ACROMAG 250T-TC1-DIN-NCR

Description
ACROMAG 250T-TC1-DIN-NCR Transmitter, 12 to 50V DC @ 20mA (loop-power) power; thermocouple input, field-selectable; DIN rail G or T mount; no certification/approval required
Part Number
250T-TC1-DIN-NCR
Price
Request Quote
Manufacturer
ACROMAG
Lead Time
Request Quote
Category
PROCESS INSTRUMENT
Datasheet
Extracted Text
Flat Pack Series 250T Loop-Powered (2-wire) Transmitter PLC / DCS Isolated Transmitters P + S Sense Resistor 250T + IN OUT – + 24V DC 4-20mA RLOAD Input L – Isolation 350T DC-Powered (3-wire) Transmitter PLC / DCS P + P 350T PWR + IN – + 24V DC OUT V/mA RLOAD Input – L – Isolation 450T AC-Powered (4-wire) Transmitter PLC / DCS Thermocouple + S Sense Resistor Input 450T + OUT + – – IN V/mA These models convert sensor inputs to propor- L1 3-Way PWR RLOAD W – tional process current or voltage output signals. L Isolation G Models 250T: Loop-powered transmitter series ■Special Features■Performance 350T: DC-powered transmitter series Ambient Temperature Range■Excellent accuracy and stability ensure reliable 450T: AC-powered transmitter series Operating: -13 to 185°F (-25 to 85°C). measurements in harsh industrial environments. Storage: -40 to 185°F (-40 to 85°C). Input Ranges■Field-selectable input types reduce stocking Accuracy ■Thermocouple types J, K, T, R, S, E, B ±0.1% of calibrated span or ±0.01mV, whichever is requirements. greater. Includes repeatability, hysteresis, terminal ■Linearized thermocouple (custom ranges)■Thermocouple reference junction compensa- point linearity, and adjustment resolution. tion reduces drift and corrects nonlinearity. Ambient Temperature Effect Output Ranges Less than ±0.01% of output span per °F (±0.018% per ■TC linearizer (5-slope) improves accuracy. ■DC current: 4 to 20mA °C). ±0.025% of output span per °F (±0.045% per °C) for narrow span units. (Specification includes the com- ■TC break detection indicates open circuit fail- ■DC voltage: 0 to 5V or 0 to 10V bined effects of zero and span over temperature). ures with selectable up/downscale operation. Noise Resistance Power Requirements RFI: Less than ±0.5% ,of output span effect.■RFI and EMI resistance minimize the effects of ■250T: 12 to 50V DC @ 20mA (loop-powered) EMI: Less than ±0.25% of output span effect. environmental noise. Noise Rejection ■350T: DC voltage source (see table below) ■75% span adjustment enables precise Common Mode: 130dB at 60Hz, 100 ohm unbalance. application calibration. Normal Mode: 30dB at 60Hz, 100 ohm source. Output range Power 4 to 20mA 10 to 36V DC @ 30mA Response Time ■1500V AC peak isolation (250V AC or 354V Output reaches 98% of output span in 300mS. 0 to 5V 10 to 36V DC @ 9mA DC continuous) prevents ground loops. Bandwidth 0 to 10V 12.5 to 36V DC @ 9mA -3dB at 3 Hz, typical. 250T models: ■450T: 115V or 230V AC, ±10%, 50 to 60Hz Output Compliance Input isolated from output/power. 250T: RLOAD (max.) = (VSUPPLY - 12V) / 20mA. Output range Power 350T models: 350T: RLOAD (max.) = (VSUPPLY - 2.5V) / 20mA. 4 to 20mA 115V AC @ 0.050A 450T: RLOAD = 600 ohms. Input isolated from output and power. 4 to 20mA 230V AC @ 0.025A Output and power share a common. Linearization (-xLxx) Option 0 to 5V, 0 to 10V 115V AC @ 0.020A 5-segment TC linearizer provides minimum 10 to 1 450T models: 0 to 5V, 0 to 10V 230V AC @ 0.010A improvement ±0.1% in the linearity curve. 3-way isolation. Input, output, and power circuits are isolated from each other. Tel: 248-624-1541 Fax: 248-624-9234 e-mail: sales@acromag.com www.acromag.com 124 Flat Pack Flat Pack Isolated Transmitters Power Options (450T only)■Ordering Information -1: 115V AC power Select one option from each column. Example: 450T-TC3-Y-1-DIN-NCR-C -2: 230V AC power To order factory calibration, append “-C” to end of model number. Specify ranges on order. Mounting Options Base Input Mounting Approval Mountings 250T -TC1 -RL00* -DIN -N4 -NCR -DIN: DIN rail G or T mount -TC3* -SL00* -ST -N12 -OL1 -ST: SNAPTRACK mount [250T only] Note: -JL00* -EL00* -SM -XP -DT1 All 250Ts have 4 to 20mA output -SM: Surface-mount [250T only] -KL00* -BL00* -EP1 and are loop-powered. External housings -TL00* -IS1 -N4: NEMA 4, water-tight [250T only], holds two -N12: NEMA 12, oil-tight [250T only], holds two Base Input Output Mounting Approval -XP: Explosion-proof NEMA 4 [250T only], holds one 350T -TC1 -RL00* -Y -DIN -NCR Approval Options Note: -TC3* -SL00* -V0 All 350Ts accept -NCR: No certification/approval required. -JL00* -EL00* -V5 10 to 36V DC † -OL1 : CSA approval, Ordinary Locations [250T only]. -KL00* -BL00* power supply. † -DT1 : CSA approval, Div. 2 hazardous locations: -TL00* Class I; Div. 2; Groups A, B, C, D [250T only]. †† -EP1 : CSA approval, Explosion-proof for hazardous Base Input Output Power Mounting Approval locations: Class I; Groups B, C, D Class II; Groups E, 450T -TC1 -RL00* -Y -1 -DIN -NCR F, G. NOTE: Only available with explosion-proof housing (-XP) [250T only]. -TC3* -SL00* -V0 -2 † -IS1 : CSA approval, Intrinsically Safe for hazardous -JL00* -EL00* -V5 locations: Class I; Groups A, B, C, D. -KL00* -BL00* [250T only]. -TL00* Input Options Linearized Input Options ■Ordering Notes (output linear to temperature for spans over 5mV Nonlinearized Input Options * Unit requires factory calibration. Append “-C” to consult factory for spans under 5mV) (output linear to millivolts) end of model number. Specify ranges on order. -JL00*: Linearized TC for Type J -TC1: Thermocouple; † Units are shipped separately from any optional Specify ranges on order. Field-selectable for J,K,T,R,S,E,B enclosures (i.e. units are not installed in any external -KL00*: Linearized TC for Type K housing). Type J: Specify ranges on order. Span: 100 to 760°C (180 to 1368°F) †† Units shipped installed in external enclosure. -TL00*: Linearized TC for Type T Zero: -100 to 450°C (-148 to 842°F) Specify ranges on order. Accessories Type K: -RL00*: Linearized TC for Type R Span: 100 to 1200°C (180 to 2160°F) Power supplies Specify ranges on order. Zero: -100 to 600°C (-148 to 1112°F) See Power Supplies on page 183. -SL00*: Linearized TC for Type S Type T: DIN RAIL 3.0 Specify ranges on order. Span: 150 to 400°C (270 to 720°F) DIN RAIL 16.7 Zero: -150 to 300°C (-238 to 572°F) -EL00*: Linearized TC for Type E DIN rail strip, Type T, 3 inches (75mm) or Specify ranges on order. 16.7 inches (425mm) Type E: Span: 100 to 700°C (180 to 1260°F) -BL00*: Linearized TC for Type B 20RM-16-DIN Zero: -100 to 350°C (-148 to 662°F) Specify ranges on order. 19" rack-mount kit with DIN rail. Holds sixteen 250T/350Ts or ten 450T transmitters. Type R: Input Impedance Span: 550 to 1750°C (990 to 3150°F) Without TC Break Detection: 1.0M ohm at 10mV 350T-N4-WM Zero: 0 to 1200°C (32 to 2192°F) span, typical; input current, ±10nA, typical. NEMA 4 water-tight enclosure, wall-mount. Holds two 350Ts or one 450T transmitter. Type S: With TC Break Detection: 400K ohm at 10mV span; Span: 550 to 1750°C (990 to 3150°F) input current, ±25nA, typical (±30nA, max.). 350T-N12-WM Zero: 0 to 1200°C (32 to 2192°F) NEMA 12 oil-tight enclosure, wall-mount. Holds two Output Options (350T, 450T only) 350Ts or one 450T transmitter. Type B: -Y: 4 to 20mA DC. Span: 1000 to 1820°C (1800 to 3276°F) Zero: 0 to 1000°C (32 to 2192°F) -V0: 0 to 10V DC into 10K ohms or greater -TC3*: Narrow span TC, Field selectable J,K,T,R,S,E,B; -V5: 0 to 5V DC into 5K ohms or greater (spans from 3 to 5mV ); . Specify ranges on order. Tel: 248-624-1541 Fax: 248-624-9234 e-mail: sales@acromag.com www.acromag.com 125 Flat Pack Series Dimensions Transmitters: 250T, 350T Isolators: 270i, 340i, Limit Alarms: 260A Power Supplies: 25PS, 35PS-2U Surface Mount: Snaptrack 250T-SM, Mount: 260A-SM, 250T-ST, 270i-SM, 260A-ST, 25PS-SM 270i-ST, 25PS-ST Dimensions are in inches (millimeters). Tel: 248-624-1541 Fax: 248-624-9234 e-mail: sales@acromag.com www.acromag.com 138 Flat Pack Flat Pack Signal Conditioners Dimensions Explosion-Proof and Industrial Housing 250T-XP, 260A-IH/IHW, 270i-XP 250T Transmitter shown installed in enclosure with cover removed. 250T Transmitter shown removed from enclosure. NEMA-4 and NEMA-12 Enclosures 250T-N4 / N12, 25PS-N4 / N12 260A-N4 / N12, 270i-N4 / N12 Dimensions are in inches (millimeters). Tel: 248-624-1541 Fax: 248-624-9234 e-mail: sales@acromag.com www.acromag.com 139 Flat Pack Series Dimensions Transmitters: 450T Isolators: 330i, 430i, Limit Alarms: 361A, 461A Power Supplies: 35PS-8U NEMA-4 and NEMA-12 Enclosures 350T-N4-WM 350T-N12-WM Dimensions are in inches (millimeters). Tel: 248-624-1541 Fax: 248-624-9234 e-mail: sales@acromag.com www.acromag.com 140 Flat Pack Flat Pack Signal Conditioners Dimensions 20RM-16-DIN Rack Mount Kit AC Sensor 5020-350 Dimensions are in inches (millimeters). Tel: 248-624-1541 Fax: 248-624-9234 e-mail: sales@acromag.com www.acromag.com 141
Frequently asked questions
What makes Elite.Parts unique?

What kind of warranty will the 250T-TC1-DIN-NCR have?

Which carriers does Elite.Parts work with?

Will Elite.Parts sell to me even though I live outside the USA?

I have a preferred payment method. Will Elite.Parts accept it?

What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods