ACME PORTABLE TA-2-32406

Description
Acme Electric TA-2-32406 240/416/480/600; 230/400/460/575; 220/380/440/550 Primary Volts; 99/120/130; 95/115/125; 91/110/120; 85/100/110 Secondary Volts; Industrial Control Transformers
Part Number
TA-2-32406
Price
Request Quote
Manufacturer
ACME PORTABLE
Lead Time
Request Quote
Category
PRODUCTS - T
Datasheet
Extracted Text
INDUSTRIAL CONTROL TRANSFORMERS SECTION GROUP F 380/440/550/600 PRIMARY VOLTS —115/230 SECONDARY VOLTS — 50/60 Hz CATALOG VA OUTPUT APPROX. DIMENSIONS APPROX. PRIMARY SECONDARY SECONDARY Inches (Cm.) AMPS NO. RATING SHIP WEIGHT FUSE BLOCK FUSE KIT 0,' FUSE SIZE CD A B C D E F IDs. (Kg.) Part No. Part No. 115 VOLTS TA-2-54535 0.43 50 4.12 3.75 3.21 3.13 2.19 .22 x .50 4 PL-112701 PL-112600 6/io amp (10.5) (9.5) (8.2) (8.0) (5.6) (0.6x1.3) (1.8) TA-2-54536 100 0.87 4.56 3.75 3.21 3.13 2.31 .22 x .50 5 PL-112701 PL-112600 1 1/4 amps (11.6) (9.5) (8.2) (8.0) (5.9) (0.6x1.3) (2.3) TA-2-54537 150 1.30 5.00 3.75 3.21 3.13 3.06 .22 x .50 10 PL-112701 PL-112600 2 amps (12.7) (9.5) (8.2) (8.0) (7.8) (0.6x1.3) (4.5) 1 1 TA-2-54538 250 2.17 5.49 4.50 3.84 3.75 3.50 .22 x .50 PL-112702 PL-112601 3'/2 amps (13.9) (11.4) (9.8) (9.5) (8.9) (0.6x1.3) (5.0) TA-2-81197 3.04 350 6.03 4.88 4.15 4.06 4.38 .22 x .50 17 PL-112703 PL-112601 5 amps (15.3) (12.4) (10.5) (10.3) (11.1 ) (0.6x1.3) (7.7) TA-2-54539 500 4.35 6.76 4.88 4.15 4.06 5.75 .22 x .50 23 PL-112703 PL-112601 7 amps (17.1) (12.4) (10.5) (10.3) (14.6) (0.6x1.3) (10.4) TA-2-81240 750 6.52 7.19 6.75 5.72 5.75 3.69 .31 x .50 25 PL-112705 PL-112601 10 amps (18.3) (17.1 ) (14.5) (14.6) (9.4) (0.8x1.3) (11.3 ) TA-2-81241 1000 8.70 7.77 6.75 5.72 5.75 4.44 .31 x .50 30 PL-112705 PL-112601 12 amps (19.7) (17.1) (14.5) (14.6) (11.3) (0.8x1.3) (13.6) GROUP G 240/416/480/600; 230/400/460/575; 220/380/440/550; 208/500 PRIMARY VOLTS 99/120/130; 95/115/125; 91/110/120; 85/100/110 SECONDARY VOLTS — 50/60 Hz APPROX. DIMENSIONS PRIMARY SECONDARY SECONDARY CATALOG VA OUTPUT APPROX. Inches (Cm.) SHIP WEIGHT FUSE BLOCK FUSE KIT ' FUSE SIZE NO. RATING AMPS Lbs.(Kg.) Part No. Part No. 130 VOLTS A B C D E F PL-112600 6/io amp TA-2-32403 50 0.38 4.08 3.75 3.21 3.13 2.31 .22 x .50 5 PL-112701 (10.4) (9.5) (8.2) (8.0) (5.9) (0.6x1.3 ) (2.3) TA-2-32404 150 1.1 5 4.75 4.50 3.84 3.75 3.05 .22 x .50 10 PL-112702 PL-112601 16/ioamps (12.1) (11.4) (9.8) (9.5) (7.7) (0.6 x 1 .3) (4.5) TA-2-32405 250 1.92 5.58 4.88 4.15 4.06 4.06 .22 x .50 1 6 PL-112703 PL-112601 32/ioamps (14.2) (12.4) (10.5) (10.3) (10.3) (0.6 x 1.3) (7.3) TA-2-32669 350 2.69 6.23 4.88 4.15 4.06 5.50 .22 x .50 22 PL-112703 PL-112601 4 amps (15.8) (12.4) (10.5) (10.3) (14.0) (0.6x1.3) (10.0) TA-2-32406 500 3.85 6.40 6.75 5.72 5.75 3.69 .22 x .50 23 PL-112705 PL-112601 61/4amps (16.3) (17.1 ) (14.5) (14.6) (9.4) (0.6x1.3) (10.4) TA-2-54523 750 5.77 7.08 6.75 5.72 5.75 4.13 .31 x .50 29 PL-112705 PL-112601 9 amps (18.0) (17.1) (14.5) (14.6) (10.5) (0.8x1.3) (13.2) TA-2-54524 1000 7.69 8.56 6.75 5.72 5.75 4.88 .31 x.50 35 PL- 11 2705 PL-112601 12 amps (21.7) (17.1 ) (14.5) (14.6) (12.4) (0.8x1.3) (15.9) TA-2-54525 1500 11.54 6.75 7.50 7.66 6.50 5.42 .41 x .81 55 PL-112706 PL-112601 20 amps (17.1) (19.1 ) (19.5) (16.5) (13.8) (1.0x2.1 ) (24.9) TA-2-81202 2000 15.39 7.45 7.50 7.66 6.50 6.12 .41 x.81 55 PL-112706 PL-112601 25 amps (18.9) (19.1 ) (19.5) (16.5) (15.5) (1.0x2.1 ) (24.9) TA-2-81203 3000 23.08 7.02 11.92 8.83 6.75 5.75 .41 x .81 70 PL-112707 — — (30.3) (22.4) (17.1) (1.0x2.1) (31.8) (17.8) (14.6) TA-2-81205 5000 38.46 7.52 11.9 2 6.75 6.25 .41 x .81 11 0 PL-112707 — 9.49 — (30.3) (24.1) (17.1 ) (1.0x2.1 ) (49.9) (19.1 ) (15.9) CONNECTION DETAILS FOR GROUP G Connect To Line For Respective Voltage Output Volts H1-H4 H1-H5 X1-X2 X1-X3 X1-X4 H1-H2 H1-H3 208 — — 500 85 100 11 0 380 440 550 91 11 0 120 220 230 400 460 575 95 11 5 125 240 416 480 600 99 120 130 C'.> Secondary Fuse Kit PL-112603 may be substituted for PL-112600 thru PL-112602 when Primary Fuse Kit is used. See page 65. © Secondary fuse kit application for 115V only. 61 INDUSTRIAL CONTROL TRANSFORMERS SECTION Industrial Control Transformers Industrial control transformers are used to reduce supply voltages to 230 V or lower for the operation of electromagnetic devices such as contactors, solenoids, relays, and timers. They are especially designed to accommodate the momentary current inrush caused when electro- magnetic components are energized ... without sacrificing secondary voltage stability beyond practical limits. Acme Industrial Control Transformers are dry-type, step-down transformers with Jumper Link Connections the secondary control circuit isolated from Primary Fuse Kit with Snap-on Secondary Fuse Block the primary line circuit to assure maxi- mum safety. Voltage regulation of Acme Industrial Control Transformers exceeds standards recommended by the National Electrical Manufacturers Association. Secondary circuit voltage drop between no-load and momentary overload remains exception- ally low. This excellent secondary circuit voltage regulation assures reliable oper- ation of electromagnetic components and may permit the use of a smaller and less expensive industrial control transformer. Secondary Fuse Clips Integrally Mounted Fuse Blocks Coils — Precision wound by machine; Sizing Primary Fuses: Acme Industrial total turns per coil automatically counted. Primary Amps<2, fuse size is 300% Control transformers of rated primary current Terminals — Copper-alloy terminals Primary Amps 2<9, fuse size is Meet or Exceed UL are soldered to coil leads. "Quick 167% of rated primary current CSA, NEMA and ANSI Connects" are available on 50-150 VA Primary Amps >9, fuse size is units. Acme Industrial Control Transformers 125% of rated primary current. 50 through 5000 VA are UL Listed, File Mounting — Heavy steel mounting Sizing Secondary Fuses: E79947 and CSA certified, File 7357. plates add strength to core construction Secondary Amps <9, fuse size is and provide firm mounting, slotted to Laminations — High-permeability 167% of rated secondary current facilitate installation. silicon steel continuously annealed to Secondary Amps >9, fuse size is minimize core losses. Terminal Boards - Sturdy phenolic 125% of rated secondary current. terminal boards. Magnet Wire — Copper magnet wire is coated with high temperature-resisting insulating film. EPOXETRAN Encapsulated Control Transformers. See Pages 68-69 in this section. 56 INDUSTRIAL CONTROL TRANSFORMERS SECTION Features 1. Constructed with high quality silicon 5. Sturdy phenolic terminal panel 9. Mounting plate adapts to various protects the coil from foreign mounting dimensions. steel lamination to minimize core losses and increase efficiency. objects and mechanical damage. 10. Voltage regulation exceeds Copper windings on all groups. 2. Designs incorporate precision 6. NEMA requirements. wound coils for improved regulation, y 11. UL Listed, CSA Certified. 130° C Insulation class. 80° C 3. Primary fuse blocks and secondary temperature rise. 12. Attractive finish, nameplate, and fuse kits available and easily g_ design features enhance the end Wire retention on both primary adaptable. product. and secondary terminals. 4. Series-parallel connecting links save wiring and labor costs. Integrally Mounted Fuse Blocks Add Suffix Configuration To Catalog No. A^fcN^1 (See Chart) -F2 Integrally mounted 2-pole primary block GROUP 'A' THROUG H 500 VA Integrally mounted 3-pole primary and secondary block -F3 GROUP'B' THROUGH 1000 VA Consult factory for other sizes available. Specifications and Dimensions GROUP A 120 X 240 PRIMARY VOLTS — 24 SECONDARY VOLTS — 50/60 Hz APPROX. DIMENSIONS CATALOG VA OUTPUT APPROX. PRIMARY SECONDARY SECONDARY Inches (Cm.) FUSE KITS NO.® RATING AMPS SHIP WEIGHT FUSE BLOCK FUSE SIZE Lbs.(Kg.) A B C D E F Part No. Part No. 24 VOLTS TA-2-81141 " 50 2.08 4.23 3.00 2.59 2.50 2.13 .22 x .50 4 PL-112700 PL-112602 32/io amps (10.7) (7.6) (6.6) (6.4) (5.4) (0.6x1.3) (1.8) TA-2-81142© 75 3.13 4.74 3.00 2.59 2.50 2.61 .22 x .50 4 PL-112700 PL-112602 Samps (12.0) (7.6) (6.6) (6.4) (6.6) (0.6x1.3) (1.8) PL-112602 TA-2-81143 2i 100 4.17 4.90 3.00 2.59 2.50 2.81 .22 x .50 4 PL- 11 2700 61/4 amps (12.4) (7.6) (6.6) (6.4) (7.1) (0.6x1.3) (1.8) TA-2-81144® 150 6.25 4.78 3.75 3.21 3.13 2.63 .22 x .50 6 PL-112701 PL-112602 10 amps (12.1) (9.5) (8.2) (8.0) (6.7) (0.6x1.3) (2.7) TA-2-81146 - 250 10.42 5.08 4.50 3.84 3.75 3.05 .22 x .50 9 PL-112702 PL-112601 15 amps (12.9) (11.4 ) (9.8) (9.5) (7.7) (0.6x1.3) (4.1) 350 14.58 6.12 4.50 3.84 3.75 4.06 .22 x .50 13 PL-112702 PL-112601 20 amps TA-2-81148® (15.5) (11.4) (9.8) (9.5) (10.3) (0.6x1.3) (5.9) TA-2-81149 > 500 20.83 5.90 5.25 4.47 4.38 4.19 .31 x .50 1 6 PL- 11 2704 PL-112601 30 amps (15.0) (13.3) (11.4 ) (11.1 ) (10.6) (0.8x1.3) (7.3) TA-2-81150 750 31.25 7.53 5.25 4.47 4.38 5.25 .31 x .50 24 PL-112704 — — (19.1) (13.3) (11.4) (11.1 ) (13.3) (0.8x1.3) (10.9) TA-2-81151 1000 41.67 7.43 6.75 5.72 5.75 3.81 .31 x .50 26 PL-112705 — — (18.9) (17.1 ) (14.5) (14.6) (9.7) (0.8x1.3) (11.8 ) 240 X 480, 230 X 460, 220 X 440 PRIMARY VOLTS — 120/115/110 SECONDARY VOLTS — 50/60 Hz APPROX. DIMENSIONS SECONDARY SECONDARY CATALOG VA OUTPUT APPROX. PRIMARY Inches (Cm.) SHIP WEIGHT FUSE BLOCK FUSE KIT® NO.® RATING AMPS FUSE SIZE 120 VOLTS A B C D E F Lbs.(Kg.) Part No. Part No. PL-112602 TA-2-81210* 50 0.42 4.23 3.00 2.59 2.50 2.13 .22 x .50 4 PL-112700 6/io amp (5.4) (10.7) (7.6) (6.6) (6.4) (0.6x1.3) (1.8) 2.61 4 PL-112700 PL-112602 1 amp TA-2-81201 © 75 0.63 4.74 3.00 2.59 2.50 .22 x .50 (0.6x1.3) (12.0) (7.6) (6.6) (6.4) (6.6) (1.8) 0.83 3.00 2.59 2.50 2.81 .22 x .50 4 PL-112700 PL-112602 11/4amps TA-2-81211 = 100 4.90 (12.4) (7.6) (6.6) (6.4) (0.6x1.3) (7-1) (1.8) 1.25 5.00 3.75 3.21 3.13 2.81 .22 x .50 6 PL-112701 PL-1 1 2602 2 amps TA-2-81212® 150 (12.7) (7.1) (0.6x1.3) (2.7) (9.5) (8.2) (8.0) 250 2.08 5.57 4.50 3.84 3.75 3.13 .22X.50 9 PL-112702 PL-112601 3 2/i o amps TA-2-81213® (14.1 ) (9.8) (9.5) (8.0) (0.6x1.3) (4.1) (11.4 ) CD Secondary Fuse Kit PL-112603 may be substituted for PL-112600 thru PL-112602 when Primary Fuse Kit is used. See page 65. © See chart for integrally mounted fuse block catalog number suffix. 58 INDUSTRIAL CONTROL TRANSFORMERS SECTION Industrial Control Electrical Connection Diagrams Group A Group B Group C Group D 480V 240V H1 H2 H3 H4 460 230 600V m He 240V 120V i 440 I! 220 i 575 • 480V ——————————— • 1 . _ . | | _ . . _ 1 550 480V H1 H3 H2 H4 H1 H3 H2 H4 H1 H3 H2 H4 H1 H3 H2 H4 - 460 277V ' H4 440 H1 H3 H2 H4 H1 H3 H2 H4 240V £."-t\j v no - 230 • 220 y y 208V -|H2 jUJUJUUUoUk. AAXXAAXXAJJOUJUUolJUJUuLuL A-L. AA. AJJJJJJUJUUL/ \JUJUJUOAJJuJ UUUJUUUUJULX/ VUUUJUUUUOJL TYYYYYYYYYTYY" rrrr- prrrrrrrmmrrmrrri ^•YrrrrYvvrrrYrrYYVTnnnrnnnr 100V 95 24V X 2 90 120V X2 X1 • ————— 115 120V 11 0 115 ———— - X2 X1 X2 X1 11 0 X3 X1 Group E Group F Group G Group H 2 H3 H4 h5 H1 H2 H3 H4 m H m MS 600V 600V H1 H4 575 - ————— - 380V - - ——— 550V - — - H4 480V 550 - —————— 460V - —— 460 • 500 440V • H3 277V • 416V 440 - 380V • H2 400 ' 240V • 208V • 380 - 208V • H2 nrmnmpmrrx rrrrrrrrrrrn JJU-J-AJ- JU~UU_ JUJUJOL JU-U^OUJkAxLuUUUJUUJUL JUUAAJLJUL TYYT- YYYYYYY^r rnrmnrmnnprnnprnn A 95V X4 X2 X3 X1 99V X2 . 95 . I— 115V X4 X2X3 X1 X4 X2 X3 XI 120V 91 X2 X1 115 85 115 V 11 0 230V 115V 130V X3 X1 100 125 120 11 0 X4 X 3 X2 X1 Group I Group J Group K 2 480V 240V H1 H H1 H2 H1 H3 H2 H4 H1 H3 H2 H4 - ——— 600V 600V ————— - H1 H3 H2 H4 y AJULJUUUJUUUUUJUUUUUUUUUJJUL JUUUJUJUUUUUUUUUUL JUOUUUUUU LjLXAAAJUoUuUL/ XJJLAjUJUJU^uJ pnmmrmrrr\ /-nnmmnmrri nnnmmmTT\ onmnnmnnnn pnrrrTYYrrrrx rrrrrcrrrrrr\ A A X4 X2 X3 X1 A X4 X2 X3 X yA YP YT Y1 Yd Y9 YT Y1 X4 X2 X3 X1 X4 X2 X3 X X4 X2 X3 X1 X4 X2 X3 XI i r n 24V 12V 240V 120V 240V 120V Dimensions 50VAThru2KVA 3 & 5 KVA o o o 66
Frequently asked questions
What makes Elite.Parts unique?

What kind of warranty will the TA-2-32406 have?

Which carriers does Elite.Parts work with?

Will Elite.Parts sell to me even though I live outside the USA?

I have a preferred payment method. Will Elite.Parts accept it?

What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods