ALLEN BRADLEY 1400-DCU
Specifications
Energy Class
Class 2 Energy Limited
Humidity
5 to 95 percent, non–condensing
Isolation
500 Volts RMS
Operating Temp.
0° C to 50° C (32° F to 122° F) ambient air temperature range
Remote I/O Baud Rate
57.6kBaud, 115kBaud, 230kBaud
RS-232/RS-485 Baud Rate
300 to 19,200 Baud
Storage Temp.
–30°C to + 70°C (–22°F to 158°F)
Terminal Strip
Torque 5 lb-in (0.56 Nm) Torque
Datasheet
Extracted Text
ALLEN-BRADLEY A–B Bulletin 1400 Power Monitoring Products Bulletin 1400-DCU/BCU Communications Card Instruction Sheet Bulletin 1400–BCU Bulletin 1400–DCU Description The Bulletin 1400-DCU/BCU Communications Card supports Remote I/O and can be optionally configured as either RS-485 or RS-232C. Remote I/O and one of the two open architectures are active at all times. RS-232C or RS-485 are selected by means of a jumper. Note: Bulletin 1400–DCU is used with the Powermonitor Display Module and Bulletin 1400–BCU is used with the Powermonitor Block Module. Field Retrofit and This section explains the procedure for installing a universal communications card or changing the communications mode. Configuration of the Communications Card The card has a jumper block to allow the user to select RS-232C or RS-485 mode. The card’s currently selected communications mode may be viewed from the front panel of the Powermonitor Display Module, if the unit is operating, (see Publication 1400-5.2, Chapter 3, “Field Programming”), or by removing the card and examining the position of the jumper block. Instruction Sheet Bulletin 1400 Power Monitoring Products Removing An Existing Card ATTENTION: An anti–static wrist grounding strap must be worn at all times while performing any reconfigurations or ! modifications to the Powermonitor Display/Block Module. Failing to do so may permanently damage the static–sensitive components inside the Powermonitor Display/Block Module. 1. Turn off all power to the Powermonitor Display/Block Module. ATTENTION: Voltages may still be present when supply power is turned off to the unit. The unit will generally be powered by ! one source and will be monitoring another source. Turn off or disconnect all voltages applied to the unit. Failure to do so may result in personal injury or death. 2. Remove the four machine screws holding the rectangular communications card mounting plate on back of the Powermonitor Display/Block Module. case. 3. Carefully pull the plate away from the main chassis using the pull tabs to remove the card. Configuring the Display The circuit board of the communications card has a jumper labelled Jl. This jumper has two positions, which determine the communications mode. Communications Card Figure 1 illustrates the jumper in the bottom position for RS-485 mode. If the RS-232C mode is desired, move the jumper into the top position. Figure 1 Communications Card Jumper Configuration RS–232C Mode RS–485 Mode (Top Position) (Bottom Position) Configuring the Block The Powermonitor Block Communications card has a jumper labelled J1. This jumper has two positions, which determine the communications mode. Communications Card The jumper is configured for RS–485 mode from the factory. If RS–232C mode is desired, move the jumper over the two pins closest to the LEDs. Remote I/O Addressing The Powermonitor Block Communications card uses two DIP switches to configure the RIO address, starting quarter, data rate, and last rack. The DIP switches are shown in the default factory configuration. 2 Instruction Sheet Bulletin 1400 Power Monitoring Products Use the following table to change the default configuration. 8 7 6 5 4 3 2 1 SW1 not used set=1 RIO rack address 0–63 (00–77 octal) (1 = On) 8 7 6 5 4 3 2 1 not last last rack data rate group number SW2 used rack 6 5 4 3 2 1 set=1 0=no 0 0=hold 0 0=57.6kBaud 0 0=group 0 (1 = On) 1=yes 0 1=low 0 1=115kBaud 0 1=group 2 1 0=high 1 0=230kBaud 1 0=group 4 1 1=hold 1 1=230kBaud 1 1=group 6 Figure 2 Communications Card Jumper and Switch Locations RS 232 RS 485 SW2 J1 ON SW1 ON Reinstalling (or Field 1. Make sure that all power to the Powermonitor Display/Block Module is off. Retrofitting) the Communications Card ATTENTION: Voltages may still be present when supply power is turned off to the unit. The unit will generally be powered by ! one source and monitoring another source. Turn off or disconnect all voltages applied to the unit. Failure to do so may result in personal injury or death. 2. If field retrofitting a Powermonitor Display/Block Module, first remove the communications port cover plate on the rear cover of the Powermonitor Display/Block Module. 3 12 34 56 7 8 12 34 56 7 8 Instruction Sheet Bulletin 1400 Power Monitoring Products Reinstalling (or Field 3. Install the new card as follows: Retrofitting) the a.. Insert the communications card into the communications port Communications Card insuring that the communications card is oriented such that it will (continued) mate properly with the edge connector on the main board inside the Powermonitor Display/Block case. Important: The card is polarized to ensure installation in the correct orientation. b.. Align the holes in the mounting plate of the card with the mounting holes in the Powermonitor Module rear cover while lowering the card towards its seating. The installer will be able to feel when the card has found the correct alignment with the edge connector. c.. Once the board is resting in proper alignment on the edge connector, carefully press down to plug the card into the edge connector. d.. Install the four mounting screws through the mounting plate to secure the card in position. e.. Make all necessary communications connections to the communications card. Communications connection information can be found in Chapter 2 of Publication 1400–5.2, “Bulletin 1400 Power Monitor Installation and Operation” manual. f.. The card is now ready for use. INPUT & OUTPUT RATINGS Specifications Torque 5 lb-in (0.56 Nm) Torque Te Termin inal l S St triip 2 Maximum Wire 14 AWG, 2.5 mm , 75° C CU Wire Only Operating Temp. 0° C to 50° C (32° F to 122° F) ambient air temperature range Storage Temp. –30°C to + 70°C (–22°F to 158°F) Humidity 5 to 95 percent, non–condensing Isolation 500 Volts RMS RS-232/RS-485 300 to 19,200 Baud Baud Rate Remote I/O 57.6kBaud, 115kBaud, 230kBaud Baud Rate Energy Class Class 2 Energy Limited ALLEN-BRADLEY A ROCKWELL INTERNATIONAL COMPANY 40055–100–01(C) Publication 4 1400–5.0 – June 1995 1995 Allen-Bradley Company, Inc. Supersedes Publication 1400-5.0 – February 1994 PRINTED IN USA
Frequently asked questions
What makes Elite.Parts unique?
What kind of warranty will the 1400-DCU have?
Which carriers does Elite.Parts work with?
Will Elite.Parts sell to me even though I live outside the USA?
I have a preferred payment method. Will Elite.Parts accept it?
Why buy from GID?
Quality
We are industry veterans who take pride in our work
Protection
Avoid the dangers of risky trading in the gray market
Access
Our network of suppliers is ready and at your disposal
Savings
Maintain legacy systems to prevent costly downtime
Speed
Time is of the essence, and we are respectful of yours
Manufacturers








What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods