AGILENT / HP N6709A

Image of AGILENT / HP N6709A

Description

Agilent Technologies N6709A - Low-Profile MPS Mainframe Rack Mount Kit

Part Number

N6709A

Price

Request Quote

Manufacturer

AGILENT / HP

Lead Time

Request Quote

Category

DC POWER SUPPLIES

Specifications

Type

Rack Mount Kit

Features

Datasheet

pdf file

N6709A-d-415724416s.pdf

430 KiB

Extracted Text

Agilent N6700 MPS Low-Profile Modular Power System Models: N6700B, N6701A, N6702A, N6710B, N6711A, N6712A, N6731B-36B, N6741B-46B, N6751-54A, N6761A-62A, N6773A-76A, N6781A-82A Technical Overview New N6780 Series 2-quadrant source/measure units (SMUs) offer productivity gains and insights into power consumption never seen before. For details, visit www.agilent.com/find/N6700 • Ideal for ATE systems in R&D, design validation, and manufacturing • Small size: up to 4 outputs in 1U of rack space • Flexible, modular system: Can mix and match power levels and performance levels to optimize investment • Performance modules for critical test requirements • Value modules for basic DC power requirements • Fast command processing times to improve throughput • Connect via GPIB, LAN, or USB • Fully compliant to LXI Class C specification For Power Solutions in R&D – See back cover Small Size and N6700 System Features Flexibility for ATE Power supplies are a fundamental component of every test system in industries including aerospace and defense, consumer electronics, computers and peripherals, commu- nications, semiconductor and auto- motive electronics. Today’s complex automatic test equipment (ATE) sys- tems often require multiple power sources. Test system designers are challenged to keep costs down by Figure 1. Connectivity: GPIB, 10/100 Base-T Ethernet, and USB 2.0 all standard reducing rack space occupied by these multiple power supplies and to continually increase test system DC power system optimized to Built-in measurement throughput. meet specific test requirements. of voltage and current Test system engineers can invest The N6700 modules come standard The Agilent N6700 Low-Profile in high-performance outputs where with built-in measurement of volt- Modular Power System (MPS) is a speed and accuracy are needed, or age and current to simplify wiring 1U (rack unit) high, multiple-output purchase basic performance outputs and design of an ATE system. programmable DC power supply for simple DC power requirements. system that enables test system integrators to optimize performance, Small size power and price to match test needs. The Agilent N6700 MPS uses an advanced switching power supply The Agilent N6700 MPS gives test design that fits within 1U of rack system designers the flexibility to space. It has side air vents (no mix and match from over 20 different top or bottom air vents) so other DC power modules to create a 1- to instruments can be mounted 4-channel directly above or below it. (Requires rack mount kit; see Ordering Information.) 2 Protection features Each N6700 module is protected Output on against over-voltage, over-current, and over-temperature. A fault condition in one module can be V1 detected within 10 microseconds by other modules so that they can be quickly shut down to avoid Module 1 hazardous conditions on your V2 device under test (DUT). Delay 2 Connectivity V3 Module 2 The N6700 MPS comes standard with GPIB, USB 2.0, and 10/100 Base-T Ethernet LAN interfaces. Module 3 While GPIB is best suited for use Delay 3 with existing systems, Agilent offers USB and LAN to allow you to take advantage of the availability, speed, and ease-of-use of common Figure 2. Output sequencing computer industry standard inter- faces. The N6700 is fully compliant with the LXI Class C specification. Control from any browser For applications that require more The N6700 can be controlled via a than four DC power modules to be Security standard web browser. The N6700 sequenced, this output sequencing When used in systems running contains a web server that provides can be extended across multiple GPIB, the LAN and/or USB inter- web pages for monitor, control, and N6700 mainframes. By wiring together faces can be disabled for extra setup of the MPS. the I/O ports on the rear panel of security. Also, all non-volatile RAM the mainframes, a pair of synchro- data and settings can be cleared Output sequencing nization signals are sent between from the front panel. Each DC power module can be indi- mainframes, allowing the output vidually set to turn on or to turn off sequences of each mainframe to with a delay. By adjusting the delay be synchronized. This capability is times and then commanding the supported on N6700B, N6701A and N6700 to turn on, you can set the N6702A mainframes. It is not sup- N6700 modules to sequence on in a ported on N6700A mainframes. particular order. The same sequenc- ing capability is available to shut down the modules in a particular order. 33 Programmable voltage slew Easy parallel operation with the sum of the power modules For some applications, like inrush virtual channels installed in a mainframe exceeds limiting or powering rate-sensitive To increase available output power the total power available from the devices, it is necessary to slow and current, identical outputs can mainframe. In this case, the new down and control the speed of the be operated in parallel. To simplify power management features of the power supply to maintain a specific parallel operation for applications N6700 allow you to allocate main- voltage slew rate. The N6700 pro- requiring currents greater than frame power to the outputs where vides programmable voltage slew any single output can provide, the it’s needed, achieving maximum rate, so that you can easily control N6700 offers virtual channels, a asset utilization and flexibility. This the speed at which the output firmware-based feature that allows feature provides the safety from slews from one voltage to another. the N6700 system to treat up to unexpected and dangerous shut- You can set the speed of a voltage 4 channels as a single, synchro- downs that can occur with power change anywhere from its maxi- nized channel. Once configured, all systems without power management mum up/down programming speed functions (sourcing, measurements, when operated in a similar way. to its slowest change of up to 10 triggering, protection, and status seconds. Programmable voltage monitoring) behave as if there is For example, if your DUT requires slew is available from the front 1 channel of up to 4 times the 280 W on its main input, and 10 W panel when operating the N6700 capacity of a single channel, with- each on three auxiliary inputs, you manually or via computer control. out writing a single line of code to can configure a system consisting manage the interaction and syn- of one 300 W DC module and three Series operation chronization of the paralleled power 100 W DC modules. Even though To increase available voltage and supplies. the sum of the module power is power, similarly rated outputs can 600 W, you can still use the be operated directly in series. Virtual channel capability is avail- N6700B 400 W MPS mainframe. able from the front panel when Thanks to the power management operating the N6700 manually or via feature, you can allocate the full computer control. 300 W to the 300 W module while you allocate only 33 W to each of Power management feature allows the 100 W modules. you allocate mainframe power Often, a DUT requires a single high power DC source and several very low power DC sources. Since the DUT does not require full power to all outputs, you may choose to save money configuring a system where 4 Plug high power mainframes Triggering Output disconnect and into standard AC sockets without The N6700 Low-Profile MPS polarity reversal relays dedicated high current AC circuits mainframe has hardware trigger in/ Modules in the N6700 can be When you first turn on the N6702A trigger out signals which permit individually ordered with optional 1200 W MPS mainframe, the main- the N6700 to be synchronized with Output Disconnect Relays (option frame automatically senses the external events. For example, a 761) or Output Disconnect/Polarity power available from the AC line. switch closure in the fixture can Reversal Relays (option 760). See If the AC line voltage is such that trigger the N6700 to apply voltage table on page 25 for option 760 and the resulting current would exceed a to the DUT or take a measurement. 761 availability. All relays are built standard AC outlet rating, the main- into the module, so no additional wir- frame automatically scales back the Drivers ing or rack space is needed to get available output power to prevent The N6700 comes with both the relay function. overloading the AC line. The N6702A VXIplug&play drivers and will limit the output power to 600 W IVI-COM drivers. LabView With option 761, Output Disconnect allowing the high power mainframe drivers are available at NI.COM. Relays, mechanical relays discon- to be plugged into any standard out- nect both the plus and minus side let. This is very convenient for initial Programming language of the power supply, including the bench checkout of the MPS system. The N6700 supports SCPI sense leads. It is also very convenient for test (Standard Commands for development, which is typically done Programmable Instruments). With option 760, Output Disconnect/ on the bench when DUT is not yet Polarity Reversal Relays, mechanical driven to full power. You can also Firmware updates relays switch the leads on both control this power reduction by The N6700 firmware is stored in the plus and the minus side of the manually allocating less than the FLASH ROM and can be easily power supply, including the sense full available mainframe power updated when new features leads, resulting in a voltage polarity among the modules. As a result, become available. Firmware can reversal at the DUT. In addition to the N6702A will draw less power be downloaded into the N6700 polarity reversal, option 760 pro- (and less current) from the AC line. over GPIB, LAN, or USB using the vides the same output disconnect supplied firmware update utility function as option 761. program. Firmware updates can be found at www.agilent.com/find/ Note: Output current is limited N6700firmware. on some modules when option 760 Output Disconnect/Polarity Reversal Relays is installed. See the “Available options” tables at the bottom of page 25 and page 27 for more information about maximum current limitations with option 760. 55 Figure 3. Front panel with up to 4 channels displayed simultaneously (Picture shows 3 channels installed.) Figure 4. Rear panel (Picture shows 3 channels installed.) Front panel Universal AC input Rack mount kit In addition to full control over its The N6700 has a universal input The N6700 is easily rack-mounted three standard interfaces, the N6700 that operates from 100-240 Vac, using available option 908. has a full featured front panel to 50/60/400 Hz. There are no switch- This kit provides all the necessary permit easy manual operation for es to set or fuses to change when hardware to rack mount one N6700 test prototyping, debugging, and switching from one voltage standard mainframe in only 1U of rack space. troubleshooting when used in an to another. The AC input employs This rack mount kit includes front ATE system. You can have confi- power factor correction. rack ears and rear supports which dence that the N6700 is working take the place of standard rack rails properly because you can view the Quick disconnects and/or slides. Note that standard settings and actual output values on Each power module has quick rack rails or slides are not needed all four outputs at the same time. disconnects for easy system setup and are not compatible with the and maintenance. N6700 because of its 1U size and Quieter fans to keep noise down airflow requirements. To reduce acoustic noise, the N6700 mainframes employ fan speed control. When operating at less than full output power, the cooling fans spin slower and generate less noise. Figure 5. Quick disconnects for power and sense leads 6 Choosing the right DC Power Modules to meet your ATE needs See detailed specifications on page 13 N6760 Series N6780 Series For applications where For applications where precision is required multi-quadrant operation and high-precision are required The Agilent N6760 Series of preci- sion DC power modules provides For details on these new products precise control and measurements and how they can be used for in the milliampere and microampere applications including battery drain region with the ability to simulta- analysis and function test, visit neously digitize voltage and current, www.agilent.com/find/N6780 and and capture those measurements in download the N6780 Series Source/ N6750 Series an oscilloscope-like data buffer. Measure Units (SMUs) for the N6700 For applications where the power Modular Power System data sheet, supply plays a critical role literature number 5990-5829EN The Agilent N6750 Series of high- N6730/40/70 Series performance, autoranging DC power For basic DC applications modules provides low noise, high The Agilent N6730, N6740 and accuracy and programming speeds N6770 Series of DC power modules that are up to 10 to 50 times faster provide programmable voltage and than other programmable power current, measurement and protec- supplies. In addition, Agilent has, for tion features at a very economical the first time, included high-speed price, making these modules suit- test extensions in general-purpose able to power the DUT or to power supplies. The high-speed test provide power for ATE system extensions offer an oscilloscope-like resources, such as fixture control. digitizer that simplifies system con- figuration and increases measure- ment accuracy when viewing high- speed transient or pulse events with- in the DUT. In addition, autoranging output capabilities enable one power Figure 6b. User re-configurable supply to do the job of several modular system traditional power supplies. Figure 6a. The N6753A and the N6754A 300 W high-performance autoranging DC power modules each occupy 2 module slots within the mainframe. All other modules occupy 1 module slot. 77 The N6750 and N6760 Series: Performance Modules for when the power supply is a critical part of your testing When your testing requires a Output programming speed Autoranging for flexibility power supply to do more than just When it comes to speed, the The N6750/60 gives test system provide a constant DC level, the N6750/60 achieves performance designers even more flexibility by N6750 Series of high-performance, unlike a typical DC power supply. providing autoranging outputs. This autoranging DC power modules Thanks to an active down-program- autoranging capability provides and the N6760 Series of precision ming circuit to rapidly pull down the maximum output power at any out- DC power modules are the perfect output when lowering the module’s put voltage up to 50 V. This allows fit. These modules combine a fast output voltage, the N6750/60 can one power supply to do the job of output with flexible controls and rapidly program both up and down several power supplies because its sophisticated measurements. The in voltage. Changing voltage from operating range covers low voltage, N6750/60 is more than a power 0 V to 50 V, or 50 V to 0 V, can be high current as well as high voltage, supply; it is a stimulus/response accomplished in less than 1.5 milli- low current operating points. instrument. seconds. And for smaller voltage changes, for example from 0 V to For example, the N6751A high- To fit in 1U, the N6750/60 use an 5 V or 5 V to 0 V, the programming performance, autoranging DC advanced switch-mode design that speed is less than 200 microsec- module, rated at 50 V, 5 A, and offers the low output noise and fast onds. These output speeds allow 50 W can provide full power at output speed typically found on the N6750/60 to give maximum 10 V @ 5 A (=50 W), linear power supplies. system throughput when your test 20 V @ 2.5 A (= 50 W), calls for frequent changes in power 33.3 V @ 1.5 A (= 50 W), Low noise outputs supply voltage settings. 50 V @ 1 A (= 50 W) Careful attention has been paid to or anywhere in between. this design to ensure low normal mode noise (ripple and peak-peak) as well as low common mode noise. Voltage This switching power supply outper- forms most linear power supplies Autoranging 50 W Out on the market. 50 V 50 W Curve 10 V Curre 0 1 A 5 A 8 Therefore, this 50 W autoranging power supply, due to its extended Voltage voltage and current range, can produce voltage and current com- binations in the range of a 250 W non-autoranging power supply. The flexibility of autoranging is useful when the DUT operates over a wide range of voltages, when the ATE system needs to test a wide range of DUTs, or when margin is needed because the ATE power supply must be selected before Time in seconds final DUT power requirements are determined. Figure 7. High speed test extensions LIST mode provides See page 22 for a diagram describ- “power ARB” capability ing the details of the autoranging output characteristics of the N6750 and N6760 Series of DC power output to execute a LIST of voltage The result is an output that auto- modules. and current setpoints. For each matically changes according to the setpoint, a dwell time can be speci- programmed list, just like an arbi- High-speed test extensions fied and the power supply will stay trary waveform generator. To make your testing go even (i.e., dwell) at that setpoint for the faster, the N6750/60 offer High- programmed dwell time value. For * Note that the output response Speed Test Extensions (HSTE). This each setpoint in the LIST, you can time is less than 5 milliseconds enhancement to the N6750/60 DC have a different dwell time from 0 per voltage change, so steps of power modules extends the capabili- to 262 seconds with 1 microsecond less than 5 milliseconds will not ties to include features similar to resolution.* Then, you can trigger achieve their final output voltage a built-in arbitrary waveform gen- the module to begin executing the value before moving on to the erator and a built-in oscilloscope. list. The module will step thru the next step. This is useful when HSTE is optional on the N6750 DC list, staying at each setpoint for the trying to create a smooth power modules. HSTE is standard on programmed dwell time, and then it waveform. the N6760 DC power modules. will move on to the next point. This speeds up execution by removing Through the LIST mode of HSTE, the computer I/O from the process. you can download up to 512 set- points of voltage and current. In LIST mode, you can program the 9 HSTE also provides an oscillo- scope-like digitizer built into the power module to capture voltage and current measurements of up to 4096 points at up to 50,000 measurements per second. For applications such as design validation of battery powered digital devices, the ability to capture dynamic information about the cur- rent flowing into the DUT allows designers to better understand the current drain on DUT batteries and optimize DUT power management during normal DUT operation and in DUT standby mode. The digitizer can also be synchro- nized with changes in the output. Precision low-level performance New source/measure unit For example, the digitizer can make The N6760 Series of Precision DC modules for the most demanding measurements in response to a trig- Power Modules additionally provide applications ger generated by a change in output dual ranges on both programming The N6780 Series of Source/ voltage caused by LIST mode. In and measurement. In the low range, Measure Units offer the highest this configuration, you can ensure these power supplies provide level of performance in the N6700 that measurements are made at the precision in the milliampere and Series. These SMUs feature highly right moment during each step of an microampere regions. They are accurate measurements down to executing LIST. This is particularly ideally suited for semiconductor and nanoamperes while providing useful if you are trying to measure passive device testing, or where operation as a DC voltage source, current consumption during a rap- a precisely controlled output and DC current source, and electronic idly changing voltage stimulus, such highly accurate, precise measure- load. For details on these new prod- as current drawn during a pulsed ments are needed during test. ucts and how they can be used for output voltage. applications including battery drain analysis and functional test, visit www.agilent.com/find/N6780 and download the N6780 Series Source/Measure Units (SMUs) for the N6700 Modular Power System Data Sheet, literature number 5990-5829EN. 10 If you are using Agilent The N6730, N6740 and N6770 Series: multiple-output system Basic modules when you just need a simple DC power supplies now power supply Models Not all applications require high • Performance (programming performance power supplies. When accuracy, measurement accuracy, 6621A, 6622A, 6623A, your budget is tight, and when noise) suitable for most common 6624A, 6625A, 6626A, speed and accuracy are a low DC power applications consideration, the Agilent N6700 6627A, 6628A, 6629A • Built-in optional output disconnect Low-Profile MPS supports basic and polarity reversal relays, which DC power modules that provide an break both the power and the If you would like to take advantage economical solution. The N6730, sense leads, to simplify system N6740 and N6770 Series give you of the size and speed of the N6700, wiring clean, reliable DC power without and need assistance in converting advanced features. from Agilent 662x to the N6700, Use the N6730/40/70 in place of please refer to Application The Agilent N6730 Series of 50 W fixed-output DC power supplies DC power modules, the N6740 Note 1467 – How to use the Many ATE systems have complex Series of 100 W DC power modules, fixtures that contain indicator lights, Agilent N6700 Series modular and the N6770 Series of 300 W relays or active circuits (like power system to replace an DC power modules provide the sensors, triggers, amplifiers) to Agilent 662xA. Look for literature following: facilitate testing of the DUT. These part number 5989-0466EN at circuits need DC power, too. One • Fully programmable constant solution for powering these ATE voltage/constant current DC www.agilent.com/find/N6700 system resources would be to pur- source chase a fixed-output DC source. • Remote sensing for accurate However, there are considerations control of output voltage when when integrating a fixed output voltage drops in the leads are DC source into an ATE system. present • Built-in measurements of voltage and current • Protection (over-voltage over- current, and over-temperature) against damage to your DUT or to the power module 11 11 The table to the right illustrates these Factor Consideration when using a Solution using N6730/40/70 points and how it may be easier, fixed-output DC power supply DC power modules in N6700 MPS faster, and more economical to purchase an N6730/40/70 program- Control the You may want some limited control The N6730/40/70 is fully controllable mable DC power module in place of output over this DC source (on/off). over LAN, USB, GPIB a fixed-output DC power supply. All the benefits of the Monitor the You may want to be able to monitor The N6730/40/70 has built-in N6700 MPS at a low price output the voltage or current to ensure proper measurements of voltage and current, While the N6730/40/70 are operation, which would require wiring eliminating the need for wiring to a economical solutions to basic DC to a system DMM. system DMM. power requirements, they are also part of the N6700 MPS. Therefore, Mounting You will need to mount the power The N6730/40/70 are compact modules while saving, you still have the the power supply in the ATE system. Finding a integrated into a 1U rack mountable benefits of: supply safe location can be a challenge. Some mainframe. There is no need to design system designers will build a “drawer” or build any custom mounting hardware. • Small size (true 1U) or “tray” for holding power supplies. However, this adds extra design time, • Mix-and-match with other N6700 fabrication costs, installation costs, DC power modules when you need and occupies rack space. performance along with basic DC outputs Safety You may want to provide a safety The N6730/40/70 have hardware inputs • Connectivity via LAN, USB, interlock to this DC source. This for remote on/off that can be directly and GPIB would require control (on/off) and a connected to a safety interlock system. • Fast command processing time means to detect the interlock condition. of less than 1 ms • Remote control over internet via standard web browser • Friendly front panel • Optional output disconnect and polarity reversal relays 12 Agilent N6751A/N6752A, N6753A, N6754A and N6761A/N6762A Performance Specifications Unless otherwise noted, specifications are warranted over the ambient temperature range of 0 to 55°C after a 30-minute warm-up period, with each module’s sense terminals externally jumpered directly to their respective output terminals (local sensing). Note: Performance specifications for the N6780 SMU modules can be found at www.agilent.com/find/N6780. See the N6780 Series Source/ Measure Units (SMUs) for the N6700 Modular Power System Data Sheet, literature number 5990-5829EN. N6751A/ N6753A N6754A N6761A/ N6752A N6762A DC output ratings Voltage 50 V 20 V 60 V 50 V Current (derated 1% per °C above 40°C) 5 A / 10 A 50 A 20 A 1.5 A / 3 A Power 50 W / 100 W 300 W 300 W 50 W / 100 W Output ripple and noise (PARD) (from 20 Hz – 20 MHz) CV peak-to-peak 4.5 mV 5 mV 6 mV 4.5 mV CV rms 350 µV 1 mV 1 mV 350 µV Load effect (Regulation) (for any output load change, Voltage 2 mV 2 mV 2 mV 0.5 mV with a maximum load-lead Current (@ 0 - 7 V) 2 mA 12 mA 5 mA 30 µA drop of 1 V per lead) (@ 0 - 50 V) 2 mA 12 mA 5 mA 65 µA Source effect (Regulation) Voltage 1 mV 0.5 mV 1.2 mV 0.5 mV Current1 mA 5 mA 2 mA 30 µA Programming accuracy (at 23°C ±5°C Voltage high range 0.06% + 19 mV 0.06% + 10 mV 0.06% + 25 mV 0.016% + 6 mV after 30 minute Voltage low range (≤ 5.5 V) N/A N/A N/A 0.016% + 1.5 mV warm-up. Applies Current high range 0.1% + 20 mA 0.10% + 30 mA 0.10% + 8 mA 0.04% + 200 µA from min. to max. Current low range (≤ 100 mA, @ 0 - 7 V) N/A N/A N/A 0.04% + 15 µA programming range) (≤ 100 mA, @ 0 - 50 V) N/A N/A N/A 0.04% + 55 µA Measurement accuracy (at 23°C ±5°C) Voltage high range 0.05% + 20 mV 0.05% + 10 mV 0.05% + 25 mV 0.016% + 6 mV Voltage low range (≤ 5.5 V) N/A N/A N/A 0.016% + 1.5 mV Current high range 0.1% + 4 mA 0.10% + 30 mA 0.10% + 8 mA 0.04% + 160 µA NOTE 1 NOTE 2 Current low range (≤ 100 mA, @ 0 - 7 V) N/A N/A N/A 0.03% + 15 µA (≤ 100 mA, @ 0 - 50 V) N/A N/A N/A 0.03% + 55 µA Load transient recovery time (time to recover to within the settling band following a load change) • from 60% to 100% and from 100% to 60% of full load for models N6751A & N6761A • from 50% to 100% and from 100% to 50% of full load for models N6752A-N6754A & N6762A. NOTE 2 NOTE 3 Voltage settling band ± 75 mV ± 30 mV ± 90 mV ± 75 mV Time < 100 µs < 100 µs < 100 µs < 100 µs 1 Applies when measuring 409 6 data points (SENSe:SWEep:POINts = 4096). 2 Settling band is ±125 mV for Model N6752A when relay option 761 is installed. 3 Settling band is ±350 mV for Model N6754A when relay option 760 or 761 is installed. 13 Agilent N6751A/N6752A, N6753A, N6754A and N6761A/N6762A Supplemental Characteristics Supplemental characteristics are not warranted but are descriptions of performance determined either by design or type testing. All supplemental characteristics are typical unless otherwise noted. N6751A/ N6753A N6754A N6761A/ N6752A N6762A Programming ranges Voltage high range 20 mV – 51 V 10 mV – 24.48 V 25 mV – 61.2 V 15 mV – 51 V Voltage low range (≤ 5.5 V) N/A N/A N/A 12 mV – 5.5 V Current high range 10 mA – 5.1 A/ 50 mA – 51 A 20 mA – 20.4 A 1 mA – 1.53 A/ 10 mA – 10.2 A 1 mA – 3.06 A NOTE 1 Current low range (≤ 0.1 A) N/A N/A N/A 0.1 mA – 0.1 A Programming resolution NOTE 2 NOTE 2 NOTE 2 NOTE 3 Voltage high range 3.5 mV 1.5 mV 4.2 mV 880 µV Voltage low range (≤ 5.5 V) N/A N/A N/A 90 µV NOTE 4 NOTE 4 NOTE 4 Current high range 3.25 mA 16.3 mA 6.5 mA 60 µA Current low range (≤ 0.1 A) N/A N/A N/A 2 µA Measurement resolution NOTE 5 NOTE 5 NOTE 5 NOTE 6 Voltage high range 1.8 mV 0.8 mV 2.2 mV 440 µV Voltage low range (≤ 5.5 V) N/A N/A N/A 44 µV Current high range 410 µA 2.05 mA 820 µA 30 µA Current low range (≤ 0.1 A) N/A N/A N/A 1 µA Programming temperature coefficient per °C Voltage high range 18 ppm + 160 µV 20 ppm + 20 µV 20 ppm + 50 µV 18 ppm + 140 µV Voltage low range (≤ 5.5 V) N/A N/A N/A 40 ppm + 70 µV Current high range 100 ppm + 45 µA 60 ppm + 500 µA 60 ppm + 200 µA 33 ppm + 10 µA Current low range (≤ 0.1 A) N/A N/A N/A 60 ppm + 1.5 µA Measurement temperature coefficient per °C Voltage high range 25 ppm + 35 µV 20 ppm + 20 µV 20 ppm + 50 µV 23 ppm + 40 µV Voltage low range (≤ 5.5 V) N/A N/A N/A 30 ppm + 40 µV Current high range 60 ppm + 3 µA 60 ppm + 30 µA 60 ppm + 12 µA 40 ppm + 0.3 µA Current low range (≤ 0.1 A) N/A N/A N/A 50 ppm + 0.3 µA Output ripple and noise (PARD) CC rms 2 mA 10 mA 4 mA 2 mA Common mode noise (from 20 Hz – 20 MHz; rms 500 µA 500 µA 750 µA 500 µA from either output to chassis) peak-to-peak < 2 mA 2 mA 3 mA < 2 mA Over-voltage protection Accuracy 0.25% + 250 mV 0.25% ±150 mV 0.25% ±300 mV 0.25% + 250 mV Maximum setting 55 V 22 V 66 V 55 V Response time 50 µs from occurrence of over-voltage condition to start of output shutdown 1 If you are operating the unit below 255 µA in constant current mode, the output may become unregulated with the following load conditions: The load resistance is <175 mΩ and the load inductance is >20 µH. If this occurs, an UNRegulated flag will be generated and the output current may rise above the programmed value but will remain less than 255 µA. 2 Based on 14-bit DAC, with DAC range adjusted by software calibration 3 Based on 16-bit DAC, with DAC range adjusted by software calibration 4 Based on 12-bit DAC, with DAC range adjusted by software calibration 5 Based on 16-bit ADC (15 bits plus sign), with ADC range adjusted by software calibration 6 Based on 18-bit ADC (17 bits plus sign), with ADC range adjusted by software calibration 14 Agilent N6751A/N6752A, N6753A, N6754A and N6761A/N6762A Supplemental Characteristics (Continued) N6751A/ N6753A N6754A N6761A/ N6752A N6762A Maximum up-programming time with full resistive load (time from 10% to 90% For voltage change of 0 to 10 V 0 to 6 V 0 to 15 V 0 to 10 V of total voltage excursion) Up-programming time 0.2 ms 0.3 ms 0.3 ms 0.6 ms For voltage change of 0 to 50 V 0 to 20 V 0 to 60 V 0 to 50 V Up-programming time 1.5 ms 1.5 ms 2.0 ms 2.2 ms Maximum up-programming settling time with full resistive load (time from start of voltage change For voltage change of 0 to 10 V 0 to 6 V 0 to 15 V 0 to 10 V to within 50 mV of final value) Up-programming settling time 0.5 ms 2.0 ms 2.0 ms 0.9 ms For voltage change of 0 to 50 V 0 to 20 V 0 to 60 V 0 to 50 V Up-programming settling time 4.0 ms 3.0 ms 4.0 ms 4.0 ms Maximum down-programming time with no load (time from start of voltage change For voltage change of 10 to 0 V 6 to 0 V 15 to 0 V 10 to 0 V to output voltage < 0.5 V) Down-programming time 0.3 ms 0.5 ms 0.6 ms 0.3 ms For voltage change of 50 to 0 V 20 to 0 V 60 to 0 V 50 to 0 V Down-programming time 1.3 ms 1.6 ms 2.0 ms 1.3 ms Maximum down-programming settling time with no load (time from start of voltage For voltage change of 10 to 0 V 6 to 0 V 15 to 0 V 10 to 0 V change to output voltage Down-programming settling time 0.45 ms 0.7 ms 0.7 ms 0.45 ms within 50 mV of final value) For voltage change of 50 to 0 V 20 to 0 V 60 to 0 V 50 to 0 V Down-programming settling time 1.4 ms 3.0 ms 3.0 ms 1.4 ms Down-programming time NOTE 1 with capacitive load NOTE 1 NOTE 2 NOTE 3 NOTE 1 (time from start of voltage change Capacitive load 1000 µF 4700 µF 680 µF 1000 µF to output voltage < 0.5 V) For voltage change of 10 to 0 V 6 to 0 V 15 to 0 V 10 to 0 V Down-programming time 0.3 ms 0.5 ms 0.6 ms 0.3 ms For voltage change of 50 to 0 V 20 to 0 V 60 to 0 V 50 to 0 V Down-programming time 1.3 ms 1.6 ms 2.0 ms 1.3 ms Down-programming capability Continuous power 7 W 12.5 W 12.5 W 7 W Peak current 7 A 15 A 6 A 3.8 A Remote sense capability Outputs can maintain specifications with up to a 1-volt drop per load lead. Series and parallel operation Identically rated outputs can be operated directly in parallel or can be connected for straight series operation. Auto-series and auto-parallel operation is not available. 1 Modules can discharge a 1000 µF capacitor from 50 V to 0 V at a rate of 4 times/second. 2 Modules can discharge a 4700 µF capacitor from 20 V to 0 V at a rate of 4 times/second. 3 Modules can discharge a 680 µF capacitor from 60 V to 0 V at a rate of 4 times/second. 15 15 Agilent N6731B – N6736B and N6741B – N6746B Performance Specifications Unless otherwise noted, specifications are warranted over the ambient temperature range of 0 to 55°C after a 30-minute warm-up period, with each module’s sense terminals externally jumpered directly to their respective output terminals (local sensing) N6731B/ N6732B/ N6733B/ N6734B/ N6735B/ N6736B/ N6741B N6742B N6743B N6744B N6745B N6746B DC output ratings: Voltage 5 V 8 V 20 V 35 V 60 V 100 V NOTE 1 NOTE 3 Current 10 A / 20 A 6.25 A / 12.5 A 2.5 A / 5 A 1.5 A / 3 A 0.8 A / 1.6 A 0.5 A / 1 A Power 50 W / 100 W 50 W / 100 W 50 W / 100 W 52.5 W / 105 W 50 W / 100 W 50 W / 100 W Output ripple and noise (PARD) (from 20 Hz – 20 MHz) CV peak-to- peak 10 mV / 11 mV 12 mV 14 mV 15 mV 25 mV 30 mV CV rms 2 mV 2 mV 3 mV 5 mV 9 mV 18 mV Load effect (Regulation) (with output change Voltage 5 mV 6 mV 9 mV 11 mV 13 mV / 16 mV 20 mV / 30 mV from no load to Current 2 mA 2 mA 2 mA 2 mA 2 mA 2 mA full load, up to a maximum load-lead drop of 1 V/lead) Source effect (Regulation) Voltage 1 mV 2 mV 2 mV 4 mV 6 mV 10 mV Current 1 mA 1 mA 1 mA 1 mA 1 mA 1 mA Programming accuracy (@ 23 °C ±5°C after Voltage 0.1% + 19 mV 0.1% + 19 mV 0.1% + 20 mV 0.1% + 35 mV 0.1% + 60 mV 0.1% + 100 mV 30 minute warm-up. Current 0.15% + 20 mA 0.15% + 20 mA 0.15% + 20 mA 0.15% + 20 mA 0.15% + 20 mA 0.15% + 10 mA Applies from minimum to maximum program- ming range) Measurement accuracy (at 23°C ±5°C) Voltage 0.1% + 20 mV 0.1% + 20 mV 0.1% + 20 mV 0.1% + 35 mV 0.1% + 60 mV 0.1% + 100 mV Current 0.15% + 20 mA 0.15% + 10 mA 0.15% + 5 mA 0.15% + 4 mA 0.15% + 4 mA 0.15% + 2 mA Load transient recovery time (time to recover to within the settling band following a load change from 50% to 100% and from 100% to 50% of full load.) NOTE 2 NOTE 2 Voltage settling band ±0.08 V / 0.1 V ±0.08 V / 0.1 V ± 0.2 V / 0.3 V ± 0.2 V / 0.3 V ± 0.4 V / 0.5 V ± 0.5 V / 1.0 V Time < 200 µs < 200 µs < 200 µs < 200 µs < 200 µs < 200 µs 1 Output current is derated 1% per °C above 40°C. 2 Settling band is ±0.10 V/0.125 V for 5 V and 8 V models when relay options 760 and 761 are installed. 3 For N6742B, output current is limited to 10 A when option 760 Output Disconnect/Polarity Reversal Relays is installed. 16 Agilent N6731B – N6736B and N6741B – N6746B Supplemental Characteristics Supplemental characteristics are not warranted but are descriptions of performance determined either by design or type testing. All supplemental characteristics are typical unless otherwise noted. N6731B/ N6732B/ N6733B/ N6734B/ N6735B/ N6736B/ N6741B N6742B N6743B N6744B N6745B N6746B Programming ranges Voltage 15 mV – 5 .1 V 15 mV – 8 .16 V 30 mV – 20.4 V 40 mV – 35.7 V 70 mV – 61.2 V 100 mV – 102 V Current 60 mA – 10.2 A/ 40 mA –6.375 A/ 10 mA – 2.55 A/ 5 mA – 1.53 A/ 2.5 mA – 0.85 A/ 1.5 mA – 0.51 A/ 60 mA – 20.4 A 40 mA – 12.75 A 10 mA – 5.1 A 5 mA – 3.06 A 2.5 mA – 1.7 A 1.5 mA – 1.02 A NOTE 1 Programming resolution Voltage 3.5 mV 4 mV 7 mV 10 mV 18 mV 28 mV Current 7 mA 4 mA 3 mA 2 mA 1 mA 0.5 mA NOTE 2 Measurement resolution Voltage 3 mV 4 mV 10 mV 18 mV 30 mV 50 mV Current 10 mA 7 mA 3 mA 2 mA 1 mA 0.5 mA Programming temperature coefficient per °C Voltage 0.005% + 0.1 mV 0.005% + 0.1 mV 0.005% + 0.2 mV 0.005% + 0.5 mV 0.005% + 0.5 mV 0.005% + 1 mV Current 0.005% + 1 mA 0.005% + 0.5 mA 0.005% + 0.1 mA 0.005% + 0.05 mA 0.005% + 0.02 mA 0.005% + 0.02 mA Measurement temperature coefficient per °C Voltage 0.01% + 0.1 mV 0.01% + 0.1 mV 0.01% + 0.2 mV 0.01% + 0.2 mV 0.01% + 0.5 mV 0.01% + 0.5 mV Current 0.01% + 1 mA 0.01% + 0.5 mA 0.01% + 0.1 mA 0.01% + 0.05 mA 0.01% + 0.02 mA 0.01% + 0.02 mA Output ripple and noise (PARD) CC rms 8 mA 4 mA 2 mA 2 mA 2 mA 2 mA Common mode noise (from 20 Hz – 20 MHz; from either output to chassis) rms 1 mA 1 mA 1 mA 1 mA 1 mA 1 mA peak-to-peak < 15 mA < 10 mA < 10 mA < 10 mA < 10 mA < 10 mA Over-voltage protection Accuracy 0.25% + 50 mV 0.25% + 50 mV 0.25% + 75 mV 0.25% + 100 mV 0.25% + 200 mV 0.25% + 250 mV Accuracy w/opt 760 0.25% + 600 mV 0.25% + 600 mV 0.25% + 350 mV 0.25% + 250 mV 0.25% + 300 mV 0.25% + 300 mV Accuracy w/opt 761 0.25% + 600 mV 0.25% + 600 mV 0.25% + 350 mV 0.25% + 250 mV 0.25% + 300 mV 0.25% + 300 mV Maximum setting 7.5 V 10 V 22 V 38.5 V 66 V 110 V Response time 50 µs from occurrence of over-voltage condition to start of output shutdown Maximum up-programming and down-programming Time with full resistive load (time from 10% to 90% of total voltage excursion) Voltage setting from 0 V to 20 ms 20 ms 20 ms 20 ms 20 ms 20 ms full scale and full scale to 0 V Maximum up-programming and down-programming settling tme with full resistive load (time from start of voltage change until voltage settles within 0.1% of the full-scale voltage of its final value) Voltage setting from 0 V to 100 ms 100 ms 100 ms 100 ms 100 ms 100 ms full scale and full scale to 0 V Remote sense capability Outputs can maintain specifications with up to a 1-volt drop per load lead. Series and parallel operation Identically rated outputs can be operated directly in parallel or can be connected for straight series operation. Auto-series and auto-parallel operation is not available. 1 Based on 12-bit DAC, with DAC range adjusted by software calibration 2 Based on 12-bit ADC (11 bits plus sign), with ADC range adjusted by software calibration 17 17 Agilent N6773A – N6776A Performance Specifications Unless otherwise noted, specifications are warranted over the ambient temperature range of 0 to 55°C after a 30-minute warm-up period, with each module’s sense terminals externally jumpered directly to their respective output terminals (local sensing). N6773A N6774A N6775A N6776A DC output ratings Voltage 20 V 35 V 60 V 100 V NOTE 1 NOTE 3 Current 15 A 8.5 A 5 A 3 A Power 300 W 300 W 300 W 300 W Output ripple and noise (PARD) (from 20 Hz – 20 MHz) CV peak-to- peak 20 mV 22 mV 35 mV 45 mV CV rms 3 mV 5 mV 9 mV 18 mV Load effect (Regulation) (with output change from no load Voltage 13 mV 16 mV 24 mV 45 mV to full load, up to a maximum Current 6 mA 6 mA 6 mA 6 mA load-lead drop of 1 V/lead) Source effect (Regulation) Voltage 2 mV 4 mV 6 mV 10 mV Current 1 mA 1 mA 1 mA 1 mA Programming accuracy: (@ 23°C ±5°C after 30 minute Voltage 0.1% + 20 mV 0.1% + 35 mV 0.1% + 60 mV 0.1% +100 mV warm-up. Applies from minimum Current 0.15% + 60 mA 0.15% + 60 mA 0.15% + 60 mA 0.15% + 30 mA to maximum programming range) Measurement accuracy (at 23°C ±5°C) Voltage 0.1% + 20 mV 0.1% + 35 mV 0.1% + 60 mV 0.1% +100 mV Current 0.15% + 15 mA 0.15% + 12 mA 0.15% + 12 mA 0.15% + 6 mA Load transient recovery time (time to recover to within the settling band following a load change from 50% to 100% and from 100% to 50% of full load.) NOTE 2 NOTE 2 Voltage settling band ± 0.3 V ± 0.3 V ± 0.5 V ± 1.0 V Time < 250 µs < 250 µs < 250 µs < 250 µs 1 Output current is derated 1% per °C above 40°C. 2 Settling band is ±0.35 V for 20 V and 35 V Models when relay options 760 and 761 are installed. 3 For N6773A, output current is limited to 10 A when option 760 Output Disconnect/Polarity Reversal Relays is installed. 18 Agilent N6773A – N6776A Supplemental Characteristics Supplemental characteristics are not warranted but are descriptions of performance determined either by design or type testing. All supplemental characteristics are typical unless otherwise noted N6773A N6774A N6775A N6776A Programming ranges Voltage 30 mV – 20.4 V 40 mV – 35.7 V 70 mV – 61.2 V 100 mV – 102 V Current 30 mA – 15.3 A 15 mA – 8.67 A 7.5 mA – 5.1 A 4.5 mA – 3.06 A NOTE 1 Programming resolution Voltage 7 mV 10 mV 18 mV 28 mV Current 9 mA 6 mA 3 mA 1.5 mA NOTE 2 Measurement resolution Voltage 10 mV 18 mV 30 mV 50 mV Current 9 mA 6 mA 3 mA 1.5 mA Programming temperature coefficient per °C Voltage 0.01% + 0.2 mV 0.01% + 0.5 mV 0.01% + 0.5 mV 0.01% + 1 mV Current 0.01% + 0.5 mA 0.01% + 0.5 mA 0.01% + 0.1 mA 0.01% + 0.1 mA Measurement temperature coefficient per °C Voltage 0.01% + 0.2 mV 0.01% + 0.2 mV 0.01% + 0.5 mV 0.01% + 0.5 mV Current 0.01% + 0.5 mA 0.01% + 0.5 mA 0.01% + 0.05 mA 0.01% + 0.05 mA Output ripple and noise (PARD) CC rms 6 mA 6 mA 6 mA 6 mA Common mode noise (from 20 Hz – 20 MHz; from Rms 2 mA 2 mA 2 mA 2 mA either output to chassis) Peak-to- peak < 20 mA < 20 mA < 20 mA < 20 mA Over-voltage Protection Accuracy 0.25% +100 mV 0.25% + 130 mV 0.25% + 260 mV 0.25% + 650 mV Accuracy w/opt 760 0.25% + 700 mV 0.25% + 700 mV 0.25% + 400 mV 0.25% + 650 mV Accuracy w/opt 761 0.25% + 500 mV 0.25% + 350 mV 0.25% + 350 mV 0.25% + 650 mV Maximum setting 22 V 38.5 V 66 V 110 V Response time 50 µs from occurrence of over-voltage condition to start of output shutdown Maximum up-programming and down-programming time with full resistive load (time from 10% to 90% of total voltage excursion) Voltage setting from 20 ms 20 ms 20 ms 20 ms 0 V to full scale and full scale to 0 V Maximum up-programming and down-programming settling time with full resistive load (time from start of voltage change until voltage settles within 0.1% of the full-scale voltage of its final value) Voltage setting from 100 ms 100 ms 100 ms 100 ms 0 V to full scale and full scale to 0 V Remote sense capability Outputs can maintain specifications with up to a 1-volt drop per load lead. Series and parallel operation Identically rated outputs can be operated directly in parallel or can be connected for straight series operation. Auto-series and auto-parallel operation is not available. 1 Based on 12-bit DAC, with DAC range adjusted by software calibration 2 Based on 12-bit ADC (11 bits plus sign), with ADC range adjusted by software calibration 19 19 Agilent N6700B, N6701A, N6702A MPS Mainframes N6700B, N6701A, N6702A Maximum total output power (= sum of total module output N6700B 400 W when operating from 100 – 240 VAC input power) N6701A 600 W when operating from 100 – 240 VAC input N6702A 1200 W when operating from 200 – 240 VAC input 600 W when operating from 100 – 120 VAC input Command processing time From receipt of command to start ≤ 1 ms of the output change Protection response characteristics INH input 5 µs from receipt of inhibit to start of shutdown Fault on coupled outputs < 10 µs (from receipt of fault to start of shutdown) Digital control characteristics Maximum voltage ratings 16.5 VDC/- 5 VDC between pins (pin 8 is internally connected to chassis ground). Pins 1 and 2 as FLT output Maximum low-level output voltage = 0.5 V @ 4 mA Maximum low-level sink current = 4 mA Typical high-level leakage current = 0.14 mA @ 16.5 VDC Pins 1 - 7 as digital/trigger outputs Maximum low-level output voltage = 0.5 V @ 4 mA; 1 V @ 50 mA; 1.75 V @ 100 mA (pin 8 = common) Maximum low-level sink current = 100 mA Typical high-level leakage current = 0.12 mA @ 16.5 VDC Pins 1 - 7 as digital/trigger inputs and Maximum low-level input voltage = 0.8 V pin 3 as INH input Minimum high-level input voltage = 2 V (pin 8 = common) Typical low-level current = 2 mA @ 0 V (internal 2.2 k pull-up) Typical high-level leakage current = 0.12 mA @ 16.5 VDC Interface capabilities GPIB: SCPI - 1993, IEEE 488.2 compliant interface LXI compliance Class C (applies to mainframes with firmware revision C.00.02 and up) USB 2.0 Requires Agilent IO Library version M.01.01 and up, or 14.0 and up 10/100 LAN Requires Agilent IO Library version L.01.01 and up, or 14.0 and up Built-in web server Requires Internet Explorer 5+ or Netscape 6.2+ Environmental conditions Operating environment Indoor use, installation category II (for AC input), pollution degree 2 Temperature range 0°C to 55°C (current is derated 1% per °C above 40°C ambient temperature) Relative humidity Up to 95% Altitude Up to 2000 meters Storage temperature -30°C to 70°C LED statement Any LEDs used in this product are Class 1 LEDs as per IEC 825-1 20 Agilent N6700B, N6701A, N6702A MPS Mainframes (Continued) N6700B, N6701A, N6702A Regulatory compliance EMC Complies with the European EMC directive 89/336/EEC for Class A test and measurement products. Complies with the Australian standard and carries the C-Tick mark. This ISM device complies with Canadian ICES-001. Cet appareil ISM est conforme à la norme NMB-001 du Canada. Electrostatic discharges greater than 1 kV near the I/O connectors may cause the unit to reset and require operator intervention. Safety Complies with the European Low Voltage Directive 73/23/EEC and carries the CE-marking. This product also complies with the US and Canadian safety standards for test and measurement products. Acoustic noise declaration This statement is provided to Sound Pressure Lp < 70 dB(A), comply with the requirements At Operator Position, Normal Operation, According to EN 27779 (Type Test). * * * of the German Sound Emission Schalldruckpegel Lp <70 dB(A) Directive, from 18 January 1991. Am Arbeitsplatz, Normaler Betrieb, Nach EN 27779 (Typprüfung). * * * Output terminal isolation Maximum Rating No output terminal may be more than 240 VDC from any other terminal or chassis ground. AC input Nominal input ratings 100 VAC – 240 VAC; 50/60 Hz/400 Hz Input range 86 VAC – 264 VAC Power consumption 1000 VA typical (N6700B mainframes) 1500 VA typical (N6701A mainframes) 3000 VA typical (N6702A mainframes) Fuse Internal fuse (not customer accessible) Dimensions Height 44.45 mm; 1.75 in. Width 432.5 mm; 17.03 in. Depth (including handles) 585.6 mm; 23.06 in. (N6700B/N6701A mainframes) 633.9 mm; 24.96 in. (N6702A mainframes) Weight N6700B with 4 installed modules Net: 12.73 kg; 28 lbs. N6701A with 4 installed modules Net: 11.82 kg; 26 lbs. N6702A with 4 installed modules Net: 14.09 kg; 31 lbs. Single-wide power module Net: 1.23 kg; 2.71 lbs Double-wide power module Net: 2.18 kg; 4.8 lbs 21 21 Power Module Autoranging Characteristic Option Characteristics Voltage Output relays (Option 760/761) • Type Autoranging 50 W Ou Double-pole, double-throw 50 V • Location 50 W Curve output & sense terminals Output lists (Option 054): 10 V • Maximum number of steps = 512 Curre • Maximum dwell time in 01 A 5 A seconds = 262 • Maximum list repetitions = 256, Voltage or infinite Autoranging 100 W Ou Digitized measurements (Option 054) 50 V 100 W Curve • Maximum measurement points = 4096 • Maximum sample rate = 50 kHz 12 V 8.5 V Voltage Curre 0 2 A 8.33 A10 A N6753A Autoranging 300 W Output 20 V Voltage 300 W Curve Precision Outputs 50 V 6 V 33 V Curre 0 15 A 50 A Curre Voltage 0 1 A 1.5 A – 50 W output 2 A 3 A – 100 W output N6754A Autoranging 300 W Output 60 V 300 W Curve 15 V Curre 0 5 A 20 A 22 Outline Diagram 549.7 mm 560.2 mm 21.64" 22.06" N6700B/ N6700B/ N6701A N6701A Top of Unit 598.0 mm 608.5 mm 23.96" 23.54" N6702A N6702A 25.4 mm 1.00" 432.5 mm 17.03" 482.6 mm 44.45 m 19.00" 1.75" Agilent Technologies = Airflow 425.45 mm 16.75" 23 23 Right Side Ordering Information Mainframes The N6700 modular power system is available 2 ways: N6700B Low-Profile Modular Power System Mainframe, 400 W Holds 1 to 4 modules. Total available output power = 400 W. (1) You can order an N6700B, N6701A or N6702A mainframe and various N6701A Low-Profile Modular Power System Mainframe, 600 W modules as separate products. Holds 1 to 4 modules. Total available output power = 600 W. (See steps below.) Each item will N6702A Low-Profile Modular Power System Mainframe, 1200 W arrive in a separate box such that Holds 1 to 4 modules. Total available output power = 1200 W. you can assemble the system your- self when you need to. Available options to the N6700B, N6701A, N6702A mainframes (2) You can order an N6710B, N6711A 908 Rack Mount Kit or N6712A system, which is a build- Required for rack mounting. Standard rack mount hardware will not work. to-order system that is shipped as This N6700 Rack Mount Kit is also orderable separately as product N6709A a fully assembled multiple-output FLR Filler Panel Kit power supply. (See pages 26 and 27 Required when you have < 4 modules in a mainframe. Each filler panel kit contains 3 filler panels. for N6710B, N6711A and N6712A This Filler Panel Kit is also orderable as product N6708A. ordering information.) 0L1 Full documentation on CD-ROM and printed Users Guide When ordering the N6700 MPS as 0B0 Full documentation on CD-ROM only; no printed documentation package a mainframe and modules, follow 900 Power Cord, United Kingdom, P/N 8120-1351 these steps: 901 Power Cord, Australia, New Zealand, P/N 8120-1369 Step 1: Select which mainframe you want 902 Power Cord, Europe, Korea, P/N 8120-1689 based on your power requirements. 903 Power Cord, USA, Canada, 120 V, P/N 8120-4383 Step 2: 904 Power Cord, USA, Canada, 240 V, P/N 8120-0698 Select the appropriate documentation 906 Power Cord, Switzerland, P/N 8120-2104 and line cord options. 912 Power Cord, Denmark, P/N 8120-2956 Step 3: 917 Power Cord, South Africa, India, P/N 8120-4211 Order 1 to 4 modules (see next page). If the sum of the power of the modules 918 Power Cord, Japan, 100 V, P/N 8120-5342 exceeds the available output power Note: For model N6702A, the maximum output power is limited to 600 W at 100 Vac. To achieve full output power of 1200 W, you must use option 929 and operate at 200 Vac. rating on the mainframe, see page 4 for an explanation of Agilent’s power 919 Power Cord, Israel, P/N 8120-6800 management capability. Note that each 920 Power Cord, Argentina, P/N 8120-6869 mainframe has 4 module slots to hold modules. Each module occupies one 921 Power Cord, Chile, P/N 8120-6980 module slot, except for the N6753A and 922 Power Cord, China, P/N 8120-8376 the N6754A, which occupy 2 module 927 Power Cord, Thailand, Brazil, P/N 8120-8871 slots per module. 929 Power Cord, Japan, 200 V, P/N 8121-1392 Step 4: Note: This option is available only on model N6702A. For proper operation, you must fill any empty module slots with filler panels. When configuring a mainframe with less Step 5: than 4 filled module slots, you MUST If you will be rack mounting your N6700, order a Filler Panel Kit. Each kit contains you MUST order the Rack Mount Kit. 3 filler panels. Each filler panel fills one empty module slot. 24 Ordering Information Modules Modules Order 1 to 4 modules to be installed in N6730 50 W N6731B 5 V, 10 A, 50 W DC Power Module each N6700B, N6701A or N6702A main- DC power modules N6732B 8 V, 6.25 A, 50 W DC Power Module frame. (To order modules as part of the N6733B 20 V, 2.5 A, 50 W DC Power Module N6710B, N6711A or N6712A build-to- N6734B 35 V, 1.5 A, 50 W DC Power Module order systems, see page 27). If the sum N6735B 60 V, 0.8 A, 50 W DC Power Module of the power of the modules exceeds the N6736B 100 V, 0.5 A, 50 W DC Power Module available output power rating on the mainframe, see page 4 for an explana- N6740 100 W DC power modules N6741B 5 V, 20 A, 100 W DC Power Module tion of Agilent’s power management N6742B 8 V, 12.5 A, 100 W DC Power Module capability. N6743B 20 V, 5 A, 100 W DC Power Module N6744B 35 V, 3 A, 100 W DC Power Module You can individually specify each option N6745B 60 V, 1.6 A, 100 W DC Power Module for each module. For example, you N6746B 100 V, 1 A, 100 W DC Power Module can order one module with Option 761 Output Disconnect Relays while the N6750 high-performance, remaining modules have no relay option. autoranging DC power N6751A 50 V, 5 A, 50 W High-Performance Autoranging DC Power Module modules As your needs change and you want to N6752A 50 V, 10 A, 100 W High-Performance Autoranging DC Power Module change configuration or add more mod- N6753A 20 V, 50 A, 300 W High-Performance ules to existing N6700A, N6700B, N6701A Autoranging DC Power Module or N6702A mainframes, use this order- (occupies 2 module slots in the mainframe) ing information to order the required N6754A 60 V, 20 A, 300 W High-Performance Autoranging DC Power Module modules. (occupies 2 module slots in the mainframe) N6760 precision DC power modules N6761A 50 V, 1.5 A, 50 W Precision DC Power Module N6762A 50 V, 3 A, 100 W Precision DC Power Module N6770 300 W DC power modules N6773A 20 V, 15 A, 300 W DC Power Module N6774A 35 V, 8.5 A, 300 W DC Power Module N6775A 60 V, 5 A, 300 W DC Power Module N6776A 100 V, 3 A, 300 W DC Power Module N6780 Series N6781A 20 V, ± 3 A, 20 W 2-Quadrant DC Power Module 2-quadrant SMUs for Battery Drain Analysis N6782A 20 V, ± 3 A, 20 W 2-Quadrant DC Power Module for Functional Test Available options to N6700 modules N6731B-N6736B N6741B-N6746B N6751A-N6752A N6753A-N6754A N6761A-N6762A N6773A-N6776A N6781A- 50 W DC 100 W DC high-performance 300 W High- precision DC 300 W DC N6782A power modules power modules autoranging DC performance power modules power modules SMUs power modules autoranging DC power modules Output disconnect relays 761 761 761 761 761 761 Standard Output disconnect and polarity reversal relays 760 760 (see note 1, 2) Not available 760 Not available 760 (see note 2) Not available High speed test extensions (HSTE) Not available Not available 054 054 Standard Not available Standard Large size FPGA installed Not available, Not available, LGA (Required, Not available, Not available, Not available, Not available, not required not required see note 3) not required not required not required Commercial calibration with test results data UK6 UK6 UK6 UK6 UK6 UK6 UK6 ISO 17025 Cal certificate 1A7 1A7 1A7 1A7 1A7 1A7 Not available 1 Option 760 is not available on N6741B. 2 When Option 760 is installed in N6742B or N6773A, the maximum output current is limited to 10 A. 3 You must order Option LGA on N6751A and N6752A modules. Option LGA adds a large size FGPA to the module. Option LGA is required to support the Output Sequencing between multiple mainframes. Option LGA will also allow for future expansion for additional firmware features. 25 25 Ordering Information N6700 build-to-order systems Build-to-order systems To purchase an N6700 system, order N6710B System Build-to-order Modular Power System, 400 W an N6710B, N6711A, or N6712A. Consists of 1 N6700B mainframe with total available power of 400 W. These model numbers are build-to-order N6711A System Build-to-order Modular Power System, 600 W systems that are shipped as a fully Consists of 1 N6701A mainframe with total available power of 600 W. tested and assembled multiple-output power supplies. Each system consists N6712A System Build-to-order Modular Power System, 1200 W of one mainframe plus optionally 1 to 4 Consists of 1 N6702A mainframe with total available power of 1200 W. modules. Each mainframe has 4 module slots to hold modules. Each module occupies one module slot, except for the Available options to the N6710B, N6711A, N6712A systems N6753A and the N6754A, which occupy 2 module slots per module. To specify 908 Rack Mount Kit which modules you want installed in Required for rack mounting. Standard rack mount hardware will not work. the system, the modules are ordered as This N6700 Rack Mount Kit is also orderable separately as product N6709A options to the system model number. 0L1 Full documentation on CD-ROM and printed Users Guide If you order less than 4 modules, the empty slots will be automatically filled 0B0 Full documentation on CD-ROM only; no printed documentation package with blank filler panels. You must order 900 Power Cord, United Kingdom, P/N 8120-1351 at least 1 module. 901 Power Cord, Australia, New Zealand, P/N 8120-1369 If the sum of the power of the modules 902 Power Cord, Europe, Korea, P/N 8120-1689 exceeds the available output power 903 Power Cord, USA, Canada, 120 V, P/N 8120-4383 rating on the mainframe, see page 4 for an explanation of Agilent’s power 904 Power Cord, USA, Canada, 240 V, P/N 8120-0698 management capability. 906 Power Cord, Switzerland, P/N 8120-2104 If you prefer to purchase a mainframe 912 Power Cord, Denmark, P/N 8120-2956 and modules as separate pieces, see 917 Power Cord, South Africa, India, P/N 8120-4211 page 24. 918 Power Cord, Japan, 100 V, P/N 8120-5342 Note: For model N6712A, the maximum output power is limited to 600 W at 100 VAC. To achieve full output power of 1200 W, you must use option 929 and operate at 200 VAC. 919 Power Cord, Israel, P/N 8120-6800 920 Power Cord, Argentina, P/N 8120-6869 921 Power Cord, Chile, P/N 8120-6980 922 Power Cord, China, P/N 8120-8376 927 Power Cord, Thailand, Brazil, P/N 8120-8871 929 Power Cord, Japan, 200 V, P/N 8121-1392 Note: This option is available only on model N6712A. 26 Ordering Information Modules as options to Module options for N6710B, N6711A and N6712A systems N6730 50 W N6710B, N6711A or N6712A N6731B–ATO 5 V, 10 A, 50 W DC Power Module DC power modules To order 1 to 4 module as options to an N6732B–ATO 8 V, 6.25 A, 50 W DC Power Module N6710B, N6711A or N6712A, specify N6733B–ATO 20 V, 2.5 A, 50 W DC Power Module its model number, followed by “–ATO.” N6734B–ATO 35 V, 1.5 A, 50 W DC Power Module For example, to order an N6731B as an N6735B–ATO 60 V, 0.8 A, 50 W DC Power Module option to the N6710B, you would specify N6736B–ATO 100 V, 0.5 A, 50 W DC Power Module “N6731B–ATO” as the option. (To order N6740 100 W modules as separate products, see N6741B–ATO 5 V, 20 A, 100 W DC Power Module DC power modules page 25.) If the sum of the power of the N6742B–ATO 8 V, 12.5 A, 100 W DC Power Module modules exceeds the available output N6743B–ATO 20 V, 5 A, 100 W DC Power Module power rating on the mainframe, see N6744B–ATO 35 V, 3 A, 100 W DC Power Module page 4 for an explanation of Agilent’s N6745B–ATO 60 V, 1.6 A, 100 W DC Power Module power management capability. N6746B–ATO 100 V, 1 A, 100 W DC Power Module N6750 high-performance You can individually specify each N6751A–ATO 50 V, 5 A, 50 W High-Performance autoranging DC option for each module. For example, Autoranging DC Power Module power Modules you can order one module with Option N6752A–ATO 50 V, 10 A, 100 W High-Performance Autoranging DC Power Module 761 Output Disconnect Relays while the N6753A-ATO 20 V, 50 A, 300 W High-Performance remaining modules have no relay option. Autoranging DC Power Module (occupies 2 module slots in the mainframe) N6754A-ATO 60 V, 20 A, 300 W High-Performance Autoranging DC Power Module (occupies 2 module slots in the mainframe) N6760 Precision N6761A–ATO 50 V, 1.5 A, 50 W Precision DC Power Module DC power modules N6762A–ATO 50 V, 3 A, 100 W Precision DC Power Module N6770 300 W N6773A–ATO 20 V, 15 A, 300 W DC Power Module DC power modules N6774A–ATO 35 V, 8.5 A, 300 W DC Power Module N6775A–ATO 60 V, 5 A, 300 W DC Power Module N6776A–ATO 100 V, 3 A, 300 W DC Power Module N6780 Series N6781A–ATO 20 V, ± 3 A, 20 W 2-Quadrant DC Power Module 2-quadrant SMUs for Battery Drain Analysis N6782A–ATO 20 V, ± 3 A, 20 W 2-Quadrant DC Power Module for Functional Test Available options to N6700 modules N6731B-ATO N6741B-ATO N6751A-ATO N6753A-ATO N6761A-ATO N6773A-ATO N6781A-ATO to N6736B-ATO to N6746B-ATO to N6752A-ATO to N6754A-ATO to N6762A-ATO to N6776A-ATO N6782A-ATO 50 W DC power 100 W DC power High-performance 300 W High- precision DC 300 W DC power SMUs modules modules autoranging DC performance power modules modules power modules autoranging DC power modules Output disconnect relays 761 761 761 761 761 761 Standard Output disconnect and polarity reversal relays 760 760 (see note 1, 2) Not available 760 Not available 760 (see note 2) Not available High speed test extensions (HSTE) Not available Not available 054 054 Standard Not available Standard Large size FPGA installed Not available, Not available, LGA (Required, Not available, Not available, Not available, Not available, not required not required see note 3) not required not required not required not required Commercial calibration with test results data UK6 UK6 UK6 UK6 UK6 UK6 UK6 ISO 17025 Cal certificate 1A7 1A7 1A7 1A7 1A7 1A7 Not available 1 Option 760 is not available on N6741B-ATO. 2 When Option 760 is installed in N6742B-ATO or N6773A-ATO, the maximum output current is limited to 10 A. 3 You must order Option LGA on N6751A and N6752A modules. Option LGA adds a large size FGPA to the module. Option LGA is required to support the Output Sequencing between multiple mainframes. Option LGA will also allow for future expansion for additional firmware features. 27 27 Compatibility and Upgrade Information Agilent recommends that you keep your N6700 system up to date with the latest firmware available at www.agilent.com/find/N6700firmware. You have with firmware and with modules If you want to … … here is what you need to do N6700A or Any version Any combination of modules Add or change modules to Capability is available with your N6710A of firmware with model number N673xA, mix-and-match any combination current version of hardware and starting with A N674xA, N6751A, N6752A, of modules with model numbers firmware. No upgrade required. (example: A.00.00) or N676xA N673xA, N674xA, N675xA or N676xA Add or change modules to Install firmware version C.02.00 mix-and-match any combination or greater available at of modules with model numbers www.agilent.com/find/N6700firmware N673xA, N673xB, N674xA, N674xB, N675xA, N676xA or N677xA including new modules N6753A and N6754A Add new capabilities Install firmware version C.02.00 • Virtual channel capability or greater available at for paralleling www.agilent.com/find/N6700firmware • Programmable voltage slew capability • Power management capability • Output sequencing across mainframes N6700A or Any version of Any combination of modules Add or change modules to Capability is available with your N6710A firmware B.00.34 with model number N673xA, mix-and-match any combination current version of hardware and or earlier N673xB, N674xA, N674xB, of modules with model numbers firmware. No upgrade required. N6700B or N6751A, N6752A, or N676xA N673xA, N673xB, N674xA, N6710B N674xB, N675xA or N676xA Add or change modules to Install firmware version C.02.00 mix-and-match any combination or greater available at of modules with model numbers www.agilent.com/find/N6700firmware N673xA, N673xB, N674xA, N674xB, N675xA, N676xA or N677xA including new modules N6753A and N6754A Add new capabilities Install firmware version C.02.00 • Power management capability or greater available at • Output sequencing across www.agilent.com/find/N6700firmware mainframes N6700A or C.02.00 or C.01.04 Any combination of modules Add or change modules to Capability is available with your N6710A with model number N673xA, mix-and-match any combination current version of hardware and N673xB, N674xA, N674xB, of modules with model numbers firmware. No upgrade required. N6700B or N675xA, N676xA, or N677xA N673xA, N673xB, N674xA, N674xB, N6710B N675xA, N676xA or N677xA Add new capabilities Capability is available with your N6701A or • Power management capability current version of hardware and N6711A • Output sequencing across firmware. No upgrade required. mainframes N6702A or N6712A Add new modules Install firmware version C.02.00 N6753A and N6754A or greater available at www.agilent.com/find/N6700firmware 28 Compatibility and Upgrade Information (Continued) Agilent recommends that you keep your N6700 system up to date with the latest firmware available at www.agilent.com/find/N6700firmware. You have with firmware and with modules If you want to … … here is what you need to do N6721A Any version Any combination of modules Add more modules with model C a v a a s a l w p b ii e y y a t l h t o i b il u ir through of firmware with model number N675xA numbers N675xA or N676xA current version of hardware and N6729A starting with A or N676xA firmware. No upgrade required. (example: A.00.00) Add or change modules to Install firmware version C.02.00 mix-and-match any combination or greater available at of modules with model numbers www.agilent.com/find/N6700firmware N673xA, N673xB, N674xA, N674xB, N675xA, N676xA or N677xA (see note 1 below) Add new capabilities Install firmware version C.02.00 • Virtual channel capability or greater available at for paralleling www.agilent.com/find/N6700firmware • Programmable voltage slew capability • Power management capability • Output sequencing across mainframes (see note 2 below) Notes: 1 If you add modules with model numbers N673xA, N673xB, N674xA, N674xB, N6753A, N6754A or N677xA, you will not be able to access the Agilent 662x command set capability of your N672xA for any installed modules. Only SCPI commands will be accepted. 2 These features are not available in the Agilent 662x command set. You must use SCPI commands to access these new programmable features. Compatibility with older models Older A version Equivalent configuration with If you previously purchased an Agilent Agilent model model number latest N6700 series models 662xA or N672xA, and you want to make another purchase, use the table 6621A N6721A N6700B + 2 x N6752A at right to find the equivalent configu- 6622A N6722A N6700B + 2 x N6752A ration of N6700B low-profile modular 6623A N6723A N6700B + 2 x N6751A power system mainframe and DC power 1 x N6752A modules. 6624A N6724A N6700B + 4 x N6751A 6625A N6725A N6700B + 1 x N6761A 1 x N6762A 6626A N6726A N6700B + 2 x N6761A 2 x N6762A 6627A N6727A N6700B + 4 x N6751A 6628A N6728A N6700B + 2 x N6762A 6629A N6729A N6700B + 4 x N6762A 29 29 www.agilent.com Remove all doubt Agilent Email U www.agilent.com/find/N6700 Our repair and calibration services www.agilent.com/find/emailupdates will get your equipment back to Get the latest information on the you, performing like new, when products and applications you select. For more information on Agilent promised. You will get full value out Technologies’ products, applications or of your Agilent equipment through- services, please contact your local Agilent Agilent Channel Partners out its lifetime. Your equipment office. The complete list is available at: will be serviced by Agilent-trained www.agilent.com/find/contactus www.agilent.com/find/channelpartners technicians using the latest factory Get the best of both worlds: Agilent’s calibration procedures, automated Americas measurement expertise and product repair diagnostics and genuine parts. You Canada (877) 894 4414 breadth, combined with channel will always have the utmost confidence Latin America 305 269 7500 partner convenience. in your measurements. For information United States (800) 829 4444 regarding self maintenance of this product, please contact your Agilent Asia Pacific office. Australia 1 800 629 485 www.lxistandard.org China 800 810 0189 LXI is the LAN-based successor to Agilent offers a wide range of additional Hong Kong 800 938 693 GPIB, providing faster, more efficient expert test and measurement services India 1 800 112 929 connectivity. Agilent is a founding for your equipment, including initial Japan 0120 (421) 345 member of the LXI consortium. start-up assistance, onsite education Korea 080 769 0800 Malaysia 1 800 888 848 and training, as well as design, system Singapore 1 800 375 8100 integration, and project management. Taiwan 0800 047 866 Thailand 1 800 226 008 For more information on repair and calibration services, go to: Europe & Middle East www.agilent.com/find/removealldoubt Austria 43 (0) 1 360 277 1571 Belgium 32 (0) 2 404 93 40 Denmark 45 70 13 15 15 Finland 358 (0) 10 855 2100 Need a power solution for R&D bench work? France 0825 010 700* The new Agilent N6705B DC Power Analyzer saves time *0.125 €/minute Germany 49 (0) 7031 464 6333 • Provides unrivaled productivity Ireland 1890 924 204 gains for sourcing and measuring Israel 972-3-9288-504/544 DC voltage and current into your Italy 39 02 92 60 8484 DUT by integrating up to 4 advanced Netherlands 31 (0) 20 547 2111 power supplies with DMM, scope, Spain 34 (91) 631 3300 arb, and datalogger features. Sweden 0200-88 22 55 • Eliminates the need to gather multiple Switzerland 0800 80 53 53 pieces of equipment, create complex test United Kingdom 44 (0) 118 9276201 setups including transducers (such as current probes and shunts) to measure Other European Countries: current into your DUT. www.agilent.com/find/contactus • Eliminates the need to develop and debug programs to control a collection Revised: October 1, 2009 of instruments and take useful measurements because all the functions and measurements are available at the front panel. Product specifications and descriptions in this document subject to change without • Modular system: Uses the same DC power modules at the N6700 low-profile notice. modular power system. © Agilent Technologies, Inc. 2007, 2010 Complete specifications can be found in the N6705B DC Power Analyzer Data Printed in USA, July 8, 2010 Sheet, publication 5989-6319EN. For more information go to 5989-1411EN www.agilent.com/find/dcpoweranalyzer

Frequently asked questions

What makes Elite.Parts unique?

chervon down
At GID Industrial (Elite.Parts' parent company), we specialize in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

What kind of warranty will the N6709A have?

chervon down
Warranties differ by part and by which suppliers we use to procure it for you. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carriers does Elite.Parts work with?

chervon down
Elite.Parts can ship via FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Will Elite.Parts sell to me even though I live outside the USA?

chervon down
Absolutely! We are happy to serve customers regardless of location. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

I have a preferred payment method. Will Elite.Parts accept it?

chervon down
All major credit cards are accepted: Visa, MasterCard, Discover, and American Express. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

DC Power Supply

MODULAR DC SOURCE/MONIT.

Rack Mount Kit w/o Front Handles

DC Power Supply, 0-200Vdc, 0-17Amps

DC POWER SUPPLY 0-60V 0-50A 1200W

DC POWER SUPPLY W/RACKMOUNT 0-500V 0-5A 1050W