ADC PWX-001RGCSD10PWDP Circuit Breaker. Dual Power Feed | 10/10 position GMT | Front & Rear Access | 2 Hole Compression Lug Input | Screw Down output | Wire Wrap Alarm contact | Power On & Fuse Alarm LEDs | Putty White

Part Number

PWX-001RGCSD10PWDP

Price

Request Quote

Manufacturer

ADC

Lead Time

Request Quote

Category

POWER DISTRIBUTION

Specifications

Configuration

Dual power feed, 10/10 position fuse configuration

Features

Datasheet

pdf file

PWX-001RGCSD10PWDP-d-2082577618s.pdf

6189 KiB

Extracted Text

® PowerWorx Power Distribution Products 3rd Edition CoPPer ConneCtivity ® PowerWorx Power Distribution Products table of Contents Introduction .......................................................................................................................................... 1 ® PowerWorx Traditional GMT Series...................................................................................................3 Specifications ...................................................................................................................................... 4 Drawings and Sample Configurations ................................................................................................. 5 ordering information .......................................................................................................................... 6 PowerWorx Uninterrupted Power GMT Series ................................................................................. 7 Specifications ...................................................................................................................................... 8 Drawings and Sample Configurations, ordering information .............................................................. 9 ™ PowerWorx SuperPower GMT Series ............................................................................................ 10 Specifications .................................................................................................................................... 11 Drawings and Sample Configurations ............................................................................................... 12 ordering information .......................................................................................................................... 1 ™ PowerWorx Select Series ................................................................................................................. 14 Specifications .................................................................................................................................... 15 Drawings and Sample Configurations ............................................................................................... 16 Drawings and Sample Configurations, ordering information ............................................................ 17 PowerWorx Select Series with Low Voltage Disconnect ............................................................... 18 Specifications .................................................................................................................................... 19 images and ordering information ..................................................................................................... 20 PowerWorx Modular Front Access Power Distribution Panel ....................................................... 21 Specifications .................................................................................................................................... 26 Drawings and Sample Configurations, ordering information ............................................................ 27 PowerWorx Select Series Circuit Breaker ........................................................................................ 24 Specifications .................................................................................................................................... 22 Drawings and Sample Configurations ............................................................................................... 23 Sample Configuration ....................................................................................................................... 24 PowerWorx Advantage Series .......................................................................................................... 28 Specifications .................................................................................................................................... 29 Drawings and Sample Configurations ............................................................................................... 30 ordering information ........................................................................................................................ 31 PowerWorx GMT 60eSeries ............................................................................................................... 32 Specifications .................................................................................................................................... 33 ordering information ........................................................................................................................ 34 PowerWorx DSX PDP Series Specification and ordering information ............................................................................................ 35 PowerWorx Accessories Cable Management Bars For Standard .............................................................................................. 36 Compression Lugs For two-Hole Stud-type input Power Connections .............................................. 36 Designation Card Holder and Cards .................................................................................................. 36 GMt Fuses/Fuse Designation Pins – Alarm indicator ......................................................................... 37 GMt Designation Pin Holder ............................................................................................................. 37 GMt Fuse Puller ................................................................................................................................ 37 KLM Fuses – non-indicator ............................................................................................................... 38 KLM Fuse Panel Cap ......................................................................................................................... 38 rear Covers ....................................................................................................................................... 38 ring Lug Kit ...................................................................................................................................... 38 tPA Fuses – Alarm indicator .............................................................................................................. 39 ™ PowerWorx Advantage Series Accessories Carling Breakers and tPC Fuses/Fuse Holder ..................................................................................... 40 Compression Lugs For two-Hole Stud-type input Power Connectionsr ............................................. 41 Miscellaneous Accessories ................................................................................................................. 41 w w w. a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1 iii ® PowerWorx Power Distribution Products introduction As networks and the variety of powered network devices grow, so does the need Features for reliable power distribution and protection • Up to a 15-year warranty in multimedia broadband networks. ADC’s PowerWorx power distribution products • Compliant with all major standards, including have been engineered from the ground UL, neBS Level 3, telcordia (BellCore), neC up to properly protect and distribute 2002, CSA, ieC, and Ce power to valuable, revenue-generating • Backed by ADC quality, manufacturing network equipment. excellence and exceptional customer service • Flexible platform for use in central offices, PowerWorx panels are independently tested headends, hubs, remote sites, etc. to comply with the industry’s highest standards, including Ce, ieC, UL, neBS Level 3, telcordia (BellCore), CSA, and neC 2002. Flexible PowerWorx configurations suit almost every network application and the platform sets a new standard – delivering the power and the protection that service providers need. PowerWorx Platform Decision Matrix Choose Platform Fuse Panel Up to 100 Amps/BUS Up to 300 Amps/BUS Circuit Breaker Panel High Amperage ™ Fuse/Breaker Panel • Select Series ™ Circuit Breaker Platform • Advantage Series Fuse and Circuit Breaker Platform Choose Maximum Input Amperage Up to 65 Amps/BUS Up to 100 Amps/BUS (GMt Fuses) (GMt, KLM, tPA Combo Fuses) Choose Uninterrupted Choose Fusing Capabilities ™ • SuperPower GMt Panel (GMt Fuses) Yes No • • Uninterrupted Power traditional GMt Panel GMt Panel ™ • Select Series Fuse Platform • Bay Alarm (traditional GMt Panel) • Low voltage Disconnect Panel (GMt, tPA and GMt/tPA Combo Fuses) • non-neBS GMt Panel (international Applications) • Modular Panel w w w. a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1 1 ® 10/09 • 105203AE PowerWorx Power Distribution Products ® PowerWorx Platform At a glance Max. Max. Max. Max. Max. Input Output GMT KLM TPA Circuit Other Voltage Amp. Amp. Access Positions Positions Positions Breakers Features ±24 or Traditional 65 A 15 A Standard Single n/A n/A n/A GMT 48 vDC and 40, Front Dual 20 set-screw Uninterrupted -24/ 60 A 15 A Standard Dual 10 n/A n/A n/A Uninterrupted -48 and Power vDC Front ™ ±24 or SuperPower 100 A 15 – 20 Standard Dual 20 n/A n/A n/A 48 vDC A and Front ™ Select Series -24/ 100 A 50 A* Standard Dual 10 Dual 5 Dual 4 n/A Fuse -48 vDC ™ Select Series ±24 or 100 A 50 A Standard n/A n/A n/A Dual 8 48 vDC Breaker ™ Select Series -48 2 x 75 50 A* Standard Dual 5 n/A Dual 4 n/A LvD LVD vDC A per side Modular -48 2 x 75 50 A* Front Dual 8 n/A Dual 4 n/A LvD LVD vDC A per side Advantage -48 300 A 125 A Standard Dual 4 n/A n/A Dual 6 ™ Series vDC GMT 60e -48 60 A 15 A Standard Dual 20 n/A n/A n/A vDC DSX PDP -42 60 A 3 A Standard Single 20 n/A n/A n/A to -56 vDC *GMt=10 -15 A KLM = Up to 30 A tPA = Up to 50 A Note: Don’t forget about the input/output rule: the combined outgoing voltage cannot exceed what is coming in from the Battery Distribution Fuse Bay (BDFB) w w w. a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1 2 ® 10/09 • 105203AE PowerWorx Power Distribution Products ® PowerWorx traditional GMt Series With input power up to 65 Amps per bus, the traditional GMt Series eliminates the need to stock varying amperage fuse panels. Fuse management is simplified by accommodating up to 15 Amps of output power per fuse position – without the need to space fuses. A self-configuring voltage and polarity feature allows a single panel to support most applications, providing ±24vdc or ±48vdc power. w w w. a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1 3 ® 10/09 • 105203AE PowerWorx Power Distribution Products ® PowerWorx traditional GMt Series Specifications PHYSICAL Dimensions (HxWxD) Standard access: 1.75" x 17.12" x 8" (44 x 435 x 203 mm) total-front-access: 3.5" x 21.25" x 4" (89 x 540 x 102 mm) Dimensions do not include depth of power connectors, alarm lamps or fuses. Weight: Approximately 10 lbs (4.5 kg) Rack Mounting Width: Standard Access and PWX-n01FGCSD10PSPD: 19" or 23" (483 or 584 mm) flush or recess-mountable with universal mounting brackets. eiA/WeCo or etSi mounting options available. total-front-access: 23" (584 mm) only (except PWX-n01FGCSD10PSDP). Housing Material: Cold-rolled 16 gauge steel. Polycarbonate protective cover provided with all panels. Housing Finish: Putty white or black powder-coat POWER 1 Fuse Capacity : 0.2 to 15 Amps (see chart below for details) Panel Capacity: 65 Amps (maximum) per bus Operating Voltage: ±24 vdc (±21 to ±30 vdc tolerance) or ±48 vdc (±42 to ±56 vdc tolerance) Power Dissipation: 40 watts maximum Fail Alarm Indicators: red LeD indicates blown fuse. Green LeD indicates power on. Alarm output contacts provided for audible, visual and remote alarms. Alarm Contact Connection: Wire-wrap or screw-down barrier terminal strip Alarm Contact Relay: 1 Amp maximum Input Feed Connection: two-hole compression-lug (stud-type) accepts range of wire up to 2 AWG. Set screw barrel connector accepts range of wire up to 6 AWG. Panel ships with two 2-hole lugs (accepting 6 AWG wire) per power bus. Output Feed Connection: Screw-down barrier terminal strip or set screw barrel terminal strip accepts range of wire up to 12 AWG. Grounding: two-post grounding accepts range of wire up to #10 AWG for single connection; two-hole compression lug (stud-type) accepts wire up to #2 AWG. Fuse Output Max. Amperage Range Of Bare Post/ Distance Between Configuration Connector Type Per Fuse Position Wire Accepted Stud Size Barriers Walls S10, D10 Screw-Down 15 Amps 12-22 AWG #6-32 0.325" (8 mm) S10, D10 Set Screw 15 Amps 12-24 AWG nA nA S20 Screw-Down 15 Amps 12-20 AWG #6-32 0.325" (8 mm) S20 Set Screw 15 Amps 12-24 AWG nA nA S40 Screw-Down 10 Amps 16-24 AWG #3-48 0.20" (5 mm) S40 Set Screw 15 Amps 12-24 AWG nA nA D20 Screw-Down 10 Amps 16-24 AWG #3-48 0.20" (5 mm) D20 Set Screw 15 Amps 12-24 AWG nA nA ENVIRONMENTAL Storage Temperature: -45° to 85°C (-49 to 185º F) Operating Temperature: -5° to 55°C (23 to 131º F) Operating Humidity: 0% to 95%, non-condensing Operating Altitude: Up to 13,000 feet (3.96 km) STANDARDS: Meets UL, telcordia (Bellcore), neC 2002, CSA, neBS Level 3, ieC, and Ce standards WARRANTY: 15 years 1 Important Note: the fuse manufacturer recommends that fuses be continuously operated at no more than 80% of their nominal current rating. w w w. a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1 4 ® 10/09 • 105203AE PowerWorx Power Distribution Products 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 15 AMP MAX� PER FUSE FUSE ALARM FUSE INSTALLED UPSIDE-DOWN 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 15 AMP MAX� PER FUSE FUSE ALARM FUSE INSTALLED UPSIDE-DOWN TORQUE TO 16.0 lb-in (2.0 Nm) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 2 0 BATT BATT C.GND C.GND RTN 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 2 0 RTN NO C NC NO C NC FUSE ALARM INPUT VOLTAGE: POS OR NEG/24 OR 48VDC TORQUE TO 4.5 lb-in (0.5 Nm) TORQUE TO 16.0 lb-in (2.0 Nm) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 2 0 BATT BATT C.GND C.GND RTN 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 2 0 RTN NO C NC NO C NC INPUT VOLTAGE: POS OR NEG/24 OR 48VDC FUSE ALARM TORQUE TO 4.5 lb-in (0.5 Nm) 1 2 3 4 5 6 7 8 9 1 0 1 2 3 4 5 6 7 8 9 1 0 15 AMP MAX� PER FUSE FUSE ALARM-A POWER-A FUSE ALARM-B POWER-B FUSE INSTALLED UPSIDE-DOWN FUSE INSTALLED UPSIDE-DOWN ® PowerWorx traditional GMt Series 1 2 3 4 5 6 7 8 9 1 0 1 2 3 4 5 6 7 8 9 1 0 15 AMP MAX� PER FUSE FUSE ALARM-A POWER-A FUSE ALARM-B POWER-B FUSE INSTALLED UPSIDE-DOWN FUSE INSTALLED UPSIDE-DOWN Front view MAX INPUT 65A MAX INPUT 65A 1 2 3 4 5 6 7 8 9 10 NO C NC 1 2 3 4 5 6 7 8 9 10 AUDIO� BATT�BATT�VISUAL� B�REMOTE A� RTN RTN ALARM C.GND C.GND 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 INPUT VOLTAGE POS OR NEG / 24 OR 48 VDC INPUT VOLTAGE POS OR NEG / 24 OR 48 VDC rear view Standard 10/10-Position Dual rear Power Feed PWX-001rGCSD10PWDP MAX INPUT 65A MAX INPUT 65A NO C NC 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 AUDIO� BATT�BATT�VISUAL� B�A�REMOTE RTN RTN ALARM C.GND C.GND 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 INPUT VOLTAGE POS OR NEG / 24 OR 48 VDC INPUT VOLTAGE POS OR NEG / 24 OR 48 VDC Front view total-Front-Access 10/10-Position Dual Power Feed PWX-001FGCSD10PWDP Front view rear view Standard Single 10 rear Power Feed PWX-001rGCSS10PWDP Front view rear view Standard 10/10-Position Dual rear Power Feed PWX-001rGCSD20PWDP w w w. a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1 5 ® 10/09 • 105203AE PowerWorx Power Distribution Products ® PowerWorx traditional GMt Series Ordering Information Traditional GMT Series Standard front and rear access fuse panels Shipping Catalog Number Dual power feed, 10/10 position fuse configuration Quick Ship Wire-wrap alarm connection Putty White PWX-001rGCSD10PWDP Black Standard PWX-001rGCSD10PWDB Dual power feed, 10/10 position fuse configuration Screw-down barrier terminal strip alarm contact connection Putty White Standard PWX-001rGCSD10PSDP Black Standard PWX-001rGCSD10PSDB Dual power feed, 20/20 position fuse configuration Wire-wrap alarm connection Putty White Standard PWX-001rGCSD20PWDP Total front access fuse panels Dual power feed, 10/10 position fuse configuration Putty white See alarm contact connection options below Screw-down barrier terminal strip Standard PWX-n01FGCSD10PSDP Wire-wrap Standard PWX-002FGCSD10PWDP note: Panels ship with dummy fuses installed in all positions, one fused equipment designation card holder and card, a voltage designation label, two 2-hole lugs per power bus, two ring lugs (for grounding), and one designation pin holder per fuse holder. other custom configurations available. For more information call ADC at 1-800-366-3891 w w w. a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1 6 ® 10/09 • 105203AE PowerWorx Power Distribution Products ® PowerWorx Uninterrupted Power GMt Series to ensure constant powering of fused network equipment, the Uninterrupted Power GMt Series features two input power feeds. if power to one fails, the other serves as backup – taking on the load of the failed circuit while maintaining its own load. Schottky-steering diodes ensure panel uptime until input power is restored, while a patent-pending heat dissipation design ensures safety. the panel offers input power up to 60 Amps per bus. w w w. a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1 7 ® 10/09 • 105203AE PowerWorx Power Distribution Products ® PowerWorx Uninterrupted Power GMt Series Specifications PHYSICAL Dimensions (HxWxD) Standard access: 1.75" x 17.12" x 10" (44 x 435 x 254 mm) total-front-access: 3.5" x 21.25" x 5.17" (89 x 540 x 131 mm) Dimensions do not include depth of power connectors, alarm lamps or fuses Weight: Approximately 11 lbs (4.5 kg) Rack Mounting Width: Standard Access: 19" or 23" (483 or 584 mm) flush or recess-mountable with universal mounting brackets. eiA/WeCo or etSi mounting options available total-front-access: 23" (584 mm) flush or recess-mountable into eiA and WeCo racks Housing Material: Cold-rolled 16 gauge steel. Polycarbonate protective cover provided with all panels Housing Finish: Putty white or black powder-coat POWER 1 Fuse Capacity : 0.2 to 15 Amps Panel Capacity: 60 Amps (maximum) per bus Operating Voltage: -24 vdc (-21 to -30 vdc tolerance) or -48 vdc (-42 to -56 vdc tolerance) Power Dissipation: 40 watts maximum Fail Alarm Indicators: red LeD indicates blown fuse. Green LeD indicates power on Alarm Contact Connection: Wire-wrap alarm output contacts provided for audio, visual and remote alarms Alarm Contact Relay: 1 Amp maximum Input Feed Connection: two-hole compression-lug (stud-type) accepts range of wire up to 2 AWG. Set screw barrel connector accepts range of wire up to 6 AWG. Panel ships with two 2-hole lugs (accepting 6 AWG wire) per power bus. Output Feed Connection: Screw-down barrier terminal strip accepts range of wire up to 12 AWG Grounding: two-post grounding accepts range of wire up to #10 AWG for single connection; two-hole compression lug (stud-type) accepts wire up to #2 AWG. Fuse Output Max. Amperage Range Of Bare Post/ Distance Between Configuration Connector Type Per Fuse Position Wire Accepted Stud Size Barriers Walls D10 Screw-Down 15 Amps 12-22 AWG #6-32 0.325" (8 mm) ENVIRONMENTAL Storage Temperature: -45° to 85°C (-49 to 185º F) Operating Temperature: -5° to 55°C (23 to 131º F) Operating Humidity: 0% to 95%, non-condensing Operating Altitude: Up to 13,000 feet (3.96 km) STANDARDS Meets UL, telcordia (Bellcore), neC 2002, CSA, neBS Level 3, ieC, and Ce standards Lifetime WARRANTY 15 years 1 Important Note: the fuse manufacturer recommends that fuses be continuously operated at no more than 80% of their nominal current rating. w w w. a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1 8 ® 10/09 • 105203AE PowerWorx Power Distribution Products ® PowerWorx Uninterrupted Power GMt Series Front view rear view Each side (BUS) must be able to handle load if A or B is lost. (i.e. 30 amps or 60 total per side) Standard 10/10-Position Dual rear Power Feed Sample Catalog number: PWX-001rGCSD10PWDP Ordering Information Uninterrupted Power GMT Series Standard front and rear access fuse panels Shipping Catalog Number • Dual power feed, 10/10 position fuse configuration • Wire-wrap alarm contact connection • See color options below • Putty white Quick Ship PWX-011rGCSD10PWDP • Black Standard PWX-011rGCSD10PWDB note: Panels ship with dummy fuses installed in all positions, one designation card holder and card, one voltage designation label, two 2-hole lugs per power bus, two ring lugs (for grounding), and one designation pin holder per fuse holder. w w w. a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1 9 ® 10/09 • 105203AE PowerWorx Power Distribution Products ® PowerWorx ™ SuperPower GMt Series PowerWorx SuperPower GMt Series panels accept high input power – up to 100 Amps per bus – with up to 20 Amps output power per GMt fuse position. Standard (front and rear access) and total-front- access panels are available. User-friendly “upside down” fuse holders and high-brilliance LeDs allow technicians to quickly identify and replace blown fuses in the field. other features include two-post grounding, removable clear polycarbonate input/output connector covers, and a selection of connector and fuse configurations. these panels operate under either positive or negative voltage conditions. w w w. a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1 10 ® 10/09 • 105203AE PowerWorx Power Distribution Products ® PowerWorx ™ SuperPower GMt Series Specifications PHYSICAL Dimensions (HxWxD) Standard access: 1.75" x 17.12" x 8" (44 x 435 x 203 mm) total-front-access: 3.5" x 21.25" x 4" (89 x 540 x 102 mm) Dimensions do not include depth of power connectors, alarm lamps or fuses. Weight: Approximately 10 lbs (4.5 kg) Rack Mounting Width: Standard Access and PWX-n01FGCSD10PSPD: 19" or 23" (483 or 584 mm) flush or recess-mountable with universal mounting brackets. eiA/WeCo or etSi mounting options available total-front-access: 23" (584 mm) flush or recess-mountable into eiA and WeCo racks Housing Material: Cold-rolled 16 gauge steel. Polycarbonate protective cover provided with all panels Housing Finish: Putty white powder-coat POWER 1 Fuse Capacity : 0.2 to 20 Amps Panel Capacity: 100 Amps maximum per bus (200 Amps total) Operating Voltage: ±24 vdc (-21 to -30 vdc tolerance) or ±48 vdc (42 to 56 vdc tolerance) Power Dissipation: 100 watts maximum Fail Alarm Indicators: red LeD indicates blown fuse. Green LeD indicates power on Alarm Contact Connection: Wire-wrap connections. Alarm output contacts provided for audible, visual and remote alarms Alarm Contact Relay: 1 Amp maximum Input Feed Connection: two-hole compression-lug (stud-type) accepts range of wire up to 2 AWG. Panel ships with two 2-hole lugs (accepting 2 AWG stranded wire) per power bus. Output Feed Connection: Screw-down barrier terminal strip accepts range of wire up to 12 AWG. Grounding: two-post grounding accepts range of wire up to #10 AWG for single connection; two-hole compression lug (stud-type) accepts wire up to #2 AWG. Fuse Output Max. Amperage Range Of Bare Post/ Distance Between Configuration Connector Type Per Fuse Position Wire Accepted Stud Size Barriers Walls D10 Screw-Down 20 Amps 12-22 AWG #6-32 0.325" (8.255 mm) D20 Screw-Down 10-15 Amps 16-30 AWG #3-48 0.20" (5.08 mm) ENVIRONMENTAL Storage Temperature: -45° to 85°C (-49 to 185º F) Operating Temperature: -40° to 65°C (40 to 149º F) Operating Humidity: 0% to 95%, non-condensing Operating Altitude: Up to 13,000 feet (3.96 km) STANDARDS Meets UL, telcordia (Bellcore), neC 2002, CSA, neBS Level 3, ieC, and Ce standards WARRANTY 15 years 1 Important Note: the fuse manufacturer recommends that fuses be continuously operated at no more than 80% of their nominal current rating. w w w. a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1 11 ® 10/09 • 105203AE PowerWorx Power Distribution Products ® PowerWorx ™ SuperPower GMt Series Front view CAUTION�RTN A BATT�BATT A HOT SURFACE�15�GND�AMP��A� MAX�1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10� FUSE RTN� �FUSE�POWER A� ALARM�MAX�INPUT�100A� ��� BATT� GND ALARM 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10�B� GND GND BATT B RT�N�RTN B rear view FUSE�POWER B��ALARM� Dual Power Feed 10/10-Position PWX-031rXCSD10PWDP Front view CAUTION�BATT�RTN A BATT A HOT SURFACE�15�GND��A� AMP� MAX��1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 FUSE RTN� FUSE�POWER A�� ALARM� MAX�INPUT�100A� ��� BATT� GND 1 2 3 4 5 6 7 8 9 10 ALARM 1 2 3 4 5 6 7 8 9 10�B� �GND GND BATT B rear view RTN�RTN B FUSE�POWER B��ALARM� Dual Power Feed 20/20-Position PWX-031rGCSD20PWDP CAUtion rtn A BAtt A 15 Hot SUrFACe BAtt GnD AMP 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 A MAX FUSe rtn Per PoWer A 1 6 10 ALArM FUSe MAX inPUt 100A GnD BAtt 1 2 3 4 5 6 7 8 9 10 ALArM 1 2 3 4 5 6 7 8 9 10 B GnD GnD BAtt B FUSe PoWer B rtn B 1 6 10 ALArM rtn Front view total-Front-Access Dual Power Feed 10/10-Position PWX-031FGCSD10PWDP w w w. a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1 12 ® 10/09 • 105203AE PowerWorx Power Distribution Products ® PowerWorx ™ SuperPower GMt Series Ordering Information SuperPower GMT Series Standard front and rear access fuse panels Shipping Catalog Number Dual power feed, 10/10 position fuse configuration Wire-wrap alarm contact connection Putty white 20 Amp max per fuse Quick Ship PWX-031rXCSD10PWDP Dual power feed, 20/20 position fuse configuration Wire-wrap alarm contact connection Putty white 10 Amp max per fuse Standard PWX-031rGCSD20PWDP 15 Amp max per fuse Standard PWX-031rDCSD20PWDP Total front access fuse panels Dual power feed, 10/10 position fuse configuration Wire-wrap alarm contact connection Putty white 20 Amp max per fuse Standard PWX-031FXCSD10PWDP 15 Amp max per fuse Standard PWX-031FGCSD10PWDP Dual Power feed, 20/20 position fuse configuration Wire-wrap alarm contact connection Putty white 10 Amp max per fuse Standard PWX-031FGCSD20PWDP note: Panels ship with dummy fuses installed in all positions, one fused equipment designation card holder and cards, one voltage designation label, two 2-hole lugs per power bus (accepts 2 AWG stranded wire), two ring lugs (for grounding), and four sheets of perforated fuse designation cards and six plastic covers. w w w. a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1 13 ® 10/09 • 105203AE PowerWorx Power Distribution Products ® PowerWorx ™ Select Series As data and telephony converge, network elements with varying amperage requirements are often mixed within the same bay. the Select Series fuse platform enables service providers to fuse this equipment from one platform, in a single rack unit, making the most of valuable space. its compact footprint and versatility are well-suited for collocation applications where high-amperage equipment such as routers, DSLAMs, and Sonet gear is installed with lower-amperage equipment. its patent- pending modular design enables service providers to combine tPA, KtK/KLM, tPM or GMt fuses within a single rack unit. input power up to 100 Amps per bus with up to 50 Amps output power per fuse position is available. w w w. a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1 14 ® 10/09 • 105203AE PowerWorx Power Distribution Products ® PowerWorx ™ Select Series Specifications PHYSICAL Dimensions (HxWxD) 1.75" x 17.12" x 10" (44 x 435 x 254 mm). Dimensions do not include depth of power connectors, alarm lamps, or fuses. Weight: Approximately 12.5 lbs (5.7 kg) Rack Mounting Width: the standard front/rear access fuse panel can be flush- or recess-mounted into 19-inch (483 mm) or 23-inch (584 mm) eiA and WeCo racks. etSi mounting is also available. Housing Material: Cold-rolled 16 gauge steel. Polycarbonate protective cover provided with all panels Housing Finish: Powder-coat putty white POWER Fuse Capacity: the fuse manufacturer recommends that GMt fuses rated 8 to 15 Amps be continuously operated at no more than 80% of their nominal current rating. TPA Fuses: 3 to 50 Amps 1 KLM/KTK Fuses: 5 to 30 Amps GMT Fuses: 0.2 to 15 Amps G4 configurations accept fuses rated up to 15 Amps. G1 configurations accept fuses rated up to 10 Amps. Panel Capacity: 100 Amps maximum per bus (200 Amps total, dual bus configuration) Operating Voltage: -24 vdc (-21 to -30 vdc tolerance) or -48 vdc (-42 to -56 vdc tolerance) Power Dissipation: 100 watts maximum Fail Alarm Indicators: red LeD indicates blown fuse. Green LeD indicates power on. Alarm output contacts provided for audible, visual, and remote alarms. Alarm Contact Connection: Wire-wrap or screw-down barrier terminal strip Alarm Contact Relay: 1 Amp maximum Input Feed Connection: two-hole compression lug (stud-type) accepts range of wire up to 2 AWG. Product ships with two 2-hole lugs (accepting 2 AWG wire) per power bus, plus one extra 2-hole lug. Output Feed Connection: Screw-down barrier terminal strip accepts range of bare wire up to 8 AWG (tPA), 10 AWG (KLM), or 12-16 AWG (GMt). Grounding: two-post grounding accepts range of wire up to #10 AWG for single connection; two-hole compression lug (stud-type) accepts wire up to #2 AWG. Fuse Type Bare Wire Size Ring Lug Size Post Distance Between Size Barrier Walls tPA 8-16 AWG 8 AWG 8-32 0.378" (10 mm) KLM/KtK1 8-16 AWG 10 AWG 8-32 0.320" (8 mm) GMt, 4 12-22 AWG 12 AWG 6-32 0.325" (8 mm) GMt, 5 and 10 position 14-22 AWG 14 AWG 6-32 0.260" (7 mm) 2 GMt, 10 position 16-30 AWG 16 AWG 3-48 0.200" (5 mm) (A4 G1 combination) ENVIRONMENTAL Storage Temperature: -45° to 85°C (-49 to 185º F) Operating Temperature: -5° to 55°C (23 to 131º F) Operating Humidity: 0% to 95%, non-condensing Operating Altitude: Up to 13,000 feet (3.96 km) STANDARDS Meets UL, telcordia (Bellcore), neC 2002, CSA, neBS Level 3, ieC, and Ce standards WARRANTY 15 years 1 KtK fuses are not currently rated for DC voltages by Underwriters Laboratories (UL). KtK fuses will fit in the KLM fuse holder. w w w. a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1 15 ® 10/09 • 105203AE PowerWorx Power Distribution Products ® PowerWorx ™ Select Series Front view rear view 4tPA/10 GMt PWX-041rCA4GiySPWP Front view rear view 4tPA PWX-041rCA4XXySPWP Front view rear view 4 tPA/4GMt PWX-041rCA4G4ySPWP w w w. a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1 16 ® 10/09 • 105203AE PowerWorx Power Distribution Products ® PowerWorx ™ Select Series Front view rear view 4KLM/4GMt PWX-041rCK4G4ySPWP Front view rear view 4KLM PWX-041rCK4XXySPWP Ordering Information Select Series Standard front access fuse panel Shipping Catalog Number Dual power feed Wire-wrap alarm contact connection Putty white See fuse configuration options below Quick Ship 4 KLM/4 GMt PWX-041rCK4G4ySPWP 4 tPA/4 GMt Quick Ship PWX-041rCA4G4ySPWP 4 tPA/10 GMt Standard PWX-041rCA4G1ySPWP 4 tPA Standard PWX-041rCA4XXySPWP 4 KLM Standard PWX-041rCK4XXySPWP note: Panels ship with dummy fuses installed in all GMt and KLM fuse positions, one designation card holder and card, one voltage designation label, two 2-hole lugs per input power bus, and two ring lugs (for grounding). other custom configurations available. For more information call ADC at 1-800-366-3891 w w w. a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1 17 ® 10/09 • 105203AE PowerWorx Power Distribution Products ® PowerWorx Select Series with Low voltage Disconnect the PowerWorx Low voltage Disconnect (LvD) fuse panel provides power distribution, protection and LvD functionality in a single chassis. the modular panel offers high-density capabilities and integrated functionality in a small, two-inch (height) panel. And the low voltage disconnect device disconnects at 39 volts DC and reconnects at 47 volts DC, protecting battery and network equipment life. the panel requires a 23-inch rack for proper mounting. w w w. a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1 18 ® 10/09 • 105203AE PowerWorx Power Distribution Products ® PowerWorx Select Series with Low voltage Disconnect Specifications Panel Bus Capacity TPA: 75 Amps per input connector - 4 Bus per panel, two connectors per bus/side, 300 Amps total GMT: 65 Amps per input connector - 2 Bus per panel, one connector per bus/side, 130 Amps total GMT/TPA: 75 Amps per input connector - 2 Bus per panel, one connector per bus/side, 150 Amps total Panel Fuse Capacity TPA: 50 Amps maximum GMT: 2/10 Amps to 15 Amps per fuse Input Voltage Range: -48 vdc (-39 to -60 vdc tolerance); -48 minimum Low Voltage Disconnect Range: Disconnect at 39 volts DC; reconnect at 47 volts DC Input Terminal Connections: two-hole compression lug (stud-type) – Accepts up to 2 AWG stranded wire Output Terminal Connections: Screw-down barrier terminal strip Visual Alarms: red LeD (LvD alarm), red LeD (fuse alarm) and Green LeD (power on) Alarm Contact Relay: 1 Amp maximum Alarm Contact Connections: Wire-wrap Chassis Ground Connections: two-post grounding accepts range of wire up to #10 AWG for single connection; two-hole compression lug (stud-type) accepts wire up to #2 AWG. Mounting: 23" eiA/WeCo Standard Dimensions: 11" deep (with cover) x 2" high Chassis Material: Cold rolled steel Color: Putty white Finish: Powder paint Rear Cover: Snap-in covers for in/out connectors Ship Along Items: rack mounting screws, ground lugs, mounting brackets and screws, pressure-sensitive designation cardholder and card Standards: UL, neBS L3, neC 2002, CSA, Ce, telcordia (Bellcore) Warranty: 5 years 11.03" 11.03" (280 mm) (280 mm) 23.0" 23.0" 22.31" (584 mm) 22.31" (584 mm) (567 mm) (567 mm) 1.97" 1.13" 1.13" 1.97" (50 mm) (29 mm) (29 mm) (50 mm) 21.13" 21.13" (54 mm) (54 mm) PWX-F01RBG10YSPHP (GMT) PWX-F41RBA4XXYSPHP (TPA) * if battery voltage falls below 20 vdc, LvD feature is disabled (contactor closes) due to nC (normally closed) contactor of LvD circuit. 11.03" (280 mm) 23.0" 22.31" (584 mm) 1.13" (567 mm) 1.97" (29 mm) (50 mm) 21.13" (54 mm) PWX-F41RDA4XXYSPHP (TPA/GMT) w w w. a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1 19 ® 10/09 • 105203AE PowerWorx Power Distribution Products ® PowerWorx Select Series with Low voltage Disconnect Front view rear view iSo view Ordering Information PowerWorx Select Series Low voltage disconnect (LVD) fuse panel Shipping Catalog Number 4/4-position tPA, dual power feed, LvD Quick Ship PWX-F41rBA4XXySPHP 4/4-position tPA, dual power feed, LvD with or-ing diodes Standard PWX-F41rDA4XXySPHP 10/10-position GMt, single power feed, LvD Standard PWX-F01rBG10ySPHP 2/2-position tPA and 5/5 position GMt Standard PWX-F41rBA2G5ySPHP w w w. a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1 20 ® 10/09 • 105203AE PowerWorx Power Distribution Products ® PowerWorx Modular Front Access Power Distribution Panel ADC introduces a fully modular Power Distribution Panel that can support up to 4 GMt modules (8 GMt Fuses per bus A and B) or 2 tPA modules (4 tPA Fuses per bus A and B). this panel is known for high-quality and high-performance. ADC has innovated new ways to add flexibility and provide features for demanding applications with this new panel. Features: • All Front Access • Alarms − All input and output connections (including − each module is equipped with 3 LeD indicators: remote alarm terminals) and fusing is accessible LvD Power, Fuse from the front of the chassis. x Power yeLLoW = -24vdc MoDe, • Fully Modular Design Green = +48vdc MoDe − Chassis support 2 tPA modules, or 4 GMt − the LvD system will not activate until the power Modules or 1 tPA and 2 GMt modules. LeD is on. − Modules can be added as required. − each module is also connected with a central alarm module via the chassis backplane. − Modules can be removed without having to disconnect the bus (A1, A2, B1, and B2) inputs. • Central Alarm Module − Power modules are hot-swappable. − Located in the central of the chassis, this module provides… • input voltage Selection x two sets of external alarm contracts − the PDU can be used in -24vdc or -48vdc (nC/C/no). applications. x Central LeD indicator. − Since the panel is bus partitioned, half of the chassis (A1, A2 side) can be used to distribute -24vdc and the other half (B1, B2 side) can be used to distribute -48vdc. • Solid State Low voltage Disconnect (LvD) − the LvD system uses solid state switches instead of electromechanical contactors. − the LvD recovery system has variable settings for the -48vdc mode. − the LvD recovery for the -24vdc mode is -23 ±0.5vdc. − Compares with tP-76450 battery separation requirements. w w w. a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1 21 ® 10/09 • 105203AE PowerWorx Power Distribution Products ® PowerWorx Modular Front Access Power Distribution Panel Applications: • Central office, Multimedia H.e., remote terminal, DSLAM’s, MUX’s, routers, servers and switches Compliances: All power distribution panels and components shall • Bellcore Gr-1089-Core, electromagnetic comply with the requirements of the following Compatibility and electrical Safety standards documents: • Underwriters Laboratory (UL) • Bellcore tr-nWt-000928, Generic • Ce (for international markets) requirements for rack Mountable Fuse Panels • neBS (issue 1, 1990) • eU roHS Directive 2002/95/eC-roHS • Bellcore tr-tSy-000799, telecommunications Fuses • tP-76450 battery separation with LvD requirements • Bellcore Gr-63-Core, neBS requirements: Physical Protection Specifications PHYSICAL Dimensions (HxWxD): 3.47 x 19.35 x 11.55 inches (88 x 491 x 293 mm) Color: Putty white Rack mounting: 23-inch (555 mm) WeCo or etSi ELECTRICAL Operating voltages: –48 vdc (normal), –30 to –56 vdc tolerance Input current: 75 Amps per bus maximum Fuse type: tPA, GMt Maximum fuse size GMT model: 20 Amps per fuse, 75 Amps total per GMt module TPA model: 50 Amps per fuse, 75 Amps total per each pair of tPA fuses (e.g., A1-1, A1-2) Input terminal type: 2-hole compression lug (0.25 inch holes on 0.625 inch centers), Max lug width 0.620 inches Output terminal type: Screw down terminal (8-32), Max. lug width 0.42 inches Grounding connections: two 1/4-inch studs on 0.625 centers ENVIRONMENTAL Operating temperature: –5º to +55º C (23 to 131º F) Up to 65º C (149º F) with airflow of 220 CFM or greater Storage temperature: –45º to +85º C (-49 to 185º F) Humidity range: 0% to 95% humidity, no condensation Altitude range: Up to 13,000 ft. (3.96 km) Acoustic noise: 0 dBA above ambient Heat dissipation (fully loaded): 40 watts max., With all four buses at full load WARRANTY 5 years w w w. a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1 22 ® 10/09 • 105203AE PowerWorx Power Distribution Products ® PowerWorx Modular Front Access Power Distribution Panel Front view rear view 8GMt PWX-1AFG4DA Front view rear view 4tPA PWX-1AFA2DA Ordering Information Modular front access power distribution panel GMT TPA Low Voltage Positions Positions Alarm Disconnect OR-ing Catalog Number 16 - X X PWX-1LFG4DA 8 - X X PWX-1LFG2DA 16 - X X X PWX-1AFG4DA 8 - X X X PWX-1AFG2DA 16 - X PWX-1LFG4AA 8 - X PWX-1LFG2AA 4 - X PWX-1LFG1AA - 8 X X PWX-1LFA2DA - 8 X X X PWX-1AFA2DA - 8 X PWX-1LFA2AA - 8 X X PWX-1AFA2AA 8 4 X X X PWX-1AFM2DA other custom configurations available. For more information call ADC at 1-800-366-3891 w w w. a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1 23 ® 10/09 • 105203AE PowerWorx Power Distribution Products ® PowerWorx ™ Select Series Circuit Breaker now you can order any combination of ADC’s PowerWorx Select Series circuit breaker platform configurations—up to 10 panels per configuration. the Select Series circuit breaker platform can be configured-to-order to meet unique network powering needs. Select from various single or double pole hydraulic magnetic circuit breaker types and alarm connectors. Circuit breaker amperages can be mixed within a single panel, allowing maximum flexibility. the Select Series circuit breaker platform accepts input power up to 100 Amps per bus, and up to 50 Amps per breaker output position. Hydraulic magnetic circuit breakers provide precise and reliable powering control. the breakers can be quickly reset to restore power, have customizable trip points (in amperes), and time delays (in seconds). High-brilliance LeDs allow technicians to quickly identify input power failures or tripped breakers. other features include two-post grounding and separate removable inPUt/oUtPUt protector covers. these panels operate under either positive or negative voltage conditions. w w w. a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1 24 ® 10/09 • 105203AE PowerWorx Power Distribution Products ® PowerWorx ™ Select Series Circuit Breaker Specifications PHYSICAL Dimensions (HxWxD): 1.75" x 17.12" x 10" (44 x 435 x 254 mm). Dimensions do not include depth of power connectors, alarm LeDs, or circuit breakers. Weight: Approximately 13 lbs (4.9 kg) Rack Mounting Width: 19" or 23" (483 or 584 mm) recess-mountable mounting brackets. WeCo/eiA rack-mountable. Housing Material: Cold-rolled 16 gauge steel. Protective input and output covers provided with all panels. Housing Finish: Powder-coat putty white POWER Time Delays: Short 10000 CURVE 32: D.C., 50/60 Hz 1000 100 10 1 -1 .01 .001 100 200 300 400 500 600 700 800 900 1000 1100 1200 135 150 PERCENT OF RATED CURRENT Percent of Rated Current Trip Time Delay 100% 135% 150% 200% 400% 600% 800% 1000% 1200% (Seconds) 32 (short) no triP 300-7.00 200-5.00 100-2.00 030-.500 008-.300 006-.150 .005-.100 005-.100 Breaker Type: Hydraulic magnetic circuit breaker Actuator: rocker with finger guard (breaker amperage shown on faceplate) Trip: Series trip with manual reset Panel Capacity: 100 Amps maximum per bus (200 Amps total, dual bus configuration) Operating Voltage: ±24 vdc (-21 to -30 vdc tolerance) or ±48 vdc (42 to 56 vdc tolerance) Power Dissipation: 80 watts maximum Fail Alarm Indicators: red LeD indicates tripped breaker. Green LeD indicates power on. Alarm output contacts provided for audible, visual, and remote alarms. Alarm Contact Connection: Wirewrap or screw-down barrier terminal strip Alarm Contact Relay: 1 Amp maximum Input Power Feed Connection: two-hole compression lug (stud-type) accepts range of wire up to 2 AWG. Product ships with two 2-hole lugs (accepting 2 AWG wire) per power bus Output Power Feed Connection: Screw-down barrier terminal strip accepts range of bare wire for 8-16 AWG. Post Size: 8-32 Distance Between Barrier Walls: 0.378" (9.60 mm) Grounding: two-post grounding accepts range of wire up to 10 AWG. Grounding can be done with two #10 wires and two #10 ring terminals or use larger AWG sizes across both studs. ENVIRONMENTAL Storage Temperature: -40° to +85°C (40 to 185º F) Operating Temperature: -40° to +65°C (40 to 149º F) Operating Humidity: 0% to 95%, non-condensing Operating Altitude: Up to 13,000 feet (3.96 km) STANDARDS Meets UL, telcordia (Bellcore), neC 2002, CSA, neBS Level 3, and Ce standards WARRANTY 5 years w w w. a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1 25 ® 10/09 • 105203AE PowerWorx Power Distribution Products TRIP TIME IN SECONDS ® PowerWorx ™ Select Series Circuit Breaker 5A 5A 5A 5A 5A 5A 5A 5A 5A 5A 5A 5A 5A 5A 5A 5A Front view rear view 8/8-Position Dual Power Feed, Short Delay Breakers PWX-45nnnnnnnnSWP PWX-351NNNNNNNNSWP 10A 20A 5A 1A 10A 20A 5A 1A Front view rear view 4/4-Position Dual Power Feed, Short Delay Breakers PWX-451vMnHXXXXSSP Front view PWX-451VMNHXXXXSSP rear view 7/7-Position Dual Power Feed, Short Delay Breakers PWX-451nMHHHtG2SWP w w w. a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1 26 ® 10/09 • 105203AE PowerWorx Power Distribution Products ® PowerWorx ™ Select Series Circuit Breaker Catalog Number PWX- __ 4 51 __ __ __ __ __ __ __ __ S __ P Delay 4 Short delay 1 Circuit Breaker Amperage Panel Color Quantity P Putty White Poles Amp H 1 1 Alarm Contact Connection t 1 3 W Wire-wrap n 1 5 S Screw-down barrier terminal strip v 1 10 A 1 15 Output M 1 20 S Screw-down J 1 22 1 Select various amperage values. Maximum of 100 Amps per side. Modules are installed left to right. the same amperage F2 2 25 values will be duplicated on the opposite side. All blank L2 2 26 spaces in the catalog number ordering scheme must contain S2 2 30 a value. Please fill in unused blank spaces with an “X.” D2 2 36 r2 2 40 G2 2 50 X n/A BLAnK note: Panels ship with one designation card holder and card, one voltage designation label, two 2-hole lugs per input power bus, two ring lugs (for grounding), and rack mounting brackets. w w w. a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1 27 ® 10/09 • 105203AE PowerWorx Power Distribution Products ® PowerWorx ™ Advantage Series the Advantage Series platform accepts input power up to 300 Amps per bus (600 Amps total capabilty), up to 125 Amps per high-current output position, and up to 15 Amps per GMt fuse position (optional). A patent-pending design, the Advantage Series platform can be configured to meet unique network powering needs. Select from various input power cable routing types, fusing options and alarm connectors. industry standard “bullet” terminal breakers or fuses can be mixed within a single panel, allowing maximum flexibility. Compact, flexible PowerWorx configurations suit most network applications. Using the universal mounting brackets, the panel can be flush- or recess-mounted into 19-inch (483 mm) and 23-inch (584 mm) eiA and WeCo racks. All Advantage Series panels have six positions on each side. each position can be filled with either circuit breakers, tPC Fuses or both. tPC up to 125 Amps per position. Circuit breakers up to 100 Amps per position. w w w. a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1 28 ® 10/09 • 105203AE PowerWorx Power Distribution Products ® PowerWorx ™ Advantage Series Specifications PHYSICAL Dimensions (HxWxD): 5.25" x 17.12" x 8.89" (133 mm x 435 mm x 226 mm) Dimensions do not include depth of power connectors, alarm lamps, or fuses Weight: Approximately 25 lbs (without breakers or fuses) Rack Mounting Width: Using the universal mounting brackets, the standard front/rear access fuse panel can be flush- or recess-mounted into 19-inch (483 mm) and 23-inch (584 mm) eiA and WeCo racks POWER Breaker/Fuse Capacity High Current Breakers/Fuses: 1 to 125 Amps Works With: Carling technologies, eaton, Airpax Circuit Breakers; Bussman tPC fuse types GMT Fuses: 0.2 to 15 Amps Panel Capacity: 300 Amps maximum per bus (600 Amps total, dual bus configuration) Operating Voltage: -48 vdc (-42 to –56 vdc tolerance) Power Dissipation: 50 Watts maximum Fail Alarm Indicators: Flashing red LeD indicates tripped breaker or blown fuse. Green LeD indicates power on. Alarm output contacts provided for audible, visual, and remote alarms. Alarm Contact Connection: Screw-down barrier terminal strip Alarm Contact Relay: 1 Amp maximum Grounding: two-post grounding accepts range of wire up to 2 AWG (Flex) or 1 AWG (Stranded) Input Feed Connection: two-hole compression lug (stud-type) accepts range of cable up to 350 MCM (stranded) Output Feed Connection: two-hole compression lug (stud-type) accepts range of wire up to 2 AWG (flex) or 1 AWG (stranded) Connector Type Bare Cable/Lug Stud Screw Center Distance Between Wire Size Size Size to Center Barriers Input Terminals Up to 350 MCM 3/8" 3/8"-16 1" 1.3" (Stranded) High Current Up to 1AWG (Stranded) 1/4" 1/4"-20 .625” .72" Output Terminals 2 AWG (Flex) (5/8") GMT Output Terminals 14-22 AWG n/A M3.5 .374" .318" Alarm Terminals 16-30 AWG n/A 3-48 .250" .200" (screw down) Ground Terminals Up to 1 AWG (Stranded) 1/4" 1/4"-20 .625" n/A (two sets) 2 AWG (Flex) (5/8") STANDARDS Meets UL, telcordia (Bellcore), neC 2002, CSA, neBS Level 3, ieC, and Ce Standards w w w. a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1 29 ® 10/09 • 105203AE PowerWorx Power Distribution Products ® PowerWorx ™ Advantage Series rear view Front view 4 GMt positions per side PWX-061rD6yStSP rear view Front view no GMt Fuses PWX-061rD6nXXSP-C w w w. a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1 30 ® 10/09 • 105203AE PowerWorx Power Distribution Products ® PowerWorx ™ Advantage Series Ordering Information Advantage series Fuse/breaker panels Shipping Catalog Number Dual bus with six positions per bus Screw-down alarm terminal type Putty white Features 4GMt positions per side and screw-down GMt Quick Ship PWX-061rD6yStSP output connectors. input cabling is top-down with GMt fuses. no GMt fuses for output or input. Standard PWX-061rD6nXXSP-C note: Depending on preference for fuses or breakers, either fingerguards or tPC fuse holders need to be ordered with each panel. Designation cards available see page 36. w w w. a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1 31 ® 10/09 • 105203AE PowerWorx Power Distribution Products ® PowerWorx GMt 60e Series An economical Alternative As networks and the variety of powered network devices grow, so does the need for reliable power distribution and protection in multimedia broadband networks. ADC's PowerWorx has been engineered from the ground up to properly protect and distribute power to valuable, revenue-generating network equipment. PowerWorx GMt 60e Series panels set a new standard – delivering the power and the protection that service providers need. So if your network needs power that works, use PowerWorx. PowerWorx GMt 60e Series fuse panels deliver power to valuable, revenue-generating network equipment located in broadband multiservice networks. the GMt 60e Series accepts input power up to 60 Amps per bus. Up to 15 Amps per fuse position is standard. PowerWorx panels are independently tested to comply with the industry's highest standards, including Ce, UL, CSA, and neC 2002. in addition, the GMt 60e Series is backed by a five-year warranty. Flexible PowerWorx configurations suit most every network application. Panels can be mounted into 19-inch (483 mm), 23-inch (584 mm), electronic industries Association (eiA) or Western electric Company (WeCo), and 600 mm racks. User-friendly ”upside down“ fuse holders and high-brilliance LeDs allow technicians to quickly identify input power failure and blown fuse alarms. w w w. a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1 32 ® 10/09 • 105203AE PowerWorx Power Distribution Products ® PowerWorx GMt 60e Series Specifications STANDARDS Meets UL, neC 2002, CSA, and Ce standards PHYSICAL Dimensions (HxWxD): Standard Access: 1.75" x 17.12" x 3.0" (44 mm x 435 mm x 76.2 mm) Dimensions do not include depth of power connectors, alarm lamps or fuses. Weight: Approximately 4 lbs (1.8 kg) Rack Mounting Width: 19" (483 mm) WeCo (2")/eiA (1.75") rack unit spacing Flush mounting 23" (584 mm) and 600 mm rack extenders also available Rack Unit Spacing: WeCo (2")/eiA (1.75") Housing Material: Cold-rolled 16 gauge steel Housing Finish: Putty white powder-coat POWER Fuse Capacity*: 0.2 to 15 Amps Panel Capacity: 60 Amps (maximum) per bus Operating Voltage: -48 vdc (-42 to -56 vdc tolerance) Power Dissipation: 12W maximum per bus Fail Alarm Indicators: red LeD indicates blown fuse. Green LeD indicates power on. Alarm output contacts provided for audible, visual and remote alarms (optional). Alarm Contact Connection: Set-screw barrel terminal strip accepts range of wire up to 12 AWG (3.3 mm) Alarm Contact Relay: 1 Amp maximum Input Feed Connection: Set-screw barrel connector accepts range of wire up to 6 AWG (13.3 mm). Stud-type (accepting two-hole compression lug) accepts range of wire up to 2 AWG (33.6 mm). Distance between barrier walls (stud-type) .62" (15.8 mm). Stud size .25" (6.35 mm) center to center spacing of studs .625" (15.88 mm). Output Feed Connection: Set-screw barrel terminal strip accepts range of wire up to 12 AWG (3.3 mm) Grounding: Single-post grounding accepts range of wire up to 10 AWG (5.2 mm) ENVIRONMENTAL Storage Temperature: -45° to 85°C (-49 to 185º F) Operating Temperature: -5° to 55°C (23 to 131º F) Operating Humidity: 0% to 95%, non-condensing Operating Altitude: Up to 13,000 feet (3.96 km) WARRANTY Five years Panels ship with one fused-equipment designation card holder and card and one ring lug (for grounding). * important note: the fuse manufacturer recommends that GMt fuses rated 8 to 15 Amps be continuously operated at no more than 80% of their nominal current rating. w w w. a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1 33 ® 10/09 • 105203AE PowerWorx Power Distribution Products ® PowerWorx GMt 60e Series Ordering Information GMT 60e Series Standard front and rear access fuse panels Shipping Catalog Number Dual Power feed, 10/10 position fuse configuration Standard eWX-001rGSBD10XeP Set-screw barrel input connector no alarm output Putty white Dual Power feed, 10/10 position fuse configuration Standard eWX-001rGSBD10BeP Set-screw barrel input connector Wire-wrap alarm contact connection Putty white Dual Power feed, 10/10 position fuse configuration Standard eWX-001rGCBD10BeP Stud-type powering input Wire-wrap alarm contact connection Putty white w w w. a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1 34 ® 10/09 • 105203AE PowerWorx Power Distribution Products ® PowerWorx DSX PDP Series Primarily used to power LeDs in DSX modules, the PDP Series is also used to power auxiliary equipment such as intraoffice and bridging repeaters as well as communication panels. Features two-hole compression lug-style power input terminals, field-replaceable, high brilliance red LeDs to ensure panel uptime and enhanced fuse visibility with "upside down" installed GMt fuse holders. Panel is compliant with neBS Level 3, UL, neC 1999 and CSA. electrical Specifications Input power: -42 to -56 vdc (no strapping required) Bus amperage: 60 Amps maximum per bus Remote alarm contact (resistive load): 125v maximum Local alarm indicator: LeD GMT Fuses: 3 Amps maximum per fuse 20-Position Fuse Panel Ordering Information DSX PDP series Standard front and rear access fuse panels Shipping Catalog Number Single power feed 20 position fuse configuration 3 Amp max per fuse Wire-wrap alarm contact connection Putty white Quick Ship PDP-FPCS201PWWXX Black Standard PDP-FPCS201BWWXX w w w. a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1 35 ® 10/09 • 105203AE PowerWorx Power Distribution Products ® PowerWorx Accessories Cable Management Bars For Standard (Front and rear Access) Fuse Panels Ordering Information Cable management bar Catalog Number Putty white - 19" CMB-P-19 Putty white - 23" CMB-P-23 Compression Lugs For two-Hole Stud-type input Power Connections Compression lugs provide a robust and reliable electro-mechanical connection. Ordering Information Compression lug; ships two per pack Catalog Number 2 AWG CL-02M 4 AWG CL-04M 6 AWG CL-06M 14 AWG CL-14M Designation Card Holder and Cards Designation cards held in pressure-sensitive card holder enable easy identification and location of fused equipment. Ordering Information Designation card holder kit Includes: Catalog Number 1 plastic designation card holder, DCK-02 2 designation cards and window w w w. a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1 36 ® 10/09 • 105203AE PowerWorx Power Distribution Products ® PowerWorx Accessories GMt Fuses/Fuse Designation Pins – Alarm indicator Ordering Information GMT fuses/fuse designation pins - alarm indicator Color of Indicator/ Fuse Catalog Pin Catalog Fuse Size Designation Pin Number Number 2/10 Amps Black-red F-2/10 P-2/10 1/4 Amps violet F-1/4 P-1/4 3/8 Amps White-Green F-3/8 P-3/8 1/2 Amps red F-1/2 P-1/2 3/4 Amps Brown F-3/4 P-3/4 1 Amps Gray F-1 P-1 1-1/3 Amps White F-1 1/3 P-1 1/3 1-1/2 Amps White-yellow F-1 1/2 P-1 1/2 2 Amps orange F-2 P-2 2-1/2 Amps orange-White F-2 1/2 P-2 1/2 3 Amps Blue F-3 P-3 3-1/2 Amps White-Blue F-3 1/2 P-3 1/2 4 Amps White-Brown F-4 P-4 5 Amps Green F-5 P-5 7-1/2 Amps Black-White F-7 1/2 P-7 1/2 10 Amps red-White F-10 P-10 12 Amps yellow-Green F-12 P-12 15 Amps red-Blue F-15 P-15 Dummy GMt GMt Dummy 20 Amps F-20 GMt Designation Pin Holder GMt designation pin holder securely holds designation pins for improved fuse value identification. Ordering Information GMT designation pin holder Catalog Number Holds up to ten fuse designation pins, DPK-01 adhesive back allows for quick and easy mounting (ships two per pack) GMt Fuse Puller the compact puller grips firmly to remove GMt fuses. Ordering Information GMT fuse puller Catalog Number Fuse puller; ships two per pack FP-G w w w. a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1 37 ® 10/09 • 105203AE PowerWorx Power Distribution Products ® PowerWorx Accessories 1 KLM Fuses – non-indicator the compact puller grips firmly to remove GMt fuses. Ordering Information KLM fuses - non-indicator Catalog Number 5 Amps KLM-05 10 Amps KLM-10 15 Amps KLM-15 20 Amps KLM-20 25 Amps KLM-25 30 Amps KLM-30 KLM Dummy KLM Dummy 1 All KLM fuse modules house a fuse alarm indicating red LeD. KLM Fuse Panel Cap Ordering Information KLM fuse panel cap Catalog Number Cap for KLM fuse panel KLM-CAP rear Covers Ordering Information Rear covers Catalog Number Input power terminal block cover PWX-rC ring Lug Kit Ordering Information Ring lug kit Catalog Number 100 Piece, 16-22 AWG rLK-001 20 Piece, 8 AWG rLK-002 20 Piece, 10 AWG rLK-003 w w w. a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1 38 ® 10/09 • 105203AE PowerWorx Power Distribution Products ® PowerWorx Accessories tPA Fuses – Alarm indicator Ordering Information TPA fuses - alarm indicator Catalog Number 3 Amps tPA-03 5 Amps tPA-05 10 Amps tPA-10 15 Amps tPA-15 20 Amps tPA-20 25 Amps tPA-25 30 Amps tPA-30 40 Amps tPA-40 50 Amps tPA-50 w w w. a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1 39 ® 10/09 • 105203AE PowerWorx Power Distribution Products ® PowerWorx ™ Advantage Series Accessories Carling Breakers and tPC Fuses/Fuse Holder Ordering Information Ordering Information Carling breakers Catalog Number TPC fuses/fuse holder Catalog Number 1 AMP CA1-X0-09-571-A21-MG 15 AMP tPC-15 10 AMP CA1-X0-09-572-A21-MG 20 AMP tPC-20 20 AMP CA1-X0-09-573-A21-MG 25 AMP tPC-25 30 AMP CA1-X0-09-574-A21-MG 30 AMP tPC-30 40 AMP CA1-X0-09-575-A21-MG 40 AMP tPC-40 50 AMP CA1-X0-09-576-A21-MG 50 AMP tPC-50 60 AMP CA1-X0-09-577-A21-MG 60 AMP tPC-60 75 AMP CA1-X0-09-578-A21-MG 75 AMP tPC-75 90 AMP CA1-X0-09-634-A21-MG 90 AMP tPC-90 100 AMP CA1-X0-09-635-A21-MG 100 AMP tPC-100 125 AMP tPC-125 tPC Fuse Holder tPCDS-BBe-2 w w w. a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1 40 ® 10/09 • 105203AE PowerWorx Power Distribution Products ® PowerWorx ™ Advantage Series Accessories Compression Lugs For two-Hole Stud-type input Power Connections Compression lugs provide a robust and reliable electro-mechanical connection. Ordering Information Catalog Number Compression lugs; ships two per pack 2 AWG CL-02M 1 AWG CL-01M 1/0 AWG CL-01M0 Compression Lug 2/0 AWG CL-02M0 3/0 AWG CL-03M0 4/0 AWG CL-04M0 250 KCMil CL-250M 300 KCMil CL-300M 350 KCMi CL-350M Miscellaneous Accessories Ordering Information Miscellaneous Accessories Catalog Number Circuit breaker fingerguards; ships 12 per pack FG-01A Circuit breaker/TPC fuse designation cards; ships 12 per pack DCK-01A *TPC fuse holder adapter; ships 12 per pack FHA-01A Input power terminal block cover PWX-AD-rC-in Output power terminal block cover PWX-AD-rC-oUt *required for mounting tPC fuse holder in Advantage Platform Designation Fingerguard Fingerguard TPC Fuse Output Power Input Power Card FG-01A FG-01A Holder Adapter Terminal Block Terminal Block DCK-01A (Front view) (Side view) FHA-01A Cover Cover PWX-AD-RC-OUT PWX-AD-RC-IN w w w. a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1 41 ® 10/09 • 105203AE PowerWorx Power Distribution Products Website: www.adc.com From North America, Call Toll Free: 1-800-366-3891 • Outside of North America: +1-952-938-8080 Fax: +1-952-917-3237 • For a listing of ADC’s global sales office locations, please refer to our website. ADC telecommunications, inc., P.o. Box 1101, Minneapolis, Minnesota USA 55440-1101 Specifications published here are current as of the date of publication of this document. Because we are continuously improving our products, ADC reserves the right to change specifications without prior notice. At any time, you may verify product specifications by contacting our headquarters office in Minneapolis. ADC telecommunications, inc. views its patent portfolio as an important corporate asset and vigorously enforces its patents. Products or features contained herein may be covered by one or more U.S. or foreign patents. An equal opportunity employer 105203AE 10/09 Revision © 2009, 2008, 2007 ADC Telecommunications, Inc. All Rights Reserved ® Powerworx Power Distribution ProDucts

Frequently asked questions

What makes Elite.Parts unique?

chervon down
At GID Industrial (Elite.Parts' parent company), we specialize in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

What kind of warranty will the PWX-001RGCSD10PWDP have?

chervon down
Warranties differ by part and by which suppliers we use to procure it for you. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carriers does Elite.Parts work with?

chervon down
Elite.Parts can ship via FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Will Elite.Parts sell to me even though I live outside the USA?

chervon down
Absolutely! We are happy to serve customers regardless of location. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

I have a preferred payment method. Will Elite.Parts accept it?

chervon down
All major credit cards are accepted: Visa, MasterCard, Discover, and American Express. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

4-port midspan Power-over-Ethernet set-top unit

Carling Breaker, 1 Amp

Carling Breaker, 10 Amp

Carling Breaker, 20 Amp

ADC CA1-X0-09-574-A21-MG CIRCUIT BREAKER 30AMP CA1-X0-09-574-A21-MG ADC

Carling Breaker, 40 Amp