Elite.Parts chervon right Manufacturers chervon right A chervon right AEMC INSTRUMENTS chervon right OX 7100
About product Datasheet FAQ

AEMC INSTRUMENTS OX 7100

Description

AEMC Instruments OX 7100 Series Portable Oscilloscopes

Part Number

OX 7100

Price

Request Quote

Manufacturer

AEMC INSTRUMENTS

Lead Time

Request Quote

Category

PRODUCTS - O

Datasheet

pdf file

AEMC_Instruments_OX_7100_Series_Portable_Oscilloscopes_datasheet1-1316912335.pdf

1590 KiB

Extracted Text

W A R R A R PORTABLE OsciLLOscOPE OX 7100 series 33  Isolated inputs: 600Vac, 850Vdc to ground and channel-to-channel  Five complementary tools in one: Oscilloscope, Multimeter, FFT Analyzer, Harmonic Analyzer and Recorder  12-bit resolution provides deeper accurate zooming  Sampling rate 1GS/s in one-shot and 25GS/s in ETS with memory depth of 2500 counts per channel in “oscilloscope” mode  Four independent, 4000-count, TRMS, 45kHz, digital multimeters  Color LCD with touch screen functions  33 direct command keys and “Windows-like” menus on screen  Multi-interface communication connector: RS-232, Centronics and Ethernet with web server  Plug-and-play self-identifying and calibrating input probes and accessories E A Y N T Y Features  Isolated inputs; 600Vac, 850Vdc to ground and channel-to-channel  Five complementary tools in one: Oscilloscope, Multimeter, FFT Analyzer, Harmonic Analyzer and Recorder  Sampling rate 1GS/s in one-shot mode and 25GS/s in ETS — memory depth of 2.5k per channel in “oscilloscope” mode  Four isolated measurement channels, 600V Cat III with up to eight traces on screen  12-bit resolution provides deeper accurate zooming  Real-time FFT analysis standard and calculation functions on the channels  Four independent, 4000-count, TRMS, 45kHz, digital multimeters  Color LCD touch screen  33 direct command keys and “Windows-like” menus on screen  Multi-interface communication connector: RS-232, Centronics and Ethernet with web server Field testing is quick and easy thanks to the Model OX 7104-C’s hand strap and the  Stylus for touch screen menu/function use of PrObiX Smart Probes, some that have control buttons, with user definable access and manipulating graphic functions, right on the probes themselves. elements on screen ®  PRObIx smart probes with user AEMC Instruments, a world leader in electrical test and measurement definable control buttons instruments, proudly introduces the first self-contained portable  Plug-and-play self-identifying and four-isolated-channel oscilloscope on the market rated at 600V Cat. III. calibrating input probes and accessories Featuring five complimentary tools in one – an Oscilloscope, FFT Analyzer, TRMS Multimeter, Harmonic Analyzer and a Recorder. The  NATO approved: Model Ox 7104-C is a rugged and ergonomic hand-held instrument Ox 7102-C — 6625 14 549 3558 that is the perfect tool for both laboratory and field testing. Ox 7104-C — 6625 14 549 3559 Ease of use of the instrument is facilitated through 33 specialized keys for direct access to commonly used functions. Ideal for field use, applications the Model Ox 7104-C utilizes the patented new system  On-site contractor maintenance — of “plug-and-play” accessories, individual isolation of each of the industrial or electronic measurement channels and a range of remote management  “Internal” plant maintenance capabilities. The Ethernet link with web server has a number of  Installations and start-up built-in instruments, including a four-channel TRMS multimeter.  Industrial process The large 320 x 240 full color LCD screen provides detailed graphical  Quality control and alphanumerical representations of all measurements and also  Research and laboratory — engineers functions as a touch screen. Using the convenient stylus, the various or technicians “Windows-like” menus can be opened or pulled down and executed.  Field service The stylus can also be used for direct action on graphic elements such as cursors, triggers, zooming, etc. Windows-like menus can be pulled down and executed with the convenient stylus. 2 www.aemc.com Technical Assistance (800) 343-1391 construction Isolated inputs for each channel Hand strap 1/4 VGA (320 x 240) Color LCD Direct access keys to Utility program four instrument modes buttons Charging port Test signal terminals Communications port Trigger mode selection ON/OFF button Shockproof dirt resistant overmold Horizontal and vertical trace adjustments Isolated inputs for each channel rated 600V Cat. III Technical Assistance (800) 343-1391 www.aemc.com 3 oscilloscope Comprehensive triggering functions to record only what is necessary ® The AEMC Instruments Ox 7100 series are the first oscilloscopes in this category to offer sophisticated triggering functions that go beyond primary triggering on a front, or even on a pulse duration. The delay mode allows observation of any event with maximum resolution, even if it occurs long after the actual triggering. For example, the counting mode makes it possible to count events prior to triggering, in order to check the content of digital frames. Triggering can also be associated with a TV signal. Triggering delay in the channel occurs after a delay of 35.2µs with respect to the auxiliary source. This is user programmable. Complete automatic measurements for precise analysis The automatic measurements window displays up to 18 parameters for any signal. For a clear analysis, two markers identify the portion of the signal where the first automatic measurement was made. A specific measurement zone can then be selected by outlining it with manual cursors, for a reliable and more precise result. A direct comparison of two waveforms is performed by checking “variation from reference memory”, in order to display up to 18 parameters of the signal as differences from the reference. Automatic measurement within limits set by the cursors if mathematical functions, scales, or physical units are defined, these measurements allow for them to be directly displayed. This makes a practically infinite number of current and power measurements available with 4-digit resolution, thanks to the 12-bit A to D. 4 www.aemc.com Technical Assistance (800) 343-1391 Math functions In oscilloscope mode, the math functions (1, 2, 3 and 4) can be used on each trace to define a mathematical function and vertical scaling in actual physical unit(s). The real-time on-screen display capability of the math- ematical editor presents four calculated trace results, on which all cursor-selected and automatic measurements are available. It is therefore possible to examine waveforms as power, for example (V x I), and make all associated measurements. Many math functions are available, for example +, -, x, /, as well as sine, cosine, exponent, logarithm, square root, etc., giving access to your exact application. When two channels are multiplied, the result can be displayed Many complex functions can be edited, including the simulation to scale, with its physical unit (kW, for example shown in of a trace from its mathematical equation. Therefore the model math 3), together with the original traces, here the current of an expected result or reference can be stored. All functions and the voltage and calculated wattage are shown. created can be stored practically without limit and retrieved for later use. Real-time Fast Fourier Transform (FFT) for frequency analysis The FFT is used to calculate, at 2,500 points, the discrete representation of a signal in the frequency domain from its representation in the time domain. It is a powerful means to effectively diagnose and analyze signal quality: • measurement of the various harmonics and distortion of a signal • analysis of impulse response • the search for a noise source in logical circuits • and much more Several weighting windows are available including Rectangle, Hanning, Hamming and blackman, along with two representation modes, linear and logarithmic (scale in db). The two cursors can then be used to make precise measurements of frequency spikes, levels, and attenuations, taking advantage of the 80db dynamic range allowed by the 12-bit / 1-GS/s conversion. The autoset makes it easier to obtain an optimum spectral representation on which a graphic zoom can be applied in order to analyze all details of the spectrum. FFT with a Hanning window and a logarithmic scale FFT with a rectangular window and a linear scale Technical Assistance (800) 343-1391 www.aemc.com 5 MultiMeter TRMS Digital Multimeter Pressing the meter key gives access to the multimeter function. The Model Ox 7104 includes a four-channel TRMS digital multimeter where the Model Ox 7102 includes a two-channel digital multimeter — the basic instruments for all diagnostics — measures amplitude (AC and DC voltage and current, power, thermocouples, etc.), resistance, continuity, capacitance and to test components. The PT 100 configuration can be used to measure a temperature based on 100W resistive RTD. All sensors used can be scaled to their true physical unit for optimum application efficiency. Values for each of the multimeters are displayed simultaneously, Parameters for each of the TrMS multimeters can be selected both alphanumerically and graphically. on screen using the stylus and “Windows-like” menus. With the stylus and on-screen “Windows-like” menus, each of the multimeters can be configured quickly and easily. Set the measurement parameters, vertical scale and configure the probes for each channel independently. 6 www.aemc.com Technical Assistance (800) 343-1391 analYZer Harmonic Analyzer (optional) Harmonic analysis is a basic function for all users in the fields of power distribution, electrical engineering and power electronics. With the optional Harmonic Analysis firmware installed, the Model Ox 7104-C can display harmonics up to the 31st for signals having fundamental frequencies between 40 and 450Hz. Harmonic analysis can be displayed on all channels simultaneously, in real-time. Harmonic analysis results are displayed in bargraph form. The status zone indicates: • the total RMS voltage of the signal in V, the total harmonic distortion in % • for the selected harmonic or fundamental, the value in % of the fundamental, the phase in ° with respect to the fundamental, the frequency in Hz, the rMS voltage. recorDer High-Speed Digital Recorder (optional) For users who must track variations of physical or mechanical phenomena, a high-speed digital recorder, with sample rates as fast as 800µs and recording times up to one month, can be incorporated into the instrument. The Recorder offers the ability to monitor thresholds and tolerance windows with triggering of long-term storage of the phenomenon observed and the automatic capture of successive time-stamped faults (510 defaults and up to 127,000 samples). Analysis can be performed on the instrument itself (even mathematical calculations using values from more than one channel) or standard “.TxT” files exported to a spreadsheet. Thanks to the Probix system, the OX 7100 series oscilloscopes manage a wide range of sensors (voltage, current, temperature, 0-10V, 4-20mA, etc.) and displays the signals in their original engineering units (scale and unit). The measurement cursors (the last acquisition and the mobile cursor) can be used with the zoom function to perform a precise analysis of the signals being acquired or already acquired. Technical Assistance (800) 343-1391 www.aemc.com 7 Functional DisplaYs Instrument menus for all functions plus on-line help Display of selected trace Display Trace parameters, Automatic Math Function parameters measurement or Memory, in the color of Menus can be cursor the trace opened and Manual Value of time based graphic elements measurement coefficient (s/div) in cursor can be moved Oscilloscope mode or Frequency (Hz/div) in using the cursor. Cursor FFT mode or automatic Context sensitive display measurements area showing current adjustments Position and Position and movement movement of time trigger of manual cursors Full screen Display Function Full Trace Display Function The FULL SCrEEN feature provides full screen display The FULL TrACE feature activates horizontal splitting of of waveforms, without other information or menus, at the the display screen, allowing you to view waveforms from push of a button. independent channels separately. Zoom Function 8 www.aemc.com Technical Assistance (800) 343-1391 speciFications MODEL OX 7102-c OX 7104-c INTERFACE Screen Specifications Color 5.7” LCD (115 x 86mm) 320 x 240 — CCFL backlighting Display Mode Vectors with interpolation — 500 samples on screen No. of Traces on Screen Four traces and four references — Split screen and full screen modes (tracing zone 110 x 74) Front Panel Control 32 direct shortcuts Screen Control Touch screen — “Windows-like” menus and graphic commands Languages Five complete languages, menus and on-line help (English, French, German, Spanish, Italian) VERTICAL Bandwidth 100MHz Channels Two isolated channels Four isolated channels Input Impedance 1M½ ± 0.5% approx. 17pF Maximum Permanent Input Voltage 600V Cat. III — Derating -20dB/decade from 100kHz Vertical Sensibility 16 ranges from 2.5mV to 200V/div Accuracy ±1.5% Vertical Zoom x5 maximum Probe Factors 1 / 10 / 100 / 1 000 or scaling to any value — Definition of the measurement unit HORIZONTAL Time Base Speed 35 ranges from 1ns/div to 200s/div Accuracy ±1.5% Horizontal Zoom x10 maximum TRIGGERING Mode Auto, trigger, single, Auto 50% Source CH1, CH4 CH1, CH2, CH3, CH4 Type Front, pulse or delay (40ns/20s), count (2/16384) or TV (525 or 625 lines) Coupling AC, DC, HFR, LFR, noise reduction — Hold-off adjustable from 40ns to 1s Sensitivity 0.6 div to 1KHz / 1.5 div to 150MHz DIGITAL MEMORY Maximum Sampling Speed 25GS/s in ETS - 1GS/s in one-shot (on each channel) Vertical Resolution 12 bits Memory Capacity per Channel “TRC” approx. 10kB, “TXT” approx. 20kB User Memory 1MB Other Modes Envelope mode (Factors from 2 to 64) XY Mode Between two from the four traces — math functions and cursors OTHER FUNCTIONS Autoset Complete autoset at less than 3s, with recognition of channels — Frequency > 30Hz FFT Analyzer and Math Functions FFT, + , - , x , / - Editor of mathematical functions Cursors Two or three cursors : V and T simultaneous or Phase Resolution 12-bit, display four digits Automatic Measurements 18 level or time measurements, phase measurements — Resolution 12-bit, display four digits MULTIMETER AC, DC, AC + DC voltage From 400.0mV to 600VRMS or 800Vdc - Accuracy Vdc 0.5 % R+ 5D — bandwidth 45kHz Resistance 80.00 to 32.00M - Precision 0.5 % R+ 25D — Rapid 10-ms continuity test Other Measurements Capacities 5.000nF to 5.000mF/Frequency 45kHz — Diode test 3.3V RECORDER (optional) Acquisition Rate Sampling interval from 800µs to 18mn approximately Duration of Recording From 2s to 31 days Acquisition Mode Conditional on thresholds or windows — Normal or “510-faults” acquisition Operation Time stamped graphic recording, conversion and units of physical quantities, measurement using cursors and search for events, standard file format usable in spreadsheets (.TXT) HARMONIC ANALYZER (optional) Analysis Span Even or odd orders up to 31, or first 16 orders Operation Permanent display: total RMS value and total harmonic distortion — Order selected: % F, phase, freq, VRMS GENERAL SPECIFICATIONS Configurations Memories Unlimited — “.CFG” file size approx. 1kB Ethernet Network Printing (standard) 11 black and white or color drivers : IBM Proprinter, Epson ESC/P, Canon HP PCL, Seiko DPU411, RS-232 or Centronics (options) Postscript Image files: “.BMP” 10kB, “.GIF” approx. 5kB (storage in memory transfer by RS-232 or Ethernet) Communication Local via Ethernet 10 MB or RS 232 (option) — Remote via 10 MB Ethernet and web server included “SX-METRO” application software for PC (option) Power Source 9.6V/3.8 A/h battery pack — Approx. 4h between charges — Adjustable power-saving switching Multi-voltage 98-254V / 47-63Hz — Fast charge in two hours (oscilloscope off) Dimensions 10.25 x 7.25 x 2” (261 x 185 x 53mm) Weight 4.2 lbs (1.9kg) with batteries Technical Assistance (800) 343-1391 www.aemc.com 9 soFtWare The Ethernet interface and its web server offer new ways of working and communicating, local or remote, with a convenience and effectiveness that will quickly make them necessities. All that is needed for communication is that the other equipment (printer, PC, etc.) has an IP address. Thus, even on the road, you can print results on a network printer, exchange files between the Ox 7100 series oscilloscopes and a computer. You can also monitor the instrument remotely from any PC, display the traces in real-time and control it using the instrument panel. Whether locally or at a distance, these transfer and exchange operations are simple and rapid and do not require special software on the computer, thanks to the web server. real-time display of all active channels by using SX METrO software supplied Snapshot display of multiple waveforms and FFT data using SX METrO software For the first time, these portable oscilloscope tools for industrial and electronic maintenance eliminate the traditional problems of printing, backing up and documenting traces due to the incorporation of internet and LAN interface. in the oscilloscope, multimeter, analyzer and recorder modes, the web server ensures unparalleled effectiveness, very simply, with no need to install software on the local or remote PC. 10 www.aemc.com Technical Assistance (800) 343-1391 proBiX sYsteM smart Probes & Adapters The PROBIX system is your assurance that using the instrument will not only be rapid but also, more importantly, error-free, which is critical for devices used for troubleshooting. For unfailing compatibility, the connection of bNC connectors or standard test leads is accomplished using the safety adapters provided. An interchangeable plastic ring can be used to match the color of the accessory to the color of its channel. Power is supplied and the sensors are calibrated directly from the oscilloscope. Some accessories have three control buttons accessible on the probe itself. Automatic recognition of sensors and connection accessories: Probix probes and adapters are plug-and-play and are recognized immediately when connected. The instrument not only identifies them, but also configures to their characteristics. Active safety is built in, no- tably in the form of safety information and recommendations concern- ing the accessory used. A pop-up screen displays: • the maximum input voltage • the maximum voltage to ground • the maximum voltage between channels • the type of sensor being used • the use of a suitable safety lead Configuration of the channels and management of the sensors: The coefficients, scales and units of the sensors and the channel configurations are managed automatically. The first two control but- tons on the probes are used to directly modify the adjustment param- eters of the channel to which they are connected or to copy functions from the front panel of the oscilloscope. The third button is specific to the accessory. On voltage probes, for example, it controls the lighting of the measurement area. When the connection is made, all preferred parameters stored in the accessories (assignments of buttons one and two, color) are automatically reactivated. They can be modified using the Probix “pop-up” shown to the right. Technical Assistance (800) 343-1391 www.aemc.com 11 ORDERiNG iNFORMATiON cATALOG NO. Portable Oscilloscope Model OX 7102-C (Two 100MHz, Color) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2124.50 Includes: Oscilloscope; one PRObIx PRHx1, 1/10 Probes, 250MHz, 600V Cat. III; one PRObIx bNC adapters; one PRObIx 4mm banana plug adapter; one US power adapter (115V, 60Hz); one battery pack, NiMH 19.6V, 3.8Ah; one set-of-two color-coded leads, 1.5m (red/black) with needle probe tips; one crossed Ethernet cable; one RS-232/9-pin D-SUb cable; set of two stylus; aluminum carrying case, three-year product warranty and registration card and user manual on CD-ROM Portable Oscilloscope Model OX 7102-C Kit (Two 100MHz, Color — Kit) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2124.53 ® Includes: AEMC Cat. #2124.50 (above), plus one straight Ethernet cable; Sx-METRO data processing and analysis software and one set-of-two grip probes (red/black) Portable Oscilloscope Model OX 7104-C (Four 100MHz, Color) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2124.54 Includes: Oscilloscope; two PRObIx PR, 1/10 Probe, 250MHz, 600V Cat. III; two PRObIx bNC adapters; one PRObIx 4mm banana plug adapter; one US power adapter (115V, 60Hz); one battery pack, NiMH 19.6V, 3.8Ah; one set-of-two color-coded leads, 1.5m (red/black) with needle probe tips; one crossed Ethernet cable; one straight Ethernet cable; Sx-METRO data processing and analysis software; one RS-232/9-pin D-SUb cable; one set-of-two grip probes (red/black); set of two stylus; aluminum carrying case, three-year product warranty and registration card and user manual on CD-ROM Portable Oscilloscope Model OX 7104-C Power Kit (Four 100MHz, Color — Kit) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2124.63 ® Includes: AEMC Cat. #2124.54 (above), plus the Ox Power Kit (Cat. #2124.88) which includes two PRObIx PRHx1, 1/10 Probe, 250MHz, 600V Cat. III; two PRObIx 4mm banana plug adapters; three PRObIx current probes, 20mA to 80A, 100kHz; one PRObIx PRHx7, K thermocouple adapter; three set-of-two color-coded 1.5m leads and clips (red/black 4mm straight, 4mm right angle); small classic tool bag Accessories (Optional) Sx-METRO/P Software, Data Retrieval Processing ........................................................ 2124.70 Harmonic Analyzer, Firmware — upgrade . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2124.71 Recorder Function, Firmware — upgrade . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2124.72 PRObIx PRHx1, 1/10 Probe, 250MHz, 1000V Cat. II (600V Cat. III) .......................................... 2124.73 PRObIx PRHx4, bNC adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2124.74 PRObIx PRHx5, 50W adapter ........................................................................ 2124.75 PRObIx banana Plug (4mm) adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2124.76 PRObIx Current Probe, 20mA to 20A peak, 100kHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2124.77 PRObIx PRH7, K thermocouple adapter ................................................................ 2124.78 Carrying Case, Aluminum with foam cut-outs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2124.79 Ethernet Cable, straight ............................................................................. 2124.80 Ethernet Cable, crossed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2124.81 RS-232 Adapter/Centronics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2124.82 RS-232 Cable/9-pin D-SUb cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2124.83 Leads, set of two, color-coded (1.5m) (black and red, 4mm straight, 4mm right angle) with color-coded safety alligator clips (black and red) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2124.84 Leads, set of two, color-coded (1.5m) (black and red) with Needle Probe Tips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2124.85 Grip Probes, set of two, color-coded (black and red) ....................................................... 2124.86 Ox Power Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2124.88 Metallic carrying case holds the oscilloscope and all accessories. ® Call the AEMC Instruments Technical Assistance Hotline for immediate consultation with an applications engineer: (800) 343-1391 Export Department: (978) 526-7667 • Fax (978) 526-7605 • E-mail: export@aemc.com ® ® Chauvin Arnoux , Inc. d.b.a AEMC Instruments • 200 Foxborough Blvd. • Foxborough, MA 02035 USA • (800) 343-1391 • (508) 698-2115 • Fax (508) 698-2118 Visit our website at www.aemc.com 950.bR-SCOPE_0108Rev02 Printed in the USA ™ Chauvin Arnoux One Source

Frequently asked questions

What makes Elite.Parts unique?

chervon down
At GID Industrial (Elite.Parts' parent company), we specialize in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

What kind of warranty will the OX 7100 have?

chervon down
Warranties differ by part and by which suppliers we use to procure it for you. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carriers does Elite.Parts work with?

chervon down
Elite.Parts can ship via FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Will Elite.Parts sell to me even though I live outside the USA?

chervon down
Absolutely! We are happy to serve customers regardless of location. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

I have a preferred payment method. Will Elite.Parts accept it?

chervon down
All major credit cards are accepted: Visa, MasterCard, Discover, and American Express. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

AEMC Instruments Oscilloscopes

AEMC OT-1 Outlet Tester Model (110V US) (#2121.02) - Gold Level Price!

Outlet Tester Model OT 1 110V US RoHS Compliant: NA

AEMC OT-2 Outlet & GFCI Tester Model (110V US) (#2121.03) - Gold Level Price!

Outlet & GFCI Tester Model OT 2 110V US RoHS Compliant: NA

AEMC OX7102-C Portable Oscilloscope 2 x 100 MHz, Color (Catalog# 2124.50)