Required at Input Power Required at 24Vdc (Watts) 24Vdc (Watts) 24Vdc (Watts) Input Power Required at Input Power Required at Input Power Required at 24Vdc (Watts) 24Vdc (Watts) 24Vdc (Watts) 44 Select MicroLogix 1000 Controllers MicroLogix 1000 Controller Digital Input Specifications Attribute 120/240V AC Controllers 24V DC Controllers 24V AC Controllers On-state Voltage Range 79…132V AC 14…26.4V DC max @ 55 °C (131 °F) 18…26.4V AC @ 55 °C (131 °F) 14…30.0V DC max @ 30 °C (86 °F) 18…30V AC @ 30 °C (86 °F) Off-state Voltage Range 0…20V AC 0…5V DC 0…3V AC (1) 47…63 Hz standard inputs: 1.0 kHz, max 47…63 Hz Operating Frequency high-speed inputs: 6.6 kHz, max Signal Delay, max ON Delay = 20 ms standard inputs: selectable from 0.5 to 16 ms ON Delay = 20 ms, max OFF Delay = 20 ms high-speed inputs: selectable from 0.075 to 16 ms OFF Delay = 20 ms, max On-state Current, min 5.0 mA at 79V AC @ 47 Hz 2.5 mA @ 14V DC 3.0 mA @ 18V AC On-state Current, nom 12.0 mA at 120V AC @ 60 Hz 8.0 mA @ 24V DC 8.0 mA @ 24V AC On-state Current, max 16.0 mA at 132V AC @ 63 Hz 12.0 mA @ 30V DC 12 mA @ 30V AC Off-state Leakage Current, max 2.5 mA 1.5 mA 1.0 mA Impedance, nom 12 kΩ at 50 Hz, 10 kΩ at 60 Hz 3 kΩ 3 kΩ (2) Inrush Current, max --- --- 250 mA, max (1) 1761-L16NWA and 1761-L16NWB controllers do not support high-speed inputs even when using 24V DC inputs. (2) To reduce the inrush maximum to 35 mA, apply a 6.8 kΩ, 5 W resistor in series with the input. The on-state voltage increases to 92V AC as a result. MicroLogix 1000 Controller Digital Output Specifications Attribute Relay FET Triac Operating Voltage Range 5…125V DC 20.4…26.4V DC 85…264V AC 5…264V AC Continuous Current per Point, max See MicroLogix 1500 Controller Relay 1.0 A @ 55 °C (131 °F) 0.5 A @ 55 °C (131 °F) Contact Rating on page 72. 1.5 A @ 30 °C (86 °F) 1.0 A @ 30 °C (86 °F) Continuous Current per Common, max 8.0 A 3 A for L10BBB and L16BBB 6 A 6 A for L32BBB Continuous Current per Controller, max 1440 VA 3 A for L10BBB and L16BBB 1440 VA 6 A for L32BBB On-state Current, min 10.0 mA 1 mA 10.0 mA Off-state Leakage Current, max 0 mA 1 mA 2 mA at 132V AC 4.5 mA at 264V AC Signal Delay, max - resistive load ON Delay = 10 ms ON Delay = 0.1 ms ON Delay = 8.8 ms at 60 Hz OFF Delay = 10 ms OFF Delay = 1 ms ON Delay = 10.6 ms at 50 Hz OFF Delay = 11.0 ms (1) (1) Surge Current per Point (peak) N/A 4 A for 10 ms 10 A for 25 ms (1) Repeatability is once every 2 seconds @ 55 °C (131 °F). MicroLogix 1000 Controller Relay Contact Rating Voltage, max Amperes Amperes Continuous Voltamperes Make Break Make Break 240V AC 7.5 A 0.75 A 2.5 A 1800 VA 180 VA 120V AC 15 A 1.5 A (1) 125V DC 1.0 A 28 VA 0.22 A (1) 24V DC 2.0 A 1.2 A (1) For DC voltage applications, the make/break ampere rating for relay contacts can be determined by dividing 28 VA by the applied DC voltage. For example, 28 VA/48V DC = 0.58 A. For DC voltage applications less than 48V, the make/break ratings for relay contacts cannot exceed 2 A. For DC voltage applications greater than 48V, the make/break ratings for relay contact cannot exceed 1 A. Publication 1761-SG001F-EN-P - March 2011 Select MicroLogix 1000 Controllers 45 MicroLogix 1000 Controller Analog Input Specifications Attribute 1761-L20xxx-5A (1) -10.5…10.5V DC Voltage Input Range (1) -21…21 mA Current Input Range Input Coding (-21…21 mA, -10.5…10.5V DC) -32,768…32,767 Voltage Input Impedance 210 kΩ Current Input Impedance 160 Ω (2) 16-bit Input Resolution Non-linearity < 0.002% Overall Accuracy 0…55 °C (32…131 °F) ±0.7% of full scale Overall Accuracy Drift 0…55 °C (32…131 °F), max ±0.176% Overall Accuracy at 25 °C (77 °F), max ±0.525% Update Time selectable from 4…100 ms Voltage Input Overvoltage Protection 24V DC Current Input Overcurrent Protection ±50 mA Input to Output Isolation and Field Wiring to Logic Isolation 30V rated working voltage, 500V isolation (test 60 Hz for 1 s) (1) The two voltage inputs accept ±10.5V DC. The two current inputs accept ±21 mA. (2) The analog input update rate and input resolution are a function of the input filter selection. MicroLogix 1000 Controller Analog Output Specifications Attribute Value (1) 0…10V DC Voltage Output Range (1) 4…20 mA Current Output Range Non-linearity 0.02% Step Response 2.5 ms (at 95%) Load Range - Voltage Output 1 kΩ…∞ Ω Load Range - Current Output 0…500 Ω Output Coding (4…20 mA, 0…10V DC) 0…32,767 Voltage Output Miswiring and Current Output Miswiring can withstand short circuit Output Resolution 15-bit Analog Output Settling Time 3 msec, max Overall Accuracy 0…55°C ±1.0% of full scale Overall Accuracy Drift 0…55 °C, max ±0.28% Overall Accuracy at +25 °C (+77 °F), max - Current Output 0.2% Field Wiring to Logic Isolation 30V rated working/500V isolation (1) The analog output can be configured for either voltage (0V DC...10V DC) or current (4...20 mA). Publication 1761-SG001F-EN-P - March 2011 46 Select MicroLogix 1100 Controllers MicroLogix 1100 Base Units Select MicroLogix 1100 Controllers The base unit houses embedded inputs, outputs, power supply, and communication ports. The base unit also provides the interface to expansion I/O when required by an application. Step 6 - Select: MicroLogix 1100 Controller Catalog Number Detail • controller - review power and I/O configurations to select a controller 1763 - L 16 A W A catalog number; see power supply and I/O specification for more detailed Power Supply information Bulletin Number A = 120/240V AC • accessories - memory modules B = 24V DC • record your selection in the Selection Base Unit D = 12...24V DC Record (starts on page 86) Number of I/O Output Type: B = Relay/24V DC W = Relay Input Type: A = 120V AC B = 24V DC D = 12...24V DC MicroLogix 1100 Controller Power and I/O Configuration Cat. No. Line Voltage Number of Inputs Number of Outputs High Speed I/O 1763-L16AWA 120/240V AC (10) 120V AC (6) Individually Isolated None (2) Analog Voltage Relay 1763-L16BWA 120/240V AC (6) 24V DC (6) Individually Isolated (4) 40 kHZ input (4) Fast 24V DC Relay (2) Analog Voltage 1763-L16BBB 24V DC (6) 24V DC (2) Individually Isolated (4) 40 kHZ input (4) Fast 24V DC Relay (2) 40 kHZ output (2) Analog Voltage (2) 24V DC FET (2) Fast 24V DC FET 1763-L16DWD 12...24V DC (6) 12V DC/24V DC (6) Individually Isolated (4) 40 kHZ input (4) Fast 12V DC/24V Relay DC (2) Analog Voltage MicroLogix 1100 Controller Power Supply Specifications Attribute 1763-L16AWA 1763-L16BWA 1763-L16BBB 1763-L16DWD Power Supply Voltage 85…264V AC @ 47…63 Hz 20.4…26.4V DC Class 2 12…24V DC (-15%, 10%) SELV Class 2 SELV Power Consumption 46 VA 52 VA 6...30 W 6...30 W Power Supply Inrush 120V AC: 25 A for 8 ms 24V DC: 15 A for 20 ms 24V DC: 15 A for 20 ms Current, max 240V AC: 40 A for 4 ms 24V DC Sensor Power --- 250 mA, 400µF --- --- capacitance, max Publication 1761-SG001F-EN-P - March 2011 Select MicroLogix 1100 Controllers 47 MicroLogix 1100 Controller DC Input Power Requirements for 1763-L16BBB and 1763-L16DWD Units 30 24 18 12 6 0 04 8 12 16 20 Calculated Load Power (Watts) MicroLogix 1100 Controller Digital Input Specifications 1763-L16BWA and 1763-L16BBB 1763-L16DWD Attribute 1763-L16AWA Inputs 0...3 Inputs 4 and higher Inputs 0...3 Inputs 4 and higher On-state Voltage Range 79…132V AC @ 14…26.4V DC @ 10…26.4V DC @ 10…24V DC @ 65 °C (149 °F) 47…63 Hz 65 °C (149 °F) 65 °C (149 °F) 10…30V DC @ 30 °C (86 °F) 14…30.0V DC @ 10…30.0V DC @ 30 °C (86 °F) 30 °C (86 °F) Off-state Voltage Range 0…20V AC 0…5V DC 0…5V DC (1) Operating Frequency 47…63 Hz 0 Hz…1 kHz 0 Hz…40 kHz 0 Hz…1 kHz 0 Hz…40 kHz Signal Delay, max On Delay = 20 ms standard inputs: selectable from 0.5…16 ms standard inputs: selectable from 0.5…16 ms Off Delay = 20 ms high-speed inputs: selectable from 0.0125…16 ms high-speed inputs: selectable from 0.0125…16 ms On-state Current min 5.0 mA @ 79V AC 2.5 mA @ 14V DC 2.0 mA @ 10V DC 2.0 mA @ 10V DC nom 12 mA @ 120V AC 8.8 mA @ 24V DC 8.5 mA @ 24V DC 8.5 mA @ 24V DC max 16.0 mA @ 132V AC 12.0 mA @ 30V DC 12.0 mA @ 30V DC 12.0 mA @ 30V DC Off-state Leakage 2.5 mA, max 1.5 mA, min 1.5 mA, min Current, max Impedance, nom 12 kΩ @ 50 Hz 3.1 kΩ 2.61 kΩ 3.1 kΩ 10 kΩ @ 60 Hz Inrush Current, max 250 mA @ 120V AC --- --- (1) OS series B FRN 4 or later. MicroLogix 1100 Controller Digital Output Specifications 1763-L16AWA, 1763-L16BBB 1763-L16BWA, and 1763-L16DWD FET Standard FET High-speed Operation Operation (Output 2 and 3 Attribute Relay only) Operating Voltage 5…125V DC 20.4…26.4V DC Range 5…264V AC Continuous Current per See MicroLogix 1100 See MicroLogix 100 mA Point, max Controller Relay 1100 Controller Contact Rating on page FET Standard 48. Outputs Continuous Current per Point, max on page 49 Continuous Current per 5 A/3 A Common, max Publication 1761-SG001F-EN-P - March 2011 Input Power Required (Watts) 48 Select MicroLogix 1100 Controllers MicroLogix 1100 Controller Digital Output Specifications 1763-L16AWA, 1763-L16BBB 1763-L16BWA, and 1763-L16DWD FET Standard FET High-speed Operation Operation (Output 2 and 3 Attribute Relay only) Continuous Current per 30 A or total of per-point loads, whichever is less at 150V, max Controller, max 20 A or total of per-point loads, whichever is less at 240V, max On-state Current, min 10.0 mA 1 mA 10.0 mA Off-state Leakage 0 mA 1 mA Current, max Signal Delay, max - On Delay = 10 ms On Delay = 0.1 ms On Delay = 6 µs resistive load Off Delay = 10 ms Off Delay = 1.0 ms Off Delay = 18 µs Surge Current per Point --- 4 A for 10 ms (repeatability is once every 2 s @ (peak) 65 °C (149 °F), once every 1 s @ 30 °C (86 °F) MicroLogix 1100 Controller Analog Input Specifications Attribute 1763-L16AWA, 1763-L16BWA, 1763-L16BBB, 1763-L16DWD Voltage Input Range 0…10V DC Input Coding (0…10V DC) 0…1023 Voltage Impedance 210 kΩ Input Resolution 10-bit Non-linearity (in percent full scale) ±0.5% Overall Accuracy ±0.5% full scale at -20…65 °C (-4…149 °F) Update Time 100/20/16.67/4 ms (selectable) Voltage Input Overvoltage Protection 10.5V DC Field Wiring to Logic Isolation Non-isolated with logic MicroLogix 1100 Controller Relay Contact Rating Amperes Voltamperes Amperes Voltage, max Make Break Continuous Make Break 240V AC 15.0 A 1.5 A 5.0 A/3.0 A 3600 VA 360 VA 120V AC 30 A 3.0 A 125V DC 0.22 A 1.0 A 28 VA 24 V DC 1.2 A 2.0 A Publication 1761-SG001F-EN-P - March 2011 Select MicroLogix 1100 Controllers 49 MicroLogix 1100 Controller FET Standard Outputs Continuous Current per Point, max FET Current per Point FET Total Current (1763-L16BBB) (1763-L16BBB) 2.0 4.0 1.75 3.5 1.5A, 30°C (86°F) 3.0A, 30°C (86°F) 1.5 3.0 1.25 2.5 1.0 2.0 1.5A, 70°C (158°F) 0.75A, 70°C (158°F) 0.75 1.5 0.5 1.0 0.25 0.5 10°C 30°C 50°C 70°C 80°C 10°C 30°C 50°C 70°C 80°C (50°F) (86°F) (122°F) (158°F) (176°F) (50°F) (86°F) (122°F) (158°F) (176°F) Temperature Temperature Publication 1761-SG001F-EN-P - March 2011 Current (Amps) Current (Amps) 50 Select MicroLogix 1100 Expansion I/O MicroLogix 1100 Memory Module (1763-MM1) The controller is shipped with a memory module port cover in place. You can order the memory module to provide removable backup of your User Program and User Data, or to transport your program between controllers. Memory modules allow: user programs and data to be store as backup. transport programs for use with other controllers. special safety/security features for pres s control and other critical applications. auto-recovery, through a power cycle, after a controller fault. comparison of programs. data file and memory module write protection. removal/insertion under power. MicroLogix 1100 controllers expand by using the same 1762 I/O platform as MicroLogix 1200 Select MicroLogix 1100 controllers. The 1762 I/O expansion modules provide superior functionality in a small sized Expansion I/O low-cost package. A variety of modules complement and extend the capabilities of MicroLogix 1100 controllers by maximizing the flexibility of I/O count and type. The MicroLogix 1100 system design allows modules to be either DIN-rail or panel mounted. The DIN latches and screw mounting holes are an integral part of the package design. Step 7 - Select: Controller I/O can be expanded by using up to four 1762 I/O modules. • I/O modules - digital, analog, and temperature • record your selections in the Selection Record (start on page 86) Advantages Rackless design, eliminating added system costs and inventory Small footprint with high density I/O, minimizing panel space requirements Integral high-performance I/O bus Software keying to prevent incorrect positioning within the system Feature-rich I/O functionality addresses a wide range of applications AC/DC relay, 24V DC, 120V AC and 240V AC voltages Thermocouple/mV and RTD/Resistance temperature input modules Publication 1761-SG001F-EN-P - March 2011 Select MicroLogix 1100 Expansion I/O 51 Available Modules 1762 Expansion I/O Modules Cat. No. Description Digital 1762-IA8 8-Point 120V AC Input Module 1762-IQ8 8-Point Sink/Source 24V DC Input Module 1762-IQ8OW6 8 Point Sink/Source 24V DC Input/6-Point AC/DC Relay Output Combination Module 1762-IQ16 16-Point Sink/Source 24V DC Input Module 1762-OA8 8-Point 120/240V AC Triac Output Module 1762-OB8 8-Point Sourcing 24V DC Output Module 1762-OB16 16-Point Sourcing 24V DC Output Module 1762-OW8 8-Point AC/DC Relay Output Module 1762-OW16 16-Point AC/DC Relay Output Module 1762-OX6I 6-Point Isolated AC/DC Relay Output Module 1762-OV32T 32-Point Solid State 24V DC Sink Output Module 1762-OB32T 32-Point Solid State 24V DC Source Output Module 1762-IQ32T 32-Point DC Input Module Analog 1762-IF4 4-Channel Voltage/Current Analog Input Module 1762-OF4 4-Channel Voltage/Current Analog Output Module 1762-IF2OF2 Combination 2-Channel Input 2-Channel Output Voltage/Current Analog Module Specialty 1762-IR4 4-Channel RTD/Resistance Input Module 1762-IT4 4-Channel Thermocouple/mV Input Module Publication 1761-SG001F-EN-P - March 2011 52 Select MicroLogix 1100 Expansion I/O 1762 Digital I/O 1762 Digital Expansion Input Modules Specifications Attribute 1762-IA8 1762-IQ8 1762-IQ8OW6 (inputs) 1762-IQ16 1762-IQ32T (1) (1) (1) (1) Voltage Category 100/120V AC 24V DC (sink/source) 24V DC (sink/source) 24V DC (sink/source) 24V DC sink/source Operating Voltage 79…132V AC 10…26.4V DC 10…26.4V DC 10…26.4V DC 10...26.4V DC (3)(2) Range @ 47…63 Hz @ 55 °C (131 °F) @ 65 °C (149 °F) 10...30V DC 10…30V DC 10…30V DC 10…30V DC @ 30 °C (86 °F) @ 30 °C (86 °F) Number of Inputs 8 8 8 16 32 Number of Commons 1 1 inputs: 2 24 outputs: 1 Bus Current Draw, 50 mA @ 5V DC (0.25 50 mA @ 5V DC (0.25 110 mA @ 5V DC (0.55 70 mA @ 5V DC (0.35 170 mA @ 5V DC (3) max W) W) W) 0 mA @ 24V DC W) 80 mA @ 24V DC (1.92 W) Heat Dissipation, 2.0 Total Watts 3.7 Total Watts 5.0 Total Watts @ 30V 5.4 Total Watts @ 30V 5.4 Total Watts @ 26.4V max 4.4 Total Watts @ 26.4V 4.3 Total Watts @ 6.8 Total Watts @ 30.0V (3) 26.4V Signal Delay, max On Delay: 20.0 ms On Delay: 8.0 ms On Delay: 8.0 ms On Delay: 8.0 ms On Delay: 8.0 ms Off Delay: 20.0 ms Off Delay: 8.0 ms Off Delay: 8.0 ms Off Delay: 8.0 ms Off Delay: 8.0 ms Off-state Voltage, 20V AC 5V DC 5V DC 5V DC 5V DC max Off-state Leakage 2.5 mA 1.5 mA 1.5 mA 1.5 mA 1.0 mA Current, max On-state Voltage, 79V AC, min, 132V AC, 10V DC 10V DC 10V DC 10V DC min max On-state Current min 5.0 mA @ 79V AC 47 Hz 2.0 mA @ 10V DC 2.0 mA @ 10V DC 2.0 mA @ 10V DC 1.6 mA @ 10V DC (min) nom 12.0 mA @ 120V AC 60 8.0 mA @ 24V DC 8.0 mA @ 24V DC 8.0 mA @ 24V DC 2 mA @ 15V DC (min) max Hz 12.0 mA @ 30V DC 12.0 mA @ 30V DC 12.0 mA @ 30V DC 5.7 mA @ 26.4V DC (max) 16.0 mA @ 132V AC 63 6.5 mA @ 30.0V DC (max) Hz Inrush Current, max 250 mA --- 250 mA --- -- Publication 1761-SG001F-EN-P - March 2011 Select MicroLogix 1100 Expansion I/O 53 Attribute 1762-IA8 1762-IQ8 1762-IQ8OW6 (inputs) 1762-IQ16 1762-IQ32T Impedance, nom 12 kΩ @ 50 Hz 3 kΩ 3 kΩ 3 kΩ 4.7 kΩ 10 kΩ @ 60 Hz Isolated Groups Group 1: inputs 0…7 Group 1: inputs 0…7 Group 1: inputs 0…3 Group 1: inputs 0…7 Group 1: Inputs 0...7 (internally connected (internally connected Group 2: inputs 4…7 Group 2: inputs 8…15 Group 2 : Inputs 8...15 commons) commons) Group 3: outputs 0…5 Group 3 : Inputs 16...23 Group 4 : Inputs 24...31 Input Group to Verified by one of the Verified by one of the Verified by one of the Verified by one of the Verified by one of the Backplane Isolation following dielectric following dielectric following dielectric following dielectric following dielectric tests: tests: tests: tests: tests: 1,200V AC for 2 s or 1517V AC for 1 s or 1200V AC for 1 s or Input Group to Backplane 1200V AC for 1 s or 1,697V DC for 2 s 2145V DC for 1 s 1697V DC for 1 s isolation - 1200V AC for 1697V DC for 1 s 75V DC working voltage 132V AC working 75V DC working voltage 1 s or 1697V DC for 1 s 75V DC working (IEC Class 2 reinforced voltage (IEC Class 2 (IEC Class 2 reinforced 75V DC working voltage voltage (IEC Class 2 insulation) reinforced insulation) insulation) (IEC Class 2 reinforced reinforced insulation) insulation) Output Group to Backplane isolation - 1836V AC for 1 s or 2596V DC for 1 s 265V AC working voltage (IEC Class 2 reinforced insulation) Input Group to Output Group isolation - 1836V AC for 1 s or 2596V DC for 1 s 265V AC working voltage (basic insulation) 150V AC working voltage (IEC Class 2 reinforced insulation) (1) Sinking/Sourcing Inputs - Sourcing/sinking describes the current flow between the I/O module and the field device. Sourcing I/O circuits supply (source) current to sinking field devices. Sinking I/O circuits are driven by a current sourcing field device. Field devices connected to the negative side (DC Common) of the field power supply are sinking field devices. Field devices connected to the positive side (+V) of the field supply are sourcing field devices. (2) Refer to Publication 1762-IN10, MicroLogix 1762-IQ16 DC Input Module Installation Instructions, for the derating chart. (3) Only applicable to Series B I/O modules Publication 1761-SG001F-EN-P - March 2011 54 Select MicroLogix 1100 Expansion I/O 1762 Digital Expansion Output Modules Specifications Attribute 1762-OA8 1762-OB8 1762-OB16 1762-OB32T 1762-OV32T Voltage Category 100…240V AC 24V DC 24V DC 24V DC source 24V DC sink Operating Voltage Range 85…265V AC @ 20.4…26.4V DC 20.4…26.4V DC 10.2...26.4V DC 47…63 Hz Number of Outputs 8 8 16 32 Number of Commons 2 1 1 2 Bus Current Draw, max 115 mA @ 5V DC 115 mA @ 5V DC (0.575 175 mA @ 5V DC (0.88 175 mA @ 5V DC (0.575 W) W) W) 0 mA @ 24V DC Heat Dissipation, max 2.9 Total Watts 1.61 Total Watts 2.9 Total watts @ 30 °C 3.4W @ 26.4V DC 2.7 W @ 26.4 V DC (86 °F) 2.1 Total watts at 55 °C (131 °F) Signal Delay, max - On Delay: 1/2 cycle On Delay: 0.1 ms On Delay: 0.1 ms On Delay: 0.5 ms resistive load Off Delay: 1/2 cycle Off Delay: 1.0 ms Off Delay: 1.0 ms Off Delay: 4.0 ms Off-state Leakage, max 2 mA @ 132V 1.0 mA 1.0 mA 0.1 mA @ 26.4V DC 2.5 mA @ 265V On-state Current, min 10 mA 1.0 mA 1.0 mA 1.0 mA On-state Voltage Drop, 1.5V @ 0.5 A 1.0V DC 1.0Vdc 0.3V DC @ 0.5 A max Continuous Current per 0.25 A @ 55 °C (131 0.5 A @ 55 °C (131 °F) 0.5 A @ 55 °C (131 °F) 0.5 A @ 60 °C (140 °F) Point, max °F) 1.0 A @ 30 °C (86 °F) 1.0 A @ 30 °C (86 °F) 0.5 A @ 30 °C (86 °F) Continuous Current per 1.0 A @ 55° (131 °F) 4.0 A @ 55 °C (131 °F) 4.0 A @ 55 °C (131 °F) 2.0 A @ 60 °C (140 °F) Common, max 2.0 A @ 30 °C (86 °F) 8.0 A @ 30 °C (86 °F) 8.0 A @ 30 °C (86 °F) Continuous Current per 2.0 A @ 55 °C (131 4.0 A @ 55 °C (131 °F) 4.0 A @ 55 °C (131 °F) 4.0 A @ 60 °C (140 °F) Module, max °F) 8.0 A @ 30 °C (86 °F) 8.0 A @ 30 °C (86 °F) 4.0 A @ 30 °C (86 °F) (1) (2) (2) Surge Current, max 2.0 A (Repeatable every 2 s @ 60 °C (140 °F) for 5.0 A 2.0 A 2.0 10 ms) (1) Repeatability is once every 2 seconds for a durations of 25 ms. (2) Repeatability is once every 2 seconds @ 55 °C (131 °F), once every second @ 30 °C (86 °F) for a duration of 10 ms. Publication 1761-SG001F-EN-P - March 2011 Select MicroLogix 1100 Expansion I/O 55 1762 Digital Expansion Relay Output Modules Specifications Attribute 1762-IQ8OW6 (outputs) 1762-OW8 1762-OW16 1762-OX6I Voltage Category AC/DC normally open relay AC/DC normally open relay AC/DC normally open relay AC/DC Type C Relay Operating Voltage Range 5…265V AC 5…265V AC 5…265V AC 5…265V AC 5…125V DC 5…125V DC 5…125V DC 5…125V DC Number of Outputs 6 8 16 6 (N.C., N.O.) Number of Commons inputs: 2 226 outputs: 1 Bus Current Draw, max 110 mA @ 5V DC (0.55 W) 80 mA @ 5V DC (0.40 W) 140 mA @ 5V DC (0.70 W) 110 mA @ 5V DC (0.55 W) 80 mA @ 24V DC (1.92 W) 90 mA @ 24V DC (2.16 W) 180 mA @ 24V DC (4.32 110 mA @ 24V DC (2.64 (1) W) W) (1) Heat Dissipation, max 5.0 Total Watts @ 30V 2.9 Total Watts 2.8 Watts 6.1 Watts 4.4 Total Watts @ 26.4V Signal Delay, max - resistive load On Delay: 10 ms On Delay: 10 ms On Delay: 10 ms On Delay: 10 ms Off Delay: 10 ms Off Delay: 10 ms Off Delay: 10 ms Off Delay: 20 ms Off-state Leakage, max 0 mA 0 mA 0 mA 0 mA On-state Current, min 10 mA @ 5V DC 10 mA @ 5V DC 10 mA 100 mA On-state Voltage Drop, max N/A N/A N/A N/A Continuous Current per Point, max 2.5 A (Also see MicroLogix 1500 Controller Relay Contact Rating on page 72.) 7 A (Also see MicroLogix 1500 Controller Relay Contact Rating on page 72.) Continuous Current per Common, max 8 A 8 A 8 A 7 A (Also see MicroLogix 1500 Controller Relay Contact Rating on page 72.) Continuous Current per Module, max 8 A 16 A 16 A 30 A Surge Current, max See MicroLogix 1500 Controller Relay Contact Rating on page 72. (1) Only applicable to Series B I/O modules 1762 Analog Modules 1762 Analog Expansion Modules Common Specifications Attribute 1762-IF4 1762-IF2OF2 1762-OF4 Bus Current Draw, max 40 mA @ 5V DC 40 mA @ 5V DC 40 mA @ 5V DC 50 mA @ 24V DC 105 mA @ 24V DC 165 mA @ 24V DC Analog Normal Operating Range Voltage: -10…10V DC Voltage: 0…10V DC Voltage: 0…0V DC Current: 4…20 mA Current: 4…20 mA Current: 4…20 mA (1) Voltage: -10.5…10.5V DC Voltage: 0…0.5V DC Voltage: 0…0.5V DC Full Scale Analog Ranges Current: -21…21 mA Current: 0…21 mA Current: 0…21 mA (2) Resolution 12 bits (unipolar) 12 bits (unipolar) 15 bits (bipolar) (3) (2) (2) (2) Repeatability ±0.12% ±0.12% ±0.12% (4) Input and Output Group to 30V AC/30V DC rated working voltage 30V AC/30V DC rated working voltage System Isolation (IEC Class 2 reinforced insulation) (N.E.C. Class 2 required) type test: 500V AC or 707V DC for 1 minute (IEC Class 2 reinforced insulation) type test: 500V AC or 707V DC for 1 minute (1) The over- or under-range flag is set when the normal operating range is exceeded. The module continues to convert the analog input up to the maximum full scale range. (2) Only applicable to Series B I/O modules. (3) Repeatability is the ability of the input module to register the same reading in successive measurements for the same input signal. Publication 1761-SG001F-EN-P - March 2011 56 Select MicroLogix 1100 Expansion I/O (4) Rated working voltage is the maximum continuous voltage that can be applied at the terminals with respect to Earth ground. 1762 Analog Expansion Input Modules Specifications Attribute 1762-IF4 1762-IF2OF2 Number of Inputs 4 differential (bipolar) 2 differential (unipolar) Update Time (typical) 130, 250, 290, 450, 530 ms (selectable) 2.5 ms A/D Converter Type Successive approximation Successive approximation (1) ±27V ±27V Common Mode Voltage Range (2) > 55 dB @ 50 and 60 Hz > 55 dB @ 50 and 60 Hz Common Mode Rejection (2) (2) Non-linearity (in percent full scale) ±0.12% ±0.12% (3) (4) (4) Typical Overall Accuracy ±0.32% full scale @ -20…65 °C (-4…149 °F) ±0.55% full scale @ -20…65 °C (-4…149 °F) ±0.24% full scale @ 25 °C (77 °F) ±0.3% full scale @ 25 °C (77 °F) Input Impedance Voltage Terminal: 200 kΩ, Current Terminal: 275 Ω Voltage Terminal: 200 kΩ, Current Terminal: 250 Ω Current Input Protection ±32 mA ±32 mA Voltage Input Protection ±30V ±30V Channel Diagnostics Over or under range or open circuit condition by bit reporting for analog inputs. (1) For proper operation, both the plus and minus input terminals must be within ±27V of analog common. (2) V = 1 V AC. cm pk-pk (3) V = 0 (includes offset, gain, non-linearity and repeatability error terms). cm (4) Only applicable to Series B I/O modules 1762 Analog Expansion Output Modules Specifications Attribute 1762-IF2OF2 1762-OF4 (2) Number of Outputs 2 single-ended (unipolar) 4 single-ended (unipolar) Update Time (typical) 4.5 ms 2.5 ms D/A Converter Type Resistor string R-2R Ladder Voltage Switching Resistive Load on Current Output 0…500 Ω (includes wire resistance) 0…500 Ω (includes wire resistance) Load Range on Voltage Output > 1 kΩ > 1 kΩ Reactive Load, Current Output < 0.1 mH < 0.1 mH Reactive Load, Voltage Output < 1 μF< 1 μF (1) (2) (2) Typical Overall Accuracy ±1.17% full scale @ -20…65 °C (-4…149 °F) , ±1.17% full scale @ -20…65 °C (-4…149 °F) ±0.5% full scale @ 25 °C (77 °F) ±0.5% full scale @ 25°C Output Ripple, range 0…500 Hz < ±0.1% < ±0.1% (referred to output range) (2) (2) Non-linearity (in percent full scale) < ±0.59% < ±0.59% Open and Short-circuit Protection Continuous Continuous Output Protection ±32 mA ±32 mA (1) Includes offset, gain, non-linearity and repeatability error terms. (2) Only applicable to Series B I/O modules. Publication 1761-SG001F-EN-P - March 2011 Select MicroLogix 1100 Expansion I/O 57 1762 Temperature Input Modules Use these modules as a cost effective means of addressing process applications that require temperature measurement and control. Each channel can be individually configured by using RSLogix 500 programming software. On-screen configuration lets you choose the input type, filtering frequency, data format, and status data. On-board scaling is also provided. 1762 Temperature Expansion Input Modules Specifications Attribute 1762-IT4 1762-IR4 Bus Current Draw, max 40 mA @ 5V DC 40 mA @ 5V DC 50 mA @ 24V DC 50 mA @ 24V DC Number of Channels 4 input channels plus a CJC sensor 4 input channels Accepted Inputs Thermocouples Types: J, K, T, E, R, S, B, N, C RTDs: Platinum (385 and 3916), Copper (426), Nickel (672 Millivolt Input Ranges: ±50 mV and ±100 mV and 618), Nickel-Iron (518) Resistance Ranges: 0…3000 Ω Filter Frequency 10 Hz…1 kHz 10 Hz…1 kHz Temperature Units °C or °F °C or °F Data Formats Raw/Proportional, Engineering Units, Engineering Units x 10, Scaled-for-PID, Percent Range Accuracy at 25 °C (77 °F) Thermocouple Inputs: ±0.5…±3.0 °C (±0.9…±5.4 °F) With Autocalibration enabled… depending on thermocouple type RTD Inputs: ±0.2…±0.6 °C (±0.36…±1.08 °F) depending on Millivolt Inputs: ±15…±20 mV RTD type Resistance Inputs: ±0.5…±1.5 Ω depending on resistance value Accuracy at 0…55 °C ±0.8…±10 °C (±1.5…±18 °F) depending on thermocouple With Autocalibration enabled… (32…131 °F) type RTD Inputs: ±0.4…±1.1 °C (±0.72…±1.98 °F) depending on Millivolt Inputs: ±25…±30 mV RTD type Resistance Inputs: ±0.25…±2.5 Ω depending on resistance value Channel Update Time (typical) 7…303 ms per enabled channel + CJC update time, 6…303 ms per enabled channel, depending on filter depending on filter selection (CJC update time is equal to selection the largest enabled channel’s update time.) Channel Diagnostics Over- or under-range and open-circuit by bit reporting Over- or under-range or broken input by bit reporting Calibration The module performs autocalibration on channel enable and on a configuration change between channels. You can also program the module to calibrate every five minutes. Common Mode Noise 115 dB min @ 50 Hz (with 10 Hz or 50 Hz filter) 110 dB min @ 50 Hz (with 10 or 50 Hz filter) Rejection 115 dB min @ 60 Hz (with 10 Hz or 60 Hz filter) 110 dB min @ 60 Hz (with 10 or 60 Hz filter) Normal Mode Noise Rejection 85 dB min @ 50 Hz (with 10 Hz or 50 Hz filter) 70 dB min @ 50 Hz (with 10 or 50 Hz filter) 85 dB min @ 60 Hz (with 10 Hz or 60 Hz filter) 70 dB min @ 60 Hz (with 10 or 60 Hz filter) Input Group to System Isolation 720V DC for 1 minute 707V DC for 1 minute Channel-to-Channel Isolation ±10V DC ±10V DC (1) Thermocouples at 25 °C (77 °F) and 10 Hz filter selected: ±0.1 °C (±0.18 °F) for Nickel and Nickel-Iron Repeatability ±0.1…±2.0 °C (±0.18…±3.6 °F) depending on ±0.2 °C (±0.36 °F) for other RTD inputs thermocouple type ±0.04 Ω for 150 Ω resistances ±0.2 Ω for other resistances Millivolt Inputs: ±6 µV Input Impedance >10 MΩ >10 MΩ (1) Repeatability is the ability of the input module to register the same reading in successive measurements for the same input signal. Publication 1761-SG001F-EN-P - March 2011 58 Select MicroLogix 1200 Controllers MicroLogix 1200 Controllers Catalog Number Detail Select MicroLogix 1200 Controllers 1762 - L 24 A W A R Bulletin Number Programming/HMI Port Step 8 - Select: R = Equipped Base Unit None = Not Equipped • controller - review power and I/O configurations to select a controller catalog Number of I/O Power Supply number; see power supply and I/O specifications for more detailed information A = 120/240V AC Input Type: • accessories - memory and real-time clock B = 24V DC modules A = 120V AC Output Type: B = 24V DC • record your selections in the Selection Record W = Relay (start on page 86) X = Relay/24V DC FET MicroLogix 1200 Controller Power and I/O Configuration Cat. No. Line Voltage Number of Inputs Number of Outputs High Speed I/O 1762-L24AWA, -L24AWAR 120/240V AC (14) 120V AC (10) Relay N/A 1762-L40AWA, -L40AWAR 120/240V AC (24) 120V AC (16) Relay N/A 1762-L24BWA, -L24BWAR 120/240V AC (10) Standard 24V DC (10) Relay (4) 20 kHz input (4) Fast 24V DC 1762-L40BWA, -L40BWAR 120/240V AC (20) Standard 24V DC (16) Relay (4) 20 kHz input (4) Fast 24V DC 1762-L24BXB, -L24BXBR 24V DC (10) Standard 24V DC (5) Relay (4) 20 kHz input (4) Fast 24V DC (4) Standard 24V DC FET (1) 20 kHz output (1) Fast 24V DC FET 1762-L40BXB, -L40BXBR 24V DC (20) Standard 24V DC (8) Relay (4) 20 kHz input (4) Fast 24V DC (7) Standard 24V DC FET (1) 20 kHz output (1) Fast 24V DC FET MicroLogix 1200 Controller Power Supply Specifications Attribute 1762- L24AWA, L40AWA, L24BWA, L40BWA, L24BXB, L40BXB, L24AWAR L40AWAR L24BWAR L40BWAR L24BXBR L40BXBR Power Supply Voltage 85…265V AC @ 47…63 Hz 20.4…26.4V DC Class 2 SELV Power Consumption 68 VA 80 VA 70 VA 82 VA 27 W 40 W Power Supply Inrush 120V AC: 25 A for 8 ms 24V DC: 24V DC: Current, max 240V AC: 40 A for 4 ms 15 A for 20 ms 15 A for 30 ms (1) 5V DC 400 mA 600 mA 400 mA 600 mA 400 mA 600 mA Load Current , max 24V DC 350 mA 500 mA 350 mA 500 mA 350 mA 500 mA Load Power, max 10.4 W 15 W 12 W 16 W 10.4 W 15 W 24V DC Sensor Power --- --- 250 mA, 400 µF 400 mA, 400 µF --- --- capacitance, max capacitance, max (1) See Perform MicroLogix 1200 Controller System Expansion Calculations on page 62 for an example system validation worksheet to calculate expansion I/O power usage. Publication 1761-SG001F-EN-P - March 2011 Select MicroLogix 1200 Controllers 59 MicroLogix 1200 Controller DC Input Power Requirements for BXB Units 1762-L24BXB, 1762-L24BXBR Typical Power Requirements 1762-L40BXB, 1762-L40BXBR Typical Power Requirements 20 30 25 15 20 10 15 10 5 5 0 0 02 46 8 10 02468 10 12 14 Calculated Load Power (Watts) Calculated Load Power (Watts) MicroLogix 1200 Controller Input Specifications Attribute 1762-L24AWA, 1762-L24AWAR 1762-L24BWA, 1762-L24BXB, 1762-L40BWA, 1762-L40BXB 1762-L40AWA, 1762-L40AWAR 1762-L24BWAR, 1762-L24BXBR, 1762-L40BWAR, 1762-L40BXBR Inputs 0 through 3 Inputs 4 and higher On-state Voltage Range 79…132V AC @ 47 Hz…63 Hz 14…26.4V DC @ 55 °C (131 °F) 10…26.4V DC @ 55 °C (131 °F) 14…30.0V DC @ 30 °C (86 °F) 10…30.0V DC @ 30 °C (86 °F) Off-state Voltage Range 0…20V AC 0…5V DC Operating Frequency N/A 0 Hz…20 kHz 0 Hz…1 kHz (scan time dependent) Signal Delay, max ON Delay = 20 ms Standard inputs: selectable from 0.5…16 ms OFF Delay = 20 ms high-speed inputs: selectable from 0.025…16 ms On-state Current: min 5.0 mA @ 79V AC 2.5 mA @ 14V DC 2.0 mA @ 10V DC nom 12 mA @ 120V AC 7.3 mA @ 24V DC 8.9 mA @ 24V DC max 16.0 mA @ 132V AC 12.0 mA @ 30V DC 12.0 mA @ 30V DC Off-state Leakage Current, max 2.5 mA, max 1.5 mA, min Impedance, nom 12 kΩ @ 50 Hz 3.3 kΩ 2.7 kΩ 10 kΩ @ 60 Hz Inrush Current, max 250 mA at 120V AC --- Publication 1761-SG001F-EN-P - March 2011 Input Power Required at 24Vdc (Watts) Input Power Required at 24Vdc (Watts) 60 Select MicroLogix 1200 Controllers MicroLogix 1200 Controller Digital Output Specifications Attribute 1762- L24AWA, L24BWA, L24BXB, L24BXB, L40BXB L40AWA, L40BWA, L40BXB, L24BXBR, L40BXBR L24AWAR, L24BWAR, L24BXBR, L40AWAR, L40BWAR, L40BXBR Relay FET Standard Operation FET High-speed Operation (Output 2 only) Operating Voltage Range 5…125V DC 21.6…27.6V DC 21.6…27.6V DC 5…264V AC Continuous Current per Point, max See MicroLogix 1500 Controller Relay See below, MicroLogix 1200 100 mA Contact Rating on page 72. Controller FET Standard Outputs Continuous Current per Point, max. Continuous Current per Common, max 8.0 A 7.5 A for L24BXB, L24BXBR 8.0 A for L40BXB, L40BXBR Continuous Current per Controller, max 30 A or total of per-point loads, whichever is less at 150V max 20 A or total of per-point loads, whichever is less at 240V max On-state Current, min 10.0 mA 1 mA 10.0 mA Off-state Leakage Current, max 0 mA 1 mA Signal Delay, max - resistive load ON Delay = 10 ms ON Delay = 0.1 ms ON Delay = 6 µs OFF Delay = 10 ms OFF Delay = 1.0 ms OFF Delay = 18 µs (1) Surge Current per Point (peak) --- 4 A for 10 ms (1) Repeatability is once every 2 seconds @ 55 °C (131 °F), once every 1 second @ 30 °C (86 °F). MicroLogix 1200 Controller Relay Contact Rating Voltage, max Amperes Amperes Continuous Voltamperes Make Break Make Break 240V AC 7.5 A 0.75 A 2.5 A 1800 VA 180 VA 120V AC 15 A 1.5 A (1) 125V DC 1.0 A 28 VA 0.22 A (1) 24V DC 2.0 A 1.2 A (1) For DC voltage applications, the make/break ampere rating for relay contacts can be determined by dividing 28 VA by the applied DC voltage. For example, 28 VA/48V DC = 0.58 A. For DC voltage applications less than 48V, the make/break ratings for relay contacts cannot exceed 2 A. For DC voltage applications greater than 48V, the make/break ratings for relay contact cannot exceed 1 A. MicroLogix 1200 Controller FET Standard Outputs Continuous Current per Point, max FET Current per Point FET Current per Common (1762-L24BXB, L40BXB, (1762-L40BXB and L40BXBR) 9.0 L24BXBR, L40BXBR) 2.0 8A, 30˚C (86˚F) 8.0 1.75 1.5A, 30˚C (86˚F) 7.0 1.5 6.0 1.25 5.5A, 55˚C (131˚F) 5.0 1.0 1.0A, 55˚C (131˚F) 4.0 Valid Range Valid Range 0.75 3.0 0.5 2.0 0.25 1.0 10˚C 30˚C 50˚C 70˚C (50˚F) (86˚F) (122˚F) (158˚F) 10˚C 30˚C 50˚C 70˚C (50˚F) (86˚F) (122˚F) (158˚F) Temperature Temperature Publication 1761-SG001F-EN-P - March 2011 Current (Amps) Current (Amps) Select MicroLogix 1200 Expansion I/O 61 MicroLogix 1200 Memory and Real-Time Clock Modules The controller is shipped with a memory module port cover in place. You can order the memory module, real-time clock, or combination module to suit your needs. Real-time Clock (1762-RTC) Allows for time/date scheduling Self-contained battery provides long-term time base Memory Module (1762-MM1) User program and data back-up Program compare Data file protection Memory module write protection Removal/insertion under power Combination Memory and Real-time Clock Module (1762-MM1RTC) Provides all real-time clock and memory back-up functions of the 1762-RTC and 1762-MM1 modules MicroLogix 1200 controllers expand by using the same 1762 I/O platform as MicroLogix 1100 Select MicroLogix 1200 controllers. The 1762 I/O expansion modules provide superior functionality in a small sized Expansion I/O low-cost package. A variety of modules complement and extend the capabilities of MicroLogix 1200 controllers by maximizing the flexibility of I/O count and type. The MicroLogix 1200 system design allows modules to be either DIN rail or panel mounted. Step 9 - Select: The DIN latches and screw mounting holes are an integral part of the package design. • I/O modules - digital, analog, and temperature Controller I/O can be expanded by using up to six expansion modules per controller • perform system expansion calculations (depending on power budget). • record your selections in the Selection Record (start on page 86) See Select MicroLogix 1100 Expansion I/O on page 50 for available modules and specifications. 1762 Expansion I/O Modules Connected to a MicroLogix 1200 Controller Publication 1761-SG001F-EN-P - March 2011 62 Perform MicroLogix 1200 Controller System Expansion Calculations A download is also available for system validation. On the Internet, go to Perform MicroLogix 1200 http://www.ab.com/micrologix. Controller System To have a valid system, both current and power requirements must be satisfied. Use the Expansion Calculations following worksheets to make your calculations. Follow these steps to verify the controller power supply loading. 1. Use the following table to select the components for your system. Do not exceed the MAXIMUM LIMIT for the number of I/O modules. 2. Fill in the current amounts and add up the TOTAL CALCULATED CURRENT. MicroLogix 1200 Controller Power Supply Loading - Calculate System Current Cat. No. Bus Current Draw Attribute Calculated Current for System at 5V DC (mA) at 24V DC (mA) at 5V DC (mA) at 24V DC (mA) (1)(2) (2) 0 1761-NET-AIC 120 (1)(2) (2) 0 1761-NET-ENI, 1761-NET-ENIW 100 (1)(2) (2) 0 2707-MVH232 or 2707-MVP232 80 Cat. No. n = Number of Modules A B n x A n x B (6 max) 1762-IA8 50 0 1762-IQ8 50 0 1762-IQ8OW6 110 80 1762-IQ16 (Series A) 60 0 1762-OA8 115 0 1762-OB8 115 0 1762-OB16 175 0 1762-OW8 80 90 1762-OW16 (Series A) 120 140 1762-OX6I 110 110 1762-IF2OF2 40 105 1762-IF4 40 50 1762-OF4 40 165 1762-IR4 40 50 1762-IT4 40 50 1762-OV32T 175 0 1762-OB32T 175 0 1762-IQ32T 170 0 1762-IQ16 (Series B) 70 0 1762-OW16 (Series B) 140 180 TOTAL MODULES: TOTAL CALCULATED CURRENT: (C) (D) For 1762-L24BWA, 1762-L40BWA, 1762-L24BWAR, and 1762-L40BWAR only, (E) add sum of any User 24V DC Sensor Current (1) These are optional accessories. Current is consumed only if the accessory is installed. (2) Current for the 1761-NET-AIC or 1761-NET-ENI(W) can be supplied by the controller’s communication port or from an external 24V DC source. No current is consumed from the controller when a user-suppled, external source is used. If an external source is to be used, do not select the device here. The current for a 2707-MVH232 or 2707-MVP232 MicroView Operator Interface is supplied from the controller’s communication port, if directly connected. Publication 1761-SG001F-EN-P - March 2011 Perform MicroLogix 1200 Controller System Expansion Calculations 63 3. Using the table below, verify that (C), (D), and (E) do not exceed the MAXIMUM LIMITS. If the MAXIMUM LIMIT is exceeded, you will need to adjust your selections. MicroLogix 1200 Controller Maximum Load Current Cat. No. Load Current 5V DC 24V DC User 24V DC Sensor Current 1762-L24AWA Calculated Value (C) (D) N/A 1762-L24AWAR MAXIMUM LIMIT 400 mA 350 mA 1762-L24BXB, 1762-L24BXBR 1762-L24BWA Calculated Value (C) (D) (E) 1762-L24BWAR MAXIMUM LIMIT 400 mA 350 mA 250 mA 1762-L40AWA Calculated Value (C) (D) N/A 1762-L40AWAR MAXIMUM LIMIT 600 mA 500 mA 1762-L40BXB, 1762-L40BXBR 1762-L40BWA Calculated Value (C) (D) (E) 1762-L40BWAR MAXIMUM LIMIT 600 mA 500 mA 400 mA 4. Use the table below to verify that the system is within the power loading limits of the controller. Fill in the (C), (D), and (E) values where indicated. Then calculate Watts and add up the Total Watts. Verify that Total Watts does not exceed the MAXIMUM POWER LIMIT. If the MAXIMUM POWER LIMIT is exceeded, you will need to adjust your selections. MicroLogix 1200 Controller Maximum Load Power Cat. No. 5V Power Consumption 24V Power Consumption Calculated Watts MAXIMUM Calculated Watts Calculated Watts (sum of 5V and 24V) POWER LIMIT 1762-L24AWA (C) x 5V = W (D) x 24V = W W 10.4 W 1762-L24AWAR 1762-L24BXB (C) x 5V = W (D) x 24V = W W 10.4 W 1762-L24BXBR 1762-L24BWA (C) x 5V = W (D)+(E) x 24V = W W 12 W 1762-L24BWAR 1762-L40AWA (C) x 5V = W (D) x 24V = W W 15 W 1762-L40AWAR 1762-L40BXB (C) x 5V = W (D) x 24V = W W 15 W 1762-L40BXBR 1762-L40BWA (C) x 5V = W (D)+(E) x 24V = W W 16 W 1762-L40BWAR Publication 1761-SG001F-EN-P - March 2011 64 Select MicroLogix 1400 Controllers MicroLogix 1400 Base Units Select MicroLogix 1400 Controllers The base unit houses embedded inputs, outputs, power supply, and communication ports. The base unit also provides the interface to expansion I/O when required by an application. Step 10 - Select: MicroLogix 1400 Controller Catalog Number Detail • controller - review power and I/O configurations to select a controller 1766 - L 32 B W A A catalog number; see power supply and I/O specification for more detailed information Bulletin Number Analog I/O • accessories - memory modules A = available • record your selection in the Selection Record (starts on page 86) Base Unit None = not available Number of I/O Power Supply A = 120/240V AC Input Type: B = 24V DC A = 120V AC Output Type: B = 24V DC W = Relay X = Relay/24V DC FET MicroLogix 1400 Controller Power and I/O Configuration Cat. No. Line Voltage Number of Inputs Number of Outputs Embedded Analog I/O 1766-L32BWA 120/240V AC (12) Fast 24V DC (12) Relay --- (8) Normal 24V DC 1766-L32AWA 120/240V AC (20) 120V AC (12) Relay --- 1766-L32BXB 24V DC (12) Fast 24V DC (6) Relay --- (8) Normal 24V DC (3) Fast 24V DC (3) Normal 24V DC 1766-L32BWAA 120/240V AC (12) Fast 24V DC (12) Relay (4) Voltage Inputs (8) Normal 24V DC (2) Voltage Outputs 1766-L32AWAA 120/240V AC (20) 120V AC (12) Relay (4) Voltage Inputs (2) Voltage Outputs 1766-L32BXBA 24V DC (12) Fast 24V DC (6) Relay (4) Voltage Inputs (8) Normal 24V DC (3) Fast 24V DC (2) Voltage (3) Normal 24V DC Outputs MicroLogix 1400 Controller Power Supply Specifications Attribute 1766-L32AWA, 1766-L32BWA, 1766-L32BXB, 1766-L32AWAA 1766-L32BWAA 1766-L32BXBA Power Supply Voltage 100...240V AC (-15%, 10%) at 47...63 Hz 24V DC (-15%, 10%) Class 2 SELV Publication 1761-SG001F-EN-P - March 2011 Select MicroLogix 1400 Controllers 65 MicroLogix 1400 Controller Power Supply Specifications Attribute 1766-L32AWA, 1766-L32BWA, 1766-L32BXB, 1766-L32AWAA 1766-L32BWAA 1766-L32BXBA Power Consumption 100 VA 120 VA 7.5...53 W Power Supply Inrush 120V AC: 25 A for 8 ms 24V DC: 15 A for 20 ms Current, max 240V AC: 40 A for 4 ms 24V DC Sensor Power --- 24V DC at 250 mA, 400µF --- capacitance, max MicroLogix 1400 Controller DC Input Power Requirements for 1766-L32BXB and 1766-L32BXBA Units 1766-L32BXBA Input Power versus 1762 Bus Load 60 50 40 30 20 10 0 515 25 35 1762 Bus Load (W) Publication 1761-SG001F-EN-P - March 2011 24V DC Power Supply Input Power (W) 66 Select MicroLogix 1400 Controllers MicroLogix 1400 Controller Digital Input Specifications Attribute 1766-L32AWA, 1766-L32BWA, 1766-L32BWAA, 1766-L32BXB, 1766-L32BXBA 1766-L32AWAA Inputs 0...11 (12 high-speed DC inputs) Inputs 12 and above (8 standard DC inputs) On-state Voltage Range 79...132V AC 4.5...24V DC 10...24V DC 4.5...26.4V DC at 60 °C (140 °F) 10...26.4V DC at 60 °C (140 °F) 4.5...30V DC at 30 °C (86 °F) 10...30V DC at 30 °C (86 °F) Off-state Voltage Range 0...20V AC 0...1.5V DC 0...5V DC Operating Frequency 47...63 Hz 0 Hz...100 kHz 0 Hz...1 kHz (scan time dependent) On-state Current min 5.0 mA @ 79 V AC 7.1 mA @ 4.5V DC 3.2 mA @ 10V DC nom 12 mA @ 120 V AC 9.9 mA @ 24V DC 5.3 mA @ 24V DC max 16.0 mA @ 132 V AC 10.5 mA @ 30V DC 5.5 mA @ 30V DC Off-state Leakage 2.5 mA, max 0.2 mA, max 1.5 mA, max Current, max Impedance, nom 12 kΩ at 50 Hz 2.4 kΩ 4.5 kΩ 10 kΩ at 60 Hz Inrush Current, max 250 mA MicroLogix 1400 Controller Analog Input Specifications Attribute Value Voltage Input Range 0...10.0V DC - 1 LSB Type of Data 12-bit unsigned integer Input Coding (0…10V DC) 0...4095 Voltage Impedance >199 kΩ Input Resolution 12 bit Non-linearity (in percent full scale) ±0.5% of full scale Overall Accuracy ±1.0% of full scale Update Time 100/20/16.67/4 ms (selectable) Voltage Input Overvoltage Protection 10.5 V DC Field Wiring to Logic Isolation Non-isolated with internal logic MicroLogix 1400 Controller Analog Output Specifications Attribute Value Voltage Output Range 0...10.0V DC - 1 LSB Type of Data 12-bit unsigned integer Step Response 2.5 ms @ 95% Output Coding (0...10V DC) 0...4095 Load Range Voltage Output >1 kΩ Output Resolution 12 bit Analog Output Setting Time 3 ms, max Overall Accuracy ±1.0% of full scale Electrical Isolation Non-isolated with internal logic Cable Length 30 m (98 ft) shielded cable Publication 1761-SG001F-EN-P - March 2011 Select MicroLogix 1400 Controllers 67 Specifications for MicroLogix 1400 Controller Outputs in Hazardous locations (Class 1, Division 2, Groups A, B, C, D) Relay and FET Outputs Attribute 1766-L32AWA, 1766-L32AWAA, 1766-L32BXB, 1766-L32BXBA 1766-L32BWA, 1766-L32BWAA Controlled Load, max 1440 VA 1080 VA Continuous Current, max Current per Channel and Group Common 2.5 A per channel 2.5 A per channel 8 A max channel 8...11 common Current per Controller @ 150V, max 28 A or total of per-point loads, whichever is less @ 240V, max 20 A or total of per-point loads, whichever is less Relay Outputs Attribute Value (1) Turn On Time/Turn Off Time 10 ms, max Load Current 10 mA (1) Scan time dependent. Relay Contact Rating Amperes Voltamperes Amperes Voltage, max Make Break Continuous Make Break 240V AC 7.5 A 0.75 A 2.5 A 1800 VA 180 VA 120V AC 15 A 1.5 A 250V DC 0.11 A 1.0 A 28 VA 125V DC 0.22 A 1.0 A 28 VA 1766-L32BXB, 1766-L32BXBA FET Outputs Attribute General Operation High-speed Operation (1) (outputs 2, 3, and 4 only) Power Supply Voltage (Class 2) 24V DC (-15%, +10%) On-state Voltage Drop at maximum load current 1V DC Not Applicable at maximum surge current 2.5V DC Not Applicable Current Rating per Point maximum load See chart 100 mA minimum load 1.0 mA 20 mA maximum leakage 1.0 mA 1.0 mA Publication 1761-SG001F-EN-P - March 2011 68 Select MicroLogix 1400 Controllers 1766-L32BXB, 1766-L32BXBA FET Outputs Attribute General Operation High-speed Operation (1) (outputs 2, 3, and 4 only) Surge Current per Point peak current 4.0 A Not Applicable maximum surge duration 10 ms Not Applicable maximum rate of repetition at 30 °C (86 °F) once every second Not Applicable maximum rate of repetition at 65 °C (149 °F) once every 2 seconds Not Applicable Turn-on Time, max 11 µs 28 ns Turn-off Time, max 89 µs 2.3 µs (1) Output 2, 3, and 4 are designed to provide increased functionality over the other FET outputs. Outputs 2, 3, and 4 may be used like the other FET transistor outputs, but in addition, within a limited current range, they may be operated at a higher speed. Outputs 2, 3, and 4 also provide a pulse train output (PTO) or pulse width modulation output (PWM) function. MicroLogix 1400 Controller FET Standard Outputs FET Current per Point FET Total Current (1766-L32BXB, 1766-L32BXBA) (1766-L32BXB, 1766-L32BXBA) 2.0 8.0 1.75 7.0 1.5 A, 30 °C (86 °F) 6.0 A, 30 °C (86 °F) 1.5 6.0 1.25 5.0 1.0 4.0 0.75 A, 60 °C (140 °F) 0.75 Valid Range 3.0 0.5 2.0 3.0 A, 60 °C (140 °F) Valid Range 0.25 1.0 10 °C 30 °C 50 °C 70 °C 80 °C 10 °C 30 °C 50 °C 70 °C 80 °C (50 °F) (86 °F) (122 °F) (158 °F) (176 °F) (50 °F) (86 °F) (122 °F) (158 °F) (176 °F) Temperature Temperature MicroLogix 1400 Memory Module (1766-MM1) The controller is shipped with a memory module port cover in place. You can order the memory module to provide removable backup of your User Program and User Data, or to transport your program between controllers. Memory modules allow: user programs and data to be store as backup. transport programs for use with other controllers. special safety/security features for pres s control and other critical applications. auto-recovery, through a power cycle, after a controller fault. comparison of programs. data file and memory module write protection. removal/insertion under power. Publication 1761-SG001F-EN-P - March 2011 Current (Amps) Current (Amps) Select MicroLogix 1400 Expansion I/O 69 MicroLogix 1400 controllers expand by using the same 1762 I/O platform as MicroLogix 1100 Select MicroLogix 1400 controllers. The 1762 I/O expansion modules provide superior functionality in a small sized Expansion I/O low-cost package. A variety of modules complement and extend the capabilities of MicroLogix 1400 controllers by maximizing the flexibility of I/O count and type. The MicroLogix 1400 system design allows modules to be either DIN rail or panel mounted. Step 11 - Select: The DIN latches and screw mounting holes are an integral part of the package design. • I/O modules - digital, analog, and temperature Controller I/O can be expanded by using up to seven expansion modules per controller. • record your selections in the Selection Record (start on page 86) See Select MicroLogix 1100 Expansion I/O on page 50 for available modules and specifications. 1762 Expansion I/O Modules Connected to a MicroLogix 1400 Controller Publication 1761-SG001F-EN-P - March 2011 70 Select MicroLogix 1500 Controllers MicroLogix 1500 Base Units Select MicroLogix 1500 Controllers The base unit houses embedded inputs, outputs, power supply, and the channel 0 communication port. The base unit also provides the interface to expansion I/O when required by an application. Step 12 - Select: MicroLogix 1500 Controller Catalog Number Detail • base unit - review power and I/O configurations to select a catalog number; see power supply and I/O 1764 - 24 A W A specifications for more detailed information • processor - see notes at Step 1 Bulletin Number Power Supply • accessories - data access tool; real-time A = 120/240V AC clock and memory modules • record your selections in the Selection Number of I/O B = 24V DC Record (start on page 86) Output Type: Input Type: W = Relay A = 120V AC X = Relay/24V DC FET B = 24V DC MicroLogix 1500 Controller Power and I/O Configuration Cat. No. Line Voltage Number of Inputs Number of Outputs High Speed I/O 1764-24AWA 120/240V AC (12) 120V AC (12) Relay, 2 isolated relays per unit N/A 1764-24BWA 120/240V AC (8) Standard 24V DC (12) Relay, 2 isolated relays per unit (4) 20 kHz input (4) Fast 24V DC 1764-28BXB 24V DC (8) Standard 24V DC (6) Relay, 2 isolated relays per unit (8) 20 kHz input (8) Fast 24V DC (4) Standard 24V DC FET (2) 20 kHz output (2) Fast 24V DC FET MicroLogix 1500 Base Unit Power Supply Specifications Attribute 1764-24AWA 1764-24BWA 1764-28BXB Power Supply Voltage 85…265V AC at 47…63 Hz 85…265V AC at 47…63 Hz 20.4…30V DC Power Consumption 70 VA 88 VA 30 W Power Supply Inrush Current, max 120V AC: 25 A for 8 ms 120V AC: 25 A for 8 ms 24V DC: 4 A for 150 ms 240V AC: 40 A for 4 ms 240V AC: 40 A for 4 ms (1) (2) 5V DC 2250 mA 2250 mA Load Current , max 2250 mA (2) 24V DC 400 mA 400 mA 400 mA Load Power, max 16 W 22 W 16 W (2) 24V DC Sensor Power N/A N/A 400 mA , 400 µF capacitance, max (1) See Perform MicroLogix 1500 System Expansion Calculations on page 78 for an example system validation worksheet to calculate expansion I/O power usage. (2) Do not allow the total load power consumed by the 5V DC, 24V DC, and sensor power outputs to exceed 22 W. Publication 1761-SG001F-EN-P - March 2011 Select MicroLogix 1500 Controllers 71 Choosing a Power Supply for the 1764-28BXB This figure contains information for selecting a power supply for applications using a 1764-28BXB base unit. Use the worksheets on page 78 to calculate the total power (Watts) consumed by the system. With that information, use the graphs below to choose a power supply. You can use either current or power, depending on how the power supply is rated. Input Current Required Input Power Required 1.4 30 1.2 25 1 20 0.8 15 0.6 10 0.4 5 0.2 0 0 0 2 4 6 8 101214 1618 0 2 4 6 8 10 12 14 16 18 Calculated Load Power (Watts) Calculated Load Power (Watts) MicroLogix 1500 Base Unit Input Specifications Attribute 1764-24AWA 1764-24BWA and 1764-28BXB Inputs 0...7 Inputs 8 and Higher On-state Voltage Range 79…132V AC at 47 Hz…63 Hz 14…30.0 V DC at 30 °C (86 °F) 10…30.0 V DC at 30 °C (86 °F) 14…26.4 V DC at 55 °C (131 °F) 10…26.4 V DC at 55 °C (131 °F) Off-state Voltage Range 0…20V AC 0 to 5V DC 0…5V DC Operating Frequency N/A 1 kHz…20 kHz 1 Hz…500 Hz Signal Delay ON Delay = 20 ms standard inputs: selectable from 0.5 to 16 ms OFF Delay = 20 ms high-speed inputs: selectable from 0.025 to 16 ms On-state Current min 5.0 mA at 79V AC 2.5 mA at 14V DC 2.0 mA at 10V DC nom 12.0 mA at 120V AC 7.3 mA at 24V DC 8.9 mA at 24V DC max 16.0 mA at 132V AC 12.0 mA at 30V DC 12.0 mA at 30V DC Off-state Leakage Current 2.5 mA, min 1.5 mA, min 1.5 mA, min Impedance, nom 12 kΩ at 50 hZ 3.3 kΩ 2.7 kΩ 10 kΩ at 60 Hz Inrush Current, max 250 mA at 120V AC N/A N/A Publication 1761-SG001F-EN-P - March 2011 Input Current Required at 24V DC Input Power Required (Watts) 72 Select MicroLogix 1500 Controllers MicroLogix 1500 Base Unit Output Specifications Attribute 1764-24AWA,1764 -24BWA, 1764-28BXB 1764-28BXB Relay FET Standard Operation FET High-speed Operation (Outputs 2 and 3 only) Operating Voltage Range 5…125V DC 20.4…26.4V DC 5…264V AC Continuous Current per Point, max See MicroLogix 1500 Controller Relay 1 A @ 55 °C (131 °F) 100 mA Contact Rating on page 72. 1.5 A @ 30 °C (86 °F) Continuous Current per Common, max 8.0 A 6.0 A Continuous Current per Controller, max 24 A @ 150V 18 A @ 150V 20 A @ 240V 18 A @ 240V On-state Current, min 5.0 mA @ 79V AC 2.5 mA @ 14V DC 2.0 mA at 10V DC Off-state Leakage Current, max 0 mA 1 mA Signal Delay, max - resistive load ON Delay = 10 ms ON Delay = 0.1 ms ON Delay = 6 µs OFF Delay = 10 ms OFF Delay = 1.0 ms OFF Delay = 18 µs (1) Surge Current per Point (peak) N/A 4 A for 10 ms (1) Repeatability is once every 2 seconds at 55 °C (131 °F), once every 1 second at 30 °C (86 °F). MicroLogix 1500 Controller Relay Contact Rating Voltage, max Amperes Amperes Voltamperes Continuous Make Break Make Break 240V AC 7.5 A 0.75 A 2.5 A 1800 VA 180 VA 120V AC 15 A 1.5 A (1) 125V DC 1.0 A 28 VA 0.22 A (1) 24V DC 2.0 A 1.2 A (1) For DC voltage applications, the make/break ampere rating for relay contacts can be determined by dividing 28 VA by the applied DC voltage. For example, 28 VA/48V DC = 0.58 A. For DC voltage applications less than 48V, the make/break ratings for relay contacts cannot exceed 2 A. For DC voltage applications greater than 48V, the make/break ratings for relay contact cannot exceed 1 A. MicroLogix 1500 Processors In the controller system, the processor unit provides logic processing, trim potentiometers, Run/Remote/Program mode switch, communication toggle push button and (using the 1764-LRP processor) an electrically isolated RS-232 port. The processor also provides the interface to the DAT, real-time clock, and memory modules. There are two processor units: 1764-LSP and 1764-LRP. Publication 1761-SG001F-EN-P - March 2011 Select MicroLogix 1500 Controllers 73 MicroLogix 1500 Data Access Tool (1764-DAT) The DAT plug-in tool provides an interface for on-the-fly data monitoring and adjustments. The DAT has five primary features: Direct access to 48 bit elements Direct access to 48 integer elements Two function keys Display of controller faults Removal and insertion under power MicroLogix 1500 Real-Time Clock and Memory Modules These optional modules attach to the processor unit. Both types of modules can be inserted or removed while the unit is under power. 1764 Real-Time Clock Modules Real-time clock modules establish a time-base for controller functions that need to be coordinated with real-time events. They provide year, month, day of month, day of week, hour, minute, and second information to the controller by using the RTC function file. 1764 Memory Modules Memory modules allow: user programs and data to be stored as backup. transport programs for use with other controllers. safety/security for press control and other critical applications. auto recovery, through a power cycle, after a controller fault. comparison of programs. data file and memory module write protection. MicroLogix 1500 Memory and Real-Time Clock Modules Cat. No. Description 1764-RTC MicroLogix 1500 Real-Time Clock Module 1764-MM1 MicroLogix 1500 8 KB Memory Module 1764-MM1RTC MicroLogix 1500 8 KB Memory Module with Real-Time Clock (1) MicroLogix 1500 16 KB Memory Module 1764-MM2 (1) MicroLogix 1500 16 KB Memory Module with Real-Time Clock 1764-MM2RTC (2) MicroLogix 1500 16 KB Memory Module 1764-MM3 (2) MicroLogix 1500 16 KB Memory Module with Real-Time Clock 1764-MM3RTC (1) Use with the 1764-LRP processor to support larger program and data requirements. (2) The 1764-MM3xxx modules have the same user memory as the 1764-MM2xxx modules except recipe data size. Recipe data which was stored to the Data Log Queue are in the MicroLogix 1500 LRP can be stored to the 1764-MM3xxx modules. There is no difference in functionality between the 1764-MM2xxx and 1764-MM3xxx modules except the 1764-MM3xxx modules can save recipe data from the Data Log Queue area. Publication 1761-SG001F-EN-P - March 2011 74 Select MicroLogix 1500 System Expansion Components To increase your I/O options, you can connect an additional bank of I/O to your MicroLogix Select MicroLogix 1500 1500 controller. An I/O bank is a group of I/O modules connected directly to one another. System Expansion Banks are separated by cables. Components In a MicroLogix 1500 system, a maximum of one 1769 Expansion cable can be used, allowing for two banks of I/O modules (one connected directly to the controller and the other connected via the cable). Each I/O bank requires its own power supply (Bank 0 uses the controller’s embedded power supply). Step 13 - Select: Only one power supply (embedded or expansion) can be used on an I/O bank. The expansion • I/O modules - digital, analog, temperature and high-speed counter power supply cannot be connected directly to a controller. It must be connected by using one • communication modules - DPI SCANport of the expansion cables. and DeviceNet • power supplies, cables and end caps Refer to the Compact I/O Selection Guide, publication 1769-SG002, to select the 1769 I/O • perform system expansion calculations modules and communication modules that you need. On the Internet, go to • record your selections in the Selection http://www.ab.com/micrologix and navigate to MicroLogix 1500 downloads. Record (start on page 86) Vertical Orientation Horizontal Orientation Expansion I/O Bank 0 (1) 1769-CRRx Expansion Cable Expansion 1769-CRLx(1) Expansion I/O Bank 0 Expansion Cable I/O Bank 1 1769-ECL Expansion I/O End Cap Bank 1 (1) The x in this catalog number can be either a 1 or a 3 representing the length of the cable: 1 = 1 ft (305 mm) and 3 = 3.28 ft (1 m). The following section of this document, 1769 Compact Expansion I/O and Communication Modules, provides information for choosing Compact I/O expansion options. Basically, you select the I/O options you need and then verify that the selections do not exceed the available power in the system. As shown above, the power can be provided from the Base Unit or an expansion power supply. After reviewing the I/O options, use the worksheets in the Perform MicroLogix 1500 System Expansion Calculations section on page 78 to list your I/O choices and determine the system power requirements. The worksheets will let you know if the system is within allowable limits. A download is also available for system validation. On the Internet, go to http://www.ab.com/micrologix and navigate to MicroLogix 1500 downloads. Publication 1761-SG001F-EN-P - March 2011 Select MicroLogix 1500 System Expansion Components 75 1769 Compact Expansion I/O and Communication Modules High-density Bulletin 1769 Compact I/O rackless expansion modules offer superior functionality and high value at a competitive price. With a variety of modules, they complement and extend the capabilities of the MicroLogix 1500 controller by maximizing flexibility of the I/O count and type. Up to 16 modules can be used in a MicroLogix 1500 system when using a series B Base Unit (up to 8 for series A) dependent on power requirements. In addition to staying within the power limits, the modules must be distributed within the system by using the following limitations: a maximum of 8 modules can be connected directly to the Base Unit a maximum of 8 modules can be connected to each side of the Expansion Power Supply The compact I/O system provides an excellent platform for future enhancements, so you can easily choose the level of control as your application needs grow. Advantages Modular system Feature-rich I/O to address a wide range of applications Rackless design reduces system components Small footprint shrinks panel space requirements Front insertion and removal reduces assembly and replacement time Unique tongue-and-groove interlocking case design in order to have a strong, mechanical connection between modules Software keying prevents incorrect module placement within a system Digital I/O modules available with AC /DC relay, 24V DC, and 120/240V AC voltages Analog I/O modules configurable for voltage or current Thermocouple, RTD, and High-speed Counter input modules DPI/SCANport Module provides connection to PowerFlex 7 Class drives, other DPI-based Host devices, and SCANport-based Host devices such as 1305 and 1336 PLUS II drives. DeviceNet adapter and scanner communication modules Publication 1761-SG001F-EN-P - March 2011 76 Select MicroLogix 1500 System Expansion Components 1769 Compact Power Supplies, Expansion Cables, and End Caps Power Supplies Using an expansion I/O power supply increases the system’s capacity for adding expansion I/O modules. 1769 Compact Power Supplies Specifications Attribute 1769-PA2 1769-PB2 1769-PA4 1769-PB4 Input Voltage, nom 120V AC or 240V AC 24V DC 120V AC or 240V AC 24V DC Input Voltage Range 85…265V AC 19.2…31.2V DC 85…265V AC 19.2…32V DC Line Requirement, max 100 VA @ 120V AC 50 VA @ 24V DC 200 VA @ 120V AC 100 VA @ 24V DC 130 VA @ 240V AC 240 VA @ 240V AC Output Bus Current Capacity 2 A @ 5V DC 4 A @ 5V DC (0°...55 °C) (32°...131 °F) 0.8 A @ 24V DC 2 A @ 24V DC 24V DC User Power Capacity 250 mA N/A N/A N/A (0°...55 °C) (32°...131 °F) Inrush, max 25 A at 132V AC, 10 Ω source 30 A at 31.2V DC 25 A at 132V AC, 10 Ω 30 A at 31.2V DC impedance source impedance 40 A at 265V AC, 10 Ω source 40 A at 265V AC, 10 Ω impedance source impedance Line Loss Ride Through 10 ms, min...10 s, max 5 ms, min,...10 s, max Load Current, min 0 mA at 5V DC; 0 mA at 24V DC Short Circuit Protection Front Access Fuse Front Access Fuse Front Access Fuse Front Access Fuse (replacement part number: (replacement part number: (replacement part number: (replacement part number: Wickmann 19195-3.15A, Wickmann 19193-6.3A) Wickmann 19195-3.15A or Wickmann 19193-6.3A) Wickmann 19343-1.6A, or Wickmann 19181-4A) Wickmann 19181-4A) Bus Overvoltage Protection for both +5V DC and for +24V DC Isolation Voltage 1836V AC for 1 s or 2596V DC 1200V AC for 1 s or 1697V 1836V AC for 1 s or 2596V 1200V AC for 1 s or 1697V (input power to 1769 bus) for 1 s DC for 1 s DC for 1 s DC for 1 s Verified by one of these or or or or dielectric tests 265V Working Voltage (IEC 75V Working Voltage (IEC 265V Working Voltage (IEC 75V Working Voltage (IEC Class 1 - grounding required) Class 1 - grounding Class 1 - grounding required) Class 1 - grounding required) required) Power Supply Distance Rating 8 (up to eight I/O modules can be connected on either side of the power supply for a maximum of 16 modules) Certifications UL 508, CSA (Class I, Division 2, Group A, B, C, D), CE Publication 1761-SG001F-EN-P - March 2011 Select MicroLogix 1500 System Expansion Components 77 Expansion Cables Expansion cables are required when adding a second bank of I/O modules. They are connected from the right side of the controller bank to either the left or right side of the expansion bank. 1769 Compact Expansion Cables Selection Chart Cable Type Length Cat. No. right bank-to-right bank 305 mm (1 ft) 1769-CRR1 right bank-to-right bank 1 m (3.28 ft) 1769-CRR3 right bank-to-left bank 305 mm (1 ft) 1769-CRL1 right bank-to-left bank 1 m (3.28 ft) 1769-CRL3 End Caps In every expansion I/O system, an end cap must be used to terminate the end of the serial communication bus. The end cap is connected to the last I/O module in the system. 1769 Compact End Caps Selection Chart End Cap Cat. No. right end cap 1769-ECR left end cap 1769-ECL Publication 1761-SG001F-EN-P - March 2011 78 Perform MicroLogix 1500 System Expansion Calculations A download is also available for system validation. On the Internet, go to Perform MicroLogix 1500 http://www.ab.com/micrologix and navigate to MicroLogix 1500. System Expansion The procedure in this publication consists of: Calculations Select System Devices Verifying the System Loading Selecting Expansion Cables and End Caps Select System Devices 1. Use the table below to select the processor and optional communication or display devices. Enter a 1 in the Select Devices column. 2. Enter the current draw values in the Calculated Current for System columns. If an external power supply will be used to power communication devices, do not include their current draw values in this calculation. Add up the current draw values to determine the SUBTOTAL1 values. Selecting Hardware: MicroLogix 1500 Base Unit and Communication/Display Devices Cat. No. Select Bus Current Draw Attribute Calculated Current for System Device(s) at 5V DC (mA) at 24V DC (mA) at 5V DC (mA) at 24V DC (mA) Choose a Processor, LSP or LRP: 1764-LSP 300 0 1764-LRP 380 0 (1) 350 0 1764-DAT optional Communication/Display Devices, optional, one only max: (1)(2) 0120 1761-NET-AIC 1761-NET-ENI, 0100 (1)(2) 1761-NET-ENIW 2707-MVH232, 080 (1)(2) 2707-MVP232 SUBTOTAL1 (A1) (B1) (1) These are optional accessories. Current is consumed only if the accessory is installed. (2) Current for the 1761-NET-AIC and 1761-NET-ENI(W) devices can be supplied by controller communication port or from an external 24V DC source. No current is consumed from the controller when a user-supplied, external source is used. If an external source is to be used, do not select the device here. The current for a 2707-MVH232 or 2707-MVP232 MicroView Operator Interface is supplied from the controller communication port, when directly connected. Publication 1761-SG001F-EN-P - March 2011 Perform MicroLogix 1500 System Expansion Calculations 79 3. Use the table on page 80 to select the I/O modules. Enter the number of modules in either the Base Unit Expansion or the Bank 1 column. When planning the system layout, keep in mind that each IMPORTANT module has a Power Supply Distance Rating. This is the maximum distance an I/O module can be located from the power supply. For most modules, the rating is 8. For the 1769-HSC and 1769-SDN, the rating is 4. For the 1769-SM1, the rating is 6 Depending on its configuration, the 1769-SDN can transfer large amounts of data into and out of the controller I/O image tables. Care should be taken when using more than three of these modules to verify that they are optimally configured. This will allow for the maximum available 4 KB data table size will not be exceeded. Refer to the 1769-SDN User Manual for more details. 4. Enter the current draw values in the Calculated Current columns. Add up the current draw values to determine the SUBTOTAL2 values. 5. Verify that the total number of modules does not exceed the system limits. Publication 1761-SG001F-EN-P - March 2011 80 Perform MicroLogix 1500 System Expansion Calculations Selecting Hardware: 1769 Compact Expansion I/O Select I/O Modules for Each Bank Bus Current Draw Calculate Current Draw Attribute (mA) Expansion I/O Base Unit Bank 1 Calculated Current for Calculated Current for Modules Expansion Base Unit Expansion (mA) Bank 1 Power Supply (mA) n1 n2 X Y n1 x X n1 x Y n2 x X n2 x Y (1) Cat. No. at 5V DC at 24V DC at 5V DC at 24V DC at 5V DC at 24V DC Number of Modules 1769-ASCII 500 0 1769-BOOLEAN 220 0 1769-IA16 115 0 1769-IA8I 90 0 1769-IF4 (series A) 120 150 1769-IF4 (series B) 120 60 1769-IF4I 145 125 1769-IF4XOF2 120 160 1769-IF4FX0F2F 220 120 1769-IF8 120 70 1769-IF16C 19070 1769-IF16V 190 70 1769-IG16 120 0 1769-IM12 100 0 1769-IQ16 115 0 1769-IQ16F 110 0 1769-IQ32 170 0 1769-IQ32T 170 0 1769-IQ6XOW4 105 50 1769-IR6 100 45 1769-IT6 100 40 1769-OA8 145 0 1769-OA16 225 0 1769-OB8 145 0 1769-OB16 200 0 1769-OB16P 160 0 1769-OB32 300 0 1769-OB32T 220 0 1769-OF2 (series A) 120 200 1769-OF2 (series B) 120 120 1769-OF4 120 170 1769-OF4CI 145 140 1769-OF4VI 145 75 1769-OF8C 145 160 1769-OF8V 145 125 1769-OG16 200 0 1769-OV16 200 0 1769-OV32T 200 0 1769-OW8 125 100 1769-OW8I 125 100 1769-OW16 205 180 Publication 1761-SG001F-EN-P - March 2011 Perform MicroLogix 1500 System Expansion Calculations 81 Selecting Hardware: 1769 Compact Expansion I/O Select I/O Modules for Each Bank Bus Current Draw Calculate Current Draw Attribute (mA) Expansion I/O Base Unit Bank 1 Calculated Current for Calculated Current for Modules Expansion Base Unit Expansion (mA) Bank 1 Power Supply (mA) n1 n2 X Y n1 x X n1 x Y n2 x X n2 x Y (1) Cat. No. at 5V DC at 24V DC at 5V DC at 24V DC at 5V DC at 24V DC Number of Modules (2) 425 0 1769-HSC (2) 440 0 1769-SDN (3) 280 0 1769-SM1 (2) 350 0 1769-SM2 TOTAL MODULES: SUBTOTAL2: (A2) (B2) (C) (D) (1) Up to 16 modules can be used in a MicroLogix 1500 system when using a series B Base Unit and series C processor (up to 8 for series A base units). A maximum of 8 modules can be connected directly to the Base Unit. A maximum of 8 modules can be connected to each side of the Expansion Power Supply. (2) The 1769-ASCII, 1769-HSC, 1769-SDN, and 1769-SM2 modules have a power supply distance rating of 4. They can have no more than 3 modules between them and the MicroLogix 1500 Base Unit or Expansion Power Supply. (3) The 1769-SM1 module has a power supply distance rating of 6. They can have no more than 5 modules between it and the MicroLogix 1500 Base Unit or Expansion Power Supply. Publication 1761-SG001F-EN-P - March 2011 82 Perform MicroLogix 1500 System Expansion Calculations Verifying the System Loading To have a valid system, both current and power requirements must be satisfied. Verify the Base Unit Loading 1. Enter the SUBTOTAL values from the tables on pages 78 and 80. 2. Add the total current draw for the Base Unit. 3. Verify the values are within the maximum limits. MicroLogix 1500 Base Unit Power Supply Loading - Verify the Current Limits Calculated Current for System Current from at 5V DC (mA) at 24V DC (mA) For the 1764-24BWA module only, enter sum of any User 24V DC Sensor Current (E) MAXIMUM LIMIT 400 mA User 24V DC Values from SUBTOTAL1 (A1) (B1) Values from SUBTOTAL2 (A2) (B2) TOTAL BASE UNIT CURRENT LOADING (F) (G) MAXIMUM LIMIT 2250 mA at 5V DC 400 mA at 24V DC 4. Using the table below, verify that the MAXIMUM POWER LIMIT is not exceeded. MicroLogix 1500 Base Unit Power Supply Loading - Verify the Required Power Cat. No. 1764-24AWA, 1764-28BXB 1764-24BWA 5V Power Calculation (F) x 5V = W (F) x 5V = W 24V Power Calculation (G) x 24V = W (G) x 24V = W (E) x 24V = W Add up Total Watts W W MAXIMUM POWER LIMIT 16 W 22 W Publication 1761-SG001F-EN-P - March 2011 Perform MicroLogix 1500 System Expansion Calculations 83 Verifying the Expansion Power Supply Loading Using the values from SUBTOTAL2, verify that the system loading and I/O distribution are within the limits shown below. Consider future expansion when selecting a power supply. Bank 1 Power Supply Loading - Verify the Current Limits Attribute Cat. No. Calculated Current for System 24V DC User Output Capacity at 5V DC (mA) at 24V DC (mA) Values from SUBTOTAL2 (on page 81): (C) (D) MAXIMUM CURRENT LIMIT 1769-PA2 2000 800 250 mA 1769-PA4 4000 2000 N/A 1769-PB2 2000 800 1769-PB4 4000 2000 I/O Distribution - Distribute I/O modules such 1769-PA2 2000 800 250 mA that the current consumed from either the left 1769-PA4 2000 1000 side or the right side of the power supply never exceeds the following values: 1769-PB2 2000 800 1769-PB4 2000 1000 Selecting Expansion Cables and End Caps Any system using Compact I/O components must have an end cap. If I/O Bank 1 is used, an expansion cable is also required. Use the information on page 77 to make your selection from the table below. Select End Cap and Expansion Cable Type of System Requirement Cat. No. Selected Base Unit with Compact I/O only right end cap 1769-ECR Base Unit with Compact I/O and Bank 1, horizontal orientation right-to-left expansion cable 1769-CRL1, 1769-CRL3 right end cap 1769-ECR Base Unit with Compact I/O and Bank 1, vertical orientation right-to-right expansion cable 1769-CRL1, 1769-CRL3 left end cap 1769-ECL Publication 1761-SG001F-EN-P - March 2011 84 Select Replacement Parts Select Replacement Parts Step 14 - Select: • replacement parts • record your selections in the Selection Record (start on page 86) MicroLogix 1000 Replacement Parts Description Cat. No. Terminal Cover Doors for 1761-L32AWA, -L32BWA, or -L32AAA (2 doors per package) 1761-RPL-T32X Replacement Terminal Block — 6-position DH-485 plug/connector used with the 1761-NET-AIC. 1746-RT30 Replacement Terminal Block — 5-position DeviceNet plug/connector used with the 1761-NET-DNI. 1761-RPL-RT00 MicroLogix 1100 Replacement Part Description Cat. No. Replacement Battery 1763-BA MicroLogix 1200 Replacement Parts Description Cat. No. Replacement Removable Terminal Block — (1) 25-pt double row, (1) 29-point double row for 1762-L40AWA and -L40BWA 1762-RPLRTB40 MicroLogix 1400 Replacement Parts Description Cat. No. Replacement Battery 1747-BA Replacement Removable Terminal Block — (1) 25-pt double row, (1) 29-point double row for all 1766-L32xxxx 1762-RPLRTB40 MicroLogix 1500 Replacement Parts Description Cat. No. Replacement Terminal Block — 17-pt for 1764-24AWA and 1764-24BWA inputs 1764-RPLTB1 Replacement Terminal Block — 21-pt for 1764-28BXB inputs and outputs for all base units 1764-RPLTB2 Replacement Battery 1747-BA Publication 1761-SG001F-EN-P - March 2011 Select Training Materials 85 Select Training Materials Step 15 - Select: • training and promotional products - starter paks, demo units and simulators • record your selections in the Selection Record (start on page 86) Training Materials for MicroLogix 1000, 1100, 1200, 1400, and 1500 Controllers Description Cat. No. (1) MicroLogix 1000 Integrated Demonstration Unit includes: 1761-L20BWA-5A controller; 1761-NET-AIC DH-485 Interface; 1796-MICROx 1761-NET-DNI DeviceNet Interface; quadrature encoder; 4 selector switches; 8 illuminated pushbuttons; 1 potentiometer; 1 analog meter (1) MicroLogix 1500 Integrated Demonstration Unit includes: 1764-28BXB base unit; 1764-LSP processor unit; 1769-IF4 Analog Input 1796-MICRO15x Module; 1769-OF2 Analog Output Module;1761-NET-AIC DH-485 Interface Module; 1761-NET-DNI DeviceNet Interface Module; (series B) quadrature encoder; 4 selector switches; 8 illuminated pushbuttons; 1 potentiometer; 1 analog meter; 1 frequency meter MicroLogix 1000 Input Simulator. For use with 1761-L16BWA MicroLogix 1000 Controller. 1761-SIM-B16 MicroLogix 1200 Input Simulator. For use with 1762-L24BWA and 1762-L24BXB controllers. 1796-SIM1200 MicroLogix 1500 Input Simulator. For use with 1764-24BWA and 1764-28BXB base units. 1796-SIM1500 (1) MicroLogix 1200/PanelView 300 Micro Integrated Demonstration Unit includes: 1762-L24BWA, 2711-M3A18L1, inductive 1796-PV300MICROx proximity switch, photo-electric sensor, programming cable. MicroLogix 1100 Input Simulator. DEMO-SIM1100 (1) MicroLogix 1400 Demonstration Unit. DEMO-ML1400x (1) Connected Components Demonstration Unit. DEMO-MICROSOLx (1) The x equals the power cord option. Contact your local Allen-Bradley distributor for more information. Publication 1761-SG001F-EN-P - March 2011 86 Fill in Your Selection Listing Fill in Your Selection Listing Step 16 - Select: • all catalog numbers required for your system specification Master List of Catalog Numbers Cat. No. Description Quantity Selected MicroLogix 1000 Controllers 1761-L10BWA MicroLogix 1000 10-Point AC Controller 1761-L10BWB MicroLogix 1000 10-Point DC Controller 1761-L10BXB MicroLogix 1000 10-Point DC Controller 1761-L16AWA MicroLogix 1000 16-Point AC Controller 1761-L16BBB MicroLogix 1000 16-Point DC Controller 1761-L16BWA MicroLogix 1000 16-Point AC Controller 1761-L16BWB MicroLogix 1000 16-Point DC Controller 1761-L16NWA MicroLogix 1000 16-Point AC Controller 1761-L16NWB MicroLogix 1000 16-Point DC Controller 1761-L20AWA-5A MicroLogix 1000 25-Point AC Controller with Analog 1761-L20BWA-5A MicroLogix 1000 25-Point AC Controller with Analog 1761-L20BWB-5A MicroLogix 1000 25-Point DC Controller with Analog 1761-L32AAA MicroLogix 1000 32-Point AC Controller 1761-L32AWA MicroLogix 1000 32-Point AC Controller 1761-L32BBB MicroLogix 1000 32-Point DC Controller 1761-L32BWA MicroLogix 1000 32-Point AC Controller 1761-L32BWB MicroLogix 1000 32-Point DC Controller MicroLogix 1100 Controllers and Accessories 1763-L16AWA MicroLogix 1100 16-Point AC Controller 1763-L16BWA MicroLogix 1100 16-Point AC Controller 1763-L16BBB MicroLogix 1100 16-Point DC Controller 1763-L16DWD MicroLogix 1100 16-Point DC Controller 1763-MM1 MicroLogix 1100 Memory Module MicroLogix 1200 Controllers and Accessories 1762-L24AWA MicroLogix 1200 24-Point AC Controller 1762-L24AWAR MicroLogix 1200 24-Point AC Controller with Programming/HMI Port 1762-L24BWA MicroLogix 1200 24-Point AC Controller 1762-L24BWAR MicroLogix 1200 24-Point AC Controller with Programming/HMI Port 1762-L24BXB MicroLogix 1200 24-Point DC Controller 1762-L24BXBR MicroLogix 1200 24-Point DC Controller with Programming/HMI Port 1762-L40AWA MicroLogix 1200 40-Point AC Controller 1762-L40AWAR MicroLogix 1200 40-Point AC Controller with Programming/HMI Port Publication 1761-SG001F-EN-P - March 2011 Fill in Your Selection Listing 87 Master List of Catalog Numbers Cat. No. Description Quantity Selected 1762-L40BWA MicroLogix 1200 40-Point AC Controller 1762-L40BWAR MicroLogix 1200 40-Point AC Controller with Programming/HMI Port 1762-L40BXB MicroLogix 1200 40-Point DC Controller 1762-L40BXBR MicroLogix 1200 40-Point DC Controller with Programming/HMI Port 1762-MM1 MicroLogix 1200 Memory Module 1762-MM1RTC MicroLogix 1200 Memory Module with Real-Time Clock 1762-RTC MicroLogix 1200 Real-Time Clock Module MicroLogix 1100/1200/1400 I/O 1762-IA8 8-Point 120V AC Input Module 1762-IF2OF2 Combination 2-Channel Input 2-Channel Output Voltage/Current Analog Module 1762-IF4 4-Channel Voltage/Current Analog Input Module 1762-IQ16 16-Point Sink/Source 24V DC Input Module 1762-IQ8 8-Point Sink/Source 24V DC Input Module 1762-IQ8OW6 8 Point Sink/Source 24V DC Input/6-Point AC/DC Relay Output Combination Module 1762-IR4 4-Channel RTD/Resistance Input Module 1762-IT4 4-Channel Thermocouple/mV Input Module 1762-OA8 8-Point 120/240V AC Triac Output Module 1762-OB16 16-Point Sourcing 24V DC Output Module 1762-OB8 8-Point Sourcing 24V DC Output Module 1762-OF4 4-Channel Voltage/Current Analog Output Module 1762-OW16 16-Point AC/DC Relay Output Module 1762-OW8 8-Point AC/DC Relay Output Module 1762-OX6I 6-Point Isolated AC/DC Relay Output Module 1762-OV32T Solid State 24V DC Sink Output Module 1762-OB32T Solid State 24V DC Source Output Module 1762-IQ32T DC Input Module MicroLogix 1400 Controllers and Accessories 1766-L32BWA MicroLogix 1400 32-point AC controller 1766-L32AWA MicroLogix 1400 32-point AC controller 1766-L32BXB MicroLogix 1400 32-point DC controller 1766-L32BWAA MicroLogix 1400 32-point AC controller with Analog 1766-L32AWAA MicroLogix 1400 32-point AC controller with Analog 1766-L32BXBA MicroLogix 1400 32-point DC controller with Analog 1766-MM1 MicroLogix 1400 Memory Module MicroLogix 1500 Controllers and Accessories 1764-24AWA MicroLogix 1500 24-Point AC Base Unit 1764-24BWA MicroLogix 1500 24-Point AC Base Unit 1764-28BXB MicroLogix 1500 28-Point DC Base Unit 1764-DAT MicroLogix Data Access Tool 1764-LRP MicroLogix 1500 Processor Unit with RS-232 Port 1764-LSP MicroLogix 1500 Processor Unit 1764-MM1 MicroLogix 1500 8 KB Memory Module 1764-MM1RTC MicroLogix 1500 8 KB Memory Module with Real-Time Clock 1764-MM2 MicroLogix 1500 16 KB Memory Module Publication 1761-SG001F-EN-P - March 2011 88 Fill in Your Selection Listing Master List of Catalog Numbers Cat. No. Description Quantity Selected 1764-MM2RTC MicroLogix 1500 16 KB Memory Module with Real-Time Clock 1764-M3 MicroLogix 1500 16 KB Memory Module 1764-MM3RTC MicroLogix 1500 16 KB Memory Module with Real-Time Clock 1764-RTC MicroLogix 1500 Real-Time Clock Module 1769 Compact I/O Components 1769-ADN CompactLogix DeviceNet Adapter, series B 1769-ASCII Compact 2-channel ASCII Interface Module 1769-BOOLEAN Compact 24V I/O Boolean Control Module (1) 1769-CRL1 Compact I/O Right Bank-to-Left Bank 1-Foot Expansion Cable (1) 1769-CRL3 Compact I/O Right Bank-to-Left Bank 3-Foot Expansion Cable (1) 1769-CRR1 Compact I/O Right Bank-to-Right Bank 1-Foot Expansion Cable (1) 1769-CRR3 Compact I/O Right Bank-to-Right Bank 3-Foot Expansion Cable 1769-ECL Compact I/O Left End Cap 1769-ECR Compact I/O Right End Cap 1769-HSC Compact I/O High Speed Counter Module 1769-IA16 Compact 120V AC Input Module 1769-IA8I Compact Individually Isolated 120V AC Input Module 1769-IF4 Compact 1769-IF4 (series B or Later) Analog Input Module 1769-IF4I Compact 4-channel Isolated Analog Input Module 1769-IF4XOF2 Compact 8-Bit Low Resolution Analog I/O Combination Module 1769-IF4FXOF2F Compact Combination Fast Analog I/O Module 1769-IF8 Compact 8-channel Analog Input Module 1769-IF16C Compact High Density Analog Current Input Module 1769-IF16V Compact High Density Analog Voltage Input Module 1769-IG16 Compact TTL Input Module 1769-IM12 Compact 240V AC Input Module 1769-IQ16 CompactLogix 24V DC 16-point Sink/Source Input Module 1769-IQ16F CompactLogix 24V DC 16-point High Speed Sink/Source Input Module 1769-IQ32 CompactLogix 24V DC 32-point Sink/Source Input Module 1769-IQ32T Compact Current Sinking/Sourcing 24V DC Input Module 1769-IQ6XOW4 Compact Combination 24V DC Sink/Source Input & AC/DC Relay Output Module 1769-IR6 Compact I/O 1769-IR6 RTD/resistance Input Module 1769-IT6 Compact I/O 1769-IT6 Thermocouple/mV Input Module 1769-OA16 Compact 100 to 240V AC Solid State Output Module 1769-OA8 Compact 100 to 240V AC Solid State Output Module 1769-OB16 Compact Solid State 16-point 24V DC Source Output Module 1769-OB16P Compact Solid State 16-point 24V DC Source Output Module with Electronic Protection 1769-OB32 Compact Solid State 32-point 24V DC Source Output Module 1769-OB32T Compact Current Solid-state Sourcing 24V DC Output Module 1769-OB8 Compact Solid State 8-point 24V DC Source Output Module 1769-OF2 Compact Analog Output Module 1769-OF4 Compact Analog Output Module 1769-OF4CI Compact 4-channel Current Isolated Analog Output Module Publication 1761-SG001F-EN-P - March 2011 Fill in Your Selection Listing 89 Master List of Catalog Numbers Cat. No. Description Quantity Selected 1769-OF4VI Compact 4-channel Voltage Isolated Analog Output Module 1769-OF8C Compact 8-point Analog Current Output Module 1769-OF8V Compact 8-point Analog Voltage Output Module 1769-OG16 Compact TTL Output Module 1769-OV16 Compact Solid State 16-point 24V DC Sink Output Module 1769-OV32T Compact Current Sinking 24V DC Output Module 1769-OW16 Compact 16-Output AC/DC Relay Module 1769-OW8 Compact 8-Output AC/DC Relay Module 1769-OW8I Compact Individually Isolated 8-Output AC/DC Relay Module 1769-PA2 Compact 124/240V AC Expansion Power Supply 1769-PA4 Compact 124/240V AC Expansion Power Supply 1769-PB2 Compact 24V DC Expansion Power Supply 1769-PB4 Compact 24V DC Expansion Power Supply 1769-SDN CompactLogix DeviceNet Scanner Module 1769-SM1 Compact I/O to DPI/SCANport Module 1769-SM2 Compact I/O to DSI Communication Module MicroLogix Communication Interface Devices 1761-NET-AIC MicroLogix Advanced Interface Converter Module 1761-NET-DNI MicroLogix DeviceNet Interface Module 1761-NET-ENI MicroLogix Ethernet/IP Interface Module 1761-NET-ENIW MicroLogix Ethernet/IP Interface Module with Web Server Functionality Programming Tools and Software 1747-UIC Universal Serial Bus (USB) to DH-485 Interface Converter 1761-HHM-K08 8 KB Memory Module for MicroLogix 1000 Hand-Held Programmer 1761-HHM-K64 64 KB Memory Module for MicroLogix 1000 Hand-Held Programmer 1761-HHP-B30 MicroLogix 1000 Hand-Held Programmer 9324-RL0100ENE RSLogix 500 Starter 9324-RL0300ENE RSLogix 500 Programming for the SLC 500 and MicroLogix Families 9324-RL0700NXENE RSLogix 500 Professional 9324-RLM0100ENE RSLogix Micro Starter 9324-RLM0800ENE RSLogix Micro Professional Cables 1747-CP3 SLC 5/03, SLC 5/04, and SLC 5/05 RS-232 Programmer Cable 1761-CBL-AC00 RS-232 Operating Cable, 9-Pin D Shell to 9-Pin D Shell (MicroLogix), 0.5 m (1.5 ft) 1761-CBL-AM00 RS-232 Operating Cable, 8-Pin Mini DIN to 8-Pin Mini DIN (MicroLogix), 0.5 m (1.5 ft) 1761-CBL-AP00 RS-232 Operating Cable, 8-Pin Mini DIN to 9-Pin D Shell (MicroLogix), 0.5 m (1.5 ft) 1761-CBL-AS03 Controller/DH-485 Cable, 6-Pin Phoenix to RJ45, 3 m (10 ft) 1761-CBL-AS09 Controller/DH-485 Cable, 6-Pin Phoenix to RJ45, 9.5 m (31 ft) 1761-CBL-HM02 RS-232 Operating/Programming Cable, 8-Pin Mini DIN to 8-Pin Mini DIN (MicroLogix), 2 m (6.5 ft) 1761-CBL-PM02 RS-232 Operating/Programming Cable, 8-Pin Mini DIN to 9-Pin D Shell (MicroLogix), 2 m (6.5 ft) 1763-NC01 DH-485 cable, 8-Pin Mini DIN to 6-Pin Phoenix 2711-CBL-HM05 RS-232 Operating Cable, 8-Pin Mini DIN to 8-Pin Mini DIN (PanelView 300 Micro to MicroLogix), 5 m (16.4 ft) Publication 1761-SG001F-EN-P - March 2011 90 For More Information Master List of Catalog Numbers Cat. No. Description Quantity Selected 2711-CBL-HM10 RS-232 Operating Cable, 8-Pin Mini DIN to 8-Pin Mini DIN (PanelView 300 Micro to MicroLogix), 10 m (32.7 ft) 2711-CBL-PM05 RS-232 Operating/Programming Cable, 9-Pin D Shell to 8-Pin Mini DIN (PanelView 300 Micro to SLC or PLC), 5 m (16.4 ft) 2711-CBL-PM10 RS-232 Operating/Programming Cable, 9-Pin D Shell to 8-Pin Mini DIN (PanelView 300 Micro to SLC or PLC), 10 m (32.7 ft) Replacement Parts 1747-BA Lithium Battery (For RAM Memory Retention) for MicroLogix 1400/1500 controllers 1761-RPL-RT00 Replacement Terminal Block for 1761-NET-DNI, 5-position DeviceNet plug/connector 1761-RPL-T32X Terminal Cover Doors for 1761-L32AWA, 1761-L32BWA, 1761-L32AAA, 1761-L32BWB, or 1761-L32BBB (2 doors per package) 1761-RT30 Replacement Terminal Block for 1761-NET-AIC, 6-position DH-485 plug/connector 1762-RPLRTB40 Replacement Terminal Block for all 1762-L40xxxx and all 1766-L32xxxx Controllers 1763-BA Lithium Battery for MicroLogix 1100 controllers 1764-RPLTB2 21-Point Replacement Terminal Block for 1764-28BXB MicroLogix 1500 Base Unit (1) Approximate cable length is measured from end-to-end of the cable only. Visit the MicroLogix website at http://www.ab.com/micrologix to learn more about For More Information MicroLogix products and download MicroLogix software utilities and firmware updates. Software utilities are available for configuring the DNI and ENI network interface devices. System validation worksheets are available to determine I/O power usage. You can view or download publications at http://literature.rockwellautomation.com. To order paper copies of technical documentation, contact your local Rockwell Automation distributor or sales representative. Publication 1761-SG001F-EN-P - March 2011 For More Information 91 Notes: Publication 1761-SG001F-EN-P - March 2011 Rockwell Automation Support Rockwell Automation provides technical information on the Web to assist you in using its products. At http://www.rockwellautomation.com/support/, you can find technical manuals, a knowledge base of FAQs, technical and application notes, sample code and links to software service packs, and a MySupport feature that you can customize to make the best use of these tools. For an additional level of technical phone support for installation, configuration, and troubleshooting, we offer TechConnect support programs. For more information, contact your local distributor or Rockwell Automation representative, or visit http://www.rockwellautomation.com/support/. Installation Assistance If you experience a problem within the first 24 hours of installation, review the information that is contained in this manual. You can contact Customer Support for initial help in getting your product up and running. United States or Canada 1.440.646.3434 Outside United States or Use the Worldwide Locator at http://www.rockwellautomation.com/support/americas/phone_en.html, or contact Canada your local Rockwell Automation representative. New Product Satisfaction Return Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility. However, if your product is not functioning and needs to be returned, follow these procedures. United States Contact your distributor. You must provide a Customer Support case number (call the phone number above to obtain one) to your distributor to complete the return process. Outside United States Please contact your local Rockwell Automation representative for the return procedure. Documentation Feedback Your comments will help us serve your documentation needs better. If you have any suggestions on how to improve this document, complete this form, publication RA-DU002, available at http://www.rockwellautomation.com/literature/. Allen-Bradley, MicroLogix, SLC, SLC 5/03, SLC 500, CompactLogix, ControlLogix, FlexLogix, PowerFlex, PanelView, RSLogix, RSLogix 500, RSNetWorx for ControlNet, RSNetWorx for DeviceNet, Rockwell Automation, and Rockwell Software are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies. Rockwell Otomasyon Ticaret A.Ş., Kar Plaza İş Merkezi E Blok Kat:6 34752 İçerenköy, İstanbul, Tel: +90 (216) 5698400 Publication 1761-SG001F-EN-P - March 2011 92 Copyright © 2011 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.

Frequently asked questions

What makes Elite.Parts unique?

chervon down
At GID Industrial (Elite.Parts' parent company), we specialize in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

What kind of warranty will the 1762-IF4 have?

chervon down
Warranties differ by part and by which suppliers we use to procure it for you. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carriers does Elite.Parts work with?

chervon down
Elite.Parts can ship via FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Will Elite.Parts sell to me even though I live outside the USA?

chervon down
Absolutely! We are happy to serve customers regardless of location. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

I have a preferred payment method. Will Elite.Parts accept it?

chervon down
All major credit cards are accepted: Visa, MasterCard, Discover, and American Express. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

Allen Bradley 1747-M13 PLC Memory Module - Allen Bradley 1747-M13 64 K, Flash EPROM Memory Module fo...

product

Allen Bradley 1747-PSD Program Storage Device for SLC 5/03 and higher, MicroLogix 1000, 1100, 1200, ...

product

ALLEN BRADLEY 1756-IF6I I/O Module - ISOLATED ANALOG INPUT-CURRENT/VOLTAGE 6 PTS(20PIN)

product

ALLEN BRADLEY 1756-OB8I I/O Module - 10-30 VDC 2 AMP ISOLATED OUTPUT 8PTS (36 PIN)

product

ALLEN BRADLEY 1760-IB12XOW6I Pico Expansion I/O Module - PICO CONTROL RELAY, EXPANSION RELAY OUTPUT

product

ALLEN BRADLEY 1760-L12DWD-ND Controller - 12 I/O PICO CONTROLLER W/O DISPLAY, 12V DC